Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “SET”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13Linked to original sources

Single- vs. multiple-set strength training in women.

The aim of this study was to compare the effects of single-set and multiple-set strength training in women. Twenty-seven women (aged 20-40 years) with basic experience in strength training were randomly allocated to either a single-set group (n = 9), a 3-set group (n = 9), or a nontraining control group (n = 9). Both training groups underwent a whole-body strengthening program, exercising 2 days a week for 6 weeks. Exercises included bilateral leg extension, bilateral leg curl, abdominal crunch, seated hip adduction/abduction, seated bench press, and lateral pull-down. The single-set group's program consisted of only 1 set of 6-9 repetitions until failure, whereas the multiple-set group trained with 3 sets of 6-9 repetitions until failure (rest interval between sets, 2 minutes). Two times before and 3 days after termination of the training program, subjects were tested for their 1 repetition maximum strength on the bilateral leg extension and the seated bench press machine. Data were analyzed using a repeated-measures analysis of variance, Scheffé tests, t-tests, and calculation of effect sizes. Both training groups made significant strength improvements in leg extension (multiple-set group, 15%; single-set group, 6%; p 0.05). However, in the seated bench press only the 3-set group showed a significant increase in maximal strength (10%). Calculation of effect sizes and percentage gains revealed higher strength gains in the multiple-set group. No significant differences were found in the control group. These findings suggest superior strength gains occurred following 3-set strength training compared with single-set strength training in women with basic experience in resistance training.

Adult↗

Comparison of four techniques for monitoring the setting kinetics of gypsum.

STATEMENT OF PROBLEM: Setting time of gypsum depends on the method of measurement. PURPOSE: In this study, four methods for ascertaining the setting time of gypsum were compared. MATERIAL AND METHODS: Gypsum setting was evaluated with Gillmore needles, setting expansion, scanning electron microscopy, and x-ray diffraction. Both die stone (Vel-Mix) and fast-setting dental stone (Snap-Stone) were investigated. By using Gillmore needles, both initial set and final set were recorded. Setting expansion was monitored until equilibrium was achieved. For scanning electron microscopy, samples of mixed stone were immersed into liquid nitrogen to stop the reaction. The water was subsequently removed by freeze-drying. Samples were then examined in a scanning electron microscope. For x-ray diffraction, the percentages of dihydrate and hemihydrate crystals were monitored every 1.5 minutes. RESULTS: Setting times for the fast-setting type III stone and for the regular-setting type IV stone were approximately 3 and 10 minutes, respectively, with the Gillmore needle indentation tests; 10 and 20 minutes with scanning electron microscopy; and 20 and 60 minutes with x-ray diffraction. CONCLUSION: Scanning electron microscopy, setting expansion, and x-ray diffraction indicated changes that occurred at times after a clinically relevant set was obtained in the gypsum setting reaction.

Calcium Sulfate↗

[Evaluation of CVC-set].

