Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “MICROWAVES”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14Linked to original sources

Microwave ablation using a spiral antenna design in a porcine thigh muscle preparation: in vivo assessment of temperature profile and lesion geometry.

INTRODUCTION: Theoretical studies have suggested that microwave energy can increase the depth of heating compared with radiofrequency energy. A spiral microwave antenna design may have advantages over previous designs using smaller designs because the resulting power deposition pattern is considerably larger than the catheter diameter. We tested the efficacy of a spiral antenna using microwave energy in a porcine thigh muscle preparation. METHODS AND RESULTS: In five anesthetized pigs, the thigh muscle was exposed and bathed in heparinized bovine blood (36 degrees to 37 degrees C). A helical microwave catheter with a fiberoptic thermometer attached to the distal end was positioned perpendicular to the thigh muscle. The antenna-tissue interface and tissue temperatures at depths of 3.0 and 6.0 mm were measured. A 915-MHz microwave generator delivered energy at one of three power outputs (50, 100, or 150 W) for 60 seconds. Seventy lesions were created: 50 W (n = 23), 100 W (n = 24), and 150 W (n = 23). The mean depths at 50, 100, and 150 W were 4.3 +/- 1.8 mm, 7.2 +/- 1.7 mm, and 9.4 +/- 0.9 mm, respectively. Lesion depth (R = 0.96, P = 0.05), maximum surface dimension (R = 0.99, P = 0.06), and volume (R = 0.99, P = 0.04) were closely correlated to the power applied. CONCLUSION: Power is an important determinant of lesion size using a spiral microwave antenna. A novel, spiral microwave antenna design can create lesions of significant depth that may be applicable for the ablative therapy of ventricular tachycardia.

Animals↗

Microwave disinfection of dentures for the treatment of oral candidiasis.

Thirty-four institutionalized subjects (mean age, 81 years) with a positive test for C. albicans pseudohyphae were randomly assigned to test (microwave) and control (soak) groups. All subjects received the same course of topical antifungal medication (Nystatin 300,000 IU lozenges 3x daily for 14 days). Subjects in the microwave treatment group had their maxillary denture scrubbed and then microwaved for one minute at 850 Watts. This procedure was repeated three times. For subjects receiving the standard denture soak treatment, the nursing staff was instructed to disinfect the maxillary dentures in 0.2% chlorhexidine digluconate solution overnight for 14 days, changing the solution every two days. Infestation of the tissue surface of the maxillary denture with C. albicans progressively took place over the three-month period following treatment such that 8 (53%) of the microwaved dentures and 16 (84%) of the soaked dentures demonstrated pseudohyphae as determined by Gram stain. Infection of the soft tissues with the hyphal form of C. albicans also increased with time. After three months, one (8%) patient in the microwave group and 12 (63%) patients in the denture soak group demonstrated pseudohyphae on the cytological smears. Re-infestation of the denture surface and infection of the adjacent soft tissue were delayed dramatically in patients whose dentures were microwaved compared with those whose dentures were disinfected by being soaked in a chlorhexidine solution. However, microwave treatment is not recommended for all dentures and should be used with caution.

Aged↗

Immunohistochemical analysis of Hodgkin's disease using microwave heating.

AIMS: To assess the effect of microwave heating on immunohistochemical staining of CD15 and CD30 antigens in Hodgkin's disease tissue samples. METHODS: Formalin fixed, paraffin wax embedded sections from 20 cases of Hodgkin's disease (six mixed cellularity, 14 nodular sclerosis) were immunostained for CD15, using two antibodies (DAKO-M1 and Leu-M1) and for CD30 using the antibody Ber-H2. The staining was carried out by conventional techniques which included pretreatment of sections with trypsin and on untreated sections following heating with microwaves. With antibody Leu-M1 an additional method, using a specific antimouse IgM bridge both with and without microwave heating, was also included. The results for each method were compared by counting positively stained Reed-Sternberg cells and estimating the staining intensity. RESULTS: Microwave heating resulted in a substantial increase in the number of cells stained with antibodies to CD15 and also in the staining intensity. The best results were obtained using Leu-M1 with specific rabbit anti-mouse IgM bridge and microwave heating. Dramatic enhancement of the staining of Reed-Sternberg cells for CD30 was achieved following microwave heating, together with disappearance of the non-specific staining of plasma cells. CONCLUSION: Microwave heating is strongly recommended for the immunohistochemical staining of CD15 and CD30 expressed by Reed-Sternberg cells in Hodgkin's disease.

