Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Suction”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14Linked to original sources

[The ultrastructure changes of rabbit retina after periodical vacuum suction].

OBJECTIVE: To study the effects of periodical vacuum-suction of different pressures on the ultrastructure of rabbits' retina. METHODS: Rabbits involved in the present study were divided into a control group and four treatment groups, which were treated with vacuum-suction of different pressures through scleral suction ring. The suction pressure was increased at a rate of 100 mm Hg/3 sec (1 mm Hg = 0.133 kPa) and reached (200 +/- 20) mm Hg (group I), (300 +/- 20) mm Hg (group II); (400 +/- 20) mm Hg (group III) and (500 +/- 20) mm Hg (group IV). The suction pressure was maintained for 5 seconds before released to zero. The corresponding intraocular pressure examined by Tonopen was 35 mm Hg, 45 mm Hg, 55 mm Hg and 75 mm Hg in these 4 groups, respectively. This circle was repeated for 10 times with 1 minute interval. The test was repeated every other day. The retina was examined by electron microscope after 2 weeks. RESULTS: There was no obvious difference in the retina ultrastructure between the control group and group I. The retina ultrastructure changed slightly in group II which showed more active metabolism. Some significant changes were found in group III and group IV with cell necrosis in group IV. CONCLUSION: Different elevations of intraocular pressure following periodical vacuum-suction have different effects on the retina of rabbit. Pressure less than 45 mm Hg has almost no effect, but some effects appear at 55 mm Hg pressure, and obviously damages are caused by 75 mm Hg pressure.

Animals↗

Intratracheal suctioning, systemic infection, and the meconium aspiration syndrome.

A retrospective analysis was performed to determine: (1) the proportion of neonates with the meconium aspiration syndrome (MAS) who were not depressed at birth; (2) to evaluate the clinical course of neonates with MAS, particularly relating to whether or not delivery room intubation and intratracheal suctioning had taken place; and (3) to examine the incidence of culture-proven bacteremia among meconium-stained neonates and those with MAS. The medical records of all meconium-stained neonates and those with MAS admitted to our facility from 1985 through 1989 were reviewed. Of 5697 liveborn neonates, 741 (13%) were meconium-stained, of whom 608 (82%) were intubated and suctioned in the delivery room. No complications of the intubation/suctioning procedure were noted in these neonates. Forty-five neonates had culture-proven bacteremia. Five bacteremic neonates had been meconium-stained (0.7% of all such neonates), while 40 were not stained (0.8% incidence). Of 36 neonates with MAS, 1 (2.8%) was bacteremic. Twenty (56%) of 36 newborns with MAS did not require positive pressure ventilation in the delivery room. Twelve (33%) of the babies with MAS had not been intubated and suctioned in the delivery room. Nine (75%) of 12 nonsuctioned neonates, as well as 6 (25%) of 24 suctioned neonates, required mechanical ventilation for more than 6 hours (P = .010). Pneumothoraces occurred in 6 (50%) of 12 nonsuctioned and 5 (21%) of 24 suctioned babies (P = .125). Four of 12 nonsuctioned newborns either died (n = 1) or required extracorporeal membrane oxygenation (n = 3), while only 1 of the suctioned newborns required extracorporeal membrane oxygenation (P = .034).(ABSTRACT TRUNCATED AT 250 WORDS)

Apgar Score↗

[Effects of respiratory physical therapy and nasopharyngeal suction on gastroesophageal reflux in infants less than a year of age, with or without abnormal reflux].