OBJECTIVE: Frequently central venous catheter sets do not contain all necessary materials. To evaluate, if combined measures using a specially arranged central venous catheter (CVC) set result in economical and clinical advantages, we compared both cost and time differences of a CVC complete set with ECG guide wire lead and an adhesive fixation with a standard set requiring additional materials, ECG fluid column lead and surgical suture. Furthermore, quality of different ECG leads, the reliability and tolerability of the adhesive fixation was compared. METHODS: 76 elective adult surgical patients were randomly assigned to receive either a control CVC set or a test CVC complete set, which was featured by preconnected stopcocks, included sterile drapes, guide wire ECG position control, and an adhesive fixation. We performed ECG-guided placement of the central venous catheter using a guide wire lead in the test CVC set vs. fluid column lead in the control CVC set. Time was recorded for preparation phase of the nurse and the anesthetist, for the puncture phase, for the ECG position control and time for CVC fixation. Quality of ECG position control using guide wire or fluid column was determined by forming Pmax/R ratio. Costs of the complete set and the standard set with additional material were compared. RESULTS: Times for preparation of nurse and anesthetists, for ECG position control and catheter fixation were significantly shorter using the test catheter set and resulted in a total time saving of 6 min (P < 0.01). Times for sterile preparation and central venous puncture were not significantly different between the groups. ECG position control using the guide wire was successful in 37 out of 38 patients (97%) and in 34 of 38 patients (89%), respectively. Pmax/R ratio was 0.8 +/- 0.2 using the guide wire versus 0.5 +/- 0.2, respectively. There were only 2 out of 38 adhesive fixations, that had to be replaced, while the mean duration of adhesive fixation was 6.2 days (3-15 days). Avoidance of disposable materials in the test CVC set led to a significant reduction of costs compared to the control CVC set. CONCLUSION: The test CVC complete set allows a significant time saving and cost reduction in performing a central venous catheter line because of completely included disposable materials. CVC position control via guide wire needs less time and shows significantly better quality of ECG compared to fluid column ECG lead. An adhesive revealed to be a reliable CVC fixation comparable to a surgical suture.

Adhesives↗

Efficacy of large-bore intravenous fluid administration sets designed for rapid volume resuscitation.

We tested the hypothesis that large-bore iv tubing sets provide greater in vitro flow rates than conventional sets currently utilized for the administration of normal saline. The study was conducted in two parts. First, flow rates were measured using a conventional iv tubing set under gravity and 300 mm Hg of pressure, and four large-bore iv tubing sets under gravity. Additional measurements were made after attaching various catheters and sheaths ranging in size from 14 ga to 9 Fr. Five trials were conducted for each combination. Second, we measured the amount of time taken in a mock drill by 28 randomly chosen anesthesiology residents and staff to load a unit of packed RBC into a pressure infusor bag, inflate to 300 mm Hg, and deflate to ambient pressure. Data were analyzed for individual tubing sets as a whole and individual catheter-tubing set combinations, using the Mann-Whitney U test with Bonferroni adjustment. Statistically significant (p less than .03) differences in flow rates were noted between the conventional set under gravity compared with both the pressurized conventional set and the large-bore tubing sets under gravity. There was no statistical difference in flow rates between pressurized conventional iv sets and large-bore iv sets. Mean time necessary for the 28 anesthesiology staff and residents to pressurize and deflate a conventional tubing set was 65 sec/bag of packed RBC. We conclude that a considerable amount of time can be saved by utilizing large-bore iv tubing sets instead of conventional pressurized sets during massive volume resuscitation. Clinical trials are indicated to corroborate these results.

Analysis of Variance↗

Methods for evaluating clustering algorithms for gene expression data using a reference set of functional classes.

BACKGROUND: A cluster analysis is the most commonly performed procedure (often regarded as a first step) on a set of gene expression profiles. In most cases, a post hoc analysis is done to see if the genes in the same clusters can be functionally correlated. While past successes of such analyses have often been reported in a number of microarray studies (most of which used the standard hierarchical clustering, UPGMA, with one minus the Pearson's correlation coefficient as a measure of dissimilarity), often times such groupings could be misleading. More importantly, a systematic evaluation of the entire set of clusters produced by such unsupervised procedures is necessary since they also contain genes that are seemingly unrelated or may have more than one common function. Here we quantify the performance of a given unsupervised clustering algorithm applied to a given microarray study in terms of its ability to produce biologically meaningful clusters using a reference set of functional classes. Such a reference set may come from prior biological knowledge specific to a microarray study or may be formed using the growing databases of gene ontologies (GO) for the annotated genes of the relevant species. RESULTS: In this paper, we introduce two performance measures for evaluating the results of a clustering algorithm in its ability to produce biologically meaningful clusters. The first measure is a biological homogeneity index (BHI). As the name suggests, it is a measure of how biologically homogeneous the clusters are. This can be used to quantify the performance of a given clustering algorithm such as UPGMA in grouping genes for a particular data set and also for comparing the performance of a number of competing clustering algorithms applied to the same data set. The second performance measure is called a biological stability index (BSI). For a given clustering algorithm and an expression data set, it measures the consistency of the clustering algorithm's ability to produce biologically meaningful clusters when applied repeatedly to similar data sets. A good clustering algorithm should have high BHI and moderate to high BSI. We evaluated the performance of ten well known clustering algorithms on two gene expression data sets and identified the optimal algorithm in each case. The first data set deals with SAGE profiles of differentially expressed tags between normal and ductal carcinoma in situ samples of breast cancer patients. The second data set contains the expression profiles over time of positively expressed genes (ORF's) during sporulation of budding yeast. Two separate choices of the functional classes were used for this data set and the results were compared for consistency. CONCLUSION: Functional information of annotated genes available from various GO databases mined using ontology tools can be used to systematically judge the results of an unsupervised clustering algorithm as applied to a gene expression data set in clustering genes. This information could be used to select the right algorithm from a class of clustering algorithms for the given data set.

