Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Digitation junction”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14Linked to original sources

Anatomic considerations of anterior transarticular screw fixation for atlantoaxial instability.

STUDY DESIGN: Anatomic parameters of C1 and C2 were measured in 30 dried human cervical spines. Anterior transarticular C1-C2 screws were placed in 15 cadaveric spines. OBJECTIVE: To provide anatomic data for anterior transarticular atlantoaxial screw or C1-C2 screw and plate fixation. SUMMARY OF BACKGROUND DATA: A posterior approach to fixation in the atlantoaxial joint has been well described. Damage to the vertebral artery is documented as a rare complication of posterior atlantoaxial transarticular screw fixation. An anterior surgical approach to exposing the upper cervical spine for internal fixation and bone graft recently has been developed. No anatomic information regarding the anterior transarticular atlantoaxial screw or screw and plate fixation between C1 and C2 is available in the literature. METHODS: Direct measurements using digital calipers and a goniometer were taken from 30 pairs of dried human C1 and C2 vertebrae. The anterior transarticular C1-C2 screw insertion point is at the junction of the lateral edge of the C2 vertebral body to 4 mm above the inferior edge of the C2 anterior arch. The parameters related to anterior transarticular atlantoaxial screw fixation or screw and plate fixation between the C1 lateral mass and the C2 vertebral body were measured. Fifteen embalmed cadavers were used for anterior C1-C2 transarticular screw placement. Longer screws (30-40 mm) were used to detect whether the screw tips violated the upper cervical canal or vertebral arteries. RESULTS: In the anterior transarticular atlantoaxial screw placement, lateral angulation of the screw placement relative to sagittal plane ranged from 4.8 +/- 1.8 degrees to 25.3 +/- 2.6 degrees. The posterior angulation of the screw placement relative to the coronal plane ranged from 12.8 +/- 3.1 degrees to 22.6 +/- 3.2 degrees. The length of the medial screw path ranged from 14.7 +/- 1.5 mm to 25.4 +/- 2.8 mm. In the anterior screw and plate fixation, the anteroposterior diameter of the inferior facet articular surface ranged from 16.2 +/- 1.6 mm to 17.1 +/- 1.8 mm. The anteroposterior diameter of the C2 vertebral body ranged from 9.3 +/- 1 mm to 16.2 +/- 1.8 mm. The anterior prevascular retropharyngeal approach appropriately exposed the atlantoaxial joint for anterior transarticular C1-C2 screw placement. No screws violated the vertebral artery and cervical canal. CONCLUSIONS: An anterior transarticular atlantoaxial screw 15-25 mm long can be inserted with a lateral angulation of 5-25 degrees relative to the sagittal plane and a posterior angulation of 10-25 degrees relative to the coronal plane. Additionally, in C1-C2 anterior plate fixation screws 15 mm long could be anchored in the inferior facet of the C1, and screws 9-15 mm long could be anchored in the C2 vertebral body.

Aged↗

An off-line digital system for reproducible interpretation of the exercise ECG.

Exercise electrocardiograms of 20 patients were analyzed using a customized software exercise electrocardiographic program and compared to measurements made by two cardiologists performing independent interpretations. The computerized program requires identification of the PQ junction, J point, and tracing of the ST-segment in three consecutive beats. The proportion of variance for J point, and ST 80 measurements was 0.93 and 0.90, respectively, when the same electrocardiogram was processed twice and analyzed by two separate cardiologists. The same 20 exercise electrocardiograms were analyzed by two other experienced cardiologists without computerized measurements. The proportion of variance was less at 0.73 and 0.76 for the J point and ST 80 measurements, respectively. The average amount of time required for the cardiologist to over read the computerized measurements was 2.7 +/- 1.5 minutes per ECG as compared to 20.7 +/- 11 minutes for the cardiologists who did not have computer-assisted measurements (p less than 0.0001). Thus, off-line computerized exercise electrocardiographic interpretation is highly reproducible, accurate, time-sparing for cardiologist over read function, and suitable for use in large-scale clinical trials.

Coronary Disease↗

The digital pads of rhacophorid tree-frogs.

