Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “surface modification”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14Linked to original sources

Real-time evidence of surface modification at polystyrene lattices by poloxamine 908 in the presence of serum: in vivo conversion of macrophage-prone nanoparticles to stealth entities by poloxamine 908.

Intravenously injected polystyrene nanoparticles, which are prone to rapid sequestration by professional phagocytes, are converted to stealth entities by prior bolus intravenous injection of poloxamine 908. This behaviour is not due to alteration in macrophage phagocytic activity. Laser Doppler anemometry and surface plasmon resonance were used to unravel the mechanisms fundamental to generation of such stealth entities in vivo by poloxamine 908. Electrophoretic mobility of poloxamine pre-coated monodisperse polystyrene nanoparticles in serum, which behave as stealth entities in vivo, was similar to that of uncoated nanoparticles incubated in poloxamine pre-treated serum. This observation supported the notion that poloxamine in serum can modify the surface of nanoparticles with similar topography to that of stealth poloxamine pre-coated particles, i.e. with polyoxyethylene chains projected from the surface. Surface plasmon resonance optical phenomenon was used for real-time monitoring of protein-poloxamine interactions and adsorption at the polystyrene interface. It was found that poloxamine can not only adsorb to a serum-modified surface but in addition poloxamine in serum can form macromolecular complexes with high affinity for adsorption to a polystyrene lattice. A role for serum albumin in surface modification of nanoparticles by poloxamine 908 is also identified. Hence, our biophysical observations correlate precisely with the in vivo longevity of uncoated polystyrene nanoparticles in poloxamine pre-treated rats. This rational and sensitive biophysical approach has unravelled the probable mechanism fundamental to generation of stealth entities in vivo and therefore has application in the design and nano-engineering of stealth colloidal carriers for optimal biological performance.

Animals↗

Cell surface modifications with trifluoromethyl dinitrophenyl-soluble protein conjugates: immunogenic role of noncovalently bound hapten.

Bovine serum albumin (BSA) was derivatized, under mild conditions, with trifluoromethyl-dinitrophenyl (CF3-DNP), a haptenic group cross-reacting with trinitrophenyl (TNP). High-field nuclear magnetic resonance of fluorine (19F-NMR) permitted to calculate the number of covalently and noncovalently bound haptenic groups per BSA molecule. Further dialysis against paratoluene sulfonic acid permitted to obtain CF3-DNP-BSA conjugates from which noncovalently bound hapten had been removed. Soluble conjugates containing 4 covalently bound plus 1 noncovalently bound hapten groups, or only 4 covalently bound groups, were added to splenocytes in culture. These splenocytes, after such treatments, were added to effector lymphocytes in a 5-day culture aimed at the generation of cytotoxic T lymphocytes (CTL) against the CF3-DNP-induced cell surface modification antigens. It was found that only the BSA conjugates that contained noncovalently bound haptens were able to generate CTL against target cells whose surface had been directly modified with CF3-DNP, whereas BSA bearing only covalently bound hapten groups were not. Replacing BSA by human serum albumin, or CF3-DNP by TNP, gave comparable results. Thus, under the conditions used, haptenic groups covalently bound to their soluble carrier protein did not generate hapten-dependent CTL, but noncovalently bound or free haptenic groups at very low concentration were able to do so.

Antigens, Surface↗

Poly(ethylene glycol)-conjugated human serum albumin including iron porphyrins: surface modification improves the O2-transporting ability.