Algorithms↗

How does correlation structure differ between real and fabricated data-sets?

BACKGROUND: Misconduct in medical research has been the subject of many papers in recent years. Among different types of misconduct, data fabrication might be considered as one of the most severe cases. There have been some arguments that correlation coefficients in fabricated data-sets are usually greater than that found in real data-sets. We aim to study the differences between real and fabricated data-sets in term of the association between two variables. METHOD: Three examples are presented where outcomes from made up (fabricated) data-sets are compared with the results from three real data-sets and with appropriate simulated data-sets. Data-sets were made up by faculty members in three universities. The first two examples are devoted to the correlation structures between continuous variables in two different settings: first, when there is high correlation coefficient between variables, second, when the variables are not correlated. In the third example the differences between real data-set and fabricated data-sets are studied using the independent t-test for comparison between two means. RESULTS: In general, higher correlation coefficients are seen in made up data-sets compared to the real data-sets. This occurs even when the participants are aware that the correlation coefficient for the corresponding real data-set is zero. The findings from the third example, a comparison between means in two groups, shows that many people tend to make up data with less or no differences between groups even when they know how and to what extent the groups are different. CONCLUSION: This study indicates that high correlation coefficients can be considered as a leading sign of data fabrication; as more than 40% of the participants generated variables with correlation coefficients greater than 0.70. However, when inspecting for the differences between means in different groups, the same rule may not be applicable as we observed smaller differences between groups in made up compared to the real data-set. We also showed that inspecting the scatter-plot of two variables can be considered as a useful tool for uncovering fabricated data.

Adult↗

Reduction of interlaboratory variability in flow cytometric immunophenotyping by standardization of instrument set-up and calibration, and standard list mode data analysis.

