Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “simulations”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14Linked to original sources

A new approach to mechanical simulation of lung behaviour: pressure-controlled and time-related piston movement.

A mechanical lung simulator is described (an extension of a previous mechanical simulator) which simulates normal breathing and artificial ventilation in patients. The extended integration of hardware and software offers many new possibilities and advantages over the former simulator. The properties of components which simulate elastance and airway resistance of the lung are defined in software rather than by the mechanical properties of the components alone. Therefore, a more flexible simulation of non-linear behaviour and the cross-over effects of lung properties is obtained. Furthermore, the range of lung compliance is extended to simulate patients with emphysema. The dependency of airway resistance on lung recoil pressure and transmural pressure of the airways can also be simulated. The new approach enables one to incorporate time-related mechanics such as the influence of lung viscosity or cardiac oscillation. The different relations defined in the software can be changed from breath to breath. Three simulations are presented: (1) computer-controlled expiration in the artificially ventilated lung; (2) simulation of normal breathing; and (3) simulation of viscoelastance and cardiac influences during artificial ventilation. The mechanical simulator provides a reproducible and flexible environment for testing new software and equipment in the lung function laboratory and in intensive care, and can be used for instruction and training.

Biomechanical Phenomena↗

Barriers to use of simulation-based education.

PURPOSE: Barriers to simulation-based education in postgraduate and continuing education for anesthesiologists have not been well studied. We hypothesized that the level of training may influence attitudes towards simulation-based education and impact on the use of simulation. This study investigated this issue at the University of Toronto which possesses two sites equipped with high-fidelity patient simulators. METHODS: A 40-question survey of experiences, perceptions, motivations and perceived barriers to simulation-based education, was distributed to 154 anesthesiologists attending a departmental conference. Data were analyzed using descriptive statistics and associations between responses were assessed using either the Chi-Square statistic or a one-way analysis of variance. RESULTS: The rate of response was 58%. Residents had experienced simulation-based education (96%) more often than staff (58%) and fellows (36%), (P < 0.001 respectively). Residents had also attended more simulation sessions than staff and fellows (mean 2.8 vs 1.05 and 1.04, P < 0.001 respectively). Residents and fellows found simulation-based education more relevant for their training than staff (88% vs 65%, P < 0.05). Eighty-one percent of the respondents identified at least one significant barrier that prevents or limits them from attending simulator sessions. Staff anesthesiologists perceived multiple barriers and identified 'time' and 'financial issues' as significant barriers. CONCLUSION: Anesthesiologists' level of training influences their attitudes towards and their perceptions of simulation-based education. This survey has identified perceived barriers that may limit a wider utilization of simulation. These results may be used to implement targeted actions such as course design, incentives, and information strategies, which could improve access and future use of simulation.

Anesthesiology↗

Patient simulation for training basic and advanced clinical skills.

INTRODUCTION: Patient simulators are increasingly used in the education and training of healthcare professionals. This paper describes the history of human patient simulator development, the features of contemporary simulators, the acquisition of basic and advanced clinical skills using patient simulators, and the benefits, cost, limitations and effectiveness of this innovative learning modality. SIMULATOR DEVELOPMENT: The development of human patient simulators began in the late 1960s, and accelerated in the late 1980s and early 1990s. Several simulator systems are now professionally manufactured, commercially available, and used at hundreds of medical centres, universities and colleges in the USA and throughout the world. Contemporary patient simulators have many clinical features, and look and respond to interventions with ever-increasing degrees of realism because sophisticated physiological and pharmacological models automatically control many features. SIMULATOR USE IN MEDICAL EDUCATION: Simulators are used to teach basic skills, such as respiratory physiology and cardiovascular haemodynamics, and advanced clinical skills, e.g. management of difficult airways, tension pneumothorax, pulmonary embolism and shock. BENEFITS, COSTS AND LIMITATIONS: The simulation laboratory offers distinct educational advantages, especially for learning how to recognise and to treat rare, complex, clinical problems. Costs of simulator-based educational programmes include facility, equipment and personnel. Current limitations include clinical realism of the patient manikin and faculty development.

Clinical Competence↗

Development of foetal and neonatal simulators at the University of Porto.

