Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “ULTRASONICS”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13Linked to original sources

Growth inhibition of Cyanobacteria by ultrasonic radiation: laboratory and enclosure studies.

The growth of Microcystis aeruginosa UTEX 2388 was repressed by ultrasonic radiation and resulted in an increased chlorophyll a content and cell size, suggesting the inhibition of cell division. However, growth was recovered immediately after the interruption of ultrasonication. In addition to the disruption of gas vesicles, other mechanisms of growth inhibition were also investigated. Although free radicals were produced by ultrasonication and hydrogen peroxide, the resulting lipid peroxidation in the cells was not comparable, indicating minimal damage by the free radicals. Ultrasonic radiation late in the day was found to be most effective in reducing the growth rate of M. aeruginosa, and this timing also corresponded to the phase of daily cell division. In an enclosure experiment, ultrasonic radiation reduced the pH, DO, total nitrogen, and total phosphorus, whereas it increased the water temperature, conductivity, and orthophosphate concentration. The algal cell density and chlorophyll a concentration drastically decreased after 3 d of ultrasonication, plus the cyanobacterial proportion was selectively reduced as compared to other algal species. Accordingly, ultrasonic radiation would appear to have considerable potential as an effective control method for cyanobacterial blooms.

Chlorophyll↗

Ultrasonically induced opening of polyelectrolyte microcontainers.

The effect of ultrasonic treatments of different intensity and duration on the integrity and permeability of polyelectrolyte capsules was investigated both in poly(allylamine)/poly(styrene sulfonate) and Fe(3)O(4)/poly(allylamine)/poly(styrene sulfonate) polyelectrolyte capsules. Ultrasonic treatment of polyelectrolyte capsules induces the destruction of the polyelectrolyte shell and the release of the encapsulated material even at short (5 s) sonification times. The presence of magnetite nanoparticles significantly improves the efficiency of the ultrasonically stimulated release of the encapsulated compounds and enables magnetically controlled delivery to the desired site before ultrasonic treatment. Release of the encapsulated compound induced at ultrasonic power comparable to those of ultrasonic generators applied in medicine, demonstrating practical application of the ultrasonically triggered capsule opening in medicine.

Allylamine↗

Ultrasonic nebulization of cationic lipid-based gene delivery systems for airway administration.

PURPOSE: This study relates to the development of gene therapies for the treatment of lung diseases. It describes for the first time the use of ultrasonic nebulization for administration of plasmid/lipid complexes to the lungs to transfect lung epithelial cells. METHODS: Plasmid complexed to cationic liposomes at a specific stoichiometric ratio was nebulized using an ultrasonic nebulizer. We assessed: (i) the stability of plasmid and plasmid/lipid complexes to ultrasonic nebulization, (ii) the in vitro activity of plasmid in previously nebulized plasmid/lipid complex, (iii) the in vivo transgene expression in lungs following intratracheal instillation of nebulized plasmid/lipid formulations compared to un-nebulized complexes, (iv) the emitted dose from an ultrasonic nebulizer using plasmid/lipid complexes of different size, and (v) the transgene expression in lungs following oral inhalation of aerosolized plasmid/lipid complex generated using an ultrasonic nebulizer. RESULTS: Integrity of plasmid formulated with cationic lipids, and colloidal stability of the plasmid/lipid complex were maintained during nebulization. In contrast, plasmid alone formulated in 10% lactose was fragmented during nebulization. The efficiency of transfection of the complex before and after nebulization was comparable. Nebulization produced respirable aerosol particles. Oral exposure of rodents for 10 minutes to aerosol produced from the ultrasonic nebulizer resulted in transgene expression in lungs in vivo. CONCLUSIONS: The performance characteristics of the ultrasonic nebulizer with our optimized plasmid/lipid formulations suggests that this device can potentially be used for administering gene medicines to the airways in clinical settings for the treatment of respiratory disorders.

Aerosols↗

Cervical tooth wear and sensitivity: erosion, softening and rehardening of dentine; effects of pH, time and ultrasonication.

