Prostate cancer: prediction of extracapsular extension with endorectal MR imaging and three-dimensional proton MR spectroscopic imaging.

PURPOSE: To determine if the addition of three-dimensional (3D) proton magnetic resonance (MR) spectroscopic imaging to endorectal MR imaging helps diagnose extracapsular extension (ECE) of prostate cancer. MATERIALS AND METHODS: Endorectal MR imaging and 3D MR spectroscopic imaging were performed in 53 patients with prostate cancer before radical prostatectomy. MR imaging studies were evaluated by two independent readers unaware of histopathologic findings. The presence of ECE was graded on a five-point scale. At 3D MR spectroscopic imaging, cancer was diagnosed if the ratio of choline plus creatine to citrate was 2 or more SDs above normal. The accuracy of MR imaging alone was compared with that of combined MR imaging and 3D MR spectroscopic imaging, with use of the step-section histopathologic results as the standard of reference. RESULTS: For the less experienced reader, the addition of 3D MR spectroscopic imaging to MR imaging significantly improved accuracy (area under the receiver operating characteristic curve [Az] = 0.75 vs Az = 0.62, P < .05). For the more experienced reader, the addition improved accuracy but not significantly (Az = 0.86 vs Az = 0.78). The addition also reduced interobserver variability (Az = 0.86 vs Az = 0.75). CONCLUSION: The addition of 3D MR spectroscopic imaging to MR imaging improves accuracy for less experienced readers and reduces interobserver variability in the diagnosis of ECE of prostate cancer.

Cross-Sectional Studies↗

[Hard-copy (film) versus soft-copy (CRT) reading performance between compressed and uncompressed images: SOLs in abdominal CT images].

The objective of this study was to examine the feasibility of soft-copy (CRT) reading and suitable compression. Forty abdominal CT images with a space-occupying lesion (SOL) in liver and 40 normal images were selected for receiver-operating-curve (ROC) analysis. Each image was compressed by JPEG extended mode into 1/10 its original capacity, and then an expanded image was printed on film. Ten radiologists evaluated the presence of liver SOLs (primary and secondary tumors) on soft-copy (CRT) and hard-copy (film) images. Each radiologist reviewed four types of images (original and compressed hard-copy and original and compressed soft-copy images). Values of the area under the curve in the various ROC analyses were 0.858 (FILM) and 0.842 (CRT) for original images and 0.879 (FILM) and 0.846 (CRT) for compressed images. The results of ROC analysis showed better reading performance with hard-copy than soft-copy images, but the difference was not statistically significant. Compressed images showed a higher value (0.879) than original images (0.858), a difference that was statistically significant (p < 0.029) by the paired t-test but not by the jackknife method. The results indicate that soft-copy reading is a clinically acceptable alternative to hard-copy reading. We have had no difficulty in reading abdominal CT images compressed to 1/10 of the original size by the JPEG method. This study was supported in part by a grant from the Japanese Ministry of Health and Welfare.

Humans↗

[Myocardial imaging in patients with Kawasaki disease: exercise stress imaging and serial studies].

Thallium-201 myocardial imaging was performed in 80 children with coronary arterial lesions due to Kawasaki disease in order to assess the value of serial and exercise myocardial imagings. In eight of these children, abnormalities of the image were noted. Twenty children had serial thallium studies with an interval of three to 18 months, and five of these showed changes in the image including appearance of a new perfusion defect in one patient and improvement of perfusion defects in four. These changes of the myocardial image were correlated well with coronary angiographic findings obtained within a few days of the isotope studies. It was noted that the changes of the myocardial image were more frequently observed at relatively recent period recovered from Kawasaki disease. Exercise myocardial imaging using a bicycle ergometer was performed in eight children with coronary arterial lesions. In three an evidence of improvement of the myocardial perfusion was noted immediately after exercise as well as on the delayed image. In one patient, a decrease of the perfusion in the apex and inferior wall was noted immediately after exercise. On the observed image, image of the apex improved but that of the inferior wall remained hypoperfused. Thus thallium-201 myocardial imaging was considered to permit the best noninvasive documentation of ongoing myocardial perfusion abnormalities in patients with Kawasaki disease. Exercise myocardial imaging was found to be useful in differentiating the viable from nonviable myocardium. It was to be emphasized that quantitative evaluation by computer-assisted analysis was particularly valuable in detecting small areas and in a comparison of the myocardial images.

Adolescent↗

Segmentation of acoustic neuromas with magnetic resonance imaging and Eigen image filtering.

