Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “LIGAMENTS, ARTICULAR”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13Linked to original sources

Validation of a three-dimensional model of the knee.

Three-dimensional mathematical models of the tibio-femoral joint require input of the geometry of articulating surfaces and ligament insertions, and the mechanical properties of cartilage and ligaments. This paper describes a validation of a knee model through a direct specimen-related comparison between the knee model and the kinematics of four knee joint specimens from which the geometry data were used as input of the model. The knee model is quasi-static and is based on equilibrium of forces and moments. The stiffness properties of the ligaments and articular cartilage were estimated on the basis of data reported in the literature. The so-called reference strains in the ligament bundles for the joint in extension, were determined by using an optimization procedure, minimizing the difference between the kinematics of the model and the kinematics of experimentally obtained flexion motions with an internally or an externally rotated tibia (+/- 3 Nm load). A reasonable to good agreement between the model and the experimental kinematics could be obtained for internal-external rotation laxity and the coupled translations and varus-valgus rotation. The disparity between model and experiment varied from knee to knee, average deviations ranging from close to zero to 8 degrees internal rotation deviation and from 5 mm posterior to 3 mm anterior position deviation. The average anterior-posterior laxities at both 20 degrees and 90 degrees flexion were within the variations reported in the literature, although for each individual joint with some underestimation or overestimation. It was concluded that the optimization procedure compensated for the lack of menisci and capsular structures by higher prestrains, thereby overestimating the ligament forces. Despite the gross simplifications relative to the complex anatomy of the knee, the present knee model can realistically simulate the passive motion characteristics of the human knee joint.

Elasticity↗

Wrist injuries: correlation of clinical and arthroscopic findings.

Wrist arthroscopy was done for one hundred nine patients with chronic wrist pain, averaging 22.8 months in duration. History regarding mechanism of injury, painful crepitus, pain with activity or at rest, localization of tenderness, visible swelling, and instability with examination was compared with arthroscopic findings of ligament damage, articular cartilage damage, and synovitis. Both pain at rest and swelling correlated significantly with synovitis. Tenderness did not correlate with specific ligament injury. Wrist ligament injuries and/or cartilage damage were noted in 96.3% of these wrists. Ligament injuries were frequently multiple, averaging 2.6 ligament injuries per wrist. No significant association was found between the presence of chondromalacia, synovitis, or specific ligament tears and the mechanism of injury, duration of symptoms, presence of clicking, or pain with activity.

Adolescent↗

Synovitis and osteoarthritic changes in canine articular cartilage after anterior cruciate ligament transection. Effect of surgical hemostasis.

Anterior cruciate ligament transection (ACLT) in the dog produces changes in the articular cartilage of the unstable knee that are consistent with those of osteoarthritis (OA). To determine whether the degrees of severity of OA cartilage changes, of synovitis, and of synovial iron deposition were related to adequacy of hemostasis at the time of ACLT, a modified surgical technique was devised, whereby electrocautery was used to obtain meticulous control of bleeding when the ligament was severed and irrigation was used to remove intraarticular blood before closure of the joint. When no particular attention was given to hemostasis, 69% of the dogs showed synovitis in the OA knee 10 weeks after ACLT; when electrocautery and irrigation were used to maintain hemostasis, synovitis was present in only 24% of the OA knees 10 weeks after ACLT (P less than 0.01). Iron deposits were present in 75% of synovial samples obtained after routine ACLT, but in only 6% (P less than 0.001) when attention was given to hemostasis. Hypertrophy of articular cartilage, chondrocyte cloning, fibrillation, and changes in tangential zone chondrocytes were less prominent in the OA knee when electrocautery and irrigation were used. However, the water content, uronic acid concentration, and rate of net 35S-labeled glycosaminoglycan synthesis were similarly increased regardless of the surgical technique used, and presumably, these changes reflect the reaction of joint cartilage to mechanical instability in this model of OA.

Animals↗

Biodegradable screw presents as a loose intra-articular body after anterior cruciate ligament reconstruction.

