Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Radiotherapy, Intensity-Modulated”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14Linked to original sources

Dynamic beam modulation by using a single computer-controlled absorber.

The authors have developed an apparatus able to generate ID intensity-modulated beams, using only one moving absorber within the irradiation field. A procedure for deriving optimized absorber-speed profiles in order to produce the desired fluence/dose profiles has been suggested. Experimental tests show that the system should be sufficiently reliable in reproducing modulated beam profiles of different shape: expected relative doses against measured relative doses have been found to be in agreement in a number of situations within 3% using a nonfocused device. A better agreement should be expected using a focused apparatus (which is currently being developed). Beam modulation by single absorber cannot modulate the beam fluence in any was one wishes, due to physical constraints, which depend on the absorber and field widths and on the shape of the desired fluence profile. However, the authors show that this simple and low-cost tool could offer, with a sufficient degree of accuracy, the possibility of modulating the beam fluence with a high degree of versatility. In particular, a procedure or performing tissue-missing compensation by single-absorber dynamic beam modulation is suggested. Moreover, 'strongly' modulated beam profiles can be created, showing that this simple technique could also have some interesting applications in the field of conformal radiotherapy by non-uniform dose delivery.

Algorithms↗

A method to study the characteristics of 3D dose distributions created by superposition of many intensity-modulated beams delivered via a slit aperture with multiple absorbing vanes.

Highly conformal dose distributions can be created by the superposition of many radiation fields from different directions, each with its intensity spatially modulated by the method known as tomotherapy. At the planning stage, the intensity of radiation of each beam element (or bixel) is determined by working out the effect of superposing the radiation through all bixels with the elemental dose distribution specified as that from a single bixel with all its neighbours closed (the 'independent-vane' (IV) model). However, at treatment-delivery stage, neighbouring bixels may not be closed. Instead the slit beam is delivered with parts of the beam closed for different periods of time to create the intensity modulation. As a result, the 3D dose distribution actually delivered will differ from that determined at the planning stage if the elemental beams do not obey the superposition principle. The purpose of this paper is to present a method to investigate and quantify the relation between planned and delivered 3D dose distributions. Two modes of inverse planning have been performed: (i) with a fit to the measured elemental dose distribution and (ii) with a 'stretched fit' obeying the superposition principle as in the PEACOCK 3D planning system. The actual delivery has been modelled as a series of component deliveries (CDs). The algorithm for determining the component intensities and the appropriate collimation conditions is specified. The elemental beam from the NOMOS MIMiC collimator is too narrow to obey the superposition principle although it can be 'stretched' and fitted to a superposition function. Hence there are differences between the IV plans made using modes (i) and (ii) and the raw and the stretched elemental beam, and also differences with CD delivery. This study shows that the differences between IV and CD dose distributions are smaller for mode (ii) inverse planning than for mode (i), somewhat justifying the way planning is done within PEACOCK. Using a stretched elemental beam is a useful adjustment to improve the accuracy of inverse planning but the 3D dose distribution actually delivered will display characteristics of the collimation.

Humans↗

The effects of intra-fraction organ motion on the delivery of dynamic intensity modulation.

Computer-optimized treatment plans, aimed to enhance tumour control and reduce normal tissue complication, generally require non-uniform beam intensities. One of the techniques for delivering intensity-modulated beams is the use of dynamic multileaf collimation, where the beam aperture moves and the field shape changes during irradiation. When intensity-modulated beams are delivered with dynamic collimation, the problem of intra-fraction organ motion can cause distortions to the desired beam intensities. Unlike static field treatments, where intra-fraction organ motion only affects the boundaries creating broad dose penumbra, the interplay of the movement of the beam aperture and the movement of the patient anatomy can create 'hot' and 'cold' spots throughout the field. The mechanism for creating these effects is not well understood. This paper provides a simple analytical model which illustrates the fundamental mechanism for creating the dosimetric variations in the target when both the beam aperture and the target move during irradiation. Numerical analysis was carried out which calculates the cumulative primary photon fluence, or beam intensity, received by each point in the target, for a given pattern of motion. The results show that, for clinically realistic parameters, the magnitude of intensity variations in the target can be greater than 100% of the desired beam intensity. The magnitude of the photon intensity variations is strongly dependent on the speed of the beam aperture relative to the speed of the target motion, and the width of the scanning beam relative to the amplitude of target motion. The effects of fractionation as well as methods of minimizing and eliminating the dosimetric effects of intra-fraction organ motion are discussed.

