Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Titanium”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14Linked to original sources

[Studies on application of pure titanium for cast plate].

Pure titanium produced by a commercial pure titanium casting system was studied for use as a cast plate for clinical application. The mechanical properties, elemental analysis, castability, adaptability of pure titanium and adhesion to denture base resin were investigated. The interfacial zone of the pure titanium castings was composed of a layered structure obtained by reaction with phosphate bonded Al2O3/SiO2 investment material. Vicher's hardness at 100 microns thick from the surface was higher than that in the inner part by oxidation. Cast pure titanium showed tensile strength, elongation and hardness close to those of the type III or IV dental gold alloy. The castability of pure titanium was lower than that of Co-Cr alloy and pure titanium castings also had large casting defects. Adaptability between pure titanium cast plate and the working model was satisfactory when reversible hydrocolloid impression material was used with heating-bath treatment in the refractory model. The tensile and compressive shear bonding strength of pure titanium to heat-curing or self-curing resin were similar to that of the Co-Cr alloy, and surface treatment using a solution containing 2-vol% 3-methacryloxypropyltrimethoxysilane produced a higher bonding strength than non-treatment, MKV treatment and 4-META treatment. These findings suggest that pure titanium castings produced by this system have suitable mechanical properties, adaptability and adhesion to denture base resin, and is available for cast plate in clinical application.

Adhesiveness↗

Experimental salivary pellicles formed on titanium surfaces mediate adhesion of streptococci.

The goal of this study was to characterize salivary components of titanium pellicles and to determine how experimental pellicles affect adhesion of several strains of streptococci to titanium surfaces. Titanium experimental pellicles were formed by incubation of fresh human parotid or human submandibular-sublingual saliva on pure titanium beads. Pellicle was recovered from the beads using sodium dodecyl sulfate buffer and was subjected to sodium dodecyl sulfate-polyacrylamide gel electrophoresis and Western blotting to identify adsorbed salivary components. Streptococcus anginosus, S. oralis, and S. salivarius recovered from in vivo titanium plaque and five reference strains of streptococci were used in adhesion assays to titanium beads with and without experimental salivary pellicles. The experimental pellicle formed on titanium was found to be composed of selected proteins from human parotid and human submandibular-sublingual saliva. Salivary alpha-amylase and proline-rich proteins were found in all experimental pellicles, while sIgA, high-molecular weight mucin, and proline-rich glycoproteins were detected in one of the experimental pellicles examined. Adhesion of fresh isolates and reference stains of S. anginosus, S. oralis, and S. salivarius to saliva-coated titanium was reduced compared to that of titanium without saliva coating. However, adhesion of laboratory strains of S. gordonii and S. sanguis was found to be significantly greater to experimental pellicles of human submandibular-sublingual saliva than was the adhesion of the fresh isolates, suggesting that streptococci-colonizing implant surfaces may be inherently less adhesive than other bacterial strains. This study found that salivary pellicles are selectively formed on titanium and mediate in vitro adhesion of streptococci.

Adsorption↗

Effects of serum protein opsonization on cytokine release by titanium-alloy particles.

This study tested whether macrophages respond differently to retrieved titanium-alloy particles than they do to machined titanium-alloy particles and assessed whether pretreatment of machined titanium-alloy particles with human serum would influence macrophage activation and cytokine release in vitro. Human monocyte/macrophages were isolated from normal healthy donors and exposed to increasing concentrations of machined and retrieved titanium-alloy particles. The profile of cytokine release was determined by commercially available ELISA kits. Machined titanium-alloy particles were opsonized with human serum and added to macrophage cultures. Serum protein binding was confirmed by SDS-PAGE analysis. The results showed that machined titanium-alloy particles and retrieved titanium-alloy particles stimulate a similar level of cytokine release when tested at comparable concentrations. Opsonization of the machined particles with human serum increased the macrophage release of cytokines in the first 12 h after exposure compared to nonopsonized particles. At 24 h, the opsonized particles stimulated significantly higher levels of cytokine release, but only at the greatest particle concentrations. This study demonstrates that machined titanium alloy induces a metabolic response in macrophages similar to that of titanium-alloy particles retrieved from failed total hip arthroplasty. In addition, these data show that serum protein binding to orthopedic biomaterial debris alters the macrophage reaction to the particles.

