Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Lasers”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13Linked to original sources

Combined technique of argon-laser and neodymium-YAG laser photocoagulation for narrow-or closed-angle glaucoma.

A combined laser technique was applied in 76 eyes with narrow- or closed-angle glaucoma. In the first act circular Argon-laser iridoplasty was performed, to be followed by peripheral Nd-YAG laser iridotomy. Before the laser application, intraocular pressure was decreased using medicamentous antiglaucoma therapy to 30 mmHg or less. Argon-laser iridoplasty was performed in the peripheral third of the total iris circumference applying cca 20 laser spots. Eight days later, Nd-YAG laser iridotomy was performed at the site of the previous Argon-laser spot. Postoperative intraocular pressure was normal in 64 out of 76 eyes (84.2%) on the last check-up, and the additional antiglaucoma medications was significantly reduced. In a small number of cases i.e. 24 eyes (31.6%), the medical therapy was altogether cancelled. In 12 eyes (15.8%) the laser treatment has failed, and antiglaucoma surgery had to be performed subsequently. The observation period ranged from 4 to 25 months.

Adult↗

Effects of laser irradiation on human erythrocytes: considerations concerning clinical laser angioplasty.

Recent studies demonstrate the potential use of laser to vaporize human coronary atherosclerotic plaques. The laser energy is transmitted through flexible quartz fiber and discharged intravascularly. Since red blood cells could be exposed to intense heat, we examined effects of laser irradiation on human erythrocytes. Blood was obtained and placed in 5 ethylene diaminetetracidic acid (EDTA) vials for each normal donor. A flexible 400 microns diameter core quartz fiber coupled to an argon-ion laser source was positioned 1 cm above the surface of 1.5 ml blood. Four vials were exposed to 5 W laser beam for 5, 10, 15, or 20 s; the remaining vial was left untreated. Packed cell volume fell primarily during the first 5 s of laser exposure (p less than 0.01) and plateaued beyond 5 s. Plasma hemoglobin (Hgb) rose progressively with each increased duration of exposure (p less than 0.01). This study indicates that lysis of erythrocytes occurs in cells exposed directly to the laser beam. However, beyond the direct beam, damage to red cell membrane took place as evident by progressive Hgb leakage into plasma despite no further cell lysis. These observations require consideration during clinical laser angioplasty.

Erythrocyte Indices↗

Laser pulse impact on rat mesenteric blood vessels in relation to laser treatment of port wine stain.

BACKGROUND AND OBJECTIVE: To study the impact of laser pulses on animal microvasculature as a model for laser treatment of port wine stains. STUDY DESIGN/MATERIALS AND METHODS: Rat mesenteric blood vessels were irradiated with a laser pulse (585 nm, 0.2-0.6 ms pulse duration, 0.5-30 J/cm(2) radiant exposure). Video microscopy was used to assess vessel dilation, formation of intravascular thrombi, bubble formation, and vessel rupture. Changes in reflection during a laser pulse were measured by simultaneously recording the temporal behavior of the incident and reflected signals. RESULTS: A threshold radiant exposure of approximately 3 J/cm(2) was found for changes in optical properties of blood in vivo, confirming previous in vitro results. Often, laser exposure induced a significant increase in vessel diameter, up to three times the initial diameter for venules and four times for arterioles, within 200 ms after laser exposure. Arterioles were more likely to dilate than venules. Sometimes, immediately after the pulse, round structures, interpreted as being gas bubbles, were seen within the vessel lumen. CONCLUSIONS: A variety of phenomena can occur when blood vessels of sizes comparable to those in port wine stains are irradiated with laser pulses as used in port wine stain treatment. Thrombus formation and vessel rupture have been described before from histological sections of laser-irradiated port wine stains. However, vessel dilation and formation of non-transient gas bubbles as found in this study have not been described before.

Animals↗

Arthroscopic shoulder surgery with three different laser systems: an evaluation of laser applications.

