Parameter sensitivity analysis and improvement of a two-layer arterial wall model.

The nonlinear two-layer arterial wall model introduced by von Maltzahn, et al. [11] is subjected to a rigorous parameter sensitivity and range of validity analysis. The model is based on the assumption that in large muscular conduit arteries the two mechanically significant layers are media and adventitia. Using curve-fitting techniques, the media is determined to be isotropic and the adventitia to be anisotropic. As a result of the range of validity analysis, the polynomial relationship for the energy density function of the media is changed to an exponential relationship. This leads to new coefficients for the polynomial of the adventitia. All coefficients have specific mechanical meanings. The parameter sensitivity analysis demonstrates convincingly that all model parameters are significantly important.

Arteries↗

Sensitivity analysis for physiologically based pharmacokinetic models.

The present study evaluates the sensitivity of pharmacokinetic model output to variability in the biochemical and metabolic input parameters. Pharmacokinetic models of three chemicals are chosen for analysis: styrene, methylchloroform, and methylene chloride. Results show that model sensitivities are time-, dose-, and species-dependent and that the most sensitive parameters are the maximum Michaelis-Menten metabolism rate Vmax and the blood/air and fat/air partition coefficients. For humans, the muscle/air partition coefficient is also important. Model output is insensitive to the Michaelis-Menten parameter Km (except for low doses) and to other tissue/air partition coefficients.

Administration, Inhalation↗

Computerized EEG frequency analysis: sensitivity and specificity in patients with focal lesions.

We performed computerized EEG frequency analysis (C-EEGFA) in 69 controls and 20 patients with focal brain lesions and focally abnormal conventional EEGs. Individual channel EEG frequency analysis variables that were helpful in differentiating the 2 groups were absolute delta and theta band power, relative delta, theta, and alpha band powers, and median-power frequency. High-frequency beta band power (20 to 32 Hz) was not useful. Changes in EEG with age were seen only after age 50 and generally consisted of an increase in anterior alpha power, with no significant increase in slowing. Correlations of C-EEGFA variables with posterior alpha power were more significant than correlations with age. Calculating normative C-EEGFA data for 5 subsets of controls, each with a different amount of posterior alpha power, increased the sensitivity of the EEG frequency analysis test without altering the specificity. Even with this correction 2 of 20 patients with focal lesions and focally abnormal conventional EEGs had normal C-EEGFA studies. If these obvious focal lesions produced normal results, more subtle diseases might not be detected. A significant clinical utility of C-EEGFA remains to be proven.

Adult↗

Highly sensitive analysis of multiple pesticides in foods combining solid-phase microextraction, capillary electrophoresis-mass spectrometry, and chemometrics.

A highly sensitive procedure to detect multiple pesticides at trace levels in foods is presented. Initially a comparative study between capillary electrophoresis (CE)-UV and CE-mass spectrometry (MS) is carried out analyzing five pesticides not studied up to now (pyrimethanil, pyrifenox, cyprodinil, cyromazine, and pirimicarb). The comparison between CE-UV and CE-MS is established in terms of separation efficiency, speed of analysis, reproducibility, and sensitivity. A good separation of these compounds is achieved by both techniques using a volatile aqueous buffer containing 0.3 M ammonium acetate/acetic acid at pH 4. Time analysis reproducibility is studied for the same day (n = 5) and three different days (n = 15), showing no significant differences between CE-UV and CE-MS. The study on peak areas reproducibility shows a slightly worse reproducibility for CE-MS compared with CE-UV. The best limit of detection (LOD) that can be achieved for these pesticides using CE-UV was 0.6 microg/mL. CE-MS provides LODs one order of magnitude better than CE-UV. Chemometrics are used to optimize the multiple parameters that play a role in solid-phase microextraction (SPME) and CE-MS analysis (e.g., extraction and desorption times, nebulizer pressure, dry gas flow, dry gas temperature, percentage of organic solvent and acid in the sheath liquid, etc.). The combined use of chemometrics and SPME-CE-MS clearly improves the LODs that can be achieved allowing the detection of pesticides at concentrations down to 15 ng/mL. The usefulness of this approach is demonstrated detecting multiple pesticides in different food samples as grapes and orange juice in a single run. The concentrations detected are below the maximum residue limits (MRLs) permitted for these pesticides in foods corroborating the value of our approach. This work demonstrates, to our knowledge for the first time, the good possibilities of the combined use of SPME-CE-MS and chemometrics.

