Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “MICROWAVES”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13Linked to original sources

Recovery of high-integrity mRNA from brains of rats killed by high-energy focused microwave irradiation.

Following decapitation, during the brief time period of postmortem brain tissue collection, significant changes in neuro-metabolite levels can occur. To circumvent such changes, we routinely kill rats using 1 to 2 sec pulses of focused high-energy microwave irradiation (10 kW). The effects of high-energy microwave irradiation on total RNA and mRNA integrity in brain however, are unknown. Total RNA recovery, per gram wet weight, in brain regions of microwaved rats was less than 50% of that in rats killed by decapitation. Formaldehyde agarose gel electrophoresis showed that ribosomal RNA components were highly degraded in all brain regions of microwaved rats. In contrast, poly A+mRNA, as measured by poly A+driven cDNA synthesis and Northern analysis, in brain samples of microwaved or decapitated rats was of equal integrity and quantity when expressed per mg tissue weight. Furthermore, positive RT-PCR products for GAPDH and TNF-alpha were observed in brain regions of both microwaved and decapitated rats. These observations indicated that high-energy focused microwave irradiation does not reduce mRNA abundance and integrity. Thus, this method of animal sacrifice can be used to simultaneously study, accurately and precisely, levels of brain metabolites as well as molecular biological events in discrete brain regions of experimental animals without postmortem interference.

Adenosine↗

Rapid parallel synthesis of polymer-bound enones utilizing microwave-assisted solid-phase chemistry.

A microwave-assisted parallel solid-phase synthesis of a collection of 21 polymer-bound enones has been developed. The two-step protocol involves initial high-speed acetoacetylation of polystyrene Wang resin with a selection of seven common beta-ketoesters. When microwave flash heating at 170 degreesC was employed, complete conversions were achieved within 1-10 min, a significant improvement over the conventional thermal method, which takes several hours for completion. Significant rate enhancements were also observed for the subsequent microwave-heated Knoevenagel condensations with a second set of 13 different aldehydes. Reaction times were reduced to 30-60 min at 125 degreesC in the microwave protocol compared to 1-2 days using conventional thermal conditions. Kinetic comparison studies indicate that the observed rate enhancements can be attributed to the rapid direct heating of the solvent (1,2-dichlorobenzene) by microwaves rather than to any specific microwave effect. All reactions have been carried out in commercially available parallel reactors with on-line temperature measurement, designed specifically for use in multimode microwave cavities.

Chemistry, Organic↗

Environmental remediation by an integrated microwave/UV illumination method. V. Thermal and nonthermal effects of microwave radiation on the photocatalyst and on the photodegradation of rhodamine-B under UV/Vis radiation.

The photocatalyzed degradation (PD) of the cationic rhodamine-B (RhB) dye was examined in aqueous TiO2 dispersions using UV/Vis illumination assisted by microwave radiation (PD/MW). The initial degradation by the PD/MW method is compared to the PD method and to the thermally assisted PD method using conventional heating (PD/TH). Total organic carbon (TOC) assays show that the efficiency of complete mineralization of the dye follows PD/MW > PD/TH > PD > MW. In all cases, microwave radiation alone had no effect on the loss of TOC. The degradation involving microwave radiation was especially efficient when coupled to UV irradiation. By contrast, the extent of degradation of RhB involving suitable excited states through visible irradiation of the dye was rather inefficient when coupled to microwave radiation. Contact angle measurements on the TiO2 photocatalyst particles indicate that microwave radiation also causes an increase in the hydrophobic character of the TiO2 surface, with consequences on the adsorption mode of the dye substrate and thus on the overall mechanism of degradation. Deethylated RhB intermediates were identified by an electrospray ESI ionization mass spectral technique in the positive ion mode and subsequently confirmed by HPLC/absorption spectroscopy. Computer simulations led to estimates of frontier electron densities of all atoms of the RhB structure, affording inferences as to the position of radical attack on RhB. The nitrogen atoms of the dye were all converted to NH4+ ions. The major difference between the thermally assisted PD/TH method and the microwave-assisted PD/MW method showed that nonthermal effects from the microwave radiation impact significantly on the nature of the photocatalyst surface. These effects led to a more efficient photodegradation and mineralization of the dye substrate.