BACKGROUND: Cervical dentine wear is commonly observed and may be associated with dentine hypersensitivity. Erosion is thought to play a part in both conditions but compared to enamel has been little studied in dentine. AIM: The aims of these studies in vitro were to: (i) determine the effects of citric acid on dentine at different pH values and over time; (ii) measure the depth of dentine demineralisation or softening using ultrasonication; (iii) determine whether softened dentine can be remineralised or rehardened using artificial saliva. METHODS: Groups of flat dentine specimens prepared from unerupted human third molar teeth were: (a) exposed to citric acid at pH 3.2 for periods up to 4 h with mineral water as control; (b) exposed to citric acid at pH 2.54, 3.2, 4.5, 5.5 and 6.0 for 2 h and then subjected to ultrasonication stepwise up to 480 s; (c) exposed to citric acid at pH 2.54, 3.2, and 4.5, placed into artificial saliva for 24 h and then subjected to ultrasonication as in (b). Loss of dentine was measured by profilometry, after, each phase of erosion, ultrasonication and immersion in artificial saliva. RESULTS: Depth of erosion significantly increased non-linearly with time and significantly decreased with increasing pH. Ultrasonication had minimal albeit significant effects on control specimens. Removal of softened dentine increased with ultrasonication time. Depth of softening significantly increased with increasing erosion time to 2 h, plateauing at 2 microm. Depth of softening increased to 2 microm from pH 2.54 to pH 3.2 and decreased at higher pH values thereafter. 24 h in artificial saliva provided no protection to the soften zone against ultrasonicaion. Citric acid at all pH values and exposure times removed the dentine smear layer to expose tubules. Ultrasonication did not remove the smear layer on control specimens but removed all deposits formed after exposure to artificial saliva. CONCLUSION: It is concluded that dentine is susceptible to erosion even at relatively high pH, the tubule system is readily exposed and dentine, unlike enamel, shows little propensity to remineralise.

Analysis of Variance↗

In vitro evaluation of Er:YAG laser scaling of subgingival calculus in comparison with ultrasonic scaling.

The purpose of the present study was to evaluate the effectiveness of Er:YAG laser scaling and the morphological and histological changes of the laser-scaled root surface in comparison with the effectiveness and root surface changes produced by conventional ultrasonic scaling. Fifty-three periodontally involved human extracted teeth with a band of subgingival calculus were used. The teeth were divided randomly into 2 groups for laser scaling and ultrasonic scaling. Laser irradiation was performed at an energy output of 40 mJ/pulse and 10 pulses/s under water spray, with the probe tip contacted obliquely to the root surface. Ultrasonic scaling was performed at a clinically standard power setting. The time required for scaling, the scaled area and the temperature changes were determined using both methods of treatment. The features of the scaled surfaces were examined by histological and scanning electron microscope (s.e.m.) observations. The Er:YAG laser provided subgingival calculus removal on a level equivalent to that provided by the ultrasonic scaler, without major thermal elevation. Macroscopically, the laser-treated root surface was somewhat rougher than or similar to the ultrasonically scaled root. However, the efficiency of the laser scaling was lower than that of the ultrasonic scaling. In addition, histological examination revealed a thin deeply stained zone on the lased root surface, and s.e.m. analysis revealed a characteristic microroughness on the lased surface. The laser scaling provided a level of calculus removal that was similar to that provided by the ultrasonic scaling. However, the Er:YAG laser produced superficial, structural and thermal microchanges on the root cementum.

Dental Calculus↗

Ultrasonic communication in frogs.