Antigens, CD↗

Liver cancer: increased microwave delivery to ablation zone with cooled-shaft antenna--experimental and clinical studies.

PURPOSE: To prospectively investigate whether the ablation zone induced with microwaves could be increased by delivering greater energy with a cooled-shaft antenna. MATERIALS AND METHODS: All studies were animal care and ethics committee approved. Written informed consent was obtained from all patients. Microwave ablation was performed by using a cooled-shaft antenna in 48 ex vivo and 12 in vivo experiments with porcine livers. The coagulation diameters achieved in different microwave ablation parameter groups (60-90 W for 5-25 minutes) were compared. Ninety patients (78 men, 12 women; mean age, 53 years; age range, 20-82 years) with 133 0.8-8.0-cm (mean, 2.7 cm +/- 1.5 [standard deviation]) primary or metastatic liver cancers were treated with the same microwave ablation technique. Complete ablation (CA) and local tumor progression (LTP) rates were determined. Generalized estimating equations were used to compare differences in tumor size, ablation zone diameter, and CA and LTP rates between different patient subgroups. RESULTS: In the ex vivo livers, in vivo livers, and liver cancers, one application of microwave energy with 80 W for 25 minutes produced mean coagulation diameters of 5.6 x 7.4 cm, 3.5 x 5.9 cm, and 3.6 x 5.0 cm, respectively. Skin burn was not observed. CA rates in small (<or=3.0-cm), intermediate (3.1-5.0-cm), and large (5.1-8.0-cm) liver cancers were 94% (81 of 86), 91% (31 of 34), and 92% (12 of 13), respectively. During a mean follow-up period of 17.4 months, LTP occurred in seven (5%) treated cancers. There was a significant difference in LTP rate between the cirrhosis and no-cirrhosis groups (P = .03). Four patients had major complications. CONCLUSION: Delivery of greater microwave energy with cooled-shaft antennas yielded large ablation zones in ex vivo and in vivo livers and in liver cancers. Effective local tumor control was achieved during one microwave ablation session.

Adult↗

Immunostaining of chain-specific keratins on formalin-fixed, paraffin-embedded tissues: a comparison of various antigen retrieval systems using microwave heating and proteolytic pre-treatments.

The use of chain-specific monoclonal antibodies (MAbs) against keratins in pathology is hampered by their limited staining on formalin-fixed, paraffin-embedded tissue. In the present study, various treatments before immunohistochemistry on paraffin sections were compared, including proteolytic enzymes and microwave antigen retrieval in various solutions. Sections of normal cervical and skin tissue were stained in a three-step immunoperoxidase method, employing a broad panel of MAbs against chain-specific keratins 4, 5, 7, 8, 10, 13, 14, 17, 18, 19 and pankeratin. Using microwave heating, Target Unmasking Fluid (TUF), Antigen Retrieval Solution (ARS), a simple detergent solution (DET), PBS, and distilled water (MiQ) were compared. Microwave heating in PBS or MiQ strongly improved staining results. Moreover, microwave pre-treatment in TUF or DET gave excellent and specific staining with the majority of MAbs tested, comparable with or even better than staining obtained on frozen sections. Using microwave antigen retrieval, tissue morphology remained optimal, and only in a very limited number of MAbs did immunoreactivity on paraffin sections fail to be restored. Proteolytic pre-treatment with trypsin, pepsin, or pronase gave moderate to strong staining with some of the MAbs. Other MAbs, for which microwave pre-treatment was able to restore the loss of immunoreactivity, failed to give appropriate staining with proteolytic pre-treatment. Our results show that microwave heating in either TUF or a simple detergent solution before immunohistochemistry is a reliable method for antigen retrieval of chain-specific keratins in formalin-fixed, paraffin-embedded tissues.