Adsorption↗

Microwave-assisted headspace solid-phase microextraction for the analysis of bioemissions from Eucalyptus citriodora leaves.

Microwave-assisted headspace solid-phase microextraction (MA-HS-SPME) was developed as a simple and effective method for fast sampling of volatile organic compounds (VOCs) from Eucalyptus citriodora Hook (E. citriodora) leaves. During microwave heating, a simple shielding device made of aluminum foil was used to protect the SPME fiber from microwave irradiation while allowing the sample to be heated. A room temperature water bath was also used to allow microwave heating to be conducted in a more controlled manner. The inner heating caused by microwave irradiation dramatically accelerated the emission of VOCs from the sample, but no marked change in headspace temperature in the sample vial was found. Under optimum conditions, the extraction efficiencies obtained with microwave heating were much higher than those obtained without microwave heating for all fibers used, namely, 7-microm polydimethylsiloxane (PDMS), 100-microm polydimethylsiloxane (PDMS), 65-microm polydimethylsiloxane/divinylbenzene (PDMS/DVB), and 75-microm carboxen/polydimethylsiloxane (CAR/PDMS). The improvement of extraction efficiency using MA-HS-SPME allowed more VOC events to be detected, with more balanced extraction of VOCs of lower and higher molecular masses. Moreover, a good linear relationship was found between sample size and GC-FID response (total peak area of VOCs), indicating the usefulness of MA-HS-SPME for quantitative analysis of individual volatile compounds in E. citriodora leaves.

Chromatography, Gas↗

Evaluation of microwave irradiation for analysis of carbonyl sulfide, carbon disulfide, cyanogen, ethyl formate, methyl bromide, sulfuryl fluoride, propylene oxide, and phosphine in hay.

Fumigant residues in hay were "extracted" by microwave irradiation. Hay, in gastight glass flasks, was placed in a domestic microwave oven, and fumigants were released into the headspace by microwave irradiation. Power settings for maximum release of fumigants were determined for carbonyl sulfide (COS), carbon disulfide (CS(2)), cyanogen (C(2)N(2)), ethyl formate (EF), methyl bromide (CH(3)Br), sulfuryl fluoride (SF), propylene oxide (PPO), and phosphine (PH(3)). Recoveries of fortified samples were >91% for COS, CS(2), CH(3)Br, SF, PPO, and PH(3) and >76% for C(2)N(2) and EF. Completeness of extraction was assessed from the amount of fumigant retained by the microwaved hay. This amount was determined from further microwave irradiation and was always small (<5% of the amount obtained from the initial procedure). Limits of quantification were <0.1 mg/kg for COS, CS(2), C(2)N(2), EF, and PH(3) and <0.5 mg/kg for CH(3)Br, SF, and PPO. These low limits were essentially due to the absence of interference from solvents and no necessity to inject large-volume gas samples. The microwave method is rapid and solvent-free. However, care is required in selecting the appropriate power setting. The safety implications of heating sealed flasks in microwave ovens should be noted.

Animal Feed↗

Microwave cell death: Enzyme histochemical evaluation for metastatic carcinoma of the liver.

We have reported that microwave cell death is a unique cell death preserving not only cell and nuclear shapes but also immunohistochemical antigenicity. However, their enzyme activity was lost, which indicated cell dysfunction and death. This peculiar observation implies that the microwave effect is likely an 'in situ' tissue fixation and that this type of cell death is morphologically different from cell death, by either oncosis or apoptosis, as previously known. To confirm whether this peculiar cell death was observed also in human tissue samples, we examined clinical samples from patients with metastatic liver cancer, which were treated with microwave irradiation. They were examined immunohistochemically for human Ki-67 antigen and proliferating cell nuclear antigen and enzyme histochemically for alkaline phosphatase, and the same morphological changes that were observed in microwave-treated rat liver were found. In conclusion, we believe that routine hematoxylin-eosin stain alone is not a suitable method to evaluate microwave treatment for cancer because microwave coagulation therapy-treated cells preserved their nuclei and cellular architectures, even after 3 months. For microwave-treated tumors, enzyme histochemistry is helpful to determine its effectiveness.

Aged↗

Microwave ablation of the adrenal gland: experimental study and clinical application.

