Closing click of St Jude Medical and Duromedics Edwards bileaflet valves: complaints created by valve noise and their relation to sound pressure and hearing level.

The metallic clicking sound created by mechanical heart valve prostheses frequently bothers patients. To test whether sounds generated by different bileaflet valves correlate to complaints related to the prosthetic clicking 73 patients were investigated after valve replacement with Duromedics Edwards (DE) (n = 38) and St Jude Medical (SJM) (n = 35) valves. The patients were asked about their complaints, sound pressure levels were recorded and audiometry was performed. Sixty-five percent of patients could hear their valve, 18% had sleeping disturbances, 5% felt bothered during daytime and 12% would prefer a less noisy valve. In symptomatic patients, sound pressure levels were higher than in asymptomatic patients (valve audible 45 +/- 8 db(A) vs not audible 39.9 +/- 10 db(A) at 10 cm; P = 0.016). These differences were most apparent in the high frequency bands, corresponding to the metallic click. Symptomatic patients had better hearing and were younger than patients without complaints. Fifty-one percent could hear their valve by conduction through the body, after eliminating air conduction by the use of headsets. The DE prostheses were louder than the SJM valves in general (47.4 +/- 7 vs 39.8 +/- 5 db (A) at 10 cm; P = 0.001) and in each valve position. Patients with DE prostheses had significantly more complaints. The intensity of the closing click of mechanical valves correlates to the complaints caused by prosthetic clicking and thus sound emission should be considered when a mechanical heart valve prosthesis is selected.

Adult↗

[Long-term results of mechanical valves in aortic position and biological valves in mitral and tricuspid positions].

The long-term results of patients undergoing aortic valve replacement (AVR) with a mechanical valve (AM), mitral valve replacement with a biological valve (MB), and tricuspid valve replacement (TVR) with a biological valve (TB) operated upon from 1977 to 1988 were retrospectively analysed. A total of 899 patients received 1117 valves (381 AM, 633 TB, 103 TB) with a follow-up 3778 patient-years and 4582 valve-years. A significant incidence of thromboembolism, hemorrhage, and endocarditis was not found among AVR, MVR, TVR, or multiple valve replacement. We found a significantly decreased incidence of survival rate in multiple valve replacement compared with AVR or MVR, and a significantly increased incidence of reoperation in MB compared with AM and TB. We use AM and TB in any adult patients as a first choice. However, we prefer a mechanical valve in the mitral position except in patients over 65 years old, who have a short life expectancy, in whom anticoagulation is thought to be difficult, and who desire a biological valve.

Adolescent↗

Impact of valve surgery on 6-month mortality in adults with complicated, left-sided native valve endocarditis: a propensity analysis.

CONTEXT: Complicated, left-sided native valve endocarditis causes significant morbidity and mortality in adults. The presumed benefits of valve surgery remain unproven due to lack of randomized controlled trials. OBJECTIVE: To determine whether valve surgery is associated with reduced mortality in adults with complicated, left-sided native valve endocarditis. DESIGN AND SETTING: Retrospective, observational cohort study conducted from January 1990 to January 2000 at 7 Connecticut hospitals. Propensity analyses were used to control for bias in treatment assignment and prognostic imbalances. PATIENTS: Of the 513 adults with complicated, left-sided native valve endocarditis, 230 (45%) underwent valve surgery and 283 (55%) received medical therapy alone. MAIN OUTCOME MEASURE: All-cause mortality at 6 months after baseline. RESULTS: In the 6-month period after baseline, 131 patients (26%) died. In unadjusted analyses, valve surgery was associated with reduced mortality (16% vs 33%; hazard ratio [HR], 0.43; 95% confidence interval [CI], 0.29-0.63; P<.001). After adjustment for baseline variables associated with mortality (including hospital site, comorbidity, congestive heart failure, microbial etiology, immunocompromised state, abnormal mental status, and refractory infection), valve surgery remained associated with reduced mortality (adjusted HR, 0.35; 95% CI, 0.23-0.54; P<.02). In further analyses of 218 patients matched by propensity scores, valve surgery remained associated with reduced mortality (15% vs 28%; HR, 0.45; 95% CI, 0.23-0.86; P =.01). After additional adjustment for variables that contribute to heterogeneity and confounding within the propensity-matched group, surgical therapy remained significantly associated with a lower mortality (HR, 0.40; 95% CI, 0.18-0.91; P =.03). In this propensity-matched group, patients with moderate to severe congestive heart failure showed the greatest reduction in mortality with valve surgery (14% vs 51%; HR, 0.22; 95% CI, 0.09-0.53; P =.001). CONCLUSIONS: Valve surgery for patients with complicated, left-sided native valve endocarditis was independently associated with reduced 6-month mortality after adjustment for both baseline variables associated with the propensity to undergo valve surgery and baseline variables associated with mortality. The reduced mortality was particularly evident among patients with moderate to severe congestive heart failure.

