Automatic three-dimensional inspection of patient setup in radiation therapy using portal images, simulator images, and computed tomography data.

In external beam radiotherapy, conventional analysis of portal images in two dimensions (2D) is limited to verification of in-plane rotations and translations of the patient. We developed and clinically tested a new method for automatic quantification of the patient setup in three dimensions (3D) using one set of computed tomography (CT) data and two transmission images. These transmission images can be either a pair of simulator images or a pair of portal images. Our procedure adjusts the position and orientation of the CT data in order to maximize the distance through bone in the CT data along lines between the focus of the irradiation unit and bony structures in the transmission images. For this purpose, bony features are either automatically detected or manually delineated in the transmission images. The performance of the method was quantified by aligning randomly displaced CT data with transmission images simulated from digitally reconstructed radiographs. In addition, the clinical performance were assessed in a limited number of images of prostate cancer and parotid gland tumor treatments. The complete procedure takes less than 2 min on a 90-MHz Pentium PC. The alignment time is 50 s for portal images and 80 s for simulator images. The accuracy is about 1 mm and 1 degrees. Application to clinical cases demonstrated that the procedure provides essential information for the correction of setup errors in case of large rotations (typically larger than 2 degrees) in the setup. The 3D procedure was found to be robust for imperfections in the delineation of bony structures in the transmission images. Visual verification of the results remains, however, necessary. It can be concluded that our strategy for automatic analysis of patient setup in 3D is accurate and robust. The procedure is relatively fast and reduces the human workload compared with existing techniques for the quantification of patient setup in 3D. In addition, the procedure improves the accuracy of treatment verification in 2D in some cases where rotational deviations in the setup occur.

Biophysical Phenomena↗

Image acquisition context: procedure description attributes for clinically relevant indexing and selective retrieval of biomedical images.

OBJECTIVE: To support clinically relevant indexing of biomedical images and image-related information based on the attributes of image acquisition procedures and the judgments (observations) expressed by observers in the process of image interpretation. DESIGN: The authors introduce the notion of "image acquisition context," the set of attributes that describe image acquisition procedures, and present a standards-based strategy for utilizing the attributes of image acquisition context as indexing and retrieval keys for digital image libraries. METHODS: The authors' indexing strategy is based on an interdependent message/terminology architecture that combines the Digital Imaging and Communication in Medicine (DICOM) standard, the SNOMED (Systematized Nomenclature of Human and Veterinary Medicine) vocabulary, and the SNOMED DICOM microglossary. The SNOMED DICOM microglossary provides context-dependent mapping of terminology to DICOM data elements. RESULTS: The capability of embedding standard coded descriptors in DICOM image headers and image-interpretation reports improves the potential for selective retrieval of image-related information. This favorably affects information management in digital libraries.

Abstracting and Indexing↗

Liver masses: replacement of conventional T2-weighted spin-echo MR imaging with breath-hold MR imaging.

PURPOSE: To evaluate breath-hold magnetic resonance (MR) imaging with single-shot and multishot T2-weighted fast spin-echo (SE) and inversion-recovery (IR) SE echo-planar (EP) SE (IR-SE-EP) sequences compared with conventional T2-weighted SE imaging for detection of liver masses. MATERIALS AND METHODS: Imaging with all sequences was performed in 32 patients on a 1.5-T whole-body system. Images were compared on the basis of lesion-to-liver contrast-to-noise ratio (C/N), lesion conspicuity, and image quality. Image analysis was performed by two experienced radiologists in consensus. RESULTS: Lesion-to-liver C/Ns were highest on fat-suppressed-half-Fourier-single-shot-fast-SE images. For solid lesions, the lesion-to-liver C/Ns were highest with IR-fast-SE, which was significantly better (P < .05) than IR-SE-EP and conventional SE techniques and also produced the best image quality. Sensitivity with IR-fast-SE was 96%; with fat-suppressed-half-Fourier-single-shot-fast-SE, 92%; with fat-suppressed-fast-SE, 89%; with IR-SE-EP, 83%; and with conventional SE, 78%. CONCLUSION: T2-weighted breath-hold imaging, particularly IR-fast-SE imaging, was more sensitive for hepatic masses than conventional SE imaging, with a substantial reduction in acquisition time. Half-Fourier-single-shot-fast-SE imaging was especially useful in patients who were unable to hold their breath.

