Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “ELECTROSURGERY”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13Linked to original sources

Laparoscopic ureterocalicostomy: development of a technique simplified by application of Nitinol clips and a wet monopolar electrosurgery device.

PURPOSE: We developed a technique for laparoscopic ureterocalicostomy with the use of intracorporeal suturing and subsequently simplified the technique by application of experimental Nitinol clips. MATERIALS AND METHODS: We performed laparoscopic ureterocalicostomy on 16 domestic swine divided into four groups of four animals each. The kidney was exposed laparoscopically, and the renal artery was atraumatically clamped. The lower pole of the kidney was amputated to expose a lower-pole calix, and hemostasis of the cut renal surface was obtained with a wet monopolar electrosurgical device (Floating Ball device [FB]; TissueLink, Dover, NH). Anastomosis of the ureter to the lower-pole calix was performed over a guidewire using 3-0 Vicryl suture in group 1 and Nitinol clips in group 3. A double-J ureteral stent was then deployed retrograde under fluoroscopic guidance. In addition, we evaluated the use of fibrin glue as a sealant over the sutured or clipped anastomotic site (groups 2 and 4, respectively). Ureteral stents were removed after 3 weeks, and the animals were evaluated and sacrificed after an additional 3 weeks. RESULTS: Laparoscopic ureterocalicostomy was completed in all 16 animals. In each case, excellent renal parenchymal hemostasis was obtained with the FB device, with a mean hemostasis time of 4.1 minutes. The mean anastomotic time with standard suture reconstruction was 37.1 +/- 5.4 minutes, while the anastomotic time with the Nitinol clips was 29.0 +/- 8.0 minutes (P = 0.0339). Retrograde pyelograms in groups 1 and 3 (no fibrin glue) showed a patent anastomosis with no hydronephrosis in three of the four animals in each group. One animal in group 1 and one animal in group 3 developed large urinomas secondary to anastomotic failure. The animals that received fibrin glue over the anastomotic site (groups 2 and 4) all showed narrowed anastomoses with severe hydronephrosis. CONCLUSIONS: With available instrumentation, laparoscopic ureterocalicostomy is technically feasible. Nitinol clip technology significantly reduces collecting-system reconstruction time. Application of fibrin glue as a urinary tract sealant resulted in an unexpected adverse outcome.

Alloys↗

Electrosurgery: principles and safety issues.

The use of monopolar electrosurgical energy has been the "gold standard" for the past 50 years. It has diverse capabilities, such as fulguration, precise vaporization, and coaptation of large vessels. Technologic advances in performance and safety have positioned this device as a useful tool in a surgeon's armamentarium. The adaptation of active electrode monitoring for stray energy as a result of insulation failure or capacitive coupling and the use of completely metal trocar cannulas will increase the confidence of the surgeon and the safety of his/ her patient. It is the author's opinion that its use will prove itself in laparoscopy. As with any surgical tool or energy source, education and skill are required. This introduction on the principal of the biophysics of electrical energy on tissue and the safety consideration is a start to further one's understanding of this surgical tool.

Biophysical Phenomena↗

Effects of steel scalpel, ultrasonic scalpel, CO2 laser, and monopolar and bipolar electrosurgery on wound healing in guinea pig oral mucosa.

