Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “SEALS”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14Linked to original sources

Organochlorine concentrations in the Saimaa ringed seal (Phoca hispida saimensis) from Lake Haukivesi, Finland, 1981 to 2000, and in its diet today.

Organochlorine and mercury (Hg) pollution has been one possible reason for a decline in the size of the population of the Saimaa ringed seal (Phoca hispida saimensis) in Lake Haukivesi, Finland. In this study, we analyzed changes in the concentrations of organochlorine compounds (OCls) and extractable organic halogen (EOX) in the blubber of Saimaa ringed seals that died from 1981 to 2000. In addition, the present concentrations and biomagnification factors of OCls and Hg from the main prey fish of ringed seal and pike (Esox lucius) were determined. Concentrations of pollutants in bream (Abramis brama) also were analyzed. The decline in the OCl concentrations in blubber was, on average, 25% during the two decades since polychlorinated biphenyls and DDT compounds were banned. Today, concentrations in blubber of Saimaa ringed seals are similar of those in ringed seals from the Arctic. Correspondingly in fish, the OCl and Hg concentrations were, on average, similar to those found in other studies on Finnish and Arctic areas. The low diet concentrations and metabolism of OCls also reflect the lower age correlation of OCls in the male ringed seals in the 1990s than in the 1980s. Biomagnification was considerably higher from fish to the ringed seal than from prey fish to pike because of higher feeding rate of ringed seals and differences in the metabolisms of these animals.

Adipose Tissue↗

Blood rheology of Weddell seals and bowhead whales.

Red blood cell (RBC) aggregation and blood viscosity are important determinants of in vivo blood flow dynamics and, in marine mammals, these parameters may impact diving physiology by altering blood oxygen delivery during the diving response. Weddell seals are superb divers and exhibit age-related patterns in blood oxygen chemistry and diving ability. By contrast, bowhead whales are not long duration divers, and little is known of their blood properties relative to diving. The present study was designed to compare rheological characteristics of blood from Weddell seal pups, Weddell seal adults, and from adult bowhead whales: blood viscosity and RBC aggregation in plasma and in polymer solutions (i.e., RBC "aggregability") were measured. Salient findings included: (1) significant 4- to 8-fold greater aggregation in blood from adult seals compared with pups and human subjects; (2) 2-to 8-fold greater aggregation in bowhead whale blood compared with human blood; (3) compared to human red cells, enhanced RBC aggregability of RBC from adult seals and whales as determined by their greater aggregation in polymer solutions; (4) increasing RBC aggregation and aggregability of seal pup blood over a seven day period following birth; (5) significantly greater blood viscosity for adult seals compared with pups at both native and standardized hematocrits. These results indicate that, for both species, hemorheological parameters differ markedly from those of humans, and suggest progressive changes with seal age; the physiological implications of these differences have yet to be fully defined.

Adult↗

Investigation of shear-peel bond strength of orthodontic brackets on enamel after using Pro Seal.

AIM: The aim of this investigation was to ascertain whether the use of a fluoride-releasing, light-curing sealant (Pro Seal, Reliance Orthodontic Products, Itasca, IL, USA) results in differences in shear-peel bond strength when teeth are etched via the conventional acid-etching method and with self-etching primers (SEP), respectively. We also examined whether Pro Seal functions as a substitute for the bonding agents recommended by the manufacturers. MATERIAL AND METHODS: To carry out this study, we randomly allocated 300 extracted molars (ISO 11405) into twelve groups (n=25). The brackets used (Victory Series, Twin UBi 0T/0A .022, 3M Unitek, Seefeld, Germany) were bonded using the same layer thickness of adhesive. The teeth were then stored for 24 h in de-ionized water (37 degrees C) and subsequently thermocycled. The brackets were debonded using a universal testing machine with a crosshead speed of 0.5 mm/min. For statistical evaluation we used the one-way analysis of variance (ANOVA [alpha = 0.05]) and the post hoc Tukey test and Weibull analysis. RESULTS: We could establish that the use of Pro Seal does not have a negative influence on shear-peel bond strength. When the compomer Assure was used, Pro Seal even led to an increase in shear-peel bond strength, especially when it was applied using the bonding agent recommended by the manufacturer. The highest Weibull modulus (m) was found for the self-etching primer IDEAL 1 without using Pro Seal (m=6.5) and the lowest for First Step SEP when using Pro Seal (m=2.2). There were also clear differences in characteristic shear-peel bond strength (sigma(0)) within some of the groups investigated. CONCLUSIONS: Although the statistical evaluation showed no significant negative influence on the shear-peel bond strength either when Pro Seal was used in addition, or when that fluoride-releasing, light-curing sealant was substituted for the bonding agent recommended by the manufacturer, the Weibull analysis showed that the use of Pro Seal in combination with SEP resulted in bond strength values that were less reliably reproducible.