Adult↗

Assessment of visually lossless irreversible image compression: comparison of three methods by using an image-comparison workstation.

PURPOSE: To determine the degree of irreversible image compression detectable in conservative viewing conditions. MATERIALS AND METHODS: An image-comparison workstation, which alternately displayed two registered and magnified versions of an image, was used to study observer detection of image degradation introduced by irreversible compression. Five observers evaluated 20 16-bit posteroanterior digital chest radiographs compressed with Joint Photographic Experts Group (JPEG) or wavelet-based trellis-coded quantization (WTCQ) algorithms at compression ratios of 8:1-128:1 and x2 magnification by using (a) traditional two-alternative forced choice; (b) original-revealed two-alternative forced choice, in which the noncompressed image is identified to the observer; and (c) a resolution-metric method of matching test images to degraded reference images. RESULTS: The visually lossless threshold was between 8:1 and 16:1 for four observers. JPEG compression resulted in performance as good as that with WTCQ compression at these ratios. The original-revealed forced-choice method was faster and as sensitive as the two-alternative forced-choice method. The resolution-metric results were robust and provided information on performance above visually lossless levels. CONCLUSION: The image-comparison workstation is a versatile tool for comparative assessment of image quality. At x2 magnification, images compressed with either JPEG or WTCQ algorithms were indistinguishable from unaltered original images for most observers at compression ratios between 8:1 and 16:1, indicating that 10:1 compression is acceptable for primary image interpretation.

Algorithms↗

Hepatic lesion detection and characterization: value of nonenhanced MR imaging, superparamagnetic iron oxide-enhanced MR imaging, and spiral CT-ROC analysis.

PURPOSE: To determine the accuracy for detection and characterization of focal hepatic lesions of nonenhanced, superparamagnetic iron oxide (SPIO)-enhanced, or a combination of nonenhanced and SPIO-enhanced MR imaging and contrast-enhanced spiral computed tomography (CT). MATERIALS AND METHODS: Spiral CT and T2-weighted SPIO-enhanced (ferucarbotran-enhanced) MR imaging were performed in 35 patients within 2 weeks before surgery for malignant hepatic lesions. Only malignant lesions with histopathologic proof were considered. A total of 875 images with and 800 images without focal lesions were presented to five readers, who were asked to assess the presence and characterization of lesions by using a five-point confidence scale. Receiver operating characteristic analysis was performed. RESULTS: Nonenhanced and SPIO-enhanced images together and SPIO-enhanced images alone yielded the best performance for lesion detection. No differences were found among all imaging techniques with regard to lesion characterization (benign vs malignant). The combined approach resulted in larger area under the ROC curve (A(z) = 0.9062) and accuracy (85.3%) (P < 0.02), as compared with SPIO-enhanced MR imaging (A(z) = 0.8667; accuracy, 73.1%). CONCLUSION: SPIO-enhanced T2-weighted MR imaging was more accurate than nonenhanced T1-weighted and T2-weighted MR imaging and contrast-enhanced spiral CT for the detection of focal hepatic lesions. The combined analysis of nonenhanced and SPIO-enhanced images was more accurate in the characterization of focal hepatic lesions than was review of SPIO-enhanced images alone.

Contrast Media↗

Parametric ultrasound imaging from backscatter coefficient measurements: image formation and interpretation.

A broadband method for measuring backscatter coefficients sigma b and other acoustic parameters is described. From the sigma b measurements, using a commercially-available imaging system, four high-resolution parametric ultrasound images are formed in a C-scan image plane. Scatterer size images are computed from the frequency dependence of sigma b and a correlation model function that describes the structure and elastic properties of the medium. Scattering strength images are computed from the absolute magnitude of sigma b. Chi-square images are generated to display how well the correlation model represents the interrogated medium. Integrated backscatter coefficient images are formed over the transducer bandwidth. All four images are generated simultaneously and compared with the corresponding B-mode image. Test samples with known physical properties were used to demonstrate experimentally that accurate parametric images are possible if an accurate correlation model is used. Local variations in attenuation, the center frequency and bandwidth of the transducer, and the distribution of scatterer sizes greatly influence the accuracy of estimates and the appearance of the image, thus demonstrating the importance of these factors in parametric image interpretation.

