Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Clinical application”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14Linked to original sources

Filterability of blood cells: methods and clinical applications.

It could be claimed that expansion in clinical aspects of haemorheology has largely been fueled by the development of a simple test of blood flow properties, i.e., analysis of filterability. With time, the level of sophistication in equipment, theory and sample preparation has increased. Theories for the development of flow in the filter have been described and these enable cellular parameters, such as transit times, to be calculated from experimental data. These theories can be quite general, and applied to filtration of red or white cells. Ideally, experimental design requires an understanding of cell behaviour at the filter and of the effects of factors such as the sample concentration and volume, and the presence of different types of cells or subpopulations. Otherwise, results are susceptible to misinterpretation, particularly if impurities or mixed populations of cells are present. It is thus very important to know accurately the constituents of the test suspension. In clinical applications the trend has been to move away from whole blood filtration, toward use of relatively pure suspension of separated red cells and white cells. In the area of red cell filtration this has led to reappraisal of some previously reported abnormalities. The relatively new study of white cell filtration should benefit from previous experience, but there is the added problem of the reactivity of the cells under test, and their mixed nature. In any case, critical evaluation of the meaning and clinical relevance of results is necessary.

Blood Flow Velocity↗

[Preliminary clinical application of percutaneous vertebroplasty].

OBJECTIVE: To investigate the clinical application of percutaneous vertebroplasty (PVP). METHODS: PVP was performed in 21 cases of 37 vertebral lesions,including 14 osteoporotic compression fractures, 6 metastases, 1 hemangioma,and 17 lesions in thoracic vertebra and 20 in lumbar. The procedures of PVP were as follows: The needle was inserted via percutaneous transpedicular approach or percutaneous posterolateral vertebral approach; the needle tip was placed at the junction of the anterior located the one third of the vertebral body; intraosseous venography was performed; and last bone cement was injected at 2-10 mL. The technical success rate, clinical efficacy and complications were observed after the procedure. Results The procedure was successful in 18 cases with 31 lesions,and the success rate according to the number of cases and vertebral lesions was 85.7% (18/21) and 83.8% (31/37), respectively. After the procedure, the numbers of complete remission, partial remission, mild remission and no remission were 10, 5, 2 and 1, respectively; and the total effective rate was 94.4% (17/18). Progressive compression did not occur. Three patients had transient neuropathy and recovered after physiotherapy. Other complications were insignificant; no severe complications occurred. Conclusion PVP is an effective and micro-traumatic treatment for patients with benign and malignant lesions in vertebral bodies.

Adult↗

Clinical applications of diffusion tensor imaging.

Directionally-ordered cellular structures that impede water motion, such as cell membranes and myelin, result in water mobility that is also directionally-dependent. Diffusion tensor imaging characterizes this directional nature of water motion and thereby provides structural information that cannot be obtained by standard anatomic imaging. Quantitative apparent diffusion coefficients and fractional anisotropy have emerged from being primarily research tools to methods enabling valuable clinical applications. This review describes the clinical utility of diffusion tensor imaging, including the basic principles of the technique, acquisition, data analysis, and the major clinical applications.

Anisotropy↗

Spectral analysis: principle and clinical applications.

This review article describes the principle and clinical applications of spectral analysis. Spectral analysis provides a spectrum of the kinetic components which are involved in the regional uptake and partitioning of tracer from the blood to the tissue. This technique allows the tissue impulse response function to be derived with minimal modeling assumptions. Spectral analysis makes no a priori assumptions regarding the number of compartments or components required to describe the time course of tracer in the tissue. Spectral analysis can be applied to various dynamic data acquired by planar scintigraphy, single photon emission computed tomography (SPECT) or positron emission tomography (PET) as an alternative approach to compartment analysis. This analysis appears to be clinically useful, because it not only facilitates the interpretation of dynamic scintigraphic, SPECT or PET data, but also simplifies comparisons between regions and between subjects.

Algorithms↗

Monitoring of pulmonary endothelial enzyme function: an animal model for a simplified clinically applicable procedure.

