Reliability of conventional and new pulse oximetry in neonatal patients.

OBJECTIVES: Pulse oximetry is widely used in the NICU, but clinicians often distrust the displayed values during patient motion, i.e., questionable oxygen saturation (SpO(2)) and pulse rate (PR) values. Masimo Corporation (Irvine, CA) has developed pulse oximetry with claims of resistance to sources of interference. To test this premise, we compared the performance of the Masimo SET pulse oximeter to a conventional device, Nellcor N-200, and then with three other new-generation pulse oximeters, Nellcor N-395, Novametrix MARS, and Philips Viridia 24C. STUDY DESIGN: We studied 26 nonsedated NICU infants who were on supplemental oxygen and/or mechanical ventilation. ECG heart rate (HR) from a bedside monitor and SpO(2) and PR from the two pulse oximeters were captured by a PC for a total of 156 hours. The ECG HR and pulse oximeter spectral waveform were analyzed at alarms for hypoxemia (SpO(2)< or = 85%) and/or bradycardia (HR< or = 80 bpm). We then compared the performance of the Masimo SET to three other new-generation pulse oximeters, Agilent Viridia 24C, Nellcor N-395, and Novametrix MARS, in a similar population of seven infants for a total of 28 hours. We added to the test criteria the ability of the various pulse oximeters to track acute changes in HR. RESULTS: Compared with Nellcor, Masimo SET had 86% fewer false alarms, which also were shorter in duration, resulting in 92% less total alarm time. Masimo SET also identified nearly all bradycardias versus 14% for the Nellcor. Compared with the new-generation pulse oximeters, false desaturations, data drop-outs, and false bradycardias were lowest for Masimo SET, as was the capture of true desaturations and bradycardias. Notably, the new-generation devices differed greatly in their ability to detect changes in HR (i.e., the frequency of frozen PR during times of ECG HR change was 0, 6, 11, and 46 for Masimo, Nellcor, Philips, and Novametrix, respectively). CONCLUSIONS: Masimo SET pulse oximetry recorded markedly fewer false SpO(2) and PR alarms and identified more true hypoxic and bradycardic events than either conventional or other new-generation pulse oximeters. Masimo SET also most closely reflected the ECG rate irrespective of accelerations or decelerations in HR. SPECULATION: Routine use of Masimo SET pulse oximetry in the NICU could improve clinician confidence in the parameter leading to more judicious titration of oxygen with possible reductions in hypoxic (e.g., pulmonary hypertension) and hyperoxic (e.g., retinopathy of prematurity) pathology. Additionally, a more trustworthy technology should equate with fewer confirmatory arterial blood gas analyses (less blood loss), and faster weaning from the mechanical ventilation (less chronic lung disease).

Heart Rate↗

Prediction of sleep-disordered breathing by unattended overnight oximetry.

Between January 1994 and July 1997, 793 patients suspected of having sleep-disordered breathing had unattended overnight oximetry in their homes followed by laboratory polysomnography. From the oximetry data we extracted cumulative percentage time at SaO2 < 90% (CT90) and a saturation variability index (delta Index, the sum of the differences between successive readings divided by the number of readings - 1). CT90 was weakly correlated with polysomnographic apnea/hypopnea index (AHI). (Spearman rho = 0.36, P < 0.0001) and with delta Index (rho = 0.71, P < 0.0001). delta Index was more closely correlated with AHI (rho = 0.59, P < 0.0001). In a multivariate model, only delta Index was significantly related to AHI, the relationship being AHI = 18.8 delta Index + 7.7. The 95% CI for the coefficient were 16.2, 21.4, and for the constant were 5.8, 9.7. The sensitivity of a delta Index cut-off of 0.4 for the detection of AHI > or = 15 was 88%, for detection of AHI > or = 20 was 90% and for the detection of AHI > or = 25 was 91%. The specificity of delta Index > or = 0.4 for AHI > or = 15 was 40%. In 113 further patients, oximetry was performed simultaneously with laboratory polysomnography. Under these circumstances delta Index was more closely correlated with AHI (rho = 0.74, P < 0.0001), as was CT90 (rho = 0.58, P < 0.0001). Sensitivity of delta Index > or = 0.4 for detection of AHI > or = 15 was not improved at 88%, but specificity was better at 70%. We concluded that oximetry using a saturation variability index is sensitive but nonspecific for the detection of obstructive sleep apnea, and that few false negative but a significant proportion of false positive results arise from night-to-night variability.

