PCR evaluation of false-positive signals from two automated blood-culture systems.

Rapid detection of micro-organisms from blood is one of the most critical functions of a diagnostic microbiology laboratory. Automated blood-culture systems reduce the time needed to detect positive cultures, and reduce specimen handling. The false-positive rate of such systems is 1-10%. In this study, the presence of pathogens in 'false-positive' bottles obtained from BACTEC 9050 (Becton Dickinson) and BacT/Alert (Biomérieux) systems was investigated by eubacterial and fungal PCR. A total of 169 subculture-negative aerobic blood-culture bottles (104 BacT/Alert and 65 BACTEC) were evaluated. Both fungal and eubacterial PCRs were negative for all BACTEC bottles. Fungal PCR was also negative for the BacT/Alert system, but 10 bottles (9.6%) gave positive results by eubacterial PCR. Sequence analysis of the positive PCR amplicons indicated the presence of the following bacteria (number of isolates in parentheses): Pasteurella multocida (1), Staphylococcus epidermidis (2), Staphylococcus hominis (1), Micrococcus sp. (1), Streptococcus pneumoniae (1), Corynebacterium spp. (2), Brachibacterium sp. (1) and Arthrobacter/Rothia sp. (1). Antibiotic usage by the patients may be responsible for the inability of the laboratory to grow these bacteria on subcultures. For patients with more than one false-positive bottle, molecular methods can be used to evaluate the microbial DNA in these bottles. False positives from the BACTEC system may be due to elevated patient leukocyte counts or the high sensitivity of the system to background increases in CO(2) concentration.

Adult↗

A method for the automated mapping of laboratory results to LOINC.

LOINC is emerging as the standard for laboratory result names, and there is great interest in mapping legacy terms from laboratory systems to it. However, the mapping task is non-trivial, requiring significant resource commitment and a good understanding of the LOINC identifying attributes for the laboratory result names. Because the number of results in a laboratory system may range from around 500 to 2000 or more, manual, one-by-one matching, even with the aid of the RELMA matching tool provided by LOINC, is time consuming and laborious. Moreover, human variation may introduce mapping inconsistencies or errors. Through our experience mapping the results from a variety of laboratory systems to LOINC, an automated mapping method has been developed and is described in this paper. This method allows for data from the laboratory information system to be provided in a manner familiar to the submitting technician, and makes use of parsing and logic rules, combined with synonyms, attribute relationships and mapping frequency data, to perform automated matching to LOINC.

Classification↗

[Perspective for clinical laboratory management and its systematization--effects of the systematization of clinical laboratory management].

There are a large number of ideas concerning the systematization of clinical laboratory management. Therefore many types of laboratory systems have been constructed. As our hospital is not large, we adopted a small scale laboratory system. In introducing it, we expected not only an increase in value-added labor productivity by automating laboratory tests, but also an improvement in technologist's cost awareness. Consequently, new system equipment has itself performed the former in many sections, but not the latter. Improvement in cost awareness was caused by the technologist's routine work in managing reagent and material stocks. We found that this soft-type systematization has been more important than the advanced hard-type system.

Awareness↗

[Hemostasis screening in the emergency laboratory].

PURPOSE: While automation of laboratories is of great value for analysts, as it makes technical work easier, and for clinicians, as the results are available in a shorter time, the requests increase strikingly bringing about higher costs. The emergency laboratory is an example of what happens in the general laboratory. In order to make an estimate of this subject, the haemostasis screening was chosen since it is a recently automated technique in that laboratory, attention being paid to the aim and indication of the screening and its economical burden. MATERIAL AND METHODS: A study of the haemostasis screening performed during July 1990 was carried out of considering the 24 hours per day work. The requests were classified, in accordance with their indication, as diagnostic, pre-surgical, therapeutic or unknown; the justification and purpose of those requests was also examined. RESULTS: The total number of studies performed in that month was 1,273, with a daily mean of 41, as opposed to 2,095 performed in the haemostasis laboratory in the same period. According to the American Medical Association criteria only 48% of the requests could be warranted, and abnormal findings appeared in only 10% of them. CONCLUSIONS: The cost per isolated parameter is low, but it increases greatly when compared with the benefit that it reports to the patient because, as those biological tests indirectly measure the concentration of clotting factors, they are subjected to error when performed by non-specialized personnel; on the other hand, the most valuable information for detecting haemorrhagic troubles comes from the patient's history. The economical burden in the month studied amounted to 985,879 PTA; one year later, the same laboratory, in the same month, had a 50% increase of studies.

Blood Coagulation Disorders↗

Robotic production of 2-deoxy-2-[18F]fluoro-D-glucose: a routine method of synthesis using tetrabutylammonium [18F]fluoride.

