Intrapartum fetal pulse oximetry. Part 2: Clinical application.

UNLABELLED: Part II continues by discussing the clinical application of fetal pulse oximetry in intrapartum fetal surveillance as reviewed in the literature. It profiles the predictive ability of fetal pulse oximetry and its correlation with conventional methods of fetal monitoring. In addition, an account is made of its limitations, safety, and acceptability in clinical practice. TARGET AUDIENCE: Obstetricians & Gynecologists, Family Physicians LEARNING OBJECTIVES: After completion of this article, the reader will be able to describe the predictive abilities of fetal pulse oximetry and its correlation with conventional methods of fetal monitoring, to define the critical threshold of fetal oxygen saturation, and to summarize the safety of fetal pulse oximetry.

Equipment Safety↗

Effect of pregnancy on maternal oxygen saturation values: use of reflectance pulse oximetry during pregnancy.

Our objective was to evaluate the usefulness of pulse oximetry monitoring in a large population of pregnant patients. We designed our study to measure pulse oximetry saturation in a cross section of 952 obstetric inpatients and outpatients. A group of 366 patients identified as normal were compared with abnormal subgroups. A subgroup of 64 patients with saturation measurements less than 96% were further evaluated. Our results indicated that oxygen saturation values did not change appreciably during the course of pregnancy in normal patients. Hypoxemia (saturation measurement less than 96%) was associated with smoking, and hypoxemia with preterm labor occurred more frequently in patients who smoked. Obesity and magnesium sulfate use appeared to be synergistic in the presence of hypoxemia. We concluded that the routine use of pulse oximetry during pregnancy may not be justified. Smoking, obesity, and magnesium sulfate use have some effect on oximetry in pregnant patients.

Adult↗

Nocturnal oximetry: utility in the respiratory management of amyotrophic lateral sclerosis.

OBJECTIVE: Current recommendations are to institute nocturnal nasal ventilation for amyotrophic lateral sclerosis patients with a forced vital capacity (FVC) of <50% of predicted normal. The purpose of this study was to determine whether this is appropriate. DESIGN: A total of 87 nocturnal oximetry evaluations were performed on 78 consecutive amyotrophic lateral sclerosis patients symptomatic for sleep-disordered breathing. Nocturnal oximetry measurements were compared for those with FVC >50% vs. those with FVC of <50% of normal. FVC was measured sitting and supine. RESULTS: A considerable number of these symptomatic patients manifested evidence of nocturnal hypoxemia as measured by oximetry. However, there was no significant difference between patients with sitting percentage-predicted FVC above and below 50% predicted in minimum oxygen saturation, mean oxygen saturation, percentage of time spent with oxygen saturation of <88%, and number of events per hour. There was no significant difference between patients with supine percentage-predicted FVC above and below 50% predicted in minimum oxygen saturation, mean oxygen saturation, percentage of time spent with oxygen saturation of <88%, and number of events per hour. CONCLUSION: The recommendation that FVC be <50% of normal is inappropriate for justifying introduction of nocturnal nasal ventilation. Many patients are symptomatic at higher FVC and manifest evidence of nocturnal hypoxemia. Nocturnal oximetry adds additional practical information for justifying earlier respiratory intervention for symptomatic patients.

Amyotrophic Lateral Sclerosis↗

Reflectance pulse oximetry measurements from the retinal fundus.

Conventional transmission pulse oximetry is a noninvasive technique for the continuous monitoring of arterial oxygen saturation (SaO2) from peripheral vascular beds such as the finger tip or earlobe. In this paper we propose to exploit the unique transparency of the ocular media to make reflectance pulse oximetry measurements on the retinal fundus. This technique potentially offers significant advantages over conventional pulse oximetry, primarily the ability to monitor cerebral, as opposed to peripheral, oxygen saturation. We have developed an in vitro system to stimulate the retinal circulation and ocular optics. This system consists of a flexible cuvette located in a model eye and an extracorporeal blood circuit to stimulate arterial blood flow. The system was used to investigate the relationship between SaO2 and the R/IR ratio in reflectance pulse oximetry. To enable in vivo measurements to be made, we also modified a standard haptic contact lens to hold the pulse oximeter probe in front of the pupil. In a preliminary study, the lens was fitted to an awake volunteer and cardiac-synchronous signals were detected by the retinal pulse oximeter.

Contact Lenses↗

Pulse oximetry theory and calibration for low saturations.

Pulse oximetry is a widely used technique in biomedical optics, but currently available pulse oximeters rely on empirical calibration approaches, which perform poorly at low saturations. We present an exact solution for pulse oximetry and show how this can be used as the basis for the development of a semiempirical calibration approach that may be useful, especially at low saturations and variable probe geometries. This new approach was experimentally tested against traditional empirical calibration techniques on transmission pulse oximetry for monitoring of fetal sheep using a minimally invasive spiral probe. The results open the way for the development of more accurate pulse oximetry.

