Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “diagnostic performance”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12Linked to original sources

Comparison of sensitometric and diagnostic performance of two films.

The sensitometric properties of Kodak Ektaspeed Plus and Flow E-speed film as well as their diagnostic efficacy for detecting proximal surface caries were compared. Flow and Kodak E-speed films were exposed and processed according to American National Standards Institute and American Dental Association (ADA) specifications, and film speed, contrast, and density of base plus fog were measured. Additionally, 80 premolar and molar teeth were imaged and their proximal surfaces scored by 12 dentists for the presence of caries. The actual depth of the caries was determined by microscopic examination of the teeth after sectioning. Kodak Ektaspeed Plus and Flow E-speed films, although labeled E-speed by the manufacturers, are both slow F-speed films. They have comparable base plus fog densities and comparable contrast curves. Dentists detected carious lesions equally well using both film types. The sensitivity, specificity, accuracy, and receiver operating characteristic area for detecting enamel and dentinal caries were not significantly different between the two films. Kodak Ektaspeed Plus and Flow E-speed films both meet or exceed the ADA performance specifications in terms of sensitometric properties. Both offer equal diagnostic utility for detecting caries.

Absorptiometry, Photon↗

Spectrophotometric assessment of pigmented skin lesions: methods and feature selection for evaluation of diagnostic performance.

This study documents the optical reflectance characteristics of pigmented skin lesions and evaluates their potential for improving the differential diagnosis of malignant melanoma from benign pigmented skin lesions. Optical reflectance spectra in the wavelength range 320-1100 nm were obtained from 121 lesions already selected by expert dermatologists as suspicious of malignancy. Characteristic differences in spectra from benign and malignant lesions were studied. Feature extraction showed significant differences between lesion groups classified by histology. Seven of the most relevant features were used in the discriminant analysis of reflectance spectra from 15 melanoma and 32 compound naevi which resulted in a sensitivity of 100% and specificity of 84.4% when compared with histology. This simple objective technique appears to perform as well as the expert dermatologist and may improve the diagnostic accuracy of non-specialists such as trainees and GPs. Further prospective clinical study of reflectance spectrophotometry in a larger patient group is now required.

Adolescent↗

[Diagnostic performance and usefulness of a research unit: prospective study].

An attempt was made to compare the diagnostic efficiency and overall usefulness (for the patient and for his primary care physician) of an investigation unit in internal medicine. 100 patients seen successively were studied. At the end of the investigation the patients were divided into 3 groups: (A) organic disease diagnosed (n = 44); (B) unexplained somatic complaint (n = 16); (C) unexplained functional complaint (n = 40). One year later, an inquiry about the patient's outcome was made by telephone to the patient and/or his physician. Follow-up of 99 patients did not disclose diagnostic errors in patients of groups A and C; in group B, 2 diagnoses were missed. The investigation was considered "useful" in 31 patients (disease cured or improved, patient reassured); 57% of primary-care physicians were aided despite a negative investigation.

Adolescent↗

The safety of performing diagnostic cardiac catheterizations in a mobile catheterization laboratory at primary care hospitals.

The benefits of mobile cardiac catheterization laboratories include keeping patients closer to their families, communities, local hospitals, and primary care physicians while receiving services comparable to those available at tertiary centers. However, there are very few studies regarding the safety of performing cardiac catheterization in mobile laboratories at remote locations. Thus, the authors performed an observational study of 1,775 consecutive patients undergoing a diagnostic cardiac catheterization in a mobile catheterization laboratory at primary care hospitals served by the Appleton Heart Institute (AHI) from August 1, 1991, to December 31, 1998. Twenty-three percent (1,775/7,637) of all AHI diagnostic cases in this time period were performed in the mobile catheterization laboratory. Urgent transfer to the tertiary care facility via ambulance or helicopter was used for 2.3% of patients (n = 41). The overall complication rate was 1.2% (n = 21). Of the patients who underwent cardiac catheterization in the mobile laboratory, 32.6% (n = 579) were subsequently referred for interventional or surgical revascularization. There were no deaths. Cardiac catheterizations can be performed safely in a mobile laboratory at primary care hospitals, provided that immediate transfer is available for those in need of urgent intervention or revascularization and that unstable patients are not studied in the mobile laboratory.

Adult↗

Diagnostic performance of enzymes in the discrimination of myocardial infarction.

