Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Suction”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13Linked to original sources

Prospective randomized clinical trial on suction elastic band ligator versus forceps ligator in the treatment of haemorrhoids.

OBJECTIVE: This prospective randomized clinical trial was undertaken to compare the use of a single-operator vacuum suction ligator and the traditional forceps ligator in terms of pain perception following the procedure, intra-procedure bleeding and other complications. METHODS: One hundred consecutive patients with second- and third-degree haemorrhoids presenting between July 2002 and September 2003 were randomized into suction and forceps groups for rubber band ligations. They were equally distributed in both groups, with a mean age of 48.7 years (range, 15-83 years). The immediate, 24-hour, 7-day and 14-day pain scores after the procedure were evaluated using a visual analogue scale. Intra-procedure bleeding and other complications at follow-up were evaluated. RESULTS: Pain perception was worse in the forceps group immediately after ligation, with a mean score of 6.08 compared with 3.08 in the suction group (p < 0.001). Pain score remained high among the forceps patients at 24 hours post-banding, with a mean score of 4.00 compared with 1.92 in the suction group (p < 0.001). There was no significant difference in terms of immediate and 24-hour pain perceptions whether two or three haemorrhoids were banded per session (p = 0.904 and p = 0.058). The amount of analgesia consumed after banding correlated well with the severity of pain reported, being higher among the forceps group with a mean of 4.48 tablets (p = 0.003). Intra-procedure bleeding occurred in 25 patients in the forceps group compared with five in the suction group (p < 0.001). There were no severe complications such as perianal sepsis, urinary retention, sphincter dysfunction or bleeding during the trial. CONCLUSION: Suction band ligation is superior to forceps ligation for the treatment of second- and third-degree haemorrhoids in terms of pain tolerance, amount of analgesia consumed and intra-procedure bleeding.

Adolescent↗

A clinical audit on the effect of suction drainage on microvascular anastomosis.

INTRODUCTION: There are reports that thrombosis in microsurgically anastomosed vessels occurred after the vessels were drawn into the suction drains. AIM: To study the effects of suction drainage on microvascular anastomosis. PATIENTS AND METHODS: The authors compared the proportion of complications in 77 patients who had suction drainage (n=45) or no suction drainage (n=32) with microvascular free flap surgery in the head and neck region. Ultrasonography and Doppler flow ultrasonography were performed on five more patients 3 days after the operation. RESULTS: There were no significant differences between the two retrospectively evaluated groups for incidence of postoperative complications. Ultrasound in the prospective study group revealed that vessels were neither sucked into the suction drain nor displaced towards the drain. CONCLUSION: These findings contravened the reports of vessels being sucked into drains and therefore the clinical use of suction drainage in conjunction with microsurgery in the head and neck region is still advocated.

Anastomosis, Surgical↗

[The influence of the drain suction in knee arthroplasty].

PROBLEM: In a prospective randomised clinical study, we investigated the impact of drain-suction on the post-operative blood loss and on both clinical and laboratory parameters after knee replacement operations. PATIENTS AND METHOD: In this study, 116 patients with unilateral implantation of knee replacements were evaluated. The patients' average age was 71.2 years. The operation was carried out mostly without tourniquet application. All patients received two wound drains, 57 with and 59 without suction. The postoperative blood loss as well as clinical and laboratory parameters were assessed. RESULTS: The average peri-operative blood loss amounted to 338 ml. The post-operative blood loss in the group without drain suction was 436 ml and 528 ml in the group with suction. No significant differences could be found concerning the hemoglobin values pre-operatively and on the first and seventh post-operative day, the drainage quantity 12, 24, 36, and 48 hours post-operatively, the wound healing and the CRP. Six patients in the group without and five patients in the group with drain-suction had to receive blood transfusions. DISCUSSION: The application of suction on the drainage system had no significant impact on the post-operative blood loss and the postoperative course. In nine out of ten cases no homologous blood was needed.

Adult↗

High-pressure gradients generated by closed-suction surgical drainage systems.

