Pharmacokinetic applications of capillary electrophoresis.

This review briefly discusses the use of capillary electrophoretic (CE) methods for the investigations of different aspects of pharmacokinetics. In most investigations, CE was the method of choice because of its unique features, including high resolving power for chiral or metabolite separation, small sample volume for pediatric pharmacokinetics or for cell-based investigations, in situ microdialysis sampling for rapid eliminations, low UV wavelength detection for nonderivatized analytes, fast and simplified sample processing for existing methods that require tedious sample preparation, or as a second method for verifications. Moreover, instrumental aspects of CE-based assays for pharmacokinetic studies, such as different modes of CE methods for analyzing biological samples, sample stacking for increasing detection sensitivity, and coupling techniques with microdialysis and mass spectrometry, are also discussed in this review. Furthermore, the advantages and limitations of CE methods as well as the future outlook for pharmacokinetic studies are summarized.

Animals↗

Search on ruggedness of fast gas chromatography-mass spectrometry in pesticide residues analysis.

In this study, suitability of fast gas chromatography-mass spectrometry (GC-MS) on a narrow-bore column with a programmed temperature vaporizer for the analysis of pesticide residues in non-fatty food was evaluated. The main objectives were ruggedness and stability of chromatographic system with regards to co-extractives injected. The chromatographic matrix induced response enhancement was found to be strongly dependent on the concentration of residues and is reaching up to 700% compared to the pesticides solutions in a neat solvent. However, the responses of pesticides in matrix-matched standards at different concentration levels do not significantly change during 130 injections. Response enhancement/or decrease is influenced by the sample preparation technique. External calibration with matrix-matched calibration standards should, therefore, provide results with good precision also at the concentration level of 0.005 mg kg(-1). Special attention is given to the performance of the chromatographic column and retention gap with regards to peak widths, peak tailing and different sample preparation methods. During approximately 460 matrix sample injections, the performance of the analytical column was acceptable. GC-MS set-up with 0.15 mm i.d. column can be successfully utilized for the pesticide residues analysis.

Food Analysis↗

High-performance liquid chromatography profiling of the major carotenoids in Arabidopsis thaliana leaf tissue.

Carotenoids are extremely sensitive to a variety of physico-chemical attacks which may have a profound effect on their characteristic properties, thereby influencing the accurate identification and quantification of individual compounds. In this light, a comprehensive summary of the pitfalls encountered and precautions to be administered during handling and storage of authentic standards and samples was found to be incomplete. Furthermore, acceptable baseline separation of trans-lutein from trans-zeaxanthin and between the cis- and trans-forms of neoxanthin and violaxanthin has not been satisfactorily demonstrated. Hence the most optimal sample preparation and analytical steps were determined and a sensitive and reproducible method for the quantitative HPLC profiling of the principal carotenoids found in plant leaf tissue was developed. A reverse-phase C(30) column with a binary mobile solvent system was used for the baseline separation of eight of the major carotenoids and the two chlorophylls (a and b) within 18min. These compounds were identified via the use of authentic standards, their spectral characteristics and HPLC-atmospheric pressure chemical ionization (APCI)-mass spectrometry (MS) confirmation. This method has been successfully applied for the quantification of plant pigments in Arabidopsis thaliana wild-type (WT) leaf tissue and in two A. thaliana non-photochemical mutants, namely npq1 and npq2. These mutants have previously been well-characterised and provided valuable reference data as well as acting as internal controls for the assessment of our new method.

Arabidopsis↗

Evaluation of online extraction/mass spectrometry for in vivo cassette analysis.

An online extraction/mass spectrometry technique was evaluated for direct analysis of plasma samples. A simple user-friendly online extraction system that consists of two pumps, an autosampler, a six-port switching valve and a mass spectrometer is described. The system was controlled by the LC-MS software (Masslynx 3.5, Waters Corporation, Beverly, MA). Various analytical conditions such as extraction column, mobile phases, run time and wash solvent were optimized to establish an analytical method that was simple, easy to set up and generic. Sample preparation effort was minimal, which included dilution of plasma with water and centrifugation conducted in 96-well plate format. The system was used to analyze in vivo plasma samples from rat n-in-one cassette dosing studies. Concentration and pharmacokinetic (PK) data obtained from the online extraction method were comparable with data obtained from the protein precipitation extraction method. Overall, the simple, robust online extraction system provides cost savings by minimizing sample preparation and method development time. The system was used to analyze compounds from different structural classes. These studies suggest that calculated lipophilicity of a compound can be used as a tool for pre-selection of extraction column, which would save method development time for early discovery studies.