We report a case of intra-articular movement of a broken piece of a poly-L-lactide (PLLA) bioabsorbable interference screw from the femoral tunnel in anterior cruciate ligament (ACL) reconstruction with quadrupled semi-tendinosus and gracilis tendon grafts. Eleven months after initially successful ACL surgery, the patient felt a sudden locking of the knee without associated trauma or injury. The patient experienced pain and swelling episodes after heavy lifting with knee flexion at work, but without symptoms of giving way or locking. On revision arthroscopy, a broken part of a bioabsorbable interference screw was seen in the lateral compartment, which was subsequently removed without incident. The semitendinosus-gracilis graft appeared intact without disruption. After revision surgery, the patient's recovery was uneventful, with return to activity within a few months. This case further shows the problem of biointerference screw breakage in ACL reconstructive surgery and the need to bury the femoral bioabsorbable interference screw on graft fixation.

Absorbable Implants↗

Proteoglycan metabolism during repair of the ruptured medial collateral ligament in skeletally mature rabbits.

The metabolism of the chondroitin/dermatan sulfate (CS/DS) proteoglycans (PGs) decorin and biglycan is markedly altered during short-term (3-6 weeks) and long-term (40 weeks-2 years) repair of surgically ruptured medial collateral ligaments from mature rabbits. A PG-rich extracellular matrix accumulates in injury gaps by 3 weeks postsurgery and extends into tissue regions containing the original ligaments, and elevated PG levels remain apparent up to 2 years postinjury. CS/DS PGs were prepared from such ligaments and identified after SDS-polyacrylamide gel electrophoresis by Alcian blue staining or immunoblotting. In normal ligaments, decorin is the most abundant proteoglycan (accounting for approximately 80% of the total); the remainder is biglycan and a large PG, possibly versican. In repairing ligaments, decorin is barely detected, but instead a large proteoglycan and abundant amounts of biglycan accumulate. Biglycan is present in two forms in repairing ligaments, and they can be separated on SDS-PAGE into 200- and 140-kDa forms. The slower migrating species is absent in normal ligaments and may represent a different glycoform (containing either a single or two short chondroitin/dermatan sulfate chains) of biglycan. Alteration in PG expression and posttranslational processing during medial collateral ligament repair are similar to those reported for repair and scar formation of other connective tissues. The accumulation of biglycan observed here may interfere with proper collagen network remodeling and may lead to persistent inflammatory and matrix turnover processes, thus preventing restoration of a long-term functional ligament tissue.

Animals↗

Characterization of the mechanical behavior of human knee ligaments: a numerical-experimental approach.

During knee-joint motions, the fiber bundles of the knee ligaments are nonuniformly loaded in a recruitment pattern, which depends on successive relative orientations of the insertion sites. These fiber bundles vary with respect to length, orientation and mechanical properties. As a result, the stiffness characteristics of the ligaments as a whole are variable during knee-joint motion. The purpose of the present study is to characterize this variable mechanical behavior. It is hypothesized that for this purpose it is essential to consider the ligaments mechanically as multi-bundle structures in which the variability in fiber bundle characteristics is accounted for, rather than as one-dimensional structures. To verify this hypothesis, bone-ligament-bone preparations of the ligaments were subjected to series of unidirectional subfailure tensile tests in which the relative insertion orientations were varied. For each individual test specimen, this series of tensile tests was simulated with a mathematical ligament model. Geometrically, this model consists of multiple line elements, of which the insertions and orientations are anatomically based. In a mathematical optimization process, the unknown stiffness and recruitment parameters of the line elements are identified by fitting the variable stiffness characteristics of the model to those of the test series. Thus, lumped parameters are obtained which describe the mechanical behavior of the ligament as a function of the relative insertion orientation. This method of identification was applied to all four knee ligaments. In all cases, a satisfactory fit between experimental results and computer simulation was obtained, although the residual errors were lower for the cruciate ligaments (1.0-2.4%) than for the collateral ligaments (3.7-8.1%). It was found that models with three or less line elements were very sensitive to geometrical parameters, whereas models with more than 7 line elements suffered from mathematical redundancy. Between 4 and 7 line elements little difference was found. It is concluded that the present ligament models can realistically simulate the variable tensile behavior of human knee ligaments. Hereby the hypothesis is verified that it is essential to consider the ligaments of the knee as multi-bundle structures in order to characterize fully their mechanical behavior.

