Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “methods”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14Linked to original sources

Analytical methods for sulfonamides in foods and feeds. II. Performance characteristics of sulfonamide methods.

Important factors in interpretation of methods for sulfonamides in tissues are value of the blank, use or omission of recovery factors, and precision of the methods. For determining sulfonamide in tissues, no interlaboratory collaborative studies have been performed to provide reproducibility parameters. By assuming comparability with other tissue residue methods at equivalent concentrations, it may be anticipated that the coefficient of variation within-laboratories of the Bratton-Marshall method is about 15% at concentrations of a fraction of a part per million. It is estimated that the limit of reliable measurement of the Bratton-Marshall method is about 0.2 ppm, varying with the individual laboratory. This value is higher than the tolerance it is intended to enforce. Obviously, the method in this case has been stretched beyond its original claimed capabilities. This method also has high blanks and low recoveries. Assignment of sufficient resources to the solution of the problem by regulatory agencies has resulted in methods capable of handling the sulfonamide residue problem at 0.1 ppm.

Animal Feed↗

[A study of rCBF measurement with autoradiography (ARG) method using N-isopropyl-p-[123I]iodoamphetamine (IMP) and SPECT--comparison of rCBF values between look-up table (TLU) and ARG methods, and evaluation of venous blood samplings as a substitute for arterial blood sampling].

Regional cerebral blood flow (rCBF) values obtained by the TLU method with two 123I-IMP SPECT scans and one point arterial blood sampling and rCBF obtained by the ARG method with one 123I-IMP SPECT scan and fixed distribution volume (Vd) values were compared in 17 cases. A case with post ischemic hyperperfusion or luxury perfusion was not observed in our cases. The correlation coefficients between rCBF values and Vd values obtained by the TLU method were 0.49 (p < 0.001) in 184 ROI without hypoactive areas on the early image, and 0.61 (p < 0.001) in 207 ROI with hypoactive areas, respectively. A high rCBF value with a low Vd value was not observed in any region. Mean Vd value was 44.0 +/- 7.0 (mean +/- SD) in all regions. The correlation coefficients between rCBF values using the TLU method and those using the ARG method with Vd fixed at 44 and 50 were also 0.98. Error of the rCBF value was larger in the region of high rCBF, however, noticeable error of the rCBF value was not observed in the ARG method. The ARG method is more convenient for quantifying rCBF. Venous blood radioactivity at 10 min after 123I-IMP infusion was smaller than arterial blood radioactivity, and the blood activity in the distal vein was larger than that in the proximal vein. The ratio of venous blood activity to arterial blood activity was 0.92 +/- 0.04 (mean +/- SD) at the back of the hand, however, the ratio was a variant in each case. Arterial sampling was thought to be a reliable method to obtain more stable and precise rCBF.

Aged↗

Candidate reference methods for determining target values for cholesterol, creatinine, uric acid, and glucose in external quality assessment and internal accuracy control. I. Method setup.

In Germany, the target values for External Quality Assessment (EQA) and internal accuracy control are determined by Reference Methods for several analytes, including cholesterol, creatinine, uric acid, and glucose. We present candidate Reference Methods for these compounds, based on isotope dilution-gas chromatography--mass spectrometry methods that have been developed at INSTAND, one of the two official Germany EQA reference institutions. Each Reference Method target value is calculated from six independent measurements performed on three different days. The mean method CVs ranged from 0.66% for glucose to 0.96% for creatinine. The inaccuracy (bias) of the methods is < 0.7%, as compared with the Standard Reference Material 909 of the National Institute of Standards and Technology. The maximum total error of a Reference Method value, including the 95% confidence interval and systematic errors, is < 2.3%. The presented candidate Reference Methods have been successfully used to set target values in the German EQA scheme and the internal accuracy control of routine laboratories.

Blood Glucose↗

[The significance of free-type PSA and complex-type PSA in patients with prostatic carcinoma--the characteristics of ACS-PSA method compared with that of Delfia- and Eiken-PSA method].