Artificial O2-carrying hemoprotein composed of human serum albumin including tetrakis(o-amidophenyl)porphinatoiron(II) (Fe4P or Fe3P) [HSA-FeXP] has been modified by maleimide- or succinimide-terminated poly(ethylene glycol) (PEG), and the formed PEG bioconjugates have been physicochemically characterized. 2-Iminothiolane (IMT) reacted with the amino groups of Lys to create active thiol groups, which bind to alpha-maleimide-omega-methoxy PEG [Mw: 2-kDa (PEG(M2)), 5-kDa (PEG(M5))]. On the other hand, alpha-succinimidyl-omega-methoxy PEG [Mw: 2-kDa (PEG(S2)), 5-kDa (PEG(S5))] directly binds to Lys residues. MALDI-TOF MS of the PEG-conjugated HSA-FeXP showed distinct molecular ion peaks, which provide an accurate number of the PEG chains. In the case of PEG(MY)(HSA-FeXP), the spectroscopic assay of the thiol groups also provided the mean of the binding numbers of the polymers, and the degree of the modification was controlled by the ratio of [IMT]/[HSA]. The viscosity and colloid osmotic pressures of the 2-kDa PEG conjugates (phosphate-buffered saline solution, [HSA] = 5 g dL(-1)) were almost the same as that of the nonmodified one, whereas the 5-kDa PEG binding increased the rheological parameters. The presence of flexible polymers on the HSA surface retarded the association reaction of O2 to FeXP and stabilized the oxygenated complex. Furthermore, PEG(MY)(HSA-FeXP) exhibited a long circulation lifetime of FeXP in rats (13-16 h). On the basis of these results, it can be concluded that the surface modification of HSA-FeXP by PEG has improved its comprehensive O2-transporting ability. In particular the PEG(MY)(HSA-FeXP) solution could be a promising material for entirely synthetic O2-carrying plasma expander as a red cell substitute.

Animals↗

Nano-scale surface modification of a segmented polyurethane with a phospholipid polymer.

Nano-scale modification of a segmented polyurethane (SPU) with cross-linked 2-methacryloyloxyethyl phosphorylcholine (MPC) polymer was performed to obtain a biocompatible elastomer. To control the domain size and the depth of the modified layer, various compositions of monomers, including MPC, 2-ethylhexyl methacrylate (EHMA), and glycerol 1,3-diglycerolate diacrylate, were examined. SPU film was immersed in the monomer solution and visible light irradiation was applied to initiate polymerization to the SPU film that was held by mica to condense MPC units at the surface. The surfaces of the obtained film were analyzed by X-ray photoelectron spectroscopy and water contact angle measurement. The surface density of MPC units changed with the monomer concentration, and the density was the highest when the ratio between MPC and EHMA was 7:3. In modified SPU films, 6- to 25-nm MPC unit-enriched domains were observed and the density of these domains gradually decreased with depth. The sizes of the domains depended on the MPC composition in the monomer solution. The mechanical properties of the modified films as evaluated by tensile strength measurement under wet conditions were not significantly different from those of SPU. With increase in the existence of MPC unit-enriched domains on the MEG film surface, platelet adhesion and activation were remarkably reduced compared to the SPU film. This nano-scale surface modification may be a useful technique for applying elastic polymer biomaterials.

Biocompatible Materials↗

Nanostructured surface modification of ceramic-based microelectrodes to enhance biocompatibility for a direct brain-machine interface.

Many different types of microelectrodes have been developed for use as a direct Brain-Machine Interface (BMI) to chronically recording single neuron action potentials from ensembles of neurons. Unfortunately, the recordings from these microelectrode devices are not consistent and often last for only a few weeks. For most microelectrode types, the loss of these recordings is not due to failure of the electrodes but most likely due to damage to surrounding tissue that results in the formation of nonconductive glial-scar. Since the extracellular matrix consists of nanostructured microtubules, we have postulated that neurons may prefer a more complex surface structure than the smooth surface typical of thin-film microelectrodes. We, therefore, investigated the suitability of a nano-porous silicon surface layer to increase the biocompatibility of our thin film ceramic-insulated multisite electrodes. In-vitro testing demonstrated, for the first time, decreased adhesion of astrocytes and increased extension of neurites from pheochromocytoma cells on porous silicon surfaces compared to smooth silicon sufaces. Moreover, nano-porous surfaces were more biocompatible than macroporous surfaces. Collectively, these results support our hypothesis that nano-porous silicon may be an ideal material to improve biocompatibility of chronically implanted microelectrodes. We next developed a method to apply nano-porous surfaces to ceramic insulated, thin-film, microelectrodes and tested them in vivo. Chronic testing demonstrated that the nano-porous surface modification did not alter the electrical properties of the recording sites and did not interfere with proper functioning of the microelectrodes in vivo.

Action Potentials↗

[Advances in the investigation of biological effect and surface modification of dendrimers as drug (gene) delivery systems].

