Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Fast Neutrons”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14Linked to original sources

Membrane solubilization in erythrocytes as a measure of radiation exposure to fast neutrons.

Membrane solubilization and osmotic fragility of rat erythrocytes irradiated in vivo with fast neutron fluences ranging from 10(6) to 5 x 10(7) n cm(-2) using a 252Cf source were measured instantaneously using a light scattering technique. The solubilization of erythrocyte membrane by a non-ionic detergent, octylglucoside (OG), was found to exhibit a two stage transition from vesicular form to mixed micellar form in the range of detergent concentrations 1.5-7.8 mM. The coexistence phase, vesicular/mixed micellar, was shifted towards higher detergent concentrations with increase in the neutron fluence, indicating increasing membrane resistance to the detergent and hence change in the natural membrane permeation properties. The technique shows an adequate sensitivity in detecting membrane damage in erythrocytes and has potential as a biophysical marker of radiation exposure. The osmotic fragility of irradiated erythrocytes shows a decreasing trend with increasing irradiation fluence measured directly and two weeks post-irradiation. Blood films photographed two weeks post-irradiation show developed elliptocytosis and crenated cell anaemia.

Animals↗

A method to detect low-level 63Ni activity for estimating fast neutron fluence from the Hiroshima atomic bomb.

The Hiroshima and Nagasaki atomic bombs resulted in the worst reported exposure of radiation to the human body. The data of survivors have provided the basis for the risk estimation for ionizing radiation, and thus are widely used as the basis of radiation safety. In this report we have studied a new method to detect the low-level 63Ni activity in copper samples in order to estimate the fast neutron fluence from the Hiroshima atomic bomb. Only 0.8 x 10(-3) Bq g(-1) of 63Ni is expected to be produced by the atomic bomb in a copper sample with the 63Cu(n, p)63Ni reaction at a distance of 500 m from the hypocenter. Our method has the required level of sensitivity for determination of the fast neutron fluence out to distances of at least 500 m, and perhaps as far as 1,000 m. We have already investigated and collected some bomb-irradiated copper samples for further study.

Beta Particles↗

RBE variation between fast neutron beams as a function of energy. Intercomparison involving 7 neutrontherapy facilities.

In fast neutron therapy, the relative biological effectiveness (RBE) of a given beam varies to a large extent with the neutron energy spectrum. This spectrum depends primarily on the energy of the incident particles and on the nuclear reaction used for neutron production. However, it also depends on other factors which are specific to the local facility, eg, target, collimation system, etc. Therefore direct radiobiological intercomparisons are justified. The present paper reports the results of an intercomparison performed at seven neutrontherapy centres: Orléans, France (p(34)+Be), Riyadh, Saudi Arabia (p(26)+Be), Ghent, Belgium (d(14.5)+Be), Faure, South Africa (p(66)+Be), Detroit, USA (d(48)+Be), Nice, France (p(65)+Be) and Louvain-la-Neuve, Belgium (p(65)+Be). The selected radiobiological system was intestinal crypt regeneration in mice after single fraction irradiation. The observed RBE values (ref cobalt-60 gamma-rays) were 1.79 +/- 0.10, 1.84 +/- 0.07, 2.24 +/- 0.11, 1.55 +/- 0.04, 1.51 +/- 0.03, 1.50 +/- 0.04 and 1.52 +/- 0.04, respectively. When machine availability permitted, additional factors were studied: two vs one fraction (Ghent, Louvain-la-Neuve), dose rate (Detroit), influence of depth in phantom (Faure, Detroit, Nice, Louvain-la-Neuve). In addition, at Orléans and Ghent, RBEs were also determined for LD50 at 6 days after selective abdominal irradiation and were found to be equal to the RBEs for crypt regeneration. The radiobiological intercomparisons were always combined with direct dosimetric intercomparisons and, when possible in some centres, with microdosimetric investigations.

Abdomen↗

A modified lead attenuation method to determine the fast neutron sensitivity kU of a photon dosemeter.