Biophysical Phenomena↗

Configuration options for intensity-modulated radiation therapy using multiple static fields shaped by a multileaf collimator.

One-dimensional (1D) intensity-modulated beams (IMBs) can be generated by multiple static fields (MSFs) created by a multileaf collimator (MLC) with the radiation switched off between field re-settings (Bortfeld-Boyer method). Each component irradiation is of equal fluence. This paper presents and analyses the formulae for the number of physically allowed combinations of leaf settings which generate any given IMB. The formulae are general to an IMB with any number of local minima and extend from the well-known N! formula for a single-peaked IMB with N left-leaf (L-leaf) and N right-leaf (R-leaf) positions. A 'combination' is a set of N L-leaf and R-leaf pairings. A 'physically allowed combination' is one in which no L-leaf is paired with an R-leaf to its left. The physically allowed combinations are grouped by specific properties into classes in which the well-known techniques of 'leaf-sweep' and 'close-in' are just two members. Consideration of these properties leads to a new suggestion of the 'forced-baseline' configuration in which the first intensity increment is delivered for the full field width and there remain choices concerning the delivery of the rest of the IMB within which two different possibilities are 'one-out-of-sync leaf-sweep' and 'minimum leaf travel'. The extension to 2D is briefly introduced.

Models, Theoretical↗

Configuration options for intensity-modulated radiation therapy using multiple static fields shaped by a multileaf collimator. II: constraints and limitations on 2D modulation.

This paper addresses the technique of using multiple static multileaf-collimator-shaped field components to create a two-dimensional intensity-modulated beam (2D IMB). It addresses the physical constraints on the problem of determining the optimum field-component leaf configurations under the circumstances that (i) the static field components are shaped by leaves alone and (ii) the 2D intensity distribution is delivered by exactly N field components when there are N rising-intensity equal-fluence increments in the 1D channel containing the maximum fluence in the 2D IMB. This corresponds to the least inefficient delivery. In general it is noted that an optimum solution (set of field-component leaf configurations) with zero tongue-and-groove underdose may not exist (depending on the distribution) and an exhaustive search for the set of leaf configurations with the minimum tongue-and-groove underdose is impossible for realistically sized problems. Against this background iterative methods to examine a limited search space are shown to yield an optimum solution with zero tongue-and-groove underdose for certain intensity distributions. These searches are not robust and can be defeated. The problem of finding an optimum solution may be generally insoluble for some 2D IMBs under the conditions (i) and (ii). If, however, a larger number of field components is permitted and/or the accelerator jaws may also be used, in addition to the multileaves, then an optimum solution with zero tongue-and-groove underdose can always be found with lower efficiency.

Biophysical Phenomena↗

A new concept of multileaf collimator (the shuttling MLC)--an interpreter for high-efficiency IMRT.

This paper proposes a radically new concept for a multileaf collimator for a photon linear accelerator for delivering IMRT with high monitor-unit efficiency. The concept is to consider each M (rows) x N (columns) two-dimensional intensity-modulated beam (2D IMB) as a set of N/2 M (rows) x 2 (columns) areas of modulation. Each area is then delivered by a set of M shuttling attenuating elements (called here the shuttling MLC) with a very high monitor-unit efficiency. The elements shuttle between each of the two columns comprising the M x 2 area and the modulation is provided by the variation in dwell time of the elements. The principles of this shuttling multileaf collimator are discussed and examples illustrating its operation are given. The main achievement reported in this paper is the development and robust testing of an interpreter which describes the position-time course of movement of the elements as a function of monitor units. This interpreter fully accounts for leakage transmission through the elements. It completely avoids the across-the-rows tongue-and-groove underdose. A large number of ID and 2D IMBs have been subjected to this interpreter and it is shown that for random patterns of fluence the SMLC is more monitor-unit efficient than the Bortfeld-Boyer technique (the most efficient with a conventional MLC) when the modulation is highly structured.

