Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “High Throughput Screening”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13Linked to original sources

Visual and computational analysis of structure--activity relationships in high-throughput screening data.

Novel analytic methods are required to assimilate the large volumes of structural and bioassay data generated by combinatorial chemistry and high-throughput screening programmes in the pharmaceutical and agrochemical industries. Recent work in visualisation and data mining has been used to develop structure--activity relationships from such chemical-biological datasets.

Computational Biology↗

A cell-sparing electric field stimulation technique for high-throughput screening of voltage-gated ion channels.

The Trans Cell Layer Electrical Field Stimulation (TCL-EFS) system has been developed for high-throughput screening (HTS) of voltage-gated ion channels in microplate format on a Voltage-Ion Probe Reader (VIPR) platform. In this design, a wire electrode is placed above the cell layer of each filter well, and a whole plate perimeter electrode resides beneath the filter layer. This configuration allows the electrodes to be placed away from the cell layer to minimize the near electrode field effects on cell function and dye bleaching observed with other existing designs. Mathematical simulation indicates that the electric field at the cell layer becomes uniform as the top electrode is raised to a position near the surface of the solution in the well. Using the TCL-EFS system and membrane potential fluorescence resonance energy transfer (FRET) dyes, the sensitivity of voltage-gated sodium channels to tetrodotoxin and other channel inhibitors was found to be similar to those determined by established electrophysiological and more conventional VIPR techniques. A good correlation was also observed with the TCL-EFS system for inhibition of Cav2.2 by omega-conotoxin-GVIA and for block of Cav1.2 by known small molecule inhibitors. Thus, the TCLEFS system is suitable for both quantitative analysis and HTS of voltage-gated sodium and calcium channels, without the liabilities of previously reported EFS methodologies.

Calcium Channel Blockers↗

Validation of a fluorescent imaging plate reader membrane potential assay for high-throughput screening of glycine transporter modulators.

A fluorescent imaging plate reader (FLIPR) membrane potential (V(m)) assay was evaluated for pharmacological characterization and high-throughput screening (HTS) of rat glycine transporter type 2 (rGlyT(2)) in a stable rGlyT(2)-HEK cell line. Data show that glycine activation of rGlyT(2) consistently results in a concentration-dependent V(m) response on the FLIPR that is blocked by the potent and selective GlyT(2) antagonist 4-benzyloxy-3,5-dimethoxy-N-[1-dimethylamino-cyclopentyl)methyl]-benz-amide (Org-25543). Agonist and antagonist pharmacologies match those reported using conventional [(3)H]glycine uptake assays and electrophysiology. The glycine response is dependent on buffer ionic composition consistent with GlyT(2) physiology. Assay signal-to-background and coefficient of variation meets sufficient statistical criteria to conduct HTS. The results of a screen of the chemical inventory demonstrate that the assay is able to successfully identify and confirm GlyT(2) inhibitors. The advantages of this assay are its homogeneity, compatibility with both 96- and 384-well formats, and lack of radioactivity usage. Thus, the authors conclude that a fluorescence-based V(m) assay on FLIPR is a viable approach for identification and pharmacological profiling of small molecule modulators of the electrogenic transporter rGlyT(2).

Amino Acid Transport Systems, Neutral↗

Simple absorbance-based assays for ultra-high throughput screening.

In order to accommodate the predicted increase in screening required of successful pharmaceutical companies, miniaturized, high-speed HTS formats are necessary. Much emphasis has been placed on sensitive fluorescence techniques, but some systems, particularly enzymes interconverting small substrates, are likely to be refractory to such approaches. We show here that simple absorbance-based assays can be miniaturized to 10-microl volumes in 1536-well microplates compatible with the requirements for ultra-high throughput screening. We demonstrate that, with low-cost hardware, assay performance is wholly predictable from the 2-fold decrease in pathlength for fully filled 1536-well plates compared to 96- and 384-well microplates. A number of enzyme systems are shown to work in this high-density format, and the inhibition parameters determined are comparable with those in standard assay formats. We also demonstrate the utility of kinetics measurements in miniaturized format with improvements in assay quality and the ability to extract detailed mechanistic information about inhibitors.