Adult↗

Björk-Shiley convexoconcave valves: susceptibility artifacts at brain MR imaging and mechanical valve fractures.

PURPOSE: To assess the relationship between heart valve history and susceptibility artifacts at magnetic resonance (MR) imaging of the brain in patients with Björk-Shiley convexoconcave (BSCC) valves. MATERIALS AND METHODS: MR images of the brain were obtained in 58 patients with prosthetic heart valves: 20 patients had BSCC valve replacements, and 38 had other types of heart valves. Two experienced neuroradiologists determined the presence or absence of susceptibility artifacts in a consensus reading. Artifacts were defined as characteristic black spots that were visible on T2*-weighted gradient-echo MR images. The statuses of the 20 explanted BSCC valves-specifically, whether they were intact or had an outlet strut fracture (OSF) or a single-leg fracture (SLF)-had been determined earlier. Number of artifacts seen at brain MR imaging was correlated with explanted valve status, and differences were analyzed with nonparametric statistical tests. RESULTS: Significantly more patients with BSCC valves (17 [85%] of 20 patients) than patients with other types of prosthetic valves (18 [47%] of 38 patients) had susceptibility artifacts at MR imaging (P =.005). BSCC valve OSFs were associated with a significantly higher number of artifacts than were intact BSCC valves (P =.01). No significant relationship between SLF and number of artifacts was observed. CONCLUSION: Susceptibility artifacts at brain MR imaging are not restricted to patients with BSCC valves. These artifacts can be seen on images obtained in patients with various other types of fractured and intact prosthetic heart valves.

Adult↗

The Medtronic-Hall valve: a design in 1977 to improve the results of valve replacement.

The prototype Medtronic-Hall valve was developed from improvements to the Lillehei-Kaster and Björk-Shiley valves. The housing was constructed of a single piece of titanium and the disc was composed of pyrolytic carbon; both materials had shown no structural breakdown in previous clinical use. The valve was tested with pulse simulator and electromagnetic flow meter studies and yielded a high effective orifice area. Results in 110 patients were significantly better with the Medtronic-Hall valve than with either of the previous valves. In the 21-mm aortic valve the peak-peak gradient was 12 mmHg; it was 9.2 mmHg in the 23-mm, 3.8 mmHg in the 25-mm, and 2.5 mmHg in the 27-mm. Studies found 5% of forward flow regurgitation in the aortic position and more than desired regurgitation through the mitral valve. After the opening angle of the mitral valve was reduced to 70 degrees, regurgitation reached an acceptable level and the improved hemodynamics resulted in lower transvalvular gradients than in previous mechanical valves. Some patients are naturally more prone to thromboembolism regardless of valve type or anticoagulant therapy; thus the human factor plays a large role in a valve's success. More randomized studies are needed for accurate valve comparison, in addition to investigations of sewing ring factors. Nevertheless, the Medtronic-Hall valve has been used successfully for 15 years and has exhibited no housing fractures.

Actuarial Analysis↗

An in-vitro technique for assessment of thrombogenicity in mechanical prosthetic cardiac valves: evaluation with a range of valve types.