Circadian Rhythm↗

Evaluation of accuracy of pulse oximetry in newborn calves.

In human medicine, pulse oximetry is widely used to measure non-invasively and accurately the percentage of oxygen saturation of arterial haemoglobin (SpO(2)). Recently, pulse oximetry has been used in calves, but its accuracy has not been evaluated in newborn calves. The purpose of this study was to evaluate the accuracy of a pulse oximeter in newborn calves by comparing SpO(2) with arterial oxyhaemoglobin saturation (SaO(2)) obtained by use of a blood gas analyser. Fifty-five newborn calves were investigated from birth to 20 days old. Pulse oximetry readings and arterial blood samples were performed 5, 15, 30, 45, 60 min, 2, 3, 6, 12, 24 h and 1 and 3 weeks after birth. The transmission-type sensors of the pulse oximeter were fixed at the recommended site in the bovine species (at the base of the calf tail, where the skin had been shaved and was not pigmented) and arterial blood samples were withdrawn from the subclavian artery and analysed for SaO(2). Five-hundred paired data of SaO(2) and mean SpO(2)(mSpO(2)) were collected. Linear regression of the pooled data indicated a highly significant correlation of mSpO(2) with SaO(2) (r = 0.87;P< 0.001; mSpO(2) = 15.8 + 0.84 SaO(2)). The overall data bias value was positive (+2.1%), which indicated that the pulse oximeter tended to overestimate the SaO(2). The bias value for each SaO(2) category tended to become higher for lower ranges of SaO(2). Precision was also lower when SaO(2) values were low. The lower the SaO(2) value, the higher the positive bias (overestimation) and the lower the precision. These results suggest that pulse oximetry provides a relatively accurate non-invasive, immediate and portable method to monitor SaO(2) and to evaluate objectively the pulmonary function effectiveness in newborn calves during their adaptation to extra-uterine life.

Aging↗

[Pulse oximetry screening for sleep-disordered breathing in stroke].

BACKGROUND: The prevalence of sleep-disordered breathing, particularly obstructive sleep apnea, among stroke patients is high. Routine screening with the current diagnostic gold standard of polysomnography is not feasible. Pulse oximetry could be a simple screening test. METHODS: The signal of pulse oximetry, recorded during full polysomnography in 184 stroke patients during neurological rehabilitation, was analyzed automatically by software for desaturations >/= 4 %. The polysomnographic apnoea-hypopnoea-index (AHI) was used as the diagnostic gold standard and compared with the oxygen desaturation index (ODI). RESULTS: Correlation between AHI of PSG and ODI of oximetry was r = 0.84 (p < 0.001). Dependent on the definition of SDB (AHI 10, 15, 20 or 30/h) and the cut-off-point for the ODI (e. g. 15/h) sensitivity was 32 - 83 % and specificity 99 - 96 %. The diagnostic accuracy as determined by the area under the ROC-curve was 96 %. CONCLUSION: Automated analysis of pulse oximetry gives reasonable results for screening for SDB in stroke patients and could be used in populations with high pre-test probability.

Female↗

Comparative analysis of arterial oxygen saturations during exercise by pulse oximetry, photometric measurements, and calculation procedures.

