Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “PIPET”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13Linked to original sources

Viscosity of passive human neutrophils undergoing small deformations.

At issue is the type of constitutive equation that can be used to describe all possible types of deformation of the neutrophil. Here a neutrophil undergoing small deformations is studied by aspirating it into a glass pipet with a diameter that is only slightly smaller than the diameter of the spherically shaped cell. After being held in the pipet for at least seven seconds, the cell is rapidly expelled and allowed to recover its undeformed, spherical shape. The recovery takes approximately 15 s. An analysis of the recovery process that treats the cell as a simple Newtonian liquid drop with a constant cortical (surface) tension gives a value of 3.3 x 10(-5) cm/s for the ratio of the cortical tension to cytoplasmic viscosity. This value is about twice as large as a previously published value obtained with the same model from studies of large deformations of neutrophils. This discrepancy indicates that the cytoplasmic viscosity decreases as the amount of deformation decreases. An extrapolated value for the cytoplasmic viscosity at zero deformation is approximately 600 poise when a value for the cortical tension of 0.024 dyn/cm is assumed. Clearly the neutrophil does not behave like a simple Newtonian liquid drop in that small deformations are inherently different from large deformations. More complex models consisting either of two or more fluids or multiple shells must be developed. The complex structure inside the neutrophil is shown in scanning electron micrographs of osmotically burst cells and cells whose membrane has been dissolved away.

Biophysical Phenomena↗

Gamma-dendrotoxin blocks large conductance Ca2+-activated K+ channels in neuroblastoma cells.

In N1E 115 neuroblastoma cells, gamma-dendrotoxin (DTX, 200 nM) blocked the outward K(+) current by 31.1 +/- 3.5% (n = 4) with approximately 500 nM Ca(2+) in the pipet solution, but had no effect on the outward K(+) current when internal Ca(2+) was reduced. Using a ramp protocol, iberiotoxin (IbTX, 100 nM) inhibited a component of the whole cell current, but in the presence of 200 nM gamma-DTX, no further inhibition by IbTX was observed. Two types of single channels were seen using outside-out patches when the pipette free Ca(2+) concentration was approximately 500 nM; a 63 pS and a 187 pS channel. The 63 pS channel was TEA-, IbTX- and gamma-DTX-insensitive, while the 187 pS channel was blocked by 1 mM TEA, 100 nM IbTX or 200 nM gamma-DTX. Both channels were activated by external application of ionomycin, when the pipet calcium concentration was reduced. gamma-DTX (200 nM) reduced the probability of openings of the 187 pS channel, with an IC(50) of 8.5 nM. In GH(3) cells gamma-DTX (200 nM) also blocked an IbTX-sensitive component of whole-cell K(+) currents. These results suggest that gamma-DTX blocks a large conductance Ca(2+) activated K(+) current in N1E 115 cells. This is the first indication that any of the dendrotoxins, which have classically been known to block voltage-gated (Kv) channels, can also block Ca(2+) activated K(+) channels.

Animals↗

IP3 production in A10 cells, an established aortic smooth muscle cultured cell line: effects of agonist administration procedure and culture conditions.

1. After normal culture (10% FBS), medium exchange itself evoked marked increases in IP3 levels in A10 cells that masked the net change in IP3 in response to vasopressin (100 nM). 2. Low-serum (0.3% FBS) culture for 10 days abolished the increase in IP3 by medium exchange, and increased expression of cGMP kinase. 3. Stimulation of cells with vasopressin (100 nM) by a pipetting procedure, increased IP3 levels irrespective of culture conditions. 4. This cell line therefore could be used in a contractile form (after low-serum culture) with pipetting procedure to observe IP3 response, especially with regard to interactions with the cGMP signaling system.

Animals↗

Estimation of uncertainty in kinetic-colorimetric assay of bacterial endotoxins.