The purpose of this study was to analyse the effects on gastro-oesophageal reflux (GOR) of the different manipulations used during pulmonary physical therapy (nasal suctions, oropharyngeal suctions, acceleration of expiratory flow). 115 children less than 1 year old, were divided into two groups according to the results of oesophageal pH monitoring: 44 with and 61 without pathological GOR. Nasal suctions did not significantly increase GOR in children without pathological GOR. Oropharyngeal suctions increased GOR significantly more than nasal suctions (*p = 0.031). The technique of acceleration of expiratory flow, used in 35 degrees verticalized position and supine position, increased the index of reflux and the time with oesophageal pH below 4 in children with pathological GOR. However it did not increase reflux in normal children. The index of induced reflux in the whole population was increased in the horizontal position (4.81 +/- 0.88 reflux/hour) as compared with 35 degrees verticalized (2.92 +/- 0.79 reflux/hour). These oesophageal pH measurements confirm the clinical observations often made during physical therapy (vomiting, regurgitations, reflex cough). This statistical study suggests that one should take into account the adverse factor of GOR secondary to pulmonary physical therapy. It seems better to use nasal rather than oropharyngeal suctions and also to use the acceleration of expiratory flow technique in the 35 degrees verticalized rather than in the supine position, even more so if a pathological reflux does exist.

Gastroesophageal Reflux↗

[Gravity drainage versus suction drainage: an experimental and clinical study].

The importance of wound drainage in casualty and plastic surgery is unquestioned. The most common form is suction drainage. This involves the disadvantage that the drain can become attached to the tissue by suction, stopping the flow and blocking the drain. In addition, the secretion reservoir must be made of rigid material, which means large package sizes are inevitable. Encouraged by our knowledge of silicone drains, we carried out a study comparing silicone drains (without vacuum) and PVC drains (with vacuum suction). Electron-microscope studies of the PVC drains used for suction drainage revealed adhesion of wound secretion and cell detritus to the inner wall and the drainage perforations after less than 24 h. No occlusion and almost no adherence was observed with silicone gravity drains. When compared in clinical use for joint drainage, neither system had any severe complications. Removal of gravity drains was considerably less painful than withdrawal of suction drains. In soft tissue drainage the volume of secretion drained off was more constant and obviously larger with gravity drainage. From these results we conclude that gravity drainage can replace suction drainage to considerable advantage.

Clinical Trials as Topic↗

Arterial blood gas changes with a hyperinflation and hyperoxygenation suctioning intervention in critically ill patients.

Limited data are available on the efficacy of a common endotracheal suctioning intervention to prevent postsuctioning decreases in arterial oxygenation (PaO2). This study evaluated the effect on Pao2 of five hyperinflation (tidal volume 1.5 times normal) and hyperoxygenation breaths, administered before and after each of two consecutive endotracheal suctioning passes, with use of a manual resuscitation bag (PMR-2 model). The convenience sample consisted of 32 patients with endotracheal tubes who were observed within 24 hours of coronary artery bypass surgery. After the implementation of this standard suctioning intervention, there was a significant increase in PaO2 from baseline values. Only one subject had a decrease in PaO2 (44 mm Hg) after the intervention. In addition, a clinical measure of alveolar-capillary gas exchange (PaO2/PAO2 ratio) was found to be a significant predictor of PaO2 after suctioning, accounting for 38% of the variance. The data from this study support the efficacy of administering five hyperinflation and hyperoxygenation breaths, with use of a manual resuscitation bag, before and after endotracheal suctioning in stable patients after coronary artery bypass surgery. Further study is necessary to determine the efficacy of this suctioning intervention in patients with other respiratory problems.

Adult↗

Increased resistance of hygroscopic condenser humidifiers when using a closed circuit suction system.