BACKGROUND: Closed suction drains remain in widespread use in surgical practice. There have been reports of complications associated with their use. We sought to characterize the pressure-generating capacities of three commonly used closed suction drainage systems. MATERIALS AND METHODS: Three commonly used closed suction surgical drainage systems were studied: Davol Reliavac 400 Evacuator, Jackson-Pratt Closed Wound Suction Drainage System, and Snyder Hemovac 400. Each drainage system was connected to a pneumatic pressure transducer, and pressure measurements were made. Measurements were made with the drain reservoirs at varying degrees of fullness. Measurements were also made while "stripping" the drains. RESULTS: In all three systems, maximal negative pressures (-71 to -175 mm Hg) were generated with the reservoirs empty of fluid. Pressure generation by all drains decreased as the volume of fluid in the reservoir increased. In all cases, drain "stripping" was associated with a transient elevation in drain pressure (p<0.05). In two out of three drains, stripping led to a significant residual increase in static drain pressure. CONCLUSION: Closed suction drains are capable of generating high pressures that may contribute to some complications associated with their use. Closed suction drainage systems differ with regard to their generation of negative pressure.

Drainage↗

Prevention of hypoxia and hyperoxia during endotracheal suctioning.

A new suction catheter, designed to deliver alternately oxygen or suction, prevented episodes of hypoxia and hyperoxia in a group of infants during endotracheal suctioning. Twenty infants received both conventional endotracheal suctioning and suctioning by the new catheter. The infants had a maximal change from a presuctioning transcutaneous oxygen (PtcO2) of 12 +/- 8 torr and required 3.1 +/- 2 min to regain their presuctioning oxygenation level compared to a maximal change of 21 +/- 10 torr (p less than .05) and a stabilization time of 5.3 +/- 2.6 min (p less than .05) in the conventionally treated group. Three study infants experienced an abnormal PtcO2 (either less than 40 or greater than 90 torr), while 13 control infants suffered these abnormalities (p less than .01). The use of this new suction device effectively reduced the exposure of this group of infants to episodes of aberrant oxygen states and allowed for a shorter recovery time.

Blood Gas Monitoring, Transcutaneous↗

Integration of a variable action suction adapter into ultrasonic aspirators.

PURPOSE: Use of ultrasonic aspirators has become a mainstay in the neurosurgical armamentarium. The handpiece design and ultrasonic parameters have evolved to maximize its safe and efficacious use. Despite these modifications, continuous suction through the tip of the aspirator can result in neurovascular damage, especially when the aspirator is working in the cavernous sinus region or cerebellopontine angle. CONCEPT: We describe the integration of a variable suction adapter into the existing handpiece of an ultrasonic aspirator to minimize potential injury from the continuous forceful suction normally associated with the use of these devices. RATIONALE: The integration of such an adapter can reduce the potential for suction injury to cranial nerves or microvascular structures or smaller-caliber arteries and veins. DISCUSSION: This variable action suction adapter can decrease suction injuries to cranial nerves or the microvasculature.

Brain Neoplasms↗

Endotracheal suctioning causes right upper lobe collapse in intubated children.

OBJECTIVE: Right upper lobe collapse is a common radiographic finding in intubated children. We hypothesized that deep suctioning and uncontrolled negative pressures during endotracheal tube suctioning were significant contributory factors. METHODS: The incidence of right upper lobe (RUL) collapse in intubated, ventilated children on a paediatric cardiac intensive care unit was determined over a 3-month period (n = 102). Graduated suction catheters and suction vacuums of < 165 cm H2O were then introduced. Another prospective audit was carried out 3 months later (n = 60). RESULTS: We found that 24% developed RUL collapse and 4 developed an apical pneumothorax. Following the introduction of graduated catheters and controlled vacuums pressures; a significant reduction in the incidence of RUL collapse, to 7%, was observed (p < 0.05). CONCLUSIONS: We conclude that high negative pressure and deep-suctioning causes RUL collapse in children. Any lobar collapse not only prolongs the child's stay in intensive care, but can be associated with further morbidity which may have a serious implication. By improving suctioning technique this morbidity can be significantly reduced.