Two workshops addressed the question to which degree standardization of instrument set-up and calibration, and standard list mode data analysis would reduce interlaboratory variability of flow cytometric results on prestained peripheral blood mononuclear cells (PBMC). Standard instrument set-up included uniform positioning of the "windows of analysis" for the forward and sideward light scatter and fluorescence (FL) 1 (i.e., fluorescein isothiocyanate [FITC]) and 2 (i.e., phycoerythrin [PE]) parameters. Reference standards and PBMC, double-stained with FITC- and PE-conjugated monoclonal antibodies covering a wide range of FL intensities and coexpression patterns, were sent out to 25 laboratories in Workshop 1 and to 35 laboratories in Workshop 2 with the following requests: a) to set up instruments according to local and standard protocols, b) to acquire list mode data on the PBMC with both instrument settings, and c) to analyze both datasets according to local protocols. Standard analysis of the list mode data acquired with uniform instrument settings was performed centrally using so-called "latent class model" software (Van Putten et al., Cytometry 14:86-96, 1993). This software provides an automated, "no-gating" analytical method of lymphocyte immunophenotypes and employs fixed FL marker settings as defined prior to each analytical run. In Workshop 1, these markers were set in identical histogram channels for all instruments based on results obtained with a reference instrument. Standard analysis of list mode data acquired after uniform instrument set-up led only to a 13% reduction of interlaboratory variability of results as compared to data analysis using local protocols. The standard protocol for instrument set-up led to uniform positioning of relatively strong FL signals but variable positioning of unstained cells on the FL histogram scales. Hence, standard FL marker settings were inappropriate for some instruments. Therefore, instrument responses to FITC and PE signals in Workshop 2 were calibrated using microbeads labeled with FITC or PE in a range of predefined FL intensities expressed in MESF units (molecules of equivalent soluble fluorochrome). That approach allowed the positioning of the FL markers for the standard analysis on the basis of identical FL1 and FL2 intensities, expressed in MESF units, for all instruments. Standard analysis of list mode data acquired after uniform instrument set-up and calibrated FL marker settings led to a 43% reduction of interlaboratory variability as compared to data analysis to local protocols. We conclude that standard list mode data analysis using fixed FL marker settings reduces the interlaboratory variability of flow cytometric results on prestained PBMC, provided that the instruments have been set up in a uniform way and that FL markers have been standardized on the basis of calibration of each instrument's response to the corresponding FL signals.

Antigens, CD↗

[Spectral characteristics of EEG during formation a set to illusory length perception (Müller-Lyer illusion)].

A cognitive set to illusory perception of linear relationships was formed in 56 young healthy subjects. After 10 presentations of Müller-Lyer figures, 39 subjects formed the stable set. In 17 subjects the unstable set was formed. The spectral power of the EEG led from different cortical areas was studied at different stages of set formation. Analysis of variance showed that the factors "set stage" and "group" x "set stage" x "hemisphere" exert significant influence on the EEG spectral power in the delta range in the frontal area. In the subjects with stable set, the power of this spectral component increased at the stages of set formation and actualization and returned to its initial values during set extinction. The between-group difference was more expressed in the left hemisphere. In subjects, which formed the stable set, the power of the occipitotemporal alpha rhythm in the reference state was higher than in subjects with the unstable set. In the process of set formation, the dynamics of the alpha spectral component (8-10 Hz) was more expressed in the stable group: its power increased to a greater extent at the stages of set actualization and extinction. In both groups, there were no significant changes in the alpha2 power over the course of the experiment.

Adult↗

SPECT imaging with off-set detector system: comparison of sampling angles 2, 4 and 6 degrees.

PURPOSE: We evaluated an off set reconstruction method for single photon emission computed tomography (SPECT), and compared it with the conventional on set reconstruction method, using sampling angles of 2, 4, and 6 degrees. METHOD: A triple-detector system was used. In the off-set acquisition, sampling angles of the opposite detector were shifted 1/2 of the sampling angles of 2, 4, and 6 degrees. For example, when projection data were acquired every 6-degrees (sampling angle = 6 degrees), the projection angles were at 0 degrees, 6 degrees, 12 degrees, and 174 degrees with one detector, and 177 degrees, 183 degrees, 189 degrees, and 357 degrees with the other, opposite, detector. The conventional on set reconstruction images were compared with an off set reconstruction for a pool phantom of uniform concentration, a hot rods phantom, a myocardial phantom, and a human study. RESULTS: The off set reconstruction method was better at all three sampling angles. FWHM (mm) were 11.02 at off-set versus 11.17 at on-set (sampling angle 2 degrees), 11.13 at off-set versus 11.48 at on-set (sampling angle 4 degrees), and 11.24 at off-set versus 11.64 at on-set (sampling angle 6 degrees), respectively. In human myocardium SPECT, visualization of the interventricular septum and cardiac cavity was improved. CONCLUSION: Off set reconstruction by means of filtered back projection will be an efficient sampling mode, having a larger number of effective projection angles.