Using existing robotic hardware and software programs developed for the synthesis of several positron-emitting radiopharmaceuticals for PET imaging [Brodack et al. (1988) Appl. Radiat. Isot. 39, 689], the additional automated synthesis of 2-deoxy-2-[18F]fluoro-D-glucose (2-[18F]FDG) has been incorporated into our Zymate Laboratory Automation System. The robotic synthesis of 2-[18F]FDG took less than one week to implement, including the organization of software subroutines and construction of an additional heating station. The end of synthesis yield (12-17%) and radiochemical purity (96-99%) for the robotic preparation of 2-[18F]FDG is similar to that of the manual synthesis. This automated method uses anhydrous tetrabutylammonium [18F]fluoride as the reactive fluoride source in the labeling step. The procedure is a modification of the synthesis reported by Hamacher et al. [Hamacher et al. (1986) J. Nucl. Med. 27, 235].

Deoxy Sugars↗

Comparison of point-of-care versus central laboratory measurement of electrolyte concentrations on calculations of the anion gap and the strong ion difference.

BACKGROUND: Clinicians calculate the anion gap (AG) and the strong ion difference (SID) to make acid-base diagnoses. The technology used is assumed to have limited impact. The authors hypothesized that different measurement technologies markedly affect AG and SID values. METHODS: SID and AG were calculated using values from the point-of-care blood gas and electrolyte analyzer and the central hospital laboratory automated blood biochemistry analyzer. Simultaneously measured plasma sodium, potassium, and chloride concentrations were also compared. RESULTS: Mean values for central laboratory and point-of-care plasma sodium concentration were significantly different (140.4 +/- 5.6 vs. 138.3 +/- 5.9 mm; P < 0.0001), as were those for plasma chloride concentration (102.4 +/- 6.5 vs. 103.4 +/- 6.0 mm; P < 0.0001) but not potassium. Mean AG values calculated with the two different measurement techniques differed significantly (17.6 +/- 6.2 mEq/l for central laboratory vs. 14.5 +/- 6.0 mEq/l for point-of-care blood gas analyzer; P < 0.0001). Using the Stewart-Figge methodology, SID values also differed significantly (43.7 +/- 4.8 vs. 40.7 +/- 5.6 mEq/l; P < 0.0001), with mean difference of 3.1 mEq/l (95% limits of agreement, -3.4, 9.5 mEq/l). For 83 patients (27.6%), differences in AG values were as high as 5 mEq/l or more, and for 46% of patients whose AG value was outside the reference range with one technology, a value within normal limits was recorded with the other. CONCLUSIONS: Results with two different measurement technologies differed significantly for plasma sodium and chloride concentrations. These differences significantly affected the calculated AG and SID values and might lead clinicians to different assessments of acid-base and electrolyte status.

Chlorides↗

Laboratories in patient-centered units.

As part of a hospital pilot project evaluating decentralized patient-focused care, a new laboratory model was studied. Cross-trained personnel (nurses, medical technologists, radiology technologists, and respiratory therapists) performed high-volume, automated laboratory tests in a unit-based laboratory as part of their overall patient care duties. Testing performed in the patient-centered unit laboratory, in general, was comparable in quality to that reported by the hospital's central laboratory.

Academic Medical Centers↗

Automated synthesis and combinatorial chemistry.

The advent of combinatorial chemistry for the high-throughput synthesis of compounds has driven the advancement of new and emerging technologies for synthetic chemistry laboratories. Automated methods for reaction design, information management, chemical synthesis, compound analysis, and biological testing are necessary to realize the full potential of combinatorial chemistry efforts.

Journal Article↗

Phlebotomy issues and quality improvement in results of laboratory testing.

Laboratory testing is an integral part of the decision-making process, and results of laboratory testing often strongly influence medical diagnoses and therapies. There is a long history of quality requirements in laboratory medicine, which have mainly concerned the analytic phase of this process. Owing to the substantial advances in technology, laboratory automation and analytic quality, there is increasing evidence that further quality improvements should be targeted to extra-analytic phases of laboratory testing. Objective difficulties to monitor most of the preanalytic variables which lie outside the direct control or supervision of the laboratory personnel, such as phlebotomy, call for effective educational and preventive policies. Owing to high personnel turnover rates, lack of understanding about good laboratory practices, and inadequate training, there are several opportunities for making errors during phlebotomy, which mainly concern patient misidentification and collection of unsuitable specimens for testing due to unsuited venous accesses, venous stasis, inappropriate collection devices and containers. Improved standardization of phlebotomy techniques, along with operative guidelines dissemination, continuous education, certification, and training of health care professionals involved in blood drawing responsibilities would enhance the chance of obtaining specimens of consistent quality, with favorable revenues for the health care system and the patient's outcome.

Bloodletting↗

Peripheral blood film review. The demise of the eyecount leukocyte differential.