The digital pads of rhacophorid tree-frogs were studied by light and electron microscopy using a tannic acid-containing fixative. The digital pads are concave mucous epithelial structures surrounded by a soft raised epithelial border. The cells in the first epithelial layer are separated by deep intercellular fissures and the epithelial cell surface is densely covered with thousands of setaceous keratinized microvilli. These are estimated to be 0.1-0.5 microm in width and have flattened tips. A longitudinal section view of the pad's first epithelial cell layer shows a rugose pattern. Deep intercellular fissures in between the cells are formed by the enzymatic activity of invading mononuclear leukocytes in the interepithelial cell junctions. The 'rugose' surface epithelial cell layer is peeled off from the underlying second epithelial layer by the epithelial metabolism that occurs when the leukocytes invade the second interepithelial cell spaces. Thus, the second epithelial cell layer becomes the new 'rugose' epithelial cell layer. The ultrastructures of the frog digital pads are compared with those of other biological suction cups, such as those of octopuses and geckos. Further discussed are their interatomic or intermolecular mechanofunctional aspects, such as hanging upside down and moving easily over smooth surfaces with the aid of interatomic or intermolecular forces, the so-called 'van der Waals forces', without any energy expenditure.

Animals↗

Instrumentation of the cervicothoracic junction after destabilization.

STUDY DESIGN: The biomechanics of three different instrumentation constructs applied at the destabilized cervicothoracic junction were evaluated. OBJECTIVES: To find an efficient way in restoring stability of the cervicothoracic junction in cases with and without laminectomy. SUMMARY OF BACKGROUND DATA: Different instrumentation techniques have been evaluated biomechanically and used clinically for managing instabilities between the fourth and sixth cervical vertebrae. These constructs have not been evaluated at the cervicothoracic junction. METHODS: Six human spines were tested nondestructively in axial torsion, flexion, and extension with the C6-T2 motion segments left unconstrained. The three-dimensional displacements and rotations between C7 and T1 vertebrae were measured using a sonic digitizer. After intact testing, a distractive-flexion Stage 3 cervical spinal injury was simulated surgically between C7 and T1. The specimens underwent sequential instrumentation and mechanical testing with three constructs: posterior Synthes lateral mass plate, posterior pediatric Cotrel-Dubousset rod system with lamina hooks and a crosslink, and anterior Synthes cervical locking plate. RESULTS: Posterior stabilization techniques had statistically more stiffness than anterior plates. The Cotrel-Dubousset system offered the largest stiffness ratio (instrumented/intact) in flexion, extension, and rotation. There was no statistical difference between posterior plates and Cotrel-Dubousset instrumentation. The stiffness of the anterior plate did not differ significantly from the intact spine. CONCLUSION: Our data show that instability of the cervicothoracic junction can be efficiently restored by either anterior plates, posterior plates, or posterior hook-rod constructs (Cotrel-Dubousset). Posterior constructs showed increased stiffness over anterior plates.

Aged↗

Dosimetric consequences of manual pullback procedure for coronary artery radiotherapy with 90Sr/90Y beta-source.

PURPOSE: This work presents a quantitative dosimetric analysis of the Novoste (90)Sr/(90)Y beta-source cardiovascular brachytherapy treatments using a manual pullback technique for patients with in-stent restenosis. METHODS AND MATERIALS: Based on our previous measurements, a model was developed to estimate the dose in the middle of the junction region for tandem irradiation expressed as fraction of prescription dose (FPD) and dosimetric overlap length (DOL) receiving more/less than a threshold dose. The overlap/gap size was measured using the digital cine images recorded during treatment and then FPD and DOL were quantified. RESULTS: Statistical analysis of 55 patients showed that the overlap size and the FPD at 2 mm radial distance were in range of 0 to 23 mm and 13-200% of prescription dose (Rx), respectively. Four gaps out of 76 pullback cases were found, but their size was at most 5 mm. CONCLUSION: Use of a 5 mm overlap avoided underdosed regions in the vast majority of the cases. These results are the first step towards an analysis of the clinical outcome of these patients.

Brachytherapy↗

Topological analysis of trabecular bone MR images.