Pulse oximetry allows non-invasive monitoring of arterial oxygen saturation (SO2). To study the validity of pulse oximetry, comparative measurements were performed. During exhaustion limited exercise SO2-values measured by pulse oximetry (SO2puls), calculated SO2-values (algorithms of Kelman, Severinghaus, and Siggaard-Andersen--SO2calc), and as "golden standard" photometric measured SO2-values (SO2meas) were compared. Fourteen triathletes performed a stepwise cycling exercise test in the supine position. SO2calc was determined on the basis of capillary actual blood gas values. SO2puls was measured continuously with a finger probe attached to the second finger. The SO2puls- and SO2calc-values differed from the SO2meas-values (p less than 0.05); however, the differences were of no clinical relevance. Performing linear regression analysis, only SO2puls correlated significantly (r = 0.47, p less than 0.001) with SO2meas. Pulse oximetry is able to replace invasive measurements of arterial oxygen saturation in athletes. It is superior to SO2-calculations and permits reliable, valid and non-invasive continuous monitoring of SO2.

Adult↗

[Pulse oximetry and capnography in intensive care transportation: combined use reduces transportation risks].

OBJECTIVE: Due to the growing number of diagnostic and therapeutical procedures intensive-care patients must be transported intra- and interhospitally more often. These transports are among the most critical events during intensive-care therapy, with a high incidence of potentially life-threatening mishaps [23]. The aim of this study was to evaluate the possible benefit of the combined application of pulse oximetry and capnometry for patient safety during transport. METHODS: In a prospective clinical study 48 mechanically ventilated patients were allocated at random in 2 main study groups, 24 patients were investigated during interhospital transportation with an ambulance car, the other 24 patients during intrahospital transports. They were classified according to APACHE II and TISS. Blood pressure, heart rate and arterial blood gases were measured at eleven selected times. Twelve randomly chosen patients out of each main study group were monitored additionally with pulse oximetry and capnometry. The results were compared using the Mann-Whitney-U test. P < or = 0.05 was considered significant. RESULTS: Thirty-four patients had a TISS more than 40. The mean APACHE II-Score was 14 +/- 5. The overall incidence of potentially life-threatening mishaps was 9. Six out of these 9 occurred in the 24 patients with additional monitoring and were immediately detected by pulse oximetry or capnometry. CONCLUSIONS: The combination of pulse oximetry and capnometry offers the possibility to detect potentially life-threatening problems in ventilated patients during transport. This allows for early therapeutical consequences and may help to reduce the risk of transports.

APACHE↗

Automated graphic assessment of respiratory activity is superior to pulse oximetry and visual assessment for the detection of early respiratory depression during therapeutic upper endoscopy.

BACKGROUND: Recommendations from the American Society of Anesthesiologists suggest that monitoring for apnea using the detection of exhaled carbon dioxide (capnography) is a useful adjunct in the assessment of ventilatory status of patients undergoing sedation and analgesia. There are no data on the utility of capnography in GI endoscopy, nor is the frequency of abnormal ventilatory activity during endoscopy known. The aims of this study were to determine the following: (1) the frequency of abnormal ventilatory activity during therapeutic upper endoscopy, (2) the sensitivity of observation and pulse oximetry in the detection of apnea or disordered respiration, and (3) whether capnography provides an improvement over accepted monitoring techniques. METHODS: Forty-nine patients undergoing therapeutic upper endoscopy were monitored with standard methods including pulse oximetry, automated blood pressure measurement, and visual assessment. In addition, graphic assessment of respiratory activity with sidestream capnography was performed in all patients. Endoscopy personnel were blinded to capnography data. Episodes of apnea or disordered respiration detected by capnography were documented and compared with the occurrence of hypoxemia, hypercapnea, hypotension, and the recognition of abnormal respiratory activity by endoscopy personnel. RESULTS: Comparison of simultaneous respiratory rate measurements obtained by capnography and by auscultation with a pretracheal stethoscope verified that capnography was an excellent indicator of respiratory rate when compared with the reference standard (auscultation) (r = 0.967, p < 0.001). Fifty-four episodes of apnea or disordered respiration occurred in 28 patients (mean duration 70.8 seconds). Only 50% of apnea or disordered respiration episodes were eventually detected by pulse oximetry. None were detected by visual assessment (p < 0.0010). CONCLUSIONS: Apnea/disordered respiration occurs commonly during therapeutic upper endoscopy and frequently precedes the development of hypoxemia. Potentially important abnormalities in respiratory activity are undetected with pulse oximetry and visual assessment.