The automated hematology analyzer with CBC and differential results has replaced the traditional manual or individual assay methods for hematologic parameters and the eyecount leukocyte differential as the initial screening and detection system for hematologic abnormalities in modern hospitals and clinics. The traditional review of all automated hematology instrument results by preparation, staining, and microscopic examination of a blood film has disappeared in most institutions. The reasons are the more accurate detection of specimens with distributional or morphologic abnormalities by the instruments than by the traditional eyecount method. The opportunity for a clinician to request a microscopic examination of a blood film, whether or not it is flagged, must be preserved, because the clinician's knowledge of the patient's history, physical findings, and current or prior therapy may indicate review to discover an abnormality that may not have been apparent from the instrument results alone. There has also been a dramatic reduction of the numbers of medical technologists and technicians in medical laboratories. Automation of the CBC and differential counts has reduced the number of technologists needed for performance of these tests. But other factors have had a negative effect, such as the necessity to reduce costs. Consolidation of hematology and chemistry laboratories in core laboratories may produce savings in labor costs, but may also create problems of creating and maintaining areas of expertise, such as hematologic morphology, because of the cross-training required and the necessity of personnel to do all things. This article suggests and documents a number of measures that can be infinity stituted by the laboratory and by clinicians to reduce the number of eyecount differentials and blood film reviews that need to be performed. The first effort is to convince clinicians that valid data exist that confirm that a policy of allowing the laboratory to initiate blood film review based on findings of the CBC and automated differential is a more sensitive and accurate method of detecting patients with blood film abnormalities than routine blood film review of all specimens by technologists. Clinicians need to recognize that daily differential results or differentials at intervals of less than a week are not medically necessary in most patients. The laboratory, however, must provide opportunities for the clinician to request differentials at any time for specific medical reasons. The laboratory must establish the validity of screening criteria for detection of distribution and morphologic abnormalities of leukocytes by clinical correlation studies or adopt criteria established by laboratories with the same instrumentation and which have conducted clinical evaluations. A final observation on the eyecount differential is that it was the only way to identify cell types and their relative proportion for nearly 100 years. Cells were identified by their shape, intracellular structures, and staining characteristics. Many studies were able eventually to correlate some aspect of each cell type's function with their morphologic appearance. It has also been learned that the bone marrow is the source of production of most circulating cells and a great deal of the controls of cell production and release into the peripheral blood have been learned. But leukocytes have many functions, almost none of which are performed in the peripheral blood. The peripheral blood is mainly a conduit from the bone marrow to the tissues where the leukocytes perform their function in the case of the neutrophils and monocytes. It is mainly a recirculation and redistribution system for lymphocytes that usually receive their instructions from antigen processing cells in the tissues and allow these modified cells to home to sites where their functions occur. Cellular morphology and staining characteristics tell little about the maturation stage and functional capabilities of leukocytes. One cannot tell the difference between a band and a segmented neutrophil or whether a lymphocyte is a T or B cell on the conventional eyecount differential. One cannot tell the mature granulocyte of a patient with chronic myeloid leukemia from a normal mature neutrophil. Increasingly, techniques are being developed to identify better the maturation stages of cells and association with specific functional capabilities by flow cytometric techniques. The neoplastic nature of some normal-appearing leukocytes can be identified by techniques, such as fluorescent in situ hybridization. With the rapid advances in many approachs to understand the nature and functional capability of leukocytes, the eyecount differential with the traditional Romanowsky stain may be past the apogee of its ascent and beginning its trip into history along with the hemocytometer counting chamber and the Sahli pipet. The development and implementation of new laboratory cornerstone techniques for diagnosis of hematologic disease are eagerly awaited. On the other hand, the red cells and platelets exist to function in the peripheral blood. More emphasis is needed in the development of automated methods of determining the nature and functional capabilities of these true blood cells as part of the CBC.

Hematology↗

Robotics in the medical laboratory.

Robotic systems specifically designed for the automation of laboratory tasks are now available commercially. Equipped with computer, analytical hardware, and supporting software, these devices may soon revolutionize the concept of the clinical laboratory and usher in a new era in laboratory testing. We review the types of robots and motion-control software currently available and discuss examples of their applications that extend across many analytical areas. Several ongoing projects are concerned with the systematic integration of robotic devices with other laboratory automation. The integrated robotic laboratories emerging from this work portend a bright future for robotic automation. Many challenges remain, however, in training the individuals needed to develop and manage robotic laboratories, and in making this new technology cost-efficient.

Laboratories, Hospital↗

Technological change and clinical laboratory utilization.