OBJECTIVE: To evaluate the heating effect of microwave irradiation on the dog adrenal gland and to assess the clinical feasibility of microwave ablation of adrenal tumours. MATERIALS AND METHODS: The thermal distribution and histology were evaluated after dog adrenal glands were irradiated at different intensities with microwaves. Irradiation at 70 W for 30 s was also performed after laparotomy, on the adrenal tumour of a patient with primary aldosteronism. RESULTS: Microwave irradiation at 70 W for 30 s provided a sufficiently high temperature to produce coagulation within a 5 mm radius of the microwave electrode. The adrenal tumor in the patient with primary aldosteronism was coagulated successfully by this dose of microwave irradiation. CONCLUSION: Microwave ablation of the adrenal gland may be clinically applicable in the treatment of adrenal tumours.

Adrenal Glands↗

Effect of microwave electromagnetic field on skeletal muscle fibre activity.

The aim of the present study was to investigate the influence of microwave irradiation on fatiguing activity of isolated frog skeletal muscle fibres. The changes in the electrical and mechanical activity were used as criteria for the exposure effects. Repetitive suprathreshold stimulation with interstimulus interval of 200 ms for 3 min was applied. Intracellular (ICAP) and extracellular (ECAP) action potentials and twitch contractions (Tw) of muscle fibres after 1 hour microwave exposure (2.45 GHz, 20 mW/cm( 2) power density) were compared with those recorded after one hour sham exposure (control). The duration of uninterrupted activity in the trial (endurance time; ET) was not significantly affected by microwave field exposure. After microwave irradiation, the ICAP amplitude was higher, the rising time was shorter, and the resting membrane potential was more negative compared to controls. There was a slower rate of parameters changes during ET in potentials obtained from irradiated fibres. Microwave exposure increased the propagation velocity of excitation, the ECAP and Tw amplitudes, as well as shortened their time parameters. We concluded that a 2.45 GHz microwave field possesses a stimulating effect on muscle fibre activity, which is in part due to its specific, non-thermal properties. The microwave induced-changes in muscle fibre activity may reduce development of skeletal muscle fatigue.

Action Potentials↗

Antigen retrieval by microwave oven heating for immunohistochemical analysis of bone marrow trephine biopsies.

Immunohistochemical analysis of bone marrow trephine (BMT) biopsies with monoclonal antibodies for the analysis of hemopoietic disorders has been hindered by the fixation and decalcification regimens which mask or destroy tissue antigens. This study evaluated the effect of microwave oven treatment on the quality of immunostaining of fixed decalcified trephine biopsies. The aim was to establish whether this method of pre-treatment would enable additional antigens to be detected. Fifty-eight monoclonal and 4 polyclonal antibodies to hemopoietic antigens were assessed to compare no tissue pre-treatment, proteolytic (trypsin) enzyme digestion and microwave oven heating. The microwave heating of the sections was performed by placing them in a boiling solution of 0.01M tri-sodium citrate for a total of 10 mins. Following microwave heating 14 antibodies that previously showed no reactivity in BMT biopsies gave positive staining and 9 antibodies previously known to detect antigens in the absence of pre-treatment gave enhanced staining. Other antibodies showed no staining improvement with microwave heating and some failed to give a positive reaction by any of the pre-treatment methods. Antigen retrieval utilizing microwave oven heating can expose antigenic sites for antibody binding in bone marrow trephine sections. However not all antigens are retrieved and there is variation between epitopes on the one molecule and their ability to be exposed by microwave heating. Utilizing antigen retrieval methods, the range of antibodies applicable to BMT sections is greatly expanded enabling the immunophenotypic analysis of the majority of hemopoietic disorders.

Antibodies, Monoclonal↗

Microwave enhanced recovery of nickel-copper ore: communition and floatability aspects.