Orthodontic Brackets↗

Polychlorinated naphthalenes and coplanar polychlorinated biphenyls in tissues of harbor seals (Phoca vitulina) from the northern Gulf of Alaska.

Blubber, liver and kidney samples of harbor seals (Phoca vitulina) from the northern Gulf of Alaska were collected during 2000-2001 for the analysis of polychlorinated naphthalenes (PCNs) and coplanar polychlorinated biphenyls (CoplPCBs). On the lipid weight (lw) base, the total concentrations of PCNs (Sigma PCNs) ranged from 0.3 to 27 ng/g lw, and the total concentrations of CoplPCBs (Sigma CoplPCBs) were 3.6-546 ng/g lw in all the tissue samples. Di-ortho PCBs and mono-ortho PCBs were dominant followed by non-ortho PCBs and PCNs. Sigma Mono-ortho PCBs and Sigma di-ortho PCBs in nursing seals were apparently lower than those in male adult seals, but Sigma PCNs and Sigma non-ortho PCBs in female adults were not significantly different from those in male adults. Differences in PCNs and CoplPCBs congener profiles in female and male adult seals are apparently related to their chemical structure and properties, animal's developmental stages and physiological conditions. A large quantity of mono-ortho and di-ortho PCBs might be transferred to newborns from the nursing seals during lactation, while non-ortho PCBs and PCNs were relatively accumulative in the mother seals. Sigma PCNs and Sigma CoplPCBs in the harbor seals correlated with ages, gender, body weight and blubber thickness, but the blubber Sigma PCNs and Sigma CoplPCBs in Kodiak Island and Southern Alaska Peninsula (KIAP) did not significantly differ from those in Prince William Sound (PWS). In addition to the new PCB data, this first report on PCN contamination in Alaskan harbor seal tissues is useful for the wildlife and ecosystem management and human health protection.

Adipose Tissue↗

The sealing effect of fibrin glue against alveolar air leakage evaluated up to 48 h; comparison between different methods of application.

OBJECTIVE: There is little experimental evidence to show how much positive airway pressure fibrin sealants can actually withstand, and in particular, how this effect changes over time. In the present study, we experimentally evaluated the sealing effect of fibrin glue against alveolar air leakage up to 48 h after application. METHODS: Beagles were used (n = 48). Under thoracotomy, approximately 5 x 10 mm defects (2 mm depth) were made on the lung surface. Fibrin glue sealants were applied to this defect in three ways. In rubbing and spray method, fibrinogen was rubbed, followed by spraying of both fibrinogen and thrombin solutions. In double layer method, fibrinogen was dripped, followed by thrombin. Collagen fleece, coated with fibrinogen and thrombin (TachoComb) was also tested. The minimum positive airway pressure which produced air leakage was measured for each sealed defect (seal breaking pressure, cmH2O) at 0, 3, 6, 12, 24, and 48 h after application (n = 6 at each time point). RESULTS: The seal-breaking pressure increased over time in all of the application methods. At 6 h, differences between methods were not significant but three defects in RS reached 70 cmH2O, the maximum pressure tested, compared with none in other two methods. At 12h, the seal-breaking pressure was significantly higher in RS compared with the other two methods (rubbing and spray method vs TachoComb; 66+/-3 vs 47+/-17, P = 0.047, rubbing and spray method vs double layer method; 66+/-3 vs 42+/-18, P = 0.024). Beyond 24 h, sealing pressure reached close to 70 cmH2O in all the methods. CONCLUSIONS: The results show that the sealing effect of fibrin glue is relatively unstable up to 12h after its application. Rubbing and spray method may help the fibrin seal to reach its full strength faster compared with the other two methods.

Aerosols↗

New applications of the laser in pulmonary surgery: hemostasis and sealing of air leaks.