Aged↗

Evaluation of the anterior cruciate ligament, medial collateral ligament, achilles tendon and patellar tendon as cell sources for tissue-engineered ligament.

This study investigated four different connective tissue cell types to determine which cell type should be the source for seeding a tissue-engineered anterior cruciate ligament (ACL) replacement. Cells derived from the ACL, medial collateral ligament (MCL), achilles tendon (AT), and patellar tendon (PT) of New Zealand White rabbits were isolated and cultured. Each cell type was cultured in vitro after seeding on three-dimensional (3-D) braided polymer scaffolds and on tissue culture polystyrene that served as a control. Samples were evaluated and compared for their morphology, proliferation, and gene expression of fibronectin, type I and type III collagen. Scanning electron microscopy (SEM) photomicrographs verified cell attachment of all four types of connective tissue fibroblasts to the scaffolds. Preliminary results comparing proliferation indicate that cells obtained from the PT and AT have the fastest proliferation. Whereas gene expression of the phenotypic markers measured using real-time reverse transcription polymerase chain reaction (RT-PCR) indicates ACL cells have the highest gene expression for the matrix markers. This leads to the question of which cell type should be the cell source for tissue-engineering of ligament, the highly proliferating cells or the differentiated matrix producing cells. This study would suggest that ACL differentiated matrix producing cells are the most suitable cells for further study and development of a tissue-engineered ligament.

Achilles Tendon↗

Vascular adaptation of intact joint stabilizing structures in the posterior cruciate ligament deficient rabbit knee.

Loss of the posterior cruciate ligament (PCL) of the knee has a significant impact on joint stability and biomechanical function. Changes in joint biomechanics may result in mal-adaptive tissue degeneration and functional alteration of supporting ligaments. This study examines the effects of joint laxity on the vascular physiology of the intact anterior cruciate (ACL) and medial collateral (MCL) ligaments after PCL transection in rabbits.One-year-old female New Zealand white rabbits were assigned to control (n=12), sham-operated (n=12) or PCL transected (2, 6 or 16 weeks, n=12 per time point) groups. Half of the animals (n=6 per group) were used for ACL and MCL blood flow determination using coloured microsphere infusion (ml/min/100 g), and half were used for vascular volume determination (given as vascular index, micro l/g). In the MCL, PCL transection induced large, significant (4-5-fold) increases in blood flow (peak at 2 weeks) and vascular index (peak at 6 weeks) compared to sham-operated animals that returned towards control values by 16 weeks. In contrast, the ACL showed no increase in blood flow in lax joints, and a relatively small (2-fold) increase in vascular index at 6 weeks only. The wet weight and water content of both the MCL and ACL were significantly increased in PCL-deficient joints. We conclude that joint laxity (instability) subsequent to loss of the PCL in rabbits impacts the vascular physiology of intact supporting ligaments, inducing both vasomotor and angiogenic responses in the MCL. Changes in wet weight and water content of both the MCL and ACL demonstrate prolonged physiological adaptation of intact structures in lax joints.

Adaptation, Physiological↗

Does high-resolution MR imaging have better accuracy than standard MR imaging for evaluation of the triangular fibrocartilage complex?

We compared the findings of high-resolution MR imaging and standard MR imaging in the detection of tears of the triangular fibrocartilage in 33 patients with chronic wrist pain on the ulnar side. With arthroscopy as the standard of reference, sensitivity was 100%, specificity 53%, and accuracy 79% with the high-resolution MR imaging, against 83%, 67%, and 76% with the standard MR imaging. High-resolution MR imaging showed a higher sensitivity, but a decreased specificity in the assessment of the triangular fibrocartilage. The results showed that diagnosis of tears in the triangular fibrocartilage by MR imaging, even high-resolution MR imaging, is unsatisfactory, although further technological advances may well improve the accuracy.