Among vertebrates, only microchiropteran bats, cetaceans and some rodents are known to produce and detect ultrasounds (frequencies greater than 20 kHz) for the purpose of communication and/or echolocation, suggesting that this capacity might be restricted to mammals. Amphibians, reptiles and most birds generally have limited hearing capacity, with the ability to detect and produce sounds below approximately 12 kHz. Here we report evidence of ultrasonic communication in an amphibian, the concave-eared torrent frog (Amolops tormotus) from Huangshan Hot Springs, China. Males of A. tormotus produce diverse bird-like melodic calls with pronounced frequency modulations that often contain spectral energy in the ultrasonic range. To determine whether A. tormotus communicates using ultrasound to avoid masking by the wideband background noise of local fast-flowing streams, or whether the ultrasound is simply a by-product of the sound-production mechanism, we conducted acoustic playback experiments in the frogs' natural habitat. We found that the audible as well as the ultrasonic components of an A. tormotus call can evoke male vocal responses. Electrophysiological recordings from the auditory midbrain confirmed the ultrasonic hearing capacity of these frogs and that of a sympatric species facing similar environmental constraints. This extraordinary upward extension into the ultrasonic range of both the harmonic content of the advertisement calls and the frog's hearing sensitivity is likely to have co-evolved in response to the intense, predominantly low-frequency ambient noise from local streams. Because amphibians are a distinct evolutionary lineage from microchiropterans and cetaceans (which have evolved ultrasonic hearing to minimize congestion in the frequency bands used for sound communication and to increase hunting efficacy in darkness), ultrasonic perception in these animals represents a new example of independent evolution.

Acoustic Stimulation↗

Effect of marrow on the high frequency ultrasonic properties of cancellous bone.

A number of investigators have performed in vitro measurements of cancellous bone to determine how various ultrasonic parameters depend on bone density and trabecular orientation. To facilitate handling and storage of bone specimens, the marrow is often removed prior to ultrasonic measurements. However, the assumption that marrow does not affect ultrasonic measurements at high frequencies (>1 MHz) has not been tested. The goal of this study is to determine the effect of marrow on the ultrasonic properties of bovine cancellous bone at frequencies greater than 1 MHz. Twelve specimens of cancellous bone were obtained from the proximal end of four bovine tibia. Ultrasonic measurements consisting of normalized broadband ultrasonic attenuation (nBUA), speed of sound (SOS) and apparent integrated backscatter (AIB) were measured in each specimen using 2.25 MHz (centre frequency) broadband ultrasonic pulses. These measurements were performed before and after marrow removal either along the superoinferior (SI) or mediolateral (ML) direction. SOS and nBUA showed no significant difference (p > 0.05) for either direction of propagation after marrow removal. AIB showed no significant difference in the SI direction. For the ML direction, a small but statistically significant difference (p = 0.044) was observed after marrow removal.

Animals↗

Comparison of two ultrasonic instruments for post removal.

The relative performance of two different ultrasonic units commonly used clinically for post removal was evaluated using tips designed specifically for post vibration. Twenty-four extracted maxillary and mandibular cuspids with crowns removed at the labial cementoenamel junction were treated endodontically. Post spaces were made 10 mm into the roots before cementing a 16 mm #5 (0.050-inch) Para-Post with zinc phosphate cement. The teeth were divided into three similar groups of eight. Post retention was assessed in group 1. Ultrasonic vibration was applied to groups 2 and 3 until post removal. The average force required to dislodge the posts from the teeth in group 1 (control group, no ultrasound) was 40.5 kg (SD = 12.3 kg). The average time for post removal in group 2 (Spartan) was 4:52 min (SD = 2:26). The average time for post removal in group 3 (Enac) was 1:31 min (SD = 0:34). The difference between groups 2 and 3 was statistically significant (p < 0.005). Use of ultrasonic tips designed for post vibration and maximization of audible sound level during ultrasonic treatment of posts seem to play an important role in the effectiveness and efficiency of post removal. The results obtained indicate that both the Enac ultrasonic unit with the ST-09 vibration tip and the Spartan ultrasonic unit with the Analytic VT-S tip were effective. Nevertheless, the Enac ultrasonic unit with the ST-09 vibration tip was clearly more efficient under these study conditions, resulting in typical post removal times of <2 min.

