Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Metallocenes”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14Linked to original sources

Fast liquid chromatography-electrochemistry-mass spectrometry of ferrocenecarboxylic acid esters.

Rapid liquid chromatographic separations of ferrocenecarboxylic esters of various alcohols and phenols have been achieved on reversed-phase columns of 20 mm length. After separation, the ferrocene derivatives are oxidized electrochemically under formation of the charged ferrocinium species, which are easily detected by mass spectrometry using an atmospheric pressure chemical ionization source operated in the heated nebulizer mode. While a series of nine phenol derivatives was separated within less than 1.5 min, six alcohol derivatives eluted within 1 min. Limits of detection using a single quadrupole mass analyzer ranged from 60 to 190 nmol/l. Additional work was directed on the use of a graphite in-line filter instead of a silica-based reversed-phase column to achieve the separation.

Chromatography, Liquid↗

Chemical modification of proteins under high pressure. Preparation of ferrocene-attached bovine serum albumin and glucose oxidase.

High hydraulic pressure was used for denaturing proteins during chemical modifications. Bovine serum albumin and glucose oxidase were selected as the first targets of this unique technique and the ferrocene group was introduced into them, to obtain a macromolecular electron mediator and a self-electron-mediating oxidase, respectively. The result was compared with those obtained under non-denaturing conditions and under urea-denatured conditions. As for the number of ferrocene group linked to the protein, the pressure denaturation is superior to chemical denaturants, where ferrocenecarboxyaldehyde was used as the modifier. In both proteins the ferrocene group seemed to be introduced mainly inside the molecules with the pressure method, as the native conformation of the protein was restored when the high pressure was removed.

Ferrous Compounds↗

An improved method for the detection of changes in brain extracellular glutamate levels.

We developed a method for in vivo real-time monitoring of the concentration of extracellular glutamate ([Glu]e) in the brain under anoxic conditions. A dialysis electrode (Sycopel Int., UK) was employed as a sensing device to measure the concentration of glutamate by enzyme amperometry, and an electron mediator, ferrocene, was introduced into the electrode together with glutamate oxidase. The ferrocene was covalently conjugated with a high molecular weight molecule, bovine serum albumin, to avoid outward diffusion through the dialysis membrane. With this set-up, the amperometric response was independent of the pO2 around the electrode in vitro up to 400 microM glutamate. Using this method, we investigated the dynamics of [Glu]e in the rat striatum during anoxia. [Glu]e increased rapidly at 102+/-5.4s (n = 6) after the start of nitrogen inhalation. The increase continued for about 30 s, and then [Glu]e decreased. The peak value of delta[Glu]e was 141+/-37 micro M. [Glu]e subsequently underwent another gradual increase, reaching 213+/-69 microM at 15 min after the start of nitrogen inhalation. This distinct biphasic profile was reproducible. We conclude that this method is very useful for monitoring [Glu]e in the brain under low pO2 conditions.

Animals↗

Bioelectronic device consisting of cytochrome c/poly-L-aspartic acid adsorbed hetero-Langmuir-Blodgett films.

A bioelectronic device consisting of protein-adsorbed hetero-Langmuir-Blodgett (LB) films was investigated. Four kinds of functional molecules, cytochrome c, viologen, flavin, and ferrocene, were used as a secondary electron acceptor (A2), a first electron acceptor (A1), a sensitizer (S), and an electron donor (D), respectively. To fabricate the cytochrome c adsorbed hetero-LB film, poly-L-aspartic acid was used as the bridging molecule. The hetero-LB film was fabricated by subsequently depositing ferrocene, flavin, and viologen onto the pretreated ITO glass. Cytochrome c-adsorbed hetero-LB films were prepared by the adsorption of cytochrome c onto the poly-L-aspartic acid treated-LB films by intermolecular electrostatic attraction. Finally, the MIM (metal/insulator/metal) structured molecular device was constructed by depositing aluminum onto the surface of the cytochrome c-adsorbed hetero-LB films. Hetero-LB films were analyzed by Atomic Force Microscopy (AFM), and cytochrome c adsorption onto the films confirmed. The photoswitching function was achieved and the photoinduced unidirectional flow was in accordance with the rectifying characteristics of the molecular device. The direction of energy flow was in accordance with the energy level profile across molecular films. Based on the measurement of the transient photocurrent of the molecular device efficient directional flow of photocurrent through the redox potential difference was observed. The photodiode characteristics of the proposed bio-electronic device were verified and the proposed molecular array mimicking the photosynthetic reaction center could be usefully applied as a model system for the development of the bio-molecular photodiode.

