Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Quartz”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13Linked to original sources

In vitro action of quartz on alveolar macrophage lipid peroxides.

The in vitro effects of quartz particles on the lipid peroxide rate were measured on guinea pig pulmonary alveolar macrophages (PAMs). As controls, either PAMs alone or exposed to inert dust were used. The amount of lipid peroxide resulting after one-hour incubation was determined by means of the thiobarbituric acid test (TBA). The results showed that quartz induced a substantial increase of lipid peroxide in PAMs compared with both samples (dust-free or exposed to corundum). The influence of pretreatment of quartz by polyvinylpyridine-N-oxide (PVPNO) and by mineral water containing carbonate and chloride ions was also studied.

Adult↗

Contrasting respirable quartz and kaolin retention of lecithin surfactant and expression of membranolytic activity following phospholipase A2 digestion.

Respirable-sized quartz, a well-established fibrogenic mineral dust, is compared with kaolin in erythrocyte hemolysis assays after treatment with saline dispersion of dipalmitoyl phosphatidylcholine, a primary phospholipid component of pulmonary surfactant. Both dusts are rendered inactive after treatment, but the membranolytic activity is partly to fully restored after treatment with phospholipase A2, an enzyme normally associated with cellular plasma membranes and lysosomes. Phospholipid-coated dusts were incubated for periods of 2-72 h at a series of applied enzyme concentrations, and the adsorbed lipid species and hemolytic activity were quantitated at each time for both dusts. Surfactant was lost more readily from quartz than from kaolin, with consequent more rapid restoration of mineral surface hemolytic activity for quartz. Interactions of surfactant and mineral surface functional groups responsible for the mineral-specific rate differences, and implications for determining the mineral surface bioavailability of silica and silicate dusts, are discussed.

1,2-Dipalmitoylphosphatidylcholine↗

Antioxidant activity of tetrandrine and its inhibition of quartz-induced lipid peroxidation.

Tetrandrine is a benzylisoquinoline alkaloid that has been used in China as an antifibrotic drug to treat the lesions of silicosis. Its mechanism in the treatment of silicosis is unclear. Electron spin resonance (ESR) spin trapping was employed to investigate the antioxidant properties of tetrandrine. The spin trap used was 5,5-dimethyl-1-pyrroline N-oxide (DMPO). Tetrandine efficiently reacted with hydroxyl (.OH) radicals with a reaction rate of approximately 1.4 x 10(10) M-1 s-1. The .OH radicals were generated by the Fenton reaction [Fe(II) + H2O2) as well as by reaction of chromium(V) with H2O2. Similar results were obtained using .OH radicals generated by reaction of freshly fractured quartz particles with aqueous medium. Tetrandrine also scavenged superoxide (O2-) radicals produced from xanthine/xanthine oxidase. The effect of tetrandrine on lipid peroxidation induced by freshly fractured quartz particles was evaluated using linoleic acid as a model lipid. The results showed that tetrandrine caused a significant inhibition on freshly fractured quartz-induced lipid peroxidation.

Alkaloids↗

Investigation of the orientation of purple membrane sheets in Langmuir-Blodgett films by a quartz crystal microbalance.

By means of the quartz crystal microbalance (QCM), a convenient method was developed to determine the degree of orientation of purple membrane (PM) sheets on the air/water interface. Langmuir-Blodgett films from both wild-type and SH-mutant PM (bR D36C) were vertically deposited on the surface of gold-sputtered AT-cut quartz crystals. The shift of resonance frequency of the QCM during a special washing protocol allowed us to differentiate between physically adsorbed PM fragments and any PM attached to the gold surface via chemical bonds. By washing with organic solvents, complete desorption of the wild-type PM was achieved, whereas for the SH-mutant, approximately 60% of the PM fragments could not be detached from the surface. These PM sheets should be oriented with the cytoplasmic side facing the water subphase to that their SH-groups can chemically bind to the gold surface of the quartz plate.

Adsorption↗

Time-resolved luminescence from annealed quartz.

The influence of annealing on the lifetime and luminescence intensity has been studied in quartz annealed at 873, 1073, 1173, and 1273 K and in unannealed quartz. Luminescence was stimulated by pulsed green (525 nm) light. Luminescence intensity increased as a function of temperature from 293 K to a peak at 373 K, and decreased thereafter to 473 K, the maximum temperature in the investigations. Luminescence lifetimes from both unannealed quartz and samples annealed at 873 K for up to 5 min were constant at about 40 micros below 373 K. Lifetimes decreased strictly monotonically with temperature in samples annealed above 873 K. Values of the activation energy for thermal assistance accounting for the increase in luminescence intensity, and of thermal quenching describing the decrease of luminescence intensity and luminescence lifetimes are presented.

Hot Temperature↗

Luminescence quartz dating of lime mortars. A first research approach.