Absorption↗

Thermo-optical sensitivity analysis in photonic crystal circuits based on semiconducting or metallic metamaterial constituents.

We introduce a novel analysis technique for predicting thermo-optical sensitivities in photonic crystal (PC) circuits composed of either dielectric-semiconducting or metallic constituents. The proposed numerical analysis is based on a hybrid formalism of the scattering matrix technique combined with the adjoint network method. The proposed computational scheme can, with modest computational resources, predict with high accuracy, the effect of the temperature fluctuations to the light-wave propagation in PCs. Numerical simulations show that PC circuits based on metallic metamaterial platforms are significantly less sensitive to temperature variations than the usual dielectricor semiconducting PCs.

Journal Article↗

Sensitivity analysis of a model of mammalian neural membrane.

The sensitivity of the strength-duration (S-D) relationship to changes in the parameters describing the sodium channel of mammalian neuronal membrane was determined by computer simulation. A space-clamped patch of neuronal membrane was modeled by a parallel nonlinear sodium conductance, linear leakage conductance, and membrane capacitance. Each parameter that governs the activation (m) and inactivation (h) variables of the sodium channel was varied from -50% to +50% of its default value, and for each variation a S-D relationship was generated. Individual changes in six of the eleven parameters (alpha mA, alpha mD, alpha hA, beta mA, beta mB, and beta hB) generated substantial changes in the rheobase current and chronaxie time (Tch) of the model. Changing the parameter values individually did not correct for the model's failure to generate excitation after the release from a long duration hyperpolarization (anode break excitation). Scaling a combination of five parameters (alpha mA, alpha mB, alpha hA, beta mA, and beta hB) by an equal amount produced a model that generated anode break excitation and increased Tch, but also decreased the amplitude of the action potential. To reproduce the amplitude of the action potential, the maximum sodium conductance and sodium Nernst potential were increased. These modifications generated a model that had S-D properties closer to experimental results, could produce anode break excitation, and reproduced the action potential amplitude.

Action Potentials↗

Sensitivity analysis and error structure of progress curves.

Both the sensitivity of the monitored signal in progress curves to variations in enzyme concentration and the standard deviation of this signal were analyzed as a function of the proportion of transformed substrate. Three enzymes catalyzing essentially irreversible reactions were used as model systems: HIV-1 protease, glutathione reductase, and glutathione transferase. For all enzymes analyzed, the sensitivity was maximal when 60-80% of the substrate had been transformed. The standard deviation of reaction progress curve data replicates was also maximal at these substrate conversion levels, a result that was attributed to the influence of the sensitivity to random dispersion of the enzyme concentration. On this basis, we developed a model for the standard deviation of reaction progress curves that gave a good description of the experimental data and efficiently reduced the heteroscedasticity of residuals in a weighted fit of progress curves. This standard deviation model can be used for obtaining more efficient parameter estimates, to simulate noise in Monte Carlo procedures, and to delineate detection limits of enzyme inhibition. The transient increases in the sensitivity and in the standard deviation in progress curves are proposed to be features common to most enzymatic assays.

Calibration↗

Sensitive analysis of retinyl esters by isocratic adsorption chromatography.

A sensitive method for the determination of retinyl esters, including their geometric isomers, by isocratic adsorption HPLC is described. The development of a special recycling system allows the separation of all-trans-, 13-cis, 11-cis- and 9-cis-retinyl palmitate, -stearate, -oleate, -palmitoleate and -linoleate with short retention times and high sensitivity. Extraction of the retinyl esters from various organs with mobile phase avoids additional evaporation steps. The method was evaluated by the determination of retinyl esters in small tissue samples such as tongue, trachea and inner ear. This is the first report of the detection of retinyl esters in these tissues, which are known to depend on an adequate vitamin A supply. The main ester in all cases was retinyl palmitate, followed by retinyl stearate and oleate.