Agar↗

Filter for biomedical imaging and image processing.

Image filtering techniques have numerous potential applications in biomedical imaging and image processing. The design of filters largely depends on the a priori, knowledge about the type of noise corrupting the image. This makes the standard filters application specific. Widely used filters such as average, Gaussian, and Wiener reduce noisy artifacts by smoothing. However, this operation normally results in smoothing of the edges as well. On the other hand, sharpening filters enhance the high-frequency details, making the image nonsmooth. An integrated general approach to design a finite impulse response filter based on Hebbian learning is proposed for optimal image filtering. This algorithm exploits the interpixel correlation by updating the filter coefficients using Hebbian learning. The algorithm is made iterative for achieving efficient learning from the neighborhood pixels. This algorithm performs optimal smoothing of the noisy image by preserving high-frequency as well as low-frequency features. Evaluation results show that the proposed finite impulse response filter is robust under various noise distributions such as Gaussian noise, salt-and-pepper noise, and speckle noise. Furthermore, the proposed approach does not require any a priori knowledge about the type of noise. The number of unknown parameters is few, and most of these parameters are adaptively obtained from the processed image. The proposed filter is successfully applied for image reconstruction in a positron emission tomography imaging modality. The images reconstructed by the proposed algorithm are found to be superior in quality compared with those reconstructed by existing PET image reconstruction methodologies.

Algorithms↗

MR imaging of the temporomandibular joint: comparison of images of autopsy specimens made at 0.3 T and 1.5 T with anatomic cryosections.

We made MR images of 39 autopsy specimens of the temporomandibular joint at 0.3 and 1.5 T and compared the images with anatomic cryosections. Imaging time and slice thickness were the same on scans made at each field strength. The purpose was to determine which field strength provides the best scans for imaging of the joint. Additionally, we used imaging times two and four times longer on the 0.3-T scanner to assess to what extent image quality and diagnostic accuracy could be improved. The cryosections showed that 27 of the joints were normal. Twelve had disk displacements. Ten of the joints with disk displacement also had disk deformities, and seven had bony abnormalities. Investigators who analyzed the MR images had no knowledge of the findings on the cryosections. The disk position, disk configuration, and bony abnormalities were correctly diagnosed in 85%, 77%, and 100%, respectively, on 1.5-T MR images compared with 46%, 41%, and 85%, respectively, on the 0.3-T images. When the imaging time was increased by a factor of four, the accuracy rate on the 0.3-T system became comparable to that of the 1.5-T MR scanner: 73% for disk position, 67% for disk configuration. The results suggest that the diagnostic quality of MR images of the temporomandibular joint is better on scans made at 1.5 T than on those done at 0.3 T when comparable imaging times are used.

Aged↗

Fat-suppressed three-dimensional spoiled gradient-echo MR imaging of hyaline cartilage defects in the knee: comparison with standard MR imaging and arthroscopy.

OBJECTIVE: The sensitivity of fat-suppressed three-dimensional spoiled gradient-echo (SPGR) images was compared with that of standard MR images for detecting hyaline cartilage defects of the knee, using arthroscopy as the standard of reference. SUBJECTS AND METHODS: We assessed 114 consecutive patients for hyaline cartilage defects of the knee with both standard MR imaging sequences and a sagittal fat-suppressed three-dimensional SPGR sequence. Of these patients, 48 with meniscal or ligament injury, or persistent symptoms, underwent subsequent arthroscopy. The standard MR images and SPGR images of these 48 patients were then retrospectively analyzed for articular defects in a blinded fashion by two independent observers. Sensitivity, specificity, and intraobserver and interobserver agreement were determined for the different imaging techniques. RESULTS: One fourth of the patients who went on to arthroscopy were shown to have isolated hyaline cartilage lesions that were clinically confused with meniscal tears and that were missed on the standard MR images. When looking at all surfaces combined for each reader, the SPGR imaging sequence had a significantly higher sensitivity than the standard MR imaging sequences for detecting hyaline cartilage defects (75-85% versus 29-38%, p < .001 for each comparison). When looking at individual surfaces for each reader, significant differences in sensitivity were shown for each surface except the trochlear and lateral tibial surfaces. We found no difference in specificity (97% versus 97%, p > .99). We also found that combined evaluation of standard MR and SPGR images gave no added diagnostic advantage (sensitivity, 86%; specificity, 97%; p > .42). Except for the lateral tibial surface, the study achieved excellent reproducibility among readings and between readers. CONCLUSION: Fat-suppressed three-dimensional SPGR imaging is more sensitive than standard MR imaging for the detection of hyaline cartilage defects of the knee.