Animals↗

Immuno-affinity solid-phase extraction.

The measurement of trace organics such as drugs and pesticides at low concentration in biological and environmental samples is a challenging analytical task. Despite recent advances in instrumentation most analysts regard sample preparation as the rate-limiting step in the overall analytical method. In recent years there has been a lot of interest in immobilising antibodies onto solid supports such as silica to provide highly selective solid-phase extraction. This paper reviews the use of immuno-affinity for solid-phase extraction. It uses as examples extraction of chlortoluron and isoproturon from water and morphine and clenbuterol in urine and plasma respectively. An extensive list of other examples is given. Optimisation procedures are discussed in detail.

Chromatography, Affinity↗

Electron density imaging of protein films on gold-particle surfaces with transmission electron microscopy.

BACKGROUND: Surface bound proteins on colloid particles are widely used in biotechnological applications such as diagnostics or separation. Analysis of colloid surfaces by imaging methods provides information on the structure of these protein films, and an understanding of the functional relationships of biomolecules immobilised on solid surfaces. METHODS: In order to visualise protein molecules organised in films on surfaces of nano-sized gold-particles, an electron-microscopic approach based on the scattering absorption contrast of the specimen was applied. RESULTS: Analysing protein conjugated gold particles with a transmission electron microscope, protein films on gold particle surfaces cause a significant scattering absorption contrast based on the materials' electron density. Thus, the thickness of such films becomes directly measurable in planar projection and the shape of these films are visualised without negative staining methods. The insertion of Ruthenium-labelled antibodies instead of non-labelled antibodies as a marker with increased electron-density in these films yields a contrast enhancement of the whole film. Additional labelling with anti-Mouse IgG Gold conjugates localises the position of the surface bound antibodies in such protein films. CONCLUSIONS: The power of transmission electron microscopy to resolve protein-films on colloid surfaces without staining or labelling as a sample preparation procedure has been demonstrated. Thus, this direct method provides an analytical tool for studying protein films and their structural features on particle surfaces.

Animals↗

The investigation and the use of high flow column-switching LC/MS/MS as a high-throughput approach for direct plasma sample analysis of single and multiple components in pharmacokinetic studies.

Recently direct plasma injection LC/MS/MS technique has been increasingly used in pharmaceutical research and development due to the demand for higher throughput of sample analyses. In this work, two on-line extraction methods including high flow LC/MS/MS and high flow column switching LC/MS/MS were investigated. The evaluations were conducted and focused on their performances with respect to peak responses, separation efficiency, and signal to-noise ratio in a multiple-component LC/MS/MS assay. Two HPLC pumps were used-with one for high flow delivery and one for gradient elution. A CTC autosampler was used to inject plasma samples. High flow LC was achieved by the use of 4 ml/min flow rate on a 1 x 50 mm Waters Oasis column. A 2 x 100 mm YMC column was coupled via a column-switching valve. The extracted analytes were analyzed in multiple-reaction-monitoring (MRM) mode using a triple quadrupole MS/MS. As a rapid and simple procedure, vortex-mixing plasma and internal standard directly in sample vials completed sample preparation. The high flow column switching method (two-column system) provided sharper peak shape than the conventional high flow method. This effect increased analyte signal-to-noise ratio and sensitivity. Narrower peak width resulted in much better separation efficiency, which was required for multiple compound (N-in-1) analysis. A 2 mm I.D. column resulted in better peak shape and resolution than using a smaller I.D. column. The selected method achieved acceptable recoveries for most of the compounds tested, and it was successfully applied to a 10-in-1 pharmacokinetic (PK) study. The results showed that the dynamic range, lower limit of quantitation, assay accuracy and precision were acceptable for all compounds. Rapid sample preparation eliminated labor intensive and time consuming processes and improved productivity. This high throughput on-line extraction high flow column switching method has been proven particularly useful for multiple component analysis in PK studies.

Chromatography, Liquid↗

Two-dimensional conformation-dependent electrophoresis (2D-CDE) to separate DNA fragments containing unmatched bulge from complex DNA samples.