A study describing the effect of microwave radiation, at a frequency of 2450 MHz, on the processes of communication and flotation of a complex sulphide nickel-copper ore is presented. Ore communication has been investigated under standard radiation-free conditions and after ore treatment in a radiated environment as a function of ore size, exposure time to radiation, and microwave power. The findings show that communication is tremendously improved by microwave radiation with values of the relative work index as low as 23% at a microwave power of 1.406 kW and after 10 s of exposure time. Communication is affected by exposure time and microwave power in a nontrivial manner. In terms of ore floatability, the experimental tests have been carried out on a sample of 75 microm in size under different exposure times. The results show that both ore concentrate recoveries and grades of nickel and copper are significantly enhanced after microwave treatment of the ore with relative increases in recovered concentrate, grade of nickel, and grade of copper of 26 wt%, 15 wt%, and 27%, respectively, at a microwave power of 1330 kW and after 30 s of exposure time.

Chemical Fractionation↗

Characterization of respiratory exposures at a microwave popcorn plant with cases of bronchiolitis obliterans.

Eight former workers from a microwave popcorn packaging plant were reported to have severe obstructive lung disease consistent with bronchiolitis obliterans. Investigations into respiratory exposures at this plant were done during August through November of 2000. Samples were collected to assess airborne particulate concentrations, particle size distributions, endotoxins, oxides of nitrogen, organic gases and vapors, and other analytes. Bulk corn and flavoring components were also analyzed for endotoxins and culturable bacteria and fungi. Workers in the microwave production areas of the plant were exposed to particulates and a range of organic vapors from flavorings. The particles were comprised largely of salt and oil/grease particles. Respirable dust concentrations (area plus personal) in the microwave mixer job category, the highest job exposure category in the plant, ranged from 0.13 milligrams per cubic meter of air (mg/m3) to a high of 0.77 mg/m3. Endotoxin concentrations were below 60 endotoxin units per cubic meter of air (EU/m3). Qualitative sampling for volatile organic compounds (VOCs) in the air detected over 100 different VOCs in the microwave area. The predominant compounds identified in the microwave mixing room included the ketones diacetyl, methyl ethyl ketone, acetoin, and 2-nonanone, and acetic acid. Diacetyl, the predominant ketone in the plant, was present in concentrations ranging from below detectable limits to 98 parts per million parts air by volume (ppm), with a mean of 8.1 ppm (standard deviation 18.5 ppm). The average ketone concentrations were highest in the microwave mixing room where the 10 area samples had a mean diacetyl concentration of 37.8 ppm (SD 27.6 ppm) and a mean acetoin concentration of 3.9 ppm (SD 4.3 ppm). These data show that workers involved in microwave popcorn packaging can be exposed to a complex mixture of VOCs from flavoring ingredients; animal studies show that diacetyl can cause airway epithelial injury, although the contributions of other specific compound(s) associated with obstructive respiratory disease in these workers is still unresolved.

Air Pollutants, Occupational↗

Influence of chopper and mixer speeds and microwave power level during the high-shear granulation process on the final granule characteristics.

Although microwave drying technology has been used extensively, detailed studies in the pharmaceutical field are necessary to model the different operational parameters involved in microwave drying in combination with the high-shear granulation processes. The implications of the chopper and the mixer speeds during the granulation step and the microwave power level during the drying step on the final granule characteristics were investigated. alpha-Lactose monohydrate and microcrystalline cellulose were granulated at three different mixer and chopper speeds in a laboratory-scale high-shear mixer (Mi-Mi-Pro) and dried at three microwave power levels. The dried granules were characterized by friability tests, particle size analysis, bulk and tapped density studies, and porosimetry. Neither the mixer speed nor the chopper speed had a significant influence on the granule friability, which was low for all batches produced. The selected materials and experimental conditions induced a very robust granulation process, but the granule size distribution was influenced by the microwave power level. The reciprocal relationship between the dust formation and the microwave power level was analyzed using a central composite factorial design. The amount of dust remained low in all batches, but it influenced some of the inherent density properties and the volume reduction behavior of the granulation mass. In almost all cases, the Carr index decreased slightly with increasing microwave power. The major granule characteristics were not changed when different mixer or chopper speeds were changed, although the mixer speed did alter the intragranular pore size distribution.

Lactose↗

Transurethral microwave thermotherapy: an alternative to medical management in patients with benign prostatic hyperplasia?