The relative standard deviation (R.S.D.) of measurements is estimated in the kinetic-colorimetric assay of bacterial endotoxins without recourse to the usual repeated experiments. The measurements are the slopes of kinetic curves and two major factors are considered to cause the uncertainty of the measurements: (1) the pipetting of the sample and color development reagent; and (2) noise in the detection unit. The measurement R.S.D. is formulated as a function of endotoxin concentration. Two parameters (S.D. of the pipetted volumes and S.D. of the detector noise) are also required in the uncertainty equation, but no arbitrary coefficients are included. Since the S.D. values for pipettes and detector noise can be determined independently of the endotoxin assays, the measurement R.S.D. can be estimated by the above equation without repeating the assays. However, the calibration curve is necessary. The theoretical estimation is shown to be in good agreement with the experimental R.S.D. (n = 12) over a wide concentration range.

Algorithms↗

Evaluation of a new automated microneutralization assay for the quantitative detection of neutralizing antibodies against enteroviruses.

An automated microneutralization assay for the quantitative detection of neutralizing antibodies (NA) against polioviruses and non-polio enteroviruses (NPEV) using a pipetting roboter (Tecan RSP 5072) was established and compared to the conventional manually performed test procedure. The qualitative neutralizing antibody detection was not significantly influenced by the assay system (manual or automated assay). Concerning the quantitative antibody detection, two-fold titre differences between the two test systems were observed in only 2.3% of the 260 serum samples investigated. The intra-assay and inter-assay variability of the quantitative detection of neutralizing antibodies using the automated assay proved to be very low. The quantitative detection of neutralizing antibodies using an automated pipetting robot permitted the testing of large numbers of samples within a shorter period and with less labour intensity as compared to the manually performed assay. Therefore it represents a valuable alternative to the conventional microneutralization test, especially for the serodiagnosis of non-polio enterovirus infections in large sample collectives, assessment of immunity to polioviruses and for seroepidemiological surveys.

Animals↗

Continuous monitoring of L-glutamate released from cultured nerve cells by an online sensor coupled with micro-capillary sampling.

A small volume L-glutamate online sensor was developed in order to monitor changes in the local concentration of L-glutamate released from cultured nerve cells. Syringe pump in the suction mode is used to sample extracellular fluid continuously from a glass micro-capillary and the concentration of L-glutamate can be determined by using a glassy carbon (GC) electrode modified with an Os-polyvinylpyridine mediator bottom film containing horseradish peroxidase and a bovine serum albumin top layer containing L-glutamate oxidase. The overall efficiency of L-glutamate detection with a sensor is 71% under optimum conditions due to an efficient enzymatic reaction at the modified electrode in the thin layer radial flow cell. As a result, we achieved a detection limit of 7-15 nM and a linear range of 50 nM to 10 microM. In an in vitro experiment, the extracellular fluid near a particular nerve cell can be sampled with this micro-pipet and continuously introduced into the modified GC electrode in the radial flow cell via suction provided by a syringe pump. The nerve cells are stimulated by the KCl in a glass capillary and the L-glutamate concentration change can be monitored by changing the distance between the sampling pipet and the nerve cells.

Animals↗

Determination of beta-2 microglobulin levels in plasma using a high-throughput mass spectrometric immunoassay system.

A high-throughput mass spectrometric immunoassay (MSIA) system for the analysis of proteins directly from biological fluids is reported. A 96-well-format robotic workstation equipped with antibody-derivatized affinity pipet tips was used for the parallel extraction of specific proteins from samples and subsequent deposition onto 96-well arrayed matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) targets. Interferences from nonspecifically bound proteins were minimized through choice of appropriate affinity pipet tip derivatization chemistries. Sample preparation for MALDI-TOFMS was enhanced through the use of hydrophobic/hydrophilic contrasting targets, which also presented functionalities found to promote matrix/analyte crystal growth. Automated mass spectrometry was used in the unattended acquisition of data, resulting in an analysis rate of approximately 100 samples/h (biological fluid-->data). The quantitative MSIA of beta2m levels present in human plasma samples is given as illustration.

Adult↗

Programmable delivery of DNA through a nanopipet.

We report the pulsed delivery of single-stranded DNA molecules through a nanopipet. The conical geometry of the pipet leads to a localized electric field, since all of the potential drop occurs in the tip region. Pulsatile delivery of DNA molecules can be achieved in an experimentally simple way with high precision by controlling the applied voltage. Single-molecule detection and fluorescence correlation spectroscopy in the nanopipet enable us to determine the number of molecules delivered. Anomalous slow diffusion of the DNA molecules in the pipet has also been observed. This nanopumping technique may have potential applications in local drug delivery and nanofabrication of biomolecules on surfaces in aqueous environments.

