Studies on the inhibition of intestinal absoprtion of radioactive strontium. VI. Alginate degradation products as potent in vivo sequestering agents of radioactive strontium.
Explore the source record for details and available documents.
SEARCH · Search PubMed
Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
In experiments on CBA X C57B16 mice a study was made of the acute effects of radiocarbon (14C-glycine) administered intraperitoneally in doses of 130, 60, 30 and 15 mBq/animal (the total cumulative doses absorbed within the body were, at an average, 29.5, 14.2, 7.1 and 3.6 Gy, respectively). In the first group, the animals developed grave radiation affections (50% death, average life-span of 17.6 days); in the second group, the affection was less serious, and in the third and fourth groups, the affection was light. A mean tissue absorbed dose in the died animals was 6-11 Gy.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Past atmospheric nuclear testing which have been conducted frequently, have caused environmental pollution due to the diffusion of radioactive substances into the atmosphere and from the radioactive fallout. The environmental pollution from nuclear testing into the atmosphere has resulted in the radioactive contamination in agricultural products and has continued for a long time. The radioactive contamination of agricultural products occurs through air, water and soil which were contaminated by radioactive fallout. In this paper, for the purpose of analyzing the extent of the radioactive contamination levels in the agricultural products of Saitama Prefecture, spinach, green soybeans, dried shiitake and welsh onion, were selected among products, as the amount of the harvest is abundant in all of Japan. Radioactivity concentration was investigated by gamma ray spectrometry and radiochemical analysis. The radioactivity concentrations of artificial radioactive nuclides, cesium-137 (137Cs) and strontium-90 (90Sr), were detected in the range which is considered to be the result of radioactive fallout. Moreover, in order to examine the effect on radioactivity concentrations in agricultural products by culinary processing, the raw agricultural products were boiled, and their radioactivity concentrations were compared with the raw produce. The radioactivity concentrations in the boiled were lower than those in the raw produce.
N-(2-(4-(2-Methoxy-phenyl)-1-piperazin-1-yl)ethyl)-N-(2-pyridyl)++ +cyclohexanecarboxamide (WAY-100635), labelled in its amido carbonyl group with 11C (t1/2 = 20.4 min), is a promising radioligand for the study of brain 5-HT1A receptors with positron emission tomography (PET). Thus, in PET experiments in six cynomolgus monkeys and seven healthy male volunteers, [carbonyl-11C]WAY-100635 was taken up avidly by brain. Radioactivity was retained in regions rich in 5-HT1A receptors, such as occipital cortex, temporal cortex and raphe nuclei, but cleared rapidly from cerebellum, a region almost devoid of 5-HT1A receptors. [Carbonyl-11C]WAY-100635 provides about 3- and 10-fold higher signal contrast (receptor-specific to nonspecific binding) than [O-methyl-11C]WAY-100635 in receptor-rich areas of monkey and human brain, respectively. To elucidate the effect of label position on radioligand behaviour and to aid in the future biomathematical interpretation of the kinetics of regional cerebral radioactivity uptake in terms of receptor-binding parameters, HPLC was used to measure [carbonyl-11C]WAY-100635 and its radioactive metabolites in plasma at various times after intravenous injection. Radioactivity cleared rapidly from monkey and human plasma. Parent radioligand represented 19% of the radioactivity in monkey plasma at 47 min and 8% of the radioactivity in human plasma at 40 min. [Carbonyl-11C]desmethyl-WAY-100635 was below detectable limits in monkey plasma and at most a very minor radioactive metabolite in human plasma. [11C]Cyclohexanecarboxylic acid was identified as a significant radioactive metabolite. In human plasma this maximally represented 21% of the radioactivity at 10 min after radioligand injection. All other major radioactive metabolites in monkey and human plasma were even more polar. No-carrier-added [carbonyl-11C]cyclohexanecarboxylic acid was prepared in the laboratory and after intravenous administration into cynomolgus monkey was shown with PET to give only a low uptake of radioactivity into brain tissue. The acid rapidly gave rise to several radioactive metabolites of higher polarity in plasma. The observed lack of any significant metabolism of [carbonyl-11C]WAY-100635 to highly lipophilic or pharmacologically potent radioactive compounds is consistent with its high signal contrast in primate brain.
OBJECTIVE: To determine the optimal radioactive colloid injection technique for sentinel lymph node (SLN) biopsy for breast cancer. SUMMARY BACKGROUND DATA: The optimal radioactive colloid injection technique for breast cancer SLN biopsy has not yet been defined. Peritumoral injection of radioactive colloid has been used in most studies. Although dermal injection of radioactive colloid has been proposed, no published data exist to establish the false-negative rate associated with this technique. METHODS: The University of Louisville Breast Cancer Sentinel Lymph Node Study is a multiinstitutional study involving 229 surgeons. Patients with clinical stage T1-2, N0 breast cancer were eligible for the study. All patients underwent SLN biopsy, followed by level I/II axillary dissection. Peritumoral, subdermal, or dermal injection of radioactive colloid was performed at the discretion of the operating surgeon. Peritumoral injection of isosulfan blue dye was performed concomitantly in most patients. The SLN identification rates and false-negative rates were compared. The ratios of the transcutaneous and ex vivo radioactive SLN count to the final background count were calculated as a measure of the relative degree of radioactivity of the nodes. One-way analysis of variance and chi-square tests were used for statistical analysis. RESULTS: A total of 2,206 patients were enrolled. Peritumoral, subdermal, or dermal injection of radioactive colloid was performed in 1,074, 297, and 511 patients, respectively. Most of the patients (94%) who underwent radioactive colloid injection also received peritumoral blue dye injection. The SLN identification rate was improved by the use of dermal injection compared with subdermal or peritumoral injection of radioactive colloid. The false-negative rates were 9.5%, 7.8%, and 6.5% (not significant) for peritumoral, subdermal, and dermal injection techniques, respectively. The relative degree of radioactivity of the SLN was five- to sevenfold higher with the dermal injection technique compared with peritumoral injection. CONCLUSIONS: Dermal injection of radioactive colloid significantly improves the SLN identification rate compared with peritumoral or subdermal injection. The false-negative rate is also minimized by the use of dermal injection. Dermal injection also is associated with SLNs that are five- to sevenfold more radioactive than with peritumoral injection, which simplifies SLN localization and may shorten the learning curve.