Clinical applications of ultrathin flexible bronchoscopes.

Three different models of ultrathin flexible fiberoptic bronchoscopes (1.8, 2.3, and 2.7 mm in diameter) were used in 190 examinations of pediatric patients. These instruments facilitate clinical procedures and evaluations that are difficult if not impossible with previous bronchoscopes. New applications include endoscopic transnasal intubation with endotracheal tubes as small as 3.0 mm (ID), inspection of the upper lobe segments in infants weighing less than 2.5 kg, and evaluation of the lower airways through endotracheal tubes as small as 2.5 mm (ID) or tracheostomy tubes as small as no. 00 (3.1 mm ID). Although these instruments have no suction channel and are thus incapable of removing airway secretions or obtaining specimens, they are extremely useful for many clinical purposes in infants and young children.

Bronchoscopes↗

The ultra-thin bronchoscope in management of the difficult paediatric airway.

The use of an ultra-thin flexible fiberoptic bronchoscope with a single lumen diameter of 2.7 mm at the distal tip to assist intubation of paediatric patients with a difficult airway is reported. Two patients (ages 30 months and 18 months) with mandibular hypoplasia and one patient (three months) with the Pierre-Robin syndrome are reported. In each case two fiberoptic bronchoscopes were used. The first allowed introduction of topical local anaesthetic while the second and smaller one was used for tube placement.

Anesthesia, Local↗

Audit of bronchoscope disinfection: a survey of procedures in England and Wales and incidents of mycobacterial contamination.

Procedures used for cleaning/disinfection of fibreoptic bronchoscopes and incidents of mycobacterial contamination were assessed by postal questionnaire. Information supplied by the Infection Control Doctor in 129 of 198 hospitals (65.2%) was used to audit local practice for compliance with national guidelines. Discrepancies between recommended and local practice included lack of specification of detergent/cleaning agent (57%), inadequate contact time for chemical disinfection (40%) and the use of tap water rather than sterile water for rinsing the disinfected bronchoscope (39.7%). Other procedural anomalies associated with mycobacterial contamination included failure to adhere to manufacturers' instructions to dismantle valves prior to cleaning and to autoclave valves/accessories. The association of mycobacterial incidents with the use of automatic washer/disinfectors (17 of 18 incidents) together with Department of Health warnings of build-up of biofilm within these chemical-process machines gives further cause for concern.

Bronchoscopes↗

Antibiotic susceptibility of glutaraldehyde-tolerant Mycobacterium chelonae from bronchoscope washing machines.

BACKGROUND: Contamination of bronchoalveolar lavage fluid is a major problem in the world. Although 2% glutaraldehyde (GA) is widely used as a disinfectant for bronchoscope cleaning, recently, GA-tolerant mycobacteria have been isolated, which makes this problem more complicated. METHODS: We studied the susceptibility to GA and antibiotics of mycobacteria isolated from bronchoscope washing machines in our hospital. We also studied the minimum inhibitory concentrations of GA and antibiotics with pump inhibitors. RESULTS: Twenty-nine mycobacteria were isolated, of which 26 were Mycobacterium chelonae. Among 18 isolates of M chelonae, excluding 8 isolates in which some results were not reproducible, 50% (9 of 18) were 2% GA-tolerant. One hundred percent (9 of 9) of the GA-tolerant isolates and 11% (1 of 9) of the GA-sensitive isolates were either resistant or intermediately resistant to 2 or 3 classes of antibiotics. Efflux pump inhibitors did not influence the susceptibility to GA and antibiotics. CONCLUSIONS: It was suggested that there might be an association of GA tolerance with antibiotic resistance in M chelonae. There may a different mechanism(s) other than that involving efflux pumps with regard to GA tolerance and antibiotic resistance in M chelonae. When bronchoscopy-related mycobacterial infections are suspected, physicians and clinical microbiologists should exercise care in handling GA-tolerant mycobacteria, which may be resistant to multiple antibiotics.

Anti-Bacterial Agents↗

Nosocomial outbreak of Pseudomonas aeruginosa infections related to a flexible bronchoscope.