BACKGROUND AND AIM OF THE STUDY: An in-vitro technique has been developed to assess the flow-induced thrombosis of artificial heart valves, using renneted milk as a blood analog. Previous studies have demonstrated similarities between the clotting of blood and milk on both microscopic and macroscopic scales. The study aim was to further validate the milk test by comparing the locations of milk clot to those of thrombus formation on a wide selection of mechanical heart valves. METHODS: Nine different valves were tested in the aortic position of a model heart chamber in the Edinburgh milk rig. These included caged-ball valves (Starr-Edwards silastic ball with bare struts and metal ball with cloth-covered struts), tilting-disc valves (Björk-Shiley Standard, Björk-Shiley Monostrut, Medtronic-Hall, and Ultracor), and bileaflet valves (St. Jude Medical, Edwards-Duromedics, and CarboMedics). Renneted milk was pumped through the valves for 30 min at 2 l/min, 70 bpm pulsatile flow. After each run, valves were photographed for comparison with documented sites of thrombosis. RESULTS: All valves developed milk clot in specific, reproducible locations when run in the aortic position. Milk clot was found on the struts of caged-ball valves and tilting-disc valves, and around the hinge mechanism of the bileaflet valves. This compared favorably to documented cases of thrombosis in vivo. CONCLUSION: Renneted milk may be used to model flow-induced thrombus formation and to predict the thrombogenic sites of mechanical heart valves. Whilst it is not suggested that milk mimics the entire blood coagulation cascade, these results indicate that such behavior may not be necessary for predicting fluid mechanically induced clotting.

Animals↗

[Late results of aortic valve plasty (aortic leaflet slicing) simultaneously performed with mitral valve surgery].

We followed the course of 20 patients who underwent aortic valve plasty (AVP) combined with mitral valve surgery for rheumatic mild aortic valve disease in association with severe mitral valve disease. At operation, all patients underwent aortic leaflet slicing with a knife, and aortic commissurotomy were performed additionally in 10 patients. After surgery, the degree of aortic valve regurgitation and the amplitude of aortic leaflet motion were assessed chronologically, using ultrasound cardiography. One month after surgery, all but one patients showed a reduction in regurgitation to degree I or less. From the third post-operative year, however aortic valve regurgitation tended to increase again. However, the post-operative degree of regurgitation was observed not to be severer than the pre-operative degree of regurgitation, and no patients showed aggravation of aortic valve regurgitation attributable to exacerbation of mitral valve disease. We divided the patients into two groups according to improvement of aortic valve regurgitation. In the group where the degree of regurgitation returned to the pre-operative one, the degree of amplitude of leaflet motion began to reduce from the third post-operative year and was nearly equal to the pre-operative one at the fifth post-operative year. The results of this study can be summarized as follows: 1. From the third post-operative year, aortic regurgitation was aggravated and aortic valve motion amplitude decreased. 2. The number of sliced valve leaflets and incised commissures did not correlate well with the post-operative reduction in regurgitation.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Which biologic valve should we select for the 45- to 65-year-old age group requiring aortic valve replacement?

OBJECTIVE: The diversity of biologic valves available to replace the aortic valve renders selection difficult for the 45- to 65-year-old patient. To evaluate and compare the results of biologic valves in the 45- to 65-year-old patient, we reviewed our experience (1991-2004). METHODS: Three hundred thirty-two patients between 45 and 65 years old with isolated aortic valve disease had a biologic valve implanted: Freestyle valve in 140 patients, a homograft in 54 patients, a stented Mosaic or Perimount valve (stented xenograft) in 62 patients, and a Ross procedure in 76 patients. RESULTS: Perioperative mortality was comparable for all groups (Freestyle, 2.1%; homograft, 3.7%; stented xenograft, 3.2%; Ross procedure, 1.3%; P = .8). Echocardiographically determined valve performance at discharge was significantly enhanced in the Ross procedure and homograft groups (indexed effective orifice area: Freestyle, 0.9 +/- 0.3 cm 2 /m 2 ; homograft, 1.3 +/- 0.3 cm 2 /m 2 ; stented xenograft, 0.8 +/- 0.2 cm 2 /m 2 ; Ross procedure, 1.4 +/- 0.4; P < .0001; mean gradient: Freestyle, 12.0 +/- 6.6 mm Hg; homograft, 7.4 +/- 4.0 mm Hg; stented xenograft, 15.4 +/- 5.4 mm Hg; Ross procedure, 4.6 +/- 3.2 mm Hg; P < .0001). For all yearly follow-up, freedom from New York Heart Association class III or IV was comparable and greater than 95% for all groups. At 7 years, cardiac survival (homograft, 96.3% +/- 3.7%; Ross procedure, 90.6% +/- 6.3%; stented xenograft, 86.0% +/- 10.3%; Freestyle, 89.2% +/- 10.8%; P = .7) and freedom from reoperation (Ross procedure, 98.5% +/- 1.4%; homograft, 90.6% +/- 5.7%; Freestyle, 88.0% +/- 4.9%; stented xenograft, 90.0% +/- 8.0%; P = .4) were comparable. Freedoms from significant bleeding events, valve-related neurologic events, or endocarditis were comparable and greater than 95% for all groups. CONCLUSION: Type of aortic biologic valve for the 45- to 65-year-old patient does not affect midterm survival or valve-related morbidity. Thus the choice of biologic valve for the 45- to 65-year-old patient should be dictated by patient-surgeon preference, ease of implantation, and reoperation until longer comparative studies are available.

