Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “HARDNESS”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13Linked to original sources

[Occupation-related lung diseases in hard metal production and manufacturing. An allergic process?].

The clinical heterogeneity of hard metal disease lung with its two basic forms, i.e. hart metal pneumonitis and hard metal asthma, supports the view of different pathogenetic mechanisms. Cobalt, which is generally considered the noxious agent in hard metal diseases, is cytotoxic on the one hand and allergenic on the other. Four typical, extensively investigated cases are presented, i.e. hard metal pneumoconiosis, hypersensitivity pneumonitis, toxic-irritative hard metal asthma and allergic cobalt asthma. The immunological results were negative in the patient with hard metal pneumoconiosis. A hard metal grinder with typical occupational hypersensitivity pneumonitis showed a high level of precipitating antibodies against Aureobasidium pullulans, a well-known antigen in humidifier fever and sequoiosis. The inhalative provocation test induced on both patients with hard metal asthma an immediate and prolonged, i.e. a dual asthmatic reaction. Only the patient with allergic contact eczema due to cobalt and a positive epicutaneous test of the delayed type and a positive scratch tests of the immediate type with cobalt chloride.

Adult↗

Comparative hardness and modulus of tooth-colored restoratives: a depth-sensing microindentation study.

The objective of this study was to compare the hardness and modulus of the continuum of direct tooth-colored restorative materials using a depth-sensing microindentation approach. The effects of thermal fatigue on mechanical properties were also evaluated. Six restorative materials representing the continuum were selected. They included an ormocer (Admira [AM], Voco), a giomer (Beautifil [BF], Shofu), a compomer (Dyract Extra [DE], Dentsply), a minifill composite (Esthet-X [EX], Dentsply), resin-modified (Fuji II LC [FL], GC) and highly viscous (Fuji IX [FN], GC) glass ionomer cements (GICs). Fourteen specimens (3 mm wide x 3 mm long x 2 mm deep) were made for each material. The specimens were randomly divided into two groups and treated as follows: Group A--stored in distilled water at 37 degrees C for 30 days; Group B--thermal cycled for 5000 cycles (35 degrees C [28s], 15 degrees C [2s], 35 degrees C [28s], 45 degrees C [2s]) and stored for 26.5 days. Hardness and modulus of the materials were determined using depth-sensing microindentation testing with the Instron MicroTester. Hardness was computed by dividing the peak load over the maximum projected contact area while modulus was calculated by analysis of the loading/unloading load-displacement (P-h) curves and the analytical model according to Oliver and Pharr (J. Mater. Res. 7 (1992) 1564). Results were analyzed using ANOVA/Scheffe's post hoc test and independent samples T-test (p<0.05). Hardness ranged 46.44-72.65 and 49.11-78.97 HV, while modulus ranged 7.86-12.78 and 8.12-13.13 GPa for Groups A and B, respectively. Although the ranking of mechanical properties were generally similar for both groups, disparities in statistical differences between materials were observed between Groups A and B for both hardness and modulus. For both groups, BF was significantly harder than DE, AM, FL and EX was significantly harder than FL. The modulus of FN was significantly greater than EX, DE, AM and FL was significantly stiffer than AM. With the exception of BF, no significant change in hardness and modulus was observed for all materials with thermocycling. The hardness and modulus of some glass ionomer-based/containing materials may be comparable or even superior to minifill and ormocer composites. Thermal fatigue should be considered when comparing mechanical properties between materials.

Acrylic Resins↗

Monomer conversion and hardness of novel dental cements based on ethyl cyanoacrylate.

OBJECTIVES: The aim of this work was to study the setting of two novel dental cements: (i) a 'hybrid' cement, incorporating an ethyl cyanoacrylate into a glass-ionomer cement (ECGIC) formulation and (ii) an ethyl cyanoacrylate/hydroxyapatite composite cement (ECHC). The mechanical role of the cyanoacrylate and its curing within the cements have been discussed. METHODS: The setting of the cements was characterised using Vickers indentation hardness and near-infrared (near-IR) spectroscopy. RESULTS: The cyanoacrylate component of ECGIC was 100% cured approximately 10min after the initial cement mixing. The ECGIC continued to increase in hardness after the cyanoacrylate component was fully cured. This proved that the fully polymerised network of cyanoacrylate did not prevent the acid-base reactions of the GIC components from continuing. The Vickers hardness number of ECGIC at 18 weeks was approximately 105. The curing of the cyanoacrylate within ECHC was much slower and was still not complete (98%) 18 weeks after the initial cement mixing. The hardness of the ECHC was shown to be correlated with the extent of cyanoacrylate cure. The Vickers hardness number of ECHC at 18 weeks was approximately 21. The primary reasons for the overall lower hardness of ECHC in comparison to ECGIC were the lower powder:liquid ratio and the softer filler type. SIGNIFICANCE: Careful consideration is needed when incorporating cyanoacrylates into dental cements, as speed of cure and hardness are particularly important.