Algorithms↗

Dynamic splitting of large intensity-modulated fields.

The aims of this paper are to describe a method of splitting large intensity-modulated fields that cannot be delivered as a single field and to verify the accuracy of our method. Some multi-leaf collimators may be operated in the dynamic mode to deliver intensity-modulated radiation treatments (IMRT) using the 'sliding window' technique. In this technique each pair of leaves sweeps over the treatment field while the beam is on. However, there are limitations on the width of the field that can be treated due to the limited length of the leaves. For instance, the leaf length of the Varian MLC is 14.5 cm. Since each leaf pair must travel from the left boundary to the right boundary of the beam aperture, the maximum width of the field aperture that can be accommodated in one sweep of leaves is also limited to 14.5 cm, in fact to a slightly smaller value. It has been shown that IMRT is more efficient when used to plan and deliver the large and boost fields simultaneously. In such situations, the fields must be large enough to cover simultaneously the volumes of the gross tumour, microscopic disease and electively treated regions. Such field sizes are often larger than 14.5 cm wide. In this paper, we present a dynamic 'feathering' technique to split the large intensity-modulated fields into smaller fields. In this technique, the component beams overlap each other by a small amount, and the intensity in the overlap region gradually decreases for one field component and increases for the other. The sum of intensities remains the same as for the original field. This method eliminates the field matching problems associated with the conventional step 'break' for static fields. The splitting process is integrated into the IMRT treatment procedure and the entire planning process is automated. Comparison of dose distributions calculated and measured in a phantom showed good agreement. Such a method can be applied to the 'step and shoot' technique as well. IMRT fields of widths up to 25 cm can be delivered by splitting only once, which is adequate for most treatments.

Algorithms↗

Intensity modulated arc therapy (IMAT) with centrally blocked rotational fields.

A new technique for intensity-modulated beam (IMB) delivery that combines the features of intensity modulated arc therapy (IMAT) with the use of 'classical blocks' is proposed. The role of the blocks is to realize the high-gradient modulation of the intensity profile corresponding to the region to be protected within the body contour, while the MLC leaves or the secondary collimator defines the rest of the field and delivers intensity-modulated multiple rotational segments. The centrally blocked radiation fields are applied sequentially, in several rotations. Each rotation of the gantry is responsible for delivering one segment of the optimal intensity profile. The new IMAT technique is applied for a treatment geometry represented by an annular target volume centrally located within a circular body contour. The annulus encompasses a circular critical structure, which is to be protected. The beam opening and corresponding weight of each segment are determined in two ways. The first method applies a linear optimization algorithm to precalculated centrally blocked radial dose profiles. These radial profiles are calculated for a set of beam openings, ranging from the largest field that covers the whole planning target volume (PTV) to the smallest, which is 1 cm larger than the width of the central block. The optimization is subjected to dose homogeneity constraints imposed on a linear combination of these profiles and finally delivers the dimensions and weights of the rotational beams to be used in combination. The second method decomposes into several subfields the fluence profile of a rotational beam known to deliver a constant dose level to PTV. This fluence profile is determined by using the analytical method proposed by Brahme for the case of the annular PTV and the concentric organ at risk (OAR). The proper segmentation of this intensity profile provides the field sizes and corresponding weights of the subfields to be used in combination. Both methods show that for this particular treatment geometry, three to seven segments are sufficient to cover the PTV with the 95% dose level and to keep the dose level to the central critical structure under 30% of the maximum dose. These results were verified by experimentally delivering the calculated segments to radiotherapy verification films sandwiched between two cylindrical pieces of a pressed-wood phantom. The total beam time for a three-field irradiation was 77 s. The predicted and experimental dose profiles along the radius of the phantom agreed to within 5%. Generalization of this technique to real-patient treatment geometry and advantages over other conformal radiotherapy techniques are also discussed.

Algorithms↗

Concepts for shuttling multileaf collimators for intensity-modulated radiation therapy.