BACKGROUND: Human error can be expected to play a significant role in adverse outcomes in perinatal acute care. In acute care of the adult, simulator based training is recommended and used to improve patient safety. AIMS: Our general goal is to develop model-driven foetal and neonatal educational simulators and curricula. The specific objectives of this paper are to introduce the reader to the perinatal acute care context and simulator design considerations, as well as to give initial results and describe ongoing developments. A brief description of adult simulators and simulation engines is followed by a more detailed description of a foetal distress simulator (FDS) and of models for a neonatal simulator developed at the University of Porto. Ongoing developments involve the modelling of foetal baroreflexes, the effect of uterine contractions, and an adapted method for estimating foetal heart rate variability parameters. RESULTS: We present FDS simulation results reflecting the changes in oxygen supply to the foetus and the foetal heart rate in response to a reduction in uterine blood flow. We also present a structural diagram of a model for the educational simulation of congenital heart disease and preliminary simulation results reflecting a patent ductus arteriosus. CONCLUSION: We expect that, after initial clinical and educational validation, the presented models and simulators will play a role in simulator-based educational programmes contributing to increased perinatal safety.

Clinical Competence↗

Validation of the Monte Carlo simulator GATE for indium-111 imaging.

Monte Carlo simulations are useful for optimizing and assessing single photon emission computed tomography (SPECT) protocols, especially when aiming at measuring quantitative parameters from SPECT images. Before Monte Carlo simulated data can be trusted, the simulation model must be validated. The purpose of this work was to validate the use of GATE, a new Monte Carlo simulation platform based on GEANT4, for modelling indium-111 SPECT data, the quantification of which is of foremost importance for dosimetric studies. To that end, acquisitions of (111)In line sources in air and in water and of a cylindrical phantom were performed, together with the corresponding simulations. The simulation model included Monte Carlo modelling of the camera collimator and of a back-compartment accounting for photomultiplier tubes and associated electronics. Energy spectra, spatial resolution, sensitivity values, images and count profiles obtained for experimental and simulated data were compared. An excellent agreement was found between experimental and simulated energy spectra. For source-to-collimator distances varying from 0 to 20 cm, simulated and experimental spatial resolution differed by less than 2% in air, while the simulated sensitivity values were within 4% of the experimental values. The simulation of the cylindrical phantom closely reproduced the experimental data. These results suggest that GATE enables accurate simulation of (111)In SPECT acquisitions.

Algorithms↗

RadiSeq: a single- and bulk-cell whole-genome DNA sequencing simulator for radiation-damaged cell models.

Objective.To build and validate a simulation framework to perform single-cell and bulk-cell whole genome sequencing simulation of radiation-exposed Monte Carlo (MC) cell models to assist radiation genomics studies.Approach.Sequencing the genomes of radiation-damaged cells can provide useful insight into radiation action for radiobiology research. However, carrying out post-irradiation sequencing experiments can often be challenging, expensive, and time-consuming. Although computational simulations have the potential to provide solutions to these experimental challenges, and aid in designing optimal experiments, the absence of tools currently limits such application. MC toolkits exist to simulate radiation exposures of cell models but there are no tools to simulate single- and bulk-cell sequencing of cell models containing radiation-damaged DNA. Therefore, we aimed to develop a MC simulation framework to address this gap by designing a tool capable of simulating sequencing processes for radiation-damaged cells. Main results.We developed RadiSeq-a multi-threaded whole-genome DNA sequencing simulator written in C++. RadiSeq can be used to simulate Illumina sequencing of radiation-damaged cell models produced by MC simulations. RadiSeq has been validated through comparative analysis, where simulated data were matched against experimentally obtained data, demonstrating reasonable agreement between the two. Additionally, it comes with numerous features designed to closely resemble actual whole-genome sequencing. RadiSeq is also highly customizable with a single input parameter file.Significance.RadiSeq enables the research community to perform complex simulations of radiation-exposed DNA sequencing, supporting the optimization, planning, and validation of costly and time-intensive radiation biology experiments. This framework provides a powerful tool for advancing radiation genomics research.

Monte Carlo Method↗

Validation of a new breathing simulator generating and measuring inhaled aerosol with adult breathing patterns.

