Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “ASD”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15Linked to original sources

Transcatheter atrial septal defect closure: modified balloon sizing technique to avoid overstretching the defect and oversizing the Amplatzer septal occluder.

The objective of this study was to evaluate a new technique of sizing atrial septal defects (ASDs) for transcatheter device closure. ASD closure using the Amplatzer septal occluder (ASO) device is commonly performed. Complications, including arrhythmias, pericardial effusions, and perforations, may be related to oversizing ASDs and choosing larger devices. Two methods were used to size ASDs using a compliant balloon. In some patients, the balloon was inflated until a waist was visible [(+)waist]; in others, only until no shunting was demonstrable by echocardiogram [echo; (-)waist]. The device was selected and implanted using standard procedure and echo guidance. One hundred seventeen patients underwent secundum ASD closure with an ASO device. There were 43 patients in the (-)waist group and 74 in the (+)waist group. All devices were implanted successfully. The initial echo ASD diameter was larger in the (-)waist group compared to the (+)waist group (P = 0.01). There was a smaller difference between the initial echo and balloon-sized ASD diameters in the (-)waist group (P < 0.02). ASO device size implanted (in mm greater than echo ASD diameter) was smaller in the (-)waist group (P < 0.01). There were 0/43 complications in the (-)waist group and 5/74 in the (+)waist group. The complete closure rate was the same in both groups. Sizing an ASD by inflating a compliant balloon just until shunting is eliminated, and not until a waist is visible, results in less overstretching of the ASD and selection of a smaller ASO device, achieving similar closure rates and potentially fewer complications.

Adolescent↗

Predictors of successful transcatheter closure of atrial septal defect by cardiac magnetic resonance imaging.

The location, size, and rim of an atrial septal defect (ASD) are major determining factors for transcatheter closure. We compared the measurements of ASD size and the characteristics of atrial septal rim using cardiac magnetic resonance imaging (MRI) with those obtained using transesophageal echocardiography (TEE). Patients with an ASD that met established criteria were selected for evaluation by cardiac MRI and TEE. There were 66 patients who underwent both TEE and cardiac MRI. Bland-Altman comparative analysis was performed to demonstrate agreement between measurement of ASD by MRI and balloon sizing compared to measurement of ASD by TEE and balloon sizing. Twelve patients were excluded from transcatheter closure of ASD. TEE did not demonstrate an adequate measurement of the posterior inferior rim in 10 of 66 patients. Fifty-four patients underwent transcatheter closure using the Amplatzer septal occluder. Of these, 52 patients had successful closure (ASD measurements of 25.9 +/- 5.6 mm using MRI and 21.9 +/- 5.8 mm using TEE). The median device size was 28 mm (range, 11-38). Patients who had successful closure had a significantly smaller major axis of ASD and larger posterior inferior rim compared to those of patients who were excluded from the closure procedure. Cardiac MRI showed a better correlation of ASD diameter measurement to balloon sizing compared to TEE. We believe that the most important predictive factor for successful transcatheter closure of an ASD is an adequate posterior inferior rim, which is best visualized using cardiac MRI.

Adolescent↗

Spontaneous closure of atrial septal defects.

Atrial septal defects (ASDs) are found more frequently in the pediatric population than in adults, and improved diagnostic techniques with echocardiography (2DE) and Doppler facilitate diagnosis so that repair is possible at an optimal time. The purpose of our investigation was to study the size of ASDs at diagnosis, how size changes during follow-up, and to explore the relationship between size at diagnosis and need for surgery. We reviewed the medical records of all patients in Iceland with the diagnosis of ASD born between 1984 and 1993. ASD was confirmed by 2DE in all patients and defects smaller than 4 mm were excluded. ASD size was measured by 2DE from subxyphoid long and short axis views. There were 91 patients-29 males and 62 females. Four patients died from causes other than the heart defect and had not been operated upon. Seven patients with ASD primum and sinus venosus defects were excluded from analysis. There were 29 patients with a 4 mm defect, 17 patients with 5 or 6 mm defects, 8 patients with 7 or 8 mm defects, and 26 patients had defects >8 mm. In the 4 mm group, in 26 patients (89%) the ASD closed spontaneously or decreased in size, and 1 patient had been operated upon. In the 5 or 6 mm group, 15 of 19 ASDs (79%) had closed spontaneously, and 2 patients (9.5%) had been operated upon. In the 7 or 8 mm group, 1 of 6 ASDs (16.6%) had closed spontaneously and 3 had been closed surgically. In the >8 mm group, 1 of 24 ASDs had closed spontaneously and 20 (91%) had been closed surgically. We conclude that defects smaller than 6 mm in diameter are very likely to close spontaneously although follow-up is necessary. Defects larger than 8 mm have a high probability requiring operative closure.