Dendrimers are highly branched macromolecules that have attractive nano-sized architectures. It seems that they can enter various cells easily because of their unique nanostructures and chemical properties, which make them to be one of important candidates of non-virus carriers for drug delivery or gene therapy. However, the understanding of cytotoxicity and related mechanisms of dendrimers are still limited. In recent years there has been rapid increases of researches regarding the biological effects of dendrimers, including the interactions of dendrimers to cells, transport mechanisms, intracellular distribution and biodistribution in vivo, as well as improvement of biocompatibility of dendrimers by surface engineering. In this paper, recent advances in the investigations of biological effect and surface modification for the dendrimers as drug or gene delivery systems were reviewed.

Animals↗

Magnetic nanoparticles with surface modification enhanced gene delivery of HVJ-E vector.

To enter the realm of human gene therapy, a novel drug delivery system is required for efficient delivery of small molecules with high safety for clinical usage. We have developed a unique vector "HVJ-E (hemagglutinating virus of Japan-envelope)" that can rapidly transfer plasmid DNA, oligonucleotide, and protein into cells by cell-fusion. In this study, we associated HVJ-E with magnetic nanoparticles, which can potentially enhance its transfection efficiency in the presence of a magnetic force. Magnetic nanoparticles, such as maghemite, with an average size of 29 nm, can be regulated by a magnetic force and basically consist of oxidized Fe which is commonly used as a supplement for the treatment of anemia. A mixture of magnetite particles with protamine sulfate, which gives a cationic surface charge on the maghemite particles, significantly enhanced the transfection efficiency in an in vitro cell culture system based on HVJ-E technology, resulting in a reduction in the required titer of HVJ. Addition of magnetic nanoparticles would enhance the association of HVJ-E with the cell membrane with a magnetic force. However, maghemite particles surface-coated with heparin, but not protamine sulfate, enhanced the transfection efficiency in the analysis of direct injection into the mouse liver in an in vivo model. The size and surface chemistry of magnetic particles could be tailored accordingly to meet specific demands of physical and biological characteristics. Overall, magnetic nanoparticles with different surface modifications can enhance HVJ-E-based gene transfer by modification of the size or charge, which could potentially help to overcome fundamental limitations to gene therapy in vivo.

Animals↗

Surface modification method of microchannels for gas-liquid two-phase flow in microchips.

A capillarity restricted modification method for microchannel surfaces was developed for gas--liquid microchemical operations in microchips. In this method, a microstructure combining shallow and deep microchannels and the principle of capillarity were utilized for chemical modification of a restricted area of a microchannel. A hydrophobic--hydrophilic patterning in microchannels was prepared as an example for guiding gas and liquid flows along the respective microchannels. Validity of the patterning was confirmed by measuring aqueous flow leak pressure from the hydrophilic microchannel to the hydrophobic one. The leak pressure of 7.7-1.1 kPa agreed well with that predicted theoretically from the Young-Laplace equation for the microchannel depth of 8.6-39 microm. In an experiment to demonstrate usefulness and effectiveness of the method, an air bubble was first introduced into the hydrophilic microchannel and purged from the hydrophobic-hydrophilic patterned microchannels. Next, the patterning structure was applied to remove dissolved oxygen by contacting the aqueous flow with a nitrogen flow. The concentration of dissolved oxygen decreased with contact time, and its time course agreed well with numerical simulation. These demonstrations showed that the proposed patterning method can be used in general microfluidic gas-liquid operations.

Biomechanical Phenomena↗

Electrooxidation of ascorbic acid on a polyaniline-deposited nickel electrode: surface modification of a non-platinum metal for an electrooxidative analysis.