The use of breathing simulators for the in vitro determination of the inhaled mass of drug from nebulizers has become widely accepted. Their use is, however, based on the assumption that there is a correlation between the in vitro and in vivo inhaled mass of drug. The aim of the study was therefore to investigate whether a new breathing simulator--the MIMIC Breathing Emulator (Medic-Aid Limited, Bognor Regis, UK)--could accurately emulate the in vivo inhaled mass of budesonide suspension for nebulization. Eight adult healthy subjects were included. Each subject inhaled for 2 min from a Spira Module 1 jet nebulizer (Respiratory Care Center, Hämeenlinna, Finland), charged with 1.0 mg of budesonide suspension for nebulization (0.5 mg mL-1, 2 mL suspension, AstraZeneca, Sweden) and supplied with an inhaled mass filter between the nebulizer and the subject. The breathing patterns were recorded during the nebulization and simulated in vitro at two different experimental sites (simulations A and B) with the breathing simulator. With the patients breathing through the filters (in vivo test), inhaled mass of budesonide averaged 103.6 micrograms. The two in vitro experiments using the simulator revealed similar results with in vitro simulation A equal to 101.0 micrograms and simulation B 99.1 micrograms. There were no statistically significant differences between the in vivo results and those of in vitro simulation A. Results were significantly different for simulation B (p = 0.032) although the difference was less than 4.5%. These data indicate that the breathing simulator can be used to accurately simulate sine waveforms, human breathing patterns, and the in vitro and in vivo inhaled mass of budesonide suspension for nebulization.

Adult↗

Computer simulation of Clostridium botulinum strain 56A behavior at low spore concentrations.

It is generally assumed that spore behavior is independent of spore concentration, but recently published mathematical models indicate that this is not the case. A Monte Carlo simulation was employed in this study to further examine the independence assumption by evaluating the inherent variance in spore germination data. All simulations were carried out with @Risk software. A total of 500 to 4,000 iterations were needed for each simulation to reach convergence. Lag time and doubling time from a higher inoculum concentration were used to simulate the time to detection (TTD) at a lower inoculum concentration under otherwise identical environmental conditions. The point summaries of the simulated and observed TTDs were recorded for the 26 simulations, with kinetic data at the target inoculum concentration. The ratios of the median (R(m) = median(obs)/median(sim)) and 90% range (R(r) = 90% range(obs)/90% range(sim)) were calculated. Most R(m) and R(r) values were greater than one, indicating that the simulated TTDs were smaller and more homogeneous than the observed ones. R(r) values departed farther from one than R(m) values. Ratios obtained when simulating 1 spore with 10,000 spores deviated the farthest from one. Neither ratio was significantly different from the other when simulating 1 spore with 100 spores or simulating 100 spores with 10,000 spores. When kinetic data were not available, the percent positive observed at the 95th percentile of the simulated TTDs was obtained. These simulation results confirmed that the assumption of independence between spores is not valid.

Clostridium botulinum↗

Relationship between obstructive sleep apnoea, driving simulator performance, and risk of road traffic accidents.

BACKGROUND: Obstructive sleep apnoea (OSA) has been shown to be associated with an increased risk of road traffic accidents (RTAs). Predicting the driving ability and risk of RTAs in an individual with OSA is difficult. On-road testing is the gold standard, but this is time consuming, expensive, and potentially dangerous. Simple computer based driving simulators have been developed to help determine driving ability. Although patients with OSA have been shown to perform poorly compared with matched controls, it is not known whether these simulators can predict those at most risk of accidents. In this study we evaluated whether data derived from a simple driving simulator provided information over and above that obtained from the history and a sleep study that might be useful for advising patients about driving. METHODS: We examined 150 patients admitted for routine sleep studies for investigation of OSA and snoring. Each patient performed a 20 minute driving simulation and completed a questionnaire regarding their driving history and experience. RESULTS: Logistic regression analysis was used to investigate factors associated with patients' performance on the simulator. It was found that patient characteristics, older age (OR 1.05, 95% CI 1.01 to 1.09, p<0.01), female sex (OR 9.32, 95% CI 1.09 to 79.4, p<0.04), and self-reported alcohol consumption (OR 1.04, 95% CI 1.01 to 1.07, p<0.01) had the greatest influence; however, the number of self-reported near miss accidents was independently associated with a poor performance (OR 2.62, 95% CI 1.00 to 6.88, p<0.05). A further logistic regression was used to investigate whether clinical history, sleep study results, and data from the driving simulator were useful in classifying patients with OSA as having had an RTA. The number of off-road events per hour on the simulator was independently associated with a history of previous RTA (OR 1.004, 95% CI 1.0004 to 1.008, p<0.03). The Epworth score was independently associated with episodes of falling asleep at the wheel (OR 1.21, 95% CI 1.12 to 1.31, p<0.00001) and near miss accidents (OR 1.15, 95% CI 1.07 to 1.23, p<0.0001). Using this model, 100% of patients who did not have an accident could be identified, but only 10% of those who did. CONCLUSIONS: Although factors not directly related to OSA influence performance on a driving simulator, there is an independent relationship between driving ability in patients with OSA and performance on a simple computer based simulator. When combined with clinical history, it is those not reporting hypersomnolence and not having off-road events on the simulator who appear to be at least risk of adverse driving events. Poor performance on the simulator, however, relates poorly to accident history. These data require confirmation in future studies before simple computer simulators can be used in clinical practice to advise whether an individual is safe to drive.