Antibodies, Monoclonal↗

Relation between the size of lesions and arrhythmias produced by microwave catheter ablation with a special electrode device.

The purpose of this study was to examine the effects of microwave catheter ablation of ventricular myocardium. Microwave energy with a frequency of 2450 MHz was delivered via a coaxial catheter with an electrode ball tip. Microwave energy was applied to canine isolated left ventricular endocardium in vitro and to 6 anesthetized dogs in vivo at 50 watts for 15-150 sec. Ventricular arrhythmia was not observed during ablation in any of the dogs when microwave energy was applied for less than 45 sec. When the duration of microwave ablation was greater than 45 sec, ventricular premature contractions were observed in all of the dogs. Nonsustained ventricular tachycardia developed when the duration of microwave delivery was greater than 90 sec. After the cessation of ablation, ventricular arrhythmias did not occur and ventricular programmed stimulation did not induce ventricular tachycardia in any of the dogs. Except for ventricular arrhythmia, no declines in the hemodynamic status were observed in any of the 6 dogs. The size of the ablated lesion was significantly greater as the duration of ablation was increased (p < 0.05). When ablation lasted for more than 120 sec, the coagulation layer was extended to the epicardium in all 6 dogs. The results of this study suggest that microwave ablation is feasible for the treatment of tachyarrhythmias from deep focus of ventricular myocardium with relatively small proarrhythmic effects.

Animals↗

[Eye heating caused by microwave ovens].

To clarify the question as to whether microwave ovens represent a risk for the eyes, a worst-case situation was investigated in which it was assumed that a child observes the internal heating process with its eyes as close to the door of a microwave oven as it is possible to get. As expected, heating of the eyes was observed, which, however, was caused mainly by the conventional heating process rather than by microwave radiation. Significant microwave heating was observed only when increased scattered radiation was simulated by inactivating the safety contacts and opening the door of the microwave oven. When the door is opened to a clearly visible gap width (2.3 cm), the contribution of the microwave component to the overall temperature increase of 5 degrees C after one hour of continuous exposure did not exceed 16%. Even at the maximum possible door gap width which just did not cause the oven to switch off automatically (2.6 cm), 15 minutes of continuous exposure contributed only 50% to the 2 degrees C temperature increase. On the basis of these results, damage to the eye through the use of microwave ovens can be excluded.

Animals↗

Intraoperative triple antenna hepatic microwave ablation.

OBJECTIVE: Microwave ablation is emerging as a new treatment option for patients with unresectable hepatic malignancies. This two-center study shows the results of a phase 1 clinical trial of patients with known hepatic masses who underwent synchronous triple antenna microwave ablation before elective hepatic resection. SUBJECTS AND METHODS: Intraoperative microwave ablation was performed before hepatic resection. Hepatic lesions were targeted using real-time intraoperative sonography with three microwave antennas positioned in a triangular configuration. Microwave ablation was performed at 45 W for 10 minutes. Hepatic resection was then completed in the standard fashion. Gross specimens were sectioned and measured to determine tumor and ablation sizes. Representative areas were stained with H and E stain and vital histochemical nicotinamide adenine dinucleotide (NADH) stain. RESULTS: Ten patients with a mean age of 64 years (range, 48-79 years) were treated. Tumor histology included colorectal carcinoma metastases and hepatocellular carcinoma. The mean maximal tumor diameter was 4.4 cm (range, 2.0-5.7 cm). The mean maximal ablation diameter was 5.5 cm (range, 5.0-6.5 cm), while the average ablation zone volume was 50.8 cm3 (range, 30.3-65.5 cm3). Gross and microscopic examinations of areas after microwave ablation showed clear coagulation necrosis, even surrounding large hepatic vessels (> 3 mm in diameter). A marked thermallike effect was observed with maximal intensity closest to the antenna sites. NADH staining confirmed the uniform absence of viable tumor in the ablation zone. CONCLUSION: This study shows the feasibility of using multiple microwave antennas simultaneously in the treatment of liver tumors intraoperatively. Additional percutaneous studies are currently under way to investigate the safety and efficacy in treating nonsurgical candidates.

