Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “WELDING”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14Linked to original sources

Welding of gallbladder tissue with a pulsed 2.15 microns thulium-holmium-chromium:YAG laser.

Percutaneous endoscopic approaches to cholelithiasis would be facilitated by methods for welding gallbladder tissues. We evaluated the bursting pressure and histologic appearance of canine gallbladder tissue welded with a thulium-holmium-chromium:YAG (THC:YAG) laser producing a 2.15 microns pulsed output. The tissue absorption characteristics at this wavelength as well as the pulsed nature of the output permit tissue welding with limited collateral thermal damage. The THC:YAG is compatible with a flexible fiberoptic delivery system. Bursting strengths of the welded junctions averaged 42 mm Hg, which is above physiologically encountered pressures. Histologic sections of the bonded tissues revealed tissue fusion and limited thermal injury to the surrounding tissue. We feel that THC:YAG laser welding may be a useful technique in the clinical development of percutaneous endoscopic biliary surgery.

Animals↗

Comparative in vitro study of tissue welding using a 808 nm diode laser and a Ho:YAG laser.

In vitro porcine arteries and veins have been welded end-to-end using either a 808 nm diode laser combined with an indocyanine green enhanced albumin solder, or with a continuous-wave (cw) Ho:YAG laser without biological solder. The vascular stumps were approached to each other over a coronary dilatation catheter in order to obtain a precise alignment and good coaptation. Standard histology revealed for both welding techniques lateral tissue damage between 2 and 3 mm caused by laser-induced heat. Good solder attachment to the tissue was observed by the use of a scanning electron microscope. The vessels soldered with the 808 nm diode laser using albumin solder showed considerably higher tensile strength (1 N compared to 0.3 N) than vessels welded exclusively by Ho:YAG laser radiation. In contrast, leaking pressure (350 +/- 200 mmHg) and bursting pressure (457 +/- 200 mmHg) were found to be independent of the welding technique used. This study demonstrates that fast (total welding time about 2-5 min), stable and tight microvascular anastomosis can be achieved with the use of a dye-enhanced albumin laser soldering technique and an ancillary coronary dilatation catheter.

Anastomosis, Surgical↗

Laser tissue welding in genitourinary reconstructive surgery: assessment of optimal suture materials.

OBJECTIVES: Laser tissue welding in genitourinary reconstructive surgery has been shown in animal models to decrease operative time, improve healing, and decrease postoperative fistula formation when compared with conventional suture controls. Although the absence of suture material is the ultimate goal, this has not been shown to be practical with current technology for larger repairs. Therefore, suture-assisted laser tissue welding will likely be performed. This study sought to determine the optimal suture to be used during laser welding. METHODS: The integrity of various organic and synthetic sutures exposed to laser irradiation were analyzed. Sutures studied included gut, clear Vicryl, clear polydioxanone suture (PDS), and violet PDS. Sutures were irradiated with a potassium titanyl phosphate (KTP)-532 laser or an 808-nm diode laser with and without the addition of a light-absorbing chromophore (fluorescein or indocyanine green, respectively). A remote temperature-sensing device obtained real-time surface temperatures during lasing. The average temperature, time, and total energy at break point were recorded. RESULTS: Overall, gut suture achieved significantly higher temperatures and withstood higher average energy delivery at break point with both the KTP-532 and the 808-nm diode lasers compared with all other groups (P < 0.05). Both chromophore-treated groups had higher average temperatures at break point combined with lower average energy. The break-point temperature for all groups other than gut occurred at 91 degrees C or less. The optimal temperature range for tissue welding appears to be between 60 degrees and 80 degrees C. CONCLUSIONS: Gut suture offers the greatest margin of error for KTP and 808-nm diode laser welding with or without the use of a chromophore.

Evaluation Studies as Topic↗

Comparison of ultrasonic suture welding and traditional knot tying in a rabbit rotator cuff repair model.

The purpose of this study is to evaluate ultrasonic suture welding of monofilament suture in an animal model of rotator cuff repair with biomechanical and histologic analyses. We randomly assigned 46 shoulders in 23 rabbits to 1 of 3 treatment groups: sham-operated (n = 15), knotted (n = 15), and welded (n = 16). Supraspinatus defects were surgically created and acutely repaired with suture anchors loaded with either No. 2-0 Ethibond for knotted group or No. 2-0 nylon for welded shoulders. Eighteen weeks postoperatively, all animals were killed, and the shoulders underwent either biomechanical testing or histologic analysis. The maximum stress of the sham-operated group (20.6 N/mm2) was significantly greater than that of both the knotted (10.2 N/mm2) and welded (8.3 N/mm2) groups (P < .05), but no differences were observed between the knotted and welded groups. Although some histologic changes were noted, none was considered to be significant to distinguish either group.