Adult↗

A comparison of articulator settings obtained by using an electronic pantograph and lateral interocclusal recordings.

Articulator settings were obtained for two subjects 10 times in a 2-week period by using both a lateral interocclusal record technique and a Pantronic pantograph. The ORB and PSS articulator settings obtained from the two techniques were compared and the following conclusions drawn. 1. Over a 2-week period, the variance in the Pantronic pantograph ORB and PSS articulator settings was less than the variance in the setting obtained by using lateral interocclusal records. For the Pantronic pantograph technique, 95% of any ORB settings were within 2.5 degrees of the Pantronic pantograph mean and 95% of any PSS settings were within 1.9 degrees of the Pantronic pantograph mean. For the interocclusal record technique, 95% of the ORB settings made with interocclusal records were within 11.9 degrees of the mean for one subject and 13.4 degrees of the mean interocclusal records setting for the other subject. For the PSS settings, 95% of the interocclusal record settings were within 10.1 degrees of the mean setting for one subject and 11.6 degrees of the mean interoccusal record setting for the other subject. 2. In adjusting the ORB and PSS articulator settings, the maximum potential occlusal errors that may be produced by using the Pantronic pantograph are smaller than the maximum errors that may be produced in using the lateral interocclusal record technique.

Dental Articulators↗

Temperature effects on the rheological properties of current polyether and polysiloxane impression materials during setting.

STATEMENT OF PROBLEM: Rheological tests of elastomeric impression materials during setting have been most often conducted at room temperature rather than at intraoral temperature. Because temperature may affect properties and the setting kinetics, clinically relevant inferences may not be accurate with studies conducted at room temperature. PURPOSE: The purpose of this study was to determine the viscoelastic properties of new low- and medium-viscosity elastomeric impression materials during setting at 33 degrees C and to evaluate the medium-viscosity materials at 3 additional temperatures. MATERIAL AND METHODS: The impression materials investigated at 33 degrees C were 2 polyvinylsiloxanes (PVS) (Aquasil Deca and Aquasil LV) and 5 polyethers (PE) (Impregum Penta, Impregum Penta Soft H, Impregum Penta Soft L, Impregum Garant Soft L, and Permadyne Garant L). Three impression materials (Aquasil Deca, Impregum Penta, and Impregum Penta Soft H) were also investigated at 25 degrees, 29 degrees, and 37 degrees C. Time-dependent oscillatory rheometry was carried out on these materials (n=3) with a rheometer with a 25-mm diameter parallel plate cell. The storage modulus (G') and the loss tangent (tandelta) were determined as functions of time over a period from 0 seconds to 900 seconds, commencing 40 seconds after mixing. Induction time (t(ind)) or initial setting time and tandelta, the relative liquidlike behavior, were also computed. A single-factor analysis of variance (ANOVA) was used for the properties determined at 33 degrees C and a 2-factor ANOVA was used for the temperature studies, with hypothesis testing at alpha=.05. RESULTS: The G'(t) curves for all materials displayed the expected sigmoidal shape with time, with the solid-like behavior rising slowly, then more rapidly, and again slowly to final set. The initial setting time (t(ind)) was found to be approximately 2.8 minutes for the PVS materials and for Impregum Penta and Impregum Penta Soft H, but was significantly longer for the remaining 3 PE low viscosity materials. The solid-like behavior (G') at final set or shear modulus differed among all materials, ranging from 1.0 MPa for Aquasil Decca, 1.69 for Impregum Penta Soft H, and 1.8 MPa for Impregum Penta. G' for low-viscosity materials ranged from 0.66 MPa for Aquasil LV and 0.79 MPa for Permadyne Garant L to 1.2 MPa for Impregum Penta Soft L. The loss tangent at 40 seconds tandelta (t(0)) varied among medium and low viscosity materials, ranging from liquid-like behavior of 4.3 for Permadyne Garant and less than unity or significant solid-like behavior for Impregum Penta. All materials showed tandelta values less than unity at their setting times. The temperature studies revealed significant changes in the kinetics of setting, with the setting time decreasing more than 3-fold between 25 degrees and 37 degrees C for the Aquasil Deca and the Impregum Penta Soft H and more than 2-fold for the Impregum Penta. At room temperature of 25 degrees C, the storage modulus for Impregum Penta Soft H and Aquasil Deca was 1.1% and 37.5% lower than Impregum Penta, respectively. CONCLUSION: The development of the viscoelastic rheological properties with time for 3 medium- and 4 low-viscosity impression materials at 33 degrees C showed significant differences in the setting time and the magnitude of the storage modulus. Compared with Impregum Penta, the new Impregum Penta Soft H was 6% less stiff when set, compared with 44% lower stiffness for the medium viscosity addition silicone. Temperature studies between 25 degrees C and 37 degrees C revealed strong temperature sensitivity of the kinetics of setting and evolution with time of their rheological properties.

