Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “DENTURE BASES”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13Linked to original sources

[Case report of a patient treated with unilateral extension base denture using the altered cast technique].

PATIENT: The patient was a 70-year-old male with a chief complaint of poor adaptation of a mandibular unilateral extension base denture. The diagnosis was missing teeth of the mandibular bilateral second premolars, the first molars and the mandibular left second molar as well as poorly-fitting facing crowns in the mandibular bilateral canines and the first premolars. After inserting the facing crowns, a metal base denture was constructed using the altered cast technique. After 3 years, the metal base denture's masticatory function and appearance were successfully achieved. DISCUSSION: It was considered an achievement in this case to get maximum support from the residual ridge using the altered cast technique. CONCLUSION: The metal base denture was constructed using the altered cast technique and successful masticatory function was gained.

Aged↗

Effect of a new tension system, used in acrylic resin flasking, on the dimensional stability of denture bases.

STATEMENT OF PROBLEM: The pressure of final closure may be released when the flask is removed from the mechanical or pneumatic press and placed in the spring clamp. This release in pressure may result in dimensional changes that distort the denture base. PURPOSE: The purpose of this study was to investigate differences between the dimensional stability of standardized simulated denture bases processed by traditional moist heat-polymerization and those processed by use of a new tension system. MATERIAL AND METHODS: A metal master die was fabricated to simulate an edentulous maxillary arch without irregularities in the alveolar ridge walls. A silicone mold of this metallic die was prepared, and 40 stone casts were formed from the mold with type III dental stone. The casts were randomly assigned to 4 test groups (A-D) of 10 specimens each. A uniform denture base pattern was made on each stone cast with a 1.5-mm thickness of base-plate wax, measured with a caliper. The patterns were invested for traditional hot water processing. A polymethyl methacrylate dough was prepared and packed for processing. The flasks in groups A and B were closed with the traditional pressure technique and placed in spring clamps after final closure. The flasks in groups C and D were pressed between the metallic plates of the new tension system after the final closure. The group A and C flasks were immediately immersed in the water processing unit at room temperature (25 degrees +/- 2 degrees C). The unit was programmed to raise the temperature to 74 degrees C over 1 hour, and then maintained the temperature at 74 degrees C for 8 hours. The group B and D flasks were bench stored at room temperature (25 degrees +/- 2 degrees C) for 6 hours and were then subjected to the same moist heat polymerization conditions as groups A and C. All processed dentures were bench cooled for 3 hours. After recovery from the flasks, the base-cast sets were transversally sectioned into 3 parts (corresponding to 3 zones): (1) distal of the canines, (2) mesial of the first molars, and (3) mesial of the posterior palate). These areas had been previously established and standardized by use of a pattern denture in the sawing device to determine the sections in each base-cast set. Base-cast gaps were measured at 5 predetermined points on each section with an optical micrometer that had a tolerance of 0.001 mm. Collected data were analyzed with analysis of variance and Tukey's test. RESULTS: Denture bases processed with the new tension system exhibited significantly better base adaptation than those processed with traditional acrylic resin packing. Immediately after polymerization (Groups A and C), mean dimensional change values were 0.213 +/- 0.055 mm for the traditional packing technique and 0.173 +/- 0.050 mm for new tension system. After delayed polymerization (Groups B and D), the values were 0.216 +/- 0.074 mm for the traditional packing technique and 0.164 +/- 0.032 mm for new tension system. With both techniques, dimensional changes in the posterior palatal zone were greater (conventional = 0.286 +/- 0.038 mm; new system = 0.214 +/- 0.024 mm) than those elsewhere on the base-cast set. CONCLUSION: Within the limitations of this study, the new tension packing system was associated with decreased dimensional changes in the simulated maxillary denture bases processed with heat-polymerization.

Acrylic Resins↗

Cytotoxic effects of denture base materials on a permanent human oral epithelial cell line and on primary human oral fibroblasts in vitro.

PURPOSE: The objective of this study was to determine the cytocompatibility of three different extracts of denture base resins and to compare the cytotoxic effect of these materials on a human oral epithelial KB cell line and primary human oral fibroblasts derived from buccal mucosa. MATERIALS AND METHODS: Set specimens from a heat-cured resin, a self-cured resin, and a light-cured resin were eluted with culture medium for 1, 3, and 5 days. Cytotoxicity was judged using tetrazolium bromide reduction assay. RESULTS: The eluates from self-cured, heat-cured, and light-cured denture base resins were cytotoxic to primary human buccal fibroblast cultures and KB cells. Self-cured resin was the most toxic denture base material among the chemicals tested in all cultures. The cytotoxicity decreased in the order of self-cured resin > heat-cured resin > light-cured resin for KB cells. The rank for buccal fibroblast cells was self-cured resin > heat-cured resin > light-cured resin. CONCLUSION: The influence of the cytotoxicity depended on the materials tested and the cell culture system used. The use of both permanent and primary cells is recommended for a better screening of the cytotoxic effects of denture base resins.

Acrylic Resins↗

The role of residual monomer in PMMA powder and methods of polymerization in the finding of residual monomer in poly(methylmethacrylate) denture base.