Age Factors↗

Semilunar valve switch procedure: autotransplantation of the native aortic valve to the pulmonary position in the Ross procedure.

BACKGROUND: The Ross procedure has gained wide acceptance in young patients with aortic valve disease. The durability of the pulmonary autograft in the aortic position has been proved, with up to 24 years of follow-up. The homograft pulmonary valve, however, has limited longevity. To circumvent this problem we harvested, repaired, and reimplanted the native aortic valve with intact commissures in the pulmonary position in 13 patients undergoing the Ross procedure for aortic insufficiency. METHODS: The cause of aortic insufficiency was rheumatic in 6 patients, congenital in 4, post-aortic valvotomy in 2, and bacterial endocarditis in 1. Patient age ranged from 5 to 45 years (mean, 17+/-9 years). Root replacement technique with coronary artery reimplantation was used. In the first 4 patients, the native aortic valve was sutured into the right ventricular outflow tract, and a polytetrafluorethylene patch was used to reconstruct the main pulmonary artery. In the last 9 patients, the aortic valve and polytetrafluorethylene patch were made into a conduit by another surgeon while the left-sided reconstruction was performed. RESULTS: All patients had marked reduction of left ventricular dilation and good function of the reimplanted native aortic valve, with up to 50 months of follow-up (mean, 29.9+/-14.2 months; range, 12 to 50 months). Two patients died 15 and 26 days, respectively, of a false aneurysm rupture at the distal aortic anastomosis. In the remaining 11 patients, 9 (82%) had mild or absent, and 2 (18%) had mild to moderate, neoaortic valve regurgitation. Similarly, 9 patients (82%) had mild or absent, and 2 (18%) had mild to moderate, neopulmonary valve regurgitation. Mild neopulmonary valve stenosis was present in 6 patients (54%) (mean gradient, 29+/-4 mm Hg; range, 25 to 35 mm Hg). All surviving patients are in functional New York Heart Association functional class I. CONCLUSIONS: We conclude that use of the native aortic valve with the Ross procedure makes the procedure attractive and potentially curative. The diseased aortic valve works well in the pulmonary position because of lower pressure and resistance. The valve leaflets should remain viable and grow in both the pulmonary and aortic positions because they derive nutrition directly from the blood.

Adolescent↗

Hydrodynamic function of tilting disc prostheses and bileaflet valves in double valve replacement.

OBJECTIVE: To determine the energy loss attributable to prosthetic valve size and design in double valve replacement, energy consumption of mitral valves (size #25 to #29), of two different designs (Bjork Shiley tilting disc and Carbomedics bileaflet valves), in combination with a small (#21) and large sized (#27) aortic prosthesis, were analyzed in a flow simulator. METHODS: A pulsatile flow simulator was used to reproduce physiological ventricular dynamics and to match the input and output impedances of the human left ventricle. Hydrodynamic performance was determined as stroke work, closing work and leak work for each combination of valves at low flow (5 liters per minute) and high flow (9 liters per minute) conditions. RESULTS: At low flow no decrease of energy requirement was found with the use of a mitral valve larger than #25. At high flow the #27 and #29 mitral valves required less energy compared to a #25 mitral valve, in combination with a large aortic prosthesis. The #29 mitral prosthesis revealed similar results as the #27. With the use of a large aortic prosthesis a remarkable reduction of total flow work was shown. These results were found in both designs. In comparison of the two designs, tilting disc valves required more energy for stroke and closure of the valve, although less energy for leakage. In total, energy requirements were higher for tilting disc valves. COMMENTS: A hydrodynamic advantage for the use of a mitral valve larger than #25 was found only with the combination of a large aortic prosthesis and high flow. Hydrodynamic data favor the use of bileaflet prosthesis especially for a patient who is expected to exercise.