Cyanoacrylates↗

Evaluation of limb compartments with increased interstitial pressure. An improved noninvasive method for determining quantitative hardness.

The purpose of this project was to study a noninvasive method of evaluating limbs at risk of compartment syndrome. Untreated limb compartment syndrome may lead to irreversible dysfunction, chronic pain and contracture. An improved means of obtaining quantitative hardness measurements is reported. The handheld noninvasive compartment syndrome evaluator (NCSE) device formulates a quantitative hardness curve of force verse depth of indentation by applying a 5.0 mm diameter indenter to a limb muscle compartment. Eighteen volunteers (9 men, 9 women) had elevated intracompartmental interstitial pressures by application of custom-made tourniquets. Comparison of interstitial pressure to quantitative hardness measurements in 71 compartments tested showed a statistically significant strong linear relationship with an average Pearson correlation coefficient of .84 (range .78-.9 P<.0001). In addition, for all compartments tested, the mean hardness value for the group with interstitial pressure greater than 50 mmHg (considered compartment syndrome) was close to 2x greater and was statistically different than the mean hardness for the group with interstitial pressure less than 30 mmHg (no compartment syndrome, t-test: P<.0001). This study utilizes a device that has improved upon previous quantitative hardness measurement techniques. In addition, by utilizing a tourniquet model to create elevated interstitial intracompartmental pressure in volunteers, data collection was easier and faster. In the future, quantitative hardness measurements may accurately predict interstitial intracompartmental pressure for most patients. This technique may greatly enhance the medical community's ability to diagnose compartment syndrome with a noninvasive means.

Adult↗

Hardness of celluloid strip-finished or polished composite surfaces with time.

STATEMENT OF PROBLEM: An in-vitro study revealed that a celluloid strip-finished composite surface discolored more than the polished composite surface. Thus, the celluloid strip-finished composite surface may not cure enough compared with the polished composite surface. PURPOSE: This study tested the hypothesis that the celluloid strip-finished composite surface did not cure enough compared with the polished composite surface. METHODS AND MATERIAL: The composite was placed in a 1.5-mm thick aluminum mold and the upper surface was covered with a celluloid strip. Composite was light cured for 60 seconds, then a layer of approximately 200 microm thick was ground away from the lower surface and polished. The hardness of the upper composite surface that was polymerized under a celluloid strip and the polished lower surface were measured with Vickers hardness measuring instrument 15 minutes, 6 hours, and 6 days after light curing. The hardnesses of polished and celluloid strip-finished surfaces were compared using a paired t test. One-way ANOVA and Tukey was used for tests for the significant differences in hardnesses between 15 minutes, 6 hours, and 6 days after light curing for a given surface. RESULTS: Microhardness of the celluloid strip-finished composite surface was 380.6 N/mm(2) at 15 minutes, 442.5 N/mm(2) at 6 hours, and 519.2 N/mm(2) at 6 days after light curing. Microhardnesses of the polished composite surface was 476.6 N/mm(2) at 15 minutes, 511.7 N/mm(2) at 6 hours, and 535.0 N/mm(2) at 6 days after light curing. The hardness of the celluloid strip-opposed composite surface was significantly lower than that of the polished surface 15 minutes and 6 hours after light curing (P <. 001). There was no difference in hardness between the celluloid strip-opposed surface and the polished surface on the sixth day. CONCLUSION: The hardness of the celluloid strip-opposed composite surface was lower than that of the polished surface at 15 minutes and at 6 hours after light curing. However, there was no difference in microhardness in 6 days.

Analysis of Variance↗

Prediction of tablet hardness based on near infrared spectra of raw mixed powders by chemometrics.