Cementation↗

Effects of steel scalpel, ultrasonic scalpel, CO2 laser, and monopolar and bipolar electrosurgery on wound healing in guinea pig oral mucosa.

OBJECTIVE: The study's objective was to compare instrument performance and tissue healing when steel scalpel, ultrasonic scalpel, monopolar or bipolar electrosurgical instruments, or CO2 laser was used in an animal oral surgery model. STUDY DESIGN: Prospective, blinded, randomized. METHODS: Adult guinea pigs (N = 70) were randomly assigned to 5 groups (14 animals per group) for excision of 2-cm, full-thickness oral mucosa using steel scalpel, ultrasonic scalpel, monopolar or bipolar electrosurgical instruments, or CO2 laser. Postoperative pain was measured indirectly using weekly body weight changes. Animals from each group were killed on days 0, 7, 14, 21, and 28. Specimens were harvested for blinded histopathological study and tensile strength measurement. Instrument performance (hemostasis, tissue coagulation, tissue sticking) and wound healing (tissue re-epithelialization, degree of inflammation) were primary outcomes. Statistical analysis was performed using analysis of variance. RESULTS: The ultrasonic scalpel was the best tool in controlling hemostasis, tissue coagulation, and tissue sticking. Significantly higher body weight gain ( P<.05) was noted at day 7 for monopolar and CO2 laser groups. Greatest tensile strength was seen in the steel scalpel and ultrasonic scalpel groups at the end of 28 days. Tissue re-epithelialization was fastest for the steel scalpel and ultrasonic scalpel groups (complete by day 7). Complete re-epithelialization of wounds of all treatment groups occurred by day 28. All groups had acute inflammation. Complete resolution of inflammation by day 14 took place in the steel scalpel and ultrasonic scalpel groups only. CONCLUSION: Use of the ultrasonic scalpel produced faster re-epithelialization and greater tensile strength than laser or electrosurgical instruments, with results comparable to those seen with the steel scalpel.

Animals↗

Comparison of the cutting efficiency of two ultrasonic units utilizing two different tips at two different power settings.

The objective of this in vitro study was to set up a testing protocol and utilize it to evaluate and compare the cutting efficiency of ultrasonic units. Evaluation of two ultrasonic units utilizing two different tips was done by measuring the weght of a dentin specimen before and after ultrasonic treatment for set time periods. The difference in weight was the amount of dentin removed. The ultrasonic units tested were the P5 Booster (Staelec, France) and the Spartan (Obtura-Spartan, Fenton, MO) machines. The tips tested were the CPR-2D and ETD20 types. The units were tested at maximum and medium power. All the experimental variables, ultrasonic unit type, power setting and tip type were found to have an effect on the cutting efficiency (P<0.0001). The P5 ultrasonic unit was more effective at dentin removal than the Spantan ultrasonic unit at both power settings. The ETD-20 tip was more effective at dentin removal than the CPR-2D tip on both units at both power settings.

Dentin↗

Medialization thyroplasty window creation using an ultrasonic surgical aspirator.

OBJECTIVES/HYPOTHESIS: The aim of the study was to investigate the use of an ultrasonic surgical aspirator for creation of the laryngeal cartilage window during medialization thyroplasty. STUDY DESIGN: Basic science. METHODS: Forty thyroplasty windows were constructed in fresh, unpreserved cadaver larynges. A 6 x 13-mm rectangular window and a 4 x 4-mm round window were created on each side of the larynges in a symmetrical fashion. A standard surgical drill with a 3-mm cutting burr was used on one side; the ultrasonic surgical aspirator was used on the contralateral side. The time required for window construction was recorded, as was the status of the inner perichondrium at window completion. RESULTS: For creation of the 6 x 13-mm window, a mean time of 128 seconds was required using a standard surgical drill. The mean time using the ultrasonic aspirator device was 91 seconds for the window of the same size (P < .008). For the 4-mm round window, drilling completed the task in a mean time of 63 seconds, compared with 40 seconds (P < .016) for the ultrasonic aspirator. On creation of the 6 x 13-mm window, there were 4 of 10 perichondrial violations in the drilled specimens, and there were no violations in creation of the window of the same size with the ultrasonic aspirator (P = .12). The 4-mm round window had no perichondrium violations in the standard drill group and only 1 of 10 violations in the ultrasonic aspirator group (P = .99). CONCLUSION: The study suggested that the ultrasonic surgical aspirator device may be an effective, efficient alternative to the standard drill for medialization thyroplasty window creation. Prospective clinical trials are warranted to better characterize its applicability.