Child↗

Counteraction of aortic baroreflex to carotid sinus baroreflex in a neck suction model.

Although neck suction has been widely used in the evaluation of carotid sinus baroreflex function in humans, counteraction of the aortic baroreflex tends to complicate any interpretation of observed arterial pressure (AP) response. To determine whether a simple linear model can account for the AP response during neck suction, we developed an animal model of the neck suction procedure in which changes in carotid distension pressure during neck suction were directly imposed on the isolated carotid sinus. In six anesthetized rabbits, a 50-mmHg pressure perturbation on the carotid sinus decreased AP by -27.4+/-4.8 mmHg when the aortic baroreflex was disabled. Enabling the aortic baroreflex significantly attenuated the AP response (-21.5+/-3.8 mmHg, P<0.01). The observed closed-loop gain during simulated neck suction was well predicted by the open-loop gains of the carotid sinus and aortic baroreflexes using the linear model (-0.43+/-0.13 predicted vs. -0.41 +/-0.10 measured). We conclude that the linear model can be used as the first approximation to interpret AP response during neck suction.

Animals↗

No trade-off between biting and suction feeding performance in clariid catfishes.

It is generally assumed that biting performance trades off with suction performance in fish because both feeding types may place conflicting demands on the cranial musculo-skeletal system. However, the functional consequences of morphological adaptations enhancing biting on the mechanics and performance of suction feeding in fish remain obscure. In this study, suction feeding performance was compared between three clariid catfish species differing considerably in their biting capacity, by measuring the velocity of a standardized prey being sucked into the buccal cavity using high-speed cineradiography. In addition, buccal volume changes during prey capture were quantified by ellipse modelling. As all species were able to accelerate the prey to similar peak velocities, our results demonstrate the possibility for catfishes to increase bite performance considerably without compromising suction performance. The amount of buccal expansion in the ventral direction is approximately equal for all species. Consequently, the system generating expansion through ventral rotation of the lower jaw, hyoid and pectoral girdle is apparently not constrained (mechanically or architectonically) by the hypertrophy of the jaw adductors. As the effect of a reduced magnitude of lateral expansion (suspensorium abduction) on suction performance in Clariidae appears to be negligible (for example in Gymnallabes typus), these data demonstrate the dominant role of ventral expansion for producing suction in these fish.

Animals↗

[Evaluation of oxygenation, ventilation and respiratory mechanics before and after endotracheal suction in mechanically ventilated children].

OBJECTIVES: The aim of this study was to know the effects of endotracheal suction in respiratory mechanics and oxigenation of patients with mechanical ventilation. METHODS: 13 children were studied in the pediatric intensive care unit of Hospital São Paulo, age between 47 days and 5 years old, male and female, surgical and clinic pathology, intubated by cuffed endotracheal tube, sedated and paralyzed few minutes before measurements, under previous established suction routine without preventive maneuvers, followed by a continuous monitoring of oxygenation, ventilation and respiratory mechanics under identical ventilatory sets. The parameters analyzed was Heart rate; SpO2; ph arterial; PaO2; PaCO2; SaO2; inspiratory and expiratory tidal volume; minute volume; dynamic compliance, respiratory resistance; mean airway pressure; PEEP and PEEPi., and the measurements were made immediately before suction, immediately after, ten and twenty minutes after suction RESULTS: The results showed that the technique increase the CO2 arterial pressures (PaCO2) even after 20 minutes; decrease the oxygen saturation (SpO2) immediately after the procedure with regular recuperation after 10 minutes and decrease the lung compliance (Cdin.) immediately after with lower recuperation after 10 minutes. CONCLUSION: We concluded that intratracheal suction in front of compromise of oxygenation, ventilation or respiratory mechanic, applied as minimal as possible under preventive maneuvers. We need more studies to establish the real need of intratracheal suction and a practice guideline of intervention to avoid deleterious effects of that in pediatric patients.