Analysis of Variance↗

Effectiveness of couch height-based patient set-up and an off-line correction protocol in prostate cancer radiotherapy.

PURPOSE: To investigate set-up improvement caused by applying a couch height-based patient set-up method in combination with a technologist-driven off-line correction protocol in nonimmobilized radiotherapy of prostate patients. METHODS AND MATERIALS: A three-dimensional shrinking action level correction protocol is applied in two consecutive patient cohorts with different set-up methods: the traditional "laser set-up" group (n = 43) and the "couch height set-up" group (n = 112). For all directions, left-right, ventro-dorsal, and cranio-caudal, random and systematic set-up deviations were measured. RESULTS: The couch height set-up method improves the patient positioning compared to the laser set-up method. Without application of the correction protocol, both systematic and random errors reduced to 2.2-2.4 mm (1 SD) and 1.7-2.2 mm (1 SD), respectively. By using the correction protocol, systematic errors reduced further to 1.3-1.6 mm (1 SD). One-dimensional deviations were within 5 mm for >90% of the measured fractions. The required number of corrections per patient in the off-line correction protocol was reduced significantly during the course of treatment from 1.1 to 0.6 by the couch height set-up method. The treatment time was not prolonged by application of the correction protocol. CONCLUSIONS: The couch height set-up method improves the set-up significantly, especially in the ventro-dorsal direction. Combination of this set-up method with an off-line correction strategy, executed by technologists, reduces the number of set-up corrections required.

Humans↗

Components of attentional set-switching.

A series of distinct event-related potentials (ERPs) have been recorded from the scalp of human subjects as they switch from one task to another. It is possible that task switching may depend on different mechanisms depending on whether the switch requires a change in attentional set, in other words the redirecting of attention to different aspects of a sensory stimulus, or whether it requires a change in intentional set, in others words a change in the way that responses are selected. To address this issue, the current study recorded ERPs while subjects switched between attentional sets and the results were compared with those of a previous investigation in which subjects switched between intentional sets. Subjects selected stimuli according to two conflicting attentional sets, each emphasizing one visual stimulus dimension (colour, shape). Pairs of stimuli, only one of which was to be attended, were presented for between eight and seventeen trials then either a switch or a stay cue was shown. The switch cue instructed subjects to switch from the current attentional set to the other set, while the stay cue instructed subjects to maintain the current set. Comparing ERPs time-locked to the switch and stay cues revealed neural correlates of the initiation of a task switch. Comparing the ERPs time locked to the first stimuli after either stay or switch cues identified neural correlates of the implementation of a task switch. A similar modulation over parietal electrodes was seen when subjects were switching between either attentional or intentional sets. While an intentional set switch began with a medial frontal modulation, attentional set switching began with a lateral frontal modulation. Implementing a new attentional set was associated with modulation of relatively early visual potentials, while implementing a new intentional set was associated with modulation of later response-related potentials. The results confirm that task switching consists of a number of constituent processes which may be taxed to different degrees depending on whether a task-switch paradigm requires subjects to change the way in which they select stimuli or responses.