We studied the clinical significance of free-type prostate specific antigen (PSA) and bound-type PSA in serum of the patients with prostatic carcinoma and benign prostatic hypertrophy. The levels of PSA, gamma-seminoprotein and prostatic acid phosphatase (PAP) in 17 healthy adult males, 20 patients with benign prostatic hypertrophy and 23 patients with prostatic carcinoma were measured by ACS-PSA, Delfia and Eiken-PSA method. The levels of PSA in serum from prostatic carcinoma patients was significantly elevated as compared with that from benign prostatic hypertrophy. Linear regression analysis of the data showed that, although overall correlations were well, different assays gave different PSA concentrations. We have studied the forms of PSA in serum by gel filtration technique and measured PSA levels in each fractions using three methods. Moreover, the characteristics of ACS-PSA method was compared with that of Delfia and Eiken-PSA method. Two peaks of PSA were detected on the elution profiles from three prostatic carcinoma patients sera. Those were estimated complex-type PSA (90kDa) and free-type PSA (30kDa). The complex-type PSA fractions detected by ACS-PSA method were almost identical with that detected by Delfia-PSA method, while free-type PSA fractions detected by ACS-PSA method were greater quantity than those by Delfia and Eiken method. Many factors were contributory to the difference between the assay kits on serum complex-type PSA and free-type PSA levels. The present results suggest that there are some quantitative differences in the immunorecognition of complex-type PSA and free-type PSA between the assay kits.

Adult↗

[Individualized monitoring of the therapy with gentamycin using pharmacokinetic methods. Which method to choose?].

Gentamicin has an excellent cost/efficacy ratio for gram negative infections treatment. Its use is often limited in clinical practice by its narrow safety margins and a high incidence of toxicity. Gentamicin related nephrotoxicity is a major adverse effect, mostly in patients with other concomitant potential risk factors. As many other Authors we have found in our Internal Medicine Service during 1992 a gentamicin related nephrotoxicity incidence of 22.5%. Various empiric methods and nomograms have shown a significant incidence of error in predicting individualized gentamicin dosage regimens. Pharmacokinetics methods have demonstrated much better results regarding efficacy and toxicity. The aim of this prospective study carried out during 1993-1994 was to individualize by pharmacokinetics methods dosage regimens of gentamicin in patients with one or more concomitant risk factors of nephrotoxicity. The purpose of pharmacokinetics dosage regimens has been to achieve trough serum concentrations of gentamicin in therapeutics range-0.5 to 2 micrograms/ml-on the first 24 to 48 hours of treatment, and the maintenance in this range during all the treatment, avoiding both toxic and under therapeutic levels. The incidence of gentamicin related nephrotoxicity has been evaluated in this population. Twenty patients were studied: 18 males and 2 females aged 59.6 years (19 to 85). All had one or more potential risk factors for nephrotoxicity-65 years or more: 13, previous renal failure: 6, other nephrotoxic drugs: 10, diuretics: 4, dehydration: 5, congestive heart failure: 5, diabetes: 3, hypertension: 3. For the first 10 patients gentamicin dosage regimens have been determined by Sawchuk-Zaske pharmacokinetics method and for the subsequent 10 patients by Bayesian method. The two subpopulations had no significant differences regarding mean age, sex and potential risk factors for nephrotoxicity. Results of Sawchuk-Zaske method: 53 trough gentamicin serum concentration were obtained; 86.8% were within the therapeutic range, 7.5% were toxic and 5.7% were under therapeutic. Results of Bayesian method: 44 determinations of gentamicin through concentrations were obtained; 86.3% within therapeutic range, 2.4% were toxic and 11.3% were under therapeutic. A great variability in pharmacokinetic patient's profile has been found and explains the great variability of individualized dosage regimens of gentamicin (30 to 320 mg/day). No patients had gentamicin related nephrotoxicity. Both pharmacokinetics methods lead to a efficient and save employment of gentamicin in patients with previous renal failure and other potential risk factors for nephrotoxicity.

Adult↗

[Comparison of the DNA-GEN Probe PACE 2 method and the LCR method for the detection of Chlamydia trachomatis in the female genital tract].

OBJECTIVE: Comparison of two methods of so-called rapid assessment of Chlamydia trachomatis in the urogenital system, i.e. the hybridization method GEN-Probe PACE 2 and the amplification LCR (ligase chain reaction) method. In 1995-1996 the authors made a screening examination to detect Chlamydiae in the urogenital tract by means of the hybridization method GEN-Probe PACE 2 and the amplification LCR method in selected groups of patients of the Second Gynaecological and Obstetric Clinic, First Faculty Hospital, Prague. The methods were evaluated as to their sensitivity. The examinations of the samples were made in the serological laboratory of the First Dermatological Clinic of the First Faculty Hospital Charles University, Prague. The amplification method is twice as sensitive as the hybridization method.