Accidents, Traffic↗

The uses of simulation in anesthesiology training: a review of the current literature.

Can anesthesia simulation be used successfully in training to improve the abilities of anesthesiologists and so result in decreased morbidity and mortality due to human error? In this review, computer simulation is examined as a training technique to reduce human error during the administration of anesthesia and as a method for studying how anesthetic accidents occur. Simulation is used successfully in other fields, such as aviation pilot training. A discussion of what defines human error will enable understanding of how computer simulation may be used to reduce it. Simulation of the anesthesia environment has been only recently developed. At this time there are at least two simulators which have been developed for the anesthesia environment. The two simulations are different in that one is strictly computer based. One reproduces the anesthesia monitors using computer graphics. The other, the Comprehensive Anesthesia Simulation Environment (CASE) simulation, attempts to reproduce the entire operating room. These two available simulators are discussed. It is presently unknown whether or not the use of simulation in anesthesia training improves the quality of that training. However, simulators necessary to answer this question are either available now or will be in the near future.

Anesthesia↗

Project hydra--a new paradigm of internet-based surgical simulation.

Computer-based surgical simulation systems have produced tremendous benefits and demonstrated validity as a better method for many areas of surgical skills acquisition. However, despite these benefits, broad proliferation of these systems has continued to be elusive. While in large part this lag in adoption of this technology is due to social factors (organizational momentum, curriculum integration difficulties, etc), the cost of computer-based simulation systems has certainly remained a major deterrent toward broad deployment. Instead, what if it were possible to eliminate the cost of the large computer completely from the system, yet provide a much more extensive and detailed simulation than currently available? Finally, what if a simulation with even greater detail over a wider anatomical area were possible?This is the genesis of Project Hydra- a shared simulation supercomputer were made available for free and all that is required to access it is a low-end Internet-connected computer and, optionally, interaction/haptics devices as needed for the particular task. This would enable supercomputer-class simulation at every desktop with much greater fidelity than any user could individually afford and provide an online community for simulation research and application. Further, Internet-based simulation provides for many other benefits as well. By the user merely plugging optional, additional hardware into their existing, low-end PC and using the Internet as a means of simulation dissemination, distribution, and delivery means that the user can have immediate access to simulation updates/upgrades and download/access new content (didactic curriculum and cases). Further, this ease of access and use could lead to accelerated adoption and use of simulation within the medical curriculum and this access is provided anywhere in the world 24 x 7. In addition, once connected, a server-based simulation system would be a natural point for performing easy, automated clinical studies of surgical performance and skills.

Computer Simulation↗

Exploring the energy landscape of protein folding using replica-exchange and conventional molecular dynamics simulations.

Two independent replica-exchange molecular dynamics (REMD) simulations with an explicit water model were performed of the Trp-cage mini-protein. In the first REMD simulation, the replicas started from the native conformation, while in the second they started from a nonnative conformation. Initially, the first simulation yielded results qualitatively similar to those of two previously published REMD simulations: the protein appeared to be over-stabilized, with the predicted melting temperature 50-150K higher than the experimental value of 315K. However, as the first REMD simulation progressed, the protein unfolded at all temperatures. In our second REMD simulation, which starts from a nonnative conformation, there was no evidence of significant folding. Transitions from the unfolded to the folded state did not occur on the timescale of these simulations, despite the expected improvement in sampling of REMD over conventional molecular dynamics (MD) simulations. The combined 1.42 micros of simulation time was insufficient for REMD simulations with different starting structures to converge. Conventional MD simulations at a range of temperatures were also performed. In contrast to REMD, the conventional MD simulations provide an estimate of Tm in good agreement with experiment. Furthermore, the conventional MD is a fraction of the cost of REMD and continuous, realistic pathways of the unfolding process at atomic resolution are obtained.

Protein Folding↗

Bringing good teaching cases "to life": a simulator-based medical education service.