The purpose of this research is to elucidate the effect of lubricant mixing on tablet hardness by near-infrared (NIR) chemometrics as a basic study of process analytical technology. Formulation cellulose (F-C) consisted of sulpyrine (SP), microcrystalline cellulose (MC), and magnesium stearate (MgSt). Formulation lactose/starch (F-L) consisted of SP bulk drug powder, spray-dried lactose (SL), corn starch (CS), and MgSt. First, F-L and F-C without MgSt were mixed in a twin-shell mixer for 60 min. MgSt was added to the mixed powder, and was mixed for various mixing times, after which the mixed powders were compressed by 8-mm diameter punch and die. NIR spectra of raw mixed powders of F-L and F-C were taken using a reflection type of Fourier transform NIR spectra spectrometer, and chemometric analysis was performed using principal component regression (PCR). The tablet hardnesses of F-L and F-C decreased with increasing mixing time. All NIR spectra of the mixed powders of F-L and F-C fluctuated depending on mixing time. In order to predict tablet hardness before tablet compression, NIR spectra of F-L and F-C mixed powders were analyzed and evaluated for hardness by PCR. The minimum standard error of cross-validation values could be realized by using five- and six-principal component models, respectively. In the cases of F-L and F-C, the relationships between the actual and predicted tablet hardnesses showed straight lines, respectively. In the regression vectors of F-L and FC, the peaks related to hydrogen groups of SP, CS, and MC appeared as positive peaks. In contrast, the peaks related to hydrocarbon due to MgSt appeared as negative peaks in the regression vectors. The calibration models to evaluate the tablet hardness were obtained based on NIR spectra of raw mixed powders by PCR. This approach to predicting tablet hardness prior to compression could be used as a routine test to indicate the quality of the final product without spending time and energy to produce samples of questionable quality.

Cellulose↗

Influence of placement techniques on Vickers and Knoop hardness of class II composite resin restorations.

OBJECTIVES: To analyze the influence of two placement techniques on Knoop and Vickers hardness of class II cavities restored using packable (A.L.E.R.T., Solitaire 2, SureFil) and conventional microfilled and hybrid (Filtek A110 and Z250, respectively) resin composites. METHODS: Fifty standardized class II cavities (5 x 3 x 1.5 mm3) were prepared in human premolars. They were divided into ten groups (n = 5) and restored according to each resin composite material (A.L.E.R.T., Solitaire 2, SureFil, Filtek A110 and Z250) and placement technique (incremental or bulk). After storage in distilled water at 37 degrees C for 24 h, they were thermal cycled (700 cycles/5-55 degrees C, 1 min dwell time) and sectioned longitudinally. One section from each specimen was embedded and polished for Knoop and Vickers hardness measurements. Sixteen indentations were performed for each restoration, eight on the occlusal and eight on the cervical surfaces. RESULTS: Results were submitted to ANOVA and demonstrated that all materials presented lower hardness values at the cervical surfaces when the bulk placement technique was employed, when compared to the occlusal surfaces (p< 0.001) whereas the same did not occur with the incremental technique. Pearson's correlation test demonstrated a positive correlation between Vickers and Knoop hardness numbers. SIGNIFICANCE: The use of bulk placement technique resulted in lower values of hardness at the cervical surfaces of class II restorations. Values obtained using Knoop hardness test showed a high correlation with Vickers hardness measurements.

Analysis of Variance↗

Titanium orthodontic brackets: structure, composition, hardness and ionic release.

OBJECTIVES: The aim of the present study was to investigate the composition, morphology, bulk structure and ionic release of two brands of titanium orthodontic brackets: Orthos2 (Ormco, USA) and Rematitan (Dentaurum, Germany). METHODS: Five specimens of each group were examined with computerized X-ray microtomography, to reveal the morphology and structure of brackets, whilst resin-embedded and metallographically polished specimens were subjected to SEM/EDS analysis and Vickers microhardness measurements. Brackets were also maintained in 0.9% saline for 2 months and the ionic release in the immersion medium was determined with Inductively Coupled Plasma Atomic Emission Spectroscopy. The results of the hardness and ionic release measurements were statistically analyzed with two-way ANOVA and Tukey's test (alpha = 0.05). RESULTS: Orthos2 brackets consisted of two parts, the base (commercially pure Ti grade II) and the wing (Ti-6Al-4V alloy), joined together by laser welding, producing large gaps along the base-wing interface. The base was of lower hardness (Hv = 145), than the wing (Hv = 392) and incorporated a standard foil base-mesh pad. Rematitan brackets consisted of commercially pure Ti grade IV, with a single-piece manufacturing pattern of virtually identical hardness (p > 0.05) at the base and wings, featuring a laser-etched base-mesh pad. The hardness of the Rematitan brackets was significantly lower than the hardness of the Orthos2 wings, but double the hardness of the Orthos2 base. Released Ti levels were below the threshold level (1 ng/ml) of analysis for both materials, whilst traces of Al (3 ppm) and V (2 ppm) were found in the immersion media for Ti-6Al-4V alloy. SIGNIFICANCE: The structural and hardness differences found may influence the torque transfer characteristics from activated archwires to the brackets and the crevice corrosion potential at the base-wing interface (Orthos2). The detection of Al and V in the immersion medium (Orthos2) may imply a different biological response from the two types of Ti brackets.