Adult↗

The regional Monte Carlo method: a dose calculation method based on accuracy requirement.

In this work we propose the regional Monte Carlo (RMC) method of dose calculation. This method combines the Monte Carlo (MC) algorithm and a non-MC algorithm (such as the convolution method) for optimal speed and accuracy in dose calculation for both photon and electron beams and for various irradiation and patient geometries. For specific regions in the geometry where high accuracy is required but difficult to obtain with analytical or empirical calculations, such as critical organs surrounded by complicated inhomogeneities, the MC algorithm is used. For regions with simple geometries, or where a high degree of dose accuracy is not critical, the non-MC algorithm is used to increase speed. There are two aspects of the RMC method. The first one involves determining critical regions and boundaries, and the other involves the actual implementation and mixing of the two computational algorithms. Two examples of different geometries are used to illustrate the different ways to apply the RMC method. The possibility to extend the method to more complicated geometries and inhomogeneities, as well as the ability of the method to incorporate different calculation algorithms, are also discussed.

Algorithms↗

[Studies on the method of measurement of odorants dissolved in water--the simplified head space method].

An improved and simplified Head Space Method was devised for measurement of the concentration of odorants dissolved in waste water, and this method was examined to determine whether it was applicable for this purpose or not. This method is taken into consideration the variableness of liquid concentration and of gas pressure resulting from the volatilization of odorants and aqueous vapor to the atmosphere. By this method, the constants of hydrogen sulfide, dimethylsulfide and trimethylamine were measured under various temperatures and pHs. As a result of comparison with the measured values obtained by the Stripping Method and those from the heretofore used Head Space Method, this method appeared to be fairly applicable.

Hydrogen-Ion Concentration↗

[Comparative study of single-point method and multipoint method in the measurement of estrogen receptor and progesterone receptor in breast cancer].

A comparative study of estrogen receptor (ER) and progesterone receptor (PgR) by single-point method and multi-point method in dextran coated charcoal assay (DCC) was carried out in 50 and 47 cases of breast cancer, respectively. Taking 10 fmol/mg protein as the positive value, the conformation rate of both methods in ER measurement was 96.0% (48/50) with r = 0.978 by linear regression analysis (P less than 0.001). In PgR measurement, the conformation rate of both methods was 95.7% with r = 0.988 (P less than 0.001). Statistically, the difference between single-point method and multi-point method in the ER and PgR measurements was not significant (P greater than 0.5) both in rank-sum test and in paired t-test. The authors suggest that ER and PgR of breast cancer samples be measured with single-point method for its simplicity and less tumor tissue required.

Breast Neoplasms↗

Evaluation of three methods for measurement of femoral neck anteversion. Femoral neck anteversion, definition, measuring methods and errors.

A variety of methods exist for determining femoral neck anteversion. There is, however, no consistent definition or reference method by which the correctness of the measurements can be determined. In this report the precision of a specific definition of femoral neck anteversion is estimated by means of a reference method. Three different radiologic measuring methods based on fundamentally different principles are evaluated by comparison with this reference. It is concluded that: 1) The Dunlap/Rippstein method can be recommended as the standard method. 2) Computed tomography may have substantial sources of error. 3) Methods based on arbitrary projections have poor precision.

Femur Neck↗

[The fecal flora of man. IV. Communication: Comparison of the newly developed method with the old conventional method for the analysis of intestinal flora (author's transl)].

The results of 42 fecal flora analysis of healthy adult men were compared by using a newly developed method and an old conventional method. Statistical estimate indicate, that with the new method the total counts and the counts of bifidobacteria, catenabacteria (eubacteria and anaerobic lactobacilli), peptostreptococci, and clostridia (except Cl. perfringens) as well as the occurences of peptostreptococci and spirillaceae were significant higher than with the use of the old method. On the other hand the counts and occurences of bifidobacteria, veillonellae, Cl. perfringens, Megasphaerae and aerobes were similar with both method. With the new method the total counts of feces of healthy adult men nubmered 1-2 X 10(11) per g wet weight, and fastidious anaerobes, such as bacteroides, catenabacteria and peptostreptococci, were always occurred as predominant flora. The results suggest that the conventional anaerobic jar method is inadequate for the isolation of fastidiuos anaerobes and indicate that the use of modified medium 10 in combination with strict anaerobic technique is necessary for the analysis of fecal flora.