Realistic medical simulation has expanded worldwide over the last decade. Such technology is playing an increasing role in medical education not merely because simulator sessions are enjoyable, but because they can provide an enhanced environment for experiential learning and reflective thought. High-fidelity patient simulators allow students of all levels to "practice" medicine without risk, providing a natural framework for the integration of basic and clinical science in a safe environment. Often described as "flight simulation for doctors," the rationale, utility, and range of medical simulations have been described elsewhere, yet the challenges of integrating this technology into the medical school curriculum have received little attention. The authors report how Harvard Medical School established an on-campus simulator program for students in 2001, building on the work of the Center for Medical Simulation in Boston. As an overarching structure for the process, faculty and residents developed a simulator-based "medical education service"-like any other medical teaching service, but designed exclusively to help students learn on the simulator alongside a clinician-mentor, on demand. Initial evaluations among both preclinical and clinical students suggest that simulation is highly accepted and increasingly demanded. For some learners, simulation may allow complex information to be understood and retained more efficiently than can occur with traditional methods. Moreover, the process outlined here suggests that simulation can be integrated into existing curricula of almost any medical school or teaching hospital in an efficient and cost-effective manner.

Clinical Clerkship↗

Hybrid method coupling molecular dynamics and Monte Carlo simulations to study the properties of gases in microchannels and nanochannels.

We combine molecular dynamics (MD) and Monte Carlo (MC) simulations to study the properties of gas molecules confined between two hard walls of a microchannel or nanochannel. The coupling between MD and MC simulations is introduced by performing MD near the boundaries for accuracy and MC in the bulk because of the low computational cost. We characterize the influence of different densities and molecule sizes on the equilibrium properties of the gas in the microchannel. The effect of the particle size on the simulation results is very small in the case of a dilute gas and increases with the density. The hybrid MD-MC simulation method is validated by comparing the results for density and temperature profiles with those of pure MD and pure MC simulations. These results compare well for pure MD and pure MC, as well as hybrid MD-MC, both in the bulk and near the boundaries, when hard-sphere interactions are used. When Lennard-Jones potentials are used to accurately model the interactions between the gas and wall molecules instead, the results of pure MD simulations differ significantly from the pure MC simulations near the boundaries, but the results of the hybrid method compare well with the pure MD results near the wall, and with the pure MC and pure MD results in the middle of the channel. The hybrid method also very accurately simulates the interface between the MD and MC simulation domains. Comparisons between MD, MC, and hybrid MD-MC computational costs are outlined. The speedup when using 50% of the domain for MD simulations and 50% for MC simulations is very small compared to pure MD simulations times, but this speedup increases drastically for more realistic situations where the region near the wall is small compared to the bulk region.

Journal Article↗

Simulator for neural networks and action potentials: description and application.

1. We describe a simulator for neural networks and action potentials (SNNAP) that can simulate up to 30 neurons, each with up to 30 voltage-dependent conductances, 30 electrical synapses, and 30 multicomponent chemical synapses. Voltage-dependent conductances are described by Hodgkin-Huxley type equations, and the contributions of time-dependent synaptic conductances are described by second-order differential equations. The program also incorporates equations for simulating different types of neural modulation and synaptic plasticity. 2. Parameters, initial conditions, and output options for SNNAP are passed to the program through a number of modular ASCII files. These modules can be modified by commonly available text editors that use a conventional (i.e., character based) interface or by an editor incorporated into SNNAP that uses a graphical interface. The modular design facilitates the incorporation of existing modules into new simulations. Thus libraries can be developed of files describing distinctive cell types and files describing distinctive neural networks. 3. Several different types of neurons with distinct biophysical properties and firing properties were simulated by incorporating different combinations of voltage-dependent Na+, Ca2+, and K+ channels as well as Ca(2+)-activated and Ca(2+)-inactivated channels. Simulated cells included those that respond to depolarization with tonic firing, adaptive firing, or plateau potentials as well as endogenous pacemaker and bursting cells. 4. Several types of simple neural networks were simulated that included feed-forward excitatory and inhibitory chemical synaptic connections, a network of electrically coupled cells, and a network with feedback chemical synaptic connections that simulated rhythmic neural activity. In addition, with the use of the equations describing electrical coupling, current flow in a branched neuron with 18 compartments was simulated. 5. Enhancement of excitability and enhancement of transmitter release, produced by modulatory transmitters, were simulated by second-messenger-induced modulation of K+ currents. A depletion model for synaptic depression was also simulated. 6. We also attempted to simulate the features of a more complicated central pattern generator, inspired by the properties of neurons in the buccal ganglia of Aplysia. Dynamic changes in the activity of this central pattern generator were produced by a second-messenger-induced modulation of a slow inward current in one of the neurons.