Alloys↗

Effect of anti-inflammatory medication on monocyte response to titanium particles.

Cytokines produced by macrophages in the periprosthetic membranes surrounding joint replacements have been implicated as causal agents in osteolysis and prosthetic loosening. The present study characterizes the response of human peripheral blood monocytes to titanium particles. Monocytes were obtained from donated blood and were cultured in the presence of different-sized titanium particles. Exposure to titanium-aluminum-vanadium particles significantly changed the release of tumor necrosis factor-alpha (TNF-alpha), interleukin-6 (IL-6), and interleukin-1 (IL-1), whereas there was no significant effect on the release of prostaglandin E(2) (PGE(2)). When monocytes were cultured with particles, the titanium alloy particles induced significantly more release of TNF-alpha and less IL-1 secretion. Ciprofloxacin inhibited production of TNF-alpha, IL-6, IL-1, and PGE(2) in human monocytes exposed to titanium particles. In contrast to ciprofloxacin, indomethacin was not a potent inhibitor of TNF-alpha production but potentiated IL-6 production in titanium-stimulated monocytes. Indomethacin had no effect on the production of IL-1 and was a potent inhibitor of PGE(2) production in titanium-stimulated monocytes. Pentoxifylline had an inhibitor effect on TNF-alpha production in titanium-stimulated monocytes. Pentoxifylline potentiated IL-6 and IL-1 production in monocytes exposed to titanium particles and had a biphasic effect on the PGE(2) production. The results of this study support our hypothesis that human monocytes release bone resorption mediators after in vitro exposure to TiAlV alloy particles. The results also demonstrate the differences of bone-resorbing mediators in response to different wear particle size. The pharmacologic agents (ciprofloxacin, pentoxifylline, and indomethacin) that can modulate the release of bone resorbing mediators such as PGE(2), TNF-alpha, IL-1, and IL-6 release from human monocytes. The results help to elucidate the differences in cellular response to wear particles but may not be directly transposed to the human situation.

Anti-Infective Agents↗

Osteoblast culture on polished titanium disks modified with phosphonic acids.

Titanium is widely used in dental implants due to its suitable physical properties and its good biocompatibility. However, it is integrated into bone only passively, and the resulting fixation in the bone, which is necessary for the function, is mainly mechanical in nature. With the objective of increasing the chemical interaction between the implant and the bone tissue, several phosphonic acids were synthesized and grafted onto titanium disks. Here we report on the proliferation, differentiation, and protein production of rat osteoblastic cells (CRP10/30) on phosphonic-acid-modified titanium surfaces studied in vitro. No statistical differences were found in osteoblast proliferation among the phosphonic-acid-modified titanium, unmodified titanium, and tissue culture plastic (used as a positive control), indicating that the phosphonic acids used were not cytotoxic to the osteoblasts used. For all surfaces (modified or not), the alkaline phosphatase activity was at least as good as it was on tissue culture plastic. However, the total amount of protein, and especially the collagen type I synthesis, was sensitive to surface modification. On titanium modified with ethane-1,1,2-triphosphonic acid, the total amount of synthesized protein was significantly higher than it was on unmodified titanium surfaces. A significant increase (up to 16%) of collagen type I production was observed on titanium surfaces modified with this acid or with methylenediphosphonic acid compared to unmodified titanium surfaces.

Alkaline Phosphatase↗

Enhancement of bone growth in titanium fiber mesh by surface modification with hydrogen peroxide solution containing tantalum chloride.

