Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “dynamic range”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13Linked to original sources

Extracellular calcium controls the dynamic range of neuronal metabotropic glutamate receptor responses.

The metabotropicglutamate receptors (mGluRs) are neurotransmitter receptors important for synaptic plasticity in the brain. Here we report that native mGluR-mediated neuronal responses to glutamate are profoundly modulated by extracellular calcium (Ca2+(o)). In mouse cerebellar Purkinje cells (PCs), Ca2+(o) drastically broadened the effective dose range for glutamate analogs in which native mGluR1-mediated cation current and intracellular Ca2+ mobilization were evoked. This effect has not been observed for recombinant mGluRs expressed in the heterologous cell systems. Ca2+(o) also drastically augmented these native mGluR-mediated responses to the glutamate analog. These Ca2+(o) effects were observed in both the wild-type mice and the mutant mice expressing mGluR1 specifically in their PCs, suggesting that the native mGluR1 in the PCs but not those in other cell types are the key mediators of the effects. These findings demonstrate that Ca2+(o) plays an important role in regulating native mGluR-mediated neuronal responses.

Animals↗

Nerve injury-induced changes in opioid modulation of wide dynamic range dorsal column nuclei neurones.

In the present study we investigated the effects of spinal morphine on the electrically and naturally evoked responses of gracile nuclei neurones in a rat model of neuropathy, induced by the tight ligation of lumbar L5/6 spinal nerves. Two weeks after surgery, animals were prepared for electrophysiological recordings and neuronal responses were characterised to a range of controlled natural (brush, low- and high-intensity von Frey filaments, heat 45 degrees C) and peripheral electrical stimuli. Morphine (0.1, 0.25, 1 and 5 microg) was applied spinally and its effect was compared to that in sham-operated or naive animals. Following surgery, all neuropathic rats exhibited signs of mechanical allodynia. Nerve injury induced a significant increase in the receptive field size of gracile nuclei neurones, and also produced a non-significant increase in the proportion and level of spontaneous activity in these neurones. The baseline electrical and natural evoked responses remained unaltered. Spinal morphine reduced both the Adelta-fibre- and C-fibre-evoked responses of gracile nuclei neurones, and similarly inhibited the heat-evoked responses of neuropathic, sham-operated and naive rats. Morphine, however, produced only minor reductions (<30% inhibition of pre-drug control responses) of the Abeta-fibre- and brush-evoked responses of gracile nuclei neurones. These drug effects were similar in all animal groups. In complete contrast, morphine produced a marked inhibition of the low-intensity punctate mechanical evoked responses (von Freys 2 and 9 g) after nerve injury, an effect that was totally lacking in the sham-operated or naive animal groups. This dramatic shift was selective for the low-intensity punctate mechanical stimuli and such an effect was not seen with the noxious mechanical punctate stimulus (von Frey 75 g) where there was a modest inhibition in all groups. Our results suggest that there is plasticity in the opioid modulation of dorsal column projection pathways following spinal nerve ligation and these alterations appear to interact with sensory pathways conveying low-threshold punctate stimuli.

Analgesics, Opioid↗

Dynamic range expansion applied to mass spectrometry based on data-dependent selective ion ejection in capillary liquid chromatography fourier transform ion cyclotron resonance for enhanced proteome characterization.

The characterization of cellular proteomes is important for understanding biochemical processes ranging from cell differentiation to cancer development. In one highly promising approach, whole protein extracts or fractions are digested (e.g., with trypsin) and injected into a packed capillary column for subsequent separation. The separated peptides are then introduced on-line to an electrospray ionization source of a Fourier transform ion cyclotron resonance (FTICR) mass spectrometer for the detection of peptide accurate mass tags that serve as biomarkers for their parent proteins. In this work, we report the use of data-dependent selective external ion ejection in conjunction with FTICR and on-line capillary LC separations for the enhanced characterization of peptide mixtures and a yeast extract proteome. The number of peptides identified in an LC-FTICR analysis of a yeast proteome digest employing data-dependent rf-only dipolar ejection of the most abundant ion species prior to ion accumulation was 40% higher than that detected in a separate LC-FTICR analysis using conventional nonselective ion accumulation.