Animals↗

Pulse oximetry in sickle cell disease.

The place of pulse oximetry in monitoring arterial oxygen saturation in sickle cell disease has been evaluated. In four admissions of patients with sickle cell anaemia with varying degrees of arterial haemoglobin oxygen desaturation, pulse oximetry was compared with a simultaneous assessment of oxygen saturation by arterial blood gas measurement and oxygen dissociation curve (ODC) analysis. Close agreement was found between the oxygen saturation measured by pulse oximetry and that calculated from the measured arterial partial pressure of oxygen (PaO2) with reference to the patient's own ODC. Calculation of oxygen saturation by the blood gas analyser assuming a normal ODC was erroneous. Pulse oximetry is an accurate and effective non-invasive method for monitoring the arterial oxygen saturation in sickle cell disease.

Anemia, Sickle Cell↗

Overnight pulse oximetry in snoring and non-snoring children.

The effect of snoring on overnight pulse oximetry recordings in the paediatric community was investigated. A random sample of 222 children up to 10 years of age from the town of Frome, Somerset, UK, had overnight pulse oximetry performed in the home environment. The oximetry recordings obtained from 58 snoring and 164 non-snoring subjects were compared. No clinically relevant difference in oxygen saturation level could be detected between these two groups of children. In conclusion, snoring in children up to 10 years of age is common, 11% often snore. It is not associated with hypoxia as measured by overnight pulse oximetry. This would suggest that surgical intervention for the symptom of snoring alone is not indicated.

Child↗

Early detection of inadvertent oesophageal intubation: pulse oximetry vs. capnography.

The aim of our retrospective study was to evaluate the efficacy of routine pulse oximetry and capnometry for detection of oesophageal tube misplacement. Patients undergoing ENT interventions at our hospital are routinely monitored by ECG, arterial blood pressure by cuff, capnography, and pulse oximetry. Beat-to-beat values of Sao2 and CO2 waveform were recorded by a graphic printer connected to a microcomputer, ASA I patients were routinely preventilated with FIO2 = 0.3, and ASA II-III patients with FIO2 = 1.0. Anaesthesia was performed by junior anaesthesiologists under the close supervision of a resident. During a 16-month period, 1372 patients were anaesthetized. The records of 21 patients with accidental oesophageal tube misplacement were available for retrospective evaluation. Nine patients were preventilated with FIO2 = 0.3 (ASA I), 12 patients with FIO2 = 1.0 (ASA II-III). Rapid detection of oesophageal tube position as early as the first ventilation is possible by capnometry, because of the highly significant difference in end-tidal CO2 (0.2 +/- 0.2 vol%; tracheal intubation: 3.7 +/- 0.9 vol.%; P less than 0.0001). The present advanced pulse oximetry method does not permit differentiation between oesophageal and tracheal tube position within 30 s in patients preventilated with FIO2 = 1.0. Oesophageal misplacement was detectable within 7.5 +/- 0.9 s in patients preventilated with FIO2 = 0.3 due to a 2.1 +/- 0.8% decrease in Sao2 (P less than 0.001). Our results underscore the significance of capnometry for rapid detection of inadvertent oesophageal intubation. High-resolution pulse oximetry is a valuable supplement but not a substitute for capnometry.

Carbon Dioxide↗

Near-infrared transmittance pulse oximetry with laser diodes.

Pulse oximeters are widely used for noninvasive monitoring of oxygen saturation in arterial blood hemoglobin. We present a transmittance pulse oximetry system based on near-infrared (NIR) laser diodes (750 and 850 nm) for monitoring oxygen saturation of arterial blood hemoglobin. The pulse oximetry system is made up of the optical sensor, sensor electronics, and processing block. Also, we show experimental results obtained during the development of the whole NIR transmittance pulse oximetry system along with modifications in the sensor configuration, signal processing algorithm, and calibration procedure. Issues concerning wavelength selection and its implications for the improvement of the transmittance pulse oximetry technique are discussed. The results obtained demonstrate the proposed system's usefulness in monitoring a wide range of oxygen saturation levels.

Aged↗

Pulse oximetry in acute asthma.

The predictive value of pulse oximetry was evaluated in 100 patients who attended the emergency department with acute asthma. Oximetry after treatment with a cut off point of less than 91% had a sensitivity of 42% and specificity of 78% for unfavourable outcome, and oximetry before treatment had a sensitivity of 36% and a specificity of 57%. Despite its low sensitivity, oximetry after treatment does seem to have a role in minimising diagnostic errors in the emergency department, but only when used in conjunction with clinical assessment.