OBJECTIVE: This study aimed to determine whether magnetic resonance imaging with Eigen image filtering can segment acoustic neuromas as a preliminary requirement to the development and validation of a volumetric method of measuring tumor size and growth using Eigen image filtering. STUDY DESIGN: This was an observational study. SETTING: The study was performed in an academic, comprehensive multi-specialty group practice. PATIENTS: Patients were a convenience sample of adults of both sexes who had acoustic neuromas identified by magnetic resonance imaging. Tumors ranged widely in size. INTERVENTION: Magnetic resonance imaging with digital image analysis using Eigen image filtering was the intervention. MAIN OUTCOME MEASURE: Observation and analysis of magnetic resonance images was the main outcome measure. RESULTS: The ability of magnetic resonance imaging with Eigen image filtering to segment acoustic neuromas of various sizes and shapes is illustrated. CONCLUSIONS: Magnetic resonance imaging with digital image analysis using Eigen image filtering is a promising method for volumetric measurement of acoustic neuroma size and growth. The potential for acoustic neuromas to grow may be underestimated by linear methods because of their relative lack of precision and of the geometric error that occurs in representing the volumetric growth of a three-dimensional tumor as a linear diameter.

Adult↗

Gadobenate dimeglumine-enhanced liver MR imaging: value of dynamic and delayed imaging for the characterization and detection of focal liver lesions.

The aim of this study was to determine the value of delayed-phase imaging (DPI) of gadobenate dimeglumine (Gd-BOPTA)-enhanced MR imaging for the evaluation of focal hepatic tumors compared with precontrast imaging and early dynamic phase imaging. The MR images were obtained in 48 patients with 98 focal hepatic tumors. Three-dimensional gradient-echo (GRE) imaging obtained before and 30, 60, and 1 h after administration of 0.1 mmol/kg of gadobenate dimeglumine. Each image set was analyzed qualitatively (lesion detection, conspicuity, delineation, and enhancement pattern on DPI) and quantitatively [signal-to-noise ratio (SNR), tumor-liver contrast-to-noise ratio (CNR)]. Improved lesion-to-liver contrast during the dynamic phase imaging was observed compared with precontrast images. The DPI showed a homogeneous enhancement of liver parenchyma and distinctive enhancement features of focal liver lesions: metastases (85%) showed a target shaped enhancement, and hepatocellular carcinomas (HCCs) showed an inhomogeneous (58%) or homogeneous enhancement (21%). The DPI showed better performance for the detection of metastases than other images by increasing lesion delineation ( p<0.05). The absolute CNR of metastasis measured from periphery of the tumors on DPI was greater than precontrast and arterial phase imaging ( p<0.05). The Gd-BOPTA during both dynamic and delayed phases provides valuable information for the characterization of focal liver lesions, and furthermore, Gd-BOPTA-enhanced DPI contributed to the improved detection of liver metastasis compared to precontrast and early dynamic imaging.

Adult↗

MR imaging of the prostate at 3 Tesla: comparison of an external phased-array coil to imaging with an endorectal coil at 1.5 Tesla.

RATIONALE AND OBJECTIVES: To qualitatively compare the image quality of torso phased-array 3-Tesla (3T) imaging of the prostate with that of endorectal 1.5-Tesla imaging. MATERIALS AND METHODS: Twenty cases of torso phased-array prostate imaging performed at 3-Tesla with FSE T2 weighted images were evaluated by two readers independently for visualization of the posterior border (PB), seminal vesicles (SV), neurovascular bundles (NVB), and image quality rating (IQR). Studies were performed at large fields of view(FOV) (25 cm) (14 cases) (3TL) and smaller FOV (14 cm) (19 cases) (3TS). A comparison was made to 20 consecutive cases of 1.5-T endorectal evaluation performed during the same time period.Results. 3TL produced a significantly better image quality compared with the small FOV for PB (P = .0001), SV (P =.0001), and IQR (P = .0001). There was a marginally significant difference within the NVB category (P = .0535). 3TL produced an image of similar quality to image quality at 1.5 T for PB (P = .3893), SV (P = .8680), NB (P = .2684), and IQR (P = .8599). CONCLUSION: Prostate image quality at 3T with a torso phased-array coil can be comparable with that of endorectal 1.5-T imaging. These findings suggest that additional options are now available for magnetic resonance imaging of the prostate gland.

Adenocarcinoma↗

Detection of degradation of magnetic resonance (MR) images: comparison of an automated MR image-quality analysis system with trained human observers.