Various lead attenuation techniques to determine the fast neutron sensitivity kU of a photon dosemeter are reviewed and a modified method is proposed to determine the kU value of a commercially available Geiger--Müller detector. The dependence on the 'effective' photon energy of the gamma-component of the mixed n--gamma field is illustrated and the most probable photon energy is deduced from measurements outside the radiation field. Using the relevant photon mass attenuation coefficient, measurements carried out with a well-collimated neutron beam at the MRC Cyclotron, Hammersmith Hospital, London, show that the Dg component contributes 2.41 +/- 0.13% to the total radiation field. Using a detector with a PTFE sleeve in the place of a Perspex sleeve, highly consistent results are obtained and the enhancement of the kU value by the Perspex is demonstrated. The neutron sensitivities of two MX 163 GM detectors with Perspex and PTFE sleeves were respectively determined as 0.73 +/- 0.07% and 0.98 +/- 0.14%.

Elementary Particles↗

Distortion of fast-neutron dose distribution by bone.

The influence of bone on dose distributions due to fast neutrons generated at the Naval Research Laboratory (NRL) Cyclotron was investigated. A paired dosimeter consisting of a parallel-plate, tissue-equivalent ionization chamber and thermoluminscent material was used to partition the absorbed dose into neutron and gamma-ray components. Several thicknesses of bone were simulated using bone-equivalent liquid and plastic. Based on these measurements, the authors conclude that, as a result of the increased absorption of neutrons by bone, lower dose levels are found behind bone would be predicted from dose distributions in muscle-equivalent liquid.

Bone and Bones↗

Re-irradiation of locally recurrent tumors with fast neutrons.

Forty-six patients with locally recurrent disease were re-irradiated with fast neutrons at Fermilab. All had received prior radical radiation therapy either with or without surgery. Six were palliative. Forty patients treated with curative intent were analyzed for local response, survival, and complications. The overall response rate was 78% (31/40); 50% (20/40) had a complete local response. Ten of 16 patients (63%) with non-epidermoid carcinomas in the head and neck regions had complete response, whereas only nine of twenty patients (45%) with epidermoid carcinomas were complete responders. In a subset of 12 patients with salivary gland type tumors, 10 had a complete response (83%). Two of these 10 patients are alive beyond 5 years. Observed median survival for the forty patients was 9.3 months, and for complete responders 14.4 months. Observed median survival for partial responders was only 7.5 months. Four of six patients treated for palliation had significant subjective improvement. Significant morbidity, Grade III or greater (EORTC/RTOG scale), was seen in only 10 patients (25%), and this was found to depend directly on the total dose delivered. We conclude that neutron beam therapy can be used as a therapeutic modality for patients with recurrent tumors with an acceptable degree of morbidity.

Adenocarcinoma↗

[A case of successful treatment of resistant tumors with fast neutrons].

The authors report two cases of resistant to standard treatment tumors cured by fast neutrons. The recurrence-free period after the treatment with 6.0 MeV neutrons lasted 5 and 2 years for follicular thyroid cancer and breast cancer metastases, respectively. To avoid acute radiation reaction of the laryngeal mucosa copper laser radiation was used.

Adenocarcinoma, Follicular↗

[Radiobiology in clinical trials for fast neutron therapy, with special reference to the treatment of malignant melanoma].

Clinical trials with fast neutrons have been advocated by the features of the beam, characterized by low oxygen enhancement ratio as well as low repair capability of the irradiated cells. The results show that for selected tumors, locally advanced, local control rates were excellent, whereas the effects of the beam have not been fully satisfied on the treatment of advanced carcinoma of the tongue and squamous cell carcinoma of the uterine cervix. Evaluating the results treating the patients suffering from malignant melanoma, the meaning of radiobiology was discussed in use of high LET radiations for clinical radiotherapy.

Aged↗

Functional changes in the pig kidney following irradiation with fractionated doses of fast neutrons (42 MeVd-->Be).