Adult↗

The use of pulse oximetry to detect congenital heart disease.

OBJECTIVE: To evaluate whether pulse oximetry can be used as a screening test to detect congenital heart disease (CHD) in otherwise well newborns before nursery discharge. METHODS: Births at Lakeland Regional Medical Center (LRMC) who met inclusion criteria, had a single pulse oximeter reading before discharge. A normal reading was considered to be >94%. Abnormal readings were repeated on a different extremity and if still abnormal, an echocardiography was performed. The number of children with CHD and the number of echocardiograms were compared with the previous year at LRMC. RESULTS: There were 2114 infants enrolled, 88 echocardiograms (3.8%) were performed, and 43 were abnormal (yield = 48.9%), of which 12 required management (13.6%). The control group consisted of 2851 births, producing 108 echocardiograms (3.8%), 42 of which were abnormal (38.9%), and 13 required management (12.0%). No comparisons were significant. During both years, 3 children with cyanotic CHD were born. Routine pulse oximetry failed to detect a child with total anomalous pulmonary venous return. Not a single normal echocardiogram was generated by the study. CONCLUSION: Routine pulse oximetry was nearly 100% specific for detecting cyanotic CHD; as a result there was no increase in the number of echocardiograms. Routine pulse oximetry did detect a child who might not have been detected otherwise but failed to detect one that should have been detected.

Cyanosis↗

Nonlinear characteristics of blood oxygen saturation from nocturnal oximetry for obstructive sleep apnoea detection.

Nocturnal oximetry is an attractive option for the diagnosis of obstructive sleep apnoea (OSA) syndrome because of its simplicity and low cost compared to polysomnography (PSG). The present study assesses nonlinear analysis of blood oxygen saturation (SaO(2)) from nocturnal oximetry as a diagnostic test to discriminate between OSA positive and OSA negative patients. A sample of 187 referred outpatients, clinically suspected of having OSA, was studied using nocturnal oximetry performed simultaneously with complete PSG. A positive OSA diagnosis was found for 111 cases, while the remaining 76 cases were classified as OSA negative. The following oximetric indices were obtained: cumulative time spent below a saturation of 90% (CT90), oxygen desaturation indices of 4% (ODI4), 3% (ODI3) and 2% (ODI2) and the delta index (Delta index). SaO(2) records were subsequently processed applying two nonlinear methods: central tendency measure (CTM) and Lempel-Ziv (LZ) complexity. Significant differences (p < 0.01) were found between OSA positive and OSA negative patients. Using CTM we obtained a sensitivity of 90.1% and a specificity of 82.9%, while with LZ the sensitivity was 86.5% and the specificity was 77.6%. CTM and LZ accuracies were higher than those provided by ODI4, ODI3, ODI2 and CT90. The results suggest that nonlinear analysis of SaO(2) signals from nocturnal oximetry could yield useful information in OSA diagnosis.

Adult↗

Usefulness of the oximetry test for the diagnosis of sleep apnea syndrome in Japan.

We evaluated the usefulness of oximetry tests that are frequently used as screening tools for sleep apnea syndrome (SAS) by determining the level of agreement between oximetry test results and polysomnography test (PSG) results. We retrospectively examined 135 patients suspected of having SAS. Although the oximetry desaturation index (DSI) seemed better than the oximetry apnea index in the agreement with the polysomnography respiratory disturbance index (RDI), the criteria of DSI greater than or equal to 15 was not sensitive enough to screen for moderate SAS (PSG-RDI >or= 20). Multivariate analyses revealing that body mass index (BMI) as well as DSI correlated well with PSG-RDI, we established a new criterion by adding the BMI score (DSI >or= 15 or BMI >or= 25), which remarkably improved the sensitivity. This criterion may be useful not only in clinical practice but also in medical checkups for asymptomatic patients, and also suggests that obese patients with sleep disturbance should undergo PSGs, irrespective of the DSI score.