OBJECTIVES: To examine a hygroscopic condenser after clinical use and to describe the interaction of a hygroscopic condenser and a closed circuit suction system used simultaneously. DESIGN: Prospective evaluation of hygroscopic condensers used clinically, and laboratory investigation of a hygroscopic condenser used with a closed circuit suction system. SETTING: Tertiary referral centers. MEASUREMENTS AND MAIN RESULTS: The hygroscopic condenser used during mechanical ventilation was removed and peak inflation pressure was measured by delivering a standard tidal volume and inspiratory flow across the isolated hygroscopic condenser while recording the peak inflation pressure. In the laboratory, four 10-mL aliquots of saline were instilled via closed circuit suction system into a test lung with fresh hygroscopic condensers (n = 15) inline. At baseline and after each instillation, the hygroscopic condenser was weighed and the peak inflation pressure was measured while in five condensers, peak expiratory flow rate was also measured. In these five devices, hygroscopic condenser resistance was measured with 100 L/min of constant gas flow while measuring the pressure drop across the hygroscopic condenser. In 11 hygroscopic condensers used for 27.5 +/- 11.9 hrs with no closed circuit suction system, the peak inflation pressure was 3.74 +/- 0.58 cm H2O. In the laboratory, instillation of saline via closed circuit suction system was associated with an increase in hygroscopic condenser weight. Peak inflation pressure increased in a quadratic fashion with the increase in hygroscopic condenser weight, while peak expiratory flow rate decreased in a linear fashion. After four saline instillations, hygroscopic condenser resistance increased from 5.66 +/- 0.31 to 13.9 +/- 2.42 cm H2O/L/sec. CONCLUSIONS: Clinical use of a hygroscopic condenser alone is not associated with a significant increase in peak inflation pressure. We caution the use of a hygroscopic condenser and a closed circuit suction system simultaneously, as an increase in hygroscopic condenser resistance may develop and may be poorly tolerated in patients with marginal ventilatory reserve.

Aged↗

Nasopharyngeal suction study reveals knowledge deficit.

Nasopharyngeal suction is carried out frequently in paediatric practice. A questionnaire survey was distributed to nurses and physiotherapists at The Royal Hospital for Sick Children in Edinburgh to ascertain the extent of their knowledge in the theory and practice of suctioning. Results revealed several problem areas in use of nasopharyngeal suction at this hospital. There was significant disagreement over appropriate catheter size, suction pressure and method of suction as well as use of pre-oxygenation and knowledge of adverse effects. The results indicate that further theoretical and practical education is needed in the use of nasopharyngeal suction and that a standard method should be implemented throughout the hospital.

Child↗

Endotracheal suctioning: ventilator vs manual delivery of hyperoxygenation breaths.

BACKGROUND: Despite a large number of studies on endotracheal suctioning, there is little data on the impact of clinically practical hyperoxygenation techniques on physiologic parameters in critically ill patients. OBJECTIVE: To compare the manual and mechanical delivery of hyperoxygenation before and after endotracheal suctioning using methods commonly employed in clinical practice. METHODS: A quasi-experimental design was used, with twenty-nine ventilated patients with a lung injury index of 1.54 (mild-moderate lung injury). Three breaths were given before and after each of two suction catheter passes using both the manual resuscitation bag and the ventilator. Arterial pressure, capillary oxygen saturation, heart rate, and cardiac rhythm were monitored for 1 minute prior to the intervention to obtain a baseline, continuously throughout the procedure, and for 3 minutes afterward. Arterial blood gases were collected immediately prior to the suctioning intervention, immediately after, and at 30, 60, 120, and 180 seconds after the intervention. Data were analyzed with repeated measures analysis of variance. RESULTS: Arterial oxygen partial pressures were significantly higher using the ventilator method. Peak inspiratory pressures during hyperoxygenation were significantly higher with the manual resuscitation bag method. Significant increases were observed in mean arterial pressure during and after suctioning, with both delivery methods, with no difference between methods. Maximal increases in arterial oxygen partial pressure and arterial oxygen saturation occurred 30 seconds after hyperoxygenation, falling to baseline values at 3 minutes for both methods. CONCLUSION: Using techniques currently employed in clinical practice, these findings support the use of the patient's ventilator for hyperoxygenation during suctioning.

Adult↗

A survey of endotracheal suctioning with instillation of normal saline.