The amount of residual monomer in methylmethacrylate resins used for denture bases is directly dependent on the polymerization procedure chosen. Residual monomer in PMMA powder has not yet been fully clarified. The aim of this study was to determine the amount of residual monomer in some PMMA powders used for denture bases. The study included determination of the amount of residual monomer in specimens polymerized by various methods of polymerization, attempting to test the interrelationship between the finding of residual monomer in PMMA powder and the respective group of heath-cured resin specimens. Materials from the group of poly(methylmethacrylate) resins type I, class 1 (1--Biocryl R, Galenika, Belgrade-Zemun, and 2--Major Base R, Major Dental Industry, Torino) were used in the study. Experimental specimens were divided into two groups: (1) original PMMA powders; and (2) polymerized specimens obtained by two short curing cycles (a--fractional, classical, heterogeneous polymerization; b--using the Prestherm, Bego device) and three long-curing cycles of polymerization (a--14 h at 70 degrees C; b--7 h at 70 degrees C and 3 h at 100 degrees C; and c--14 h at 70 degrees C and 3 h at 100 degrees C). By 2 g of each powder/specimen were extracted with methanol for residual monomer to be demonstrated by a modified method of gas chromatography on a device manufactured by Perkin Elmer Co. (Norwalk, Conn., USA). Original PMMA powders contained a high but varying percentage of residual monomer. Polymerized specimens had significantly lower values of residual monomer as compared to PMMA powders.(ABSTRACT TRUNCATED AT 250 WORDS)

Denture Bases↗

[Bending behavior of superplastic titanium alloy for denture base].

The mechanical behavior of the Ti-6A1 4V alloy denture base made by superplastic forming was studied using various bending tests. The bending strength of the Ti-6A1-4V alloy plate made by superplastic forming was as strong as that of the casting Co-Cr alloy plate with the same thickness. The bending strength of the superplastic forming plate with channels was higher than that of the plain plate. Increase in the arch curvature of the plate decreased the strength, because increase in the arch curvature of the plate decreased the thickness of the superplastic forming plate. Similar results were obtained for the clinical models. The appropriate original thickness for superplastic forming denture base was derived empirically from the experimental values for depth of palate.

Chromium Alloys↗

Improving the adaptation of denture bases by anchorage to the casts: a comparative study.

The purpose of this study was to investigate the adaptation of complete maxillary dentures to stone casts processed by the conventional, and two anchoring, methods. The anchoring methods used holes drilled on the cast and a special flange extended onto the posterior aspect of the maxillary cast. Both anchoring methods improved the adaptation of denture bases by minimizing the discrepancy between the denture base and cast. The greatest discrepancies observed in all methods were at the central portion of the posterior border.

Denture Bases↗

An in vitro study into the effect of a limited range of denture cleaners on surface roughness and removal of Candida albicans from conventional heat-cured acrylic resin denture base material.

This study evaluated the abrasiveness of four denture cleaners on the surface of denture base material and assessed their ability to remove Candida albicans. Acrylic resin discs 20 mm diameter and 2 mm thick were identically produced and polished. Four cleaners were evaluated: conventional toothpaste; toothpaste with stain remover; denture cleaning paste and an immersion type cleaner, and water were used as control. These were used at dilutions of 1:1, 1:2 and 1:3 with water. An electric toothbrush was used, and the discs cleaned to simulate 1 years' cleaning. The surface roughness of the discs were then measured, before and after cleaning, using a stylus profilometer, then inoculated with 1.2 x 10(6)C. albicans cells. The effectiveness of the denture cleaners to remove C. albicans cells was assessed following a single cleaning event. The immersion cleaner was significantly less abrasive than paste cleaners (P < 0.05). There were no significant differences between any dilutions for any cleaner used (P > 0.05). Immersion and paste cleaners removed almost all recoverable C. albicans from the discs, as cleaning with water alone was less effective (P < 0.05). An immersion type cleaner was found to be the most suitable cleaner because of its low abrasivity and effective removal of organic debris.

Acrylic Resins↗

Effects of chemical disinfectants on the transverse strength of denture base acrylic resins.

The disinfection of dental prostheses by immersion in a chemical solution should be capable of rapid inactivation of pathogenic microorganisms, without causing any adverse effect on the denture base resins. This study evaluated the effect of disinfection immersion on the transverse strength of two heat-cured resins. The denture base resins (Lucitone 550 and QC 20) were polymerized according to the manufacturers' instructions. After polymerization, the specimens were polished, and then stored in water at 37 degrees C for 50 +/- 2 h prior immersion in one of the following solutions for 10 min: 4% chlorhexidine, 1% sodium hypochlorite and 3.78% sodium perborate. The specimens were submitted to disinfection twice, simulating when dentures come from the patient and before being returned to the patient. Ten specimens were made for each group. The transverse strength was evaluated by a 3-point bend test. The flexural strength of the two denture base acrylic resins evaluated remained unaffected after immersion in the three solutions evaluated. In general, the QC 20 resin specimens exhibited lower transverse strength than the Lucitone 550 resin specimens, regardless of immersion solutions.

Acrylic Resins↗

The effect of the mandibular buccal denture base surface on food retention.

The accumulation of food debris in the buccal vestibule surrounding a mandibular denture flange was studied. This investigation focused on the effect of the thickness, physiologic molding, and slope of the buccal flange of denture base on the patient's ability to expel test-food particles from the area. Experimental denture bases were placed in the mandibular buccal vestibule of subjects having a complete natural dentition. Only the slope of the polished surface of buccal flange was found to have a significant positive correlation with the ability to expel test food from the buccal vestibule.

Adult↗