Twelve cadaveric shoulder arthroscopies were performed to evaluate the use of lasers as an adjunctive tool in arthroscopic shoulder surgery. The three most common lasers historically used in orthopedic surgery were examined: Holmium:YAG, Neodymium:YAG, and the CO2. The following parameters were evaluated for each laser system: (1) ease of use of the laser system and handpiece; (2) ability to excise and trim bursae, synovium, ligament, tendon, bone, and articular cartilage; and (3) ability to contract ligaments and capsule by heat transfer. None of these lasers efficiently cut bone, whereas all three systems readily debrided the soft tissues around the shoulder. The free-beam Ho:YAG and CO2 systems heat contracted soft tissues with more control than the contact Nd:YAG. The fiberoptic delivery system of the Neodymium:YAG and Holmium:YAG laser performed well in the saline arthroscopy, and the CO2 delivery system was cumbersome. Overall, the CO2 system removed tissue better than the others, but its difficult use favored the Holmium laser as the best overall current laser system for shoulder arthroscopy.

Aluminum Silicates↗

Scanning laser ophthalmoscope fundus perimetry before and after laser photocoagulation for clinically significant diabetic macular edema.

PURPOSE: To prospectively evaluate functional and funduscopic changes after laser treatment in patients with diabetic retinopathy and clinically significant macular edema by scanning laser ophthalmoscope fundus perimetry. METHODS: Thirty eyes of 30 patients with clinically significant macular edema as a result of diabetic retinopathy were prospectively examined before and at least 3 months after focal laser treatment with automatic fundus threshold perimetry using the scanning laser ophthalmoscope. Thresholds of light sensitivity were compared with age-corrected normal values and correlated with corrected visual acuity and subjective appraisal of visual function. RESULTS: In 30 eyes, fundus perimetry lasted for 10.5+/-2.7 (mean+/-SD) minutes with 322+/-67 stimulus presentations for each eye. Whereas eight eyes remained stable (< +/-1 dB change), 15 improved concerning mean deviation (MD) (3.1+/-1.7 dB) after focal laser treatment. Stability of fixation remained the same after focal laser treatment (0.75+/-0.57 degree). Laser scars showed marked loss of function (MD > 13 dB). CONCLUSIONS: Although light sensitivity was reduced in areas of macular edema, there was no correlation between the amount of edema and visual function. Fundus perimetry allows the creation of exact maps of retinal dysfunction before and after laser treatment. It may help in making management decisions in diabetic and nondiabetic patients by offering a sensitive parameter in addition to visual acuity.

Adult↗

Comparison of laser phacovaporization using the Er-YAG and the Er-YSGG laser.

OBJECTIVE: To study the interaction of the erbium (Er)-YAG (2.94 microns) and the Er-YSGG (2.79 microns) lasers with the human crystalline lens tissue. METHODS: Fresh human crystalline lens sections were used to measure the photovaporization threshold, rate, and damage zone of the two lasers. RESULTS: We found the photovaporization threshold for the Er-YAG and the Er-YSGG lasers to be 1.4 J/cm2 and 5.5 J/cm2, respectively. At 10 J/cm2, the photovaporization rate is 67.9 microns per pulse for the Er-YAG laser and 18.4 microns per pulse for the Er-YSGG laser. The increased rate of photovaporization as a function of radiant energy for the Er-YAG laser is almost twice that for the Er-YSGG. Damage zones for the Er-YAG laser ranged from 4 to 9 microns compared with 10 to 22 microns for the Er-YSGG. CONCLUSIONS: It is apparent that both lasers can adequately photovaporize human crystalline lens tissue and should be further studied for this purpose.

Cataract Extraction↗

Collagen tightening induced by carbon dioxide laser versus erbium: YAG laser.