Aged↗

CT appearance of hepatic tumors after microwave coagulation therapy.

OBJECTIVE: The purpose of this study was to evaluate the changes in treated lesions and surrounding parenchyma of the liver as well as associated findings on CT in patients who underwent microwave coagulation therapy for hepatic tumors. MATERIALS AND METHODS: We retrospectively reviewed the findings on helical dynamic CT scans obtained before and after percutaneous or intraoperative microwave coagulation therapy for 74 lesions in 63 patients with hepatocellular carcinoma or metastatic hepatic tumors. Indications for microwave coagulation therapy included primary hepatic tumors in 54 patients and hepatic metastasis in nine patients. Sixty percent nonionic contrast material, infused at 3 ml/sec, was followed by sequential arterial phase, portal venous phase, and equilibrium phase helical CT of the entire liver in all patients. RESULTS: All lesions were hypodense and extended to the liver capsule. The lesions treated with percutaneous microwave coagulation therapy were teardrop-shaped, whereas those treated with intraoperative microwave coagulation therapy were round. Peripheral enhancement was seen on contrast-enhanced CT in 93% of the treated lesions immediately after microwave coagulation therapy; however, such enhancement disappeared on follow-up CT. Hemorrhage within the lesions and pleural effusion were found in nine patients. Complications detected on CT included intratumoral abscess (n = 4), subcapsular hematoma (n = 2), tumor dissemination (n = 3), ascites (n = 5), and portal vein thrombosis (n = 1). CONCLUSION: CT of the liver in patients undergoing microwave coagulation therapy showed findings that were dependent on the technique of therapy. Thus, CT scans must be carefully analyzed to avoid confusing results of therapy with findings that indicate complications requiring further treatment.

Aged↗

Factors affecting lead leaching from microwavable plastic ware made with lead-containing pigments.

Although food contact polymers do not normally contain lead, it is suspected that lead may be leached from some microwavable plastic ware items made in Thailand with lead-containing pigments. The purpose of this study was to examine relationships with regard to lead leached from microwavable plastic ware. Four factors were studied: pH, heat level, extraction time, and number of repeated extractions. A total of 243 samples of microwavable plastic ware items locally manufactured in Thailand were used. This study used three pH values (3.5, 4.5, and 6.5) and three heat levels (levels 3, 6, and 9 [170, 500, and 850 W, respectively]). Acetic acid was used both as the extracting agent and for adjusting the pH. Samples were collected at each level at 1, 3, and 5 min, and the amount of leached lead was measured with an atomic adsorption spectrometer. The results of this study show that pH, heat, and extraction time affected the amount of lead leaching from microwavable plastic ware. The amount of lead leaching increased with decreasing pH but increased with increasing heat level and extraction time. On the basis of these three factors, the results of this study indicate that the pH of the extractant (r = -0.592, P < 0.01), the heat level of extraction (r = 0.293, P < 0.01), the extraction time (r = 0.226, P < 0.01), and the number of extractions (r = -0.153, P < 0.01) are related to lead leaching from microwavable plastic ware. The relationship between the pH of the extractant, the heat level of extraction, and the extraction time significantly moderated lead leaching from microwavable plastic ware (R2 = 0.511, P < 0.001). For all factors, the amount of lead leaching was lower than the permissible level of 1 mg/liter specified by the Minister of Public Health. In conclusion, a combination of high acid, prolonged heating, and extraction time accelerated the amount of lead leaching from microwavable plastic ware, but the incidence of lead leaching was negligible.