Alloys↗

Lack of association between water hardness and coronary heart disease mortality in Japan.

BACKGROUND: Elevated levels of water hardness are related to lower mortality from coronary heart disease (CHD) in different populations. This ecologic study assessed whether water hardness is related to lower mortality from CHD in Osaka Prefecture, with 44 municipalities, Japan. METHODS: The mortality rate from CHD per municipality was calculated based on the number of coronary deaths and midyear population in 1995. Values for water hardness in each of the municipalities were estimated based on the yearly amount of water supply per source and the yearly average of water hardness for each source in 1997. Multiple logistic regression analysis was used to control socioeconomic status and health care status in each municipality. RESULTS: In males, after adjustment for age, an inverse dose-response relationship between water hardness and mortality from CHD was significant (P for linear trend=0.004). However, this relationship virtually disappeared after further adjusting for socioeconomic status and health care status. In females, there was no material association between water hardness and coronary mortality. CONCLUSIONS: This study provides no evidence that water hardness is preventive against mortality from CHD in Japan.

Adolescent↗

Analysis of muscle hardness in patients with masticatory myofascial pain.

PURPOSE: The aim of the present study was to access any changes in the muscle hardness of the masseter muscle between normal subjects and patients with myofascial pain during brief sustained isometric contractions at various bite force levels, and to compare muscle hardness, especially in terms of the recovery phase, after a clenching task. MATERIALS AND METHODS: Ten patients with masticatory myofascial pain and 10 age- and weight-matched normal healthy controls participated in this study. First, the hardness of the right masseter muscle was measured at the bite force of 0, 3, 6, and 9 kgf with a hand-held hardness meter. Then, the subjects were requested to exert a 9 kgf-clenching task for 30 seconds. The muscle hardness was again measured at 5, 30, and 120 seconds after the task, and the data obtained were compared with the muscle hardness before the clenching task. RESULTS: The results showed that there was no significant difference between the patients and the normal controls, while the muscle hardness increased with contraction in all subjects. The present findings also showed that the patients had a delayed return to baseline after the clenching task compared with the normal subjects, although an immediate increase after the clenching task was seen in all subjects. CONCLUSION: The results indicated that patients with masticatory myofascial pain have different muscle properties in the recovery phase after contraction, probably because of a slower intramuscular reperfusion.

Adult↗

Hardness and strength of endodontic files and reamers.

No information could be found in the dental literature on the hardness or strength of the materials in root canal instruments. Hardness testing is a convenient method for examining these products, and strength properties can be deduced from available strength-hardness data. The Vickers hardness of cross-sections of stainless steel root canal files and reamers #15 and #40 made by three well-known manufacturers were determined. Significant differences in hardness were found between manufacturers and between the two sizes of two manufacturers' products. The Vickers hardness range was from 400 to 651, exceeding the range permitted by the AS 1411, and falling below the hardness required for many cutting instruments. The measurements indicate that the instruments are made from high-strength wire. The values obtained suggest that the properties of materials used for some endodontic files could be improved and provide a basis for the selection of superior materials for the future.

Analysis of Variance↗

Effect of geometric structure and surface wettability of glidant on tablet hardness.

The aim of this study is to investigate the effect of geometric structure and surface wettability of glidant on tablet hardness. Geometric structure is defined, in this work, as three-dimensional structure such as porosity, particle size and specific surface area. A variety of silica was incorporated in direct compressive fillers as glidant and mixed powder was compressed in single punch tablet machine with and without 0.5 wt.% magnesium stearate. Flowability of mixed powder was evaluated with Carr's index measurement. In the case of unlubricated compression, tablet hardness decreased as a function of additional concentration of silica. Reduction rate directly depended on surface coverage of silica over filler surface and hydrophobicity. Since surface coverage is related to geometric structure, it can be concluded that structural influence plays an important role to determine tablet hardness. While, in the case of lubricated compression, either water adsorption amount or geometric structure effects on tablet hardness. Increase of tablet hardness was observed only when hydrophilic porous and small size nonporous silica were added. All the other silica had deleterious effect on tablet hardness and in particular hydrophobicity strongly reduced tablet hardness.