Chromatography, Liquid↗

An experimental study of membrane materials and inner contacting layers for ion-selective K+ electrodes with a stable response and good dynamic range.

The goal was to identify formulations for use in valinomycin K(+) ion-selective electrodes that could routinely achieve a detection limit of <10(-6) M, even after repeated use and exposure at higher K+ activity (0.1 M) and without the requirement for special pretreatment or conditioning in low K+ activity (10(-3) M). Electrodes that would be characterized by high potential stability were sought in this work. Valinomycin-containing membranes with diffusion coefficient of approximately 10(-11) cm(2) s(-1), formulated from methacrylic/acrylic polymers with or without plasticizer, were compared with plasticized PVC membranes (diffusion coefficient 10(-8) cm(2) s(-1)). The methacrylic/acrylic membranes without plasticizer were shown to give an order of magnitude lower detection limit, when compared with PVC-dioctyl sebacate and o-nitrophenyl octyl ether plasticized methacrylic/acrylic polymers under the same conditions, highlighting the influence of plasticizer on the detection limit. As predicted from current theoretical derivation, the inner contacting layer in the ion-selective electrode construction was shown to be highly influential in maintaining the detection limit below 10(-6) M with use and with poly(pyrrole) providing the inner contact ion-to-electron transduction function, a further order of magnitude improvement in the lower detection limit could be maintained for both chloride and hexacyanoferrate doped poly(pyrrole), when 2% ionophore was employed in the ion-selective membrane. This formulation showed extraordinary stability and reproducibility in terms of measurement range and drift over extended measurement testing, with close to Nernstian slopes. At higher ionophore concentrations (4%), the apparent selectivity of the electrode was improved at the expense of detection limit and the nature of the poly(pyrrole) dopant ion became important in determining the dominant exchange processes at the poly(pyrrole)/ion-selective membrane interface.

Journal Article↗

Improving the sensitivity and dynamic range of reagentless fluorescent immunosensors by knowledge-based design.

The variable fragment (Fv) of an antibody can be transformed into a reagentless fluorescent biosensor by mutating a residue into a cysteine in the neighborhood of the paratope (antigen-binding site) and then coupling an environment-sensitive fluorophore, e.g., N-((2-(iodoacetoxy)ethyl)-N-methyl)amino-7-nitrobenz-2-oxa-1,3-diazole (IANBD ester), to the mutant cysteine. For some residues, named operational, the formation of the conjugate does not affect the affinity of the Fv fragment for the antigen, and the binding of the antigen generates a measurable variation in the fluorescence intensity of the conjugate. We tested if this signal variation could be increased by coupling several molecules of fluorophores to the same molecule of Fv. Seven operational residues have been previously identified in the single-chain Fv (scFv) of monoclonal antibody D1.3 (mAbD1.3), directed against lysozyme. Ten double mutants of scFvD1.3, involving these residues, were constructed and coupled to the IANBD ester. The fluorescence of the double conjugates revealed a transfer of resonance energy between the two identical fluorescent groups. This homotranfer could be more important in the free state of the conjugate than in its antigen-bound state and increase its sensitivity for the detection of the antigen by up to 2.9-fold. A poorly sensitive conjugate could be improved by coupling a second molecule of fluorophore to residues located far from the paratope. Mutations altering the affinity of scFvD1.3 for lysozyme were introduced into one of its fluorescent conjugates. Using a mixture of three mutant derivatives of this unique conjugate, we could titrate lysozyme with precision in a concentration range encompassing 3 orders of magnitude.

Binding Sites↗

Zinspy sensors with enhanced dynamic range for imaging neuronal cell zinc uptake and mobilization.