The authors present a simple and clinically applicable method for the serial monitoring of pulmonary microvascular enzyme function in vivo. This method requires the intravenous injection of trace amounts of a radiolabelled substrate and the collection of a single arterial blood sample. Simultaneous measurement of pulmonary blood flow, (e.g., by dye- or thermo-dilution) and the determination of blood hematocrit are also needed for the calculations. This method was compared to the multiple blood sample indicator dilution method in normal anesthesized rabbits. Both methods gave identical results for the metabolism of the synthetic, hemodynamically inactive tripeptide, 3H-benzoyl-Phe-Ala-Pro (3H-BPAP), by pulmonary microvascular endothelial angiotensin converting enzyme. The parameters measured were: 1) substrate utilization, expressed linearly and logarithmically, and 2) the apparent first order reaction constant. The new method was also used for the simultaneous measurement of single pass, transpulmonary metabolism of 3H-BPAP by angiotensin converting enzyme and of 5'-adenosine monophosphate by 5'-nucleotidase in rabbits in vivo. The authors propose that similar enzyme kinetic measurements could be used in clinical studies to test their usefulness as an aid in the early diagnosis of incipient pulmonary endothelial dysfunction, e.g., adult respiratory distress syndrome.

5'-Nucleotidase↗

[Clinical application of allogeneic tendon].

OBJECTIVE: To explore the clinical application of allogeneic tendon handled by ultra-deep-low-temperature. METHODS: From March 1995 to June 2002, tendons rupture and tendons defect were repaired by ultra-deep-low-temperature allogeneic tendon grafts in 96 cases, including 51 cases of flexor or extensor tendon defect of hand, 36 cases of coracoclavicular ligament rupture, 4 cases of cruciate ligament rupture, 2 cases of calcaneus tendon rupture and 3 cases of extensor tendon defect of foot. The interval between injury and operation was 1 day to 5 months. The length of defect was 4-12 cm with an average of 7 cm. The matching allogeneic tendons were selected during operation, and early function exercise was done after operation. Secondary release was performed in the cases of tendon adhesion. RESULTS: Follow-up time is from 6 months to 5 years (3.4 years on average). No rejection or rupture occurred after tendon allograft. The satisfactory result was achieved in 92.71% of the cases. CONCLUSION: The allogeneic tendon is similar to auto-tendon in transplanting, healing and function is useful clinically.

Adolescent↗

Closed system generation of dendritic cells from a single blood volume for clinical application in immunotherapy.

Dendritic cells (DC) used for clinical trials should be processed on a large scale conforming to current good manufacturing practice (cGMP) guidelines. The aim of this study was to develop a protocol for clinical grade generation of immature DC in a closed-system. Aphereses were performed with the Cobe Spectra continuous flow cell separator and material was derived from one volume of blood processed. Optimisation of a 3-phase collection autoPBSC technique significantly improved the quality of the initial mononuclear cell (MNC) product. Monocytes were then enriched from MNC by immunomagnetic depletion of CD19+ B cells and CD2+ T cells and partial depletion of NK cells using the Isolex 300I Magnetic cell selector. The quality of the initial mononuclear cell product was found to determine the outcome of monocyte enrichment. Enriched monocytes were cultured in Opticyte gas-permeable containers using CellGro serum-free medium supplemented with GM-CSF and IL-4 to generate immature DC. A seeding concentration of 1 x 10(6) was found optimal in terms of DC phenotype expression, monocyte percentage in culture, and cell viability. The differentiation pattern favours day 7 for harvest of immature DC. DC recovery, viability, as well as phenotype expression after cryopreservation of immature DC was considered in this study. DC were induced to maturation and evaluated in FACS analysis for phenotype expression and proliferation assays. Mature DC were able to generate an allogeneic T-cell response as well as an anti-CMV response as detected by proliferation assays. These data indicate that the described large-scale GMP-compatible system results in the generation of stable DC derived from one volume of blood processed, which are qualitatively and quantitatively sufficient for clinical application in immunotherapeutic protocols.

Adoptive Transfer↗

Preliminary clinical application of contrast-enhanced MR portography.