Blood Flow Velocity↗

Molecular cloning of the aspartate 4-decarboxylase gene from Pseudomonas sp. ATCC 19121 and characterization of the bifunctional recombinant enzyme.

L-Aspartate 4-decarboxylase (Asd) is a major enzyme used in the industrial production of L-alanine. Its gene was cloned from Pseudomonas sp. ATCC 19121 and characterized in the present study. The 1,593-bp asd encodes a protein with a molecular mass of 59,243 Da. The Asd from this Pseudomonas strain was considerably homologous to other Asds and aminotransferases, and has evolved independently of these enzymes from gram-positive microbes. Productivity rate of the C-terminal His-tagged fusion Asd was at 33 mg/l of Escherichia coli transformant culture. The kinetic parameters K (m) and V (max) of the fusion protein were 11.50 mM and 0.11 mM/min, respectively. Gel filtration analysis demonstrated that Asd is a dodecamer at pH 5.0 while 4.4 % of the recombinant protein dissociated into dimer when the pH was increased to 7.0. Asd exhibited its maximum activity at pH 5.0 and specific activity of 280 U/mg, and remained stable over a broad range of pH. The optimum temperature for Asd reaction was 45 degrees C, and 92 % of the activity remained when the enzyme was incubated at 40 degrees C for 40 min. This enzyme did not have any preferred divalent cation for catalysis. The recombinant Asd also exhibited aminotransferase activity when D,L-Asp, L-Glu, L-Gln, and L-Ala were utilized as substrates. However, the decarboxylation activity of L-aspartate was 2,477 times higher than its aminotransferase activity. The present study is the first investigation on the important biochemical properties of the purified recombinant Asd.

Amino Acid Sequence↗

Echocardiographic estimation of balloon-stretched diameter of secundum atrial septal defect for transcatheter occlusion.

Stretched diameter of the atrial septal defect (ASD), determined by balloon sizing at cardiac catheterization, is commonly used to select the sizes of the devices used for transcatheter closure of the secundum ASD. We have previously evaluated the utility of pulmonary/systemic flow ratio and angiographic and echocardiographic (echo) sizes of the ASD in estimating stretched ASD diameter in a group of 16 patients and determined that echo diameter had the best correlation with stretched diameter (r = 0.82; p less than 0.001). The stretched diameter can be estimated: 1.05 x echo diameter in millimeters + 5.49. In this study we have prospectively evaluated this formula in estimating the stretched ASD diameter by two-dimensional echo measurements obtained in two (long and short-axis) subcostal views in another group of 21 patients aged 2.5 to 29 years (median 4.5 years). The echo size of the ASD was 9.7 +/- 3.0 mm, whereas the measured stretched diameter was 15.3 +/- 4.0 mm. The predicted stretched ASD diameter was calculated according to the above formula and was 15.7 +/- 3.1 mm, not significantly different (p greater than 0.1) from the measured stretched diameter. The correlation between predicted and measured stretched ASD sizes was excellent (r = 0.9; p less than 0.001). The mean squared error was 2.4. The differences between measured and predicted values were within 2 mm in all but three patients. It is concluded that stretched ASD diameter can be estimated accurately by two-dimensional subcostal echo measurements, which in turn could be used for selection of device size for occlusion of the ASD.

Catheterization↗

Comparison of strain rate imaging for quantitative evaluation of regional left and right ventricular function after surgical versus percutaneous closure of atrial septal defect.

For the first time, peak systolic strain and strain rate (SR) were used to assess right ventricular (RV) and left ventricular (LV) regional function in children after transcatheter and surgical atrial septal defect (ASD) closure. Fifteen patients with successful ASD device closure (the ASD-D group, mean age 9 +/- 3 years), 15 age- and gender-matched patients with successful ASD surgical closure (the ASD-S group, mean age 9 +/- 3 years), and 15 age- and gender-matched controls were enrolled. Regional RV and LV longitudinal function was significantly reduced in the ASD-S group compared with controls in all the studied segments. The ASD-D group presented significantly (p <0.001) reduced strain and SR values only on the basal and mid segments of the septal wall compared with controls. In the ASD-D group, only the RV basal segment showed significantly (p <0.001) reduced strain and SR values compared with controls but significantly greater values than those measured in the ASD-S group. SR imaging indexes could provide new, noninvasive, clinically relevant insight into regional changes in RV function and support the transcatheter approach to ASD for its less negative impact on RV and LV function.