Shuttling multileaf collimators (SMLCs) can increase the MU efficiency of intensity-modulated radiation therapy compared with the multiple-static-field (MSF-MLC) technique or dynamic MLC (DMLC) technique with conventional MLCs. In a previous paper (Phys. Med. Biol. 45 3343-58) a particular SMLC was shown, for highly modulated intensity distributions, to increase the MU efficiency compared with the MSF-MLC technique. In this companion paper, two new arrangements similar to that described in the earlier paper, but with less mechanical complexity, are shown to be constructionally simpler but less MU efficient. Additionally another new concept of SMLC is shown which also increases the MU efficiency compared with the MSF-MLC technique and often improves the MU efficiency compared with the previously reported SMLC for highly modulated intensity distributions. It also leads to zero tongue-and-groove underdose in the direction orthogonal to that of the shuttling elements (so-called across-the-rows).

Equipment Design↗

A method of simulating dynamic multileaf collimators using Monte Carlo techniques for intensity-modulated radiation therapy.

A method of modelling the dynamic motion of multileaf collimators (MLCs) for intensity-modulated radiation therapy (IMRT) was developed and implemented into the Monte Carlo simulation. The simulation of the dynamic MLCs (DMLCs) was based on randomizing leaf positions during a simulation so that the number of particle histories being simulated for each possible leaf position was proportional to the monitor units delivered to that position. This approach was incorporated into an EGS4 Monte Carlo program, and was evaluated in simulating the DMLCs for Varian accelerators (Varian Medical Systems, Palo Alto. CA, USA). The MU index of each segment, which was specified in the DMLC-control data, was used to compute the cumulative probability distribution function (CPDF) for the leaf positions. This CPDF was then used to sample the leaf positions during a real-time simulation, which allowed for either the step-shoot or sweeping-leaf motion in the beam delivery. Dose intensity maps for IMRT fields were computed using the above Monte Carlo method, with its accuracy verified by film measurements. The DMLC simulation improved the operational efficiency by eliminating the need to simulate multiple segments individually. More importantly, the dynamic motion of the leaves could be simulated more faithfully by using the above leaf-position sampling technique in the Monte Carlo simulation.

Biophysical Phenomena↗

Computer-assisted selection of coplanar beam orientations in intensity-modulated radiation therapy.

In intensity-modulated radiation therapy (IMRT), the incident beam orientations are often determined by a trial and error search. The conventional beam's-eye view (BEV) tool becomes less helpful in IMRT because it is frequently required that beams go through organs at risk (OARs) in order to achieve a compromise between the dosimetric objectives of the planning target volume (PTV) and the OARs. In this paper, we report a beam's-eye view dosimetrics (BEVD) technique to assist in the selection of beam orientations in IMRT. In our method, each beam portal is divided into a grid of beamlets. A score function is introduced to measure the 'goodness' of each beamlet at a given gantry angle. The score is determined by the maximum PTV dose deliverable by the beamlet without exceeding the tolerance doses of the OARs and normal tissue located in the path of the beamlet. The overall score of the gantry angle is given by a sum of the scores of all beamlets. For a given patient. the score function is evaluated for each possible beam orientation. The directions with the highest scores are then selected as the candidates for beam placement. This procedure is similar to the BEV approach used in conventional radiation therapy, except that the evaluation by a human is replaced by a score function to take into account the intensity modulation. This technique allows one to select beam orientations without the excessive computing overhead of computer optimization of beam orientation. It also provides useful insight into the problem of selection of beam orientation and is especially valuable for complicated cases where the PTV is surrounded by several sensitive structures and where it is difficult to select a set of 'good' beam orientations. Several two-dimensional (2D) model cases were used to test the proposed technique. The plans obtained using the BEVD-selected beam orientations were compared with the plans obtained using equiangular spaced beams. For all the model cases investigated, the use of BEVD-selected beam orientations improved the dose distributions significantly. These examples indicate that the technique has considerable potential for simplifying the IMRT treatment planning process and allows for better utilization of the technical capacity of IMRT.

Humans↗

Dependence of linac output on the switch rate of an intensity-modulated tomotherapy collimator.