Animals↗

Characteristics of coated copper wire specimens using high frequency ultrasonic complex vibration welding equipments.

Welding characteristic of thin coated copper wires were studied using 40, 60, 100 kHz ultrasonic complex vibration welding equipments with elliptical to circular vibration locus. The complex vibration systems consisted of a longitudinal-torsional vibration converter and a driving longitudinal vibration system. Polyurethane coated copper wires of 0.036 mm outer diameter and copper plates of 0.3 mm thickness and the other dimension wires were used as welding specimens. The copper wire part is completely welded on the copper substrate and the insulated coating material is driven from welded area to outsides of the wire specimens by high frequency complex vibration.

Journal Article↗

Technical frontiers for the vascular surgeon: laser anastomotic welding and angioscopy-assisted intraluminal instrumentation.

Innovations in therapy for peripheral vascular disease include laser vessel welding and angioscopy-assisted intraluminal laser instrumentation. Vascular tissue fusion by laser occurs at energy levels lower than those required to coagulate or vaporize. CO2, argon, and Nd:YAG (1.06 micron) lasers have all been reported to fuse anastomoses in microvessels, but adequate welding of larger veins and arteries (3 to 8 mm in diameter) has only been accomplished with the argon laser. Laser welds heal comparably to sutured wounds but do not have the chronic foreign body reaction and disorientation of elastin and collagen associated with sutures. Preliminary evidence suggests that argon laser-welded anastomoses have less intimal hyperplasia than sutured anastomoses. Laser welding may also be a useful adjunct for sealing intimal flaps during endarterectomy. Additional work is needed to determine the mechanism, optimal parameters, and wavelengths required for vascular tissue fusion by laser. Direct application of laser light intraluminally has thus far been associated with a high incidence of vessel perforation. Angioscopy-assisted delivery of a metal hot-tip probe shows promise for angioplasty of occluded medium-sized arteries and for valvulotomy in in situ vein bypasses.

Animals↗

Lead, chromium, tin, iron and cadmium in foods in welded cans.

The levels of lead, chromium, tin, iron and cadmium in fruit and vegetables in welded tinplate cans were determined by atomic absorption spectrophotometry. The levels found were compared with those in foods in soldered tinplate cans and fresh foods. The results show that the lead levels in foods in welded cans were much lower than those in similar foods in soldered cans. Foods in unlacquered welded cans contain much more lead, chromium and tin than foods in lacquered welded cans. The cadmium and iron levels in canned fruit and vegetables in welded cans were similar to those found in the corresponding fresh foods.

Cadmium↗

Fluorescence spectroscopic imaging to detect changes in collagen and elastin following laser tissue welding.

OBJECTIVE: A study was performed to evaluate the use of native fluorescence imaging to detect in situ molecular changes. SUMMARY BACKGROUND DATA: There is no ideal noninvasive method to monitor molecular changes in a local region at a laser weld joint without removing a section of tissue for histological examination. METHODS: Two sections of animal skin were welded together border to border using a Ti:sapphire laser beam (800 nm). Fluorescence imaging was performed on the cross section of the welded site at specific emission wavelengths (lambda c) for collagen at 380 nm and for elastin at 450 nm using excitation wavelengths (lambda e) of 340 nm, and 380 nm, respectively. RESULTS: A reduction of the collagen and elastin emission was observed in the fluorescence images of the welded region. These results were confirmed with histology using picrosirius red F3BA under polarized light and orcein stains. CONCLUSION: Optical spectroscopic imaging offers a new noninvasive detecting method for microscopic evaluation of laser tissue welding.

Animals↗

Does bipolar electrocoagulation time affect vessel weld strength?