Female↗

Ultrasonic data compression via parameter estimation.

Ultrasonic imaging in medical and industrial applications often requires a large amount of data collection. Consequently, it is desirable to use data compression techniques to reduce data and to facilitate the analysis and remote access of ultrasonic information. The precise data representation is paramount to the accurate analysis of the shape, size, and orientation of ultrasonic reflectors, as well as to the determination of the properties of the propagation path. In this study, a successive parameter estimation algorithm based on a modified version of the continuous wavelet transform (CWT) to compress and denoise ultrasonic signals is presented. It has been shown analytically that the CWT (i.e., time x frequency representation) yields an exact solution for the time-of-arrival and a biased solution for the center frequency. Consequently, a modified CWT (MCWT) based on the Gabor-Helstrom transform is introduced as a means to exactly estimate both time-of-arrival and center frequency of ultrasonic echoes. Furthermore, the MCWT also has been used to generate a phase x bandwidth representation of the ultrasonic echo. This representation allows the exact estimation of the phase and the bandwidth. The performance of this algorithm for data compression and signal analysis is studied using simulated and experimental ultrasonic signals. The successive parameter estimation algorithm achieves a data compression ratio of (1-5N/J), where J is the number of samples and N is the number of echoes in the signal. For a signal with 10 echoes and 2048 samples, a compression ratio of 96% is achieved with a signal-to-noise ratio (SNR) improvement above 20 dB. Furthermore, this algorithm performs robustly, yields accurate echo estimation, and results in SNR enhancements ranging from 10 to 60 dB for composite signals having SNR as low as -10 dB.

Algorithms↗

SEM analysis of the integrity of resected root apices of cadaver and extracted teeth after ultrasonic root-end preparation at different intensities.

AIM: To compare the integrity of root apices of cadaver and extracted teeth after resection, ultrasonic root-end cavity preparation at medium and low ultrasonic power settings and retrieval. METHODOLOGY: Root canal treatment, perpendicular root-end resection and root-end preparation were performed on single-rooted anterior and premolar teeth (49 teeth in situ in maxillary and mandibular jaws from cadavers and 45 extracted teeth). Apical root-end cavities were prepared with the S12/90 degrees D tip and the Suni-Max ultrasonic unit (Satelec, Merignac, France) at the intensity prescribed by the manufacturer (power 7 at power mode S) (34 cadaver teeth, 30 extracted teeth) and at a lower intensity (power 4 at power mode S) (15 cadaver teeth, 15 extracted teeth). After ultrasonic preparation the cadaver teeth were retrieved from the jaws. Exaflex impressions (GC Corporation, Tokyo, Japan) were made of the root apices after resection, root-end preparation and retrieval. These impressions were processed for SEM analysis, and the recordings evaluated for cracks and marginal chipping. RESULTS: In general, extracted teeth showed significantly more cracks and chipping than cadaver teeth. Lowering the ultrasonic power from medium to low intensity resulted in equal scores for cracks on extracted teeth and for chipping on cadaver teeth, in higher scores for cracks on cadavers and in lower scores for chipping on extracted teeth. Complete cracks and cracks originating from the root surface occurred only in extracted teeth. CONCLUSIONS: The number of cracks and degree of chipping caused by ultrasonic root-end preparation was higher on extracted teeth than on cadaver teeth. Lowering the ultrasonic power from medium to low intensity cannot be recommended as it resulted in more cracks and equal chipping on cadaver teeth. Investigation of techniques and materials should be conducted in situ and not on extracted teeth.