We apply rigorous statistical methods to assess the diagnostic value of creatine kinase, creatine kinase-MB, aspartate aminotransferase, lactate dehydrogenase, and alpha-hydroxybutyrate dehydrogenase in realistic circumstances. The trade-off between false positives and false negatives obtained with various decision rules is examined with the receiver-operator characteristic function and with discriminant analysis. During the three days after an infarction, lactate and alpha-hydroxybutyrate dehydrogenase can provide diagnostic thresholds of constant sensitivity and specificity. By contrast, sensitivity progressively decays for creatine kinase, creatine kinase-MB, and aspartate aminotransferase. The diagnostic uncertainty introduced by the infarction's varying age at hospitalization is evaluated by subjecting the mixed patient population to discriminant analysis. For some enzymes, repeating the same assay on the second day contributes to sensitivity, while adding a different assay on the first day enhances specificity. The effects of lower or higher infarction prevalences on sensitivity and specificity are most favorable when creatine kinase-MB is combined with lactate or alpha-hydroxybutyrate dehydrogenase. Adding a third assay is ineffective. The further differentiation according to infarction stage produces only 81% correct classifications, even when five different assays are used on two consecutive days. As a general strategy, we recommend the assay of two enzymes on two consecutive days.

Aspartate Aminotransferases↗

Diagnostic performance of machine learning models versus established risk stratification for intracranial aneurysm rupture: a systematic review and bivariate meta-analysis.

BACKGROUND: Machine learning (ML) models have been proposed to improve the discrimination of intracranial aneurysm rupture status beyond established clinical risk stratification tools. However, reported performance is heterogeneous and the relative contribution of model architecture and feature dominance remains unclear. METHODS: We performed a Preferred Reporting Items for Systematic Reviews and Meta-Analyses-diagnostic test accuracy systematic review and diagnostic meta-analysis of studies evaluating ML models for intracranial aneurysm rupture discrimination. PubMed, Embase and CENTRAL were searched to February 2026. Sensitivity and specificity were pooled using a bivariate random-effects model, with summary receiver operating characteristic curves generated across training, internal testing and external validation datasets. Models were compared with regression-based approaches and Population, Hypertension, Age, Size of aneurysm, Earlier subarachnoid haemorrhage, Site of aneurysm (PHASES) scores. Subgroup and meta-regression analyses explored associations between algorithm family and feature domain. RESULTS: Sixty-two retrospective cohorts (29 709 patients 209 models) met the inclusion criteria. In training datasets, pooled sensitivity and specificity for ML were 0.81 (95% CI 0.75 to 0.85) and 0.83 (0.80-0.86), with an area under the curve (AUC) of 0.878, exceeding PHASES (AUC 0.667). In testing datasets, ML retained higher discrimination (AUC 0.837) than regression models (0.806) and PHASES (0.646). In external validation, sensitivity was preserved (0.82), but specificity declined (0.66). Deep learning demonstrated the highest AUCs (training and testing). Incorporation of haemodynamic or radiomic features improved pooled discrimination relative to morphology alone. Evidence of small-study effects and mostly unclear Prediction Model Risk Of Bias Assessment Tool ratings were observed. CONCLUSIONS: ML approaches demonstrate higher pooled discrimination for aneurysm rupture status than conventional risk scores in retrospective datasets, but reduced external validation specificity and heterogeneity limit confidence for clinical translation. Prospective, externally validated, calibrated models are required before integration into routine cerebrovascular risk stratification.

Humans↗

Diagnostic performance of 123I-labeled serum amyloid P component scintigraphy in patients with amyloidosis.