Animals↗

Cost benefit analysis of single and dual chamber pacing for sick sinus syndrome and atrioventricular block. An economic sensitivity analysis of the literature.

The benefits of dual (DDD) over single chamber pacing (VVI) have been demonstrated in haemodynamics, exercise capacity, quality of life and reduced complications in atrioventricular block and sick sinus syndrome. The literature was reviewed to provide complication rates for dual and VVI pacing. Cost calculations were based on United Kingdom 1991 prices. Over a 10-year period, a computer model calculated the incidence and prevalence of atrial fibrillation, stroke, permanent disability, heart failure and mortality in six patient categories: sick sinus syndrome paced VVI, sick sinus syndrome upgraded to DDD, sick sinus syndrome paced DDD from outset, atrioventricular block paced VVI and those upgraded to DDD and atrioventricular block paced initially DDD. Calculations were based on intention to treat. The 10 year survival with DDD vs VVI pacing was 71% vs 57% in sick sinus syndrome and 61% vs 51%, respectively, in atrioventricular block. In both indications the prevalence of heart failure in the 10 year survivors was 60% lower with DDD pacing. In sick sinus syndrome patients paced VVI, 36% had severe disability while only 8% experienced this with DDD pacing. For atrioventricular block the figures were, respectively, 22% vs 3%. The difference in 10 year cumulative cost between VVI and DDD is 13 times the purchase price of a VVI pulse generator for sick sinus syndrome and 7 times for atrioventricular block. In the third year after implantation the cumulative costs of DDD were lower than for VVI for both indications. Dual chamber pacing for both indications, sick sinus syndrome and atrioventricular block, is both clinically and cost effective.

Atrial Fibrillation↗

Rapid and sensitive analysis of mRNA polyadenylation states by PCR.

A rapid and sensitive technique is described that measures the length of the poly(A) tail on a specific mRNA within subnanogram quantities of total cellular RNA [the Poly(A) test (PAT)]. In a single-tube reaction, a poly(dT) primer is synthesized in situ on the poly(A) tail of mRNAs using oligo(dT) and DNA ligase. By modulating the annealing temperature and primer concentrations, a GC-rich adapter sequence is targeted to the 5' end of the poly(dT) primer. This ligated poly(dT)-anchor is then used to prime reverse transcription of the mRNA, yielding a library of PAT cDNAs. The length of a poly(A) tail is determined by PCR amplification using the oligo(dT)-anchor primer and a message-specific primer. Comparison of PCR products from different samples allows quantitative determination of changes in polyadenylation of a given mRNA. This technique overcomes many of the pitfalls associated with conventional poly(A) tail length assessments and should prove useful in studying a variety of processes relating to polyadenylation.

Animals↗

Highly sensitive analysis of methamphetamine and amphetamine in human whole blood using headspace solid-phase microextraction and gas chromatography-mass spectrometry.

A simple and highly sensitive method for analysis of derivatized methamphetamine (MA) and amphetamine (AM) in whole blood was developed using headspace solid-phase microextraction (HS-SPME) and gas chromatography-mass spectrometry electron impact ionization selected ion monitoring (GC-MS-EI-SIM). A whole blood sample, deuterated-MA (d(5)-MA), as an internal standard (IS), tri-n-propylamine and pentafluorobenzyl bromide were placed in a vial. The vial was heated and stirred at 90 degrees C for 30min. Then the extraction fiber of the SPME was exposed at 90 degrees C for 30min in the headspace of the vial while being stirred. The derivatives adsorbed on the fiber were desorbed by exposing the fiber in the injection port of a GC-MS. The calibration curves showed linearity in the range of 0.5-1000ng/g for both MA and AM. The time for analysis was about 80min per sample. In addition, this proposed method was applied to two autopsy cases where MA ingestion was suspected. In one case, MA and AM concentrations in the mixed left and right heart blood were 165 and 36.9ng/g, respectively. In the other case, MA and AM concentrations were 1.79 and 0.119 microg/g in the left heart blood, and 1.27 and 0.074 microg/g in the right heart blood, respectively.