An outbreak of Pseudomonas aeruginosa infections affecting 17 patients was detected in the 27-bed intensive care unit (ICU) of a community hospital from 1 July to 30 September 2003. An ambidirectional cohort study was conducted to identify the risk factors for infection. Nosocomial infections were defined using the criteria of the Centers for Disease Control and Prevention. Random arbitrary polymorphic DNA-polymerase chain reaction was used for genotypic characterization. Logistic regression analyses demonstrated that case patients were more likely than non-cases to have had a longer stay in the ICU, and to have undergone mechanical ventilation and antimicrobial treatment. The multi-variate analysis identified recent bronchoscopy [risk ratio (RR) 3.8, 95% confidence interval (CI) 2.5-3.9] and exposure to an infected patient (RR 2.9, 95% CI 1.1-3.7) as independent risk factors. Molecular analysis showed that of the nine isolates available, four patients had a similar strain. The factor with the strongest influence on the risk of death was infection with P. aeruginosa (RR 2.1, 95% CI 1.0-2.4, P=0.04). A combined infection control strategy was implemented, including strict compliance with isolation precautions and recommendations for cleaning and disinfecting bronchoscopes, and a sharp reduction in the incidence of P. aeruginosa infection followed. It is thought that this outbreak was caused by patient-to-patient transmission and infection from a common source, i.e. the flexible bronchoscope.

Bronchoscopes↗

Experience with removing Palmaz stents with a rigid bronchoscope.

BACKGROUND: The Palmaz stent can relieve congenital malacia or stenosis of airway, but reports on the indications and results of stent removal are rare. The authors report their experience in removing Palmaz stents and discuss the indications for removal. METHODS: Thirteen stents in 12 patients were removed by a rigid bronchoscope for various reasons. The indications were expected recovery (n = 5), severe granulations and expected recovery (n = 2), stent collapse (n = 2), and stent migration and/or fracture (n = 4). RESULTS: The course after removal was smooth in 9 patients and complicated in 3. The indications for stent removal in these 3 complicated cases were all expected recovery. One of the 3 complicated cases needed emergent cardiopulmonary bypass and tracheostomy for a collapsed stent that occluded airway, 1 failed for intractable bleeding, and 1 failed for intense vagal reflex causing cardiac arrest. At 6 months of follow-up, satisfactory results were seen in all but one case that needed further procedures for an iatrogenic tracheoesophageal fistula. CONCLUSIONS: Most Palmaz stents can be removed smoothly with a rigid bronchoscope; however, lethal complications can happen. The authors suggest that indications for stent removal should be intractable airway symptoms caused by the stent rather than expected recovery. Muscle relaxants should be avoided during anesthesia to maintain spontaneous breathing, and cardiopulmonary bypass should be on standby.

Bronchoscopes↗

In-use evaluation of Perasafe compared with Cidex in fibreoptic bronchoscope disinfection.

The mycobactericidal activity of Perasafe (0.26% peracetic acid) was compared with that of Cidex (2% alkaline glutaraldehyde) by an in-use test. Fibreoptic bronchoscopes were artificially contaminated with Mycobacterium tuberculosis or Mycobacterium avium-intracellulare in sputum and, after manual pre-cleaning with a neutral soap, 10 and 20 min disinfection periods were tested. Perasafe was as effective as Cidex, thus requiring a 10 min disinfection period against M. tuberculosis and 20 min against M. avium-intracellulare. The results demonstrate that Perasafe is an effective disinfectant for use in reprocessing fibreoptic bronchoscopes.

Bronchoscopes↗

Mycobacterium gordonae in fiberoptic bronchoscopes.

