Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Electroplating”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14Linked to original sources

Chronological changes of MRI findings on striatal damage after acute cyanide intoxication: pathogenesis of the damage and its selectivity, and prevention for neurological sequelae: a case report.

A 31-year-old male technician in an electroplating factory, who had been suffering from the temporal lobe epilepsy for 24 years and from hypertension for 2 years, took an unknown amount of potassium cyanide apparently over the lethal dose, in an attempt to commit suicide. He was treated successfully and survived without any neurological sequelae. The electroencephalograms and the nature of the seizures were not different before and after the poisoning. The T2-weighted magnetic resonance images at 9 and 51 days after the poisoning showed bilateral elevation of signals in the caudate nuclei and the putamina. At the 143th and 286th days. T2-weighted high-resonance areas were restricted to the lateral portion of the putamina. The T1-weighted images at the 51st day showed abnormal signal elevations in both putamina, while those of 9th, 143th and 286th days were mainly normal. Selective vulnerability of the putamen and the caudate nucleus may be due to their specific structural properties of high oxygen and glucose utilization, and enzyme distribution. Both chronological changes of striatal damage and the absence of neurological sequelae in this patient suggest the possibility that anti-epileptics and a calcium antagonist played a neuroprotective role in the acute cyanide intoxication.

Adult↗

Occupational exposure to Cr(VI): comparison between chromium levels in lymphocytes, erythrocytes, and urine.

The relationships between chromium (Cr) levels in lymphocytes, erythrocytes, urine, and ambient air were compared among 14 chrome-platers from a metallurgic plant in Bulgaria and two groups of local controls, one from the same heavily polluted industrial town as the chrome-platers (n = 11) and one from a seaside resort town 100 km away (n = 6). Among the chrome-platers, the Cr concentration in peripheral lymphocytes was positively correlated with total Cr and Cr(VI) levels in ambient air and with Cr excretion in urine. As compared to the controls, the chrome-platers had mean Cr levels in lymphocytes twice as high, in erythrocytes ninefold higher, and in urine fourfold to eightfold higher. Although Cr levels in urine and lymphocytes were similar between the two control groups, levels in erythrocytes were 3 times higher among subjects from the industrial area than among those from the seaside town. The study suggests that lymphocyte Cr could be a good indicator of the Cr body burden caused by high exposures to Cr(VI), such as in electroplating operations. In these conditions, erythrocyte Cr may be less useful, possibly owing to increased toxicity due to the high affinity of erythrocytes for Cr. However, when exposure is lower, such as in most environmental situations, erythrocyte Cr should provide a better and more sensitive index than lymphocyte Cr. By contrast, urinary Cr, which provides information on total Cr exposure, including Cr(III) from dietary and environmental sources, does not seem to be of value for studying occupational exposure to Cr(VI).

Adult↗

The construction of Schistosoma japonicum vaccine BCG-Sj26GST and its identification.

The expression of foreign gene, Schistosoma Japonicum 26 ku antigen (Sj26GST), in Bacillus Calmette-Guerin (BCG), Mycobacterium (M. smegmatis) and Escherichia coli (E. coli) were studied. The cDNA fragment encoding Sj26GST was amplified by PCR using plasmid pGEX, which could express Sj26GST in E. coli as template. The Sj26GST cDNA was cloned into the down-stream of human M. tuberculosis heat shock protein (hsp) 70 promoter with correct reading frame, and then the DNA fragment containing hsp70 promoter and Sj26GST gene were subcloned together into E. coli-Mycobacteria shuttle plasmid pBCG-2000 to construct the expression shuttle plasmid pBCG-Sj26. The recombinant BCG and M. smegmatis mc(2)155, which were electroplated with pBCG-Sj26, could express Sj26GST and the recombinant Schistosoma Japonicum vaccine BCG-Sj26GST was made. The recombinant Sj26GST (rSj26GST) were soluble and could be observed on SDS-PAGE at molecular weight of 26 ku. The content of rSj26GST accounted for 15% and 10% of total bacterial protein in BCG and M. smegmatis respectively. The results of Western blot showed the combination of rSj26GST with antibody of GST.

Animals↗

Biosorption of nickel in complex aqueous waste streams by cyanobacteria.