Acetic Acid↗

The use of microwave ovens by elderly persons with disabilities.

OBJECTIVE: This study examined the effectiveness of microwave ovens in assisting elderly persons with disabilities with cooking food. METHOD: The participants were five elderly persons who had gross motor, fine motor, or vision impairments but no cognitive impairments. Before the study, none of the participants owned or operated a microwave oven. In this single-subject design of four phases (ABAB), training in microwave oven use was provided between the first A (baseline) and first B (intervention) phases. Participants had access so the microwave oven in their homes only during the B phases. Each phase lasted for 3 weeks, for a total of 12 weeks. The frequency of using cooking appliances, the number of food items prepared, and the time spent preparing meals were recorded through daily self-reports. RESULTS: All participants showed an increase in the frequency of using cooking appliances for at least one of the two B phases, although they showed different patterns. The number of food items prepared increased in the B phases, except for two participants who were ill. With the introduction of the microwave oven, time spent preparing meals decreased for all five participants, and their participation in meal preparation increased. Although not measured as a study variable, results suggest that the quality of diet also improved with microwave oven use. CONCLUSION: Occupational therapy practitioners who serve elderly clients might consider recommending microwave ovens for those who do not have cognitive impairments but who are having difficulty with cooking because of vision impairments or physical disabilities.

Activities of Daily Living↗

Microwave coagulation therapy for multiple hepatic metastases from colorectal carcinoma.

BACKGROUND: Compared with other treatments, microwave coagulation is a relatively less invasive treatment for various kinds of solid tumors. Although its effectiveness in primary hepatocellular carcinoma has been shown, its effectiveness in the treatment of hepatic metastases from colorectal carcinoma has been unclear. The aim of this study was to evaluate its effectiveness in the treatment of multiple hepatic metastases from colorectal carcinoma by comparing this technique with that of hepatic resection. METHODS: Thirty patients with multiple metastatic colorectal tumors in the liver who were potentially amenable to hepatic resection were randomly assigned to treatment with microwave coagulation (14 patients) or hepatectomy (16 patients). Tumors in the microwave group were coagulated after laparotomy at an output of 60-100 W for 2-20 minutes under the guide of ultrasonography, whereas tumors in the hepatectomy group were treated with lobectomy, segmentectomy, subsegmentectomy, and/or wedge resection. RESULTS: One-, 2-, and 3-year survival rates and mean survival times were 71%, 57%, 14%, and 27 months, respectively, in the microwave group, whereas they were 69%, 56%, 23%, and 25 months, respectively, in the hepatectomy group. The difference between these two groups was statistically not significant (P = 0.83). On the other hand, the amount of intraoperative blood loss in the microwave group (360 +/- 230 mL) was smaller than that in the hepatectomy group (910 +/- 490 mL, P < 0.05). Blood transfusion was necessary for 6 patients in the hepatectomy group, but it was not necessary in the microwave group. CONCLUSIONS: Microwave coagulation therapy is suggested to be equally effective as hepatic resection in the treatment of multiple (two to nine) hepatic metastases from colorectal carcinoma, whereas its surgical invasiveness is less than that of hepatic resection.

Adult↗

Some mechanical properties of a highly cross-linked, microwave-polymerized, injection-molded denture base polymer.