Adult↗

[Comparison of conventional methods for the determination of albumin, transferrin and ceruloplasmin in serum with immunological reference methods (author's transl)].

Radial immunodiffusion, which is a presently accepted reference method, was compared with the mechanized immunoprecipitation. Each of these specific methods was compared with two normal clinical-chemical methods for the determination of albumin and transferrin, and an enzymic method for the determination of ceruloplasmin. The correlation coefficients, the mean slope for regression, and the percentage variation of the average values from those of the average values of the reference methods are presented. In the determination of albumin and ceruloplasmin, radial immunodiffusion and mechanized immunoprecipitation give the same results. Surprisingly, these two specific methods give different results in the determination of transferrin. In as far as there is no doubt concerning the accuracy of the mechanized immunoprecipitation, this method is recommended, since it also has the advantage of being less demanding in cost and time.

Autoanalysis↗

Comparison of linear-scaling semiempirical methods and combined quantum mechanical/molecular mechanical methods for enzymic reactions. II. An energy decomposition analysis.

QM/MM methods have been developed as a computationally feasible solution to QM simulation of chemical processes, such as enzyme-catalyzed reactions, within a more approximate MM representation of the condensed-phase environment. However, there has been no independent method for checking the quality of this representation, especially for highly nonisotropic protein environments such as those surrounding enzyme active sites. Hence, the validity of QM/MM methods is largely untested. Here we use the possibility of performing all-QM calculations at the semiempirical PM3 level with a linear-scaling method (MOZYME) to assess the performance of a QM/MM method (PM3/AMBER94 force field). Using two model pathways for the hydride-ion transfer reaction of the enzyme dihydrofolate reductase studied previously (Titmuss et al., Chem Phys Lett 2000, 320, 169-176), we have analyzed the reaction energy contributions (QM, QM/MM, and MM) from the QM/MM results and compared them with analogous-region components calculated via an energy partitioning scheme implemented into MOZYME. This analysis further divided the MOZYME components into Coulomb, resonance and exchange energy terms. For the model in which the MM coordinates are kept fixed during the reaction, we find that the MOZYME and QM/MM total energy profiles agree very well, but that there are significant differences in the energy components. Most significantly there is a large change (approximately 16 kcal/mol) in the MOZYME MM component due to polarization of the MM region surrounding the active site, and which arises mostly from MM atoms close to (<10 A) the active-site QM region, which is not modelled explicitly by our QM/MM method. However, for the model where the MM coordinates are allowed to vary during the reaction, we find large differences in the MOZYME and QM/MM total energy profiles, with a discrepancy of 52 kcal/mol between the relative reaction (product-reactant) energies. This is largely due to a difference in the MM energies of 58 kcal/mol, of which we can attribute approximately 40 kcal/mol to geometry effects in the MM region and the remainder, as before, to MM region polarization. Contrary to the fixed-geometry model, there is no correlation of the MM energy changes with distance from the QM region, nor are they contributed by only a few residues. Overall, the results suggest that merely extending the size of the QM region in the QM/MM calculation is not a universal solution to the MOZYME- and QM/MM-method differences. They also suggest that attaching physical significance to MOZYME Coulomb, resonance and exchange components is problematic. Although we conclude that it would be possible to reparameterize the QM/MM force field to reproduce MOZYME energies, a better way to account for both the effects of the protein environment and known deficiencies in semiempirical methods would be to parameterize the force field based on data from DFT or ab initio QM linear-scaling calculations. Such a force field could be used efficiently in MD simulations to calculate free energies.

Binding Sites↗

A new method to locate saddle points for reactions in solution by using the free-energy gradient method and the mean field approximation.