Adenosine Triphosphatases↗

High-throughput screening and quantitative structure-efficacy relationship models of potential displacer molecules for ion-exchange systems.

A technique is presented for the high-throughput screening of ion-exchange displacers. Potential displacers were employed to displace proteins in parallel batch ion-exchange experiments. The percentage of protein displaced from a particular stationary phase was then used as a parameter to rank the displacers. By employing this technique, a large number of molecules possessing a range of affinities and properties could be rapidly evaluated. This data was then used together with traditional and electron density-based transferable atom equivalent (TAE) molecular descriptors computed for the displacer molecules to produce quantitative structure-efficacy relationship (QSER) models using a genetic algorithm/partial least squares (GA/PLS) regression approach. The QSER models were generated using a portion of the protein-displacement data, with the remainder serving as a test set. Descriptor selection and model building was accomplished using a genetic algorithm/partial least squares approach. The resulting models were found to have high-correlation coefficients and could be used to accurately predict the behavior of molecules not included in the training set. In addition, the models were employed to examine a virtual library of displacers based on modifications of neomycin to provide further insight into displacer design. The results presented here indicate that it may be possible to design displacers that can dramatically improve the effective selectivity of ion-exchange chromatographic materials.

Algorithms↗

Small molecules with antimicrobial activity against E. coli and P. aeruginosa identified by high-throughput screening.

BACKGROUND AND PURPOSE: New antimicrobials are needed because of the emergence of organisms that are resistant to available antimicrobials. The purpose of this study was to evaluate a high-throughput screening approach to identify antibacterials against two common disease-causing bacteria, and to determine the frequency, novelty, and potency of compounds with antibacterial activity. EXPERIMENTAL APPROACH: A high-throughput, turbidometric assay of bacterial growth in a 96-well plate format was used to screen a diverse collection of 150,000 small molecules for antibacterial activity against E. coli and P. aeruginosa. The statistical Z'-factor for the assay was > or = 0.7. KEY RESULTS: Screening for inhibition of E. coli growth gave a 'hit' rate (> 60% inhibition at 12.5 microM) of 0.025%, which was more than 5-fold reduced for P. aeruginosa. The most potent antibacterials (EC50 < 0.5 microM) were of the nitrofuran class followed by naphthalimide, salicylanilide, bipyridinium and quinoazolinediamine chemical classes. Screening of > 250 analogs of the most potent antibacterial classes established structure-activity data sets. CONCLUSIONS AND IMPLICATIONS: Our results validate and demonstrate the utility of a growth-based phenotype screen for rapid identification of small-molecule antibacterials. The favourable efficacy and structure-activity data for several of the antibacterial classes suggests their potential development for clinical use.

Anti-Bacterial Agents↗

Validation of FLIPR membrane potential dye for high throughput screening of potassium channel modulators.

A fluorescence-based assay using the FLIPR Membrane Potential Assay Kit (FMP) was evaluated for functional characterization and high throughput screening (HTS) of potassium channel (ATP-sensitive K+ channel; K(ATP)) modulators. The FMP dye permits a more sensitive evaluation of changes in membrane potential with a more rapid response time relative to DiBAC4(3). The time course of responses is comparable to ligand-evoked activation of the channel measured by patch-clamp studies. The pharmacological profile of the K+ channel evaluated by using reference K(ATP) channel openers is in good agreement with that derived previously by DiBAC4(3)-based FLIPR assays. Improved sensitivity of responses together with the diminished susceptibility to artifacts such as those evoked by fluorescent compounds or quenching agents makes the FMP dye an alternative choice for HTS screening of potassium channel modulators.