In thoracic surgery, the laser has been used primarily as a destructive instrument (e.g., for extirpation of endobronchial lesions and for skin incisions). Previously, the carbon dioxide laser was used for its scalpel-like action but not for sealing. The neodymium:yttrium aluminum garnet (Nd:YAG) laser not only cuts but also seals blood vessels and bronchi. We have modified the CO2 laser technique to seal vessels and bronchi up to 3 mm on a cut surface by using low power in a defocused mode, and have evaluated the method in 12 dogs. Matched lesions in the lingula were sealed with each type of laser and compared with lesions closed by suture technique. These lesions were then evaluated at biweekly intervals up to 6 weeks following operation. All lesions demonstrated substantial air leak and bleeding prior to sealing. There was no bleeding or air leak (40 cm H2O of pressure) at any time after sealing (laser or suture). The CO2 laser sealing consistently produced the least damage both macroscopically and microscopically. However, this technique requires a relatively bloodless field. The Nd:YAG laser produced the deepest tissue destruction but functioned well under conditions of poor hemostasis. Suture closure produced large early injuries, which subsided gradually to approach the amount of damage seen with the CO2 laser. These studies demonstrate that the laser may be a useful adjunct to maximally preserve normal lung tissue and to seal bleeding, leaking, raw lung surfaces. Results of early clinical trials are also detailed.

Aged↗

Temporary luminal arteriotomy seal: III. Postmortem arteriosclerotic human coronary artery.

BACKGROUND: Recently, we described a temporary luminal arteriotomy seal that provided a bloodless arteriotomy without obstructing recipient artery blood flow during bypass grafting in nonarteriosclerotic porcine arteries. This postmortem study assessed the sealing properties in irregular arteriosclerotic human coronary arteries. METHODS: Three hearts were obtained from donated corpses within 24 hours of death. The coronary arteries were pressure-perfused at 60 mm Hg with citrated porcine blood. At 15 anastomosis sites in four different coronary arteries, an end-to-side anastomosis was created using a 200-microm-thick polyurethane seal. Adequacy of sealing was determined at perfusion pressures of 60, 40, and 20 mm Hg. RESULTS: After insertion, the arteriotomy was sealed instantaneously in 10 of 15 anastomoses. After repositioning, complete sealing with a bloodless operative field was obtained in all cases. Low intracoronary transmural pressure did not impede sealing. In 8 of 15 anastomoses, minor leakage without obscuring the arteriotomy edges was observed during anastomotic suturing. Histologic examination revealed no intimal tear or dissection caused by the anastomotic procedure. CONCLUSIONS: In postmortem-obtained arteriosclerotic human coronary arteries, the temporary luminal arteriotomy seal provided optimal visualization of the coronary anastomosis site in combination with persistent distal perfusion.

Aged↗

Plasma angiotensin II, arginine vasopressin and atrial natriuretic peptide in free ranging and captive seals and sea lions.

We used radioimmunoassay methods to quantify arginine vasopressin (AVP), atrial natriuretic peptide (ANP), and angiotensin II (Ang II) in plasma samples from harbor seals (Phoca vitulina richardsii), Weddell seals (Leptonychotes weddellii), northern elephant seals (Mirounga angustirostris), ringed seals (Phoca hispida), California sea lions (Zalophus californianus), and Steller sea lions (Eumetopias jubatus). Plasma concentrations of AVP, ANP, and Ang II in these pinniped species were within the ranges reported for other vertebrates under resting conditions. However, there were species, geographic and developmental variations in these hormones: Levels of AVP in plasma samples from adult Steller sea lions and harbor seals were higher than in pups of the same species; higher levels of plasma ANP were found in wild captured Alaskan Steller sea lions and in hunted ringed seals; differences in plasma levels of all three hormones were found throughout the geographic distribution of harbor seals and Steller sea lions in Alaska. This is the first report on circulating concentrations of vasoactive hormones in pinnipeds, and demonstrates that further studies are needed to ascertain the natural variability in these levels with the impact of molting, fasting, diving and environmental factors in seals and sea lions.

Angiotensin II↗

[Christmas seals].