A tight fixation between bone and implant materials is of great importance for a successful outcome of procedures such as total knee arthroplasty (TKA) and total hip arthroplasty (THA). Surface modification of titanium metal and titanium alloy is one of the attractive methods to improve the biological affinity of orthopedic prostheses. Recent studies reported that titanium substrates were provided with bone-bonding ability, that is, osteoconductivity, through a chemical treatment with hydrogen peroxide solution containing tantalum chloride. The present study investigated the histological and mechanical effects of such treatment of the surface of titanium fiber mesh. Titanium alloy rods of 7.6 x 7.6 x 20 mm that had a titanium fiber mesh of 250 microm were implanted bilaterally into the distal aspect of the femur of adult beagle dogs. At 3, 5, and 8 weeks after implantation, the rods were removed to examine their bonding strength and histological compatibility with bone. Bonding strength was evaluated by the pull-out test. The bonding strength of the treated specimen with bone increased with time, and was faster than that of untreated specimens. At 8 weeks postoperative, the bonding strength of both the treated and untreated specimens became almost equal. The amount of newly formed bone on and in the titanium fiber mesh was significantly increased by the chemical treatment (p<0.05). The rate of bone formation in the fiber mesh was accelerated after chemical treatment. These results indicated that the surface treatment enhanced bone formation in the initial stage thank to the osteoconductive property of the titanium fiber mesh conferred by the chemical treatment so that faster bonding strength was achieved. Surface treatment providing titanium mesh with osteoconductivity has the advantages of the fast healing and tight bonding for prostheses in TKA and THA.

Animals↗

Effects of sandblasting and electrical discharge machining on porcelain adherence to cast and machined commercially pure titanium.

The aim of this study was to determine the effect of sandblasting and electrical discharge machining (EDM) on cast and machined titanium surfaces and titanium-porcelain adhesion. Twenty machined titanium specimens were prepared by manufacturer (groups 1 and 2). Thirty specimens were prepared with autopolymerizing acrylic resin. Twenty of these specimens (groups 3 and 4) were cast with commercially pure titanium and the alpha-case layer was removed. For control group (group 5), 10 specimens were cast by using NiCr alloy. Groups 2 and 4 were subjected to EDM while groups 1, 3, and 5 were subjected to sandblasting. Surface examinations were made by using a scanning electron microscope (SEM). A low-fusing porcelain was fused on the titanium surfaces, whereas NiCr specimens were covered using a conventional porcelain. Titanium-porcelain adhesion was characterized by a 3-point bending test. Results were analyzed by Kruskal-Wallis and Mann-Whitney U tests. Metal-porcelain interfaces were characterized by SEM. The bond strength of control group was higher than that of the titanium-porcelain system. There was no significant difference between cast and machined titanium groups (p > 0.05). There was no significant difference between EDM and sandblasting processes (p > 0.05). The use of EDM as surface treatment did not improve titanium-porcelain adhesion compared with sandblasting.

Acrylic Resins↗

Effect of surface reaction layer on grindability of cast titanium alloys.

OBJECTIVE: The purpose of this study was to investigate the effect of the cast surface reaction layer on the grindability of titanium alloys, including free-machining titanium alloy (DT2F), and to compare the results with the grindability of two dental casting alloys (gold and Co-Cr). METHODS: All titanium specimens (pure Ti, Ti-6Al-4V and DT2F) were cast using a centrifugal casting machine in magnesia-based investment molds. Two specimen sizes were used to cast the titanium metals so that the larger castings would be the same size as the smaller gold and Co-Cr alloy specimens after removal of the surface reaction layer (alpha-case). Grindability was measured as volume loss ground from a specimen for 1 min using a handpiece engine with a SiC abrasive wheel at 0.1 kgf and four circumferential wheel speeds. RESULTS: For the titanium and gold alloys, grindability increased as the rotational speed increased. There was no statistical difference (p>0.05) in grindability for all titanium specimens either with or without the alpha-case. Of the titanium metals tested, Ti-6 Al-4V had the greatest grindability at higher speeds, followed by DT2F and CP Ti. The grindability of the gold alloy was similar to that of Ti-6 Al-4V, whereas the Co-Cr alloy had the lowest grindability. SIGNIFICANCE: The results of this study indicated that the alpha-case did not significantly affect the grindability of the titanium alloys. The free-machining titanium alloy had improved grindability compared to CP Ti.

Alloys↗

Sun protection enhancement of titanium dioxide crystals by the use of carnauba wax nanoparticles: the synergistic interaction between organic and inorganic sunscreens at nanoscale.