Adolescent↗

Multishot echoplanar MR imaging of the female pelvis: comparison with fast spin-echo MR imaging in an initial clinical trial.

OBJECTIVE: The purpose of this study was to apply multishot echoplanar MR imaging (EPI) to the female pelvis and compare image quality with that of fast spin-echo MR imaging. SUBJECTS AND METHODS: Twenty-one patients with suspected pelvic disease and five healthy female volunteers were prospectively examined. MR imaging was obtained using an EPI-capable 1.0-T imager and a pelvic phased-array coil. Axial EPI and fast Spin-echo sequences were obtained at identical image locations in each patient and volunteer. Spin-echo EPI images were obtained using a multishot number of 16. Acquisition time for each EPI sequence was 2 min 10 sec. Fat-suppressed T2-weighted fast spin-echo images were obtained in 2 min 12 sec. Paired EPI and fast spin-echo MR images were independently evaluated by three reviewers. RESULTS: Delineation of the perivaginal and parametrial venous plexus on EPI was rated superior to the fast spin-echo images in 62 (77%) of 81 cases. On EPI, uterine zone anatomy and ovary visualization were judged to be inferior in 44 (56%) of 78 cases and in 18 (33%) of 54 cases, respectively. For delineation of uterine abnormalities, including leiomyoma and adenomyosis, both sequences performed almost equally well. However, ovarian cystic lesions were revealed more precisely by the fast spin-echo sequence. An overall fat-suppression effect was seen on EPI images in 62 (77%) of 81 cases. CONCLUSION: Multishot EPI cannot replace fast spin-echo sequences for imaging the female pelvis; however, because EPI has a potent fat-suppression effect and heavily T2-weighted contrast, EPI sequences can be a valuable adjunct to routine examination.

Echo-Planar Imaging↗

Image resolution and signal-to-noise ratio requirements for MR imaging of degenerative cartilage.

OBJECTIVE: The purpose of this study was to determine the MR image resolution and signal-to-noise ratio (SNR) required to reveal morphologic abnormalities in degenerative cartilage. MATERIALS AND METHODS: In vitro MR microscopy of healthy bovine and degenerative human patellar cartilage was performed and image resolution degraded to simulate resolution achievable in routine and optimized clinical MR images. Noise was then added to images as in-plane resolution was increased to simulate the MR imaging appearance of cartilage with improved resolution, which is possible using a standard magnetic field strength. MR images of patellar cartilage from a healthy volunteer were also obtained to determine optimal SNR and image resolution achievable at 1.5 T; these images were compared with in vitro images to determine those features of abnormal cartilage that can be identified using available clinical MR imaging techniques. RESULTS: In-plane resolution of 39 microns exquisitely defines degenerative changes in articular cartilage. As in-plane resolution decreases to 600 microns, only gross cartilage thinning and signal intensity alterations are seen. MR images simulating progressively improved resolution using higher field strength gradients with conventional field strengths and RF coils provided suboptimal information because of low SNR. CONCLUSION: Routine clinical MR images do not accurately reveal early degenerative changes in articular cartilage; only large defects and distorted changes in the signal intensity of cartilage are seen.

Adult↗

Registration of three-dimensional left atrial computed tomographic images with projection images obtained using fluoroscopy.