DNA↗

Demonstration of direct bioanalysis of drugs in plasma using nanoelectrospray infusion from a silicon chip coupled with tandem mass spectrometry.

Quantitative bioanalysis by direct nanoelectrospray infusion coupled to tandem mass spectrometry has been achieved using an automated liquid sampler integrated with an array of microfabricated electrospray nozzles allowing rapid, serial sample introduction (1 min/ sample). Standard curves prepared in human plasma for verapamil (r2 = 0.999) and its metabolite norverapamil (r2 = 0.998) were linear over a range of 2.5-500 ng/ mL. Based on the observed precision and accuracy, a lower limit of quantitation of 5 ng/mL was assigned for both analytes. Sample preparation consisted of protein precipitation with an organic solvent containing the structural analogue gallopamil as an internal standard. Protein precipitation was selected both to maximize throughput and to test the robustness of direct nanoelectrospray infusion. Aliquots of supernatant (10 pL) were transferred to the back plane of the chip using disposable, conductive pipet tips for direct infusion at a flow rate of 300 nL/min. Electrospray ionization occurred from the etched nozzles (30-microm o.d.) on the front of the chip, initiated by a voltage applied to the liquid through the pipet tip. The chip was positioned near the API sampling orifice of a triple quadrupole mass spectrometer, which was operated in selected reaction monitoring mode. Results are presented that document the complete elimination of system carry-over, attributed to lack of a redundant fluid path. This technology offers potential advantages for MS-based screening applications in drug discovery by reducing the time for methods development and sample analysis.

Drug Monitoring↗

Stop and go extraction tips for matrix-assisted laser desorption/ionization, nanoelectrospray, and LC/MS sample pretreatment in proteomics.

Proteomics is critically dependent on optimal sample preparation. Particularly, the interface between protein digestion and mass spectrometric analysis has a large influence on the overall quality and sensitivity of the analysis. We here describe a novel procedure in which a very small disk of beads embedded in a Teflon meshwork is placed as a microcolumn into pipet tips. Termed Stage, for STop And Go Extraction, the procedure has been implemented with commercially available material (C18 Empore Disks (3M, Minneapolis, MN)) as frit and separation material. The disk is introduced in a simple and fast process yielding a convenient and completely reliable procedure for the production of self-packed microcolumns in pipet tips. It is held in place free of obstacles solely by the narrowing tip, ensuring optimized loading and elution of analytes. Five disks are conveniently placed in 1 min, adding <0.1 cent in material costs to the price of each tip. The system allows fast loading with low backpressure (>300 micro/min for the packed column using manual force) while eliminating the possibility of blocking. The loading capacity of C18-StageTips (column bed: 0.4 mm diameter, 0.5 mm length) is 2-4 microg of protein digest, which can be increased by using larger diameter or stacked disks. Five femtomole of tryptic BSA digest could be recovered quantitatively. We have found that the Stage system is well-suited as a universal sample preparation system for proteomics.

Animals↗

Precision, limit of detection and range of quantitation in competitive ELISA.

This paper develops a mathematical model for describing the within-plate variation as the RSD (relative standard deviation) of absorbance measurements in a wide concentration range in competitive ELISA and proposes a method for determining the limit of detection (LOD) and range of quantitation (ROQ). The ELISA for 17 alpha-hydroxyprogesterone is taken as an example. The theoretical RSD description involves analyte concentration as an independent variable and error sources as parameters which concern the pipetting and absorbance measurement. Our model can dispense with repeated experiments of real samples, but the error parameters should be determined experimentally. The theory is in good agreement with the experiments. The most influential error sources at low and high sample concentrations are shown to be the pipetting of a viscous solution of antiserum and the absorbance inherent to the wells of a plate, respectively. The LOD and ROQ are defined as the concentration with 30% RSD and the region with <10% RSD, respectively, and are found in the theoretical plot of the RSD of concentration estimates vs concentration.

17-alpha-Hydroxyprogesterone↗

Solving the "world-to-chip" interface problem with a microfluidic matrix.