Carnauba wax is partially composed of cinnamates. The rational combination of cinnamates and titanium dioxide has shown a synergistic effect to improve the sun protection factor (SPF) of cosmetic preparations. However, the mechanism of this interaction has not been fully understood. In this study, an ethanolic extract of the carnauba wax and an ethanolic solution of a typical cinnamate derivative, ethylcinnamate, were prepared and their UV absorption and SPF either alone or in the presence of titanium dioxide were compared. The titanium dioxide crystals and the cinnamates solutions were also distributed into a matrix composed of saturated fatty acids to emulate the structure of the crystallized carnauba wax. SPF, differential scanning calorimetry (DSC) and X-ray studies of these matrices were performed. Additionally, carnauba wax nanosuspensions containing titanium dioxide either in the lipid phase or in the aqueous phase were prepared to evaluate their SPFs and their physical structure. Strong UV absorption was observed in diluted suspensions of titanium dioxide after the addition of cinnamates. The saturated fatty acid matrices probably favored the adsorption of the cinnamates at the surface of titanium dioxide crystals, which was reflected by an increase in the SPF. No modification of the crystal structure of the fatty acid matrices was observed after the addition of cinnamates or titanium dioxide. The distribution of the titanium dioxide inside the lipid phase of the nanosuspensions was more effective to reach higher SPFs than that at the aqueous phase. The close contact between the carnauba wax and the titanium dioxide crystals after the high-pressure homogenization process was confirmed by transmission electron microscopy (TEM).

Calorimetry, Differential Scanning↗

Accidental releases of titanium tetrachloride (TiCl4) in the context of major hazards--spill behaviour using REACTPOOL.

Titanium tetrachloride is a highly toxic and corrosive substance that is used widely in the process industries. On accidental release, it creates liquid pools that can either boil or evaporate. The main feature of the liquid pool is the reaction of titanium tetrachloride with water. There are three sources of water available for reaction: free ground water, atmospheric moisture and substrate water. Unfortunately, there is no specific study that examines the liquid phase hydrolysis reaction of titanium tetrachloride. Based on thermodynamic calculations and relevant information found on the topic, it is concluded that liquid titanium tetrachloride reacts exothermically with all three sources of water yielding hydrogen chloride gas and a solid complex of titanium oxychloride. The purpose of this paper is to describe the spill behaviour of titanium tetrachloride reporting a number of results using the REACTPOOL model [T. Kapias, R.F. Griffiths, C. Stefanidis, REACTPOOL: a code implementing a new multi-compound pool model that accounts for chemical reactions and changing composition for spills of water reactive chemicals, J. Hazard. Mater. A81 (2001) 1-18]. It also addresses the dangers involved in cases of accidental release of titanium tetrachloride and reports its properties, referring to toxicity data and other relevant information. The spill behaviour of titanium tetrachloride has been incorporated into REACTPOOL. Model results indicate that the pool behaviour is mainly affected by the amount of free ground water, the wind speed and surface roughness. Although titanium tetrachloride has been involved in a number of major accidents, there are no experimental data relevant to the modelling requirements.

Accidents, Occupational↗

Strength of porcelain fused to titanium beams.

The purposes of this study were to measure strengths of layered porcelain fused to titanium beams, determine failure modes, and investigate the porcelain-titanium interface. A three-point flexural test and formulas derived especially for this purpose were used. The strength of layered porcelain-ceramic beams was limited by the cohesive tensile or compressive strengths of the porcelain, not by the porcelain-titanium interfacial bond, namely, the porcelain failure occurred at lower loads than did failure of the porcelain-titanium interface. The porcelain-titanium bond strength was at least 26 MPa. Scanning electron microscopy and energy-dispersive x-ray spectroscopy demonstrated that the bond was limited by delamination of a thin titanium-titanium oxide interface. Theoretic curves that describe effects of relative layer and total thickness on the force-bearing capacity of model beams were plotted. These curves indicated that porcelain-titanium prostheses should be made as thick as is practical, but the relative thickness of the porcelain and titanium layers would be less important.

Analysis of Variance↗

The corrosion resistance of pure titanium in organic acids.