BACKGROUND: Anatomic structures such as the left atrium and the pulmonary veins (PVs) are not delineated by fluoroscopy because there is no contrast differentiation between them and the surrounding anatomy. Representation of an anatomic structure via a 3D model obtained from computed tomography (CT) imaging and subsequent projection of these images over the fluoroscopy system may help in navigation of the mapping and ablation catheter to the appropriate sites during electrophysiology procedures. METHODS AND RESULTS: In this feasibility study, in vitro experiments were performed with a plastic heart model (phantom) with 2 catheters or radiopaque platinum beads placed in the phantom at the time of CT imaging and fluoroscopy. Subsequently, 20 consecutive patients underwent contrast-enhanced, ECG-gated CT scanning. Left atrial volumes were generated from the reconstructed data at &75% of the R-R interval during the cardiac cycle. Similarly, the superior vena cava and the coronary sinus were also reconstructed from these images. During the electrophysiology procedure, digital records (cine sequences) were obtained. Using predetermined algorithms, both the phantom model and the patients' 3D left atrial models derived from the CT were registered with projection images of fluoroscopy. Registration was performed with a transformation that linked the superior vena cava and the coronary sinus from the CT model with a catheter placed inside the coronary sinus via the superior vena cava. Registration was successfully accomplished with the plastic phantom and in all 20 patients. Registration accuracy was assessed in the phantom by assessing the overlapping beads seen both in the CT and the fluoroscopy images. The mean registration error was 1.4 mm (range 0.9 to 2.3 mm). Accuracy of the registered images was assessed in patients with recordings from a basket catheter placed sequentially in the superior PVs and by injecting contrast into the PVs to assess overlapping of contrast-filled PVs with the corresponding vessels on the registered images. The images could be calibrated quite accurately. Any rotational error, which was usually minor, could be corrected by rotating the images as needed. CONCLUSIONS: Registration of 3D models of the left atrium and PVs with fluoroscopic images of the same is feasible and could enable appropriate navigation and localization of the mapping and ablation catheter during procedures such as atrial fibrillation ablation.

Aged↗

[Clinical aspects of image quality and doses in gated pulsed imaging].

PURPOSE: The relations between image quality in last image hold images and dose in grid controlled fluoroscopy in comparison to the continuous mode need to be characterised and recommendations for the clinical application of this technique should be given. MATERIAL AND METHODS: Spatial resolution, signal-noise ratio and, contrast-detail visibility were evaluated by phantom measurements in grid controlled pulsed and continuous fluoroscopy. Dose was measured at the image intensifier entrance. Image quality of last image hold (LIH) images of clinical examinations was graded in relation to single shot exposures. RESULTS: Signal-noise ratio and contrast-detail visibility depend on the dose per puls. Spatial resolution and contrast-detail visibility in grid controlled fluoroscopy are superior than to in the continuous mode. Image quality of the LIH images from the grid controlled fluoroscopy was improved. Radiation exposure could be reduced to 10-46%. CONCLUSIONS: Combinations of puls-dose and -frequency are recommended for achieving extensive dose reduction and improved image quality of LIH images.

Diagnostic Imaging↗

[Clinical usage of parallel imaging of head three-dimensional MR image for analysis of VSRAD: a comparison of imaging statistical analytic results in SENSE acquisition method shortening acquisition time versus conventional acquisition method].

Voxel-based Specific Regional Analysis System for Alzheimer's Disease (VSRAD) has developed recently as an adjunctive diagnostic tool for early Alzheimer-type dementia (ATD), using three-dimensional (3D) MRI with statistical parametric mapping (SPM), and for the objective evaluation of brain atrophy. However, it takes more than five minutes to acquire MRI data by the 3D gradient echo method (3D FFE), resulting in low-throughput performance and motion artifact. These problems interrupt the application of daily MRI study. In this study, we recruited 20 patients suspected of having ATD who then underwent continuous 3D FFE MRI studies with and without the SENSE method. It was found that the VSRAD results of MRI data with SENSE were nearly to equal to those without SENSE, in spite of the prediction of a decline in source-to-noise ratio due to the reduction factor in the SENSE method.

Aged↗

Image compression and chest radiograph interpretation: image perception comparison between uncompressed chest radiographs and chest radiographs stored using 10:1 JPEG compression.