Animals↗

A Simple Statistical Parameter for Use in Evaluation and Validation of High Throughput Screening Assays.

The ability to identify active compounds (³hits²) from large chemical libraries accurately and rapidly has been the ultimate goal in developing high-throughput screening (HTS) assays. The ability to identify hits from a particular HTS assay depends largely on the suitability or quality of the assay used in the screening. The criteria or parameters for evaluating the ³suitability² of an HTS assay for hit identification are not well defined and hence it still remains difficult to compare the quality of assays directly. In this report, a screening window coefficient, called ³Z-factor,² is defined. This coefficient is reflective of both the assay signal dynamic range and the data variation associated with the signal measurements, and therefore is suitable for assay quality assessment. The Z-factor is a dimensionless, simple statistical characteristic for each HTS assay. The Z-factor provides a useful tool for comparison and evaluation of the quality of assays, and can be utilized in assay optimization and validation.

Journal Article↗

A rational utilization of high-throughput screening affords selective, orally bioavailable 1-benzyl-3-carboxyazetidine sphingosine-1-phosphate-1 receptor agonists.

Moderately potent, selective S1P(1) receptor agonists identified from high-throughput screening have been adapted into lipophilic tails for a class of orally bioavailable amino acid-based S1P(1) agonists represented by 7. Many of the new compounds are potent S1P(1) agonists that select against the S1P(2), S1P(3), and S1P(4) (although not S1P(5)) receptor subtypes. Analogues 18 and 24 are highly orally bioavailable and possess excellent pharmacokinetic profiles in the rat, dog, and rhesus monkey.

Administration, Oral↗

Purifying the masses: integrating prepurification quality control, high-throughput LC/MS purification, and compound plating to feed high-throughput screening.

In this paper we report using a parallel, four-channel HPLC/MUX/MS purification system, the Purification Factory, to purify thousands of compounds destined for high-throughput screening in a single month. The maximum sample throughput during this 20-workday month was 704 samples/day. Since this purification throughput exceeded the postpurification sample and data handling capabilities provided by commercial solutions, a custom-integrated solution was designed to address these shortcomings. In this paper we detail the key improvements in automation, solvent handling, and sample handling logistics implemented to sustain a mean throughput of 528 samples/day over a multimonth time period.

Autoanalysis↗

Functional expression of mammalian opioid receptors in insect cells and high-throughput screening platforms for receptor ligand mimetics.

Lepidopteran cell lines have been engineered to constitutively express high levels of mouse delta opioid receptors either alone or in combination with human Galpha16 protein. Biochemical and pharmacological studies demonstrate that these lines contain all the mediator G proteins and downstream effectors required for opioid receptor function, including phospholipase C, and that expression of exogenous Galpha16 does not contribute significantly to increased receptor responses upon activation. The activation of the phospholipase C pathway in the transformed cells upon stimulation with known receptor ligands results in easily and quantitatively measurable increases in free intracellular calcium, which can be monitored by automated fluorescent methods, while the addition of specific antagonists blocks the agonist-induced responses. Therefore, the transformed lepidopteran cell lines can be used as sensitive high-throughput screening platforms for fast detection of delta opioid receptor ligand mimetics (agonists and antagonists) in collections of natural products and synthetic compounds.

Animals↗

Development of a cell-based nanoluciferase reporter system for high-throughput screening of HBV cccDNA inhibitors.