BACKGROUND: Failure of high-level disinfection of bronchoscopes has caused several outbreaks of nosocomial infection or pseudoinfection involving mycobacteria. METHODS: Inocula (10(5) colony-forming units/ml and 10(8) colony-forming units/ml) of a clinical Mycobacterium gordonae isolate were used to contaminate bronchoscopes. Glutaraldehyde, iodophor, and peracetic acid disinfectants were evaluated in manual and automated disinfection procedures after 10- to 20-minute exposures at 20 degrees and > or = 25 degrees C. RESULTS: Four of five manual disinfectant procedures failed to eliminate experimental M. gordonae infection after 10-minute exposure at 20 degrees C. All five manual procedures tested at 20 degrees C were effective after 20-minute exposure to the five disinfectants (two 2% alkaline glutaraldehyde preparations, 3.2% alkaline glutaraldehyde, 75 ppm iodophor, and 0.5% glutaraldehyde-0.03% phenolic). Three of four manual (one 2% glutaraldehyde, 3.2% glutaraldehyde, and 0.5% glutaraldehyde-0.03% phenolic) and three automated (one 2% glutaraldehyde, 0.5% glutaraldehyde-0.03% phenolic, and 0.2% peracetic acid) disinfectant procedures eliminated contamination after a 10- to 12-minute exposure at > or = 25 degrees C. Effective total cycle times for the three automated procedures ranged from 20 to 45 minutes. CONCLUSIONS: Previously Environmental Protection Agency-approved tuberculocidal agents may be ineffective against M. gordonae when used according to label claims under normal clinical conditions. A minimum 20-minute exposure time at 20 degrees C is necessary for manual disinfection methods. Higher temperatures may improve disinfectant efficacy. Newer automatic disinfection machines may be as effective as traditional manual methods and also may reduce hazards to employees.

Bronchoscopes↗

Comparison of a solution of super-oxidized water (Sterilox) with glutaraldehyde for the disinfection of bronchoscopes, contaminated.

The efficacy of Sterilox, a super-oxidized water holding a reduction/oxidation potential of greater than 950 mV was compared with the efficacy of glutaraldehyde against clinical isolates of Mycobacterium tuberculosis and Mycobacterium avium-intracellulare. An in use method using an automated bronchoscope washing machine demonstrated that over five cycles, Sterilox with a contact time of 5 min gave log10 reduction factors for M. tuberculosis and M. avium-intracellulare of >6 and >5, respectively. Glutaraldehyde with a contact time of 10 min gave log10 reduction factors for both M. tuberculosis and M. avium-intracellulare of >4, and at a contact time of 20 min >5 each. The non-toxic nature of Sterilox, together with the reduction in viable counts demonstrated in this study, suggest that the solution is an effective alternative mycobactericidal agent to the established disinfectants for the disinfection of bronchoscopes and, therefore, justifies further investigation.

Bronchoscopes↗

An outbreak of multidrug-resistant Pseudomonas aeruginosa infection associated with contamination of bronchoscopes and an endoscope washer-disinfector.

Over a two-month period, two distinct types of Pseudomonas aeruginosa resistant to ceftazidime and azlocillin were isolated from bronchial specimens of ITU patients who had been previously bronchoscoped. The source of the outbreak was probably a faulty contaminated bronchoscope washer-disinfector which had been purchased a year earlier but not properly maintained. This paper describes the outbreak, the identification and elimination of the source, and the steps taken to prevent recurrence. Several automated, closed washer-disinfectors had been bought by the hospital in response to health and safety concerns about glutaraldehyde disinfection toxicity, but the operation and maintenance of these machines had not been supervised. Several other washer-disinfectors were also found to be faulty. The potential hazards of automated endoscope washer-disinfectors and the importance of controlled professional maintenance, servicing and training is discussed.

Azlocillin↗

[Nasotracheal intubation with laryngeal mask and fiber bronchoscope].

An alternative way to the usual mode of nasotracheal intubation is described. 50 patients had to be intubated nasotracheally for surgical procedures. After induction of anaesthesia and insertion of the laryngeal mask a fiberoptic bronchoscope was nasally inserted during sufficient breathing. After view of the laryngeal mask, it was taken out and a tube via fiberoptic bronchoscope was placed endotracheally. Way and avoidance of complications by this method are described.

Bronchoscopes↗

Easy removal of a large mucus plug with a flexible paediatric bronchoscope after administration of rhDNase (Pulmozyme).