The electro-mechanical, multivane intensity modulated collimator ("MIMiC") slit collimator with 40 vanes has been applied in the delivery of inversely planned sequential tomotherapy to over 4,000 patients. The collimator is binary in that each vane switches between fully open or closed status. Resulting beamlet patterns provide the intensity distributions imparting dose to the patient. The bouncing and damping of vanes at the two ends of their travel cause transient dose perturbations near and at the borders of the treatment field. These perturbations are not explicitly modeled by the planning system. Clinical beamlet profiles and output factors may then differ from those in the planning system and as a function of the vane switch period. A mechanical model of vane switching was developed to describe this dependency. Dose output and distribution of seven simple vane patterns with different switch times were measured with ionization chambers and radiographic films in polystyrene and anthropomorphic phantoms. Linac output dependence on switch time relative to vane open time was determined for four intensity modulated radiotherapy (IMRT) patients from measurements of an ionization chamber embedded in a cylindrical polystyrene phantom. Results demonstrate output dependence on switch time and, accordingly, on the servo mechanism for monitor units, arc length, dose rate, and gantry speed. In conclusion, the output dependence borders on clinical significance-improvements to collimator, dose calculation, commissioning, and quality assurance (QA) are suggested.

Humans↗

Implementing multiple static field delivery for intensity modulated beams.

A clinically oriented two-dimensional intensity-modulated beam delivery method is implemented using multiple static segmented fields, i.e., the "step-and-shoot" approach. Starting with a desired al" intensity distribution, it creates a multiple-level intensity approximation, and then constructs a sequence of segmented fields to deliver the multiple-level intensities using multileaf collimator (MLC) and independent backup jaws. The approach starts with a simple grouping of all the nonzero intensity values into a minimum number of clusters for a user specified deviation tolerance for the ideal plan. The k-means clustering algorithm is then employed to find the optimal levels of intensity that minimize the discrepancies between the ideal and the approximated intensities, without violating the user specified deviation tolerance. The multiple-level intensities are then decomposed into a sequence of machine deliverable segments. Apart from the first segment for each gantry angle, all the other segments are arranged to minimize the total travel distance of the leaves. The first segment covers the entire irradiated area and is used for treatment verification by electronic portal imaging. The implementation issues due to the physical constraints of the MLCs are also addressed.

Algorithms↗

Minimizing the number of segments in a delivery sequence for intensity-modulated radiation therapy with a multileaf collimator.

This paper proposes a sequencing algorithm for intensity-modulated radiation therapy with a multileaf collimator in the static mode. The algorithm aims to minimize the number of segments in a delivery sequence. For a machine with a long verification and recording overhead time (e.g., 15 s per segment), minimizing the number of segments is equivalent to minimizing the delivery time. The proposed new algorithm is based on checking numerous candidates for a segment and selecting the candidate that results in a residual intensity matrix with the least complexity. When there is more than one candidate resulting in the same complexity, the candidate with the largest size is selected. The complexity of an intensity matrix is measured in the new algorithm in terms of the number of segments in the delivery sequence obtained by using a published algorithm. The beam delivery efficiency of the proposed algorithm and the influence of different published algorithms used to calculate the complexity of an intensity matrix were tested with clinical intensity-modulated beams. The results show that no matter which published algorithm is used to calculate the complexity of an intensity matrix, the sequence generated by the algorithm proposed here is always more efficient than that generated by the published algorithm itself. The results also show that the algorithm used to calculate the complexity of an intensity matrix affects the efficiency of beam delivery. The delivery sequences are frequently most efficient when the algorithm of Bortfeld et al. is used to calculate the complexity of an intensity matrix. Because no single variation is most efficient for all beams tested, we suggest implementing multiple variations of our algorithm.

Algorithms↗

Smoothing intensity-modulated beam profiles to improve the efficiency of delivery.

Intensity-modulated beam profiles are generated by an inverse planning or optimization algorithm, a process that, being computationally complex and intensive, is inherently susceptible to noise and numerical artifacts. These artifacts make delivery of the beams more difficult, oftentimes for little, if any, observable improvement in the dose distributions. In this work we examine two approaches for smoothing the beam profiles. The first approach is to smooth the beam profiles subsequent to each iteration in the optimization process (method A). The second approach is to include a term within the objective function that specifies the smoothness of the profiles as an optimization criterion (method B). The two methods were applied to a phantom study as well as three clinical sites: paraspinal, nasopharynx, and prostate. For the paraspinal and nasopharynx cases, which have critical organs with low tolerance doses in close proximity, method B produced sharper dose gradients, better target dose homogeneity, and more critical organ sparing. In the less demanding prostate case, the two methods give similar results. In addition, method B is more efficient during optimization, requiring fewer iterations, but less efficient during DMLC delivery, requiring a longer beam-on time.