Christmas seals, i. e., special stamps used to decorate or seal Christmas and New Year's mail, were created by the Danish post office clerk E. Holboell. The proceeds from the sale of the stickers were meant to alleviate the suffering of children sick with tuberculosis. The first Christmas seal, showing a portrait of Queen Louise of Denmark, was issued on December 10, 1904. The demand at the post office was enormous. The funds raised exceeded all expectations and made it possible to finance the construction of a sanatorium for tuberculosis children. The idea of Christmas seals spread quickly around the world and ended up being copied in 130 countries. At the beginning of the 20 (th) century, the small stamp with the red double-barred cross became a banner for the crusade against tuberculosis. For many patients, it also represented a symbol of hope for recovery even though this hope, given the cure rates of a sanatorium treatment, only became a reality for a few. Worldwide, Christmas seals were and are colourful and imaginatively designed, mostly with Christmas symbols or motives relating to the fight against tuberculosis. The funds raised through the sale of the seals initially helped to build hospitals and were later also used to screen persons at risk for tuberculosis, to improve housing conditions of patients and for other measures of support. With the decrease of tuberculosis, some organisations discontinued fundraising through Christmas seals while others widened their intended purpose and supported, for example, the prevention of and research on lung diseases. In Germany, Christmas seals are closely connected with the German Central Committee against Tuberculosis. Today the "Kuratorium Tuberkulose in der Welt" is the only organisation in this country that still raises funds by this means. The funds are mostly used to assist developing countries with a high burden of tuberculosis.

Art↗

Intrasac flow velocities predict sealing of type II endoleaks after endovascular abdominal aortic aneurysm repair.

PURPOSE: The purpose of this study was to determine whether intrasac spectral Doppler flow velocities can predict whether or not a type II endoleak will spontaneously seal and to relate intrasac flow to preoperative branch vessel anatomy. METHODS: Between October 1996 and June 2002, 265 patients with abdominal aortic aneurysms underwent endovascular repair. Patients with less than 24 months of follow-up and type I endoleaks were excluded. Type II endoleaks were confirmed with duplex scan and computed tomographic angiography. Two groups were identified: 14 patients with sealed endoleaks (<6 months) without intervention and 16 patients with persistent endoleaks greater than 6 months and without resolution. Spectral Doppler flow velocities were recorded from endoleaks within the aneurysm sac. RESULTS: The two groups were similar in age, demographics, and aneurysm morphology. The mean follow-up times were 29.9 +/- 7.9 months for sealed endoleaks and 30.2 +/- 8.6 months for persistent endoleaks (P = not significant). Spectral Doppler velocities were significantly lower in patients with sealed endoleaks compared with persistent endoleaks (75.5 +/- 78.8 cm/s versus 138.2 +/- 36.2 cm/s; P <.01). Patients with sealed endoleaks and low (<100 cm/s) intrasac Doppler velocities had significantly fewer patent inferior mesenteric arteries (43% versus 81%; P <.01), a smaller inferior mesenteric artery (5.6 +/- 1.8 mm versus 7.2 +/- 1.3 mm; P <.01), and fewer paired lumbar arteries (1.3 +/- 0.8 versus 2.4 +/- 0.6; P <.0001) compared with those with persistent endoleaks and high (>100 cm/s) intrasac flow velocities. Three patients with sealed endoleaks had Doppler velocities of 200 cm/s or greater. However, the diameter of the inferior mesenteric artery in these patients was 4 mm or less with no visualized lumbar arteries before surgery. Aneurysm diameter(-4.6 +/- 5.6 mm) and volume (-0.9 +/- 45.2 mL) decreased in patients with sealed endoleaks. Aneurysm diameter (1.8 +/- 4.9 mm) and volume (18.5 +/- 33.9 mL) increased slightly in patients with persistent endoleaks (P <.05). No ruptures or conversions occurred in any patient. Secondary interventions to treat type II endoleaks were unsuccessful in six of 16 patients (38%) with persistent endoleaks. CONCLUSION: Intrasac Doppler velocities can be used to predict whether a type II endoleak will spontaneously seal. High-velocity type II endoleaks are related to preoperative large branch vessel diameter and number and are resistant to endovascular treatment.

Aortic Aneurysm, Abdominal↗

Determination of known exhalation valve damage using a negative pressure user seal check method on full facepiece respirators.

