At least 217 records · Page 12Linked to original sources

Enhanced biological stability of collagen porous scaffolds by using amino acids as novel cross-linking bridges.

Collagen porous scaffolds have been widely employed as a dermal equivalent to induce fibroblasts infiltration and dermal regeneration. To eliminate the disadvantageous drawback of the fast degradation speed, a cross-linking method was adopted by using a water-soluble carbodiimide, 1-ethyl-3-(3-dimethylaminopropyl)-carbodiimide (EDAC) and N-hydroxysuccinimide (NHS) in the presence of amino acids (glycin, glutamic acid or lysine), which function as cross-linking bridge between collagen molecular chains. In vitro assessment of the biological stability of the cross-linked collagen scaffolds found that the collagenase biodegradation degree was greatly decreased when lysine was added, resulting in a more biological stable scaffold. On the other hand, the biodegradation degree was accelerated compared with the purely cross-linked when glutamic acid was added, while less influenced by glycin addition. By comparing the biodegradation degree of the scaffolds added with amino acids and their model compounds, i.e. adipic acid and hexane diamine, the key factor influencing the biological stability was further investigated. The results indicated that the crucial factor is dependent on the ratio of amino groups to carboxyl groups in the cross-linking system. At optimal ratio the lowest biodegradation degree is achieved. Scanning electron microscopy measurements prove that the three-dimensional structure of the scaffolds was largely preserved. Preliminary in vitro culture of fibroblasts in the collagen scaffold cross-linked with EDAC/NHS in the presence of lysine has shown that the original good cytocompatibility of collagen was retained.

Amino Acids↗

Coils and tubes releasing heparin. Studies on a new vascular graft prototype.

Coiled metallic guidewires find widespread use, for instance in interventional cardiology. It is known that release of heparin from the surface of guidewires is advantageous to prevent formation of thrombotic emboli. New coiled tubular structures, having larger inner and outer diameter as compared to guidewires, are presented. In theory these tubes can be used as interposition vascular grafts. Ten coiled tubes with an internal diameter of 690 microm were made. Five different adherent polymeric coatings with increasing hydrophilicity were used. Five tubes contained heparin in the coating and the other five were unheparinised controls. The five tubes containing heparin were studied with respect to heparin release in vitro (amount released, kinetics), and immobilised heparin that is exposed at the surface. All tubes were studied with a direct cell contact assay using 3T3 mouse fibroblast cells, a dynamic thrombin generation test, and endothelial cell growth onto the coils. It was found that the heparinised tubes lead to very little thrombin formation. It is argued that this is due to heparin that is immobilised and exposed at the inner surface of such tubes. Furthermore the coils showed to be cytocompatible and endothelial cells adhere and proliferate well onto the coils. This concept is believed to hold promise for further development of small vascular grafts.

3T3 Cells↗

New modified polyetheretherketone membrane for liver cell culture in biohybrid systems: adhesion and specific functions of isolated hepatocytes.

There has been growing interest in innovative materials with physico-chemical properties that provide improved blood/cell compatibility. We propose new polymeric membranes made of modified polyetheretherketone (PEEK-WC) as materials with potential for use in biohybrid devices. PEEK-WC exhibits high chemical, thermal stability and mechanical resistance. Owing to its lack of crystallinity this polymer can be used for preparing membranes with cheap and flexible methods. We compared the properties of PEEK-WC membranes to polyurethane membranes prepared using the same phase inverse technique and commercial membranes. The physico-chemical properties of the membranes were characterised by contact angle measurements. The different parameters acid (gamma+), base (gamma-) and Lifshitz-van der Waals (gammaLW) of the surface free energy were calculated according to Good-van Oss's model. We evaluated the cytocompatibility of PEEK-WC membranes by culturing hepatocytes isolated from rat liver. Cell adhesion and metabolic behaviour in terms of ammonia elimination, urea synthesis and protein synthesis were evaluated during the first days of culture. Liver cells adhered and formed three-dimensional aggregates on the most tested membranes. PEEK-WC membranes promoted hepatocyte adhesion most effectively. Urea synthesis, ammonia elimination and protein synthesis improved significantly when cells adhered to PEEK-WC membrane. The considerable metabolic activities of cells cultured on this membrane confirmed the good structural and physico-chemical properties of the PEEK-WC membrane that could be a promising biomaterial for cell culture in biohybrid devices.

Animals↗

Development of hybrid materials based on hydroxyethylmethacrylate as supports for improving cell adhesion and proliferation.

A novel hydrogel based on 2-hydroxyethylmethacrylate and fumed silica nanoparticles is presented. The filler was mixed at increasing amount (3-40% w/w) to the organic monomer, before accomplish thermal polymerization. The hybrid composite materials obtained were characterized as far as concern the physical-chemical stability and sorption behaviour in water and water solutions. The novel hybrid hydrogels were compared to poly(hydroxyethylmethacrylate) (pHEMA) on cytocompatibility and ability to elicit cell adhesion and proliferation. These in vitro assays showed that the first ones were supporting cell growth better then pHEMA, moreover experiments on murine fibroblasts showed improved adhesion and proliferation with the increase of the nanomeric filler content. For a more physiological response, the in vitro tests should match biomaterials with cell populations typical of the implant site. Therefore, in view of future applications of these composites as scaffolds for bone engineering, in a successive step of our research we selected primary cultures of human osteoblasts (OB) as the most appropriate models to study the in vitro performance of these materials. The preliminary results obtained confirmed the remarkable improvement of OB adhesion properties of the new hybrids with respect to pure pHEMA.