Aortic Valve↗

Long-term results after aortic valve replacement in patients with congestive heart failure. Homografts vs prosthetic valves.

OBJECTIVES: The aim of this study was to assess the influence of valve substitute (homograft vs prosthetic valve) on the long-term survival and late valve-related complication rates following aortic valve replacement in patients with aortic valve disease and congestive heart failure. BACKGROUND: The effect of choice of valve substitute on outcome after aortic valve replacement in patients with pre-operative heart failure is unknown. The superior haemodynamic profile of homografts may be of particular benefit. METHODS: We retrospectively analysed pre-operative, operative and follow-up data on 518 adults in functional classes III and IV, who, over the 25 years 1969-1993, had their initial aortic valve replacement at Harefield hospital. Follow-up conducted during 1996 to April 1997 and totalling 4439 patient-years was 96.1% complete. Using multivariate analysis, independent risk factors for different complications and mortality were defined. RESULTS: Overall 5-, 10- and 20-year survival was 80+/-2%, 62+/-2% and 30+/-3%, respectively, with no significant difference between valve types. However, homografts (n=381) independently reduced the rate of serious complications and cardiac death, whereas mechanical valves were an independent adverse risk factor for late mortality. The rates of anticoagulant-related bleeding and thromboembolism were increased by mechanical valves, whereas primary tissue failure was the main complication of homografts. CONCLUSIONS: Long-term outcome of homograft aortic valve replacement in patients with congestive heart failure is acceptable, with a reduced rate of serious complications and cardiac death. Further improvements would be expected if the rate of primary tissue failure could be reduced.

Adolescent↗

Progression of aortic valve dysfunction in 51 adult patients with congenital bicuspid aortic valve: assessment and follow up by Doppler echocardiography.

OBJECTIVE: To assess the pattern and progression of aortic valve dysfunction by serial Doppler echocardiographic examinations in ambulatory adult patients with congenital bicuspid aortic valve. DESIGN AND SETTING: Retrospective analysis of patients referred for Doppler echocardiography over a four year period. SUBJECTS: Fifty one adult patients with echocardiographic diagnosis of congenital bicuspid aortic valve had serial Doppler echocardiographic studies at least six months apart. There were 40 men and 11 women with a mean age of 36 years. MAIN OUTCOME MEASURE: Doppler echocardiographic values of aortic valve dysfunction. Cardiac events including endocarditis and aortic valve replacement were also evaluated. RESULT: Coarctation was present in five patients. 31 (61%) patients had a functionally normal bicuspid aortic valve defined as a mean gradient < 25 mm Hg and mild regurgitation. Significant aortic regurgitation was present in 15 patients (moderate in 12 and severe in three). Three patients had isolated aortic stenosis and two patients had combined aortic valve dysfunction. At a median follow up of 21 months (range six to 46 months), six patients had aortic valve surgery (one for aortic stenosis, three for aortic regurgitation, and two for endocarditis). Only 22 patients (43%) continued to have a functionally normal aortic valve. CONCLUSION: In this cohort of fairly young patients, aortic regurgitation is more common than aortic stenosis. Progression of aortic valve dysfunction occurs in patients with pre-existing valve dysfunction and even in those with normal aortic valve function at the initial echocardiographic examination.

Adult↗

The use of a rigid instrument prior to stentless valve implantation facilitates correct alignment of the prosthesis and native aortic valve apparatus.