BACKGROUND: Instillation of normal saline before suctioning is a common nursing intervention although little research supports the practice. OBJECTIVES: To determine when and how often saline is used during suctioning and to assess the knowledge of nurses and respiratory therapists of the advantages and dangers of using saline during endotracheal suctioning. METHODS: A survey of nurses and respiratory therapists working in adult ICUs was conducted in a large university teaching hospital. RESULTS: Of the 187 respondents, 96 (51%) rarely instill saline before suctioning, whereas 61 (33%) frequently use saline. Fifty-five percent use saline to enhance retrieval of secretions, and 45% use it to stimulate a cough. Nurses and respiratory therapists differ in their use and understanding of saline instillation. Most nurses (64%) rarely use saline before suctioning, whereas most respiratory therapists (71%) frequently use saline. Respiratory therapists (57%) were more aware than were nurses (37%) of the benefit of using normal saline to stimulate a cough. Nurses indicated more adverse effects of instillation of normal saline, specifically oxygen desaturation and increased risk of pulmonary infections, than did respiratory therapists. CONCLUSION: The results of the survey helped determine target areas for educational programs for nurses and respiratory therapists. A protocol is being developed for use by all who do suctioning.

Adult↗

Ontogeny of suction feeding capacity in snook, Centropomus undecimalis.

The ontogeny of suction feeding performance, as measured by peak suction generating capacity, was studied in the common snook, Centropomus undecimalis. Suction pressure inside the buccal cavity is a function of the total expansive force exerted on the buccal cavity distributed across the projected area of the buccal cavity. Thus, the scaling exponent of peak suction pressure with fish standard length was predicted to be equal to the scaling exponent of sternohyoideus muscle cross-sectional area, found to be 1.991, minus the scaling exponent for the projected buccal cavity area, found to be 2.009, equal to -0.018. No scaling was found in peak suction pressure generated by 12 snook ranging from 94 to 314 mm SL, supporting the prediction from morphology. C. undecimalis are able to generate similar suction pressures throughout ontogeny.

Animals↗

Abdominolipoplasty: a system of classification and treatment for combined abdominoplasty and suction-assisted lipectomy.

Criteria for diagnosing abdominal contouring candidates and a new classification system for procedures are presented. The surgical techniques for each of four patient categories of abdominolipoplasty are reviewed: type I--suction-assisted lipectomy alone, type II--mini-abdominoplasty, type III--modified abdominoplasty, and type IV--abdominoplasty with suction-assisted lipectomy. With the combination of suction-assisted lipectomy and abdominoplasty, the majority of patients can actually be treated with a limited abdominoplasty procedure or suction lipectomy. Complications noted in a series of 75 consecutive patients operated on by one surgeon are presented. The blood supply that is relevant to a combination of suction lipectomy with abdominoplasty is outlined. Specific guidelines for these combined procedures are recommended in order to safely combine full abdominoplasties with suction-assisted lipectomies.

Abdomen↗

Comparison of suction capsule and endoscopic biopsy of small bowel mucosa.

Small bowel mucosal biopsy specimens were studied in 52 consecutive patients. Twenty-six patients underwent biopsy by a suction capsule and 16 patients by endoscopy using an 8-mm forceps. Additionally, 10 patients were asked to undergo biopsy by both techniques in the same morning. Material was obtained in 81% of attempts by suction and 100% by endoscopy. Tissue obtained was excellent in 58%, good in 28%, and poor in 14% of suction biopsy specimens. Corresponding grades for endoscopy were 65%, 31%, and 4%. The frequency of abnormal findings was not different by either technique. In the 10 patients who had both procedures, mean time to completion was 43 min by suction and 12 min by endoscopy. Intravenous premedication was used in endoscopy, and patient comfort was judged as excellent in 60% with endoscopy, whereas 60% judged suction biopsy as very uncomfortable. The mean fluoroscopy time of 3.9 min necessary for suction biopsy was eliminated with endoscopy. Biopsy with an 8-mm forceps through the endoscope is the preferred way to obtain tissue from the proximal small bowel.

Biopsy↗

Difficulties with portable suction equipment used for prehospital advanced airway procedures.