Thiophene moieties were incorporated into previously described Zinspy (ZS) fluorescent Zn(II) sensor motifs (Nolan, E. M.; Lippard, S. J. Inorg. Chem. 2004, 43, 8310-8317) to provide enhanced fluorescence properties, low-micromolar dissociation constants for Zn(II), and improved Zn(II) selectivity. Halogenation of the xanthenone and benzoate moieties of the fluorescein platform systematically modulates the excitation and emission profiles, pH-dependent fluorescence, Zn(II) affinity, and Zn(II) complexation rates, offering a general strategy for tuning multiple properties of xanthenone-based metal ion sensors. Extensive biological studies in cultured cells and primary neuronal cultures demonstrate 2-{6-hydroxy-3-oxo-4,5-bis[(pyridin-2-ylmethylthiophen-2-ylmethylamino)methyl]-3H-xanthen-9-yl}benzoic acid (ZS5) to be a versatile imaging tool for detecting Zn(II) in vivo. ZS5 localizes to the mitochondria of HeLa cells and allows visualization of glutamate-mediated Zn(II) uptake in dendrites and Zn(II) release resulting from nitrosative stress in neurons.

Animals↗

Differences in levels of heterozygosity in populations of the common gudgeon (Gobio gobio, Cyprinidae) among adjacent drainages in Central Europe: an effect of postglacial range dynamics?

Twenty-nine allozyme loci analyzed in 295 common gudgeons (Gobio gobio) from the Rhine, the upper Danube and the Elbe river systems revealed variability measures of P = 0.590, H(e) = 0.066, and G(ST) = 0.1415. Gene flow was estimated at N(e)m = 1.88 over 223 river km in the Danube basin, and at N(e)m = 1.96 over 300 river km in the Rhine system. Isolation-by-distance was not observed. Danubian gudgeons proved significantly more heterozygous (H(e) = 0.106) than those from the Rhine (H(e) = 0.057) or the Elbe drainages (H(e) = 0.029). Nine polymorphic enzymes contributed to this difference, which probably indicates dispersal bottlenecking of the postglacial immigrants into the Atlantic drainages of the study area. Refugial bottlenecking of gudgeons from Atlantic drainages in a Pleistocene refuge located in oceanic northwest Europe also seems possible. Slightly deeper genetic lineages in the Danube (G(ST) = 0.0859) than in the Rhine (G(ST) = 0.0793) agree with this explanation, as does the greater mean genetic distance among pairs of population samples from the Danube (D = 0.0138) than from the Rhine (D = 0.0054). A genetic distance of D = 0.0085 separated Rhenish and Danubian gudgeons.

Animals↗

Extending the dynamic range of fibre length and fibre aspect ratios by automated image analysis

An automatic image analysis system has been developed, that is capable of scanning a large sample area (70 mm x 70 mm) using transmitted light microscopy. The analysis, based on transparent algorithms, successfully discriminates between overlapping and touching fibres, so that sample preparation time is minimized. The system utilizes overlapping image frames to reconstruct partial fibre images and impart unique fibre length information in the range micrometres to millimetres. The software has been made adaptable to enable the accurate measurement of fibre lengths for fibres that curve over many millimetres. Data are presented illustrating the accurate measurement of fibre lengths over a large range of fibre aspect ratios.

Journal Article↗

Reliability and validity of active, passive and dynamic range of motion tests.

The purposes of this project were to determine (a) the reliability of ROM and POM assessment methods for tests where an ankle joint brace was used and (b) the relationship between active and passive ROM and POM inversion measurements. The range of motion of the ankle joint complex for inversion was quantified using a range of motion apparatus. The inversion path of motion for the foot and the shoe was quantified using a high speed video system. The results of this study indicated: (a) Comprehensive functional tests of ankle joint braces using ROM and POM measurements showed maximal group differences of less than 1 degree between days for ROM (rAROM = 0.96 and rPROM = 0.93) and less than 1.5 degrees for POM measurements (rPOM = 0.88). (b) PROM measurements showed a consistent "creep" effect of about 2 degrees with increasing trial number during the first ten trials which must be taken into consideration for the design of the appropriate test protocol. (c) The correlation coefficient between AROM and POM was 0.37 and 0.44 between PROM and POM, suggesting that AROM and PROM measurements do not predict inversion during actual movement.