BACKGROUND AND OBJECTIVE: Pulsed CO2 laser resurfacing improves photodamage and acne scarring by ablation of abnormal tissue with subsequent regeneration and remodeling of collagen and through heat induced collagen contraction. Whether collagen contraction persists long-term and helps maintain the skin tightening observed after resurfacing is debated. One possible mechanism of long-term clinical tightening is that of wound contracture that occurs as part of normal wound healing. If normal wound contracture, and not heat induced collagen contraction, is responsible for maintaining the initial skin tightening seen in CO2 laser resurfacing, then equal results would be expected from resurfacing with either CO2 or erbium lasers. The study was performed to determine whether there is a difference in skin tightening secondary to thermally mediated collagen contraction versus that which occurs secondary to tissue contraction of wound healing. The persistence of these changes over 6 months and the histologic characteristics were studied as well. STUDY DESIGN/MATERIALS AND METHODS: Nine patients had four tattoo dots applied to the upper eyelids, with horizontal axis measuring 18-20 mm and the vertical axis 6-10 mm. One month later, one eyelid was treated with three passes of the UltraPulse CO2 laser and the other eyelid with an erbium laser to the end point of early pinpoint bleeding. Three patients were treated with additional passes after pinpoint bleeding was encountered. The total number of pulses used per patient was recorded. Measurements of the vertical and horizontal distances were made after each pass and monthly for 6 months. The treated skin was then excised in performance of an upper lid blepharoplasty and the tissue submitted for histologic analysis. RESULTS: In the vertical plane, the UltraPulse CO2 laser induced an average of 43% tightening intraoperatively and this gradually diminished to an average of 34% by 6 months, whereas the wound contracture of erbium resurfacing was not seen until 1 month postoperatively, at which time 42% tightening was seen, gradually diminishing to 36% at 6 months. Three patients with erbium resurfacing had scarring present. These were the three patients treated most aggressively and also the three patients with the most significant wound contracture. Scarring was not seen on the CO2 treated side in any patients. In the horizontal plane, the CO2 laser caused 31% intraoperative tightening, decreasing to 19% at 6 months. In this plane, the erbium laser induced wound contracture was 12% at 1 month which remained stable and unchanged. CONCLUSIONS: Although wound contraction secondary to tissue healing may result in nearly the same tissue tightening as heat-induced collagen contraction, the two processes are very different and variable, with increased risk of scarring seen with wound contracture, compared with heat-induced collagen tightening. The tissue tightening seen with thermally induced collagen contraction is long-lasting, if not "permanent."

Blepharoplasty↗

Laser induced cell fusion in combination with optical tweezers: the laser cell fusion trap.

A single-beam gradient force optical trap was combined with a pulsed UV laser microbeam in order to perform laser induced cell fusion. This combination offers the possibility to selectively fuse two single cells without critical chemical or electrical treatment. The optical trap was created by directing a Nd:YAG laser, at a wavelength of 1.06 microns, into a microscope and focusing the laser beam with a high numerical aperture objective. The UV laser microbeam, produced by a nitrogen-pumped dye laser (366 nm), was collinear with the trapping beam. Once inside the trap, two cells could be fused with several pulses of the UV laser microbeam, attenuated to an energy of approximately 1 microJ/pulse in the object plane. This method of laser induced cell fusion should provide increased selectivity and efficiency in generating viable hybrid cells.

Animals↗

Cryogen spray cooling efficiency: improvement of port wine stain laser therapy through multiple-intermittent cryogen spurts and laser pulses.

BACKGROUND AND OBJECTIVES: Cryogen spray cooling (CSC) is used to minimize the risk of epidermal damage during laser treatment of port wine stain (PWS) birthmarks. Unfortunately, CSC may not provide the necessary protection for patients with high concentrations of epidermal melanin. The objectives of this study are to: (1) provide a definition of cooling efficiency (eta) based on the amount of heat removed per unit area of skin for a given cooling time; (2) using this definition, establish the eta of previously reported spray nozzles; (3) identify the maximum benefit expected in PWS laser therapy based solely on improvement of eta; and (4) study the feasibility of using multiple-intermittent cryogen spurts and laser pulses to improve PWS laser therapy. STUDY DESIGN/MATERIALS AND METHODS: A theoretical definition to quantify eta is introduced. Subsequently, finite difference heat diffusion and Monte Carlo light distribution models are used to study the spatial and temporal temperature distributions in PWS skin considering: (1) the current approach to PWS laser therapy consisting of a single cryogen spurt followed by a single pulsed dye laser exposure (SCS-SLP approach); and (2) multiple cryogen spurts and laser pulses (MCS-MLP approach). At the same time, an Arrhenius-type kinetic model is used to compute the epidermal and PWS thermal damages (Omega(E) and Omega(PWS), respectively) for a high epidermal melanin concentration (20%), corresponding to skin types V-VI. RESULTS: The eta corresponding to a wide range of heat transfer coefficients (h) is quantified. For reported CSC nozzle devices eta varies from 40 to 98%. Using the SCS-SLP approach, it is shown that even eta = 100% cannot prevent excessive Omega(E) for a skin types V-VI. In contrast, the MCS-MLP approach provides adequate epidermal protection while permitting PWS photocoagulation for the same skin types. CONCLUSIONS: The new proposed definition allows to compute the cooling efficiency of CSC nozzle devices. Computer models have been developed and used to show that the SCS-SLP approach will not provide adequate epidermal protection for darker skin patients (skin types V-VI), even for eta = 100%. In contrast, the MCS-MLP approach may be a viable solution to improve PWS laser therapy for darker skin patients.