Apicoectomy↗

Significant influence of scaler tip design on root substance loss resulting from ultrasonic scaling: a laserprofilometric in vitro study.

OBJECTIVES: Ultrasonic scalers have become increasingly popular for subgingival debridement. The aim of the present study was to investigate the influence of different working tip designs (narrow versus wide) on root substance loss caused by either magnetostrictive or piezoelectric ultrasonic devices. METHODS: In this in vitro study, a magnetostrictive ultrasonic system with either Slimline or TFI-10 inserts and a piezoelectric ultrasonic system with either Perioprobe or Type-A inserts were compared at different application forces. Loss of root dentin was determined by defect width, defect depth and defect volume resulting from standardized instrumentation using laser profilometry. RESULTS: There were consistent and statistically significant differences between all groups. The mean observed dentin alterations for the magnetostrictive ultrasonic device operating a Slimline insert at a lateral force of 0.3 N were 254.4 microm, 6.3 microm and 22.5 microm3 and for the TFI-10 tip 759.0 microm, 23.5 microm and 160.2 microm3 for the parameters defect width, depth and volume, respectively. For the piezoelectric ultrasonic system operating a Perioprobe insert, the corresponding mean values were 352.0 microm/12.1 microm/56.4 microm3 and for the universal Type-A insert they were 402.4 microm/14.0 microm/133.4 microm3. With application forces of 0.7 N, root substance removal increased up to twofold. CONCLUSION: The present investigation could demonstrate that the aggressiveness of magnetostrictive and piezoelectric ultrasonic devices to root substance was significantly influenced by the scaler tip designs, increasing for wider scaler tips as compared with narrow, probe-shaped inserts.

Dental Instruments↗

Ultrasonication as a method to study enamel demineralisation during acid erosion.

The aim of this study was to use ultrasonication as a method to measure subsurface demineralisation of enamel. Polished human enamel samples with surface profiles within +/-0.3 microm were divided into 6 groups of 10 specimens. The groups of specimens were exposed to 0. 3% citric acid (pH 3.2) for 30 min, 1, 2, 3 or 4 h. The depths of the resulting lesions were measured using a profilometer. A control group was stored in water for 4 h. Ultrasonication in water was performed on the specimen groups for 5, 30, 120, 240 and 480 s with profilometric measurements at each time point. The depth of the erosion increased linearly with the exposure time. Most of the additional loss of enamel occurred with the 5-second ultrasonication. The 30-min and 1-hour erosion lesions were further deepened by approximately 1 microm with 5 s of ultrasonication. The 2-, 3- and 4-hour lesions were deepened by 2-4 microm with 5 s of ultrasonication. There were no changes in the control group. It is concluded that ultrasonication removed softened enamel from the surface of the eroded enamel. Ultrasonication together with accurate measurement of lesion depth by profilometry offers a useful method for studying the depth of enamel softening associated with erosion.

Analysis of Variance↗

Differences between blood flow as indicated by the hemodialysis blood roller pump and blood flow measured by an ultrasonic sensor.

BACKGROUND/AIM: The ultrasonic transit time is currently the best method for measuring the blood flow rate in the extracorporeal hemodialysis circuit. The purpose of this study was to analyze the differences between blood flow as indicated by the hemodialysis blood roller pump (prescribed blood flow) and by an ultrasonic flowmeter (delivered blood flow). METHODS: The ultrasonic blood flow was measured in 20 patients on chronic hemodialysis who were dialyzed through an arteriovenous fistula. During each dialysis session the ultrasonic blood flow was measured at three different blood roller pump flow rates (300, 350, and 400 ml/min). In order to analyze the influence of inflow and outflow pressures on blood flow, this study was conducted during nine consecutive dialysis sessions during which needles of different sizes were used. RESULTS: The ultrasonic flow was always lower than indicated by the blood roller pump: 265+/-12, 304+/-15, and 341+/- 19 ml/min for blood roller pump flow rates of 300, 350, and 400 ml/min, respectively (variability: -11.6, -13.1, and -14.8%, respectively). An univariate regression analysis showed that the reduction in flow recorded ultrasonically correlated with both venous blood line pressure (r = -0.2679, p<0.001) and negative arterial blood line pressure (r = 0. 6773, p<0.001). By multivariate analysis, only the arterial blood line pressure has a predictive value. When all measurements were grouped by arterial blood line pressure ranges, the variability between ultrasonic blood flow and blood roller pump flow was found to be similar in those groups with the same arterial blood line pressure, regardless of the blood roller pump flow rate. CONCLUSIONS: The blood flow indicated by the dialysis blood roller pump is always greater than the delivered blood flow, and this difference is in turn conditioned by the negative pressure induced by the blood roller pump in the arterial blood line.