The electrooxidation of ascorbic acid (H2A), which does not occur on a bare Ni electrode, has been shown to take place on a polyaniline (PANI)-coated Ni electrode in aqueous electrolytes of a wide pH range. The characteristic voltammetric peak of PANI in 0.1 M H2SO4 at 0.2 V vs SCE corresponding to the transformation of leucoemeraldine to emeraldine gradually diminishes with an increase in concentration of H2A as a result of adsorption. This peak disappears before the appearance of another peak corresponding to the oxidation of H2A at a concentration of 1 mM. The irreversible oxidation current of H2A exhibits a linear dependence on the concentration. The effect of adsorption of H2A on PANI has been shown to increase the voltammetric peak current. A study on the variation of the PANI thickness and its influence on the voltammetric oxidation of H2A has led to an optimum thickness of 1.6 microm. The oxidation currents on the porous PANI/Ni electrode have been found to be several times higher at lower potentials in comparison with the data of a Pt electrode. The reaction has also been studied by ac impedance spectroscopy. In alkaline electrolytes, the Nyquist impedance plot is characterized by two semicircles instead of a single semicircle in acidic electrolytes. Thus, Ni, which is a non-platinum metal, has been found to be useful, by surface modification with PANI, for electrooxidation of H2A. The data are reproducible in the electrolytes of a wide pH range, thus suggesting a good stability, reusability and a long life for the PANI/Ni electrodes.

Adsorption↗

Preparation, characterization, and surface modification of silver nanoparticles in formamide.

The reduction of silver ions in formamide is shown to take place spontaneously at room temperature without addition of any reductant. The growth of Ag particles was found to be dependent on Ag+ ion concentration. In the absence of any stabilizer, deposition of silver film on the glass walls of the container takes place. However, in the presence of poly(N-vinyl-2-pyrrolidone) (PVP) or colloidal silica (SiO2), which are capable of stabilizing silver nanoparticles by complexing and providing support, a clear dispersion was obtained. The formation of the silver nanoparticles under different conditions was investigated through UV-visible absorption spectrophotometry, gas chromatography, and also electron and atomic force microscopic techniques. Atomic force microscopy results for silver films prepared in the absence of any stabilizer showed the formation of polygonal particles with sizes around 100 nm. Transmission electron microscopy results showed that the prepared silver particles in the presence of PVP were around 20 nm. The Ag nanoparticles get oxidized in the presence of chloroform and toluene. Surface modification of silver film was done in the presence of the tetrasodium salt of ethylenediaminetetraaceticacid (Na4EDTA). It was shown that the reactivity of the silver film increased in its presence. The Fermi potential of silver particles in the presence of Na4EDTA seems to lie between -0.33 and -0.446 V vs NHE.

Journal Article↗

Selective surface modification technique for improvement of chromatographic separation selectivity for sugar derivatives.

Highly cross-linked macroporous polymers were prepared utilizing ethylene dimethacrylate as a cross-linking agent, in the presence or absence of methyl-alpha-D-glucoside as a kind of template molecule with methacrylic acid as a functional monomer. After the preparation of the polymers, we applied a high temperature to the cross-linked polymers to study the changes of adsorption properties of the polymers for sugar derivatives including the template molecule utilized. Interestingly, the heat treatment up to 250 degrees C afforded improvement of relative adsorption affinity for several sugar derivatives including the template molecule, while heat treatment up to 150 degrees C did not afford those improvements. The detailed studies including polymers prepared using acrylic acid as a functional monomer instead of methacrylic acid prove that temperatures higher than the Tg temperature of the polymer derived from a functional monomer such as methacrylic acid and higher than the melting point (mp) of the sugar template are necessary to afford the observed improvement of relative affinity based on the surface modification effects through the heat treatment to cross-linked polymers.

Carbohydrates↗

Surface modification of poly(tetramethylene adipate-co-terephthalate) membrane via layer-by-layer assembly of chitosan and dextran sulfate polyelectrolyte multiplayer.

The improvement of hydrophilicity and hemocompatibility of poly(tetramethylene adipate-co-terephthalate) (PTAT) membrane was developed via polyelectrolyte multilayers (PEMs) immobilization. The polysaccharide PEMs included chitosan (CS, as a positive-charged and antibacterial agent) and dextran sulfate (DS, as a negative-charged and anti-adhesive agent) were successfully prepared using the aminolyzed PTAT membrane in a layer-by-layer (LBL) self-assembly manner. The obtained results showed that the contact angle of as-modified PTAT membranes reached to the steady value after four bilayers of coating, hence suggesting that the full coverage was achieved. It could be found that the PTAT-PEMs membranes with DS as the outmost layer could resist the platelet adhesion and human plasma fibrinogen (HPF) adsorption, thereby prolonging effectively the blood coagulation times. According to L929 fibroblast cell growth inhibition index, the as-prepared PTAT membranes exhibited non-cytotoxic. Overall results demonstrated that such an easy, valid and shape-independent processing should be potential for surface modification of PTAT membrane in the application of hemodialysis devices.