A negative pressure user seal check (NPUSC) method was evaluated for its ability to adequately detect known exhalation valve leakage into a respirator. Three valves with different types of damage were included. Twenty-six test subjects, wearing full facepiece respirators, were asked to perform a NPUSC. Their responses as to whether they passed or failed the user seal check were compared to fit testing results from two quantitative fit test methods: ambient aerosol and controlled negative pressure. In addition, equipment developed at the University of Cincinnati was used to measure in-mask pressures that are generated during the performance of NPUSCs. This technique was employed to assess the ability of respirator wearers to properly conduct user seal checks. The data were analyzed to determine if the user seal check procedure is an effective method for detecting known exhalation valve damage. All test subjects reported passing the user seal check with the undamaged valve. With the warped valve installed, 95 percent of test subjects reported passing the user seal check. With the slit valve installed, 73 percent of test subjects reported passing. With the dirty valve installed, 65 percent reported passing. All fit factors, measured with the damaged valves, were below the Occupational Safety and Health Administration-recognized pass/fail criteria except one fit test with the respirator equipped with the slit valve. Results from the in-mask pressure measurements confirmed whether or not the subject properly conducted a user seal check, but did not detect respirator leakage. In conclusion, the performance of a NPUSC rarely helped to identify damaged exhalation valves. These results support the need for respirator inspection prior to donning with periodic fit testing and the performance of user seal checks as necessary components of an adequate respiratory protection program.

Equipment Failure↗

Ergonomics and safety of manual bag sealing.

A variety of seals is used to close bags. Each seal has advantages and disadvantages. For shop assistants sealing bags could be a repetitive physically demanding action. Opening and closing the bags again can cause some discomfort or annoyance for consumers. Besides, it is an activity which can endanger safety, i.e., knives being used in opening, children swallowing the systems of sealing. To prevent these problems a new sealing system was developed. In this paper the opinion of shop assistants, consumers and experts on several bag sealing systems was studied. It appeared that for sealing plastic bags, adhesive tape with paper is the best out of 4 systems, closely followed by adhesive tape. It is discussed that for the elderly, there is still room for improvement in opening bag seals.

Adolescent↗

Evaluation of a vessel sealing system, bipolar electrosurgery, harmonic scalpel, titanium clips, endoscopic gastrointestinal anastomosis vascular staples and sutures for arterial and venous ligation in a porcine model.

PURPOSE: We assessed the usefulness of the LigaSure (Valleylab, Boulder, Colorado) vessel sealing system for vascular control during laparoscopic surgery and compared it with other available hemostatic modalities. MATERIALS AND METHODS: A total of 31 domestic pigs were divided into 5 groups. In groups 1 and 2 the vessel sealing system was compared with titanium clips and Endo-GIA (United States Surgical, Stamford, Connecticut) staples. In group 3 the vessel sealing system was compared with standard Klepinger (Karl Storz, Culver City, California) bipolar forceps. In group 4 the harmonic scalpel and Trimax (United States Surgical) bipolar forceps were compared. In group 5 in vivo laparoscopic application of the vessel sealing system was evaluated. RESULTS: The 5 mm. laparoscopic vessel sealing system sealed arteries up to 6 mm. and veins up to 12 mm. in diameter at supraphysiological bursting pressure. We evaluated 13 arteries with a diameter of 6 mm. or less at a mean bursting pressure of 662 mm. Hg (range 363 to 1,985) and 11 veins with a diameter of 12 mm. or less with a mean bursting pressure of 233 mm. Hg (range 63 to 440). Collateral tissue damage extended 1 to 3 mm. from the application site. Standard bipolar energy with Klepinger and Trimax forceps was less reliable and in some cases vessel sealing could not be accurately assessed before vessel division. Collateral tissue injury was 1 to 6 mm. The harmonic scalpel did not reliably seal vessels larger than 3 mm. but resulted in the least acute collateral tissue injury of 0 to 1 mm. CONCLUSIONS: In the porcine model the LigaSure system is a viable option for laparoscopic management of arteries up to 6 mm. and veins up to 12 mm. in diameter.

Anastomosis, Surgical↗

Lip seal study of Japanese adults with malocclusion.

The purpose of this study to clarify the factors an effecting lip seal in Japanese adults with malocclusion. Sixty-three malocclusion patients aged 20 to 27 years were randomly selected and compared with fourteen normal occlusion controls aged 22 to 26 years old. The subjects were divided into a good seal group and a poor lip seal group by observing the distance between the upper and lower lip at rest. Results of this adult study were as follows; There were no poor lip seals in normal occlusion subjects. Significant differences were observed for tongue thrust (p < 0.05) and mouth breathing (p < 0.05) between the good lip seal group and poor lip seal group of malocclusion subjects. Adults with poor lip seal should be treated for their malocclusion prior to be other functional approaches to improving their lip seal.

Adult↗

[Survey of epoxidized soybean oil in cap sealing for bottled foods].