PURPOSE: To assess the diagnostic accuracy and additional information provided by 123I-labeled serum amyloid P component (SAP) scintigraphy in patients with systemic and localized amyloidosis. SUBJECTS AND METHODS: 123I-labeled human SAP was injected intravenously into 20 controls and 189 consecutive patients with histologically proven amyloidosis: of AA type in 60 cases, AL type in 80, hereditary ATTR type in 27, and localized amyloidosis in 22 cases. SAP scintigrams were obtained 24 hours after tracer injection and were analyzed for abnormal patterns of uptake. Sensitivity and specificity were determined, and scintigraphic findings were compared with clinical data. RESULTS: Diagnostic sensitivity of SAP scintigraphy for systemic AA, AL, and ATTR amyloidosis was 90%, 90%, and 48% respectively, and specificity was 93%. The distribution of amyloid was less diverse in AA than in AL type. Myocardial uptake was not visualized in any patient. Splenic amyloid was very frequent (80%) in AA and AL type but rarely detected clinically (14%). Abnormal tracer uptake in the liver and kidneys correlated with disturbed liver function and proteinuria, respectively. Bone marrow uptake was specific for AL (21%) and was more frequent in AL kappa than AL lambda. Localized amyloid deposits were not imaged. CONCLUSION: SAP scintigraphy is diagnostic of amyloid in most patients with AA and AL type but fewer with hereditary ATTR type, relating to differing distributions and burdens of amyloid in these disorders. It usually reveals more widespread organ involvement than is identified clinically, and certain distributions of amyloid are characteristic of particular fibril types.

Adult↗

Diagnostic performance of CT, MPR and 3DCT imaging in maxillofacial trauma.

CT imaging of complex maxillofacial fractures is common practice now, but the relative diagnostic value of spiral computed tomography (CT), multiplanar reformations (MPR), and three-dimensional (3D) reconstructions in evaluating maxillofacial fractures is not established with independent validation of correct diagnosis. We studied these modalities and measured their diagnostic value in a carefully controlled observer based rated response experiment. Multiple fractures were created by blunt experimental trauma in nine adult cadaver heads (five males, four females). Spiral CT scans were performed on all specimens before (control) and after trauma. Axial slices (CT), sagittal and coronal multiplanar reconstructions (MPR), and 3D volumetric reconstructions views were generated. Truth was determined by defleshing the specimens and direct inspection of the traumatized skull. Three expert readers separately interpreted CT, MPR and 3D film hard copy images presented in random order blinded to patient identification or experimental conditions. We measured the time to diagnose each case as recorded by a monitor who was present while evaluations were performed. Twenty-eight facial regions were evaluated using rated response and free response illustrative formats. Each region was considered separately. Sensitivity and specificity were calculated to measure observer performance. We found that 3D and CT had a similar performance in fracture detection and both were markedly better than MPR. For free response illustrative data, CT correctly identified 10% more orbital fractures than 3D, and approximately 10% fewer zygomatic fractures. Fracture localization was best with 3D. Reader confidence was highest with CT, but assessment time was faster with 3D. We conclude that CT and 3D are comparable in detecting midfacial fractures and both are superior to MPR. 3D reconstructions are superior for localization of complex fractures involving multiple planes.

Aged↗

Diagnostic performance of red cell sorbitol assay in a Nigerian teaching hospital.

The analytical linearity, detection limit, precision and accuracy, as well as diagnostic sensitivity, specificity and predictive values of red cell sorbitol (RCS) assay were evaluated using the fluorimetric enzymatic technique with the available laboratory facilities in a Nigerian Teaching Hospital. The assay was linear up to 40.0 nmol/ml. The detection limit was 0.55 nmol/ml. The within-assay coefficients of variation (CV) from low to high concentrations were in the range of 2.82% to 5.48% while the corresponding values for the between-assay variation were 3.60% to 6.05%. The mean recovery was 90.4%. High concentrations of some common blood constituents and drugs did not cause significant interference. An evaluation of the diagnostic sensitivity and specificity of RCS in 102 out-patients revealed a sensitivity of 94.4%, specificity of 98.8% and efficiency of 98.0%. The predictive value of a positive test was 94.4% while that of a negative test was 98.8%. The mean value of red cell sorbitol in patients confirmed to have diabetes mellitus (23.1 +/- 1.13 SE nmol/g Hb) was significantly higher (P < 0.001) than the corresponding value (11.0 +/- 0.0.27 SE nmol/g Hb) for those without diabetes and for control subject. A similar observation was also made for plasma glucose and fructosamine. These observations demonstrate that RCS assay could be adopted in a third world laboratory for clinical applications.

Adolescent↗

Performing diagnostic skin biopsies.

The Scope of Professional Practice states that nurses may respond to the needs of patients by expanding their practice. Performing skin biopsies for cancer diagnosis is one such area. The provision of appropriate education, training and updating is essential. Clear guidelines for practice are required for all such procedures.