The right kidney of female Large White pigs, approximately 14 weeks old, was irradiated with fractionated doses of fast neutrons (42 MeVd-->Be). The total doses used were 6.6-9.2 Gy. Changes in kidney function, assessed as the functional index (FI, where FI = irradiated kidney function/unirradiated kidney function) or as individual kidney glomerular filtration rate (GFR) and effective renal plasma flow (ERPF), were serially determined up to 104 weeks after irradiation using 99Tcm-DTPA and 131I-hippuran renography. The animals were then euthanized, the kidneys removed and weighed. A dose-dependent reduction in FI was seen within 13 weeks of irradiation. Measuring individual kidney function revealed a hyperaemic response in both irradiated and unirradiated kidney 4 weeks after irradiation. This was followed by a dose-dependent reduction in irradiated kidney GFR and particularly ERPF. The ED50 value for the impairment in ERPF, assessed as the percentage of irradiated kidneys exhibiting a > or = 50% reduction in ERPF, was significantly lower than that for GFR, i.e. 7.20 +/- 0.10 Gy compared with 8.44 +/- 0.07 Gy (p < 0.001). A dose-related reduction in irradiated kidney weight was also observed. These fast neutron-induced changes in renal function and weight are qualitatively similar to those observed following photon irradiation of the pig kidney.

Animals↗

Development of a fast neutron spectrometer composed of silicon-SSD and position-sensitive proportional counters.

A new fast neutron spectrometer has been developed. The spectrometer is composed of a silicon surface barrier detector and three position-sensitive proportional counters with methane gas working as counting gas and a radiator. A collimated incident neutron interacts with a hydrogen atom in the methane gas to generate a recoil proton. The position information on the path of the recoil proton obtained from the three position-sensitive proportional counters gives the recoil angle. In the meanwhile, the energy of the recoil protons is measured with the three proportional counters and the silicon surface barrier detector. The characteristics of the spectrometer were evaluated with a monoenergetic neutron beam. The best energy resolution was 1.8% for 5.0 MeV neutrons.

Computer Simulation↗

PIN silicon diode fast neutron detector.

Two batches of diodes, with different structural ratios (the ratio of area and thickness), were made using different manufacturing processes. The energy response of the first batch to 15 kinds of monoenergetic neutrons ranging from 180 keV to 17.56 MeV was tested, and the neutron source response of both batches to 239Pu-Be neutron source was measured. The energy deposition in the diodes irradiated by 1 keV to 20 MeV monoenergetic neutrons was calculated with simulation procedure. The response curve of the experimental results showed an approximately similar trend to that of theoretical computation. Based on the results of the neutron source response experiments, it was concluded that the response of fast neutron varied linearly with the structural ratio of the detectors.

Fast Neutrons↗

Unusual alkaline elution pattern induced in mammalian cell DNA by fast neutrons p(34) + Be.

Syrian hamster fibroblasts (cell line BHK 21/13) were exposed to p(34) + Be fast neutron irradiation and their DNA analysed by the alkaline elution technique. The elution profiles showed an unusual tailing off, characteristic of neutron-irradiated samples, suggesting the presence of a modification in DNA induced by the neutrons. This was not seen with 60Co gamma-irradiation. In neutron-irradiated samples the alteration of DNA appeared to persist even after 2 h of post-treatment incubation (37 degrees C) indicating the absence of repair. The modification of DNA induced by neutrons provides a possible explanation for the reduction of the shoulders in survival curves obtained with neutrons, and the high RBE of neutrons.

Animals↗

Measurements of neutron spectra at depths in tissue equivalent material for fast neutron beams generated by deuterons on beryllium.

The threshold foil technique has been used to investigate the behaviour in tissue of the spectra of neutron beams produced by the bombardment of thick Be targets with 13-0 and 20-5 MeV deuterons. The results indicate a gradual "softening" with depth in tissue of the spectrum generated by 20-5 MeV deutrons which contrasts with a gradual hardening as reported by other authors. This is discussed in terms of the significance of field size and the methods used for data collection and analysis.

Beryllium↗