Algorithms↗

Verification of dynamic intensity-modulated beam deliveries in canine subjects.

Our objective in this work was to assess the precision and degree of accuracy with which intensity modulated radiation therapy (IMRT) can deliver highly localized dose distributions to tumors near critical structures using the dynamic sliding window technique. Measurements of dose distribution were performed both in vivo and in vitro using a combination of dosimeters [thermoluminescent dosimeters (TLD's), films, and diodes]. In vivo measurements were performed in two groups of purpose-bred dogs: one receiving four-field three-dimensional (3D) conformal treatment and the other receiving IMRT. The algorithms used in the inverse planning process included the Macro Pencil Beam (MPB) model and Projections onto Convex Sets (POCS). Single beam measurements were performed in phantoms to verify the accuracy of monitor unit settings required for delivering the desired doses. The composite doses from the delivery of the seven beam intensity modulated plans were measured in phantoms and cadavers, Biological end points (spinal cord toxicity and neurologic deficits due to irradiation) were evaluated at the end of one year to determine the spatial accuracy of the IMRT treatments over a fractionated course in live subjects. Results in single beam measurements were used at first to improve the dose calculation and translation algorithms. Results of the measurements for the delivery of all seven beams in phantoms confirmed that the system was capable of accurate spatial and dosimetric IMRT delivery. The in vivo results showed dramatic differences between control and IMRT-treated dogs, with the IMRT group showing no adverse effects and the control animals showing severe spinal cord injuries due to irradiation. The measurements presented in this paper have helped to verify the successful and accurate delivery of IMRT in a clinically related model using the University of Washington Medical Center (UWMC) system.

Algorithms↗

Delivery of intensity-modulated radiation therapy with a conventional multileaf collimator: comparison of dynamic and segmental methods.

Intensity-modulated radiation therapy (IMRT) can be delivered with a conventional multileaf collimator (MLC), either in dynamic mode (DMLC) or in segmental mode (SMLC, also known as "step-and-shoot"). The advantage of DMLC is its ability to deliver the desired intensity profile produced by inverse planning with a high degree of fidelity. The SMLC method, on the other hand, resembles treatment with multiple static fields, and can be more easily verified. However, the use of SMLC requires that the desired profile be approximated by discrete levels of intensity, which may lead to degradation in the delivered dose distribution. Clearly, the results of SMLC delivery depend on the number of levels and the spatial resolution of the intensity distribution. In this work, we compare the DMLC method and the SMLC method employing different numbers of levels and different spatial resolutions. Three disease sites were studied: prostate, nasopharynx, and breast, with three cases for each. In general, a 5- to 10-level SMLC plan produced results comparable to that from a DMLC plan. The target coverage is improved by increasing the number of levels while critical organs are better protected with finer spatial resolutions. The beam-on-time (MUs) requirement for SMLC was approximately 20% less than DMLC, but the delivery time (in minutes) was about twice as long. Thus, the choice depends on many factors including machine capability, quality assurance, target coverage, critical organ protection, beam-on-time, delivery time, and other clinical considerations.

Breast Neoplasms↗

The optimum intensities for multiple static multileaf collimator field compensation.

A method of determining the optimum beam intensities for compensation using multiple static multileaf collimator fields is presented. In this method a histogram of the number of beam pixels against beam intensity is generated for the intensity-modulated beam (IMB). The intensity of each beam to be used is chosen to minimize the mean square deviation between each bin in the histogram and the closest beam intensity. This method has been applied to sample IMBs possessing one maximum and two maxima. For both cases, the use of uniform beam intensity increments is shown to be close to optimal. In the case with two maxima, the efficacy of irradiating both peaks simultaneously, rather than separately, has been studied and shown to be of potential benefit. The optimum intensities for an IMB for breast radiotherapy are also presented.

Humans↗