Child, Preschool↗

Retrograde suction decompression of giant paraclinoid aneurysms using a No. 7 French balloon-containing guide catheter. Technical note.

The treatment of large and giant paraclinoid carotid artery (CA) aneurysms often requires the use of suction decompression for safe and effective occlusion. Both open and endovascular suction decompression techniques have been described previously. In this article the authors describe a revised endovascular suction decompression technique that provides several advantages in the treatment of large and giant paraclinoid and CA aneurysms. A 51-year-old woman presented with a relatively brief history of progressive visual loss in the right eye, nonspecific headache, and an afferent pupillary defect. After angiography studies had been obtained, it was determined that she had a giant right paraclinoid internal CA aneurysm with a dome size of approximately 26 mm on the right and a neck diameter of 10 mm. A modified technique was performed in which suction decompression was used. With the aid of a No. 7 French Concentric balloon guide catheter (Concentric Medical, Inc., Mountain View, CA) and application of a temporary clip distal to the aneurysm, the aneurysm was trapped and decompressed using retrograde suction through the guide catheter when the balloon was inflated. After satisfactory placement of three permanent clips, an intraoperative angiogram obtained through the same guide catheter confirmed CA patency. The aneurysm was then punctured and aspirated, ensuring complete occlusion of the aneurysm sac and reconstruction of the parent vessel. The patient made an excellent recovery and did not suffer any complications. She did not experience worsening in her vision. This technical modification to endovascular suction decompression allows several potential advantages, including higher volume decompression and the ability to deliver endovascular devices to distal arterial locations.

Carotid Artery Diseases↗

Instillation of normal saline before suctioning in patients with pneumonia.

This study was conducted to investigate the effects of a no saline, a 2 ml and a 5 ml saline instillation prior to endotracheal suctioning on oxygen saturation in patients with pneumonia. The subjects in this study were 16 pneumonic patients with a tracheotomy tube, who had been admitted to the neuro-surgical intensive care unit at a university hospital in Seoul Korea. All three (0, 2 and 5 ml) saline instillation methods were applied to the 16 patients. The methods were randomly assigned to each patient. Each of the instillation methods was applied in a four-step sequence: 1) recording the level of oxygen saturation (baseline levels), 2) instilling normal saline, 3) supplying oxygen and suctioning, and 4) recording the level of oxygen saturation. The oxygen saturation was evaluated using pulse oximetry. The recovery times for oxygen saturation to return to baseline levels following suctioning were, just after suctioning, 45 seconds after suctioning and in excess of 5 minutes with 0, 2 and 5 ml saline instillations, respectively. Instillation of normal saline before suctioning could have an adverse effect on oxygen saturation, and should be used carefully as a routine intervention in patients who have pneumonia.

Adult↗

Dissemination of respiratory secretions during tracheal tube suctioning in an intensive care unit.

Most intensive care patients require frequent tracheal toilet, a procedure usually performed by suctioning the tracheal tube. Such procedures often result in the production and dissemination of droplets. We measured the distance visible droplets disseminated during tracheal tube suctioning of patients in an adult surgical intensive care unit. Fifty consecutive suction procedures in 14 patients intubated with a cuffed tracheal tube were investigated. Visible droplets were scattered over a mean distance of 60 +/- 39 cm (range 25 to 168 cm) from the tracheal tube. Blood agar culture plates were placed at three fixed points from the tracheal tube to identify organisms resulting from environmental contamination (control plates). This was repeated during suctioning procedures (study plates) to look into the occurrence of bacteriological cultures that differ from the control plates. Nine of the 14 patients had tracheal tube aspirate cultures done as part of their work-up for sepsis. In more than 30% of the suctioning procedures on these 9 patients, study plates grew bacteria that were similar to those present in their tracheal tube aspirates. In view of these observations, greater care should be taken to avoid contamination of the patient's immediate environment during tracheal tube suctioning and in the design of the intensive care unit.