A study was undertaken to determined if a suitable biosorbent could be found for removal of nickel at low concentrations (< 20 parts per million [ppm]) from a chemically complex wastewater effluent generated by electroplating operations. Algae and cyanobacteria were chosen as candidate biosorbent materials because they are easy to grow and they have the ability to withstand processing into biosorbent materials. Several species were screened for nickel-biosorption capacity initially, and three species of cyanobacteria were selected for further study based on their performance in the scoping tests. When compared to live controls, autoclaving improved the binding capacities of all three species, but usually biosorption data from experiments with live cells were more consistent. None of the three species was able to bind nickel efficiently in actual effluent samples. Further experimentation indicated that sodium ions, which were present in high concentrations in the effluent, were interfering with the ability of the cells to bind nickel. Adsorption isotherm plots for biosorption of nickel by two species of Anabaena in NiCl2-deionized water solutions were prepared.

Adsorption↗

Arsenate detoxification in a Pseudomonad hypertolerant to arsenic.

Pseudomonas sp. strain As-1, obtained from an electroplating industrial effluent, was capable of growing aerobically in growth medium supplemented with up to 65 mM arsenate (As (V)), significantly higher concentrations than those tolerated by other reference arsenic resistant bacteria. The majority of the arsenic was detected in culture supernatants as arsenite (As (III)) and X-ray absorbance spectroscopy suggested that 30% of this cell-bound arsenic was As (V), 65% As (III) and 5% of arsenic was associated with sulphur. PCR analysis using primers designed against arsenic resistance genes of other Gram-negative bacteria confirmed the presence of an arsenic resistance operon comprising of three genes, arsR, arsB and arsC in order of predicted transcription, and consistent with a role in intracellular reduction of As (V) and efflux of As (III). In addition to this classical arsenic resistance mechanism, other biochemical responses to arsenic were implicated. Novel arsenic-binding proteins were purified from cellular fractions, while proteomic analysis of arsenic-induced cultures identified the upregulation of additional proteins not normally associated with the metabolism of arsenic. Cross-talk with a network of proteins involved in phosphate metabolism was suggested by these studies, consistent with the similarity between the phosphate and arsenate anions.

Arsenates↗

Determination of (236)U and transuranium elements in depleted uranium ammunition by alpha-spectrometry and ICP-MS.

It is well known that ammunition containing depleted uranium (DU) was used by NATO during the Balkan conflict. To evaluate the origin of DU (the enrichment of natural uranium or the reprocessing of spent nuclear fuel) it is necessary to directly detect the presence of activation products ((236)U, (239)Pu, (240)Pu, (241)Am, and (237)Np) in the ammunition. In this work the analysis of actinides by alpha-spectrometry was compared with that by inductively coupled plasma mass spectrometry (ICP-MS) after selective separation of ultratraces of transuranium elements from the uranium matrix. (242)Pu and (243)Am were added to calculate the chemical yield. Plutonium was separated from uranium by extraction chromatography, using tri- n-octylamine (TNOA), with a decontamination factor higher than 10(6); after elution plutonium was determined by ICP-MS ((239)Pu and (240)Pu) and alpha-spectrometry ((239+240)Pu) after electroplating. The concentration of Pu in two DU penetrator samples was 7 x 10(-12) g g(-1) and 2 x 10(-11) g g(-1). The (240)Pu/(239)Pu isotope ratio in one penetrator sample (0.12+/-0.04) was significantly lower than the (240)Pu/(239)Pu ratios found in two soil samples from Kosovo (0.35+/-0.10 and 0.27+/-0.07). (241)Am was separated by extraction chromatography, using di(2-ethylhexyl)phosphoric acid (HDEHP), with a decontamination factor as high as 10(7). The concentration of (241)Am in the penetrator samples was 2.7 x 10(-14) g g(-1) and <9.4 x 10(-15) g g(-1). In addition (237)Np was detected at ultratrace levels. In general, ICP-MS and alpha-spectrometry results were in good agreement. The presence of anthropogenic radionuclides ((236)U, (239)Pu,(240)Pu, (241)Am, and (237)Np) in the penetrators indicates that at least part of the uranium originated from the reprocessing of nuclear fuel. Because the concentrations of radionuclides are very low, their radiotoxicological effect is negligible.

Journal Article↗

Speciation analysis of chromium by separation on a 5-palmitoyl oxine-functionalized XAD-2 resin and spectrophotometric determination with diphenylcarbazide.