We report an effective solution to the macroscopic/microfluidic interface issue and demonstrate how microfluidics can achieve impressive economies of scale in reducing the complexity of pipetting operations. Using an N x N microfluidic matrix with N = 20, we performed N2 = 400 distinct PCR reactions with only 2N + 1 = 41 pipetting steps, compared with the 3N2 = 1200 steps required with conventional fluid handling. Each vertex of the matrix has a 3-nL reactor, and a single 2-microL aliquot of polymerase is amortized over all 400 independent reactions, thus dramatically reducing sample overhead and minimizing reagent consumption. Beyond PCR, the matrix chip provides a general method to perform chemical and biological experiments with precious reagents in a highly automated fashion.

Journal Article↗

High-throughput comprehensive analysis of human plasma proteins: a step toward population proteomics.

A high-throughput (HT) comprehensive analysis approach was developed for assaying proteins directly from human plasma. Proteins were selectively retrieved, by utilizing antibodies immobilized within affinity pipet tips, and eluted onto enzymatically active mass spectrometer targets for subsequent digestion and structural characterization. Several parameters, including uniform parallel protein elution from 96 affinity pipet tips, proper buffering for on-target digestion, termination of the digestion, and MALDI matrix (re)introduction, were evaluated and optimized. The approach was validated via parallel, high-throughput analysis of transthyretin (TTR) and transferrin (TRFE) from 96 identical plasma samples. The 96 parallel analyses for each protein were completed in less than 90 min, measured from protein extraction to insertion in the mass spectrometer. Virtually identical mass spectra were obtained from the 96 TTR analyses, characterized by the presence of 14 tryptic fragments that allowed TTR sequence mapping with 100% coverage. Database search returned TTR as the best match for all 96 data sets. In regard to the TRFE analyses, database searching using data from the 96 spectra returned TRFE as the best match for all but 1 of the spectra. TRFE was mapped with 47-69% sequence coverage, with gaps in the sequence coverage corresponding to the carbohydrate-containing peptide fragments and large and small trypsin fragments that fell outside the window of mass analysis. Overall, the combined high-throughput affinity capture-protein digestion approach showed high reproducibility and speed and yielded an exceptional level of protein characterization, suggesting its use in future population proteomics endeavors.

Blood Proteins↗

Chronoamperometry at micropipet electrodes for determination of diffusion coefficients and transferred charges at liquid/liquid interfaces.

Chronoamperometry was carried out at liquid/liquid interfaces supported at the tip of micropipet electrodes for direct determination of the diffusion coefficient of a species in the outer solution. The diffusion coefficient was used for subsequent determination of the transferred charges per species from the diffusion-limited steady-state current. A large tip resistance of the micropipets causes prolonged charging current so that the faradic current can be measured accurately only at a long-time regime (typically t > 5 ms). At the same time, the long-time current response at the interfaces surrounded by a thin glass wall of the pipets is enhanced by diffusion of the species from behind the pipet tip. Therefore, numerical simulations of the long-time chronoamperometric response were carried out using the finite element method for accurate determination of diffusion coefficients. Validity of the simulation results was confirmed by studying simple transfer of tetraethylammonium ion. The technique was applied for transfer/adsorption reactions of the natural polypeptide protamine and also for Ca2+ and Mg2+ transfers facilitated by ionophore ETH 129. With the diffusion coefficient of protamine determined to be (1.2 +/- 0.1) x 10(-6) cm(2)/s, the ionic charge transferred by each protamine molecule was obtained as +20 +/- 1, which is close to the excess positive charge of protamine. Also, the diffusion coefficient of ETH 129 was determined to demonstrate that each ionophore molecule transfers +0.67 and +1 charge per Ca2+ and Mg2+ transfer, respectively, which corresponds to formation of 1:3 and 1:2 complexes with the respective ions.

Calcium↗

Voltammetric detection of heparin at polarized blood plasma/1,2-dichloroethane interfaces.