Acute Disease↗

Pulse oximetry in sickle cell disease.

Patients with sickle cell disease usually have mild hypoxaemia and their oxyhaemoglobin dissociation curve is shifted to the right. It follows that oxygen saturation in sickle cell disease should be lower than normal. Most subjects in this clinic had normal oxygen saturation by pulse oximetry, however. To improve the understanding of this paradox, arterialised capillary oxygen tension (PO2) and oxygen saturation were compared with simultaneously measured pulse oximeter saturation in 20 children with sickle cell disease. In addition, the PO2 at 50% haemoglobin saturation (P50) was compared with saturation measured by pulse oximetry in all 20 patients. It was found that saturation measured by pulse oximetry was, on the whole, similar to that calculated from the sampled blood. Individual deviations were not random, however, and were partly explained by differences in P50 values. It is concluded that pulse oximetry gives variable results in patients with sickle cell disease and should be used with caution to predict arterial saturation in this patient group.

Anemia, Sickle Cell↗

Validation of pulse oximetry during progressive normobaric hypoxia utilizing a portable chamber.

Validation of pulse oximetry in commercially available normobaric hypoxic chambers (NHC) has not been previously reported. The present study examined the validity of pulse oximetry (SpO2) against direct measurements of arterial oxygen saturation (SaO2) via co-oximetry (AVOXimeter 4000) in 13 young adults age 21.3 +/- 0.6 years. Over a period of 2.5 hrs, the inspired fraction of oxygen inside a NHC (Hypoxico, Inc.) was progressively reduced from 20.9% to 11.5%. Measurements of SaO2 at baseline and at 15, 30, 60, 90, 120, and 150 min during the hypoxic exposures were compared with SpO2 estimates of oxygen saturation (Nellcor 295) using reflectance (RS-10, temporal) and transmission (D-25, finger) sensors. Regression analysis and methods for assessing agreement (bias, b; precision, p) of SaO2 with SpO2 were similar (R2 = 0.92, 0.89; b = 0.016, -0.47; p = 2.47, 3.03; RS-10 and D-25, respectively). When SaO2 < 85%, RS-10 had greater validity than D-25 (R2 = 0.73, 0.56; b = 1.38, 1.13; p = 2.72, 4.34; RS-10 and D-25, respectively). In light of these findings, caution should be exercised when monitoring individuals with pulse oximetry during desaturation episodes below 85%. When employing frequent NHC exposures, a priori validation of SpO2 utilized to assess blood oxygen status appears warranted.

Adult↗

Severe variable decelerations and fetal pulse oximetry during the second stage of labor.

OBJECTIVES: The aim of the study was to investigate the usefulness of fetal pulse oximetry in cases of severe variable decelerations in the second stage of labor. METHODS: It is a prospective study including 58 patients. Thirty-eight patients (group A) had a normal uncomplicated labor and 20 patients (group B) developed severe variable decelerations during the second stage of labor. All patients were primiparous with normal pregnancies and had electronic fetal monitoring of labor in conjunction with fetal pulse oximetry. An estimation of fetal pH and base deficit was performed at delivery in all patients. RESULTS: There was no statistically significant difference in relation to maternal age and gestational age between the two groups. Group A patients did not delivered neonates with metabolic acidosis. Six out of 20 (group B) patients delivered neonates with a pH <7.10 despite a fetal pulse oximetry reading of >30%. CONCLUSIONS: It appears that fetal pulse oximetry is not capable of detecting pre-acidotic or acidotic fetuses during the second stage of labor in patients with severe variable decelerations and the management of such patients should be supported by fetal scalp pH when indicated or otherwise the obstetrician should expedite delivery either with assisted operative delivery or cesarean section. Fetal heart rate monitoring was introduced into clinical practice over 30 years ago. It continues to be the predominant method of intrapartum fetal surveillance despite worries about its accuracy and efficacy.

Acidosis↗

Oximetry catheters in diagnostic heart catheterization in children.

The aim of this study was to assess the performance of pediatric-size oximetry catheters in diagnostic heart catheterization. Measurements of pressures and oxygen saturations were obtained with oximetry catheters as well as with standard methods during routine heart catheterizations in 10 infants and children with congenital heart defects. Maneuverability of the oximetry catheters was comparable to that of standard Swan-Ganz catheters. Pressure tracings were damped, but mean pressures were undistorted. Oxygen saturation measurements exhibited bias and scatter. It is concluded that no advantage is obtained by the use of oximetry catheters in diagnostic heart catheterization in children and infants.

Cardiac Catheterization↗

Detection of cerebral venous desaturation by continuous jugular bulb oximetry following acute neurotrauma.