We have assessed the effect of 10:1 lossy (JPEG) compression on six board-certified radiologists' ability to detect three commonly seen abnormalities on chest radiographs. The study radiographs included 150 chest radiographs with one of four diagnoses: normal (n = 101), pulmonary nodule (n = 19), interstitial lung disease (n = 19), and pneumothorax (n = 11). Before compression, these images were printed on laser film and interpreted in a blinded fashion by six radiologists. Following an 8-week interval, the images were reinterpreted on an image display workstation after undergoing 10:1 lossy compression. The results for the compressed images were compared with those of the uncompressed images using receiver operating characteristic (ROC) analyses. For five of six readers, the diagnostic accuracy was higher for the uncompressed images than for the compressed images, but the difference was not significant (P > .1111). Combined readings for the uncompressed images were also more accurate when compared with the compressed images, but this difference was also not significant (P = .1430). The sensitivity, specificity, and accuracy values were 81.5%, 89.2%, and 86.7% for the compressed images, respectively, as compared with 78.9%, 94.5%, and 89.3% for the uncompressed images. There was no correlation between the readers' accuracy and their experience with soft-copy interpretation; the extent of radiographic interpretation experience had no correlation with overall interpretation accuracy. In conclusion, five of six radiologists had a higher diagnostic accuracy when interpreting uncompressed chest radiographs versus the same images modified by 10:1 lossy compression, but this difference was not statistically significant.

Humans↗

Effect of temporal subtraction images on radiologists' detection of lung cancer on CT: results of the observer performance study with use of film computed tomography images.

RATIONALE AND OBJECTIVES: To evaluate the effect of temporal subtraction images on the radiologists' detection of early primary lung cancer in computed tomography (CT) scans. MATERIALS AND METHODS: Fourteen cases with primary lung cancer and 16 normal cases were used for this study from a database of low-dose CT images, which were obtained from a lung cancer screening program in Nagano, Japan. Images were obtained with a single-detector helical CT scanner using 10 mm collimation and 2:1 pitch. Each case had both previous and current CT scans. Temporal subtraction images were obtained by subtracting the warped previous images from the current images. Seven radiologists, including four attendings and three residents, provided their confidence levels for the presence or absence of lung cancers with use of film CT images without and with temporal subtraction images. Receiver operating characteristic analysis was used to compare their performance without and with temporal subtraction images. RESULTS: The mean Az values (area under the receiver operating characteristic curve) of seven observers without and with temporal subtraction images were 0.868 and 0.930, respectively. Diagnostic accuracy was significantly improved by using temporal subtraction images (P = .007). Temporal subtraction images were especially useful when a nodule was present near the pulmonary hilum, where radiologists tended to overlook it. CONCLUSION: The temporal subtraction technique can significantly improve the sensitivity and specificity for detection of lung cancer on CT scans.

Adult↗

Optimal image resolution for digital storage of radiotherapy-planning images.

PURPOSE: To evaluate the quality of digitized radiation-planning images at different resolution and to determine the optimal resolution for digital storage. METHODS AND MATERIALS: Twenty-five planning films were scanned and digitized using a film scanner at a resolution of 72 dots per inch (dpi) with 8-bit depth. The resolution of scanned images was reduced to 48, 36, 24, and 18 dpi using computer software. Image qualities of these five images (72, 48, 36, 24, and 18 dpi) were evaluated and given scores (4 = excellent; 3 = good; 2 = fair; and 1 = poor) by three radiation oncologists. An image data compression algorithm by the Joint Photographic Experts Group (JPEG) (not reversible and some information will be lost) was also evaluated. RESULTS: The scores of digitized images with 72, 48, 36, 24, and 17 dpi resolution were 3.8 +/- 0.3, 3.5 +/- 0.3, 3.3 +/- 0.5, 2.7 +/- 0.5, and 1.6 +/- 0.3, respectively. The quality of 36-dpi images were definitely worse compared to 72-dpi images, but were good enough as planning films. Digitized planning images with 72- and 36-dpi resolution requires about 800 and 200 KBytes, respectively. The JPEG compression algorithm produces little degradation in 36-dpi images at compression ratios of 5:1. CONCLUSION: The quality of digitized images with 36-dpi resolution was good enough as radiation-planning images and required 200 KBytes/image.

Humans↗