Adsorption↗

Input parameter sensitivity analysis and comparison of quantification models for continuous arterial spin labeling.

The regional cerebral blood flow (rCBF) values determined using continuous arterial spin labeling (CASL) are subject to several sources of variability, including natural physiologic variations, sensitivity to the input parameters, and the use of different quantification models. To date, a thorough analysis of the impact of input parameters and the choice of quantification model has not been performed. These sources of variability were investigated through computer simulations using bootstrap techniques on actual CASL data. Coefficients of variation for representative single voxels were 6.7% for gray matter and 29% for white matter, and for eight-voxel regions of interest they were 4.5% for gray matter and 23% for white matter. Comparison of nine CASL quantification models showed differences in gray matter rCBF values of up to 42%. An analysis of the sensitivity of the rCBF to input parameters for each of the nine quantification models demonstrated that accurate quantification of the inversion efficiency, tissue and arterial blood longitudinal relaxation times, and transit times were critical in calculating precise rCBF values. The large potential variations in rCBF and the effect of the choice of quantification model suggest that interpreting absolute rCBF values in CASL studies can be challenging and requires great care.

Adult↗

Direct and sensitive analysis of methamphetamine, ketamine, morphine and codeine in human urine by cation-selective exhaustive injection and sweeping micellar electrokinetic chromatography.

Cation-selective exhaustive injection and sweeping micellar electrokinetic chromatography (CSEI-Sweep-MEKC) was directly used to test some abuse drugs in human urine, including morphine (M), codeine (C), ketamine (K) and methamphetamine (MA). First, phosphate buffer (50 mM, pH 2.5) containing 30% methanol was filled into uncoated fused silica capillary (40 cm, 50 microm I.D.), then high conductivity buffer (100 mM phosphate, 6.9 kPa for 99.9 s) was followed. Electrokinetic injection (10 kV, 500 s) was used to load samples and to enhance sensitivity. The stacking step and separation were performed at -20 kV and 200 nm using phosphate buffer (25 mM, pH 2.5) containing 20% methanol and 100 mM sodium dodecyl sulfate. Using CSEI-Sweep-MEKC, the analytes could be simultaneously analyzed and have a detection limit down to ppb level. It was unnecessary to have sample pretreatments. During method validation, calibration plots were linear (r>or=0.9982) over a range of 150-3,000 ng/mL for M and C, 250-5,000 n g/mL for MA, and 50-1,000 ng/mL for K. The limits of detection were 15 ng/mL for M and C, and 5 ng/mL for MA and K (S/N=3, sampling 500 s at 10 kV). Comparing with capillary zone electrophoresis, the results indicated that this stacking method could increase 6,000-fold sensitivity for analysis of MA. Our method was applied for analysis of 28 real urine samples. The results showed good coincidence with immunoassay and GC-MS. This method was feasible for application to detect trace levels of abused drugs in forensic analysis.

Cations↗

High sensitive analysis of rat serum bile acids by liquid chromatography/electrospray ionization tandem mass spectrometry.

Sensitive liquid chromatography (LC)/electrospray ionization (ESI) tandem mass spectrometry (MS) can be used to analyze the bile acid composition of rat serum. This method can analyze eight common bile acids and their glycine and taurine conjugates in 100 microl rodent serum by gradient elution on a reversed-phase column using a mixture of 20mM ammonium acetate buffer (pH 8.0), acetonitrile and methanol as a mobile phase. Selected reaction monitoring analysis under negative ion detection mode allowed the achievement of a high sensitive assay with a simple solid phase extraction using an ODS cartridge column. We used this method to investigate the effect of a one-day fast on the concentration and composition of serum bile acids in rats. The results suggested that the method described here is useful for the dynamic analysis of serum bile acids in rats.

Animals↗

Sensitivity analysis of segment models to estimate the net reaction moments at the L5/S1 joint in lifting.

This paper deals with the mathematics of inverse dynamic analysis for calculating the net reaction moments; the sensitivity of the net reaction moments to nine experimental values is quantified and two dynamic models are compared. The results indicate that, among all terms, the external forces in the case of a lower body model and the segment masses in the case of an upper body model contributed the most to differences in the sensitivity of the lumbosacral reaction moment about the transverse axis. About the other axes there was no clear difference between the two body models.