Burns↗

Use of a new ICG-dye-enhanced diode laser for percutaneous laser disc decompression.

BACKGROUND AND OBJECTIVE: The lasers used today for Percutaneous Laser Disc Decompression (PLDD) can not selectively ablate the nucleus pulposus (NP). We hypothesized that if indocyanine green dye were injected into the NP, 805 nm diode laser irradiation would result in selective and safe removal of NP tissue without damaging nearby tissues. STUDY DESIGN/MATERIALS AND METHODS: Twelve beagle dogs were used for three experiments, i.e., determination of attenuation coefficients of NP and AF, determination of weight of NP before and after laser irradiation, and histopathological study. RESULTS: The attenuation coefficient at 805 nm of NP which had been homogenized in the presence of ICG was 2521.3/cm. Upon application of the diode laser at a power of 1, 3, or 5 W (the intensity of laser irradiation: 0.353, 1.061, or 1.768 x 10(3) W/cm(2)) to NPs into which ICG had been injected, the weight of the NPs decreased by a mean 20, 45, and 65%, respectively. Macroscopic and microscopic examination of the discs after PLDD showed that only the NP where the tissues were stained by ICG were removed. CONCLUSIONS: These results indicated that the combined use of ICG and diode laser irradiation effectively and selectively ablates the NP with low laser power.

Animals↗

Vasovasostomy in the murine vas deferens: comparison of the Nd:YAG laser at 1.06 microns and 1.318 microns to the CO2 laser.

A comparison is made of laser anastomoses of the murine vas deferens at different energies with the neodymium (Nd):YAG laser at 1.06 micron and 1.318 micron and with the CO2 laser. A total of 28 welds were performed with a free-hand technique employing a 600-micron silicon fiber with the Nd:YAG and a hand piece with a 500-micron spot size for the CO2. After 6 weeks, all animals were sacrificed and the vasa evaluated for patency. Fifteen out of 28 controls repaired with microsurgical techniques were found to be patent; 4/10 vasa were patent with use of the Nd:YAG at 1.318 micron at laser energies of 300 mW and 500 mW. At 1.06 micron, only 1/4 anastomoses was patent at a power setting of 1 W. None of the anastomoses performed with the CO2 laser was patent. Histologic study revealed intense fibrosis in all the lasered vasa, with sperm granuloma formation associated with most anastomoses. Although this is a preliminary study, it appears that the Nd:YAG laser at 1.318 micron and a power setting of 300-500 mW provides patency rates superior to the Nd:YAG at 1.06 micron and to the CO2 lasers and is equivalent to standard micro-surgical techniques in the murine vas deferens.

Animals↗

Therapeutic ratio quantifies laser antisepsis: ablation of Porphyromonas gingivalis with dental lasers.

BACKGROUND AND OBJECTIVES: It is established that both pulsed Nd:YAG (1,064 nm) and continuous diode (810 nm) dental lasers kill pathogenic bacteria (laser antisepsis), but a quantitative method for determining clinical dosimetry does not exist. The purpose of this study was to develop a method to quantify the efficacy of ablation of Porphyromonas gingivalis (Pg) in vitro for two different lasers. STUDY DESIGN/MATERIALS AND METHODS: The ablation thresholds for the two lasers were compared in the following manner. The energy density was measured as a function of distance from the output of the fiber-optic delivery system. Pg cultures were grown on blood agar plates under standard anaerobic conditions. Blood agar provides an approximation of gingival tissue for the wavelengths tested in having hemoglobin as a primary absorber. Single pulses of laser energy were delivered to Pg colonies and the energy density was increased until the appearance of a small plume was observed coincident with a laser pulse. The energy density at this point defines the ablation threshold. Ablation thresholds to a single pulse were determined for both Pg and for blood agar alone. RESULTS: The large difference in ablation thresholds between the pigmented pathogen and the host matrix for pulsed-Nd:YAG represented a significant therapeutic ratio and Pg was ablated without visible effect on the blood agar. Near threshold the 810-nm diode laser destroyed both the pathogen and the gel. CONCLUSIONS: Clinically, the pulsed Nd:YAG may selectively destroy pigmented pathogens leaving the surrounding tissue intact. The 810-nm diode laser may not demonstrate this selectivity due to its greater absorption by hemoglobin and/or longer pulse duration.