Heparin, a highly negatively charged polysaccharide, which has been used widely as an anticoagulant and antithrombotic, was detected by ion-transfer voltammetry at the interface between 1,2-dichloroethane and an aqueous buffer solution or undiluted blood plasma. Quaternary ammoniums with different numbers of methyl and long alkyl groups were examined as positively charged heparin ionophores using pipet electrodes filled with the organic electrolyte solutions of their tetrakis(4-chlorophenyl)borate salts. It was shown that octadecyltrimethylammonium most selectively facilitates interfacial heparin adsorption without interference from potential-dependent ionophore transfer into the aqueous phase. Water-filled pipet electrodes were also used to study the stoichiometry of the interfacial complex between a heparin molecule and multiple ionophore molecules, which is discussed as a counterion condensation effect. Stripping voltammetry based on facilitated heparin adsorption and desorption gives a detection limit of 0.012 unit/mL in 0.12 M NaCl buffered at pH 7.2, which is 1 order of magnitude lower than therapeutic heparin concentrations (>0.2 unit/mL) and is comparable to a detection limit of the most sensitive heparin sensor reported so far. The biomedical utility of ion-transfer voltammetry was demonstrated for the first time in an undiluted blood sample. Despite interferences by Na+, Cl-, and plasma proteins such as serum albumin, a detection limit of 0.13 unit/mL was obtained in sheep blood plasma with the stripping method.

Adsorption↗

Higher throughput bioanalysis by automation of a protein precipitation assay using a 96-well format with detection by LC-MS/MS.

Generic methodology for the automated preparation and analysis of drug levels in plasma samples within a drug discovery environment was achieved through the redesign of a protein precipitation assay to a microtiter (96-well) plate format and the application of robotic liquid handling for performance of all transfer and pipetting steps. Validation studies revealed that the application of robotics to sample preparation, in general, maintained the analytical accuracy and precision compared with preparing samples manually. The use of rapid gradient LC-MS/MS for analysis coupled with flow diversion of the solvent front allowed the introduction of protein-precipitated samples into the mass spectrometer without the necessity for source cleaning. The problem inherent in automatically pipetting plasma, caused by fibrinogen clots, was overcome by storing samples at -80 degrees C and thus precluding clot formation. The resulting methodology allowed sample preparation for a 96-well plate designed to accommodate 54 unknowns, duplicate 12-point calibration curves, and 6 sets of quality controls at three levels in approximately 2 h. This approach allowed an increase in throughput of sample preparation and analysis to >400 samples per day per LC-MS/MS instrument with minimal manual intervention. Overall, substantial time savings were realized, demonstrating that automation is an increasingly essential tool in a drug discovery bioanalytical environment.

Automation↗

Modeling of mixing in 96-well microplates observed with fluorescence indicators.

Mixing in 96-well microplates was studied using soluble pH indicators and a fluorescence pH sensor. Small amounts of alkali were added with the aid of a multichannel pipet, a piston pump, and a piezoelectric actuator. Mixing patterns were observed visually using a video camera. Addition of drops each of about 1 nL with the piezoelectric actuator resulted in umbrella and double-disklike shapes. Convective mixing was mainly observed in the upper part of the well, whereas the lower part was only mixed quickly when using the multichannel pipet and the piston pump with an addition volume of 5 microL or larger. Estimated mixing times were between a few seconds and several minutes. Mixing by liquid dispensing was much more effective than by shaking. A mixing model consisting of 21 elements could describe mixing dynamics observed by the dissolved fluorescence dye and by the optical immobilized pH sensor. This model can be applied for designing pH control in microplates or for design of kinetic experiments with liquid addition.

Acids↗

Combinatorial synthesis of oxide powders with an autopipetting system.

We describe development of a relatively simple, rapid route to produce combinatorial compositional oxide powder libraries by autopipetting of liquid precursors. This partitioning approach should apply equally well to any low viscosity, liquid precursors for the synthesis of oxide powders. A commercial autopipet is modified by fitting a plastic "mask" assembly beneath the pipet array in order to partition and direct liquids into crucibles. A series of 10 mixtures from two precursor solutions can be produced quickly. After they are dispensed, the liquid mixtures are dried in the crucibles and reacted at elevated temperatures to produce oxide powders. In the present work, the viability of the pipetting process is demonstrated by using a polymerizable complex powder synthesis method to produce (1-x) LaAlO(3) - x SrTiO(3) powders. For this system, a reaction at 900 degrees C for 2 h in air was sufficient to yield solid solutions in this system. X-ray powder diffraction was used to determine the pseudocubic unit cell lattice parameter. The linear change of lattice constant with composition confirms the compositional accuracy of the partitioning.

Journal Article↗