Acinetobacter↗

[Quality of washed autologous erythrocytes from drainage-suction pumps].

High sub-pressure in high-vacuum suction bottles falls as the bottles fill up. Suction pumps with reservoir have a constant low suction level and decisive advantages. The question is: does the use of a suction pump before processing and retransfusion influence the quality of the erythrocytes? The randomized, controlled, prospective study presented here deals with drainage blood and washed autologous red blood cells (warbc) from 60 patients after hip endoprosthesis surgery. In a comparison between suction pump and redon bottle, the following parameters were studied: haematological-parameter (haemoglobin, haematocrit, erythrocyte count, leukocyte count, thrombocyte count, MCV, MCH, MCHC), vitality (osmotic fragility, 2,3-DPG) and haemolysis parameter (GOT, LDH, plasma haemoglobin, potassium). Control samples were taken immediately after operation: sample one from drainage blood before processing and sample two from warbc before retransfusion. There were no significant statistical differences between the groups. The osmotic fragility of the retransfused red blood cells was slightly above normal values, while the 2,3-DPG was normal. "Old" erythrocytes were haemolysed. The concentration of plasma haemoglobin was clearly above the normal range. In the "redon group" GOT and LDH were clearly increased. The quality of erythrocytes from suction pump reservoirs is not decisively impaired.

Blood Specimen Collection↗

DeLee suction. Does it have clinical significance?

OBJECTIVE: To evaluate the null hypothesis that there would be no difference in neonatal outcome in infants who underwent DeLee suction vs. those who underwent bulb suction when thick meconium was present. This difference was defined as a one-day difference in length of stay, two-point difference in the five-minute Apgar score or significant difference in blood gases. STUDY DESIGN: A power calculation based on a one-day length of stay found that 115 patients would be needed in each arm. A cohort of 115 consecutive deliveries with the presence of thick meconium was reviewed during each time period when DeLee suction was utilized and then matched with deliveries that used bulb suction. RESULTS: Two hundred thirty charts were reviewed. Length of stay, one-minute Apgar score, five-minute Apgar score, blood gases, gestational age and incidence of amnioinfusion were compared. There was no significant difference in any variable. Meconium aspiration syndrome in the period studied remained stable at < 1%. CONCLUSION: There was no significant clinical change in neonatal outcome with the abandonment of nasopharyngeal DeLee suction on the perineum when meconium was present. We recommend the use of bulb suction as routine obstetric practice even in the presence of thick meconium.

Apgar Score↗

The effect of controlled aprotinin administration through cardiotomy suction during cardiopulmonary bypass.

Cardiotomy suction enhances inflammation and fibrinolysis during cardiopulmonary bypass (CPB). Aprotinin has been shown to reduce the generalized inflammatory insults associated with CPB. The purpose of this study was to evaluate the effect of Aprotinin administration through cardiotomy suction on the inflammatory and fibrinolytic responses during CPB. A pig model of CPB was utilized including 8 animals divided into control and treatment groups. In the treatment group, Aprotinin was infused into the cardiotomy suction (3000 KIU/min), while the same volume of saline was infused in the control group. D-dimer, platelet count, and IL-8 level were analyzed from systemic and cardiotomy suction. It was found that Aprotinin significantly suppressed the increase in D-dimer levels in the systemic (476.3 +/- 341.2 vs. 1218.8 +/- 281.3 ng/ml, p < 0.05) and the cardiotomy suction (565.0 +/- 192.5 vs. 1875.0 +/- 125.0 ng/ml, p < 0.05). Platelet count fell in both groups during CPB, although the reduction was greater in the control (13.1 +/- 5.1 vs. 37.9 +/- 13.8%, p < 0.05). In addition, IL-8 level in the suction solution was significantly lower in the Aprotinin group (56.5 +/- 18.0 vs. 136.3 +/- 14.8 pg/ml, p < 0.05). In conclusion, this study suggested that Aprotinin treatment of the cardiotomy solution might be an effective way of reducing fibrinolysis, platelet reduction, and inflammation associated with CPB.