Antisepsis↗

Treatment of inflammatory facial acne vulgaris with combination 595-nm pulsed-dye laser with dynamic-cooling-device and 1,450-nm diode laser.

BACKGROUND AND OBJECTIVES: The 585-nm pulsed-dye laser and the 1,450-nm diode laser have been found effective for the treatment of mild-to-moderate inflammatory facial acne. This study was designed to evaluate the efficacy and safety of the combined treatment with the 595-nm pulsed-dye laser and the 1,450-nm diode laser for inflammatory facial acne. STUDY DESIGN/MATERIALS AND METHODS: Fifteen patients with inflammatory facial acne were treated with a combination of the 595-nm pulsed-dye laser and the 1,450-nm diode laser. Patients' subjective response to treatment was evaluated regarding improvement in acne, acne scarring, oiliness, and redness of the skin. RESULTS: All patients had reductions in acne lesion counts. Mean lesion counts decreased 52% (P < 0.01), 63% (P < 0.01), and 84% (P < 0.01) after one, two, and three treatments, respectively. Patients described moderate-to-marked improvement in acne, acne scarring, and post-inflammatory erythema. Adverse effects were limited to mild, transient erythema. CONCLUSIONS: The combination of the 595-nm pulsed-dye laser and the 1,450-nm diode laser is safe and effective for the treatment of inflammatory facial acne, acne scarring, and post-inflammatory erythema.

Acne Vulgaris↗

Laser evoked potentials using the Nd:YAG laser.

Pain-related cortical potentials were evoked by skin stimulation of the face and the limbs with 5-ns-duration laser pulses delivered by a Q-switched Nd:YAG laser. Such laser pulses, in the nanosecond range, were able to induce pinprick pain sensations and to evoke reproducible laser evoked potentials (LEPs) without visible skin lesions for an energy density of less than 18 mJ/mm(2). Low energy densities, around 10 mJ/mm(2), were sufficient to reach the pain threshold and to induce LEP. The mean conduction velocity of the stimulated afferent fibers was close to 20 m/s, consistent with the stimulation of Adelta fibers. The amplitude of LEP correlated with pain perception rather than with energy density. The differences, such as wavelength and stimulus duration, between the Q-switched Nd:YAG laser we used and the lasers that are currently used in LEP studies (i.e., CO(2), argon, or Tm:YAG lasers in the millisecond range) are discussed. Our study opens novel perspectives in the LEP field of research by using a new type of laser with a very short pulse duration.

Afferent Pathways↗

Lower energy endovenous laser ablation of the great saphenous vein with 980 nm diode laser in continuous mode.

PURPOSE: To assess clinical outcomes, complication rates, and unit energy applied using 980 nm diode endovenous laser treatment at 11 watts for symptomatic great saphenous vein (GSV) incompetence and reflux disease. METHODS: Thirty-four consecutive ablation therapies with a 980 nm diode endovenous laser at 11 watts were studied. The diagnosis of GSV incompetence with reflux was made by clinical evaluation and duplex Doppler examinations. The treated GSVs had a mean diameter of 1.19 cm (range 0.5-2.2 cm). The patients were followed with clinical evaluation and color flow duplex studies up to 18.5 months (mean 12.19 months +/- 4.18). RESULTS: Using 980 nm diode endovenous laser ablation in continuous mode, 100% technical success was noted. The mean length of GSVs treated was 33.82 cm (range 15-45 cm). The mean energy applied during the treatment was 1,155.81 joules (J) +/- 239.50 (range 545.40-1620 J) for a mean treatment duration of 90.77 sec +/- 21.77. The average laser fiber withdrawal speed was 0.35 cm/sec +/- 0.054. The mean energy applied per length of GSV was 35.16 J/cm +/- 8.43. Energy fluence, calculated separately for each patient, averaged 9.82 J/cm(2) +/- 4.97. At up to 18.5 months follow-up (mean 12.19 months), 0% recanalization was noted; 92% clinical improvement was achieved. There was no major complication. Minor complications included 1 patient with hematoma at the percutaneous venotomy site, 1 patient with thrombophlebitis on superficial tributary varices of the treated GSV, 24% ecchymoses, and 32% self-limiting hypersensitivity/tenderness/"pulling" sensation along the treatment area. One patient developed temporary paresthesia. Four endovenous laser ablation treatments (12%) were followed by adjunctive sclerotherapies for improved cosmetic results. CONCLUSION: Endovenous laser ablation treatment of GSV using a 980 nm diode laser at 11 watts in continuous mode appears safe and effective. Mean energy applied per treated GSV length of 35.16 J/cm or mean laser fluence of 9.82 J/cm(2) appears adequate, resulting in 0% recanalization and low minor complication rates.