Action Potentials↗

Fibromyalgia: can one distinguish it from simulation? An observer-blind controlled study.

OBJECTIVE: A randomized controlled trial was conducted to assess reliability and accuracy in identification of fibromyalgia (FM), motivated simulation, and normal controls. METHODS: Eight female subjects with chronic FM were age matched with 19 healthy female volunteers. The volunteers were randomized to a financially motivated "simulator" group who were paid to simulate FM, or to a "normal control" group. Examiners under blinded conditions rated tender and control points, and illness behavior. Intraclass correlation coefficients and F values showed that counts of tender points significantly discriminated the 3 groups. Variance was mostly due to experimental groups and not to observer or error factors. In this study, simulators could not be discriminated from normals or FM subjects on the basis of tenderness at "control points." Examiner ratings of illness behavior (UAB), and subjects' self-ratings for pain showed that FM subjects had the highest scores, normals the lowest, and simulators had mean scores midway between the mean FM and simulator. On grip strength, the normals obtained the highest scores, the simulators the lowest, and the FM subjects had scores midway between those of the other 2 groups. Diagnostic accuracy of the blinded examiners in distinguishing FM from simulators and from normals was 80%, and for correct diagnosis the kappa value was significant at 0.69. Despite this, simulators were misidentified as FM in 1/3 of judgments, and FM was misidentified as simulators in 1/5 of judgments. CONCLUSION: Under randomized blinded conditions, examiners using the American College of Rheumatology criteria for FM and other bedside observations are able to distinguish chronic FM, normal individuals, and motivated simulators with 80% accuracy, with a good level of agreement and reliability in tender point counts. Our results do not provide a "test for malingering," and it is likely that an important minority of motivated simulators and of FM subjects will be misidentified.

Adult↗

Electrodynamic heart model construction and ECG simulation.

OBJECTIVES: In this paper, we present a unified electrodynamic heart model that permits simulations of the body surface potentials generated by the heart in motion. The inclusion of motion in the heart model significantly improves the accuracy of the simulated body surface potentials and therefore also the 12-lead ECG. METHODS: The key step is to construct an electromechanical heart model. The cardiac excitation propagation is simulated by an electrical heart model, and the resulting cardiac active forces are used to calculate the ventricular wall motion based on a mechanical model. The source-field point relative position changes during heart systole and diastole. These can be obtained, and then used to calculate body surface ECG based on the electrical heart-torso model. RESULTS: An electromechanical biventricular heart model is constructed and a standard 12-lead ECG is simulated. Compared with a simulated ECG based on the static electrical heart model, the simulated ECG based on the dynamic heart model is more accordant with a clinically recorded ECG, especially for the ST segment and T wave of a V1-V6 lead ECG. For slight-degree myocardial ischemia ECG simulation, the ST segment and T wave changes can be observed from the simulated ECG based on a dynamic heart model, while the ST segment and T wave of simulated ECG based on a static heart model is almost unchanged when compared with a normal ECG. CONCLUSIONS: This study confirms the importance of the mechanical factor in the ECG simulation. The dynamic heart model could provide more accurate ECG simulation, especially for myocardial ischemia or infarction simulation, since the main ECG changes occur at the ST segment and T wave, which correspond with cardiac systole and diastole phases.

Electrocardiography↗

Simulation: a strategy for success in quality and safety in pay-for-performance environments.

Pay-for-Performance appears to be another step in our ever-changing healthcare environment. In most of the white papers, reports, and web pages devoted to improving the quality of healthcare in America, there is a failure to recognize or list medical simulation as a methodology to reduce the costs of implementation and to speed transition to the new order. The Agency for Healthcare Research and Quality is funding research in simulation to improve quality. This article outlines the rationales for using simulation and how simulation can benefit all involved. With a paucity of proof that simulation can deliver in terms of improving the quality of healthcare, the mass of evidence has been from observation and anecdotal tales of medical professionals that simulation is a valid tool. This article correlates the use of simulation in other nonmedical pay-for-performance professions to similar situations in medicine as some other evidence that simulation should be considered a viable option. I conclude by relating the individual strengths of simulation to the six quality initiatives of the Institute of Medicine's second report from the Committee on Quality of Health Care in America. Simulation can work to enhance the assimilation of change with each of these initiatives and help to reduce the costs of doing so. There are limitations to simulation, but used within those limitations, simulation should prove to be a powerful tool.

Delivery of Health Care↗