Lime mortars mixed with sand are well suited for connecting structural materials, like stones and bricks, due to the mechanical properties this material exhibits. Their extensive use in architectural and decorative works during the last 4000 years motivated the introduction of the 'Luminescence clock' for age determination of mortars. The same principles as for quartz optically stimulated luminescence (OSL) dating of sediments were applied for age estimation of a mortar fragment removed from a Byzantine church monument dated by archaeological means to 1050-1100 years ago (the first half of the 10th century). The OSL from the quartz was monitored under blue light stimulation and UV detection, using a single-aliquot-regenerative-dose protocol. The quartz-OSL dating of the mortar resulted in 870 +/- 230 a. TL polymineral fine grain dating was also performed on a brick fragment which was connected to the mortar, resulting in a TL age of 1095 +/- 190 a.

Calcium Compounds↗

A comprehensive comparative study of the predose effect for three quartz crystals of different origin.

The study of the thermoluminiscence (TL) sensitivity of quartz due to heat and irradiation treatments is of importance in dating and retrospective dosimetry. A comprehensive comparative study of the predose effect was carried out for three types of quartz of different origin. Complete TL vs. dose and sensitivity S vs. predose curves were obtained for the dose range of 0.1 < D < 400 Gy. Additional complete sensitivity vs. predose curves were obtained for samples which underwent a combined predose irradiation and a subsequent heat treatment to 500 degrees C. Although the TL vs. dose curves showed very different behaviours, the sensitivity vs. predose curves showed several common characteristics. The sensitivity vs. predose curves showed abrupt changes approximately 10 Gy. The sensitivity after a combined predose irradiation and heat treatment to 500 degrees C showed a very gradual change in the whole dose range studied. These results are explained qualitatively by using the modified Zimmerman model for quartz.

Computer Simulation↗

Theoretical modelling of experimental diagnostic procedures employed during pre-dose dosimetry of quartz.

The pre-dose technique in thermoluminescence (TL) is used for dating archaeological ceramics and for accident dosimetry. During routine applications of this technique, the sensitisation of the quartz samples is measured as a function of the annealing temperature, yielding the so-called thermal activation characteristic (TAC). The measurement of multiple TACs and the study of the effect of UV-radiation on the TL sensitivity of quartz are important analytical and diagnostic tools. In this paper, it is shown that a modified Zimmerman model for quartz can successfully model the experimental steps undertaken during a measurement of multiple TACs.

Algorithms↗

Usability of VTL from natural quartz grains for retrospective dosimetry.

To develop retrospective dosimetry of unexpected radiation accident, basic studies on violet thermoluminescence (VTL) phenomena were conducted using natural quartz grains. All VTL glowcurves of as-received samples did not exhibit peaks <250 degrees C, although for artificially irradiated quartz samples there were VTL peaks in the temperature region <250 degrees C. Therefore, accident doses could be estimated without the interference of naturally accumulated doses by VTL measurements from natural quartz. The mean lives of VTL were evaluated by the various heating rates method and the range of values was found to be between some days and ten thousands of years depending on each peak. Especially, the mean life of VTL peak at 200 degrees C was years order. Furthermore, the lower detection limit was calculated to be tens of mGy from the response curve. This value was lower than that of other methods such as ESR dosimetry. From these results, we conclude that VTL dosimetry can be preferred for accidental evaluation.

Electrons↗

Novel instrumentation monitoring in situ platelet adhesivity with a quartz crystal microbalance.

The quartz crystal microbalance (QCM) in a solution is capable of sensing an extremely small mass change in the nanogram range. In this article, the authors attempted to apply QCM to in situ continuous monitoring of platelet adhesion in plasma. The instrumentation consisted of a piezoelectric quartz crystal vacuum-deposited with gold and connected to two electrodes, an oscillation circuit, a frequency counter, and a DC source (5 V), coupled with a personal computer, a television monitor, and a printer. The authors noted resonant frequency shifts to determine weight increase upon cell adhesion. A QCM sensor, with the sensitivity of 1 ng/Hz, was placed horizontally in platelet poor plasma. The authors did not observe any measurable frequency shift upon adding a suspension of non-adherent cells, such as red blood cells and prostaglandin I2-sensitized platelets, indicating that QCM does not count the increase in the mass of cells that simply settled on the quartz. They did observe, however, a time-dependent frequency shift upon addition of platelet rich plasma. Coupled with visual determination of numbers of adherent platelets and their morphology under scanning electron microscopy, they found that the magnitude of shift and its time dependence seem to correlate not only numbers of adherent platelets, but to their spreading state, indicating that QCM detects only the weight at the focal contact region of adherent cells. This suggested that the former contributes to the early phase of the frequency shift, and the latter contributes to a shift change after a longer period of incubation.(ABSTRACT TRUNCATED AT 250 WORDS)

Amino Acid Sequence↗

Chirality of quartz. Fibrosis and tumour development in dust inoculated mice.