Female↗

[Phacoemulsification and vitrectomy with the erbium:YAG laser and phacoemulsification with the neodymium:YAG laser].

There are an increasing number of possible applications for the use of Erbium:YAG and Neodymium:YAG lasers in ophthalmology. Laser-phacoemulsification as well as Erbium-laser vitrectomy is of major interest. We report on the underlying technology and more than 1-year-experience using the PHACOLASE (Asclepion-Meditec, Jena, Germany, 10-100 Hz frequency, 5-50 mJ single pulse energy) for phacoemulsification and pars plana vitrectomy and the Lyla-Dodick laser photolysis (A.R.C. Laser, Eckental-Forth, Germany, 1-20 Hz, up to 8 mJ single pulse energy). The Erbium:YAG-laser as well as the Neodymium:YAG-laser enabled us to extract lenses with up to medium hard nuclei. Moreover, the Erbium laser enabled fast vitrectomy with little mechanical traction. In many of our initial surgical operations we had to change to mechanical vitrectomy due to initial technical problems. No new complications occurred intra- or postoperatively. The handpiece worked well in removing vitreous bodies, but was not feasible for cutting membranes. Modified handpieces for this purpose are under development.

Equipment Design↗

Laser and non-laser light sources for photodynamic therapy.

Photodynamic therapy (PDT) is an anticancer combination therapy, which requires a photosensitiser, which tends to accumulate preferentially in the tumour, and light. Historically large, complex lasers have been used to carry out PDT treatment. Nowadays there is a wide range of coherent and non-coherent sources that can be used. This paper considers the important characteristics of light sources for PDT, including dye lasers pumped by argon or metal vapour lasers and frequency-doubled Nd:YAG lasers. Non-laser sources including tungsten filament, xenon arc, metal halide and fluorescent lamps are also discussed. New exciting developments such as LEDs and femtosecond lasers are also reviewed. The relative merits of laser and non-laser sources are critically examined.

Humans↗

A fiberoptic compatible midinfrared laser with CO2 laser-like effect: application to atherosclerosis.

In theory, pulses of laser light in the 2-microns range should ablate tissue in a manner similar to that of the 10.6-microns CO2 laser with the added advantage of efficient transmission through flexible quartz fibers. Using 200-microseconds pulses of 2.15-microns thulium-holmium-chromium:YAG (THC:YAG) laser light, we were able to create 700-microns-diameter holes through calcific atherosclerosis in vitro. In vivo evaluation of thrombogenicity and healing was accomplished by exposing the luminal surface of rabbit aortas to the THC:YAG laser. Serial histologic examinations of laser-treated rabbit aortae revealed a time course of resolution of the lesions which was very similar to that observed with like-sized lesions created with the same amount of continuous wave CO2 energy. No significant differences in thrombogenicity nor healing response were noted. The excellent in vivo response observed is due in part to the pulsed nature of the THC:YAG laser output as well as to the efficient tissue absorption at the 2.15-microns wavelength. We feel that excellent ablative effects with minimal collateral thermal damage can be obtained through fiberoptic delivery systems by taking advantage of laser wavelengths corresponding to the infrared absorption peak of water in the 2-microns region and pulsed delivery of the laser energy.

Animals↗