PURPOSE: The impact strength and the flexural properties of denture base materials are of importance in predicting their clinical performance upon sudden loading. This study compares the impact and transverse strengths and the flexural modulus of three denture base polymers. MATERIALS AND METHODS: The investigation included a relatively new microwave-polymerized polyurethane-based denture material processed by an injection-molding technique, a conventional microwave-polymerized denture material, and a heat-polymerized compression-molded poly(methyl methacrylate) (PMMA) denture material. Impact strength was determined using a Charpy-type impact tester. The transverse strength and the flexural modulus were assessed with a three-point bending test. The results were subjected to statistical analysis using a one-way analysis of variance and the Scheffé test for comparison. RESULTS: The impact strength of the microwave-polymerized injection-molded polymer was 6.3 kl/m2, while its flexural strength was 66.2 MPa. These values were lower than those shown by the two compression-molded PMMA-based polymers. The differences were statistically significant. The flexural modulus of the new denture material was 2,832 MPa, which was higher than the conventional heat-polymerized polymer but was comparable to the other microwave-polymerized PMMA-based polymer. The difference in the flexural modulus was statistically significant. CONCLUSION: In terms of the impact and flexural strengths, the new microwave-polymerized, injection-molded, polyurethane-based polymer offered no advantage over the existing heat- and microwave-polymerized PMMA-based denture base polymers. However, it has a rigidity comparable to that of the microwave-polymerized PMMA polymer.

Acrylic Resins↗

[Comparison of microwave coagulation using a new type electrode with radiofrequency ablation in the liver of living animals].

In the present study, we compared microwave coagulation using a new type of electrode, a teflon-coated electrode that was developed in order to increase the area of coagulation, with radiofrequency ablation using a Radionics Cool-tip electrode inserted into the pig liver. Two Landrace male pig were put under general anesthesia. A microwave electrode (insulated area: 6 mm, teflon-coated electrode 16 G) and a radiofreqency (RF) electrode (Cool-tip RF single electrode 17 G) were passed through the surface of the livers of the pig. A thermometer was placed 1 cm from the tip of the electrode in order to measure the changes in the temperature of the area surrounding the electrode. In this study, the microwave setting was 80 W, and the RF pulse was set automatically. The coagulated and ablated areas of the liver were measured after 2.5, 5, and 10 minutes of energy delivery (n = 4). The diameter of the coagulated area of the liver following 2.5, 5 and 10 minutes of microwave exposure was 23.5 +/- 4.8 mm, 29.5 +/- 5.2 mm and 32.5 +/- 6.4 mm, respectively. On the other hand, the diameter of the ablated area of the liver following 2.5, 5 and 10 minutes of RF exposure was 18.5 +/- 4.1 mm, 24 +/- 7.8 mm and 28 +/- 4.9 mm, respectively. The mean temperature of the liver 1 cm from the microwave and RF electrodes (measured time: 2 minutes) was 69.6 degrees C and 56.3 degrees C. respectively (n = 12). Thus, the temperature of the area surrounding the microwave electrode was significantly higher than the temperature of the area surrounding the RF electrode (p = 0.0065). The teflon-coated microwave electrode achieved superior results to the Radionics Cool-tip electrode with respect to the diameter of the coagulated area and the temperature of the area in which the electrode was inserted, at the specified times.

Animals↗

Variability in catheter microwave sterilization techniques in a single clinic population.

PURPOSE: We designed a survey to assess the microwave sterilization technique practiced by patients at our clinic who perform clean intermittent catheterization. MATERIALS AND METHODS: A 23-question survey addressing urinary catheter use and home sterilization techniques was mailed to 129 patients. A followup survey was mailed to 47 respondents who reported using a microwave oven to sterilize the catheters to assess the microwave technique further. RESULTS: Of the 129 initial surveys 84 (64%) were returned, while 40 (85%) of the 47 followup questionnaires on microwave sterilization were returned. All patients surveyed have used clean intermittent catheterization for at least 1 year and 75% have used it more than 5 years. Of the respondents 80% perform clean intermittent catheterization 4 to 5 times daily, although sterilization frequency varies from daily to less than once weekly. Of the respondents 71% reported no difficulty with microwave sterilization, although 31 (63%) reported a history of catheter melting during microwaving. Of the respondents 35% reported using a rotation table, all used a heat sink containing 1/2 to 4 cups of water, 39% used 500 to 1,000 W., 37% used greater than 1,000 W., 73% set the microwave for 6 minutes, others set it for 3 to 30 minutes and 98% used a power setting described as high, full, 10 or 100%. CONCLUSIONS: Significant variation exists in the cleaning and sterilizing techniques used by our patients, although they were given uniform written and verbal instructions. It is unclear from the data in the literature how this variation affects sterilization.