Adult↗

Multifractal analysis of wide dynamic range neuron discharge profiles in normal rats and in rats with sciatic nerve constriction.

Using normal rats and rats with a chronic constriction injury of the sciatic nerve (injured, model of Bennett-Xie) we investigated the possibility of classifying, by statistical tools, the temporal sequences of neuronal discharges during different noxious and non-noxious stimuli. An analysis was made of both the distribution of the inter-spike intervals and the temporal density of spike trains, the latter being studied within the framework of stochastic universal multifractals, to allow the identification of different random processes involved in the discharge distributions through the Lévy index alpha. The statistical analysis shows that the parametrization based on the Lévy index seems able to discriminate between different noxious stimuli (mechanical pinching and thermal), both in normal and injured animals. Furthermore, comparing normal and injured animals, although the spontaneous basal and non-noxious stimuli (brushing) evoked activities presented different frequencies, these seem to have the same multifractal structure, while the corresponding statistics of the inter-spike intervals are quite different. This information might be relevant to the understanding of a code of neuronal firing and to the modelling of temporal patterns in acute and chronic noxious signals.

Algorithms↗

The effect of multi-channel wide dynamic range compression, noise reduction, and the directional microphone on horizontal localization performance in hearing aid wearers.

This study examined the effect that signal processing strategies used in modern hearing aids, such as multi-channel WDRC, noise reduction, and directional microphones have on interaural difference cues and horizontal localization performance relative to linear, time-invariant amplification. Twelve participants were bilaterally fitted with BTE devices. Horizontal localization testing using a 360 degrees loudspeaker array and broadband pulsed pink noise was performed two weeks, and two months, post-fitting. The effect of noise reduction was measured with a constant noise present at 80 degrees azimuth. Data were analysed independently in the left/right and front/back dimension and showed that of the three signal processing strategies, directional microphones had the most significant effect on horizontal localization performance and over time. Specifically, a cardioid microphone could decrease front/back errors over time, whereas left/right errors increased when different microphones were fitted to left and right ears. Front/back confusions were generally prominent. Objective measurements of interaural differences on KEMAR explained significant shifts in left/right errors. In conclusion, there is scope for improving the sense of localization in hearing aid users.

Adult↗

Development and application of a long dynamic range nitrous oxide monitoring system.

The laboratory and field evaluation of a nitrous oxide monitor for an extremely wide range of cumulative exposures are reviewed. The passive sampling behavior and high analyte capacity show it to be useful for short-term and full workweek exposure monitoring. The monitor has application for both area and personnel surveillance. The principal criterion is for an accurate report of exposure time of the monitor. Application of the monitor to real workplace environments--with and without a reference method--demonstrated the ability of workweek monitoring as a valuable and potentially superior way of documenting exposure stress of employees. Environmental factors such as humidity and temperature variation are shown to have acceptably small effects on both short- and long-term exposure data; barometric pressure affects the data in a predictable manner. Paired dosimeters show good agreement in the workplace environment throughout the range of 6-40 cumulative hours of exposure. In both hospital and dental operating suites, work logistics and work group relationships were readily traceable on a week-by-week basis during a continuous weekly monitoring program. Source emissions and appropriate worker and work area exposure relationships were clearly evident, with appropriate reduction of all exposures as a result of an abbreviated work schedule. The ability to effectively track employee and area exposure excursions in an integrated weekly manner leads to a whole series of new applications and concepts of industrial hygiene surveillance. Such approaches could effectively replace the speculative statistical approaches currently in use with actual data on a cost effective basis.

Air Pollutants, Occupational↗