Adsorption↗

Nondestructive tablet hardness testing by near-infrared spectroscopy: a new and robust spectral best-fit algorithm.

A new algorithm using common statistics was proposed for nondestructive near-infrared (near-IR) spectroscopic tablet hardness testing over a range of tablet potencies. The spectral features that allow near-IR tablet hardness testing were evaluated. Cimetidine tablets of 1-20% potency and 1-7 kp hardness were used for the development and testing of a new spectral best-fit algorithm for tablet hardness prediction. Actual tablet hardness values determined via a destructive diametral crushing test were used for construction of calibration models using principal component analysis/principal component regression (PCA/PCR) or the new algorithm. Both methods allowed the prediction of tablet hardness over the range of potencies studied. The spectral best-fit method compared favorably to the multivariate PCA/PCR method, but was easier to develop. The new approach offers advantages over wavelength-based regression models because the calculation of a spectral slope averages out the influence of individual spectral absorbance bands. The ability to generalize the hardness calibration over a range of potencies confirms the robust nature of the method.

Algorithms↗

fMRI-derived cortical maps for haptic shape, texture, and hardness.

We used functional magnetic resonance imaging (fMRI) to investigate the neural substrates involved in haptic processing of texture, shape, and hardness. Subjects performed haptic classification tasks on a set of 27 silicone objects having parametrically defined shape, texture, and hardness. The objects were ellipsoids of revolution in which the ratio of the long to the short axis was varied, producing three different shapes. Three surface textures and three hardness levels were used. In three separate experiments, the same subjects classified each object along the three levels of one of the object properties (shape, texture, or hardness). Texture, shape, and hardness processing led to contralateral activation in the postcentral gyrus (PCG). A common region located within relatively posterior portions of the PCG was observed during shape and texture identification whereas a separate and more anterior region was activated during the hardness identification task. The hardness identification task also produced bilateral activation within the parietal operculum.

Adult↗

A comparison of the wear resistance and hardness of indirect composite resins.

STATEMENT OF PROBLEM: Various new, second-generation indirect composites have been developed with claimed advantages over existing tooth-colored restorative materials. To date, little independent research has been published on these materials, and the properties specified in the advertising materials are largely derived from in-house or contracted testing. PURPOSE: Four second-generation indirect composites (Artglass, belleGlass, Sculpture, and Targis) were tested for wear resistance and hardness against 2 control materials with well-documented clinical application. Human enamel was also tested for comparison. MATERIAL AND METHODS: Twelve specimens of each material were fabricated according to the manufacturers' directions and subjected to accelerated wear in a 3-body abrasion, toothbrushing apparatus. Vickers hardness was measured for each of the tested materials, and energy dispersive x-ray (EDX) spectroscopy was performed to determine the elemental composition of the composite fillers. The statistical tests used for wear and hardness were the Kruskal-Wallis 1-way ANOVA test with Mann-Whitney tests and 1-way ANOVA with multiple comparisons (Tukey HSD). The Pearson correlation coefficient was used to determine the existence of a relationship between the hardness of the materials and the degree to which they had worn. The level of statistical significance chosen was alpha=.05. RESULTS: The control material Concept was superior to the other composites in wear resistance and hardness and had the lowest surface roughness. Significant relationships were observed between depth of wear and hardness and between depth of wear and average surface roughness. Enamel specimens were harder and more wear resistant than any of the composites. EDX spectroscopy revealed that the elemental composition of the fillers of the 4 new composites was almost identical, as was the composition of the 2 control composites. CONCLUSION: The differences in wear, hardness, and average surface roughness may have been due to differences in the chemistry or method of polymerization of the composites. Further research in this area should be encouraged. It was also apparent that the filler present in the tested composites did not exactly fit the manufacturers' descriptions.

Acrylic Resins↗

The effect of thermocycling on the fracture toughness and hardness of core buildup materials.