Balloon Occlusion↗

Family study of fibromyalgia and affective spectrum disorder.

BACKGROUND: Fibromyalgia is one member of a proposed group of psychiatric and medical disorders, collectively termed affective spectrum disorder (ASD), hypothesized to share possibly heritable pathophysiologic features. Two predictions of the ASD hypothesis were tested: ASD, taken as a single entity, aggregates in families; and fibromyalgia coaggregates with other forms of ASD in families. METHODS: Probands with and without fibromyalgia, together with their first-degree relatives, were administered structured diagnostic interviews. Noninterviewed relatives were diagnosed according to information provided by interviewed relatives. Aggregation and coaggregation of disorders were analyzed with proband predictive logistic and linear regression models. RESULTS: In 533 relatives of 78 probands with fibromyalgia and 272 relatives of 40 probands without fibromyalgia, the estimated odds ratio (OR) (95% confidence interval) for the familial aggregation of ASD was 1.8 (.97, 3.2), p = .065, and the increase in number of forms of ASD in a relative for each additional form of ASD in a proband was .076 (.027, .1240), p = .002. The OR for the coaggregation of fibromyalgia with other forms of ASD was 2.0 (1.2, 3.2), p = .004; this remained significant even after excluding all mood-disorder diagnoses: 1.8 (1.1, 3.0), p = .012. CONCLUSIONS: These findings support familial aggregation of ASD collectively and familial coaggregation of fibromyalgia with other forms of ASD.

Adolescent↗

Surgical validation and implications for transcatheter closure of quantitative echocardiographic evaluation of atrial septal defect.

Accurate evaluation of secundum atrial septal defect (ASD) is important for the success of transcatheter closure. The purpose of this study was (1) to describe a quantitative evaluation by transthoracic (TTE) and transesophageal (TEE) echocardiography of the various morphologic features of ASD that might be important for patient selection for transcatheter closure, and (2) to assess the reliability of these 2 methods by surgical findings. Preoperative TTE and TEE were used to evaluate the ASD of 27 children undergoing surgical closure. Measurements included the diameters of ASD and the atrial septal lengths in the transverse and longitudinal axis, and the width of the superior, inferior, anteroinferior, and posterior septal margins. The shape and location of the ASD and the adequacy of the septal margins for anchoring occluding devices were determined. Echocardiographic data were compared with corresponding surgical measurements. No significant difference occurred in the means of all the parameters measured with the 3 methods, except for the transverse ASD diameter (p <0.05). Good agreement occurred between TTE and TEE and surgical data, except for the transverse ASD diameter, transverse atrial septal length, and the posterior septal margin on TTE. Intraclass correlations between TTE and TEE and surgical measurements of all parameters were good, except for the transverse ASD diameter. The accuracy in determining shape and location of the ASD by TTE and TEE were 100%, whereas that for determining the adequacy of septal margins was 98% and 97%, respectively. In conclusion, TTE and TEE are reliable methods for quantitative evaluation of ASD.

Cardiac Catheterization↗

Obsessive-compulsive symptoms in parents of Tourette syndrome probands and autism spectrum disorder probands.

Obsessive-compulsive symptoms (OCS) frequently occur in patients with Tourette syndrome (TS) and autism spectrum disorders (ASD). It has been suggested that genetic factors play a role in the transmission of both TS and ASD and that obsessive-compulsive disorder (OCD) may have some genetic relationship with these disorders. The objective of this study was to explore whether the OCS associated with TS and ASD were found in the parents of TS and ASD probands by comparing them with normal controls. The subjects were parents of 13 TS and 16 ASD probands. All parents underwent an examination for tic symptoms and OCD, and completed the Maudsley Obsessional Compulsive Inventory (MOCI) and State-Trait Anxiety Inventory (STAI). No significant differences were observed in the MOCI and STAI scores among all three groups. However, the MOCI total score was higher in fathers of ASD probands than in male normal controls with a marginal significance. There was a significant tendency for the mean cleaning score of MOCI in fathers of ASD probands to be higher than that in male normal controls, and the mean checking score in fathers of ASD probands was fourfold higher than that in male normal controls, although there was no significant difference. No significant relationship was observed between OCS in TS or ASD probands and OCS of their parents. Further studies on OCD and OCS including a dimensional approach within ASD families are needed.