Many believe that improvement in laboratory automation has been responsible for the considerable growth in the volume of tests that has occurred in recent years. Results are presented from an 8-year national survey of hospital laboratory utilization that show no definitive correlation between technological change and growth in volume of well-established clinical laboratory tests. These results leave room for hypothesizing other major contributory factors to volume increases such as a behavioral change on the part of practitioners who order tests and place increased diagnostic importance on laboratory results in addition to medical histories and physical examinations. If the findings prove correct, successful regulatory strategies for the containment of laboratory costs might be as likely to come from those that directly address practitioners' behavior as from those that limit capacity by requiring prior approval for acquisition of new laboratory equipment.

Autoanalysis↗

Predictions for rapid methods and automation in food microbiology.

A discussion is presented on the present status of rapid methods and automation in microbiology. Predictions are also presented for development in the following areas: viable cell counts; real-time monitoring of hygiene; polymerase chain reaction, ribotyping, and genetic tests in food laboratories; automated enzyme-linked immunosorbent assay and immunotests; rapid dipstick technology; biosensors for Hazard Analysis Critical Control Point programs; instant detection of target pathogens by computer-generated matrix; effective separation and concentration for rapid identification of target cells; microbiological alert systems in food packages; and rapid alert kits for detecting pathogens at home.

Automation↗

High-throughput purification of single compounds and libraries.

The need for increasing productivity in medicinal chemistry and associated improvements in automated synthesis technologies for compound library production during the past few years have resulted in a major challenge for compound purification technology and its organization. To meet this challenge, we have recently set up three full-service chromatography units with the aid of in-house engineers, different HPLC suppliers, and several companies specializing in custom laboratory automation technologies. Our goal was to combine high-throughput purification with the high attention to detail which would be afforded by a dedicated purification service. The resulting final purification laboratory can purify up to 1000 compounds/week in amounts ranging from 5 to 300 mg, whereas the two service intermediate purification units take 100 samples per week from 0.3 to 100 g. The technologies consist of normal-phase and reversed-phase chromatography, robotic fraction pooling and reformatting, a bottling system, an automated external solvent supply and removal system, and a customized, high-capacity freeze-dryer. All work processes are linked by an electronic sample registration and tracking system.

Automation↗

[Clinical laboratory system in a complete electronic hospital].

The use of a Laboratory Information System (LIS) and Laboratory Automation System (LAS) are clearly superior to manual results in terms of completeness and legibility. As the current clinical information system (CIS) in Gifu University Hospital consists of a complete electronic medical record system, the clinical laboratory was re-engineered to simplify workflow, pay attention to quality assurance, and decrease various costs by an intelligent laboratory management system. We named the new system Gifu Premiotic Intelligent Laboratory System (GPILS). Further advances will concentrate on the cost-effective use of LIS, and the potential use of GPILS in our laboratories will be discussed. In addition, because one of our clinical laboratories currently provides various useful clinical laboratory-oriented information to physicians and patients, we have developed new tools named the "Reference Data Base (RefDB)". In the near future, several different types of computer technology for various clinical laboratory information will lead to the development of highly specific platforms for LIS corresponding to a complete electronic medical record system.

Clinical Laboratory Information Systems↗

Automated enzymatic standardized lipid analyses for plasma and lipoprotein fractions.

Excellent normal ranges for plasma lipid and lipoprotein cholesterol levels have been developed by the Lipid Research Clinics program, standardized by the Centers for Disease Control (CDC). However these values were generated by methods not currently in use in most clinical chemistry laboratories. Automated enzymatic methods for cholesterol, triglycerides and free glycerol determinations, as well as a dextran sulfate-Mg2+ procedure for separation of high density lipoproteins (HDL) with standardization are described. Similar methods for the measurement of unesterified cholesterol and phospholipids are also given. Serum pools for total cholesterol with values ranging from 1220-3490 mg/l produced coefficients of variation (CV) less than or equal to 2.85%; reference values for low total cholesterol samples in a range of 280-727 mg/l gave CV of 4.35% or less; HDL cholesterol reference values of 265-640 mg/l yielded CV less than or equal to 3.70%; and values for triglycerides between 0.74 and 3.05 mmol/l gave CV of 4.22% or less through three to eight testing cycles (9-24 mth). These data indicate that long term CDC standardization of total cholesterol, triglycerides, and HDL cholesterol can be obtained with automated enzymatic methods utilizing commercially available reagents.

Blood Chemical Analysis↗

Nucleotide sequence-based typing of bacteria and the impact of automation.

DNA-based typing methods are increasingly important for the characterisation of bacteria. They are used to monitor the epidemiology of pathogens with public health significance and also to help understand the evolution and population biology of bacteria. However, these methods require accuracy and reproducibility and are often of a high-throughput nature. Laboratory automation is therefore the key to the successful implementation of such methods. This review describes the impact of automation on DNA-based typing methods, particularly multi-locus sequence typing (MLST), and the method components that can be automated.

Automation↗