Hepatitis B virus (HBV) persistence is sustained by the viral covalently closed circular DNA (cccDNA) minichromosome, which remains a major barrier to curative antiviral therapies. The lack of reliable quantitative cccDNA detection methods and surrogate markers has hindered efforts to target cccDNA in antiviral high-throughput screening (HTS). Here, we established a novel inducible cccDNA-dependent nanoluciferase (NLuc) reporter cell line, designated HepBLE12, by inserting an in-frame 11-amino acid split-NLuc HiBiT tag into the precore (pC) coding region of an HBV transgene. The resulting 1.3-kDa HiBiT tag on pC serves as the detection module of the split NLuc system, generating quantitative luminescence upon high-affinity complementation with the cognate 18-kDa LgBiT subunit in cell lysates. Notably, the HiBiT assay enables direct detection of intracellular HiBiT-pC protein rather than secreted HBeAg, providing a reporter signal more closely linked to cccDNA activity. HepBLE12&#x202f;cells exhibited inducible and robust viral DNA replication, and the cccDNA-dependent HiBiT signal was validated under diverse experimental conditions that modulate cccDNA formation or transcription. We further miniaturized the assay to a 384-well format and optimized key parameters following standard HTS assay development practices. The assay was successfully automated and demonstrated excellent performance in a multi-day variability study and a pilot screen, with signal-to-background (S/B)&#x202f;&#x2248;&#x202f;9, coefficient of variance (CV)&#x202f;<&#x202f;10%, and average Z-factor value of 0.74, exceeding canonical HTS quality benchmarks. Together, the HepBLE12 cell-based HTS platform provides a robust and practical tool for identifying inhibitors targeting HBV cccDNA.

Hepatitis B virus↗

High-throughput screening for enzyme inhibitors using frontal affinity chromatography with liquid chromatography and mass spectrometry.

This work presents new frontal affinity chromatography (FAC) methodologies for high-throughput screening of compound libraries, designed to increase screening rates and improve sensitivity and ruggedness in performance. A FAC column constructed around the enzyme N-acetylglucosaminyltransferase V (GnT-V) was implemented in the identification of potential enzyme inhibitors from two libraries of trisaccharides. Effluent from the FAC column was fractionated, sequentially processed via LC/MS, and referenced to a similar analysis through a control FAC column lacking the enzyme. The resulting multidimensional data sets were compared across corresponding sample and control fractions to identify binders, in a semiautomated approach. A strong binder in the protonated form at m/z 795 was identified from the first library of 81 compounds, exhibiting an estimated Kd value of 0.3 microM. Other binders yielded Kd values ranging from 0.35 to 3.35 microM. To demonstrate the improvement in performance of this FAC-LC/MS approach over the conventional online FAC/MS approach, 15 compounds from this library were blended with a second library of 1000 synthetic trisaccharides and screened against GnT-V. All ligands in the 15-compound set were identified in this larger screen, and no ligands of greater affinity than compound 1 were found. Our results show that FAC-LC/MS is a reliable method for screening large compound libraries directly and useful for large-scale ligand discovery initiatives.

Chromatography, Affinity↗

Discovery of a new family of chromium ethylene polymerisation catalysts using high throughput screening methodology.

Following a discovery that salicylaldimines bearing bulky ortho-phenoxy substituents and small imine substituents give very active chromium catalysts for ethylene polymerisation, High Throughput Screening (HTS) methodology has been employed to facilitate a further discovery of exceptionally active catalysts based on tridentate salicylaldimine ligands with bulky triptycenyl groups.

Journal Article↗

High-throughput screening with quantitation of ATP consumption: a universal non-radioisotope, homogeneous assay for protein kinase.

A number of assays have been developed for high-throughput screening (HTS) of potentially bioactive compounds. To screen millions of chemical compounds efficiently, the best detection technology prior to initiating HTS must be chosen. Ideally, a non-radioisotope (non-RI), homogeneous method, equivalent to the most reliable assay for a particular target, should be selected as an HTS method. Protein kinases are among the most important classes for drug discovery because they participate in various signaling pathways. Several HTS technologies are available for kinase activity: SPA (Amersham, Piscataway, NJ, U.S.A.), HTRF (CIS-US, Inc., Bedford, MA, U.S.A.), IMAP (Molecular Devices, Sunnyvale, CA, U.S.A.), and Z'-LYTE (Invitrogen, Carlsbad, CA, U.S.A.). The amount of phosphorylated product is detected by different methods in these assays. Recently, Kinase-Glo Luminescent Kinase Assay, a non-RI, homogeneous, adenosine triphosphate (ATP) quantitative kit useful for kinase activity detection, has become available from Promega (Madison, WI, U.S.A.). ATP is a universal substrate for kinases. Thus, the Kinase-Glo assay shows promise for becoming the primary method of determining kinase activity in HTS. We have developed a Kinase-Glo system for cyclin-dependent kinase 4 (Cdk4), and compare its results with those of the filtration method, the most reliable assay for in vitro Cdk4 activity. In addition, the reliability and sensitivity of the Kinase-Glo are discussed.