The method developed in this work for the separation and preconcentration of Cr(III) is based on its retention by an Amberlite XAD-2 copolymer resin functionalized with 5-palmitoyl-8-hydroxyquinoline (oxine), abbreviated XAD-POx, with the ligand covalently bound to the copolymer. Cr(III) sorption was quantitative within the pH range 4.5-7.0 and Cr(VI) was not retained. The Cr(III) held by the resin column was eluted with a hot solution of H(2)O(2) in pH>or=9.0 aqueous NH(3)-NH(4)Cl buffer, and Cr oxidized to CrO(4)(2-) was rejected by the chelating cation-exchanger column. Any Cr(VI) originally present with Cr(III) could be reduced with an acidic solution of H(2)O(2), and retained by the column yielding total Cr results, Cr(VI) being determined from the difference. The resin showed a maximal preconcentration factor of 60 for Cr(III), the LOD and LOQ being 9.3 and 30.1 nmol L(-1), respectively. The developed preconcentration-speciation analysis was finished with a diphenylcarbazide (DPC) spectrophotometric procedure suitable for conventional laboratories. The resin showed excellent salt tolerance, enabling Cr analysis in seawater, and was stable over extended use. All the interferents of this procedure that normally occur in an electroplating effluent, a blended coal CRM, and a standard steel sample could be removed by the recommended procedure, by use of partial and total selectivity at the adsorption and desorption stages, respectively, enabling preconcentration and colorimetric determination of chromium in various complex matrices.

Journal Article↗

Coated wire chromium(III) ion-selective electrode based on azamacrocycles.

Tetraazacyclotetradecane, tetratosyltetraaza 12C4, and tritosyltriaza 9C3 have been explored as electroactive materials for preparing coated wire ion-selective electrodes (CWISEs) for Cr(III) ions. The best performance was observed for the membrane comprising electroactive material (tetratosyltetraaza 12C4), plasticizer (dibutyl phthalate), and poly(vinyl chloride) in the optimum ratio 5:60:35 (w/w). Linear Nernstian response for this electrode was obtained over the total Cr(III) concentration range of 1 x 10(-1) to 1 x 10(-7) M in 0.05 M NH4NO3 medium, with a slope of 20 +/- 1 mV per decade change. The working pH range of the electrode was 1.8-5.5. Selectivity coefficients of some mono, divalent, and trivalent metal ions were determined. Analyses of electroplating bath solutions, chromating, and effluent samples have been carried out using this CWISE and the results are found to be comparable with those obtained by using conventional methods or by AAS.

Journal Article↗

Multiplexed SNP genotyping using nanobarcode particle technology.

Single-nucleotide polymorphisms (SNP) are the most common form of sequence variation in the human genome. Large-scale studies demand high-throughput SNP genotyping platforms. Here we demonstrate the potential of encoded nanowires for use in a particles-based universal array for high-throughput SNP genotyping. The particles are encoded sub-micron metallic nanorods manufactured by electroplating inert metals such as gold and silver into templates and releasing the resulting striped nanoparticles. The power of this technology is that the particles are intrinsically encoded by virtue of the different reflectivity of adjacent metal stripes, enabling the generation of many thousands of unique encoded substrates. Using SNP found within the cytochrome P450 gene family, and a universal short oligonucleotide ligation strategy, we have demonstrated the simultaneous genotyping of 15 SNP; a format requiring discrimination of 30 encoded nanowires (one per allele). To demonstrate applicability to real-world applications, 160 genotypes were determined from multiplex PCR products from 20 genomic DNA samples.

DNA↗

Ion-exchange behavior of stannic selenoiodate and stannic selenosilicate: analytical application of stannic selenoiodate.

Two new inorganic ion exchangers, stannic selenoiodate and stannic selenosilicate have been synthesized. The ion-exchange capacity of stannic selenoiodate and stannic selenosilicate for K+ was found to be 1.84 and 1.23 meq g(-1), respectively. pH titration studies reveal monofunctional and bifunctional behavior for stannic selenosilicate and stannic selenoiodate, respectively. Distribution coefficients of metal ions in dimethylformamide-HCl and formamide-HCl systems have been determined. Some important and analytically difficult quantitative binary and ternary separations, and selective separations of Ag+, Sn4+, Zr4+, Co2+, and Ni2+ have been achieved on stannic selenoiodate columns. The practical utility of the material has been demonstrated by analyzing the metal ion content of electroplating waste.

Journal Article↗

Analytical performance characteristics of thin and thick film amperometric microcells.