Transurethral microwave thermotherapy (TUMT) is being increasingly considered as an alternative to medical management with alpha-blockers or finasteride in patients with lower urinary tract symptoms (LUTS) of benign prostate hyperplasia (BPH). Enduring clinical benefits have been demonstrated after a single 1-hour microwave treatment session under topical anesthesia, and the associated morbidity is low. Optimal results are obtained with the delivery of high thermal doses and accurate targeting of microwave energy. Extensive evidence from randomized clinical trials supports the safety and efficacy of both microwave treatment and medical management, but randomized trial data have only recently become available directly comparing these two approaches to BPH treatment. These data indicate that greater long-term improvements in symptoms, peak urinary flow rates, and quality of life are attained with microwave treatment than with alpha-blockade. Furthermore, the actuarial rate of treatment failure is markedly lower in patients undergoing microwave v alpha-blocker treatment. However, the onset of action of alpha-blocker treatment is more rapid. The principal limitations of alpha-blockade are side effects and lack of efficacy leading to treatment failure in some patients. The maximal effects of finasteride are modest and require a period of months to be manifested, although the side effect profile and tolerability of this agent are favorable. Neoadjuvant and adjuvant alpha-blocker therapy can accelerate symptom and flow rate improvement after TUMT. In contrast to medical management, microwave treatment is highly versatile, allowing patients over a broad range of baseline symptom severities and prostate sizes to be treated with a high probability of success.

Adrenergic alpha-Antagonists↗

Third Prize: Comparison of radical nephrectomy, laparoscopic microwave thermotherapy, cryotherapy, and radiofrequency ablation for destruction of experimental VX-2 renal tumors in rabbits.

BACKGROUND AND PURPOSE: Currently available minimally invasive renal tumor-ablation procedures include cryotherapy, radiofrequency ablation, and microwave thermotherapy. In this study, we investigated the ability of these three approaches to destroy experimental renal tumors in rabbits. The mechanism of potential tumor metastasis was also explored. MATERIALS AND METHODS: The VX-2 tumor line is an aggressive rabbit epidermoid tumor with a high metastatic potential. An initial experiment comparing cooled-tip microwave thermotherapy with cryotherapy and radical nephrectomy for treatment of small VX-2 tumors revealed that all microwave-treated rabbits had local recurrence and that several also had diffuse intraperitoneal carcinomatosis. In view of these results, a second experiment was performed in which 45 New Zealand White rabbits were implanted laparoscopically with VX-2 xenografts underneath the kidney capsule and divided into five groups of 9 each. The test groups were microwave thermotherapy with a 3.5-mm cooled-tip probe, microwave thermotherapy with a 3.5-mm noncooled- tip probe, radiofrequency ablation with a 1.5-mm cooled-tip probe, radiofrequency ablation with a 1.5- mm non-cooled tip probe, and cryotherapy with a 2.3-mm cryoprobe. The control groups were five rabbits that were not treated, five rabbits with tumors that had the tumor pierced with a probe but were untreated, and five rabbits that underwent nephrectomy after piercing of the tumor. Treatment was initiated 5 days after tumor implantation. One month later, all animals were euthanized and autopsied. RESULTS: At 5 days after tumor implantation, laparoscopic inspection revealed no visible peritoneal metastases. At 1 month, in the cooled and non-cooled microwave-thermotherapy groups, carcinomatosis occurred in five and six of nine animals, respectively. In comparison, carcinomatosis was detected in two of nine animals in the cryotherapy group at autopsy. With respect to cooled and non-cooled radiofrequency ablation, carcinomatosis was observed in four of nine rabbits in each group. In the control groups, none of the animals with unpierced tumors exhibited carcinomatosis, while carcinomatosis was seen in two of the five rabbits with tumor violated by piercing and in three of the five rabbits that underwent immediate nephrectomy after piercing of the tumor. CONCLUSION: Carcinomatosis occurred most frequently in animals treated with microwave thermotherapy, followed by radiofrequency ablation, and lastly cryoablation. The simple act of piercing a highly aggressive tumor can result in local spread. More disconcerting, and less well understood, is why certain ablative modalities appear to increase the rate of intraperitoneal spread.

Animals↗

Microwave irradiation and soft contact lens parameters.