Adsorption↗

Differential response of non-transferrin bound iron uptake in rat liver cells on long-term and short-term treatment with iron.

BACKGROUND: Uptake of non-transferrin-bound iron by the liver is important as a clearance mechanism in iron overload. In contrast to physiological uptake via receptor-mediated endocytosis of transferrin, no regulatory mechanisms for this process are known. This study compares the influence of long-term and short-term depletion and loading of hepatocytes with iron on the uptake of non-transferrin bound iron, its affinity, specificity and the interaction with the transferrin-mediated pathways. METHODS: Rats were fed iron-deficient, normal and 3,5,5-trimethylhexanoyl-ferrocene-containing diets to obtain livers with the corresponding desired status and the hepatocytes from these livers were used for transport studies. Hepatocytes from normal rats were depleted or loaded with iron by short-term treatment with desferrioxamine or ferric ammonium citrate, respectively. Uptake of non-transferrin bound iron was assayed from ferric citrate and from ferric diethylene triammine pentaacetate. RESULTS: Uptake of non-transferrin-bound iron in hepatocytes could be seen as consisting of a high-affinity (Km=600 nM) and a low-affinity component. Whereas in normal and in iron-starved rats the high-affinity component was more prominent, it disappeared altogether in hepatocytes from rats with iron overload resulting from prolonged feeding with TMH-ferrocene-enriched diet. Overloading also led to loss of inhibition by diferric transferrin, which occured in starved as well as normal cells. In contrast, short-term iron-depletion of isolated hepatocytes with desferrioxamine had only a weak stimulatory effect, whereas treatment with ferric ammonium citrate strongly increased the uptake rates. However, the inhibition by diferric transferrin also disappeared. In both cases, uptake of non-transferrin bound iron was inhibited by apotransferrin. CONCLUSIONS: Non-transferrin bound iron uptake in liver cells is apparently regulated by the iron status of the liver. The mode of response to iron loading depends on the method of loading in terms of time course and the form of iron used. It cannot be explained by the behavior of the iron regulatory protein, and it is complex, seeming to involve more than one transport system.

Animal Feed↗

Synthetic ferrocenic mefloquine and quinine analoguesas potential antimalarial agents.

A few years ago we proposed a strategy for the synthesis of new ferrocene-chloroquine analogues replacing the carbon chain of chloroquine by hydrophobic ferrocenyl moieties. Now, this strategy has been applied to the antimalarial amino-alcohols class to afford new potentially active analogues of mefloquine and quinine bearing a substituted ferrocenic group. The pathway used for the synthesis of the mefloquine analogues includes the coupling of an aminomethyl substituted ferrocene carboxaldehyde with a lithio quinoline compound. On the other hand, the synthesis of quinine analogues was ensured by the 'inverse' reaction of a lithio aminomethyl ferrocene with a quinoline carboxaldehyde. The configurations of each diastereoisomer were unambiguously determined by spectroscopic data. The mechanistic interpretations were fully discussed. Ferrocenyl analogues of mefloquine and quinine exhibited a lower antimalarial activity than mefloquine and quinine themselves. Comparing optical isomers, those isomers dissimilar to ferrocenyl derivatives presented better antimalarial activities than those similar to ferrocenyl.

Animals↗

Physico-chemical studies of a DNA triplex containing a new ferrocenemethyl-thymidine residue in the third strand.

The stability of a 16-mer DNA triple helix containing a 3-N(ferrocenemethyl)-thymidine residue in the third strand has been investigated in comparison with the unmodified triplex of the same sequence. A complete physico-chemical characterization of the two triple helices on changing the pH by means of calorimetry, circular dichroism and molecular modeling is therefore reported. The thermodynamic parameters were obtained in the pH range 5.5-7.2 by differential scanning calorimetry (DSC). For both triplexes the T(m) and Delta H degrees (T(m)) values increase on decreasing the pH. In the pH range 7.2-6.0 the triplex containing the ferrocenemethyl nucleoside is less stable than the unmodified one, whereas the modified triplex becomes more stable at pH 5.5. Such difference in stability at each pH value is overwhelmingly enthalpic in origin. CD spectra show conformational changes on decreasing the pH for both the triplexes. By spectroscopic pH titration the apparent pK(a) values of the cytosines in the two triplexes could be estimated, with the cytosines in the TFO containing the ferrocenemethyl residue having lower apparent pK(a) values. These results are consistent with the calorimetric data, showing a decrease of the thermodynamic parameters in the pH range 7.2-6.0 and an increase at pH 5.5 for the ferrocenylated triplex with respect to the unmodified one. The thermodynamic and spectroscopic data are also discussed in relation to molecular models.