Blood Flow Velocity↗

Susceptibility of acid-softened enamel to mechanical wear--ultrasonication versus toothbrushing abrasion.

The study aimed to compare the amounts of softened enamel removable by ultrasonication and by toothbrushing abrasion of briefly eroded samples. Thirty bovine enamel samples were demineralized in hydrochloric acid (pH 2.1) for 60 s and were then either brushed with 350 brushing strokes in toothpaste slurry (group A) or distilled water (group B) or were ultrasonicated for 120 s (group C). Enamel loss was measured after 10, 20, 50 and then after every 50 brushing strokes or after 5, 30, 60 and 120 s ultrasonication. Samples were indented with a Knoop diamond after erosion, and enamel loss due to abrasion or wear was calculated from the change in indentation depth after mechanical treatment. Within- and between-group comparisons were performed by ANOVA or t test. Initially, enamel loss increased with increasing brushing treatment or ultrasonication time. Enamel loss did not increase after 300 brushing strokes in group A (534 +/- 169 nm) or 250 brushing strokes in group B (423 +/- 80 nm), or after 60 s ultrasonication (231 +/- 72 nm). Enamel loss was significantly higher in groups A and B than in group C. The results confirm that ultrasonication removes only the outer, more highly demineralized part of the softened enamel layer. Results also indicate that toothbrushing abrasion removes more softened enamel from briefly eroded enamel than ultrasonication, and therefore probably removes partly demineralized enamel from the deeper part of the softened layer. In vivo, excessive toothbrushing might remove the softened enamel layer almost completely.

Animals↗

Aerosol and splatter production by focused spray and standard ultrasonic inserts.

BACKGROUND: Control of contamination in the dental office has sometimes deterred practitioners from using ultrasonic scalers. Recent studies point to the aerosol and splatter produced during ultrasonic scaling as a vehicle for the possible transmission of bloodborne pathogens. A recently introduced ultrasonic insert that focuses the spray produced during scaling may reduce this aerosol contamination. An aerosol reduction device (ARD) that is attached to the ultrasonic handpiece has been shown to reduce the contamination cloud by placing suction in close proximity to the ultrasonic tip. The purpose of this study was to compare the contamination produced by a standard insert (S) and the new focused spray (F) insert with and without the use of the aerosol reduction device (ARD). METHODS: The testing was conducted in vitro within a plastic enclosure using a dye in the coolant spray. After mock scaling of a dentoform model, the number of contaminated squares on the enclosure was counted and recorded. RESULTS: Analysis of the data indicated no significant difference (P >0.05, Mann-Whitney U test) between the S or F inserts in the amount of contamination produced. When the aerosol reduction device was used, there was a significant reduction (P <0.05, Mann-Whitney U test) in the amount of contamination for both inserts with a greater reduction for the standard insert. CONCLUSIONS: The traditional style of ultrasonic insert (S) and the newer focused coolant water insert (F) produce an equal amount of aerosol contamination. The amount of aerosol contamination produced by both inserts is copious. The ARD significantly reduced contamination with both styles of inserts. These findings support the use of a large bore high-volume evacuator whenever an ultrasonic scaler is used.

Aerosols↗