A new method for calculating saddle points of reactions in solution is presented. The main characteristics of the method are: (1) the solute-solvent system is described by the averaged solvent electrostatic potential/molecular dynamics method (ASEP/MD). This is a quantum mechanics/molecular mechanics method (QM/MM) that makes use of the mean field approximation (MFA) and that permits one to simultaneously optimize the electronic structure and geometry of the solute molecule and the solvent structure around it. (2) The transition state is located by the joint use of the free-energy gradient method and the mean field approximation. An application to the study of the Menshutkin reaction between NH(3) and CH(3)Cl in aqueous solution is discussed. The accuracy and usefulness of the proposed method is checked through comparison with other methods.

Journal Article↗

Novel ROC-type method for testing the efficiency of multivariate statistical methods in fMRI.

The receiver operating characteristic (ROC) method is a useful and popular tool for testing the efficiency of various diagnostic tests applicable to functional MRI (fMRI) data. Typically, the diagnostic tests are applied on simulated and pseudo-human fMRI data, and the area under the ROC curve is used as a measure of the efficiency of the diagnostic test. The effectiveness of such a method depends on how well the simulated data approximate the real data. For multivariate statistical methods, however, this technique is usually inadequate, as the spatial dependence among voxels is ignored for simulated data. In this work a modified ROC method using real fMRI data with a broader scope is proposed. This method can be applied to most fMRI postprocessing techniques, including multivariate analyses such as canonical correlation analysis (CCA). Also, the relationship of the modified ROC method with the conventional ROC method is discussed in detail.

Algorithms↗

Profile-profile methods provide improved fold-recognition: a study of different profile-profile alignment methods.

To improve the detection of related proteins, it is often useful to include evolutionary information for both the query and target proteins. One method to include this information is by the use of profile-profile alignments, where a profile from the query protein is compared with the profiles from the target proteins. Profile-profile alignments can be implemented in several fundamentally different ways. The similarity between two positions can be calculated using a dot-product, a probabilistic model, or an information theoretical measure. Here, we present a large-scale comparison of different profile-profile alignment methods. We show that the profile-profile methods perform at least 30% better than standard sequence-profile methods both in their ability to recognize superfamily-related proteins and in the quality of the obtained alignments. Although the performance of all methods is quite similar, profile-profile methods that use a probabilistic scoring function have an advantage as they can create good alignments and show a good fold recognition capacity using the same gap-penalties, while the other methods need to use different parameters to obtain comparable performances.

Models, Chemical↗

Measurement of functional residual capacity during mechanical ventilation. Comparison of a computerized open nitrogen washout method with a closed helium dilution method.

The functional residual capacity of patients treated with mechanical ventilation was measured with two methods: the closed helium dilution method and the open nitrogen washout method with a computerized system. Measurements of FRC were made with and without PEEP. The results obtained did not show significant differences between the methods. Additionally we checked the accuracy of the open nitrogen washout method to measure FRC of patients and healthy subjects breathing high concentrations of oxygen which was the same as breathing air. Both methods were equally reliable and safe when measuring the FRC of patients on mechanical ventilation but the nitrogen method was easier and quicker.

Computers↗

Perfusion-Perls and -Turnbull methods supplemented by DAB intensification for nonheme iron histochemistry: demonstration of the superior sensitivity of the methods in the liver, spleen, and stomach of the rat.

Perfusion-Perls and -Turnbull methods supplemented by the intensification with 3,3'-diaminobenzidine (+ DAB) enabled stronger and more extensive staining of nonheme iron than the Perls + and Turnbull + DAB methods carried out on tissue sections fixed with 10% formalin in 0.9% saline or PBS. The section- and perfusion-Perls + DAB methods are not specific for the demonstration of nonheme ferric iron but also stain nonheme ferrous iron. However, owing to its high sensitivity, the perfusion-Perls + DAB method would provide useful information about nonheme iron deposition regardless of oxidation states in normal and pathological conditions. The perfusion-Turnbull + DAB method is specifically demonstrable of nonheme ferrous iron and the results from this method showed significant stores of nonheme ferrous iron in the hepatocytes, Kupffer cells, splenic macrophages, and gastric parietal cells of the rat. Since nonheme ferrous iron is considered to be critically involved in free radical generation, the perfusion-Turnbull + DAB method would visualize such populations of cells that are at risk from free radical damage.

3,3'-Diaminobenzidine↗