DNA fragments containing mispaired and modified bases, bulges, lesions and specific sequences have altered conformation. Methods for separating complex samples of DNA fragments based on conformation but independent of length have many applications, including (i) separation of mismatched or unmatched DNA fragments from those perfectly matched; (ii) simultaneous, diagnostic, mismatch scanning of multiple fragments; (iii) isolation of damaged DNA fragments from undamaged fragments; and (iv) estimation of reannealing efficiency of complex DNA samples. We developed a two-dimensional conformation-dependent electrophoresis (2D-CDE) method for separating DNA fragments based on length and conformation in the first dimension and only on length in the second dimension. Differences in migration velocity due to conformation were minimized during second dimension electrophoresis by introducing an intercalator. To test the method, we constructed 298 bp DNA fragments containing cytosine bulges ranging from 1 to 5 nt. Bulge-containing DNA fragments had reduced migration velocity in the first dimension due to altered conformation. After 2D-CDE, bulge-containing DNA fragments had migrated in front of an arc comprising heterogeneous fragments with regular conformation. This simple and robust method could be used in both analytical and preparative applications involving complex DNA samples.

Cytosine↗

Determination of methyldopa in plasma using high-performance liquid chromatography with electrochemical detection. Application to pharmacokinetic/bioavailability studies.

The problem of quantitatively measuring methyldopa (a-methyldopa) in biological matrices after applying therapeutic doses to humans is still challenging. Numerous methods have been published but most of them require a tedious, time-consuming sample preparation, are not specific enough or lack the necessary sensitivity. As the basis of conclusive human pharmacokinetic and bioavailability/bioequivalence studies is a validated analytical method, which is reliable, selective, sensitive and able to proceed hundreds or even thousands of samples in a limited time, an assay to fulfill these needs was developed. The present method employs a hiph-performance liquid chromatographic system consisting of a pump, an ODS column, an autosampler and an electrochemical detector. The assay is sensitive down to 50 ng/ml plasma, the calibration curves are linear in a range of 50-2000 ng/ml, the chromatographic peaks are well resolved and the precision and accuracy are excellent. The assay has been successfully used for the determination of very low methyldopa plasma levels during several clinical studies.

Biological Availability↗

Simultaneous determination of loratadine and desloratadine in pharmaceutical preparations using liquid chromatography with a microemulsion as eluent.

A rapid HPLC procedure for analytical quality control of pharmaceutical preparations containing the antihistaminic drug substance loratadine and/or its analog desloratadine (which is also an active metabolite of loratadine) was developed using a microemulsion as the eluent. The separation was performed on a column packed with cyanopropyl bonded stationary phase adopting UV detection at 247 nm using a flow rate of 1 ml/min. The optimized microemulsion mobile phase consisted of 0.1M sodium dodecyl sulphate, 1% octanol, 10% n-propanol and 0.3% triethylamine in 0.02 M phosphoric acid, pH 3.0. The developed method was validated in terms of specificity, linearity, lower limit of quantification, lower limit of detection, precision and accuracy. With the proposed method satisfactory resolution between loratadine and desloratadine (resolution factor=3.85). The method requires a minimum of sample handling and is rapid (10 min), and reproducible (R.S.D.<2.0%). The mean recoveries of the analytes in pharmaceutical preparations were in agreement with those obtained from a reference method, as revealed by statistical analysis of the obtained results using the Student's t-test and the variance ratio F-test. Pseudoephedrine, the co-formulated drug substance, did not interference with the assay and was successfully separated using the developed HPLC method.

Chromatography, Liquid↗

Quantification of bacterial lipopolysaccharides (endotoxin) by GC-MS determination of 3-hydroxy fatty acids.

A GC-MS method for the quantification of bacterial lipopolysaccharides (LPS, endotoxin) is presented. After hydrolytic cleavage of 3-hydroxy fatty acids (3-OH FAs) from the lipid A region of LPS, derivatisation of both the hydroxyl and the carboxyl group was performed in one step with a mixture of methyl-bis(trifluoracetamide)(MBTFA) and N-methyl-N-(tert-butyldimethylsilyl)trifluoracetamide (MTBSTFA). Using GC-MS in the EI mode with selected ion monitoring (SIM) for analysis, baseline separation of 3-OH FAs (and of possibly interfering 2-OH FAs) was achieved. The sensitivity of the method (LOD 7-50 pg/injection for the different 3-OH FAs investigated) allows for the efficient quantification of LPS in occupational and environmental samples. Degradation of 3-OH FAs as well as of their derivatives during sample preparation and GC-MS separation as a possible source of errors in analytical methods based on 3-OH FA determination is reported for the first time. Thermal elimination of water from the underivatised 3-OH FAs and of trifluoroacetic acid from the derivatives was identified as the cause of degradation. The resulting alpha,beta-unsaturated compounds showing the same mass spectra as the 3-OH FA derivatives were detected as more or less prominent satellite peaks. By using alkaline instead of acidic hydrolysis and cool on-column instead of split/splitless injection, elimination was reduced to an acceptable level.