Attention↗

What should be expected from feature selection in small-sample settings.

MOTIVATION: High-throughput technologies for rapid measurement of vast numbers of biological variables offer the potential for highly discriminatory diagnosis and prognosis; however, high dimensionality together with small samples creates the need for feature selection, while at the same time making feature-selection algorithms less reliable. Feature selection must typically be carried out from among thousands of gene-expression features and in the context of a small sample (small number of microarrays). Two basic questions arise: (1) Can one expect feature selection to yield a feature set whose error is close to that of an optimal feature set? (2) If a good feature set is not found, should it be expected that good feature sets do not exist? RESULTS: The two questions translate quantitatively into questions concerning conditional expectation. (1) Given the error of an optimal feature set, what is the conditionally expected error of the selected feature set? (2) Given the error of the selected feature set, what is the conditionally expected error of the optimal feature set? We address these questions using three classification rules (linear discriminant analysis, linear support vector machine and k-nearest-neighbor classification) and feature selection via sequential floating forward search and the t-test. We consider three feature-label models and patient data from a study concerning survival prognosis for breast cancer. With regard to the two focus questions, there is similarity across all experiments: (1) One cannot expect to find a feature set whose error is close to optimal, and (2) the inability to find a good feature set should not lead to the conclusion that good feature sets do not exist. In practice, the latter conclusion may be more immediately relevant, since when faced with the common occurrence that a feature set discovered from the data does not give satisfactory results, the experimenter can draw no conclusions regarding the existence or nonexistence of suitable feature sets. AVAILABILITY: http://ee.tamu.edu/~edward/feature_regression/

Artificial Intelligence↗

What do hospital decision-makers in Ontario, Canada, have to say about the fairness of priority setting in their institutions?

BACKGROUND: Priority setting, also known as rationing or resource allocation, occurs at all levels of every health care system. Daniels and Sabin have proposed a framework for priority setting in health care institutions called 'accountability for reasonableness', which links priority setting to theories of democratic deliberation. Fairness is a key goal of priority setting. According to 'accountability for reasonableness', health care institutions engaged in priority setting have a claim to fairness if they satisfy four conditions of relevance, publicity, appeals/revision, and enforcement. This is the first study which has surveyed the views of hospital decision makers throughout an entire health system about the fairness of priority setting in their institutions. The purpose of this study is to elicit hospital decision-makers' self-report of the fairness of priority setting in their hospitals using an explicit conceptual framework, 'accountability for reasonableness'. METHODS: 160 Ontario hospital Chief Executive Officers, or their designates, were asked to complete a survey questionnaire concerning priority setting in their publicly funded institutions. Eight-six Ontario hospitals completed this survey, for a response rate of 54%. Six close-ended rating scale questions (e.g. Overall, how fair is priority setting at your hospital?), and 3 open-ended questions (e.g. What do you see as the goal(s) of priority setting in your hospital?) were used. RESULTS: Overall, 60.7% of respondents indicated their hospitals' priority setting was fair. With respect to the 'accountability for reasonableness' conditions, respondents indicated their hospitals performed best for the relevance (75.0%) condition, followed by appeals/revision (56.6%), publicity (56.0%), and enforcement (39.5%). CONCLUSIONS: For the first time hospital Chief Executive Officers within an entire health system were surveyed about the fairness of priority setting practices in their institutions using the conceptual framework 'accountability for reasonableness'. Although many hospital CEOs felt that their priority setting was fair, ample room for improvement was noted, especially for the enforcement condition.

Attitude of Health Personnel↗

Resistance training for strength: effect of number of sets and contraction speed.