The clinical application of contrast enhanced (CE) MR was evaluated. A total of 66 CE MR portograms were obtained by performing fast imaging with steady procession (FISP) technique on a 1.5-T Siemens magnetom vision. A maximum intensity projection algorithm was also employed to include all vessels in a single image. The patency of portal venous system, the presence and extent of varices were also evaluated. The results showed that all images had diagnostic quality. Main portal vein (MPV) and its 4th-6th level intrahepatic branches were visualized in 10 normal persons serving as control. The diameter of MPV, splenic vein and superior mesenteric vein was 1.02 +/- 0.21, 0.8 +/- 0.15, 0.8 +/- 0.26 cm respectively, which were significantly lower than that in portal hypertension patients (1.38 +/- 0.27, 1.26 +/- 0.18, 1.24 +/- 0.18 cm, respectively). In 23 preoperative cases of portal hypertension, dilated portal vein and tortuous enlarged splenic vein were found in 23 cases; esophageal and coronary varices in 12 and 19 cases, respectively. In 7 postoperative re-examined cases with portal hypertension, the flow velocity and flow of MPV were decreased in all cases and esophageal varices could still be observed in 3 cases. New vessels appeared in the great curvature of stomach in 2 cases. In 20 cases of liver carcinoma, occlusion of MPV or its intrahepatic branches were showed in 14, compression and dislocation of intrahepatic portal vein were found in 6. In other 6 cases, 2 were splenic venous thrombosis and 4 were tumors in the intestine or retro-peritoneum. It is concluded that three-dimensional CE MR portography is an accurate technique for evaluating the portal venous system. It is a reliable and noninvasive technique that can provide important information for the evaluation of patients' condition before TIPSS and liver transplantation.

Contrast Media↗

Correlating Streptococcus mutans with dental caries in young children using a clinically applicable microbiological method.

The present study used a clinically applicable microbiological method to correlate Streptococcus mutans counts and dental caries prevalence in young children. The study population consisted of 37 subjects, between 16 and 60 months of age. Using a sterile tongue depressor, samples of unstimulated saliva were obtained from subjects and inoculated onto elevated agar plates containing a selective medium. Plates were incubated anaerobically at 37 degrees C for 48 h. chi 2 and multiple regression analyses gave highly significant relationships (p less than 0.01) between dental caries prevalence and the number of S. mutans colonies.

Child, Preschool↗

[Clinical application and future prospect of neuroendoscopic surgery].

The clinical application and future prospect of neuroendoscopic surgery are described. In the historical trend, it is emphasized that the neuroendoscopic surgery has become one of the major or leading procedures in "minimally-invasive approaches" to the intracranial lesions. The presently-available instrument include procedures using an endoscope of three different types: rigid-rod, steerable/flexible-fiber-rod and semi-rigid-rod. To use a rigid-rod or fiber-rod scope, it is available to apply forceps, laser, a microballoon and other fine instruments. The indication for neuroendoscopic surgery has been expanded to almost all neurosurgical procedures, as "endoscope-assisted" procedures are applied more to micro neurosurgical procedures (endoscope-assisted microsurgery). The realistic indication for "pure neuroendoscopic surgery" includes reconstruction of cerebrospinal fluid (CSF) pathway such as third ventriculostomy, septostomy, foramen reconstruction, fenestration of septation; removal or biopsy of tumor/cystic lesion, mainly in the intraventricular regions; and removal of hematoma involving the cerebral parenchyma (intracerebral hematoma), ventricles/(intraventricular hematoma) or subdural space (subdural hematoma). The intraparenchymal or deep-seated intracisternal lesions can be the realistic indication for "pure neuroendoscopic surgery" when the instrument are further developed in future. Neuroendoscopic surgery will play a promising and major role in the "minimally-invasive neurological procedure" in the 21st century.

Brain↗

[Continuous recording of cardiac output volume with the OptiQ system--experiences with clinical application].