Recently, imaging techniques have become available which permit nondestructive analysis of the three-dimensional (3-D) architecture of trabecular bone (TB), which forms a network of interconnected plates and rods. Most osteoporotic fractures occur at locations rich in TB, which has spurred the search for architectural parameters as determinants of bone strength. In this paper, we present a new approach to quantitative characterization of the 3-D microarchitecture of TB, based on digital topology. The method classifies each voxel of the 3-D structure based on the connectivity information of neighboring voxels. Following conversion of the 3-D digital image to a skeletonized surface representation containing only one-dimensional (1-D) and two-dimensional (2-D) structures, each voxel is classified as a curve, surface, or junction. The method has been validated by means of synthesized images and has subsequently been applied to TB images from the human wrist. The topological parameters were found to predict Young's modulus (YM) for uniaxial loading, specifically, the surface-to-curve ratio was found to be the single strongest predictor of YM (r2 = 0.69). Finally, the method has been applied to TB images from a group of patients showing very large variations in topological parameters that parallel much smaller changes in bone volume fraction (BVF).

Aged↗

[Sarcomatoid carcinoma of the prostate].

The authors report a case of sarcomatoid carcinoma of the prostate in a 49-year-old patient. The clinical symptoms were dominated by dysuria and frequency. Digital rectal examination showed a very large, hard and irregular prostate. Serum PSA was normal. Transrectal ultrasonography and abdominopelvic computed tomography showed a heterogeneous mass occupying the vesico-prostatic junction. The patient underwent cystoprostatectomy. Histological examination of the cystoprostatectomy specimen revealed a tumour composed of spindle cells expressing epithelial markers on immunohistochemical analysis and concluded on a diagnosis of sarcomatoid carcinoma of the prostate. The patient died seven months after cystoprostatectomy.

Carcinosarcoma↗

2D Thick-section MR digital subtraction angiography for the assessment of dural arteriovenous fistulas.

BACKGROUND AND PURPOSE: Although dynamic contrast-enhanced MR angiography studies for arteriovenous malformations (AVFs) and brain tumors have shown promising results, no formal attempt has yet been made to similarly evaluate dural AVFs. To assess the practical applicability of 2D thick-section contrast enhanced MR digital subtraction angiography (MRDSA) for the diagnosis and management of dural AVFs, MRDSA and intra-arterial digital subtraction angiography (IADSA) were comparatively evaluated. METHODS: We performed 80 consecutive MRDSA studies for 25 dural AVFs, including 11 cavenous sinuses, 9 sigmoid sinuses, 2 tentorial sinuses, one anterior condylar vein, one craniocervical junction, and one spine. MR images were continuously obtained following the initiation of a bolus injection of gadrinium chelates and subtraction images were constructed. We thereafter evaluated the imaging quality and hemodynamic information from all 46 MRDSA images performed in parallel with IADSA in either perioperative or follow-up studies. RESULTS: Most MRDSA images detected early venous filling, sinus occlusion, leptomeningeal venous drainage, and varices. It was difficult, however, to identify the feeding arteries because of both the partial volume effect and a low spatial resolution. Most important, MRDSA accurately detected aggressive lesions with leptomeningeal venous drainage and varices. CONCLUSION: Our MRDSA technique was found to have limited value for depicting all the anatomic details of dural AVFs, though it was able to identify important hemodynamic abnormalities related to the risk of hemorrhaging. MRDSA is therefore useful as a less invasive, dynamic angiographic tool, not only for perioperative studies but also for follow-up studies.

Adult↗

Radiographic assessment of impacted mandibular third molar sockets filled with composite xenogenic bone graft.

OBJECTIVES: The main purpose of this study was to evaluate the radiographic aspect of the healing of extraction sockets filled with a xenogenic graft material (Gent-tech). METHODS: Thirty-nine patients ranging in age from 15 years to 25 years with bilateral impacted mandibular molars were chosen based on bilateral mandibular similarities. After tooth extraction, the socket was filled with the graft. The opposite site was left to heal naturally and served as a control. The experimental and control sites were chosen randomly. Bone density and crest healing were evaluated on digital radiographs taken immediately, 2 months and 6 months after surgery. The respective pixels values obtained with the Digora software were compared statistically. RESULTS: The results showed a significant decrease in the distance from the cemento-enamel junction to the alveolar bone crest, but no difference was found between the control and experimental groups. Bone density increased significantly, and there was difference between experimental and control groups. CONCLUSION: The analysed parameters observed by the authors were similar to those of the control group, suggesting xenogenic graft being an acceptable material and a graft option.