Adipates↗

Surface modification by complexes of vitronectin and growth factors for serum-free culture of human osteoblasts.

Cell attachment, expansion, and migration in three-dimensional biomaterials are crucial steps for effective delivery of osteogenic cells into bone defects. Complexes composed of vitronectin (VN), insulin-like growth factors (IGFs), and insulin growth factor-binding proteins (IGFBPs) have been reported to enhance cell attachment, proliferation, and migration in a variety of cell lines in vitro. The aim of this study was to examine whether prebound complexes of VN and IGFs +/- IGFBPs could facilitate human osteoblast serum-free expansion in vitro and enhance cell attachment, proliferation, and migration in three-dimensional biomaterial constructs. Human osteoblasts derived from alveolar bone chips and the established human osteoblast cell line Saos-2 were used. These cells were seeded on tissue culture plates and porous scaffolds of type I collagen sponges and polyglycolic acid (PGA), which had been coated with VN +/- IGFBP-5 +/- IGF-I. Cell attachment, proliferation, and migration were evaluated by cell counting, confocal microscopy, and scanning electron microscopy. The number of attached human osteoblasts was significantly higher in VN-coated polystyrene culture dishes. Furthermore, significant increases in cell proliferation were observed when growth factors were bound to these surfaces in the presence of VN. In the two scaffold materials examined, greater cell attachment was found in type I collagen sponges compared with PGA scaffolds. However, coating the scaffolds with complexes composed of VN + IGF-I or VN + IGFBP-5 + IGF-I enhanced cell attachment on PGA. Moreover, the presence of VN + IGFBP-5 + IGF-I resulted in significantly greater osteoblast migration into deep pore areas as compared with untreated scaffolds or scaffolds treated with fetal calf serum. These results demonstrated that complexes of VN + IGFBP-5 + IGF-I can be used to expand osteoblasts in vitro under serum-free conditions and enhance the attachment and migration of human osteoblasts in three-dimensional culture. This in turn suggests a potential application in surface modification of biomaterials for tissue reconstruction.

Bone Substitutes↗

Humidity-sensitive electrical conductivity of a Langmuir-Blodgett film of titania nanosheets: surface modification as induced by light irradiation under humid conditions.

Electrical conductivity of titania nanosheets was investigated for a single-layered Langmuir-Blodgett (LB) film deposited onto a comb-type electrode (5 or 10 microm (electrode spacing) x 8 mm (electrode width)). The photoresponsive electrical properties of the film were investigated by irradiating with a Xe lamp under various atmospheric conditions. The atmosphere was controlled by introducing either oxygen or nitrogen gases containing different amounts of water vapor. As a result, the LB film behaved as an insulator with little photoresponse under dry atmospheric conditions. It became conductive on illuminating with a Xe lamp under a wet oxygen atmosphere. Conductivity increased with the increase of irradiation time (0-30 min) to attain a stationary value in 1 h. The highest conductive state thus attained lasted for several hours in the dark. The impedance of the film was measured over the frequency range of 1 MHz to 50 Hz by varying the relative humidity of an atmosphere from 0 to 100%. The results were analyzed by assuming an equivalent circuit consisting of one resistance (R) with constant Warburg component (W) and one capacitance (C) in parallel. The R component depended remarkably on the relative humidity, while the C component stayed nearly at the constant value. The dependence of R on water vapor (PH2O) was expressed by R = A[PH2O]n with A = constant and n = -2.9. The results were rationalized in terms of the surface modification of titania nanosheets to hydrophilic nature under the illumination of UV light.

Journal Article↗

Surface modification and evaluation of some commonly used catheter materials. I. Surface properties.