INTRODUCTION: Airway management is the highest priority for prehospital personnel. While different modalities for airway management are under investigation, endotracheal intubation remains the standard for definitive airway protection. Currently, airway adjuncts such as portable suction remain relatively unstudied. OBJECTIVE: To identify utilization and complications associated with portable suction equipment used by prehospital medical personnel. METHODS: Fifty-one paramedics serving a Level I urban trauma center were anonymously surveyed to determine types of equipment used, maintenance and utilization patterns, difficulties encountered, and training received with that equipment. RESULTS: The paramedics reported carrying suction equipment to the scene of medical aid calls less than 25% of the time. Once on scene, suction equipment is utilized during 50% of advanced airway procedures. Half of the paramedics reported complications affecting patient care at least once during their careers due to equipment malfunction. Ninety-eight percent of the paramedics reported having some type of training with the suction equipment for prehospital advanced airway procedures. CONCLUSIONS: The results of this study suggest that suction equipment is carried to the scene infrequently and, when employed, is often found to be functioning suboptimally. Suggestions for improvement and further investigation are provided.

California↗

Evaluation of a closed-tracheal suction system.

A new tracheo-bronchial closed-suction system has been recently introduced. The Trach Care catheter can be connected to the endotracheal tube of a patient on mechanical ventilation and be left in place as long as 24 h. Thus, suctioning does not require disconnection from the mechanical ventilator. We evaluated the benefits of this new system in 20 patients receiving mechanical ventilation; ten patients required PEEP of 10 cm H2O and under, while the other ten patients needed PEEP over 10 cm H2O to maintain acceptable oxygenation. PaCO2, arterial oxygen saturation, and alveolar-arterial oxygen tension difference were measured before and after suctioning, using a conventional catheter and the Trach Care closed-suction method. Oxygenation only deteriorated when the open technique was used in patients receiving over 10 cm H2O of PEEP. The changes were statistically, but not clinically, significant. The Trach Care system is approximately 25 times as expensive as conventional suctions catheter, so its use cannot be justified economically. A potential advantage of the technique is preventing the dissemination of contaminated secretions, which are dispersed when the patient is disconnected from the ventilator and inspiratory gas flow persists. While no universal advantage of the closed-suction system was found, potential benefits may be considered on a case-by-case basis.

Critical Care↗

A prospective, randomized, double-blind, controlled clinical trial comparing laser-assisted lipoplasty with suction-assisted lipoplasty.

BACKGROUND: The authors randomized and prospectively analyzed their clinical experience with the use of internal neodymium:yttrium-aluminum-garnet low-level laser-assisted lipoplasty compared with suction-assisted lipoplasty. METHODS: Suction-assisted lipoplasty was generated through a SmartLipo machine and delivered into the subcutaneous tissues through 2-mm solid optical probes. Ipsilateral suction-assisted lipoplasty and contralateral laser-assisted lipoplasty were performed on one or more comparable topographic areas of the body in the same patient. Laser-assisted lipoplasty and suction-assisted lipoplasty sides of 25 patients were compared with preoperative and postoperative photographs at 3 to 5 days, 12 to 15 days, and 6 to 11 months. Statistical analysis considered surgeon and patient satisfaction, time used in the procedures, learning curves, lipocrits, operative technique, postoperative pain, edema, ecchymosis, time of recovery, body mass index, DNA proteins, free fatty acids, and cytologic patterns of post-laser-assisted lipoplasty and suction-assisted lipoplasty adipocyte architecture. Photographs were sent to the patients (blinded to the operated sides) and two plastic surgeons unfamiliar with the cases for evaluation of results. RESULTS: All patients completed the preestablished follow-ups. No complications were observed. Less pain, lower lipocrits, higher triglycerides, and DNA cellular membrane traces were detected in the laser-assisted lipoplasty sides. All other considerations studied showed no differences with either technique in the three periods of the follow-up controls. Cytologic studies showed more damage of the adipocytes in the laser-assisted lipoplasty sides. CONCLUSIONS: No major clinical differences for suction-assisted lipoplasty versus laser-assisted lipoplasty were found. Higher concentrations of free-fatty acids after laser-assisted lipoplasty must alert us to possible hepatic and renal toxicity.