Adult↗

Sample purification and preparation technique based on nano-scale reversed-phase columns for the sensitive analysis of complex peptide mixtures by matrix-assisted laser desorption/ionization mass spectrometry.

A simple reversed-phase nano-column purification and sample preparation technique is described, which markedly improves the mass spectrometric analysis of complex and contaminated peptide mixtures by matrix-assisted laser desorption/ionization (MALDI). The method is simple, fast and utilizes only low-cost disposables. After loading the sample on the column and a subsequent washing step, the analyte molecules are eluted with 50-100 nl of matrix solution directly on to the MALDI/MS target. The washing step ensures removal of a wide range of contaminants. The small bed volume of the column allows efficient sample concentration and the elution process yields very small sample spots. This simplifies the analysis and minimizes discrimination effects due to sample heterogeneity, because the desorption/ionization laser simultaneously irradiates a large portion of the sample. Taken together, these features of the method significantly improve the sensitivity for MALDI/MS analysis of contaminated peptide samples compared with the commonly used sample preparation procedures. This is demonstrated with in-gel tryptic digests of proteins from human brain that were separated by 2D gel electrophoresis. Furthermore, it is shown that with this method 2,5-dihydroxybenzoic acid (DHB) acts as an efficient matrix for peptide mapping. Both detection sensitivity and sequence coverage are comparable to those obtained with the currently preferred matrix alpha-cyano-4-hydroxycinnamic acid (CHCA). The higher stability of peptide ions generated with DHB compared with CHCA is advantageous when analyzing fragile sample molecules. Therefore, the method described here is also of interest for the use of Fourier transform ion cyclotron resonance (FT-ICR) or ion-trap mass analyzers.

Animals↗

Micellar electrokinetic chromatography with laser-induced fluorescence detection for rapid and sensitive analysis of two new bioactive reagents using dynamic covalent coating.

A simple, rapid, selective, and sensitive micellar electrokinetic chromatography (MEKC) with laser-induced fluorescence detection (LIF) method was developed, using hexamethyldisilazane (HMDS) as dynamic covalent coating (DCC), for the analysis of two new bioactive agents N-n-hexyl-N'-(sodium p-aminobenzenesulfonate) thiourea (HXPT) and N-n-undecyl-N'-(sodium p-aminobenzenesulfonate) thiourea (UPT) derivatized with 4-chloro-7-nitrobenzo-2-oxa-1,3-diazole. MEKC methods both not using DCC and using DCC were investigated. In a series of optimization steps, DCC and a running buffer of 20 mM Na2B4O7 + 16 mM SDS + 8% acetonitrile were applied for determination of the derivatives. Linear relationships for HXPT and UPT were obtained in the range of 5 to 100 microM (correlation coefficient: 0.9986 for HXPT, 0.9978 for UPT), and the detection limits for HXPT and UPT were 16.5 and 39.0 ng mL(-1). The sensitivity was improved over that of fluorescence spectroscopy methods. The method was applied to the analysis of the two reagents in lab water waste with recoveries in the range of 95.6-107.5%.

Chromatography, Micellar Electrokinetic Capillary↗

Highly sensitive analysis of iodide anion in seaweed as pentafluorophenoxyethyl derivative by capillary gas chromatography.

A simple and sensitive gas chromatography (GC) method is described for the trace analysis of iodide anion (iodide) in processed seaweed as an organic derivative. The method is based on the derivatization of aqueous iodide extracted from seaweed with 2-(pentafluorophenoxy)ethyl 2-(piperidino)ethanesulfonate in toluene using tetra-n-hexylammonium bromide as a phase-transfer catalyst. The resulting pentafluorophenoxyethyl iodide is highly responsive to an electron-capture detector (ECD) and was analyzed by GC-ECD, giving a low detection limit of approximately 2.7 nM (2.7 fmol/microL injected). Interferences of some common anions in the analysis of iodide were studied and proved to be minimal. Application of the method to the analysis of iodide in processed seaweed was performed.