Absorbable Implants↗

Computerized videodefecography versus defecography: do we need radiographs?

CONTEXT AND OBJECTIVE: Defecography has been recognized as a valuable method for evaluating patients with evacuation disorders. It consists of the use of static radiography and fluoroscopy to record different situations within anorectal dynamics. Conventionally, rectal parameters are measured using radiograms. It is rare for fluoroscopy alone to be used. Computer software has been developed with the specific aim of calculating these measurements from digitized videotaped images obtained during fluoroscopy, without the need for radiographic film, thereby developing a computerized videodefecography method. The objective was thus to compare measurements obtained via computerized videodefecography with conventional measurements and to discuss the advantages of the new method. DESIGN AND SETTING: Prospective study at the radiology service of Hospital das Clínicas, Universidade de São Paulo. METHOD: Ten consecutive normal subjects underwent videodefecography. The anorectal angle, anorectal junction, puborectalis muscle length, anal canal length and degree of anal relaxation were obtained via the conventional method (using radiography film) and via computerized videodefecography using the ANGDIST software. Measurement and analysis of these parameters was performed by two independent physicians. RESULTS: Statistical analysis confirmed that the measurements obtained through direct radiography film assessment and using digital image analysis (computerized videodefecography) were equivalent. CONCLUSIONS: Computerized videodefecography is equivalent to the traditional defecography examination. It has the advantage of offering reduced radiation exposure through saving on the use of radiography.

Adult↗

Aneurysmal bone cyst of the atlas: successful treatment through selective arterial embolization: case report.

OBJECTIVE AND IMPORTANCE: Aneurysmal bone cysts (ABCs) are benign and expansile osteolytic lesions that can occur in any location in the spine, including the craniovertebral junction. Aggressive resection followed by bone grafting has been the mainstay of treatment, with selective arterial embolization as a presurgical adjunct. Complete excision of these lesions at the craniovertebral junction is associated with high surgical morbidity. We report a case of successful treatment of an ABC of the atlas in a child with selective arterial embolization alone. CLINICAL PRESENTATION: A 10-year-old girl presented with persistent neck pain after a snowboarding accident. Computed tomography and magnetic resonance imaging of the cervical spine revealed an expansile cystic mass involving the right lateral mass of C1. Digital subtraction angiography revealed a tumor blush, which, along with the cystic appearance of the lesion, was consistent with an ABC. INTERVENTION: The arterial feeders to the lesion were selectively embolized with polyvinyl alcohol particles. Three sessions of embolization were required to eradicate the blood supply to the lesion completely. CONCLUSION: Complete surgical resection of ABCs at the craniovertebral junction can be associated with high morbidity secondary to the highly vascular and destructive nature of these lesions. The case discussed here demonstrates the viability of selective arterial embolization as a primary and stand-alone modality of treatment.

Bone Cysts, Aneurysmal↗

The effects of octanol on penicillin induced epileptiform activity in rats: an in vivo study.

The common features of all types of epilepsy are the synchronized and uncontrolled discharges of nerve cell assemblies. The reason for the pathologically synchronized discharges of the neuron is not exactly known yet. Recent reports claim that gap junctions have a critical role in neuronal synchronization. The present study was planned to investigate the effects of octanol, a gap junction blocker, on penicillin-induced experimental epilepsy. Permanent screw electrodes allowing EEG monitoring from conscious animals and permanent cannula providing the administration of the substances to the brain ventricle were placed into the cranium of rats under general anesthesia. After the postoperative recovery period, epileptiform activity was generated by injecting 300 IU crystallized penicillin through the ventricular cannula. When epileptiform activity, monitored from a digital recording system, reached at its maximum intensity, octanol was applied in the same way as penicillin administered. Application of octanol caused an inhibition in the epileptiform activity. Vehicle solution alone did not affect the epileptiform activity. Results of this study suggest that the blockade of electrical synapses may contribute to the prevention and amelioration of epileptic activity. Production of gap junction blockers selective for connexin types is needed. Further studies on the differential roles of gap junctions on certain epileptiform activities are required.