We evaluated the effect of repeated microwave irradiation on soft contact lens parameters to determine if microwave disinfection affects soft lens polymers or parameters. Ten factory-sealed lenses from each of the four FDA categories were placed in Ciba AOsept cases which were filled with 13 ml of sterile unpreserved saline. The cases were placed in a 10-cm diameter circle on the rotating plate of a standard 2450 MHz 650 W microwave oven and exposed to repeated 5-min cycles of microwave irradiation. The lens parameters, including back vertex power, back optic zone radius, diameter, thickness and water content, were measured over a period of 200 cycles to simulate over 6 months of daily disinfection. The postirradiation measurements were compared to baseline measurements taken before microwave exposure. We found statistically significant changes in many lens parameters, but all were small and few were clinically significant. These findings indicate that microwave disinfection does not have a clinically significant effect on the parameters of most unworn soft contact lenses. Further studies are needed to determine the long-term effects of microwave disinfection on worn soft contact lenses.

Contact Lenses, Hydrophilic↗

Microwave drilling of bones.

This paper presents a feasibility study of drilling in fresh wet bone tissue in vitro using the microwave drill method [Jerby et al, 2002], toward testing its applicability in orthopaedic surgery. The microwave drill uses a near-field focused energy (typically, power under approximately 200 W at 2.45-GHz frequency) in order to penetrate bone in a drilling speed of approximately 1 mm/s. The effect of microwave drilling on mechanical properties of whole ovine tibial and chicken femoral bones drilled in vitro was studied using three-point-bending strength and fatigue tests. Properties were compared to those of geometrically similar bones that were equivalently drilled using the currently accepted mechanical rotary drilling method. Strength of mid-shaft, elastic moduli, and cycles to failure in fatigue were statistically indistinguishable between specimen groups assigned for microwave and mechanical drilling. Carbonized margins around the microwave-drilled hole were approximately 15% the hole diameter. Optical and scanning electron microscopy studies showed that the microwave drill produces substantially smoother holes in cortical bone than those produced by a mechanical drill. The hot spot produced by the microwave drill has the potential for overcoming two major problems presently associated with mechanical drilling in cortical and trabecular bone during orthopaedic surgeries: formation of debris and rupture of bone vasculature during drilling.

Animals↗

Inactivation of Lactobacillus bacteriophage PL-1 by microwave irradiation.

The effect of microwave irradiation on the survival of bacteriophage PL-1, which is specific for Lactobacillus casei, was studied using a commercial 2,450 MHz microwave oven. The phages were inactivated by microwave irradiation according to almost first-order reaction kinetics. The rate of phage inactivation was not affected by the difference in the continuous or intermittent irradiation, nor by the concentrations of phages used, but was affected by the volume of phage suspensions, which prevented the loss of generated heat. Microwave irradiation of phage suspensions produced a number of ghost phages with empty heads, but fragmentation of the tail was hardly noticed. The breakage of phage genome DNA was primarily caused by the heat generated by microwave irradiation, whereas the phage DNA was not affected by the same temperature achieved by heat from outside. Thus we concluded that the phage-inactivating effect of microwave irradiation was mainly attributed to a thermal microwave effect, which was much stronger than a simple thermal exposure.

Bacteriophages↗

Prospective comparison of temperature guided microwave and radiofrequency catheter ablation in the swine heart.

Microwave energy has been proposed as an alternative to radiofrequency energy for use during catheter ablation procedures. The purpose of this study was to prospectively compare, in an animal model, the lesion size associated with temperature guided catheter ablation using either microwave or radiofrequency energy. Eleven swine underwent catheter ablation with either radiofrequency (N = 4) or microwave energy (N = 7). In each animal catheter ablation was performed at 7-15 sites. At each site energy was delivered for 60 seconds using closed loop feedback temperature control to achieve a target temperature of 70 degrees C. Cardiac catheterization was performed before and after ablation. Animals were sacrificed approximately one month following the ablation procedure. Analysis of lesion size demonstrated that overall lesions created using radiofrequency energy were larger than those created using microwave energy. In the ventricle, lesions created using microwave energy were longer, but had a similar width and depth as those created using radiofrequency energy. An important relation was observed between the depth of lesions created using microwave energy and catheter stability, as evidenced by the temperature profile. Overall, lesions created using microwave energy are smaller than those created using radiofrequency energy. Catheter stability has an important impact on lesion size.

Animals↗