The analytical performance of amperometric microcells with different electrode geometries is compared for enzyme activity measurements. The microcells were fabricated with thin film photolithography or thick film screen-printing in four different designs. The cells made with the thin film process used flexible substrate with microelectrode array or a circular, disk-shaped working electrode. The screen-printed working electrodes had semicircle or disk shape on ceramic chips. Putrescine oxidase (PUO) activity measurement was used as a model. The determination of PUO activity is important in the clinical diagnosis of premature rupture of the amniotic membrane. An electropolymerized m-phenylenediamine size-exclusion layer was used to eliminate common interferences. The size exclusion layer revealed also to be advantageous in protecting the electrodes from fouling by putrescine (enzyme substrate). The electrode fouling of bare electrodes was insignificant for screen-printed electrodes, but very severe for electroplated platinum working electrodes. The microelectrode array electrodes demonstrated smaller RSD and higher normalized sensitivities for hydrogen peroxide and PUO activity. All the other electrodes were demonstrating comparable analytical performances.

Electrochemistry↗

Speciation studies by capillary electrophoresis- Simultaneous determination of chromium(III) and chromium(VI).

A method for the simultaneous determination of chromium(III) and chromium(VI) by capillary electrophoresis (CE) has been developed. The chromium(III) has been chelated with 1,2-cyclohexanediaminetetraacetic acid (CDTA) in order to impart a negative charge and similar mobility to both the chromium(III) and the chromium(VI) species. The effects of the amount of the reagent, pH and heating time required to complete the complexation have been studied. Factors affecting the CE behaviour such as the polarity of electrodes and the pH of electrophoretic buffer have been investigated. The separated species have been monitored by direct UV measurements at 214 nm. The detection limits achieved are 10 microg/l for Cr(VI) and 5 microg/l for Cr(III) and linear detector response is observed up to 100 mg/l. The procedure has been applied to the determination of both chromium species in industrial electroplating samples and its accuracy was checked by comparing the results (as total chromium) with those of atomic absorption spectrometry. No interference occurred from transition metal impurities under optimized separation conditions. The method is also shown to be feasible for determining Cr(III) as well as other metal ions capable to form complexes with CDTA (like iron(III), copper(II), zinc(II) and manganese(II)) in pharmaceutical preparations of essential trace elements.

Journal Article↗

Angiotensin-II stimulates nitric oxide release in isolated perfused renal resistance arteries.

Nitric oxide (NO) has been implicated as a modulator of the vascular effects of angiotensin II (ANG II) in the kidney. We used a NO-sensitive microelectrode to study the effect of ANG II on NO release, and to determine the effect of selective inhibition of the ANG II subtype I receptor (AT1) with losartan (LOS) and candesartan (CAN). NO release from isolated and perfused renal resistance arteries was measured with a porphyrin-electroplated, carbon fiber. The vessels were microdissected from isolated perfused rat kidneys and perfused at constant flow and pressure in vitro. The NO-electrode was placed inside the glass collection cannula to measure vessel effluent NO concentration. ANG II stimulated NO release in a dose-dependent fashion: 0.1 nM, 10 nM and 1000 nM ANG II increased NO-oxidation current by 85+/-18 pA (n = 11), 148+/-22 pA (n = 11), and 193+/-29 pA (n = 11), respectively. These currents correspond to changes in effluent NO concentration of 3.4+/-0.5 nM, 6.1+/-1.1 nM, and 8.2+/-1.3 nM, respectively. Neither LOS (1 muM) nor CAN (1 nM) significantly affected basal NO production, but both AT1-receptor blockers markedly blunted NO release in response to ANG II (10 nM): 77+/-6% inhibition with LOS (n = 8) and 63+/-9% with CAN (n = 8). These results are the first to demonstrate that ANG II stimulates NO release in isolated renal resistance arteries, and that ANG II-induced NO release is blunted by simultaneous AT1-receptor blockade. Our findings suggest that endothelium-dependent modulation of ANG II-induced vasoconstriction in renal resistance arteries is mediated, at least in part, by AT1-receptor-dependent NO release.

Angiotensin II↗

Bacterial removal of chromium (VI) and (III) in a continuous system.