BACKGROUND AND AIM OF THE STUDY: When correctly seated in the aortic position, stentless valves are associated with a relatively low transvalvular gradient. This leads to regression of left ventricular hypertrophy and long-term survival. The alleged complexity of stentless valve implantation has led to a preference for stented/mechanical prostheses. Here, the use of a rigid instrument to prevent technical complications after stentless valve implantation was investigated. METHODS: Aortic valve replacement was performed in 75 patients (44 males, 31 females; mean age 72 years; range: 33-89 years) using the Toronto Stentless Porcine Valve (TSPV). Among patients, 37% had coronary artery bypass grafting and 3% mitral valve replacement. Valve size was either 23-25 mm (65%) or 21 mm (35%) and determined by sinotubular junction diameter. A rigid instrument was designed that mimics actual valve shape and accounted for valve dimensional variations and asymmetries on a size-by-size basis. The instrument was used to mark the site of the inflow and outflow suture lines and to determine orientation of the muscle bar on the prosthetic valve. Intraoperative transesophageal echocardiography was used to monitor all patients. RESULTS: The mean intraoperative mean systolic peak pressure gradient (all valves) was 18.35 +/- 9.41 mmHg; there were no paravalvular leaks. Among patients, 22% had central trace aortic insufficiency, and one patient developed renal failure that required hemodialysis. There were no cerebral vascular accidents/infections, but one perioperative myocardial infarction occurred. There were four postoperative deaths, but none was valve-related. CONCLUSION: Routine use of the instrument may avoid many risks during TSPV implantation. The device permits the surgeon to accommodate variation in the angle between the coronary ostia, as well as in the distance between these ostia and the native annulus.

Adult↗

The multifactorial etiology of mitral valve prolapse, a new entity of postinflammatory mitral valve prolapse.

As etiologic factors for mitral valve prolapse, papillary muscle dysfunction due to coronary artery disease, hypertrophic obstructive cardiomyopathy, atrial septal defect and trauma have been reported. Connective tissue diseases such as Marfan's syndrome. Ehlers-Danlos syndrome or Turner's syndrome may also result in mitral valve prolapse. In the majority of patients with mitral valve prolapse, however, the etiology is unknown, in which case the condition is considered primary or idiopathic. We evaluated 33 consecutive surgically-excised mitral valves removed from patients with regurgitant prolapsing mitral valves and congestive heart failure. On microscopic examination, myxomatous degeneration was observed in 14 cases, postinflammatory changes, however, were seen in the other 19 cases and included diffuse vascularization with thick-walled vessels, round-cell infiltration and destruction of valve architecture. These valves showed a varying degree of doming and/or interchordal hooding as well as an increased surface area. Elongated chordae tendineae were seen in 37%, chordal rupture in 16% of the patients. Slightly fused chordae tendineae, minimal commissural fusion and/or fibrous thickening of cusps were also observed, findings which simulate closely rheumatic valvulitis. Patients with postinflammatory mitral valve prolapse were younger at the time of operation and at the onset of symptoms, had smaller surface areas of the anterior mitral leaflet and more marked leaflet thickening than patients with myxomatous mitral valve prolapse. The results of the study show that mitral valve prolapse in patients with severe mitral regurgitation can be attributed to postinflammatory changes; we suggest, therefore, the term "postinflammatory valve prolapse". Postinflammatory mitral valve prolapse may be due to manifest or subclinical rheumatic fever.(ABSTRACT TRUNCATED AT 250 WORDS)

Chordae Tendineae↗

Aortic valve replacement with stentless porcine aortic valves: a ten-year experience.

BACKGROUND AND AIMS OF THE STUDY: It has been shown that although stentless porcine aortic valves have better hemodynamic features than stented porcine valves, their long-term durability remains unknown. This study was undertaken to examine the long-term clinical outcome of aortic valve replacement (AVR) with stentless porcine aortic valves. METHODS: Between 1987 and 1989, custom-made stentless valves were implanted in 29 patients (mean age 58 years), and between 1991 and 1997, the Toronto SPV was implanted in 213 patients (mean age 63 years). In addition to AVR, one-third of the patients had coronary artery bypass. All patients were followed up at annual intervals and underwent Doppler echocardiography. RESULTS: There were two operative and 11 late deaths (four cardiac, seven non-cardiac). The actuarial survival rate was 89 +/- 4% at nine years. There were two strokes and seven transient ischemic attacks; freedom from thromboembolic complications was 92 +/- 4% at nine years. Two patients developed infective endocarditis, one early and one late; freedom from prosthetic valve endocarditis was 98 +/- 1% at nine years. Freedom from primary tissue failure was 85 +/- 8% at nine years. Seven patients required repeat AVR, because of endocarditis (two) and aortic insufficiency (five); freedom from repeat AVR was 82 +/- 8% at nine years. Periodic hemodynamic assessment by echocardiography indicated that the mean systolic gradients across the valve decreased during the first year of implantation, the valve effective orifice increased, and valve competence remained stable. CONCLUSIONS: Stentless porcine aortic valves have provided excellent clinical results. These valves may suffer degenerative changes and fail at the same rate as stented porcine aortic valves but, because of their superior hemodynamic performance, they may enhance patients' survival by allowing complete regression of left ventricular hypertrophy and restoration of normal ventricular function.