Adult↗

Discrepancy of performance among working memory-related tasks in autism spectrum disorders was caused by task characteristics, apart from working memory, which could interfere with task execution.

Working memory performance has been inconsistently reported in autism spectrum disorders (ASD). Several studies in ASD have found normal performance in digit span and poor performance in digit symbol task although these are closely related with working memory. It is assumed that poor performance in digit symbol could be explained by confirmatory behavior, which is induced due to the vague memory representation of number-symbol association. Therefore it was hypothesized that the performance of working memory task, in which vagueness did not cause confirmatory behavior, would be normal in ASD. For this purpose, the Advanced Trail Making Test (ATMT) was used. The performance of digit span, digit symbol and ATMT was compared between ASD and normal control. The digit span, digit symbol and ATMT was given to 16 ASD subjects and 28 IQ-, age- and sex-matched control subjects. The scores of these tasks were compared. A significantly lower score for ASD was found only in digit symbol compared with control subjects. There were no significant difference in digit span and working memory estimated by ATMT. Discrepancy of scores among working memory-related tasks was demonstrated in ASD. Poor digit symbol performance, normal digit span and normal working memory in ATMT implied that ASD subjects would be intact in working memory itself, and that superficial working memory dysfunction might be observed due to confirmatory behavior in digit symbol. Therefore, to evaluate working memory in ASD, tasks that could stimulate psychopathology specific to ASD should be avoided.

Adult↗

Transcatheter closure of secundum atrial septal defect with a new self-expanding nitinol double disk device (Amplatzer device): experience in Nanjing.

PURPOSE: Various devices have been developed for the transcatheter closure of secundum atrial septal defect (ASD II) to avoid the morbidity, discomfort, and thoracotomy scar associated with surgical closure. The purpose of this study was to evaluate the safety and efficacy of the Amplatzer septal occluder for transcatheter closure of ASD II. PATIENTS AND METHODS: Only patients who were clinically diagnosed with ASD II were selected. The anatomy of ASD had to meet certain echocardiographic criteria. Under the guidance of echocardiography and fluoroscopy, the implantation of the device was accomplished as recommended by the manufacturer. RESULTS: Thirty patients (median age 18.4 years) with an ASD II underwent transcatheter closure. Procedure time ranged from 30-200 minutes and fluoroscopy time from 10-50 minutes. The diameter of the ASD measured by echocardiography ranged from 13-25 mm, while both the stretched diameters of the ASDs and the sizes of the devices ranged from 18-34 mm. The successful placement rate was 100%. The residual shunt rate was 100% immediately after device implantation and 10% after 24 hours. After 3 months, 3.3% of the patients had a (trivial) residual shunt. The device did not affect the surrounding structures of ASD. No embolization of the device occurred. CONCLUSION: The Amplatzer device designed for the closure of ASD II can be implanted easily and also is retrievable. Due to a low ratio of residual shunt and few complications, this device is a good choice for transcatheter closure of ASD II. Long-term follow-up will be required for widespread clinical use.

Adolescent↗

Natural history of growth of secundum atrial septal defects and implications for transcatheter closure.

OBJECTIVE: To investigate the natural history of secundum atrial septal defects (ASDs) over several years using serial echocardiographic studies. METHODS: All patients with isolated secundum ASDs who had serial transthoracic echocardiograms at Texas Children's Hospital, Houston, Texas, from January 1991 to December 1998 were identified. Patients with fenestrated or multiple ASDs, other congenital heart defects, or less than a six month interval between echocardiograms were excluded. There were 104 patients eligible for inclusion in the study. Studies were reviewed by two echocardiographers (blinded) and the maximal diameter was recorded. Defects were defined as small (> 3 mm to < 6 mm), moderate (> or = 6 mm to < 12 mm), or large (> or = 12 mm). ASDs that grew > or = 20 mm were defined as having outgrown transcatheter closure with the device available to the authors' institution. RESULTS: ASD diameter increased in 68 of 104 patients (65%), including 31 patients (30%) with a > 50% increase in diameter. Spontaneous closure occurred in four patients (4%). Thirteen defects (12%) increased to > or = 20 mm. One fifth of the patients studied had an insufficient atrial rim by transthoracic echocardiogram to hold an atrial septal occluder. The only factor associated with significant growth of ASDs was initial size of the defect. ASD growth was independent both of age at diagnosis and when indexed to body surface area. CONCLUSIONS: Two thirds of secundum ASDs may enlarge with time and there is the potential for secundum ASDs to outgrow transcatheter closure with specific devices. Further development in devices and general availability of devices capable of closing larger ASDs should circumvent this problem.