Adult↗

Surgical treatment of axillary hyperhidrosis: a study comparing liposuction cannulas with a suction-curettage cannula.

BACKGROUND: Suction-curettage is a minimally invasive surgical approach for the treatment of focal axillary hyperhidrosis. Studies comparing the efficacy of different surgical cannulas are missing. Therefore, we gravimetrically compared a specially designed cannula versus 2 standard liposuction cannulas. METHODS: Axillary suction-curettage was performed in 42 patients (n = 42). Fourteen patients (n = 14) were operated with a 1-hole liposuction cannula, 14 patients (n = 14) with a larger 3-hole liposuction cannula, and 14 (n = 14) with a sharp suction-curettage cannula. Sweat rates in mg/min were measured by gravimetry before and 6 months after surgery. RESULTS: Sweat rate in the 1-hole liposuction cannula group was significantly reduced from 57.65 +/- 5.85 mg/min to 32.58 +/- 4.64 mg/min (P < 0.001), corresponding to a reduction of 44.15%. Patients operated with the larger 3-hole liposuction cannula showed a significant reduction of sweat rate from 63.95 +/- 8.25 mg/min to 33.14 +/- 6.25 mg/min (P < 0.001), corresponding to a reduction of 49.19%. The largest reduction of sweat rates (63.07%) was achieved with the suction-curettage cannula (61.85 +/- 9.03 mg/min to 21.27 +/- 4.42 mg/min (P < 0.001). No severe side effects were observed. CONCLUSION: Due to the higher efficacy we recommend performing suction-curettage with a sharp suction-curettage cannula.

Adult↗

Hydrodynamic modelling of aquatic suction performance and intra-oral pressures: limitations for comparative studies.

The magnitude of sub-ambient pressure inside the bucco-pharyngeal cavity of aquatic animals is generally considered a valuable metric of suction feeding performance. However, these pressures do not provide a direct indication of the effect of the suction act on the movement of the prey item. Especially when comparing suction performance of animals with differences in the shape of the expanding bucco-pharyngeal cavity, the link between speed of expansion, water velocity, force exerted on the prey and intra-oral pressure remains obscure. By using mathematical models of the heads of catfishes, a morphologically diverse group of aquatic suction feeders, these relationships were tested. The kinematics of these models were fine-tuned to transport a given prey towards the mouth in the same way. Next, the calculated pressures inside these models were compared. The results show that no simple relationship exists between the amount of generated sub-ambient pressure and the force exerted on the prey during suction feeding, unless animals of the same species are compared. Therefore, for evaluating suction performance in aquatic animals in future studies, the focus should be on the flow velocities in front of the mouth, for which a direct relationship exists with the hydrodynamic force exerted on prey.

Animals↗

The localization of the bullous pemphigoid and cicatricial pemphigoid antigens: direct and indirect immunofluorescence of suction blisters.

The location of in vivo bound immunoreactants was studied in 37 patients with subepidermal blistering diseases by direct immunofluorescence (IMF) on suction blisters taken from uninvolved forearm skin. The patients studied included 18 with bullous pemphigoid (BP), nine with cicatricial pemphigoid (CP), three with acquired epidermolysis bullosa (EBA) and 7 hybrid cases. The patterns of IMF in the suction blisters were: BP, epidermal 1, dermal 1, combined 4, negative 12; CP, epidermal 1, dermal 2, negative 6; EBA, dermal 2, negative 1; and 'hybrid' patients, epidermal 3, negative 4. The different patterns of suction blister staining could not be correlated with the clinical features of the patients in respect of mucous membrane involvement, scars or milia or a history of skin fragility. Both BP and CP are probably heterogeneous in respect of their antigen specificity, and the two diseases cannot reliably be distinguished by the patterns of direct IMF on suction blisters. In addition, some individual patients with BP have more than one target antigen as indicated by a combined pattern of suction blister fluorescence. The lack of correlation between the pattern of suction blister fluorescence and the clinical features suggests that factors other than antigen specificity determine the clinical expression of subepidermal blistering diseases.

Adult↗