Calorimetry, Differential Scanning↗

Electron transfer between ferrocene-modified Au/octadecanethiol/lipid BLM electrode and redox couples in solution.

Bilayers incorporated with ferrocene consisting of self-assembled octadecanethiol and lipid monolayer on gold substrates were fabricated. Its electrochemical behaviors in solutions containing different redox couples were investigated by cyclic voltammetry and ac impedance. The transmembrane electron transfer reaction across octadecanethiol self-assembled film and an adsorbed phospholipid layer mediated by ferrocene have been observed in the solution of Fe(CN)6(3-/4-). The formal potential difference between mediator in bilayer lipid membrane (BLM) and redox couple in solution has a great impact on the transmembrane electron transfer behavior. The ferrocene-modified BLM electrodes might be useful for constructing a bilayer-based electrochemical current rectifying device.

Algorithms↗

Sensitive ferrocene reagents for derivatization of amines for high-performance liquid chromatography with electrochemical detection.

Six reagents possessing ferrocene as an electrophore were prepared and evaluated for pre-column derivatization of amino compounds for their determination by high-performance liquid chromatography with electrochemical detection. The utility of these reagents was investigated employing phenethylamine as a model compound. Among these six, N-succinimidyl 3-ferrocenylpropionate was the best with respect to reactivity, stability and electrochemical properties. The developed method was applied to the determination of putrescine formed from ornithine by ornithine decarboxylase.

Amines↗

Determination and pharmacokinetic study of ferrocene-A in blood serum of rabbits.

Ferrocene-A (ferrocenyl-1-phenyl-1-dioxy-1,4-butin-2) has significant antitumour and antibacterial properties. This study was designed to estimate main pharmacokinetic parameters of ferrocene-A (FC-A). These parameters are very important from the standpoint to elucidate the mechanism of pharmacological action of ferrocene-A. Examined substance was administrated intramuscularly and orally to rabbits. For determination of small quantities of ferrocene-A in a blood plasma liquid-liquid extraction and reversed-phase high performance liquid chromatography (HPLC) method was applied. Kinetic parameters were estimated using the one-compartment linear pharmacokinetic model.

Administration, Oral↗

Ferrocene-avidin conjugates for bioelectrochemical applications.

Coupling of ferrocene moieties to avidin via a flexible spacer molecule yields a conjugate which combines the unique biotin-binding properties of avidin with the reversible redox characteristics of ferrocenes. Synthesis of the conjugate has been optimised and the conjugates were characterised bio- and electrochemically. Covalent immobilisation of the conjugate on gold electrodes in a dense monolayer results in electrodes with a high binding capacity for biotinylated molecules as well as good electron transfer properties. The application potential of such electrodes for bioelectrochemical systems is demonstrated by electrochemical reduction of hydrogen peroxide under mild conditions catalysed by a bound biotin-microperoxidase MP11 conjugate.

Avidin↗

Construction of electrochemical flow immunoassay system using capillary columns and ferrocene conjugated immunoglobulin G for detection of human chorionic gonadotrophin.

In this paper is reported a miniaturized flow immunoassay system. Ferrocenecarboxylic acid (Fc) conjugated with anti-HCG immunoglobulin G (IgG) antibody (Fc-IgG) was prepared, and used as a novel analytical reagent. The system consists of the immunoreaction section, the capillary column packed with cation exchange resin, and the flow cell for electrochemical detection of Fc-IgG. Antibody-antigen complexes were separated from their free conjugate on the basis of differences in isoelectric point (pI) using a cation exchange capillary column. The assay yielded a linear relationship between signal and HCG concentration in the range 0-2000 mIU/ml. This simple technique enables the assay of HCG within 2 min. The cation exchange capillary column was regenerated by occasional elution with malonate buffer (pH 6.0) containing 0.5 M NaCl, to remove free conjugate. Free conjugate recovered in this manner could be reused up to eight times without significant decreases in the sensitivity of the immunoassay. This electrochemical flow immunoassay requires only minute quantities of serum and generates highly reproducible results.

Antigen-Antibody Complex↗

Amperometric glucose sensors based on ferrocene containing polymeric electron transfer systems-a preliminary report.