Animals↗

Mitral valve replacement using bileaflet mechanical prosthetic valve in the first year of life.

OBJECTIVE: The operative management and long term outcome of mitral valve replacement in infancy remain a therapeutic challenge. The selection of a prosthetic valve for this particular age group might affect the clinical outcome. Here we present our experience of mitral valve replacement in 6 infants using small bileaflet mechanical prosthetic valves. METHODS: Between January 1994 and August 1997, 6 infants (their age ranged from 3 months to 11 months, and their body weight from 2978 g to 7403 g) underwent mitral valve replacement using a mechanical valve prosthesis (16 mm CarboMedics prosthetic valve in 5, and 17 mm St. Jude Medical prosthetic valve Hemodynamic Plus in 1). The preoperative morphological features of the mitral valve were stenosis in 1, regurgitation in 3, and a combination of these in 2. The prosthesis was fixed at the annulus in 3, and at the supra-annular position in 3. Anticoagulation was performed using warfarin. RESULTS: There was no operative mortality. Postoperative catheterization revealed an acceptable wedge pressure in the pulmonary arteries, ranging from 10 to 12 mmHg. During the mean follow-up period of 36 months, late death due to residual pulmonary hypertension occurred in 1 patient at 10 months after surgery. Excluding this patient, all remaining patients are doing well with no need for repeated operation with no thromboembolic complication. The actuarial survival rate and the reoperation free rate at 70 months are 83 +/- 15% and 100%, respectively. CONCLUSION: Mitral valve replacement using a small size bileaflet mechanical prosthetic valves in infancy can be performed with low operative mortality and with satisfactory mid-term results.

Follow-Up Studies↗

The coupling valve graft: a procedure for double-valve replacement.

Coupling valve grafting, a procedure to enlarge the annulus of the aortic valve and of the mitral valve simultaneously, is described. It consists of extending the J-shaped aortotomy through the middle of the noncoronary cusp into the superior aspect of the left atrium and down the anterior leaflet of the mitral valve. Then the mitral and aortic valves are replaced with a coupling valve graft, a vascular prosthesis attached to two prosthetic valves. This technique seems to be most suitable for patients in whom the valves of both annuli are narrow, as is often seen in aortic and mitral stenosis. Since both valve annuli can be enlarged greatly in this procedure, combinations of prosthetic valve sizes can be freely chosen for the two valves.

Adult↗

The importance of valve alignment in determining the pressure/flow characteristics of differential pressure shunt valves with anti-gravity devices.

OBJECT: The proper functioning of shunt valves in vivo is dependent on many factors, including the valve itself, the anti-siphon device or ASD (if included), patency of inlet and outlet tubing, and location of the valve. One important, but sometimes overlooked, consideration in valve function is the valve location relative to the tip of the ventricular inlet catheter. As with any pressure measurement, the zero or reference position is an important concept. In the case of shunt valves, the position of the proximal inlet catheter tip is fixed and therefore serves as the reference point for all pressure measurements. This study was conducted to document the importance of this relationship for the pressure/flow characteristics of the shunt valve. METHODS: We bench-tested differential pressure valves (with integral anti-gravity devices; AGDs) from three manufacturers. Valves were connected to an "infinite" reservoir, and the starting head pressure for each was determined from product inserts. The inlet catheter tip was fixed at this position, and the valve body was moved in relation to the inlet catheter tip. Outflow rates were determined gravimetrically for positions varying between 4 cm above and 8 cm below the inlet catheter tip. CONCLUSIONS: All differential pressure valves utilized in this study that contained AGDs showed significant increases in outflow rate as the valve body was moved incrementally below the level of the inlet catheter tip. To allow functioning as a zero-hydrostatic pressure differential pressure valve, the AGD and the inlet catheter tip should be aligned at the same horizontal level.

Cerebrospinal Fluid Pressure↗