RATIONALE AND OBJECTIVES: The perceived need for magnetic resonance (MR) imaging quality control (QC) is occasionally minimized on the assumption that significant errors will be detected by the users. To evaluate the validity of this assumption, we compared the sensitivity of a test object and automated image analysis system for MR imaging QC with the sensitivity of trained human observers by evaluating images that were intentionally degraded. METHODS: Parameters for imaging the test object and normal human volunteers were set to values that decreased the signal-to-noise ratio (SNR), caused distortion, and increased the slice thickness and separation. RESULTS: The human observers were able to detect a 6-13% reduction in the SNR and distortions of more than 15% in human images. They were unable to identify 40% increases in the slice thickness. Automated analysis of test object images was able to detect all image degradations at the minimum levels applied. CONCLUSION: The poor sensitivity of the human observers indicated that degradation, especially spatial measurements, could be significantly in error before being detected through visual analysis of clinical images. These errors would be detected by automated analysis of the test object used. Further investigation is needed to better define the accuracy with which quantitative image-quality analysis predicts the effects of degraded image quality on the ability of human observers to detect subtle abnormalities in clinical images.

Contrast Sensitivity↗

Dynamic subtraction magnetic resonance imaging of cirrhotic liver: assessment of high signal intensity lesions on nonenhanced T1-weighted images.

PURPOSE: The purpose of this work was to determine the technical feasibility and value of dynamic subtraction (postcontrast-precontrast) magnetic resonance (MR) imaging for the assessment of hyperintense lesions on precontrast T1-weighted images in the cirrhotic liver. METHODS: One hundred four hyperintense lesions on T1-weighted precontrast and arterial phase postcontrast images were subjected to analysis of their subtraction qualities depending on the lesion size, location and/or the degree of misregistration between the source images in 27 different MR imaging sets. RESULTS: The quality of subtraction images was always diagnostic for lesions larger than 2 cm in diameter (n=8) but not diagnostic for 73% (40 of 55 lesions) of small subcentimetric lesions. Thirty-one subcapsular lesions always showed a variable degree of coregistration artifact. Only 3 of 35 lesions with a slice misregistration of 3 mm or more gave rise to subtraction images of diagnostic quality. For determining the contrast enhancement, the area under the receiver operating characteristic curve of 30 verified lesions was significantly larger (P <0.001) for subtraction images than for conventional arterial phase images. CONCLUSION: Depending on the lesion size and/or location or the degree of misregistration between the source images, dynamic subtraction MR imaging can be useful for the characterization of hyperintense lesions on precontrast T1-weighted imaging.

Adult↗

Arterial hyperintensity on fast fluid-attenuated inversion recovery images: a subtle finding for hyperacute stroke undetected by diffusion-weighted MR imaging.

BACKGROUND AND PURPOSE: Diffusion-weighted MR imaging is generally acknowledged to be more sensitive in detecting acute stroke than is conventional MR imaging. Our purpose in the present study was to evaluate the utility of fast fluid-attenuated inversion recovery (FLAIR) MR imaging compared with that of diffusion-weighted MR imaging for the diagnosis of hyperacute stroke. METHODS: We reviewed patient records and cerebral MR images from all patients in a 13-month period from whom diffusion-weighted and fast-FLAIR imaging were obtained within 6 hours after symptom onset (n = 11). Special attention was paid to the presence or absence of arterial hyperintensity on FLAIR images and abnormally high-signal regions on diffusion-weighted images in the affected vascular territories. RESULTS: Arterial hyperintensity was found in eight of 11 patients, all of whom had embolic or thrombotic infarctions with middle cerebral arterial (MCA) distribution. Arterial hyperintensity was negative in the remaining three patients; the vascular territories were the posterior circulation region in two of these patients and the MCA region in one, and the types of infarction in these same patients were lacunar in two and embolic in one. Regions with high-signal diffusion abnormalities relevant to the patients' symptoms were found in 10 of 11 patients. One patient showed no diffusion abnormalities but the presence of arterial hyperintensity in the affected MCA territory on the initial MR examination, and manifested embolic infarction along with arterial hyperintensity on the initial FLAIR image. CONCLUSION: Although diffusion-weighted MR imaging is highly sensitive to stroke, diffusion-weighted MR imaging alone may not rule out a possible infarction. Arterial hyperintensity on FLAIR images can precede diffusion abnormalities and may provide a clue to the early detection of impending infarction.