STATEMENT OF PROBLEM: Thermocycling has been shown to cause surface degradation of many dental materials, but its effect on the fracture toughness and hardness of direct core buildup materials is unknown. PURPOSE: This study was designed to determine the effect of thermocycling on the fracture toughness and hardness of 5 core buildup materials. MATERIAL AND METHODS: Fifteen specimens were prepared from each of the following materials: Fluorocore, VariGlass VLC, Valiant PhD, Vitremer, and Chelon-Silver. American Standard for Testing Materials guidelines for single-edge notch, bar-shaped specimens were used. Ten specimens of each material were thermocycled for 2000 cycles; the other 5 specimens were not thermocycled. All specimens were subjected to 3-point bending in a universal testing machine. The load at fracture was recorded, and the fracture toughness (K(IC)) was calculated. Barcol hardness values were also determined. Data were analyzed with 1-way analysis of variance and compared with the Tukey multiple range test (P<.05). Pearson's correlation coefficient was also calculated to measure the association between fracture toughness and hardness. RESULTS: Fluorocore had the highest thermocycled mean K(IC) and Valiant PhD the highest non-thermocycled K(IC). Chelon-Silver demonstrated the lowest mean K(IC) both before and after thermocycling. One-way analysis of variance demonstrated significant differences between conditions, and the Tukey test showed significant differences (P<.05) between materials for both conditions. Most specimens also showed significant hardness differences between conditions. Pearson's correlation coefficient indicated only a mild-to-moderate correlation between hardness and fracture toughness. CONCLUSION: Within the limitations of this study, the thermocycling process negatively affected the fracture toughness and hardness of the core buildup materials tested.

Acrylic Resins↗

Prediction of drug content and hardness of intact tablets using artificial neural network and near-infrared spectroscopy.

The purpose of this study was to predict drug content and hardness of intact tablets using artificial neural networks (ANN) and near-infrared spectroscopy (NIRS). Tablets for the drug content study were compressed from mixtures of Avicel PH-101, 0.5% magnesium stearate, and varying concentrations (0%, 1%, 2%, 5%, 10%, 20%, and 40% w/w) of theophylline. Tablets for the hardness study were compressed from mixtures of Avicel PH-101 and 0.5% magnesium stearate at varying compression forces ranging from 0.4 to 1 ton. An Intact Analyzer was used to obtain near infrared spectra from the tablets with varying drug contents, whereas a Rapid Content Analyzer (RCA) was used to obtain spectral data from the tablets with varying hardness. Two sets of tablets from each batch (i.e., tablets with varying drug content and hardness) were randomly selected. One set of tablets was used to generate appropriate calibration models, while the other set was used as the unknown (test) set. A total of 10 ANN calibration models (5 each with 10 and 160 inputs at appropriate wavelengths) and five separate 4-factor partial least squares (PLS) calibration models were generated to predict drug contents of the test tablets from the spectral data. For the prediction of tablet hardness, two ANN calibration models (one each with 10 and 160 inputs) and two 4-factor PLS calibration models were generated and used to predict the hardness of test tablets. The PLS calibration models were generated using Vision software. Prediction of drug contents of test tablets using the ANN calibration models generated with 10 inputs was significantly better than the prediction obtained with the ANN calibration models with 160 inputs. For tablets with low drug concentrations (less than or equal to 2% w/w) prediction of drug content was better with either of the two ANN calibration models than with the PLS calibration models. However, prediction of drug contents of tablets with greater than or equal to 5% w/w drug was better with the PLS calibration models than with the ANN calibration models. Prediction of tablet hardness was better with the ANN calibration models generated with either 10 or 160 inputs than with the PLS calibration models. This work demonstrated that a well-trained ANN model is a powerful alternative technique for analysis of NIRS data. Moreover, the technique could be used in instances when the conventional modeling of data does not work adequately.

Calibration↗

Hardness evaluation of penile prostheses.

AIM: This work investigates the hardness and buckling force of penile prostheses to further understand the rigidity of penile prostheses before and after implantation. METHODS: Evaluated herein are four prosthetic samples (three inflatable, one semi-rigid), five real prostheses (one inflatable, four semi-rigid), and one prosthesis after implantation. The hardness is measured with a Shore Durimeter by pressing the tester's indentor to the surface of the specimen. A volunteer with inflatable prosthesis implantation is evaluated with respect to penile hardness versus various numbers of pumping. The buckling force of the prosthesis is also determined by a push-pull gauge and a specially designed sampling table. RESULTS: Results in this study demonstrate that although the inflatable prosthesis could only be pumped to a certain amount of hardness, hardness and buckling force correlate well with each other. After reaching the hardness limit, prostheses can even be pumped a further few times. However, continuous pumping only puts more tension on the prosthetic material without increasing hardness and could induce mechanical failure of the prosthesis. Results also indicate that the buckling force decreases with increasing length of the semirigid prostheses, and increases when the prosthesis has a larger diameter. CONCLUSION: This mechanical measurement of rigidity in penile prostheses could provide more information to clinicians about the penile prosthesis before surgical implantation, and to patients about prosthesis usage after implantation.

Hardness Tests↗