Epoxidized soybean oil (ESBO) was surveyed in the 103 samples of cap sealing for bottled foods on the Japanese market. Most of the sealings were made of polyvinyl chloride, while a few were made of polyethylene or acrylic resin. All the sealings contained ESBO in the range of 0.006-42.4%. Sealings for baby food, jam, etc. contained higher levels of ESBO, though those for beverages contained lower levels. Sealings in lug caps and press-on twist caps contained higher levels of ESBO, though that in pilfer-proof caps contained lower levels. Some sealings in screw caps and lug caps also contained other plasticizers, for example, di-2-ethylhexyl phthalate and diisononyl phthalate, and their ESBO contents were 1/10 of those in sealings containing only ESBO. In this survey, ESBO was the most common plasticizer in cap sealing resin for bottled foods on the Japanese market.

Diethylhexyl Phthalate↗

Identity concept formation during visual multiple-choice matching in a harbor seal (Phoca vitulina).

Identity concept formation was tested in a harbor seal using a visual multiple-choice matching-to-sample task. The seal was first trained on a two-alternative matching task. After criterion (> or =80% correct choices in two successive sessions) was reached with two sets of two stimuli (Figure 3, Blocks A and B), stimulus sets were enlarged to six objects (Blocks C-G). After the seal reached criterion immediately with two successive sets (Blocks F and G), multiple-choice matching was introduced, first using stimulus sets of four familiar objects (Blocks H-M). After the seal reached the criterion immediately with two successive sets (Blocks L and M), completely new objects were used in two further stimulus sets (Blocks N and O). The seal immediately applied the matching rule in all four sessions (> or =80% correct choices). In two further sessions with problems composed of all 38 familiar stimuli, the seal again reached the criterion (Block P). In the final, transfer session, 20 new problems were composed of 80 unknown stimuli (Block Q). The seal immediately applied the matching rule in these one-trial tests, showing that harbor seals can conceptualize complex visual information.

Animals↗

A study on the use of photopolymer reflex plate in the forgery of Chinese seals

This study compares the identifying characteristics between the impressions made with original Chinese seals and photopolymer replicate seals, and between the impressions made with two photopolymer replicate seals that originate from one single negative. Various seal materials common to the Chinese community such as cow's horns and ivory are employed. Other than the common factors such as different incident angle upon imprinting or different degree of inking that constitute the natural variation in impressions, the physical changes of the seal materials with temperature will be considered. This study concludes that photopolymer replicate seal impressions can be differentiated from the originals in respect to print density and stroke morphology, but it is very difficult to differentiate between two photopolymer replicate seal impressions with the same origin. This study also proposes a simple method for the examination of forged Chinese seal impressions.

Journal Article↗

Extent and mechanism of sealing in transected giant axons of squid and earthworms.

Transected axons are often assumed to seal at their cut ends by the formation of continuous membrane barriers that allow for the restoration of function in the axonal stumps. We have used several electrophysiological measures (membrane potential, input resistance, injury current density) and several morphological measures (phase-contrast, video-enhanced differential interference contrast, light, and electron microscopies) of living and fixed material to assess the extent and mechanism of sealing within hours after transecting giant axons of squid (Loligo pealei and Sepioteuthis lessoniana) and earthworms (Lumbricus terrestris). Our electrophysiological data suggest that the proximal and distal ends of transected squid giant axons do not completely seal within 2.5 hr in physiological saline. In contrast, the same set of measures suggest that proximal and distal ends of transected earthworm giant axons seal within 1 hr in physiological saline. Our morphological data show that the cut ends of both squid and earthworm axons constrict, but that a 20-70-microns-diameter opening always remains at the cut end that is filled with vesicles. Axonal transection induces the formation of vesicles that are observed in the axoplasm within minutes in standard salines and that rapidly migrate to the cut ends. These injury-induced vesicles are loosely packed near the cut ends of squid giant axons, which do not functionally seal within 2.5 hr of transection. In contrast, vesicles formed a tightly packed plug at the cut ends of earthworm medial giant axons, which do functionally seal within 1 hr of transection in physiological saline. Since we detect no single continuous membrane that spans the cut end, sealing does not appear to occur by the fusion of constricted axolemmal membrane or the formation of a membranous partition at the cut end. Rather, our data are consistent with the hypothesis that a tightly packed vesicular plug is responsible for sealing of earthworm giant axons.

Animals↗