The value of the bipolar electrocoagulator in the haemostasis of bleeding ulcers is controversial. We have therefore investigated the effect of different coagulation times on vessel weld strength achieved by the bipolar device. Welds were then made in vessels of known diameter using a standard 10F endoscopic haemostatic probe at coagulation times of two and 20 seconds. The intravascular temperature achieved at each time was measured. Vessel weld strength achieved by bipolar electrocoagulation was much greater at 20 seconds (approximately twice that at two seconds) and was highly significantly greater at all vessel diameters. There was a gradual reduction in weld strength with increasing vessel diameter, an effect that was seen for both two and 20 seconds of electrocoagulation. Intravascular temperature was significantly higher at 20 seconds than at two seconds. We conclude that vessel weld strength is related to coagulation time and that any future studies comparing the bipolar electrocoagulator with other haemostatic devices should use longer periods of bipolar electrocoagulation and record the coagulation time in order to optimise the clinical value of the device.

Animals↗

Use of the laser for welding cracks on the dental enamel.

An all line argon laser beam of initial power 2W (4000W/cm2-800 J/cm2, after focusing), was used to weld enamel cracks on extracted human teeth. The welding, observed with the naked eye, caused a small heightening in the welded area which was whiter in color than the rest of the enamel. Examinations were performed on the outer surface of the welding with an inverted metallurgical microscope and using a microdurometer. Sections were then made and studied, on the one hand with a light microscope, and on the other using microradiographical methods. The welding was seen to reach across half the enamel thickness. The possibilities for therapeutic applications of this work are discussed.

Argon↗

Laser-welded ureteral anastomoses: experimental studies with three techniques.

Tissue welding with laser energy is a new technique for reconstructive surgery. The potential advantages of laser welding are (a) lack of foreign body reaction, (b) decreased operative time, (c) less tissue manipulation, and (d) effective union of tissues equivalent to sutured anastomoses. We have performed ureteral anastomoses in adult mongrel dogs using a KTP 532 nm laser at an intensity of 1.4 W. Multiple "spot welds" of 1-s duration were utilized in a single layer anastomosis. Laser-welded anastomoses were performed with and without protein solder (33% and 50% human albumin) and were compared to sutured anastomoses. The laser-welded anastomoses required less operative time and provided bursting pressure levels similar to those of traditional sutured anastomoses. There was no advantage or disadvantage to the addition of human albumin as a solder in these experimental studies.

Anastomosis, Surgical↗

Cross-shift and chronic effects of stainless-steel welding related to internal dosimetry of chromium and nickel.

Ninety welders from a stainless-steel fabricating plant were studied by pulmonary function tests and serum and urine chromium and nickel levels, cross-sectionally, and 31 were compared across a Monday shift. They had welded for a mean of 11 years, mean age was 44 years, and mean smoking duration was 20 years in 62 current smokers. Baseline spirometric tests were significantly reduced: FVC to 95.4 mean percentage of predicted (pop), FEV1 to 94.5 pop, FEF25-75 to 85.9 pop, and FEFR75-85 to 74.8 pop. Current smokers had greater reductions in flow rates and FVC than nonsmokers even after adjustment of their predicted values for the effects of duration of smoking. Neither alveolar volume at 104.3 pop nor diffusing capacity for carbon monoxide (single breath) at 98.5 pop was reduced. There were no significant changes in pulmonary function measurements across a Monday workshift in 31 welders, but in seven men who welded stainless steel, levels of serum chromium (Cr) rose 66% from 1.9 +/- 2.1 micrograms/liter and urinary Cr increased 22%. Serum nickel levels rose only 7%, although they were elevated before shift, 1.1 +/- 0.4 micrograms/liter (compared with 0.21 +/- 0.20 micrograms/liter in controls), and urinary nickel levels did not increase. Eleven years of welding had reduced vital capacities and expiratory flows. Monday stainless-steel welding raised the serum and urine chromium levels (measures of internal dosimetry for exposure) but did not decrease pulmonary function values.

Adult↗

Short-term respiratory function changes in relation to workshift welding fume exposures.

The forced vital capacity (FVC), the forced expiratory volume in one second (FEV1) and the transfer factor for the lung (TL) were measured before and after the 8-h work shift in groups of welders and non-welder controls in a shipyard. For each subject, full-shift average concentrations of welding fume constituents were evaluated. On the average, the lung function indices in both groups of welders and controls decreased from morning through afternoon. The welders demonstrated more reduction in the indices than the control group. In general, there was no significant association between the acute changes in the lung function and the daily amount of exposure to welding fume constituents or the welding environmental factors. However, the overall difference of mean diurnal variations in TL between the groups working under different ventilation condition was significant (P < 0.01). On the average, welders who did not use any ventilation system showed maximum reduction in TL value. Acute reduction of FEV1 was positively correlated (P < 0.05) with the levels of iron oxide produced during welding.