Adult↗

A pilot study of left tracheal pulse oximetry.

We tested the hypothesis that left tracheal pulse oximetry (SpO(2)) is more accurate than finger SpO(2) when compared with oxygen saturation from arterial blood samples (SaO(2)) in anesthetized patients with normal thoracic anatomy. We also tested the hypothesis that tracheal oximetry readings are primarily derived from the tracheal mucosa. We studied 20 hemodynamically stable, well oxygenated, anesthetized patients with normal anatomy (ASA physical status I-III, 18-80 yr old). A single-use pediatric pulse oximeter was attached to the left lateral surface of a tracheal tube cuff. Tracheal and finger SpO(2) (dominant index finger), and SaO(2) (nondominant radial artery) were taken with the intracuff pressure at 0-60 cm H(2)O. Tracheal SpO(2) was the same as SaO(2) at an intracuff pressure of 10-60 cm H(2)O, but was less when the intracuff pressure was zero (P<0.0001). Tracheal SpO(2) was higher than finger SpO(2) at an intracuff pressure of 10-60 cm H(2)O (all: P <0.001), but was lower when the intracuff pressure was zero (P< 0.0001). SaO(2) was always higher than finger SaO(2) (P<0.0001). Tracheal SpO(2) was lower at an intracuff pressure of zero (P< 0.0001), but was otherwise similar over the range of intracuff pressures. SaO(2) and finger SpO(2) did not vary with intracuff pressure. Tracheal SpO(2) agrees more closely with SaO(2) than finger SpO(2) at an intracuff pressure of 10-60 cm H(2)O (mean difference < 0.2%). We conclude that left tracheal SpO(2) is feasible and provides similar readings to arterial blood samples and more accurate readings than finger oximetry in hemodynamically stable, well oxygenated, anesthetized patients with normal thoracic anatomy. Tracheal oximetry readings are not primarily derived from the tracheal mucosa. The technique merits further evaluation.

Adolescent↗

The feasibility of transesophageal echocardiograph-guided right and left ventricular oximetry in hemodynamically stable patients undergoing coronary artery bypass grafting.

UNLABELLED: There are no techniques available for continuous noninvasive measurement of the oxygen saturation of blood flowing through the heart. We assessed the feasibility and accuracy of transesophageal echocardiograph (TEE)-guided left ventricular (SpO2 LV) and right ventricular (SpO2 RV) oximetry. Twenty hemodynamically stable, well-oxygenated anesthetized patients (ASA physical status III, aged 51-75 yr) undergoing coronary artery bypass grafting were studied. A TEE probe was modified by attaching a single-use pediatric reflectance pulse oximeter just proximal to the ultrasound transducer. The TEE probe was directed toward the LV by using the transgastric mid-short axis view or toward the RV by using the transgastric RV inflow view, in random order. Readings were taken every 30 s for 10 min during a hemodynamically stable period of anesthesia. Simultaneous blood samples were taken from the radial artery and pulmonary artery to determine arterial oxygen saturation (SaO2) and mixed venous oxygen saturation (SvO2), respectively. During SpO2 LV readings, simultaneous finger pulse oximetry (SpO2 finger) was also recorded. SpO2 LV was feasible in 20 of 20 patients, and SpO2 RV was feasible in 19 of 20 patients. The mean +/- SD (range) oxygen saturation for each method was the following: SpO2 LV, 98.7% +/- 0.6% (97%-100%); SaO2, 98.7% +/- 0.6% (96.6%-99.4%); SpO2 finger, 98.1% +/- 1.2% (97%-100%); SpO2 RV, 73.9% +/- 4.7% (64%-85%); and SvO2, 74.5% +/- 4.4% (66.8%-82.6%). SpO2 LV agreed closely with SaO2 (mean difference, 0.072%). SpO2 RV agreed closely with SvO2 (mean difference, 0.65%). SpO2 LV agreed more closely with SaO2 than finger oximetry (mean difference, -0.072 vs -0.692). TEE-guided SpO2 LV and SpO2 RV are feasible in hemodynamically stable anesthetized patients and provide similar readings to arterial and mixed venous blood samples. The technique merits further investigation. IMPLICATIONS: Transesophageal echocardiograph-guided left and right ventricular oximetry is feasible in hemodynamically stable anesthetized patients and provides similar readings to arterial and mixed venous blood samples.