Animals↗

An evaluation of eight peripheral nerve stimulators for monitoring neuromuscular blockade.

The features of eight commercially available peripheral nerve stimulators were compared with those evolved as ideal for monitoring neuromuscular blockade. The pulse waveforms were satisfactory except for that delivered by the CIG series 80 nerve/muscle stimulator. The error in timing of the stimulation patterns was up to 60% in the Professional Instruments NS-2C compared with 8% or less in the other devices. All of the stimulators had maximum current outputs suitable for monitoring with surface stimulating electrodes. The current delivered by the CIG series 80 nerve/muscle stimulator and the Stimlocator SL1.4 sagged by 21% and 25% respectively during a tetanus. The Digistim III, Bard Biomedical 750 digital and the Professional Instruments NS-2C had accurate digital readouts of delivered current.

Electric Stimulation↗

On-line analysis of neuromuscular bioelectric potentials.

A computer system is presented which provides for on-line data capture and analysis of evoked end-plate potentials and action potentials, and on-line data capture with off-line analysis of spontaneously occurring miniature end-plate potentials at the end-plate region of the neuromuscular junction. Sampling of evoked waveforms begins after an adjustable delay following the stimulus. Spontaneously occurring waveforms are captured by 'freezing' the contents of a circular buffer. The software provides MENU selectable support functions including storage and retrieval of data and calculated parameters, analog and digital display of waveforms, data calibration and gain modification, data editing, file management, and hardcopy output. Calculated parameters of the waveform are optionally placed in a data base file by the analysis programs. The data base may be used for editing, arithmetic operations, and subsetting of variables as well as statistical analysis and plotting of any selected variables.

Action Potentials↗

Safety of radiofrequency treatment over human skin previously injected with medium-term injectable soft-tissue augmentation materials: a controlled pilot trial.

BACKGROUND AND OBJECTIVES: Several soft-tissue augmentation materials are now available for reduction of nasolabial fold creases and perioral rhytides. Nasolabial folds and perioral rhytides can also be improved by skin tightening delivered by non-ablative radiofrequency (RF) treatment. The purpose of this study was to assess the safety of RF treatment over skin areas recently injected with medium-term injectable soft-tissue augmentation materials. STUDY DESIGN/MATERIALS AND METHODS: Five subjects were assigned to the experimental arm (augmentation materials plus RF) and one to the control arm (augmentation materials alone). Each subject received injections of 0.3 mL of hyaluronic acid derivative (Restylane) and calcium hydroxylapatite (Radiesse) 3 cm apart on the upper inner arm. Two weeks later, two non-overlapping passes of RF (Thermage ThermaCool TC) were delivered at 63.5 setting with medium-fast 1.5 cm2 tip over injected sites in all of the experimental subjects. Punch skin biopsies were obtained 3 days later from each of the two injection sites on each subject. RESULTS: Light microscopy and digital photomicrographs obtained at low, medium, and high power showed no difference between filler materials in experimental and control subjects. In both cases filler was evident at the deep dermal-subcutaneous junction. Nodule formation, foreign body extravasation, or hemorrhage/clot was not observed grossly or histologically. Subjects and physicians did not report any difference in signs and symptoms between the experimental and control arms. Slightly increased transitory pain was noted when RF was delivered over filler versus over normal skin. CONCLUSION: Applying RF treatment over the same area 2 weeks after deep dermal injection with hyaluronic acid derivatives or calcium hydroxylapatite does not appear to cause gross morphological changes in the filler material or surrounding skin. Further studies with different parameters are necessary to confirm these findings.

Adult↗

Modern human molar enamel thickness and enamel-dentine junction shape.