The purpose of this study was to assess the corrosive properties of titanium at various pH values. Cast pure titanium specimens were immersed in 128 mmol/l of lactic and formic acids at pH 1.0-8.5 for 3 weeks at 37 degrees C. The solubility, color, weight and chemical binding state of specimens were observed. Titanium dissolved in all lactic acid. The amount of dissolved titanium tended to decrease with a higher pH. In formic acid, the amount of dissolved titanium at pH 1.0 was larger than that in lactic acid at the same pH, but less than the detectable limit at pH 4.0 or higher. Significant discoloration was macroscopically observed only in formic acid at pH 2.5 and 4.0. The weight of the titanium samples immersed in lactic acid all decreased, but it was not affected by pH. In formic acid, the weight decreased at pH 1.0 and increased at pH 2.5-5.5. Thickening of the TiO2 corresponding to that showing discoloration was observed in the superficial oxide film of the titanium samples. Our results show that the corrosive properties of titanium are markedly dependent on pH in formic acid, and relatively less dependent on pH in lactic acid in which titanium is dissolvable at pH 1.0-8.5.

Binding Sites↗

Adsorption and dissolution behavior of human plasma fibronectin on thermally and chemically modified titanium dioxide particles.

Titanium is known for its biocompatibility and is widely used in dental and orthopedic reconstructive surgery. There are reports that osteointegration of these implants is not optimal. The objective of this study was to modify titanium dioxide particles and examine the resultant effects on protein adsorption to these altered surfaces using a model cell binding protein, human plasma fibronectin (HPF). HPF is an important matrix glycoprotein that plays a major role in cell and protein attachment, Titanium dioxide surfaces were modified by heating the titanium dioxide powder at 800 degrees C for 1 h or treating with an oxidizing agent: peroxide in ammonium hydroxide followed by peroxide in hydrochloric acid. Oxidized and control samples were further treated with 9:1 butanol:water for 30 min. Brunauer-Emmett-Teller showed no change in particle surface area as a result of thermal or chemical treatment. Hydrophobicity increased with butanol treatment of titanium dioxide. Diffuse reflectance Fourier transform infrared spectroscopy showed the presence of -CH2 and -CH3 vibrations in the region of 2850-3000 cm(-1) for both the heated, butanol and peroxide/butanol-treated samples. The absence of increased C-O and O-C=O features as determined by electron spectroscopy for chemical analysis indicates that butanol adsorption is not occurring via an esterification mechanism. The interaction between butanol and pre-heated or peroxide-treated titanium dioxide may be one of association (weak electrostatic and/or Van der Waals forces) rather than direct ionic bonding. Maximum HPF adsorption on modified or unmodified titanium dioxide occurred within 30 min, with greater protein adsorption occurring on butanol-treated samples. Desorption was minimal with all modifications. Zeta potential measurements showed that HPF adsorption caused an increase in the negative zeta potential with the greatest change noted for the butanol-treated samples. These findings suggest that wettability and surface charge both play an important role in protein adsorption to titanium dioxide. Thus, by modifying the physico-chemical properties of titanium dioxide surfaces, it may be possible to alter protein adsorption and hence optimize cell attachment.

1-Butanol↗

Diverse mechanisms of osteoblast spreading on hydroxyapatite and titanium.

Hydroxyapatite (HA) is an osteoconductive implant material. We previously demonstrated that RGD peptides regulate the spreading of HOS cells on HA but not on titanium, speculating that the osteoconductivity of HA might be attributed to this RGD domain-dependent spreading of osteoblasts. To confirm this hypothesis, the molecules which regulate the spreading of HOS cells on HA and on titanium were investigated. The 50% effective dose (ED50) of RGD peptide for the spreading on HA was five fold lower comparing to titanium. Anti-alphaV integrin antibody, vitronectin, and fibronectin inhibited the spreading on HA but not on titanium. In Western blot analysis, vitronectin and fibronectin were found in components adsorbed to HA but not to titanium. Taken together, the spreading of HOS cells on HA but not on titanium requires the interaction of alphaV integrin and its ligands. The ED50 of the RGD peptides on titanium but not on HA was remarkably reduced by neuraminidase treatment, that by itself could not inhibit the spreading on both materials. This phenomenon suggests that RGD domain and sialic acid cooperatively but not independently mediate the spreading of HOS cells on titanium. Collectively, the molecules regulating the spreading on HA are apparently different from those on titanium. The spreading of osteoblasts mediated by RGD domain of vitronectin and fibronectin might contribute to the osteoconductive ability of HA.