This report discusses initial experiences with the clinical application of continuous cardiac output measurement (OptiQ SvO2/CCO-System). The system was used in 9 intensive care patients suffering either global cardiac insufficiency or systemic inflammatory response syndrome. Continuous cardiac output measurement was recorded during a period of stable blood pressure conditions and compared with the results of the conventional thermodilution method (bolus technique) in these patients. Regression analyses yielded r = 0.523 (r2 = 0.274) for the "urgent" mode, r = 0.943 (r2 = 0.889) for the "fast" mode, r = 0.953 (r2 = 0.907) for the "fast filter" mode and r = 0.990 (r2 = 0.980) for the "normal" mode. Mean differences between the continuous and the bolus technique were calculated as -0.13 +/- 1.81 l/min for the "urgent" mode, -0.42 +/- 0.51 l/min for the "fast" mode, -0.14 +/- 0.48 l/min for the "fast filter" mode and -0.08 +/- 0.19 l/min for the "normal" mode. After a period of two days, the costs of the conventional bolus technique significantly exceeded those of continuous measurement. The expenses for the conventional thermodilution technique are largely determined by the frequency of application and, hence, by the personnel and laboratory costs. In our experience, easy component handling and stable measuring properties make this new method of continuous cardiac output monitoring a valuable method in the diagnose and care of patients who are critically ill.

Cardiac Output↗

CT virtual bronchoscopy: imaging method and clinical application.

OBJECTIVE: To evaluate the imaging method and clinical application of CT virtual bronchoscopy (CTVB). METHODS: Fifty-two patients with bronchial and pulmonary diseases were studied with CTVB. All patients underwent fiberoptic bronchoscopy and patients with lung cancers were confirmed pathologically. Lung cancer of center type was found in 46 patients, postoperative lung cancer in 4, tracheal adenoidcystic carcinoma in 1, and bronchial diverticulum in 1. CTVB was performed using Navigator Smooth software on the workstation (Advantage Windows 3.1, GE Medical Systems). Source images included slice thickness of 3 mm or 5 mm, pitch of 1.0 or 1.5, 1.0 mm or 2.0 mm interval (overlap more than 60%) reconstruction. RESULTS: CTVB could reveal vividly the tracheobronchial lumens, the cartilage rings, the carina and the left and right main bronchi, down to the fourth order of bronchial orifices, mimicing fiberoptic bronchoscopy. Among 46 patients with lung cancers of center type, fiberoptic bronchoscopy showed the masses in 45 patients and CTVB displayed the masses in 42. The sensitivity of CTVB was 93.3% and its accuracy was 93.5% (chi 2 = 1.33, 0.10 < P < 0.25). The tumors appeared as masses or nodules, causing bronchial stenosis (n = 35) or occlusion (n = 7). The bronchial rings near the masses were blurred, smooth or absent in contrast to the findings of fiberoptic endoscopy. Postoperative bronchial stump (n = 4) appeared to be smooth. Bronchial diverticulum exhibited a local concavity on CTVB and local protrusion on surface shadow display (SSD). CTVB could pass through the stenotic bronchi and detect the occlusive bronchi from the distal end. CONCLUSIONS: The sensitivity of CTVB in detecting bronchial masses was higher than that of fiberoptic bronchoscopy. Combined with multiplanar reconstruction (MPR) and CTVB can demonstrate the extraluminal extension of tumors. As a noninvasive examining method, however, CTVB is limited to observe mucosal abnormalities and to obtain histologic samples.

Adult↗

Clinical applications of free soleus and peroneal perforator flaps.

Clinical applications of two free lateral leg perforator flaps are described: a free soleus perforator flap that is based on the musculocutaneous perforator vessels from one of the three main arteries in the proximal lateral lower leg, and a free peroneal perforator flap that is based on the septocutaneous or direct skin perforator vessels from the peroneal artery in the distal and middle thirds of the lateral lower leg. The authors applied free soleus perforator flaps to 18 patients and free peroneal perforator flaps to five patients with soft-tissue defects. The recipient site was the great toe in 14 patients, the hand and fingers in five patients, the leg in two patients, and the upper arm and the jaw in one patient each. The largest soleus perforator flap was 15 x 9 cm, and the largest peroneal perforator flap was 9 x 4 cm. Vascular pedicle lengths ranged from 6.5 to 10 cm in soleus perforator flaps and from 4 to 6 cm in peroneal perforator flaps. All flaps, except for the flap in one patient in the peroneal perforator flap series, survived completely. Advantages of these flaps are that there is no need to sacrifice any main artery in the lower leg, and there is minimal morbidity at the donor site. For patients with a small to medium soft-tissue defect, these free perforator flaps are useful.