Ambulatory Care↗

[An experiment on disinfection using high power microwave].

This experimental disinfection was intended to examine the effect of high power microwave on bacteria, and the putative nonthermal effect. The bacteria of the experimental groups were irradiated by high power microwave in different intensities and time and were compared with the controls--bacteria heated only. The principles of disinfection by means of high power microwave were studied. The results showed that the temperature did not change after the dry bacteria were irradiated by high power microwave in different intensities and time, but the number of bacteria alive decreased significantly(P < 0.05). The high power microwave's effect of disinfection was greater in the wet bacteria group than in the dry bacteria group and the bacteria heated group. These data indicate that the disinfection effect of high power microwave is higher than that of heating. High power microwave can kill dry bacteria, and it has the nonthermal effect in addition to its thermal effect.

Disinfection↗

[Effect of microwave coagulation and surgery to treat the cancer of the floor of mouth].

OBJECTIVE: The aim of this article was to clarify the value of microwave coagulation to treat the cancer of the floor of mouth by comparing the effect of microwave and surgery. METHODS: Retrospectively 87 cases of cancer of the floor of mouth who were treated by microwave coagulation and traditional surgery are analysed and the survival curve, the recurrent rate of the primary and secondary site, the oral functions, the appearance and the complications are compared. RESULTS: 1. Either in the early patients (T1 + T2) or in the advanced cases (T3 + T4), the differences of survival curve between the two groups were insignificant (P = 0.8247, P = 0.803 respectively); 2. The recurrent rate of the primary and secondary site were insignificant either (P = 0.988, P = 0.759 respectively); 3. There were more patients with a satisfied mouth function in the microwave coagulation group than that of in the surgery group, on the contrary, the cases with a worst function were few in the former(P = 0.000, P = 0.001 respectively); 4. The appearance was more satisfactory in the microwave group(chi 2 = 23.077, P = 0.000). CONCLUSIONS: To treat the cancer of the floor of mouth, microwave coagulation, as the traditional surgery, had good effects such as the same survival rate, the complication rate and local or region control rate, but the mouth function and the appearance was better than the surgery group. The microwave coagulation can be safely carried out in the practice.

Adult↗

[Effect of hepatic artery embolization on the microwave coagulated area].

OBJECTIVE: To study the effect of hepatic artery embolization on the microwave coagulated area, an in vivo animal experiment. METHODS: Twenty-four suitable hepatic lobes of ten dogs were divided into two groups: microwave coagulation alone 12 lobes (control group) and hepatic artery occlusion with iodized oil and gelatin sponge particles followed by microwave coagulation 12 (experiment group). Microwave coagulation was delivered with an output of 50 W for 300 or 400 seconds with thermal needles introduced parallel to and 5 approximately 20 mm from the puncture needle. After sacrifice of the dogs, their hepatic lobes were sectioned along the puncture line. Then, the appearance and size of the coagulated area were recorded. The tissue specimens were fixed in formalin for light microscopic evaluation. RESULTS: A decline in temperature gradient was detected from the center to the periphery of the affected tissue after the application of microwave coagulation, which was sharper in the control group than in the experimental group. Single polar microwave coagulation at 50 W for 300 seconds produced a necrotic volume of 25 approximately 33 mm in longitudinal diameter and 13 approximately 22 mm in transverse diameter in control group, 33 approximately 44 mm and 24 approximately 32 mm in the experimental group. The coagulation area was slightly bigger when the duration of coagulation was 400 seconds than 300 seconds, without significant difference. CONCLUSION: Hepatic artery occlusion, inhibiting the heat loss caused by hepatic arterial blood flow, is able to significantly enlarge the necrotic volume of microwave coagulation.

Animals↗