Adolescent↗

Counseling parents regarding prognosis in autistic spectrum disorder.

A triaxial model for autistic spectrum disorder (ASD) is presented, incorporating age, degree of intelligence, and severity of autistic features. As the name implies, ASD can vary in degree of expression from minimal to profound. Furthermore, the symptoms of ASD change in predictable ways with the passage of time. For example, echolalia during early childhood may be replaced by verbal literalism and difficulty with verbal humor during later childhood or adolescence. The prognosis for children with ASD is governed by the joint impact of the degree of expression of ASD and the degree of developmental delay, if any. All combinations of ASD and intellect are possible (ie, severe ASD plus severe mental retardation, severe ASD plus normal general intelligence, and so forth). The relationship among these 3 parameters-severity of ASD, level of general intelligence, and change in symptom expression over time, is represented schematically as a 3-dimensional graph. The utility of this graph as a counseling tool, and as the basis for future research on the prognosis of ASD are discussed.

Age Factors↗

Transesophageal echocardiography to evaluate success of transcatheter closure of large secundum atrial septal defects in adults using the buttoned device.

OBJECTIVES: To determine the success rate of transcatheter closure of secundum atrial septal defects (ASDs) in adults and to characterize anatomical structures predisposing to unsatisfactory results. PATIENTS AND METHODS: Preinterventional and follow-up transesophageal echocardiography of 17 consecutive patients treated with a Sideris buttoned device was reviewed. Residual jet size of 5 mm or smaller was considered an adequate result; jet size larger than 5 mm was inadequate. Maximal ASD diameter, ASD area, and anterior, posterior, superior, and inferior septal rims were measured. RESULTS: The 7 patients with adequate results (41%) had smaller defects before implantation of a buttoned device (mean +/- SD maximal ASD diameter, 12 +/- 4 vs 19 +/- 5 mm; P<.005). Total rim length (mean +/- SD) was longer in patients with an adequate result (71 +/- 8 vs 46 +/- 11 mm; P<.001). The ASD size and length of the superior septal rim were independent predictors for an adequate result. Only 3 patients, all with ASD diameter less than 13 mm, had completely closed defects. All patients with ASD diameter greater than 20 mm had inadequate results and an unsatisfactory device position. The defect size (mean +/- SD) was similarly reduced in patients with adequate and inadequate results (9 +/- 3 vs 8 +/- 4 mm). CONCLUSION: Adults with a small ASD are more likely to have an adequate result after treatment with the buttoned device. A sufficiently large superior septal rim is particularly important for an adequate result. Most patients with a large ASD have inadequate results, although their ASD size is reduced by a similar absolute area as in patients with an adequate result.

Adolescent↗

Acute Stress Disorder Scale: a self-report measure of acute stress disorder.

The Acute Stress Disorder Scale (ASDS) is a self-report inventory that (a) indexes acute stress disorder (ASD) and (b) predicts posttraumatic stress disorder (PTSD). The ASDS is a 19-item inventory that is based on Diagnostic and Statistical Manual of Mental Disorders (4th ed.; DSM-IV, American Psychiatric Association, 1994) criteria. The ASDS possessed good sensitivity (95%) and specificity (83%) for identifying ASD against the ASD Interview on 99 civilian trauma survivors. Test-retest reliability of the ASDS scores between 2 and 7 days was strong (r = .94). The ASDS predicted 91% of bushfire survivors who developed PTSD and 93% of those who did not; one third of those identified by the ASDS as being at risk did not develop PTSD, however. The ASDS shows promise as a screening instrument to identify acutely traumatized individuals who warrant more thorough assessment for risk of PTSD.

Acute Disease↗

Transesophageal echocardiographic monitoring for transcatheter closure of atrial septal defect.

BACKGROUND AND PURPOSE: Transcatheter closure of atrial septal defect (ASD) is generally performed under fluoroscopy alone. Recently, we have used transesophageal echocardiography (TEE) monitoring as an aid in performing this procedure. The purpose of this study was to evaluate the efficacy and complications associated with this use of TEE. METHODS: Transcatheter closure of ASD was accomplished under TEE guidance simultaneously with fluoroscopic imaging in 11 patients aged 3 to 33 years (weight, 15.4-62.9 kg). TEE was successfully performed in all patients after endotracheal general anesthesia. The ASDs were reexamined before catheterization. The appropriate placement of the occluder device was evaluated. RESULTS: Seven cases were uneventful with successful ASD occluder implantation, but one failed because of a large ASD (24.7 mm). In three cases, transcatheter closure was aborted after TEE examination, one with a large ASD (27.05 mm), one with an ASD that was too small, and one with multiple fenestrated ASDs. CONCLUSIONS: Routine TEE monitoring for transcatheter closure of ASDs is effective for evaluation of ASD before implantation of an occluder, to ensure the proper seating of the occluder after the defect occlusion is complete.