A prospective observational study was performed to assess the reliability of fibreoptic oximetric catheters and to identify the incidence and causes of jugular bulb oxygen desaturation in patients with acute closed head injury. There were twenty-five patients (30 +/- 16 years) with GCS < or = 8 in this study. Jugular bulb oximetry, mean arterial pressure, intracranial pressure, end-tidal CO2 and pulse oximetry were monitored continuously. Catheter calibration against a laboratory oximeter was performed post insertion and thereafter eight-hourly. Cerebral venous desaturation was defined as a jugular bulb oxygen saturation < 55% of > 10 minutes duration. There was a poor correlation for the first in vivo calibration (r2 = 0.602, P < 0.001, n = 25). Thereafter a close correlation between jugular bulb catheter and oximetry values was demonstrated (r2 = 0.868, P < 0.001, n = 205). Forty-two episodes of jugular bulb oxygen desaturation of 88 minutes mean duration (range 10 to 555) were observed. 83% occurred within 48 hours following injury. Hypocapnia was associated in 45% of episodes; hypoperfusion in 22%; raised ICP in 9% and a combination of the above in 24%. Validation with a laboratory oximeter is essential prior to continuous jugular bulb oximetry. Sustained episodes of cerebral venous desaturation are frequent within the first 48 hours following acute head injury. Factors such as hypocapnia and cerebral hypoperfusion that primarily reduce cerebral blood flow are predominant.

Acute Disease↗

A study of a hospital staff's knowledge of pulse oximetry.

A selection of medical and nursing staff and anaesthetic technicians at work on a particular day at a regional Base Hospital were invited to complete a questionnaire to assess their knowledge of the principles of pulse oximetry. A 98.5% response rate (203 respondents) was achieved from staff in a broad cross section of hospital wards participating in the study. Most of the participants (nursing [N] 87%, medical [M] 91%, anaesthetic technicians [AT] 100%) used pulse oximetry regularly in their daily work. Less than half of the participants (N 36%, M 48% and AT 50%) felt they had adequate training in the use of pulse oximetry. Only 68.5% of participants correctly stated what pulse oximeters measure. Answers to the questions regarding the principles of pulse oximetry, potential errors, normal ranges or the physiology of oxygen haemoglobin dissociation varied but generally reflected limited understanding. As the use of pulse oximeters extends beyond the operating theatre and intensive care environment, appropriate staff education must ensure a basic understanding of the operating principles of the instrument.

Health Knowledge, Attitudes, Practice↗

Capnography in non-tracheally intubated emergency patients as an additional tool in pulse oximetry for prehospital monitoring of respiration.

UNLABELLED: Victims of minor trauma transported by paramedic-based rescue systems are usually monitored with pulse oximetry. Under the difficult surroundings of prehospital trauma care, pulse oximeters show considerable periods of malfunction. We tested the hypothesis that capnography is a good, easy to use tool for monitoring in nonintubated trauma victims. Seventy nonintubated trauma victims were included in this study. Vital variables and number and time of malfunctions were sampled for oximeter and capnometer recordings. Total number of alerts (63 versus 10), number of alerts per patient (3.3 [1.9] versus 0.3 [0.9]) (mean [SD]), total time of malfunction (191.5 [216.7] s versus 11.8 [40.2] s), time of malfunction per alarm (58.3 [71.4] s versus 5.5 [14.6] s), and the percentage of malfunction time during transport (13.2% [15.3%] versus 0.8% [2.8%]) differed significantly (P < 0.01) between oximetry and capnography. Although pulse oximetry is a standard method of monitoring in emergency care, we found capnography to be helpful as a monitoring device. We consequently recommend the use of capnography on transport as an additional monitoring tool to reduce periods lacking supervision of the vital variables. IMPLICATIONS: Capnography is a useful tool to improve respiratory monitoring in nonintubated trauma victims on emergency transport and an easy to use supplement to pulse oximetry.

Adult↗

Screening for sleep apnea using pulse oximetry and a clinical score.

Confirmation of the diagnosis of OSA currently requires overnight polysomnography. This study evaluates the usefulness of pulse oximetry together with a clinical score in identifying OSA. Forty patients were assigned a clinical score based on the presence or absence of loud snoring, observations of interrupted breathing during sleep, hypersomnolence, obesity and essential hypertension. Each underwent a night of domiciliary pulse oximetry followed by nocturnal polysomnography. Significant OSA was confirmed in 26. All 15 patients with positive pulse oximetry tracings had significant OSA (apnea index greater than or equal to 10). Five of eight with negative tracings were also shown to have significant OSA along with six of the seven patients with inadequate or indeterminate tracings. Clinical scores were significantly different for those with and without OSA. This study confirms the usefulness of nocturnal pulse oximetry in establishing the diagnosis of OSA and highlights the value of a clinical score in improving its sensitivity as a screening tool.

Adult↗