Mucoid impaction and plastic bronchitis are relatively rare disorders affecting patients of any age. Here we report the case of mucoid impaction developing in a four-year-old child as a complication of pneumonic infection treated four weeks prior. p.a. chest X-ray and fiberoptic bronchoscopy showed atelectasis and the location of a mucus cast in the left upper lobe. After extraction of the cast via the suction channel of the bronchoscope had failed, we administered 2.5 mg of undiluted recombinant human deoxyribonuclease (rhDNase) instilled directly over the affected area of occlusion for 15 minutes. This mucolytic agent mobilized the cast by reducing viscoelasticity and adherence of mucus. Subsequent extraction of the mucus cast was easy, resulting in immediate reduction of atelectasis and discharge of the child the following day. Treatment of severe mucus plugging by direct instillation of rhDNase has been a safe and efficacious procedure for mobilising adherent mucus plugs and for facilitating bronchoscopic extraction.

Bronchitis↗

Flexible fiberoptic bronchoscopy and laryngoscopy in children under 2 years of age: diagnostic and therapeutic applications of a new pediatric flexible fiberoptic bronchoscope.

The new flexible fiberoptic bronchoscope (Olympus BF Type 3C4, Tokyo, Japan) was employed for diagnostic and therapeutic purposes in 96 children below 2 yr of age. Sixty-two laryngoscopies and 34 bronchoscopies were performed without any mortality or significant morbidity. The bronchoscope was helpful in establishing diagnosis and also served as a tool for aspirating secretions and resolving atelectasis. It is concluded that flexible fiberoptic bronchoscopy and laryngoscopy in children 2 yr or younger is a safe procedure and may aid in the diagnosis and therapy of disorders of the respiratory tract in this age group.

Bronchoscopes↗

Montgomery T-tube insertion using a rigid bronchoscope under direct observation.

The Montgomery T-tube (T-tube) is an effective device for relieving tracheal stenosis when lesions are inappropriate for surgical reconstruction. Several techniques have been developed for the insertion of the T-tube in difficult conditions. The aim of this study was to present our experience using a rigid bronchoscope for T-tube insertion. A retrospective chart review of patients with tracheal stenosis who underwent T-tube insertion between April 2002 and July 2005 was conducted. Thirty-seven patients underwent 53 T-tube placements. Successful stent placement was achieved in all 37 patients. The T-tube was not tolerated in six patients because of granulation obstruction of the upper limb or sputum impaction. Thirty-one patients had good long-term results and enjoy adequate airway with the T-tube. There was no procedure-related mortality and there were no complications. Rigid bronchoscopic insertion of the T-tube for tracheal stenosis is a safe and an effective procedure. It ensures the correct placement of the T-tube when the technique described by Montgomery fails.

Bronchoscopes↗

Thoracoscopy: assessment of a physician service and comparison of a flexible bronchoscope used as a thoracoscope with a rigid thoracoscope.

The practicality of physicians performing thoracoscopy for diagnostic purposes was assessed in 30 patients with pleural effusions of unknown cause. A rigid thoracoscope was compared with a fibreoptic bronchoscope used as a flexible thoracoscope and the diagnostic adequacy of biopsy specimens obtained with the two instruments assessed. The two instruments were inserted by a physician in the bronchoscopy suite using local anaesthesia. The procedure proved safe, acceptable, and diagnostically effective. The rigid thoracoscope proved a more satisfactory instrument but the fibreoptic bronchoscope, with minor adaptations, may be used for thoracoscopy.

Biopsy↗

Methodological aspects of bronchoscopic lung volume reduction with a proprietary system.

Bronchoscopic lung volume reduction (BLVR) is emerging as a new technique to palliate symptoms in patients with severe emphysema. Several devices and techniques are being developed to occlude airways resulting in collapse and reduced lung volume. Here we present in detail the methodological aspects of one such interventional bronchoscopic approach.

Anesthesia, General↗

Neodymium:YAG laser fiber steering device for carbon dioxide laser rigid bronchoscope set.

A steering device for the Nd:YAG laser fiber to be used in conjunction with the rigid carbon dioxide laser bronchoscope set has been designed. This device inserts into the proximal end of the rigid bronchoscope and has the ability to accept a rigid optical telescope and the Nd:YAG laser fiber, and to evacuate smoke from the operative field.

Bronchoscopes↗