Adolescent↗

Intermediate term follow-up on transcatheter closure of atrial septal defects by Amplatzer septal occluder.

BACKGROUND: Surgical repair of secundum atrial septal defect (ASD) is a safe, widely accepted procedure with negligible mortality. However, it is associated with morbidity, discomfort and a thoracotomy scar. As an alternative to surgery, a variety of devices for transcatheter closure of ASD have been developed. OBJECTIVES: We report our clinical experience with transcatheter closure of ASD using the Amplatzer Septal Occluder, a new occlusion device with intermediate term follow-up. PATIENTS & METHOD: Patients having ASD met established two-dimensional echocardiographic criteria for transcatheter closure were selected. ASD size was measured by transesophageal echocardiogram (TEE) and balloon occlusion catheter (stretched diameter). The Amplatzer's size was chosen to be equal to or 1 mm less than the stretched diameter. The device was advanced transvenously into a guiding sheath and deployed under fluoroscopic and TEE guidance. Once its position was optimal, it was released. TEE was undertaken to demonstrate the residual shunt. RESULTS: There were 26 patients with a mean age of 17.2 +/- 15.9 years old (2 to 60) and a mean weight of 22 +/- 37.5 kg. (10.7 to 62.5). The mean ASD diameter measured by TEE was 18.3 +/- 5.2 mm. and by stretched diameter was 22 +/- 7.5 mm. Four patients who had ASD stretched diameter over 32 mm were excluded because a larger device was not available. Devices were deployed in 22 patients with sizes from 9 to 30 mm (median = 22mm). Immediately after closure a tiny residual shunt was observed at the core of the device in each case. At 24 hours only two patients had a small (< 2 mm) shunt. One patient with fenestrated ASD had a device embolized into the right ventricle with successful removal and surgical closure. Patients were followed-up for a mean duration of 8 +/- 3.5 months (from 3 to 12 months). Complete occlusion was found in 20 out of 21 patients (95%). CONCLUSION: The Amplatzer Septal Occluder is a new device designed for closure of different sizes of ASD and can be easily and safely deployed. Our experience showed that this device could be used to close an ASD as large as 30 mm. The intermediate term follow-up also demonstrated an excellent closure result. Caution should be undertaken with patients who have a fenestrated atrial septal defect particularly at the septal rim.

Adolescent↗

Echocardiographic parameters of left ventricular systolic and diastolic function in infants, children and adolescents before and after surgical correction of secundum atrial septal defect.

BACKGROUND: Left ventricular (LV) dysfunction has been described in adults with secundum atrial septal defect (ASD II) and heart failure (CHF). This anomaly has been rarely regarded as a cause of CHF in pediatric patients with ASD II. AIM: To assess LV systolic and diastolic function in patients with ASD II before and after cardiosurgery as well as to establish the prognostic value of these parameters in infants, children and adolescents with ASD II. METHODS: LV systolic (LVEF) and diastolic function parameters (E/A, DCT, IVRT) were studied using Doppler echocardiography in 104 patients aged between 1-18 years with ASD II before cardiosurgery and 4 years afterwards. These parameters were compared with similar variables in 150 healthy infants, children and adolescents. RESULTS: Before surgery LVEF was significantly lower only in infants with ASD II and CHF when compared with healthy controls. Relaxation abnormalities of LV diastolic function were observed before surgery in 40.4% of patients, especially in infants and adolescents with CHF. These disturbances were still present in about 20% of patients after surgery, especially in infants. Before and after surgery both LV and RV end-diastolic volumes were normal in about 6-10% of patients with LV diastolic dysfunction. CONCLUSIONS: In patients with ASD II and CHF diastolic dysfunction of LV is more common than systolic dysfunction. RV volume overload mainly affects LV diastolic function but it is not the only cause of CHF in patients with ASD II, especially in infants and adolescents. After surgery, normalisation of LV diastolic function is not observed in about 20% of patients with ASD II, especially in those who had CHF before operation. Special monitoring of the circulatory system is necessary in patients with ASD II operated in infancy and adolescence.

Journal Article↗