Dextro (d) and laevo (l) forms of quartz dust was inoculated intranasally and subcutaneously into 2-month-old (C57 x BALB/c)F1 mice which were killed 18 months later. Both d and l quartz caused fibrosis, liver nodule formation and an enhanced incidence of lymphoma/leukemia. However, the tumour incidence was significantly higher in l than in d quartz dust-treated animals. It is concluded that in addition to effects clearly independent of chirality there is evidence that the biological response to nonidentical mirror images of solid crystals may differ.

Administration, Intranasal↗

Effects of a liquid layer on thickness-shear vibrations of rectangular AT-cut quartz plates.

Thickness-shear vibrations of a rectangular AT-cut quartz with one face in contact with a layer of Newtonian (linearly viscous and compressible) fluid are studied. The two-dimensional (2-D) governing equations for vibrations of piezoelectric crystal plates given previously are used in the present study. The solutions for 1-D shear wave and compressional wave in a liquid layer are obtained, and the stresses at the bottom of the liquid layer are used as approximations to the stresses exerting on the crystal surface in the plate equations. Closed form solutions are obtained for both free and piezoelectrically forced thickness-shear vibrations of a finite, rectangular AT-cut quartz in contact with a liquid layer of finite thickness. From the present solutions, a simple and explicit formula is deduced for the resonance frequency of the fundamental thickness-shear mode, which includes the effects of both shear and compressional waves in the liquid layer and the effect of the thickness-to-length ratio of the crystal plate. The formula reduces to the widely used frequency equation obtained by many previous investigators for infinite plates. The resonance frequency of a rectangular AT-cut quartz, computed as a function of the thickness of the adjacent liquid layer, agrees closely with the experimental data measured by Schneider and Martin.

Computer Simulation↗

Frequency interference between two mesa-shaped quartz crystal microbalances.

The multichannel quartz crystal microbalance (MQCM) is very attractive for biosensor applications. The principle of the MQCM design involves fabricating arrays of quartz microbalances on a single substrate, and it is important that the individual sensor performance is not influenced by the neighboring devices. Feasible ways to control the coupling of acoustical energy within a MQCM structure are to increase the difference in the resonance frequency between the electroded and unelectroded portions of the substrate; and a practical way to achieve this is to use mesa structures. In this paper, the frequency interference between two mesa-shaped quartz crystal microbalances is investigated using Mindlin's theory. The results show that even a very small mesa height (approximately 5% of the plate thickness) can greatly reduce the frequency interference and more effectively trap the acoustic energy. This allows for a broader design window and higher packing density for MQCM applications.

Biosensing Techniques↗

Quartz-induced production of reactive oxygen metabolites by activated human monocyte-derived macrophages.

Quartz but not titanium dioxide (TiO2) induced the production of reactive oxygen metabolites (ROM) by human monocyte-derived macrophages, as measured by lucigenin dependent chemiluminescence. Activation of the macrophages with BCG, bacterial lipopolysaccharide and macrophage-activating factor (MAF) caused a prominent increase of quartz-induced ROM production, MAF having the strongest effect. The activation did not affect the TiO2 responses to the same extent. Assuming that ROM have a role in the pathogenesis of silica-induced disease in man, we suggest that enhancement of quartz-induced production of ROM by activated pulmonary macrophages may at least partly explain the experimental and epidemiological data indicating that activation of the immune system during infection promotes the development of silicosis.

Humans↗

Erbium: yttrium-aluminum-garnet laser induced vapor bubbles as a function of the quartz fiber tip geometry.

BACKGROUND: The use of modern erbium: yttrium-aluminum-garnet (YAG) laser systems in opthalmic microsurgery requires a precise knowledge of the size and dynamics of the laser induced vapor bubbles. The aim of this work was to clarify the possibilities of controlling the vapor bubble shape and size by using an optimized fiber tip geometry for various ophthalmic applications with the erbium: YAG laser. METHODS: The mid-infrared radiation of free-running erbium: YAG laser was coupled optically into means of different low OH(-) quartz fiber tips to investigate the vapor bubble formation in water by high-speed photography. The core diameter of four fiber tips ranged from 200 up to 940 microm. Fourteen fiber tips were polished at an angle graduated from 10 degrees to 70 degrees over the full core diameter (seven fiber tips) and over the half core diameter (seven fiber tips). Three fiber tips were produced to have a curvature at the distal end with curvature radii of 160, 230, and 420 microm. RESULTS: The shape as well as the size of erbium: YAG laser induced vapor bubbles can be controlled systematically by using adequate fiber tip geometries. In detail, the used different angles and curvatures demonstrate that the propagation direction of the vapor bubbles can be estimated by optical modeling considering Snell's law and the Fresnel laws at a quartz-air boundary. Beside this, the size of a vapor bubble can be predetermined by choosing ideal fiber tip geometries to reduce or increase the radiant exposure at the distal end of the quartz fiber tip. CONCLUSIONS: The good possibility of controlling the shape and size of vapor bubbles offers a wider range of new applications, especially in ophthalmic microsurgery such as erbium YAG laser vitrectomy.