Biopsy↗

Diagnostic performance of duplex ultrasonography in the detection of high grade internal carotid artery stenosis.

OBJECTIVES: to establish on a national basis whether the diagnostic accuracy of carotid duplex justifies carotid surgery without preoperative angiography. DESIGN: prospective national multicentre study with 10 participating university and county hospitals. MATERIAL AND METHODS: one hundred and thirty-four patients, aged 69+/-9 years, were subjected to routine carotid duplex ultrasonography and angiography. The influence of relevant factors on the relation between ultrasonographic and angiographic variables was evaluated using multiple regression analysis. The capacity of carotid ultrasonography to detect internal carotid artery (ICA) stenosis > or =80% was assessed by receiver operating characteristic analysis. RESULTS: the correlation between peak systolic velocity in ICA (PSV(ICA)) and the angiographic degree of stenosis was strong and significantly influenced only by the applied Doppler angle. Accordingly, the optimal PSV(ICA) cutpoint values for the diagnosis of ICA stenosis > or =80% (ECST method) differed substantially (2.1 and 3.2 m/s) between the two considered angle ranges (0-49 degrees and 50-62 degrees ), the ability to identify high grade ICA stenosis being significantly better at small Doppler angles (0-49 degrees ). CONCLUSION: ultrasonographic duplex technique identifies high grade ICA stenosis with a high degree of accuracy, which can be further improved by the application of small Doppler angles and the use of angle range specific PSV(ICA) cut-off points.

Aged↗

[Diagnostic performance of immunologic tests in amebic liver abscess using receiver operating characteristic curves].

Objectives. 1) To identify the tests of immunological diagnosis with a high diagnostic efficiency in amebic liver abscess. 2) To determine the ideal cutoff point for such tests. 3) To identify the influence degree of the antigen used over the test efficiency. Design. Comparative survey. Study units. Analysis of 24 articles identified in the medical literature about tests of immunological diagnosis in amebic liver abscess. Measurements. Starting from the articles, operating characteristics curves (ROC) were established derived from the test application to patients with amebic liver abscess. Results. A great variability in the diagnostic efficiency was identified between the various tests, even when the analysis was focused on the investigations of a specific test. It was not possible to conclude which test had a major degree of efficiency due to such variability. The cutoff level considered as relevant was higher than the one traditionally used for indirect hemagglutination and it had concordance with the one presently accepted for the fluorescence antibodies test. By maintaining steady the spectrum of the study patients and the type of test, variability among the tests persisted. This was due to the use of different antigens. Conclusions. A great variation in the diagnostic efficiency of the analyzed tests was identified. The variation source was the type of test, the antigen used and probably the illness spectrum.

Evaluation Studies as Topic↗

Diagnostic performance of complete lower limb venous ultrasound in patients with clinically suspected acute pulmonary embolism.

A limited ultrasound (US) confined to the popliteal and femoral veins is usually performed to detect deep vein thrombosis (DVT) in patients with clinically suspected acute pulmonary embolism (PE). Our objective was to assess the diagnostic accuracy of complete lower limb US examining both the proximal and distal veins in this setting. In this prospective study, 210 consecutive patients were included. Complete US was performed by independent operators and compared blindly with a reference strategy combining clinical probability, ventilation perfusion scan and pulmonary angiography to a three-month clinical follow-up. Simultaneously, VIDAS D-dimer (DD) assay and helical computed tomography (HCT) of the lungs were assessed independently and blindly. PE was present in 74 patients (35%). Complete US detected DVT in 91 patients (43%), proximal in 51 and distal in 40. Sensitivity and specificity with a 0.95 confidence interval were respectively 0.93 [0.85 - 0.97] and 0.84 [0.77 - 0.89]. Limited US detected DVT in only 46 patients (22%). Sensitivity and specificity were respectively 0.55 [0.44 - 0.66] and 0.96 [0.92 - 0.98]. For DD they were 0.92 [0.83 - 0.96] and 0.24 [0.17 - 0.32] and for HCT 0.84 [0.73 - 0.90] and 0.87 [0.80 - 0.92]. Complete lower limb US has higher sensitivity and capacity to exclude PE than limited US, but a slightly lower specificity. Complete US results also compared favourably with those of HCT and DD. The utility of including this method in diagnostic strategies for PE needs to be assessed in cost-effectiveness analysis and in outcome studies.

Angiography↗