OBJECTIVE: The study's objective was to compare instrument performance and tissue healing when steel scalpel, ultrasonic scalpel, monopolar or bipolar electrosurgical instruments, or CO2 laser was used in an animal oral surgery model. STUDY DESIGN: Prospective, blinded, randomized. METHODS: Adult guinea pigs (N = 70) were randomly assigned to 5 groups (14 animals per group) for excision of 2-cm, full-thickness oral mucosa using steel scalpel, ultrasonic scalpel, monopolar or bipolar electrosurgical instruments, or CO2 laser. Postoperative pain was measured indirectly using weekly body weight changes. Animals from each group were killed on days 0, 7, 14, 21, and 28. Specimens were harvested for blinded histopathological study and tensile strength measurement. Instrument performance (hemostasis, tissue coagulation, tissue sticking) and wound healing (tissue re-epithelialization, degree of inflammation) were primary outcomes. Statistical analysis was performed using analysis of variance. RESULTS: The ultrasonic scalpel was the best tool in controlling hemostasis, tissue coagulation, and tissue sticking. Significantly higher body weight gain ( P<.05) was noted at day 7 for monopolar and CO2 laser groups. Greatest tensile strength was seen in the steel scalpel and ultrasonic scalpel groups at the end of 28 days. Tissue re-epithelialization was fastest for the steel scalpel and ultrasonic scalpel groups (complete by day 7). Complete re-epithelialization of wounds of all treatment groups occurred by day 28. All groups had acute inflammation. Complete resolution of inflammation by day 14 took place in the steel scalpel and ultrasonic scalpel groups only. CONCLUSION: Use of the ultrasonic scalpel produced faster re-epithelialization and greater tensile strength than laser or electrosurgical instruments, with results comparable to those seen with the steel scalpel.

Animals↗

Evaluation of a vessel sealing system, bipolar electrosurgery, harmonic scalpel, titanium clips, endoscopic gastrointestinal anastomosis vascular staples and sutures for arterial and venous ligation in a porcine model.

PURPOSE: We assessed the usefulness of the LigaSure (Valleylab, Boulder, Colorado) vessel sealing system for vascular control during laparoscopic surgery and compared it with other available hemostatic modalities. MATERIALS AND METHODS: A total of 31 domestic pigs were divided into 5 groups. In groups 1 and 2 the vessel sealing system was compared with titanium clips and Endo-GIA (United States Surgical, Stamford, Connecticut) staples. In group 3 the vessel sealing system was compared with standard Klepinger (Karl Storz, Culver City, California) bipolar forceps. In group 4 the harmonic scalpel and Trimax (United States Surgical) bipolar forceps were compared. In group 5 in vivo laparoscopic application of the vessel sealing system was evaluated. RESULTS: The 5 mm. laparoscopic vessel sealing system sealed arteries up to 6 mm. and veins up to 12 mm. in diameter at supraphysiological bursting pressure. We evaluated 13 arteries with a diameter of 6 mm. or less at a mean bursting pressure of 662 mm. Hg (range 363 to 1,985) and 11 veins with a diameter of 12 mm. or less with a mean bursting pressure of 233 mm. Hg (range 63 to 440). Collateral tissue damage extended 1 to 3 mm. from the application site. Standard bipolar energy with Klepinger and Trimax forceps was less reliable and in some cases vessel sealing could not be accurately assessed before vessel division. Collateral tissue injury was 1 to 6 mm. The harmonic scalpel did not reliably seal vessels larger than 3 mm. but resulted in the least acute collateral tissue injury of 0 to 1 mm. CONCLUSIONS: In the porcine model the LigaSure system is a viable option for laparoscopic management of arteries up to 6 mm. and veins up to 12 mm. in diameter.

Anastomosis, Surgical↗

Electrosurgery in patients with pacemakers/implanted cardioverter defibrillators.

Despite improved protective mechanisms, pacemakers and implanted cardioverter defibrillators are subject to interference from various sources. An effective means of hemostasis, electrocautery generates electromagnetic interference and may be problematic in this patient population. Reported complication rates are low, but the consequences can be serious. Recommendations regarding the management of patients with implanted cardiac devices become increasingly significant both as the number of patients with devices increases and the number of out-of-hospital/minor surgery procedures performed increases. This article provides surgeons and anesthetists with practical recommendations for use of electrocautery in patients with pacemakers or implantable cardiac defibrillators.

Defibrillators, Implantable↗

Electrosurgery using insulated needles: epilation.

This paper deals mainly with histologic findings and clinical aspects of epilation using insulated needles. Patients were checked for hair regrowth after "thermolysis" epilation--a cycle of three to four treatments at roughly 3-month intervals, within an observation period of 2 1/2 years. The results for 39 patients, compiled 6 months to 1 year after the final epilations, showed almost no or extremely reduced hair regrowth with almost no scarring.

Electrosurgery↗