Biocompatible Materials↗

Plaque, gingival health and post-operative sensitivity in titanium inlays and onlays: a randomized controlled clinical trial.

OBJECTIVES: Few clinical data on the use of titanium for restorative appliances are available. The aim of this study was to clinically evaluate titanium restorations compared to gold alloy restorations with regard to plaque, gingival health and post-operative sensitivity. METHODS: In 54 patients, 99 titanium restorations were placed. The control group comprised 56 patients with 96 high gold alloy restorations. The material was chosen by random. Each patient received one or two Class II restorations. Plaque Index (Silness and Löe, 0-3), Gingival Index (Löe and Silness, 0-3), and post-operative sensitivity (1-4, 1=none) were rated at 2 weeks, 3 months, 6 months, 12 months, and 18 months, post-operatively. RESULTS: The mean plaque scores ranged from 0.89 to 0.99 in the titanium group, and from 0.88 to 1.04 in the gold group. The mean gingival scores ranged from 0.91 to 1.07 in the titanium group, and from 0.82 to 0.99 in the gold group. The mean plaque and gingival scores of the titanium and gold group did not differ significantly at any visit (P>0.05). To evaluate post-operative sensitivity, patients with one MOD restoration each were included, resulting in 46 titanium and 44 high gold restored teeth. Mean values of the post-operative sensitivity scores in the titanium group were significantly higher than in the gold group (P<0.05). The restoration material was found to be the dominating variable with regard to post-operative sensitivity, which was not influenced by age, sex and the application of calcium hydroxide liner. CONCLUSIONS: It is concluded that neither higher plaque scores nor adverse effects on gingival health are to be expected in titanium restorations.

Adolescent↗

Cytokine response of human macrophage-like cells after contact with polyethylene and pure titanium particles.

The aim of this study was to establish a human macrophage cell culture system to examine the effect of polyethylene (PE) and titanium particles on cytokine release by macrophage-like cells (MLC) and to quantify this response with respect to the nature and concentration of particles. Human monocytic leukemia cells were differentiated under standard conditions with vitamin D3 and granulocyte macrophage-colony-stimulating factor. Cells were characterized by fluorescence-activated cell-sorter Scan of CD 14 expression analysis as well as a phagocytosis test exploiting fluorescence-labeled particles of bacteria] walls. To achieve a relevant contact between the floating PE particles (approximately 1 microm in size) and MLC, a rotation device was used (15 rotations/min) during incubation. The same was done with the titanium particles. Cell culture supernatants were then analyzed for interleukin (IL)-1beta, IL-8, and tumor necrosis factor (TNF)-alpha using the enzyme-linked immunosorbent assay technique in the absence or presence of particles. Rotation of incubated MLC alone did not influence the secretion of TNF-alpha, but it enhanced secretion of IL-1beta and IL-8 about 30-fold compared to background levels. Both PE and titanium particles significantly enhanced MLC cytokine release, the amount of which depended on the concentration of particles. Using 40 X 10(8) PE particles (0.7 x 10(8) titanium particles) and 10(6) MLC, the maximal release of IL-1beta was about 20-fold (7-fold titanium particles) higher than that of the rotating control sample. The stimulation of IL-8 release was 4-fold (3-fold titanium particles) and of TNF-alpha. 300-fold (170-fold titanium particles) compared to controls. MLC were viable (>90% cell survival) at concentrations less than 108 x 10(8) polyethylene particles per 10(6) MLC and 16 x 10(8) titanium particles per 10(6) MLC. Rotation per se as well as exposure to increasing concentrations of PE and titanium particles stimulates cytokine release (TNF-alpha, IL-1beta, IL-8) by macrophages in vitro. This in vitro model resembles the in vivo situation near arthroplasties, where implant particles make contact with inflammatory cells, such as macrophages. Cytokine release by macrophages may impair osteoblast function as well as stimulate bone resorption by osteoclasts and macrophages, thereby causing aseptic loosening of arthroplasties. Our in vitro model provides a reproducible human cell system that might shed light on the pathogenesis of particle disease and might serve as a reproducible in vitro test system for the biocompatibility of foreign materials.