Environmental Monitoring↗

Simultaneous quantitation of homocysteine, cysteine and methionine in plasma and urine by liquid chromatography-tandem mass spectrometry.

BACKGROUND: A method utilizing liquid chromatography-electrospray tandem mass spectrometry (LC-MS/MS) has been developed and evaluated for the determination of total homocysteine, cysteine and methionine in plasma and urine. The simultaneous measurement of homocysteine and methionine concentrations may help explain the underlying mechanism responsible for hyperhomo-cysteinaemia. METHODS: Samples were prepared by simple protein precipitation after reduction of disulphides by dithiothreitol. Reduced analyte signal caused by ionization suppression effects, seen with plasma samples, was compensated for with matrix-matched standards, and the use of isotopically labelled internal standards. Recovery for each analyte was better than 94%. RESULTS: Concentrations of plasma homocysteine determined by LC-MS/MS were compared with those obtained by two automated commercially available FDA-approved procedures: (i) high-performance liquid chromatography (HPLC) with pre-column derivatization and fluorescence detection and (ii) by fluorescence polarization immunoassay (FPIA). Agreement with the LC-MS/MS method is given by the Deming regression equations LC-MS/MS = 1.062 HPLC-0.01 and LC-MS/MS = 1.104 FPIA-0.43. CONCLUSION: Low reagent costs together with the relative simplicity of sample preparation make the LC-MS/MS method well suited, not only for research work but also in those laboratories with a tandem mass spectrometer, for the measurement of routine clinical samples.

Chromatography, High Pressure Liquid↗

Determination of ondansetron in plasma and its pharmacokinetics in the young and elderly.

Ondansetron is a 5-hydroxytryptamine3 receptor antagonist for the treatment of chemotherapy- and radiotherapy-induced nausea and emesis. A sensitive, accurate, and precise HPLC method for the determination of ondansetron in plasma is described. Samples are prepared by solid-phase extraction and, after chromatography of the extracts on a silica analytical column, ondansetron is detected by UV absorbance at 305 nm. The method is sensitive down to 1 ng/mL, at which concentration the coefficient of variation was 6.2% in a single assay run. Repeated analyses of quality control samples, nominally at 2 ng/mL, were carried out over a number of assay runs with a coefficient of variation of 5.5%. The method is specific for ondansetron with respect to endogenous plasma components, identified phase I metabolites, and some co-administered chemotherapeutic drugs. In sustained use over several months, and in support of the clinical development of ondansetron, the method has been shown to be robust. An application of the assay in the investigation of the pharmacokinetics of ondansetron in the young and elderly is described.

Adolescent↗

Method dependence of apparent stoichiometry in the binding of salicylate ion to human serum albumin: a comparison between equilibrium dialysis and fluorescence titration.

The binding of salicylate ion to human serum albumin (HSA) was studied in 100 mM potassium phosphate buffer (pH 7.4, 25 degrees C), using equilibrium dialysis and fluorescence titration methods. The protein samples tested were (a) dialyzed human plasma and (b) a commercial preparation of HSA, essentially free of globulin and fatty acids. Independent of the analytical method used, Scatchard and nonlinear regression analyses of the data pointed to a single class of high-affinity salicylate binding sites. On the other hand, the binding parameters were found to be method dependent. K(d) ranged between 25 +/- 2.4 and 62 +/- 15 microM in equilibrium dialysis and between 10 +/- 1.3 and 40 +/- 3.0 microM in fluorescence titration. (The higher limits refer to plasma samples at high [HSA]). Following the same pattern, the apparent stoichiometry of binding (though independent of sample identity and concentration) was higher in equilibrium dialysis (n(app) = 3.2 +/- 0.10) than in fluorescence titration (n(app) 1.9 +/- 0.30). The difference between the two methods could be reconciled by invoking two distinct classes of binding sites (I and II), which had identical (or marginally different) K(d) values, while differing in the magnitude of the fluorescence signal (Deltaf) generated upon ligand binding (Deltaf, PL(I) = Deltaf(I); Deltaf, PL(II) = 0). Further, it was assumed that the state of occupation of class II sites affected the fluorescence efficiency of class I sites, such that Deltaf, PL(I,II) = betaDeltaf(I) (beta = interaction factor). A random binding scheme involving P, PL(I), PL(II), and PL(I,II) was formulated. The model adequately predicted the behavior of the system when monitored through the change in protein fluorescence: Taking K(d) = 25 microM and n(T) = 3, the interaction factor beta was found to be 0.62 +/- 0.10. It was concluded that the correct parameters for the binding of salicylate ion to HSA are K(d) = 25 +/- 2.4 microM and n(T) = 3.2 +/- 0.10, as indicated by equilibrium dialysis of purified HSA. Besides updating information relating to the salicylate binding potential of HSA, this study serves to illustrate a likely complication in the study of protein-ligand interactions by fluorometric methods.