Aged↗

Head-to-head comparison of fundamental, tissue harmonic and contrast harmonic imaging with or without an air-filled contrast agent, levovist, for endocardial border delineation in patients with poor quality images.

Recent developments in tissue harmonic imaging and intravenous contrast agents have enhanced left ventricular endocardial border delineation (EBD). In a total of 48 patients with poor quality images, apical 4- and 2-chamber views were obtained with fundamental, tissue harmonic and contrast harmonic imaging with or without intravenous Levovist, an air-filled contrast agent. The left ventricle (LV) was divided into 12 segments, and the EBD of each segment was scored: (1) not visible, (2) barely visible, (3) well delineated. The EBD index (EBDI), defined as the sum of the endocardial scores divided by 12 was obtained for each patient. Of a total of 576 LV segments, 231 were scored as 1 by fundamental imaging and that number decreased to 125 segments by tissue harmonic imaging and 116 segments by fundamental imaging with Levovist. The number of segments scored as 1 decreased to 38 segments by tissue harmonic imaging with Levovist, and to 29 segments by contrast harmonic imaging with Levovist. The EBDI by fundamental imaging was 1.85+/-0.29, which improved significantly with the addition of Levovist (2.10+/-0.36, p<0.001) and was nearly identical to that by tissue harmonic imaging (2.15+/-0.32, p=NS). Tissue and contrast harmonic imaging with Levovist further enhanced the EBDI (2.43+/-0.26, 2.51+/-0.27, respectively). Levovist enhances EBD, even in the fundamental mode, to the level obtained with tissue harmonic imaging. Tissue harmonic and contrast harmonic imaging are the best modalities for enhancing EBD after Levovist injection.

Aged↗

Image transmission and data compression. Two key elements of an electronic imaging department.

Growing numbers of diagnostic images are being produced electronically and filmed only for storage, or sometimes also for interpretation. However, in most imaging centers, transmission of images from one location to another is still being accomplished manually. Almost 40 years ago, x-rays were first transmitted over telephone lines, and this form of "teleradiology" has been increasingly used to link isolated hospitals and clinics to larger facilities so that radiologists can interpret the images. Continuing improvement of the various electronic image-processing technologies has produced faster means of transmission, and increasingly sophisticated computer algorithms for "compressing" the image data have further improved both transmission speed and the quality of the transmitted images. To date, only a few imaging research centers and teaching hospitals have integrated these techniques into a comprehensive picture archiving and communications system (PACS) or digital image management system (DIMS), and a number of factors are restraining these systems' spread. However, electronic transmission of images for interpretation by specialists at a central facility is likely to increase, and truly "filmless" radiology may someday become a reality, if image transmission and data compression techniques are eventually determined to create images of acceptable quality in all imaging modalities.

Computer Communication Networks↗

Three-dimensional image registration of phantom vertebrae for image-guided surgery: a preliminary study.

OBJECTIVE: Applications of three-dimensional ultrasound (3D US) are emerging throughout the field of medicine. In this study, tracked, free-hand 3D phantom US images were mapped to computed tomograms (CT) as a development for image-guided surgery (IGS) of the spine. In the operating room, the registration of tracked 3D US images to other imaging modalities, such as CT, could allow the surgeon to identify more precisely the surgical target area prior to the incision. An independent quantitative measure of registration accuracy using a fiducial marker system was provided. METHODS: Three-dimensional free-hand US images of a phantom spine were created by tracking the transducer with an optical sensing system. Two sets of images were acquired from three lumbar vertebrae using 4.5- and 7.5-MHz transducers. These images were then segmented for the extraction of the posterior vertebral surface. Next, a surface-based registration of US to the corresponding segmented CT images was performed. Registration errors were computed as the distance between a set of target points transformed using the experimental transformation and the same set of target points transformed using fiducial markers as a gold standard. RESULTS: Results indicated that alignment of these image sets is feasible using only part of the vertebral surface. In particular, the regions of the spinous process and laminae were used for registration. Target registration errors (TREs) were found to be lowest using the highest resolution CT images. Using the CT scans with 2-mm slice thickness, the TRE was calculated to be 1.33 +/- 0.30 mm for the 7.5-MHz US data set and 2.81 +/- 0.10 mm for the 4.5-MHz US data set. Moreover, residual errors in these surface alignments were 0.69 +/- 0.18 mm and 0.61 +/- 0.20 mm for the 4.5- and 7.5-MHz sets, respectively. CONCLUSION: A rigid, surface-based registration of CT images to phantom spinal US images, acquired with a free-hand, tracked transducer, is achievable with a limited, easily obtainable portion of the vertebral surface.