Double catheter systems consisting of a stiff outer catheter and a flexible, buoyant, flow-directed, inner catheter which is often balloon-tipped have been employed with increasing frequency recently in both therapeutic and diagnostic procedures. Their use, however, has been restricted because of the excessive friction generated between the two catheters. In an attempt to decrease friction between polymers commonly used as catheter materials, oxidation of polyethylene, fluorinated ethylene-propylene copolymer, poly(vinyl chloride), silicone rubber, and polystyrene surfaces was induced by exposing the polymers to radio frequency glow discharge (RFGD) in a helium environment. All polymers were surface characterized utilizing x-ray photoelectron spectroscopy (XPS), scanning electron microscopy (SEM), and contact angle measurements before and after oxidation. This article describes the materials and methods used to fabricate and characterize the polymer surfaces and the results of the characterization. The results indicate that increases in oxygen concentration at the surface of the polymers and decreases in air-water contact angles occur with increased RFGD exposure time. Plateau values were usually obtained after 5-30 s exposure time, yet no apparent changes in surface topography were noted by scanning electron microscopy. The hydrophilic surfaces produced were stable for up to three months storage time in air.

Biocompatible Materials↗

Surface modification of haemoglobin-containing liposomes with polyethylene glycol prevents liposome aggregation in blood plasma.

With a view to prevention of liposome aggregation in plasma which is a lethal problem when using artificial erythrocytes, modification of the liposome surface with polyethylene glycol (PEG)-bound cholesterol or phospholipid was studied. The cholesterol or phospholipid moiety works as a scaffold for immobilization of the modifiers to the liposome. The modified liposome aggregability is significantly reduced with increased PEG content and particularly with increased PEG chain length. In addition, the zeta potential of modified liposomes decreases with increased PEG chain length. It is concluded that the long PEG chain exposed on the liposome surface prevents the adsorption of plasma proteins on to the surface by its excluded volume effect and, as a result, effectively reduces the liposome aggregability in plasma.

Erythrocyte Aggregation↗

Surface modification of polymers with self-assembled molecular structures: multitechnique surface characterization.

A simple, one-step procedure for generating ordered, crystalline methylene chains on polymeric surfaces via urethane linkages was developed. The reaction of dodecyl isocyanate with surface hydroxyl functional groups, catalyzed by dibutyltin dilaurate, formed a predominantly all-trans, crystalline structure on a cross-linked poly(2-hydroxyethyl methacrylate) (pHEMA) substrate. Allophanate side-branching reactions were not observed. Both X-ray photoelectron spectrocopy and time-of-flight secondary ion mass spectrometry show that the surface reaction reached saturation after 30 min at 60 degrees C. Unpolarized Fourier transform infrared-attenuated total reflection showed that, after 30 min, the stretching frequencies, vCH2,asym and vCH2,sym, decreased and approached 2920 and 2850 cm-1, indicative of a crystalline phase. The distance between two hydroxyl groups is roughly 4 A. A tilt angle of 33.5 degrees +/- 2.4 degrees was estimated by dichoric ratios measured in polarized ATR according to the two-phase and Harrick thin film approximations. The findings reported here are significant in that the possibilities for using structures similar to self-assembled monolayers (SAMs) are expanded beyond the rigid gold and silicon surfaces used through most of the literature. Thus, SAMs, biomimetics for ordered lipid cell wall structures, can be applied to real-world biomedical polymers to modify biological interactions. The terminal groups of the SAM-like structure can be further functionalized with biomolecules or antibodies to develop surface-based diagnostics, biosensors, or biomaterials.

Algorithms↗

Nd:YAG laser ablation of enamel for orthodontic use: tensile bond strength and surface modification.

To test the feasibility of Nd:YAG laser ablation for orthodontic use, bovine enamels were ablated at 2.5 and 3.5 W/pulse conditions. Orthodontic brackets were attached on the ablated enamel surface using a self-curing resin. For comparison, a 37% phosphoric acid solution was used to etch the enamel surface. The strength to detach the brackets was estimated for both surface treatments. Modifications of the enamel surfaces were also compared using a scanning electron microscope for both treatments. The tensile bond strengths from the laser-ablated enamels were significantly lower than that from the phosphoric acid-etched enamels. The higher laser power treatment gave a significantly higher bond strength average than with the lower laser power. The laser-ablated surfaces showed the formation of craters. The formation involved melting and solidification of enamel. Each crater had numerous micropores. Microscopically, the ablated surface was smooth, while much of the acid-etched surface contained numerous microspaces.

Acid Etching, Dental↗