Chromatography, Gel↗

Quantitative determination of the extent of neutralization of carboxylic acid functionality in carbopol 974P NF by diffuse reflectance fourier transform infrared spectrometry using Kubelka-Munk function.

PURPOSE: The purpose of this study was to develop an analytical method for the quantitative determination of the extent of neutralization of the carboxylic acid function in Carbopol 974P NF using Diffuse Reflectance Fourier Transform Infrared Spectroscopy (DRIFT) with Kubelka-Munk function analysis. METHODS: Carbopol 974P NF is a high molecular weight, chemically crosslinked polymer of acrylic acid, that has the C=O stretching band of the unionized carboxylic acid function at 1695 cm(-1). The quantitative determination of the extent of neutralization of the carboxylic acid function in Carbopol 974P NF is based upon the asymmetrical C=O stretching of the carboxylate anion at 1570 cm(-1) measured by DRIFT spectroscopy. RESULTS: To overcome spectral differences arising from sample preparation (powders, granules and tablets) and in an effort to increase the precision of the analytical method, the following approaches were used: (1) an internal standard, (2) first derivative of the spectrum to eliminate the effect of baseline drift and (3) the ratio of the first derivative of the C=O stretch of the carboxylate anion peak (1570 cm(-1)) in the neutralized Carbopol 974P NF to that of the peak of the internal standard (866 cm(-1)). The above data treatment techniques proved to be superior to the usual methods of peak height or peak area. The calibration curve of the ratio of the first derivative (1570 cm(-1)/866 cm(-1)) was a linear function of the mass of sodium carboxylate over the range from 0.0% to 100.0% neutralization of the carboxylic acid function in Carbopol 974P NF (Fig. 1a). No particle size or sample preparation effects were noted within the experimental error. CONCLUSIONS: DRIFT spectroscopy using the Kubelka-Munk function is a powerful tool for the routine determination of the extent of neutralization of the carboxylic acid function in Carbopol 974P NF in complex pharmaceutical formulations.

Acrylates↗

High-performance liquid chromatography tandem mass spectrometry procedure with automated solid phase extraction sample preparation for the quantitative determination of paclitaxel (Taxol) in human plasma.

A sensitive, specific, accurate and reproducible analytical method was developed and validated for the quantitation of the anticancer agent paclitaxel in human plasma. This procedure is based on high performance liquid chromatography/ion spray-tandem mass spectrometry. This methodology is highly specific because a MS/MS technique (multiple reactant-ion monitoring, MRM) was used for both paclitaxel and its internal standard. The use of a fully automated solid phase extraction procedure, using a CN Sep-pak cartridge, to improve the detection limit and quantification limit of paclitaxel in human plasma samples, was evaluated. The method involves the addition of methyl-paclitaxel as internal standard (i.s.). The retention times of paclitaxel and the I.S. were 2.8 and 4.0 min., respectively. The assay was linear over the range 5 to 500 ng/mL, with a quantification limit of 5 ng/mL having a coefficient of variation (c.v.) < 10%. Standard calibration curves, performed on three different days, had correlation coefficients always greater than 0.998. The intra and inter-day precision were within 12%, and accuracy was included in the range 102-110%. Paclitaxel recovery assessed at 15,250 and 500 ng/mL, was determined to be greater than 85%. The assay is applicable to clinical pharmacokinetic studies.

Antineoplastic Agents, Phytogenic↗

Application of solvent microextraction in a single drop for the determination of new antifouling agents in waters.

A new, rapid microextraction technique termed solvent microextraction (SME) has been developed for the simultaneous determination of new generation antifouling agents, in water samples. Chlorothalonil, dichlofluanid and Sea nine 211 were employed as model compounds to asses the extraction procedure and were determined by gas chromatography with electron capture detection. Experimental parameters which control the performance of SME, such as selection of solvent, exposure time, agitation, organic drop volume, and salt concentration were optimized. The new method provided good average enrichment factors of >10.7 for all analytes, good precision (RSD < 8.5%) and good linearity (r2 > 0.9880). The limits of detection (LODs) were in the range of 0.00025-0.003 microg/L (S/N = 3). The SME was performed in different type of natural water samples and acceptable recoveries were obtained for the tested analytes. The results demonstrated that SME is a rapid, accurate and effective preparation method and could be successfully performed for the determination of antifouling agents in water samples.

Aniline Compounds↗