Algorithms↗

Localization of ectopic parathyroid glands using technetium-99m sestamibi imaging: comparison with magnetic resonance and computed tomographic imaging.

The aim of the study was to compare the accuracy of technetium-99m sestamibi imaging for localization of ectopic parathyroid glands in patients with hyperparathyroidism with that of magnetic resonance (MR) and computed tomographic (CT) imaging. Eleven patients with primary (n=3) or secondary (n=8) hyperparathyroidism were studied with 99mTc sestamibi parathyroid imaging CT and MR imaging. Images of the neck were acquired at 10 min and 2-3 after tracer injection. The three patients with primary hyperparathyroidism and five patients with secondary hyperparathyroidism underwent parathyroidectomy. The ectopic glands were confirmed by histopathological examination of the resected specimens. In respect of 20 parathyroid glands in the eight patients explored surgically, the sensitivity and specificity of sestamibi imaging were 70% (14/20) and 88%, respectively, those of CT, 40% (8/20) and 88%, and those of MR imaging, 60% (12/20) and 88%. Of these patients, three had parathyroid adenomas while five had hyperplasia (17 glands). Sestamibi imaging localized eight ectopic parathyroid glands, which were surgically confirmed (six were located in the thymus and two in the mediastinum). In one patient explored surgically, the ectopic gland was located outside the field of the MR coil. Although the remaining three cases of secondary hyperparathyroidism were not confirmed surgically, these patients demonstrated sestamibi uptake in five parathyroid glands, including three ectopic glands. MR images demonstrated abnormal parathyroid glands in the same regions as sestamibi imaging. Our data indicate that 99mTc-sestamibi imaging should be used initially to localize the ectopic parathyroid glands in patients with hyperparathyroidism for anatomical guidance prior to MR or CT imaging.

Choristoma↗

Correction of nonuniform attenuation and image fusion in SPECT imaging by means of separate X-ray CT.

Improvements in image quality and quantitation measurement, and the addition of detailed anatomical structures are important topics for single-photon emission tomography (SPECT). The goal of this study was to develop a practical system enabling both nonuniform attenuation correction and image fusion of SPECT images by means of high-performance X-ray computed tomography (CT). A SPECT system and a helical X-ray CT system were placed next to each other and linked with Ethernet. To avoid positional differences between the SPECT and X-ray CT studies, identical flat patient tables were used for both scans; body distortion was minimized with laser beams from the upper and lateral directions to detect the position of the skin surface. For the raw projection data of SPECT, a scatter correction was performed with the triple energy window method. Image fusion of the X-ray CT and SPECT images was performed automatically by auto-registration of fiducial markers attached to the skin surface. After registration of the X-ray CT and SPECT images, an X-ray CT-derived attenuation map was created with the calibration curve for 99mTc. The SPECT images were then reconstructed with scatter and attenuation correction by means of a maximum likelihood expectation maximization algorithm. This system was evaluated in torso and cylindlical phantoms and in 4 patients referred for myocardial SPECT imaging with Tc-99m tetrofosmin. In the torso phantom study, the SPECT and X-ray CT images overlapped exactly on the computer display. After scatter and attenuation correction, the artifactual activity reduction in the inferior wall of the myocardium improved. Conversely, the incresed activity around the torso surface and the lungs was reduced. In the abdomen, the liver activity, which was originally uniform, had recovered after scatter and attenuation correction processing. The clinical study also showed good overlapping of cardiac and skin surface outlines on the fused SPECT and X-ray CT images. The effectiveness of the scatter and attenuation correction process was similar to that observed in the phantom study. Because the total time required for computer processing was less than 10 minutes, this method of attenuation correction and image fusion for SPECT images is expected to become popular in clinical practice.

Algorithms↗

Fast spectroscopic imaging of water and fat resonances to improve the quality of MR images.

RATIONALE AND OBJECTIVES: The authors evaluated whether fast spectroscopic imaging of water and fat resonances can produce high-quality anatomic magnetic resonance (MR) images of rodent tumors and human breast. MATERIALS AND METHODS: Fast MR spectroscopic images of eight rats with mammary tumors were acquired by using a 4.7-T MR unit equipped with self-shielded gradient coils. MR spectroscopic images of four human breasts were acquired with a 1.5-T MR unit. RESULTS: Artifacts due to eddy currents were minimal. Images synthesized from MR spectroscopic data, in which intensity was proportional to water signal peak height, were similar to T2-weighted MR images. Boundaries of rodent mammary tumors are similar but not identical on peak height-weighted and T2-weighted images. MR spectroscopic images of human breast showed improved detail compared to gradient-echo MR images. CONCLUSION: Preliminary results suggest that incorporation of fast MR spectroscopic imaging methods into many standard clinical MR imaging procedures may substantially improve image quality.