The capacity of Acidithiobacillus ferrooxidans and Acidithiobacillus thiooxidans to reduce different concentrations of hexavalent chromium in shake flask cultures has been investigated. A. ferrooxidans reduces 100% of chromium (VI) at concentrations of 1, 2.5 and 5 ppm, but in the presence of 10 ppm only 42.9% of chromium (VI) was reduced after 11 days of incubation. A. thiooxidans showed a lower capacity to reduce this ion and total reduction of chromium (VI) was only obtained for concentrations of 1 and 2.5 ppm, whereas 64.7% and 30.5% was reached for 5 and 10 ppm, respectively, after 11 days. A continuous flow mode system was subsequently investigated, in which A. thiooxidans was immobilized on elemental sulphur and the acidic medium obtained was employed to solubilize chromium (III) and to reduce chromium (VI) present in a real electroplating waste [30% of chromium (III) and 0.1% of chromium (VI)]. The system enabled the reduction of 92.7% of hexavalent chromium and represents a promising way to treat this type of waste in the industry.

Acidithiobacillus↗

Characterization and identification of the sources of chromium, zinc, lead, cadmium, nickel, manganese and iron in PM10 particulates at the two sites of Kolkata, India.

Monitoring of ambient PM10 (particulate matter which passes through a size selective impactor inlet with a 50% efficiency cut-off at 10 microm aerodynamic diameter) has been done at residential (Kasba) and industrial (Cossipore) sites of an urban region of Kolkata during November 2003 to November 2004. These sites were selected depending on the dominant anthropogenic activities. Metal constituents of atmospheric PM10 deposited on glass fibre filter paper were estimated using Inductively Coupled Plasma Atomic Emission Spectrometer (ICP-AES). Chromium (Cr), zinc (Zn), lead (Pb), cadmium (Cd), nickel (Ni), manganese (Mn) and iron (Fe) are the seven toxic trace metals quantified from the measured PM10 concentrations. The 24 h average concentrations of Cr, Zn, Pb, Cd, Ni, Mn and Fe from ninety PM10 particulate samples of Kolkata were found to be 6.9, 506.1, 79.1, 3.3, 7.4, 2.4 and 103.6 ng/m3, respectively. The 24 h average PM10 concentration exceeded national ambient air quality standard (NAAQS) as specified by central pollution control board, India at both residential (Kasba) and industrial (Cossipore) areas with mean concentration of 140.1 and 196.6 microg/m3, respectively. A simultaneous meteorology study was performed to assess the influence of air masses by wind speed, wind direction, rainfall, relative humidity and temperature. The measured toxic trace metals generally showed inverse relationship with wind speed, relative humidity and temperature. Factor analysis, a receptor modeling technique has been used for identification of the possible sources contributing to the PM10. Varimax rotated factor analysis identified four possible sources of measured trace metals comprising solid waste dumping, vehicular traffic with the influence of road dust, road dust and soil dust at residential site (Kasba), while vehicular traffic with the influence of soil dust, road dust, galvanizing and electroplating industry, and tanning industry at industrial site (Cossipore).

Air Movements↗

A copper-based intrauterine device with gold or platinum core: in vitro and in vivo studies.

The use of copper intrauterine contraceptive devices is currently limited to 2-3 years, mainly due to wire fragmentation, which was observed as early as after 8 months of use. In the resulting search for a long-lasting device, two new systems of duplex wire, with gold and platinum cores electrolytically coated with copper, were devised and studied. Initially, duplex wires and controls were exposed to physiological solution. Copper dissolution rate, and corrosion morphology were studied by weight-loss measurements and optical metallography. Similar systems were then surgically implanted in rat uteri for varying periods up to 26 weeks. Electron microanalysis of corrosion products in addition to weight-loss measurements and metallography was performed. The results showed that a uniform and ductile copper coating is obtainable by electroplating on gold and platinum wires. The rate of copper dissolution is similar to that of solid copper wire. No dissolution of gold and platinum in the controls or coated wires was detected by weight loss, metallography or atomic absorption measurements. Microanalysis of the deposits and corrosion products on the wires in the uterine environment showed the presence of compounds containing sulphur, chlorine, calcium and copper. The results of this study suggest that supplementing IUDs with copper-coated gold or platinum wires may result in significant prolongation of the life-span of the device by preventing uncontrolled loss of copper caused by wire fragmentation.

Animals↗

A simple 18O water target for 18F production.

A simple low-volume (3 mL) target has been constructed for the production of 18F via the proton irradiation of 18O enriched water. The target is constructed of copper with the water cavity electroplated with nickel. This target routinely produces more than a curie of 18F (as [18F]fluoride) suitable for radiopharmaceutical syntheses.

Fluorine↗