PURPOSE: To compare effects on strength in the early phase of resistance training with one or three sets and fast or slow speeds. METHODS: A total of 115 healthy, untrained subjects were randomized to a control group or one of four training groups: one set fast (approximately 140 degrees.s(-1)), three sets fast, one set slow (approximately 50 degrees.s(-1)), or three sets slow. All subjects attended training 3 x wk(-1) for 6 wk. Subjects in the training groups performed unilateral elbow flexion contractions with a target six- to eight-repetition maximum load. Control subjects sat at the training bench but did not train. One repetition maximum strength, arm circumference, and biceps skinfold thickness were measured before and after training. RESULTS: One slow set increased strength by 25% (95% CI 13-36%, P < 0.001). Three sets of training produced greater increases in strength than one set (difference = 23% of initial strength, 95% CI 12-34%, P < 0.001) and fast training resulted in a greater increase in strength than slow training (difference = 11%, 95% CI 0.2-23%, P = 0.046). The interaction between sets and speed was negative (-15%) and of borderline significance (P = 0.052), suggesting there is a benefit of training with three sets or fast speeds, but there is not an additive benefit of training with both. CONCLUSIONS: Three sets of exercise produce twice the strength increase of one set in the early phase of resistance training. Training fast produces greater strength increases than training slow; however, there does not appear to be any additional benefit of training with both three sets and fast contractions.

Adaptation, Physiological↗

Stimulus class formation and concept learning: establishment of within- and between-set generalization and transitive relationships via conditional discrimination procedures.

Three students with moderate mental retardation were taught a complex stimulus class with a two-choice conditional discrimination procedure applied across eight 10-member stimulus sets. Each set was composed of five age-appropriate and five age-inappropriate examples of clothing, accessories, and leisure items (e.g., a Walkman radio). Discrimination training was programmed serially across each set, and generalization probes were conducted concurrently among all sets. Generalization probes consisted of unreinforced conditional matching trials with comparison items being drawn from (a) the set undergoing training (within-set probes), (b) sets not undergoing training (between-set probes), and (c) both sample and comparison items from different sets (transitive stimulus control probes). Results indicate that within-set generalization, between-set generalization, and transitive stimulus relations controlled responding by all 3 students for items that had been contingently associated with reinforcement. However, items that gained control of responding through within-set and between-set generalization alone (i.e., not acquired through contingent reinforcement) remained at baseline levels during transitive stimulus control probes. Results are discussed in terms of a taxonomy of multiple sources of stimulus control that underlie socially defined and maintained stimulus classes.

Adolescent↗

U.S. Food Safety and Inspection Service testing for Salmonella in selected raw meat and poultry products in the United States, 1998 through 2003: analysis of set results.

The U.S. Food Safety and Inspection Service (FSIS) tests sets of samples of selected raw meat and poultry products for Salmonella to ensure that federally inspected establishments meet performance standards defined in the pathogen reduction-hazard analysis and critical control point system (PR-HACCP) final rule. In the present report, sample set results are described and associations between set failure and set and establishment characteristics are identified for 4,607 sample sets collected from 1998 through 2003. Sample sets were obtained from seven product classes: broiler chicken carcasses (n = 1,010), cow and bull carcasses (n = 240), market hog carcasses (n = 560), steer and heifer carcasses (n = 123), ground beef (n = 2,527), ground chicken (n = 31), and ground turkey (n = 116). Of these 4,607 sample sets, 92% (4,255) were collected as part of random testing efforts (A sets), and 93% (4,166) passed. However, the percentage of positive samples relative to the maximum number of positive results allowable in a set increased over time for broilers but decreased or stayed the same for the other product classes. Three factors associated with set failure were identified: establishment size, product class, and year. Set failures were more likely early in the testing program (relative to 2003). Small and very small establishments were more likely to fail than large ones. Set failure was less likely in ground beef than in other product classes. Despite an overall decline in set failures through 2003, these results highlight the need for continued vigilance to reduce Salmonella contamination in broiler chicken and continued implementation of programs designed to assist small and very small establishments with PR-HACCP compliance issues.

Animals↗