Adenosine Triphosphate↗

Fluorescence polarization and anisotropy in high throughput screening: perspectives and primer.

Fluorescence polarization and anisotropy are two nearly equivalent techniques that have together, over the past 5 years, achieved wide use in high throughput screening in drug discovery. These are single-label methods that can be used to construct homogeneous assays that are fast, sensitive, and resistant to some significant interferences. Moreover, the assays are relatively inexpensive. This review surveys the peer-reviewed literature on the subject and explores some of the fundamental issues that bear on assay performance.

Binding, Competitive↗

Development of a miniaturized 384-well high throughput screen for the detection of substrates of cytochrome P450 2D6 and 3A4 metabolism.

The identification of a large number of biologically active chemical entities during high throughput screening (HTS) necessitates the incorporation of new strategies to identify compounds with druglike properties early during the lead prioritization and development process. One of the major steps in lead prioritization is the assessment of drug metabolism mediated by the cytochrome P(450) (CYP) enzymes to evaluate the potential drug-drug interactions. CYP2D6 and CYP3A4 comprise the main human CYP enzymes involved in drug metabolism. The recent availability of specific CYP cDNA expression systems and the development of specific fluorescent probes have accelerated the ability to develop robust in vitro assays in HTS format. The aim of this study was to optimize conditions for the CYP2D6 and CYP3A4 HTS assays and subsequently adapt those assays to a miniaturized 384-well format. Assay conversion to a miniaturized format presents certain difficulties, such as robustness of the signal and of compound delivery. Thus the assay optimization involved the comparison of different substrates to identify those most suitable for use in a miniaturized format. Because of current technical limitations in liquid dispensing of nanoliter volumes, assay sensitivity to organic solvents also provides a main concern during assay miniaturization. Therefore, compound activity from redissolved dry films and from DMSO stocks directly delivered into assay buffer was compared. The data indicate that compound activity was comparable in both formats. The data support the conclusion that CYP2D6 and CYP3A4 in vitro metabolism assays can be successfully performed in 384-well plate format and the substrate potencies, as evaluated by the IC(50) values, determined.

Automation↗

The application of fluorescence lifetime readouts in high-throughput screening.

Measurement of fluorescence lifetime is a well-established technique, which has recently been introduced into the portfolio of assay formats used in high-throughput screening (HTS). This investigation establishes appropriate conditions for using lifetime measurements to reduce the impact of compound interference effects during large-scale HTS of corporate screening files. Experimental data on mixtures of standard fluorophores and interfering compounds (from 5 HTS campaigns) have been combined with a theoretical model to identify the minimum data quality required, defined by the photon count in the peak channel, for discrimination of biological activity. Single-component fluorophore lifetimes can be recovered with an error of 1%, with a peak photon count of 10(2), but the same accuracy with a 2-component decay requires a peak photon count of 10(3). When a 3rd component is introduced, the minimum peak count increases to 10(4). The influence of scattered light on lifetime determination was investigated using an emulsion (diameters 25-675 nm). The measured decays of interfering compounds, identified as autofluorescent, show that the vast majority have a very short lifetime that can readily be resolved from the reporter fluorophore, using appropriate data-fitting methods.

Drug Evaluation, Preclinical↗