Aged↗

Continuous, noninvasive, and localized microvascular tissue oximetry using visible light spectroscopy.

BACKGROUND: The authors evaluated the ability of visible light spectroscopy (VLS) oximetry to detect hypoxemia and ischemia in human and animal subjects. Unlike near-infrared spectroscopy or pulse oximetry (SpO2), VLS tissue oximetry uses shallow-penetrating visible light to measure microvascular hemoglobin oxygen saturation (StO2) in small, thin tissue volumes. METHODS: In pigs, StO2 was measured in muscle and enteric mucosa during normoxia, hypoxemia (SpO2 = 40-96%), and ischemia (occlusion, arrest). In patients, StO2 was measured in skin, muscle, and oral/enteric mucosa during normoxia, hypoxemia (SpO2 = 60-99%), and ischemia (occlusion, compression, ventricular fibrillation). RESULTS: In pigs, normoxic StO2 was 71 +/- 4% (mean +/- SD), without differences between sites, and decreased during hypoxemia (muscle, 11 +/- 6%; P < 0.001) and ischemia (colon, 31 +/- 11%; P < 0.001). In patients, mean normoxic StO2 ranged from 68 to 77% at different sites (733 measures, 111 subjects); for each noninvasive site except skin, variance between subjects was low (e.g., colon, 69% +/- 4%, 40 subjects; buccal, 77% +/- 3%, 21 subjects). During hypoxemia, StO2 correlated with SpO2 (animals, r2 = 0.98; humans, r2 = 0.87). During ischemia, StO2 initially decreased at -1.3 +/- 0.2%/s and decreased to zero in 3-9 min (r2 = 0.94). Ischemia was distinguished from normoxia and hypoxemia by a widened pulse/VLS saturation difference (Delta < 30% during normoxia or hypoxemia vs. Delta > 35% during ischemia). CONCLUSIONS: VLS oximetry provides a continuous, noninvasive, and localized measurement of the StO2, sensitive to hypoxemia, regional, and global ischemia. The reproducible and narrow StO2 normal range for oral/enteric mucosa supports use of this site as an accessible and reliable reference point for the VLS monitoring of systemic flow.

Animals↗

Cerebral oxygenation monitoring by near-infrared spectroscopy is not clinically useful in patients with severe closed-head injury: a comparison with jugular venous bulb oximetry.

OBJECTIVE: To compare continuous jugular venous bulb oximetry and cerebral near-infrared spectroscopy in patients with severe closed head injury. DESIGN: A prospective observational study. SETTING: Intensive care unit of a major teaching hospital. PATIENTS: Adults (n = 10) with severe closed-head injury (Glasgow Coma Scale score of < or = 8). INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Jugular venous bulb oximetry, cerebral near-infrared spectroscopy, and cerebral perfusion pressure were measured continuously. A total of 3,691 paired measurements of near-infrared spectroscopy and jugular venous bulb oximetry were analyzed. Poor correlation (r2 = .04) between paired measurements and wide limits of agreement (-13% to +21%) were demonstrated. The mean difference between measurements was +/- 4% and the standard deviation of the mean difference was +/- 8.69%. The data were subsequently grouped according to three clinically significant subgroups of jugular venous bulb oxygen saturation reflecting low ( < 55%), normal (55% to 75%) and high ( > 75%) saturation values. Poor correlation and wide limits of agreement between the two methods of measurement were observed in all groups. Values recorded by near-infrared spectroscopy did not significantly change between the groups, and 14 clinically significant episodes of jugular venous bulb desaturation were not detected by near-infrared spectroscopy. CONCLUSIONS: Tissue oxygen saturation determined by near-infrared spectroscopy does not reflect significant changes in cerebral oxygenation detected by the global measurement of jugular venous bulb oximetry. This finding may be explained by inadequate signal detection and inaccuracies in the algorithm used to filter out extracranial components. Until these technical difficulties are addressed, near-infrared spectroscopy, as measured by the machine assessed in this study, cannot be routinely recommended for assessment of cerebral oxygenation in patients with acute head injury.