Animals↗

Cardiac positioning using an apical suction device maintains beating heart hemodynamics.

BACKGROUND: Cardiac positioning during off-pump coronary artery bypass (OPCAB) using deep pericardial sutures (DPS) typically results in some degree of hemodynamic compromise. We sought to determine whether cardiac positioning using an apical suction device was hemodynamically superior to DPS. METHODS: Five healthy pigs underwent sternotomy and instrumentation to measure right atrial (RA) pressure, left ventricular (LV) pressure and volume, and aortic pressure and flow. These variables were recorded at baseline, with simple attachment of the apical suction device (Xpose Access Device, Guidant, Inc.), and during exposure of the posterior descending artery (PDA) and obtuse marginal (OM) branches of the left circumflex artery using DPS and the apical suction device. RESULTS: Application of the apical suction device to the beating heart in neutral anatomic position did not result in any statistically significant change in hemodynamics compared to baseline except for a small decrease in RA pressure. DPS positioning resulted in statistically significant compromise in nearly all measured hemodynamic parameters, including cardiac output (-21% PDA, -30% OM), mean arterial pressure (-18% PDA, -26% OM), and stroke work (-31% PDA, -38% OM). In addition, LV end-diastolic pressure decreased (-59% PDA, -51% OM) while RA pressure increased (+17% PDA, +16% OM). Similar target exposure using the apical suction device resulted in near-baseline hemodynamics. The only statistically significant changes were a modest decrease in cardiac output (-18% OM) and RA pressure (-11% PDA). CONCLUSION: DPS positioning significantly compromises hemodynamics due to reduced LV filling. The apical suction device provides good exposure with less hemodynamic compromise.

Animals↗

Weekly versus daily changes of in-line suction catheters: impact on rates of ventilator-associated pneumonia and associated costs.

BACKGROUND: An earlier randomized, controlled trial showed that weekly or as-needed (as opposed to daily) changes of in-line suction catheters were associated with substantial cost savings, without a higher rate of ventilator-associated pneumonia (VAP). To examine the impact of decreasing the frequency of in-line suction catheter changes in our medical intensive care unit, we conducted an observational study, comparing the catheter costs and frequency of VAP during (1) a control period, during which in-line suction catheters were changed daily, and (2) a treatment period, during which the catheters were changed every 7 days or sooner if needed, for mechanical failure or soilage. METHODS: All adult patients admitted to our 18-bed medical intensive care unit were evaluated for the 3-month interval 1 year prior to the practice change (May through July 1998) and for the 3 months after implementing the new policy (May through July 1999). To avoid bias related to usual seasonal variation in VAP frequency, we also determined (via medical records) the VAP rate during May through July 1997. The occurrence of VAP was ascertained by an infection control practitioner, using criteria established by the Centers for Disease Control and applied in a standard fashion. The VAP rate was calculated as the mean number of VAPs per 100 ventilator-days for each 3-month interval. Use of ventilators, humidifiers, and non-heated-wire, disposable circuits was uniform during the study, as were policies regarding humidity, temperature settings, and frequency of routine ventilator circuit changes. RESULTS: During the control period 146 patients accounted for 1,075 ventilator-days and there were 2 VAPs (0.19 VAPs per 100 ventilator-days). During the treatment period 143 patients accounted for 1,167 ventilator-days and there were no VAPs. The mean +/- SD duration of in-line suction catheter use during the treatment period was 3.8 +/- 0.8 days, and 51% of the patients had the same catheter in place for > 3 days (range 4-9 days). The actual cost of catheters used during the treatment period was lower than during the control period ($1,330 vs $6,026), predicting annual catheter cost savings of $18,782. CONCLUSIONS: We conclude that (1) a policy of weekly (vs daily) change of in-line suction catheter is associated with substantial cost savings, with no significant increase in the frequency of VAP, and (2) to the extent that these findings confirm the results of prior studies they support a policy of changing in-line suction catheters weekly rather than daily.

Catheterization↗