Adult↗

Ligament grafts become more susceptible to creep within days after surgery: evidence for early enzymatic degradation of a ligament graft in a rabbit model.

Clinical evidence suggests that some ligament grafts stretch after surgery. Our purpose in this study was to quantify early postoperative creep behavior of ligament autografts in an animal model, and to explore potential mechanisms of that behavior. 38 New Zealand white rabbits underwent a unilateral, fresh, anatomic medial collateral ligament (MCL) autograft procedure and were killed immediately (time-zero), at 2 days, 3 weeks, or 8 weeks after surgery (n = 7-11 in each group). We compared the creep behavior of the autografts to normal MCLs (n = 8). An additional 7 MCL specimens were incubated for 2 days in a low concentration collagenase solution and then similarly creep-tested. All grafts were slower to recover their original length after creep than either normal ligaments or time-zero controls. These grafts started to become more vulnerable to elongation in cyclic and static creep tests within 2 days of surgery, compared to time-zero controls. This vulnerability to creep increased over the next 3 weeks, and was maintained at 8 weeks of healing. 2-day collagenase-soaked MCL specimens had the same creep strains as the 2-day autografts. These results suggest that even fresh anatomic ligament autografts become vulnerable to creep within a few days after surgery by mechanisms that may involve degradative enzymes such as collagenase.

Animals↗

The innervation of the triangular fibrocartilage complex: nitric acid maceration rediscovered.

Injury to the triangular fibrocartilage complex (TFCC) is frequently implicated in the etiology of ulnar-sided wrist pain. This study examines the nervous anatomy of the TFCC using a nitric acid maceration technique and attempts to correlate this information with known tear patterns. Ten fresh frozen cadaveric specimens were studied in detail. Gross dissection of each upper-extremity specimen included removal of all flexor and extensor tendons. After identification and labeling with permanent color of the ulnar nerve, dorsal sensory branch of the ulnar nerve, posterior interosseous nerve, anterior interosseous nerve, and median nerve, an en bloc excision of the distal radioulnar region was performed. Digestion of the soft tissue was performed with nitric acid at sequential concentrations of 50% and 33% for 9 of 10 specimens. The digestion was halted by immersing the specimen in a mixture of 10% formaldehyde and 1% glycerine. After removal of bone, the specimens were fixed in paraffin, sectioned, and stained with hematoxylin and eosin. Nine of the 10 specimens were studied microscopically to determine the contribution of the grossly identified nerves to each zone of the triangular fibrocartilage complex as defined by Palmer's classification of acute TFCC tears. The anterior interosseous, median, and superficial radial nerves did not contribute to the innervation of the TFCC. The intraarticular course of the peripheral nerves could not be defined in the one specimen that was not digested with nitric acid. Nitric acid maceration is a rediscovered technique for identifying the nervous anatomy of soft tissues. The study showed that the triangular fibrocartilage complex is innervated by branches of the posterior interosseous, ulnar, and dorsal sensory ulnar nerves in a fairly consistent manner. Improved treatment of TFCC tears may result from an enhanced understanding of the supporting structures' innervation and mechanical function.

Cartilage, Articular↗

Conservative and postoperative rehabilitation of isolated and combined injuries of the medial collateral ligament.

Injuries to the medial collateral ligament (MCL) are very common and there seems to be a consensus supporting the conservative management of grade I and II tears. Grade III tears are also usually treated conservatively unless associated with injuries to the anterior cruciate ligament or posterior cruciate ligament. This article outlines rehabilitation programs for conservative treatment of MCL injuries, and postoperative programs after anterior cruciate ligament or multiple ligament reconstruction. In addition, the use of functional and prophylactic bracing for injuries of the MCL is reviewed.

Anterior Cruciate Ligament Injuries↗