Equipment Design↗

Persistent biological reactivity of quartz in the lung: raised protease burden compared with a non-pathogenic mineral dust and microbial particles.

This study assessed the potential harmfulness of particles in the lung by measuring their ability to elicit and maintain an inflammatory response and to damage lung tissue. It compared the inflammogenicity of two nondurable, biological particulates (Corynebacterium parvum and zymosan) with a pathogenic mineral dust (quartz) and a nonpathogenic dust (titanium dioxide) by dosing rats via the intratracheal route and measuring the consequent alveolitis. The magnitude and duration of the inflammatory response were assessed by measuring the total number of leucocytes and the percentage of neutrophils obtained by bronchoalveolar lavage. Two key functional parameters of the lavaged leucocytes--ability to degrade fibronectin and production of plasminogen activator--were also measured. A marked inflammatory response had occurred by one day after instillation, characterised by increases in total leucocyte numbers and percentage of neutrophils in the bronchoalveolar lavages, with all four test materials. In all but the quartz exposed animals, the inflammation subsided rapidly thereafter, approaching control levels by 15 days after injection; in the quartz exposed animals the alveolitis persisted for up to 30 days. All of the inflammogens generated chemotaxins in rat serum in vitro and so, by analogy, might also be expected to generate chemotactic activity in alveolar lining fluid which could contribute to the generation of an inflammatory response. The cellular inflammatory response was accompanied by a concomitant increase in the proteolytic activity of the bronchoalveolar lavage leucocytes but production of plasminogen activator remained unchanged. In vitro exposure to the inflammogens had no effect on the proteolytic activity against fibronectin or on the plasminogen activator activity of bronchoalveolar leucocytes.

Animals↗

Radiographic abnormalities among construction workers exposed to quartz containing dust.

BACKGROUND: Construction workers are exposed to quartz containing respirable dust, at levels that may cause fibrosis in the lungs. Studies so far have not established a dose-response relation for radiographic abnormalities for this occupational group. AIMS: To measure the extent of radiographic abnormalities among construction workers primarily exposed to quartz containing respirable dust. METHODS: A cross sectional study on radiographic abnormalities indicative of pneumoconiosis was conducted among 1339 construction workers mainly involved in grinding, (jack)-hammering, drilling, cutting, sawing, and polishing. Radiological abnormalities were determined by median results of the 1980 International Labour Organisation system of three certified "B" readers. Questionnaires were used for assessment of occupational history, presence of respiratory diseases, and symptoms and smoking habits. RESULTS: An abnormality of ILO profusion category 1/0 and greater was observed on 10.2% of the chest radiographs, and profusion category of 1/1 or greater on 2.9% of the radiographs. The average duration of exposure of this group was 19 years and the average age was 42. The predominant type of small opacities (irregularly shaped) is presumably indicative of mixed dust pneumoconiosis. The prevalence of early signs of nodular silicosis (small rounded opacities of category 1/0 or greater) was low (0.8%). CONCLUSIONS: The study suggests an elevated risk of radiographic abnormalities among these workers with expected high exposure. An association between radiographic abnormalities and cumulative exposure to quartz containing dust from construction sites was observed, after correction for potentially confounding variables.

Adult↗

Quartz but not iron oxide causes air-flow obstruction, emphysema, and small airways lesions in the rat.

Recent epidemiologic studies have suggested that some workers exposed to inorganic dusts develop air-flow obstruction independent of or greater than that produced by cigarette smoke; the morphologic basis of this effect is unknown. To investigate this problem, we administered saline alone, 10 mg iron oxide (an inert dust), or 10 or 30 mg of quartz to rats by intratracheal instillation. Animals were killed after 30 days, and pulmonary function and morphologic changes were examined. The iron oxide group was similar to the saline control group in all functional and morphometric parameters. However, both quartz-exposed groups showed evidence of air-flow obstruction, with more severe abnormalities in the high dose group. These findings correlated with morphometric observations of emphysema and thickened airway walls, with changes again more severe in the high dose group. Early silicotic nodules were also present in the latter animals. We conclude that in addition to the classic lesions of nodular silicosis, quartz can produce morphologic and functional changes of air-flow obstruction; no such changes are seen with iron oxide. These observations may explain the air-flow obstruction seen in workers exposed to mineral dusts.

Airway Obstruction↗