This study examines cross-sections of molar crowns in a diverse modern human sample to quantify variation in enamel thickness and enamel-dentine junction (EDJ) shape. Histological sections were generated from molars sectioned buccolingually across mesial cusps. Enamel cap area, dentine area, EDJ length, and bi-cervical diameter were measured on micrographs using a digitizing tablet. Nine landmarks along the EDJ were defined, and X and Y coordinates were digitized in order to quantify EDJ shape. Upper molars show greater values for the components of enamel thickness, leading to significantly greater average enamel thickness than in lower molars. Average enamel thickness increased significantly from M1 to M3 in both molar rows, due to significantly increasing enamel cap area in upper molars, and decreasing dentine area in lower molars. Differences in EDJ shape were found among maxillary molars in combined and individual populations. Sex differences were also found; males showed significantly greater dentine area, EDJ length, and bi-cervical diameters in certain tooth types, which resulted in females having significantly thicker average enamel. Differences in enamel thickness and EDJ shape within molars were also found among populations, although few consistent trends were evident. This study demonstrates that enamel thickness and EDJ shape vary among molars, between sexes, and among populations; these factors must be considered in the categorization and comparison of ape and human molars, particularly when isolated teeth or fossil taxa are included. Human relative enamel thickness encompasses most values reported for fossil apes and humans, suggesting limited taxonomic value when considered alone.

Animals↗

Segmental cervical spine motion during orotracheal intubation of the intact and injured spine with and without external stabilization.

OBJECT: The purpose of this study was to establish a cadaveric model for evaluating cervical spine motion in both the intact and injured states and to examine the efficacy of commonly used stabilization techniques in limiting that motion. METHODS: Intubation was performed in fresh human cadavers with intact cervical spines, following the creation of a C4-5 posterior ligamentous injury. Movement of the cervical spine during direct laryngoscopy and intubation was recorded using video fluoroscopy and examined under the following conditions: 1) without external stabilization; 2) with manual in-line cervical immobilization; and 3) with Gardner-Wells traction. Subsequently, segmental motion of the occiput through C-5 (Oc-C5) was measured from digitized frames of the recorded video fluoroscopy. The predominant motion, at all levels measured in the intact spine, was extension. The greatest degree of motion occurred at the atlantooccipital (Oc-C1) junction, followed by the C1-2 junction, with progressively less motion at each more caudal level. After posterior destabilization was induced, the predominant direction of motion at C4-5 changed from extension to flexion, but the degree of motion remained among the least of all levels measured. Traction limited but did not prevent motion at the Oc-C1 junction, but neither traction nor immobilization limited motion at the destabilized C4-5 level. CONCLUSIONS: Cadaveric cervical spine motion accurately reflected previously reported motion in living, anesthetized patients. Traction was the most effective method of reducing motion at the occipitocervical junction, but none of the interventions significantly reduced movement at the subaxial site of injury. These findings should be considered when treating injured patients requiring orotracheal intubation.

Aged↗

Effects of digitalis on sinus nodal function in patients with sick sinus syndrome.

The effect on sinus rhythmicity and automaticity of complete digitalization in a 24 hour period was observed in 14 patients with sick sinus syndrome. Sinus nodal function was evaluated in these patients by assessing sinus nodal recovery time and by treadmill exercise testing and 24 hour Holter monitoring, before and after digoxin administration. Corrected sinus nodal recovery times ranged from 240 to 2,065 msec (average 714) before digoxin and were shortened to 250 to 1,260 msec (average 565) after the glycoside. Further, digoxin induced accelerated infra sinus escape pacemaker activity in five patients: junctional and ventricular in one and atrial in four. Spontaneous sinus rate evaluated with Holter monitoring revealed an average of 56 beats/min (range 43 to 69) before digitalis that was unchanged (average 58 beats/min; range 48 to 74) after digoxin therapy. Similarly, the sinus nodal response to exercise was unaffected after digitalization (average 118 beats/min both before and during digitalis therapy). It is concluded that digoxin does not exert adverse effects on sinus nodal function in patients with sick sinus syndrome. The glycoside can be used safely in these patients when indicated for cardiac pump dysfunction or for control of tachyarrhythmia.

Adult↗