Adult↗

Assessment of biological chromium among stainless steel and mild steel welders in relation to welding processes.

Air and biological monitoring were used for assessing external and internal chromium exposure among 116 stainless steel welders (SS welders) using manual metal arc (MMA), metal inert gas (MIG) and tungsten inert gas (TIG) welding processes (MMA: n = 57; MIG: n = 37; TIG: n = 22) and 30 mild steel welders (MS welders) using MMA and MIG welding processes (MMA: n = 14; MIG: n = 16). The levels of atmospheric total chromium were evaluated after personal air monitoring. The mean values for the different groups of SS welders were 201 micrograms/m3 (MMA) and 185 micrograms/m3 (MIG), 52 micrograms/m3 (TIG) and for MS welders 8.1 micrograms/m3 (MMA) and 7.3 micrograms/m3 (MIG). The curve of cumulative frequency distribution from biological monitoring among SS welders showed chromium geometric mean concentrations in whole blood of 3.6 micrograms/l (95th percentile = 19.9), in plasma of 3.3 micrograms/l (95th percentile = 21.0) and in urine samples of 6.2 micrograms/l (95th percentile = 58.0). Among MS welders, mean values in whole blood and plasma were rather more scattered (1.8 micrograms/l, 95th percentile = 9.3 and 1.3 micrograms/l, 95th percentile = 8.4, respectively) and in urine the value was 2.4 micrograms/l (95th percentile = 13.3). The analysis of variance of chromium concentrations in plasma previously showed a metal effect (F = 29.7, P < 0.001), a process effect (F = 22.2, P < 0.0001) but no metal-process interaction (F = 1.3, P = 0.25). Concerning urinary chromium concentration, the analysis of variance also showed a metal effect (F = 30, P < 0.0001), a process effect (F = 72, P < 0.0001) as well as a metal-process interaction (F = 13.2, P = 0.0004). Throughout the study we noted any significant differences between smokers and non-smokers among welders. Taking in account the relationships between chromium concentrations in whole, plasma or urine and the different welding process. MMA-SS is definitely different from other processes because the biological values are clearly higher. These higher levels are due to the very significant concentrations of total soluble chromium, mainly hexavalent chromium, in welding fumes.

Adult↗

Evidence for the presence of mutagenic compounds other than chromium in particles from mild steel welding.

A modified Salmonella/microsome liquid culture assay was used to investigate the mutagenicity of the particulate fraction from mild steel welding. Previous reports have implicated compounds of chromium VI as the mutagenic and toxic agents in welding fumes, since only the particles from welding on stainless steel, which contains 15-25% chromium, were mutagenic, whereas particles from welding on mild steel, which contain less than 0.1% chromium, were not mutagenic or toxic. In this investigation, mild steel particles were shown to contain direct-acting and promutagenic compounds that induced frameshift mutations. The mutagenic agents, which were insoluble in sodium phosphate buffer, did not include chromium VI or organic compounds. Further, the expression of mutation appears to require a cell-particle interaction for the release of the mutagenic species from the particles.

Aerobiosis↗

Alteration of serum concentrations of manganese, iron, ferritin, and transferrin receptor following exposure to welding fumes among career welders.

This study was performed to determine airborne manganese levels during welding practice and to establish the relationship between long-term, low-level exposure to manganese and altered serum concentrations of manganese, iron, and proteins associated with iron metabolism in career welders. Ninety-seven welders (average age of 36 years) who have engaged in electric arc weld in a vehicle manufacturer were recruited as the exposed group. Welders worked 7-8h per day with employment duration of 1-33 years. Control subjects consisted of 91 employees (average age of 35 years) in the same factory but not in the welding profession. Ambient manganese levels in welders' breathing zone were the highest inside the vehicle (1.5 +/- 0.7 mg/m3), and the lowest in the center of the workshop (0.2 +/- 0.05 mg/m3). Since the filter size was 0.8 microm, it is possible that these values may be likely an underestimation of the true manganese levels. Serum levels of manganese and iron in welders were about three-fold (p < 0.01) and 1.2-fold (p < 0.01), respectively, higher than those of controls. Serum concentrations of ferritin and transferrin were increased among welders, while serum transferrin receptor levels were significantly decreased in comparison to controls. Linear regression analyses revealed a lack of association between serum levels of manganese and iron. However, serum concentrations of iron and ferritin were positively associated with years of welder experience (p < 0.05). Moreover, serum transferrin receptor levels were inversely associated with serum manganese concentrations (p < 0.05). These findings suggest that exposure to welding fume among welders disturbs serum homeostasis of manganese, iron, and the proteins associated with iron metabolism. Serum manganese may serve as a reasonable biomarker for assessment of recent exposure to airborne manganese.