In this paper we introduce a preliminary work in which a redox mediator containing polyvinylferrocene immobilized on silica gel particles is synthesized. Carbon paste electrodes prepared with this polymeric mediator were studied for their stability in aqueous media for a month. The results indicated that approximately 70% of the initial activity was retained after a month. A steady state amperometric measurement of this carbon paste electrode containing this mediator and glucose oxidase at different potentials showed a linear relationship at elevated glucose concentration.

Adsorption↗

Graphite-Teflon composite bienzyme amperometric biosensors for monitoring of alcohols.

Composite graphite-Teflon electrodes, in which the enzymes alcohol oxidase (AOD) and horseradish peroxidase (HRP), as well as the mediator ferrocene, are incorporated into the electrode matrix, are reported for the reliable monitoring of alcohols in food and beverages. The bienzyme electrodes are constructed by simple physical inclusion of the enzymes and the mediator in the bulk of graphite-70% Teflon rigid cylindrical pellets. The composite biosensors are robust and reusable because of the renewability of the electrode surface by polishing. Reproducible amperometric responses at 0.00 V were obtained with different electrodes constructed from the same pellet and from different pellets. No significant loss of the enzymes activities was found after at least 3 months of storage at 0 degrees C. The detection limits obtained by amperometry in stirred solutions can be advantageously compared with those achieved with commercial sensors for alcohols. The bienzyme electrodes are suitable to be used under flow-injection conditions, as well as for amperometric detection in HPLC. The bioelectrodes were employed for the determination of ethanol in beers, wines and liquors, using both batch- and flow-injection modes, and for the determination of methanol in wines and liquors by HPLC with amperometric detection. Only a dilution of the beverages was needed as sample treatment in all cases.

Alcoholic Beverages↗

Studies on the electrochemical performance of glucose biosensor based on ferrocene encapsulated ORMOSIL and glucose oxidase modified graphite paste electrode.

The electrochemical performance of a new glucose biosensor is reported. The glucose biosensor is developed using glucose oxidase (GOD) and ferrocene encapsulated palladium (Pd)-linked organically modified sol-gel glass (ORMOSIL) material incorporated within graphite paste electrode. The ORMOSIL material incorporated within graphite paste electrode behaves as an excellent electrocatalyst for the oxidation of enzymatically reduced GOD. The electrochemical behavior of new glucose biosensor has been examined by cyclic volammetry and amperometric measurements. The bioelectrocatalysis of ORMOSIL embedded within graphite paste as a function of storage time and varying concentration of ORMOSIL is reported. The initial amperometric response on glucose sensing is recorded to be 145 microA at 15% (w/w) concentration of the ORMOSIL which is decreased to 20 microA at 5% of the same keeping GOD concentration constant. The variation of electrochemical behavior of the ORMOSIL embedded within graphite paste as a function of time has also been studied based on cyclic voltammetry. The voltammograms showing the reversible electrochemistry of ORMOSIL encapsulated ferrocene is changed into a plateau shape as a function of time, however, the electrocatalytic behavior is still retained. The practical usability of new glucose sensor has been compared with earlier developed glucose sensor. The sensitivity, response time and linearity of the new glucose biosensor are found to be excellent over earlier reported glucose biosensor. The amperometric response, calibration curve and practical applications of new glucose sensor are reported.

Biosensing Techniques↗

Redox labelled avidin for enzyme sensor architectures.

Conjugates of avidin with ferrocene and with microperoxidase 8 have been used as electrochemically active molecular building blocks. Assemblies of the conjugates with biotinylated glucose oxidase or lactate oxidase on gold electrodes were tested as enzyme sensors for glucose and lactate. The electrochemical detection is based either on ferrocene-mediated oxidation of the substrate in oxygen-free solution, or on microperoxidase-catalysed reduction of H2O2 which is enzymatically produced from the substrate and molecular oxygen. Glucose and lactate were detectable with both detection principles in concentrations down to 1 or 0.1 mM, respectively. The molecular architecture concept allows quick adaptation of the sensors to other analytes, and it provides a platform for arrays of sensors with different selectivity.

Avidin↗

Mediated electrochemistry of peroxidases--effects of variations in protein and mediator structures.

The kinetics of a range of ferrocene derivatives with horseradish peroxidase (HRP), cytochrome c peroxidase (CCP) and 3 charge reversal mutants of cytochrome c peroxidase were measured using cyclic voltammetry. Substantial differences in rate constant (100 fold) were observed between HRP and CCP for the same mediator with smaller differences (4-5 fold) for different mediators with the same enzyme. The rate constant did not seem to be dependent on redox potential differences. Cluster analysis is proposed as a way of classifying mediator reactivity.

Cytochrome-c Peroxidase↗