Accidents, Occupational↗

Clinical application of percutaneous transluminal angioscopy. Comparison of findings in percutaneous transluminal angioplasty, thrombolysis, thrombus-extraction and stent-application.

Since the introduction of ultrathin angioendoscopes into clinical application, it has been possible to subject the findings of conventional or digital angiography to objective verification. In dogs and in patients, this new angioscopic method for visualization of arteries without surgical intervention has been carried out. The approach is transfemoral. Endoscopy is combined with angiography and, when indicated, percutaneous transluminal angioplasty (PTA), thrombolysis, thrombus extraction and insertion of a new type of stent. An ultrathin endoscope with an outer diameter of 1.6 mm and a working channel of 0.35 mm is used. Guidewires, contrast media and drugs for local thrombolysis can be employed through this channel. The endoscope is placed in the region of interest under fluoroscopy and direct visualization is obtained by using 0.9% NaCl for decreasing blood flow. Image recording is achieved by video or high-speed camera. With this method, the intraluminal events of dilatation, recanalization, local lysis, stent application and thrombus extraction can be visualized.

Angioplasty, Balloon↗

Arterial and venous thrombus imaging using Ga-67 DFO-DAS-fibrinogen: its clinical applicability.

The purpose of this study was the clinical application of 67Ga-DFO-DAS-fibrinogen 67Ga-fibrinogen in normal volunteers and patients with arterial or venous therombus, or bypass graft. DFO-DAS-fibrinogen was available as a lyophilized product and easily labeled by simple mixing with 67Ga-fibrinogen solution (2 mCi/2 ml). Images were taken by a scintillation camera 72 hours after the venous injection of 67Ga-fibrinogen (2 mCi). Ga-67 fibrinogen accumulated well in the liver and kidney in normal volunteers at the early stage, and radioactivity in the kidney, lung, and heart decreased after noticeably after 48 hours postinjection. Ga-67 fibrinogen clearly visualized fresh and old arterial thrombi localized in the thorax or abdomen of all patients suffering aneurysm, and in occlusive bypass graft, contrary to past observations with labeled fibrinogen. In venous thrombus, with the pulmonary artery included, visualization was limited to fresh thrombi of up to one month old. No adverse side effects were observed in any case.

Aged↗

[Clinical applications of the radioimmunoassay of carcinoembryonic antigen].

The clinical applications of the radioimmunoassay evaluation of the carcinoembryonic antigen (CEA) are examined here, with special reference to the follow-up of patients undertaking radiotherapy for uterus cancers, portio and bladder cancers, whether after surgery of not. In addition the Authors point out the levels of negativity for every test method, so that the possible crossed reaction with CEA-like substances can be taken into account.

Antigens, Neoplasm↗

[Clinical application of cultured epithelium].

The author have done clinical application of cultured epithelium grafting since 1985. In this article, the results of auto- and allografting (patients: 365 cases) were reported. By the cultivation of epidermal cells, many amount of cultured epithelium could be obtained. Cultured autografts took well to the partial thickness wounds. Grafted sites healed promptly and histologically resembled normal skin. Disfigurement on the skin surfaces was well treated and improved by autografting. Full thickness wounds caused by burn or excision of congenital giant nevi were treated with cryopreserved allogeneic skin and fresh autologous cultured epithelium. The results showed good graft take and histology. Allogeneic cultured epithelium accelerated the wound healing on the grafted area. Thus, the autologous and allogeneic cultured epithelial grafting procedure is a promising treatment for many patients suffering from large skin wounds or disfigurement of skin surfaces.

Burns↗