Adult↗

Soluble transition metals cause the pro-inflammatory effects of welding fumes in vitro.

Epidemiological studies have consistently reported a higher incidence of respiratory illnesses such as bronchitis, metal fume fever (MFF), and chronic pneumonitis among welders exposed to high concentrations of metal-enriched welding fumes. Here, we studied the molecular toxicology of three different metal-rich welding fumes: NIMROD 182, NIMROD c276, and COBSTEL 6. Fume toxicity in vitro was determined by exposing human type II alveolar epithelial cell line (A549) to whole welding fume, a soluble extract of fume or the "washed" particulate. All whole fumes were significantly toxic to A549 cells at doses >63 microg ml(-1) (TD 50; 42, 25, and 12 microg ml(-1), respectively). NIMROD c276 and COBSTEL 6 fumes increased levels of IL-8 mRNA and protein at 6 h and protein at 24 h, as did the soluble fraction alone, whereas metal chelation of the soluble fraction using chelex beads attenuated the effect. The soluble fraction of all three fumes caused a rapid depletion in intracellular glutathione following 2-h exposure with a rebound increase by 24 h. In addition, both nickel based fumes, NIMROD 182 and NIMROD c276, induced significant reactive oxygen species (ROS) production in A549 cells after 2 h as determined by DCFH fluorescence. ICP analysis confirmed that transition metal concentrations were similar in the whole and soluble fractions of each fume (dominated by Cr), but significantly less in both the washed particles and chelated fractions. These results support the hypothesis that the enhanced pro-inflammatory responses of welding fume particulates are mediated by soluble transition metal components via an oxidative stress mechanism.

Air Pollutants, Occupational↗

Suppression in lung defense responses after bacterial infection in rats pretreated with different welding fumes.

Epidemiology suggests that inhalation of welding fumes increases the susceptibility to lung infection. The effects of chemically distinct welding fumes on lung defense responses after bacterial infection were compared. Fume was collected during gas metal arc (GMA) or flux-covered manual metal arc (MMA) welding using two consumable electrodes: stainless steel (SS) or mild steel (MS). The fumes were separated into water-soluble and -insoluble fractions. The GMA-SS and GMA-MS fumes were found to be relatively insoluble, whereas the MMA-SS was highly water soluble, with the soluble fraction comprised of 87% Cr and 11% Mn. On day 0, male Sprague-Dawley rats were intratracheally instilled with saline (vehicle control) or the different welding fumes (0.1 or 2 mg/rat). At day 3, the rats were intratracheally inoculated with 5 x 10(3) Listeria monocytogenes. On days 6, 8, and 10, left lungs were removed, homogenized, cultured overnight, and colony-forming units were counted to assess pulmonary bacterial clearance. Bronchoalveolar lavage (BAL) was performed on right lungs to recover phagocytes and BAL fluid to measure the production of nitric oxide (NO) and immunomodulatory cytokines, including tumor necrosis factor-alpha (TNF-alpha), interleukin (IL)-2, IL-6, and IL-10. In contrast to the GMA-SS, GMA-MS, and saline groups, pretreatment with the highly water soluble MMA-SS fume caused significant body weight loss, extensive lung damage, and a dramatic reduction in pulmonary clearance of L. monocytogenes after infection. NO concentrations in BAL fluid and lung immunostaining of inducible NO synthase were dramatically increased in rats pretreated with MMA-SS before and after infection. MMA-SS treatment caused a significant decrease in IL-2 and significant increases in TNF-alpha, IL-6, and IL-10 after infection. In conclusion, pretreatment with MMA-SS increased production of NO and proinflammatory cytokines (TNF-alpha and IL-6) after infection, which are likely responsible for the elevation in lung inflammation and injury. In addition, MMA-SS treatment reduced IL-2 (involved in T cell proliferation) and enhanced IL-10 (involved in inhibiting macrophage function) after bacterial infection, which might result in a possible suppression in immune response and an increase in susceptibility to infection.

Air Pollutants, Occupational↗