Cell Culture Techniques↗

Mechanical properties of several nickel-titanium alloy wires in three-point bending tests.

The purpose of this study was to clarify the mechanical properties of 42 brands of nickel-titanium alloy orthodontic wires from 9 manufacturers by conducting three-point bending tests under uniform testing conditions. Manufacturers included A-Company, Hoya Medical, Lancer, Ormco, Rocky Mountain, Sankin, Tomy (GAC), TP, and 3M/Unitek. Cobalt-chrome, and titanium-molybdenum alloy wires were also tested as a reference for comparison of force levels. All reported data were recorded during the unloading process to simulate the force that a wire exerts on a tooth as it is moved into the dental arch from a position of malocclusion. The following results were obtained for the nickel-titanium wires tested. (1) Among the 0.016 inch round wires tested under a maximum deflection of 1.5 mm, the difference between the smallest (Copper nickel-titanium 35) and the largest (Aline) load values was 136 g. For the 0.016 x 0.022 inch rectangular wires tested, the difference between the smallest (Copper nickel-titanium 40) and the largest (Aline) load values was 337 g. (2) The change in load between 1.5 and 0.5 mm of deflection was examined to clarify the superelastic properties of the wires tested. For the 0.016 inch wires, 17 wire brands produced a load difference of less than 100 g, and two brands produced a difference of at least 100 g (Aline and Titanal = 100 g). For the 0.016 x 0.022 inch wires, 15 brands produced a load difference of less than 100 g, and eight brands produced a difference of over 100 g. The smallest and largest load differences were 3 g (Copper nickel-titanium 35) and 200 g (Aline). (3) The majority of the samples with a smaller load difference between deflections of 1.5 mm and 0.5 mm in the unloading process were found among super-elastic wires, while samples with a larger load difference were predominantly found among work-hardened wires. Compared with cobalt-chrome and TMA wires, nickel-titanium alloy wires exert significantly less force. However, the amount of force varies greatly from brand to brand. Consequently, when using nickel-titanium alloy wires, brands must be selected carefully by taking into consideration the severity of the malocclusion and the stage of orthodontic treatment in each case. It is the intent of this study to offer clinicians an unbiased guide for the selection of appropriate nickel-titanium alloy wires.

Dental Alloys↗

Effects of surface roughness of titanium implants on bone remodeling activity of femur in rabbits.

We investigated the bone remodeling activity on titanium implants with different surface roughnesses using a confocal laser scanning microscope (CLSM). Two kinds of implants were used, the machined smooth-surfaced titanium and the plasma-sprayed rough-surfaced titanium. These implants were randomly inserted in a rabbit's femur from the lateral aspect of the diaphysis bicortically. Rabbits were killed at 6, 16, and 42 weeks after surgery. The implant-bone blocks were embedded in polyester resin, and were prepared to make undecalcified ground sections. Histomorphometric analyses were performed at the cortical bone-implant interface using the image obtained by CLSM. Percentages of direct bone-implant contact and bone volume (BV/TV) around the implant was greater in rough-surfaced titanium compared with the smooth-surfaced titanium at 42 weeks after implantation. On the contrary, the eroded surface (ES/BS) appeared to be less in the rough-surfaced titanium than in the smooth-surfaced titanium at 6 weeks after implantation, but thereafter, no difference was found between the two kinds of implants. Mineralizing surface (MS/BS) and mineral apposition rate (MAR) showed no significant differences throughout the experimental period. These results indicate that increased bone volume in the rabbits of rough-surfaced titanium implants is due to less remodeling activity during the early stage after implantation compared with the smooth-surfaced implants. The surface roughness of titanium is one factor which helps in determining the balance between bone formation and resorption of remodeling at the interface of the bone implants.

Animals↗