Adolescent↗

Increasing clinical use of pulse oximetry.

Changing the system from measuring blood gases through invasive measures to using noninvasive pulse oximetry is a challenge in the Critical Care Unit where invasive techniques are taken for granted. The authors report a project that was successful in increasing the use of noninvasive monitoring techniques by critical care nurses in a Surgical Intensive Care Unit. This clinical project became an important aspect of incorporating the staff in a change to more extensive use of pulse oximetry. This study defines the change in nursing practice with the use of pulse oximetry. The authors discuss three areas: (1) demonstration of the correlation between O2Sat as measured by the pulse oximeter and arterial blood gas saturations; (2) introduction of the pulse oximeter as a reliable alternative to ABGs when monitoring oxygenation; and (3) the establishment of guidelines for using pulse oximetry within the clinical setting.

Blood Gas Analysis↗

Knowledge of pulse oximetry among critical care nurses.

A pulse oximetry (SpO2) knowledge survey was conducted with 551 experienced critical care nurses at the 2002 American Association of Critical Care Nurses National Teaching Institute in Atlanta, GA. Results of this survey indicated an increased level of knowledge about SpO2 technology and monitoring compared to that reported in previous studies. These findings are important, because critical care nurses are responsible for providing care to the most critically ill patients. Critically ill patients are most likely to have decreases in their pulse oximetry values that require immediate interventions. In addition, critically ill patients are also the most likely group of patients to exhibit the clinical conditions that adversely affect pulse oximetry signal quality, including low perfusion and patient motion artifact. The ability of critical care nurses to correctly assess pulse oximetry values within the context of the technology limitations and the critical care environment is important in providing optimal care to critically ill patients.

Adult↗

Using pulse oximetry in the home.

As complex patients require more sophisticated nursing care and equipment to stay at home, home care nurses must be able to make detailed, objective assessments. Pulse oximetry provides a tool to objectively assess oxygenation in the home. This article reviews how pulse oximetry works, how to interpret the results based on the patient's blood oxygen-carrying capacity, and technical aspects of using pulse oximetry in the home, including sources of inaccuracy in measurements and basic troubleshooting. These pulse oximetry principles are applied in the home care setting in three case studies.

Adult↗

Intrapartum fetal pulse oximetry. Part I: Principles and technical issues.

UNLABELLED: Fetal pulse oximetry has been advocated as a means of improving the specificity of cardioto-cography in intrapartum fetal surveillance. The objective of this article, the first of two reviewing the current literature on fetal pulse oximetry, is to discuss the principles of this new and evolving technology, its development, and the various factors that can affect its readings during fetal monitoring. It serves as a prelude to the second article, which profiles the clinical application of fetal pulse oximetry. Literature pertaining to this topic was selected from a MEDLINE search from 1965 through September 1999, with additional sources obtained through cross-referencing. TARGET AUDIENCE: Obstetricians & Gynecologists, Family Physicians LEARNING OBJECTIVES: After completion of this article, the reader will be able to explain the principles of fetal pulse oximetry, and describe the factors that affect the calibration of fetal pulse oximeters and the factors that affect the fetal pulse oximeter readings.

Equipment Design↗