Adenocarcinoma↗

Pre-processed image reconstruction applied to breast and brain MR imaging.

Magnetic resonance imaging (MRI) has emerged as a powerful tool in medical diagnosis and research. Although high spatial resolution images are essential in medical diagnosis and image analysis, high temporal resolution is equally important in applications of dynamic contrast-enhanced MRI or functional brain MRI. In particular, in breast MRI the ability to differentiate between benign and malignant lesions depends, in part, on the temporal resolution of the dynamic image acquisition. New applications of MRI such as multi-feature analysis of image time series data and full 3D functional MRI or event-related functional MRI require high spatial and high temporal resolution for accurate image analysis on a voxel-by-voxel basis. Currently available partial Fourier reconstruction techniques. which effectively improve the time resolution, suffer from a reduced signal to noise ratio in the reconstructed image, a decrease in spatial resolution or reconstruction artefacts, making numerical image analysis difficult. In this work we present an image reconstruction algorithm based on image recovery theory which effectively doubles the temporal resolution and results in an image quality sufficient for further numerical analysis. The developed algorithm requires a full Fourier space acquisition of a pre-contrast or baseline image prior to the reconstruction procedure of the time series partial Fourier data.

Algorithms↗

Performance of electronic portal imaging devices (EPIDs) used in radiotherapy: image quality and dose measurements.

The aim of our study was to compare the image and dosimetric quality of two different imaging systems. The first one is a fluoroscopic electronic portal imaging device (first generation), while the second is based on an amorphous silicon flat-panel array (second generation). The parameters describing image quality include spatial resolution [modulation transfer function (MTF)], noise [noise power spectrum (NPS)], and signal-to-noise transfer [detective quantum efficiency (DQE)]. The dosimetric measurements were compared with ionization chamber as well as with film measurements. The response of the flat-panel imager and the fluoroscopic-optical device was determined performing a two-step Monte Carlo simulation. All measurements were performed in a 6 MV linear accelerator photon beam. The resolution (MTF) of the fluoroscopic device (f 1/2 = 0.3 mm(-1)) is larger than of the amorphous silicon based system (f 1/2 = 0.21 mm(-1)), which is due to the missing backscattered photons and the smaller pixel size. The noise measurements (NPS) show the correlation of neighboring pixels of the amorphous silicon electronic portal imaging device, whereas the NPS of the fluoroscopic system is frequency independent. At zero spatial frequency the DQE of the flat-panel imager has a value of 0.008 (0.8%). Due to the minor frequency dependency this device may be almost x-ray quantum limited. Monte Carlo simulations verified these characteristics. For the fluoroscopic imaging system the DQE at low frequencies is about 0.0008 (0.08%) and degrades with higher frequencies. Dose measurements with the flat-panel imager revealed that images can only be directly converted to portal dose images, if scatter can be neglected. Thus objects distant to the detector (e.g., inhomogeneous dose distribution generated by a modificator) can be verified dosimetrically, while objects close to a detector (e.g., a patient) cannot be verified directly and must be scatter corrected prior to verification. This is justified by the response of the flat-panel imaging device revealing a strong dependency at low energies.

Equipment Failure Analysis↗

Synthetic images by subspace transforms. I. Principal components images and related filters.

The principal component (PC) approach offers compressions of an image sequence into fewer images and noise suppressing filters. Multiple MR images of the same tomographic slice obtained with different acquisition parameters (i.e., with different TR, TE, and flip angles), time sequences of images in nuclear medicine, and cardiac ultrasound image sequences are examples of such input image sets. In this paper noise relationships of original and linearly transformed image sequences in general, and specifically of original, PC, and PC-filtered images are discussed. As the spinoff, it introduces locally weighted PC transforms and filters, nonlinear PC's, and a single-image based filter for suppression of noise. Examples illustrate increased perceptibility of anatomical/functional structures in PC images and PC-filtered images, including extraction of physiological functional information by PC loading curves. Generally, the more correlated the original images are, the more effective is the PC approach.

Diagnostic Imaging↗