Adult↗

Functional cardiac cell constructs on cellulose-based scaffolding.

Cellulose and its derivatives have been successfully employed as biomaterials in various applications, including dialysis membranes, diffusion-limiting membranes in biosensors, in vitro hollow fibers perfusion systems, surfaces for cell expansion, etc. In this study, we tested the potential of cellulose acetate (CA) and regenerated cellulose (RC) scaffolds for growing functional cardiac cell constructs in culture. Specifically, we demonstrate that CA and RC surfaces are promoting cardiac cell growth, enhancing cell connectivity (gap junctions) and electrical functionality. Being optically clear and essentially non-autofluorescent, CA scaffolds did not interfere with functional optical measurements in the cell constructs. Molding to follow fine details or complex three-dimensional shapes are additional important characteristics for scaffold design in tissue engineering. Biodegradability can be controlled by hydrolysis, de-acetylization of CA and cytocompatible enzyme (cellulase) action, with glucose as a final product. Culturing of cardiac cells and growth of tissue-like cardiac constructs in vitro could benefit from the versatility and accessibility of cellulose scaffolds, combining good adhesion (comparable to the standard tissue-culture treated polystyrene), molding capabilities down to the nanoscale (comparable to the current favorite in soft lithography-polydimethylsiloxane) with controlled biodegradability.

Action Potentials↗

Characterization of protein release from photocrosslinkable hyaluronic acid-polyethylene glycol hydrogel tissue engineering scaffolds.

The goal of this work was to utilize the naturally derived bioactive polymer hyaluronic acid (HA) to create a combination tissue engineering scaffold and protein delivery device. HA is a non-immunogenic, non-adhesive glycosaminoglycan that plays significant roles in several cellular processes, including angiogenesis and the regulation of inflammation. In previous work, we created photopolymerizable glycidyl methacrylate-hyaluronic acid (GMHA) hydrogels that had controlled degradation rates, were cytocompatible, and were able to be modified with peptide moieties. In the present studies, we characterized the release of a model protein, bovine serum albumin (BSA), from GMHA and GMHA-polyethylene glycol (PEG) hydrogels. Although BSA could be released rapidly (> 60% within 6 h) from 1% GMHA hydrogels, we found that increasing either the GMHA or the PEG concentrations could lengthen the duration of protein delivery. Preliminary size exclusion chromatography studies indicated that the released BSA was almost entirely in its native monomeric form. Lastly, protein release was extended to several weeks by suspending BSA-poly(lactic-co-glycolic acid) microspheres within the hydrogel bulk. These initial studies indicate that the naturally derived biopolymer HA can be employed to design novel photopolymerizable composites that are suitable for delivering stable proteins from scaffolding in tissue engineering applications.

Coated Materials, Biocompatible↗

Fabrication of well-defined PLGA scaffolds using novel microembossing and carbon dioxide bonding.

A novel biologically benign technique was developed to produce three-dimensional tissue engineering scaffolds with well-defined structure. Photolithography was used to design and pattern a planar scaffold skeletal structure on a photoresist (SU-8), and a variety of microembossing processes including sacrificial layer embossing and bilayer embossing were developed to transfer the skeletal pattern to the poly(DL-lactide-co-glycolide) substrate as scaffold skeletons. Subcritical carbon dioxide was then introduced to assemble these skeletons to a three-dimensional scaffold at a low temperature. Compared with conventional scaffolds, which have a broad pore size distribution and varying pore geometry, these microfabricated scaffolds have a uniform and well-defined geometry and structure. This uniformity of structural parameters allows for the studies of cell attachment, spreading, and proliferation in scaffolds in a controlled and logical manner. The cytocompatibility of these microfabricated scaffolds was tested by seeding three different cell lines with different morphologies and growth patterns into these scaffolds. All three cell lines attached well to the scaffolds and grew to high densities as observed with scanning electron microscopy. This study demonstrates a controllable method to fabricate tissue scaffolds with a well-defined 3D architecture that can be used to better elucidate the effect of structure parameters such as pore geometry and pore size on tissue growth in 3D scaffolds.

Animals↗

Design of functional hollow fiber membranes modified with phospholipid polymers for application in total hemopurification system.

In this study, we prepared cellulose acetate (CA) hollow fiber membranes (HFMs) modified with poly (2-methacryloyloxyethyl phosphorylcholine (MPC)-co-n-butyl methacrylate)(PMB30 and PMB80) by the dry-jet wet spinning process. The physical and chemical structures of the HFMs were controlled in order to design highly functional HFMs that had suitable performance to each targeting HFM device used in a total hemopurification system. The CA HFMs modified with the MPC polymer, such as CA/PMB30, CA/PMB80, and CA/PMB30-80 HFMs, were successfully prepared by controlling the spinning conditions. The modified HFMs showed an improved performance in solute and water permeability, due to the modification by the hydrophilic MPC polymers. The CA/PMB30 and CA/PMB80 showed a high potential in an application for a high performance hemocompatible plasmapheresis and hemofilter device. Furthermore, CA/PMB30-80 HFM, modified asymmetrically with PMB30 and PMB80, showed a potential for application in an advanced total hemopurification system as a highly functional scaffold for a biohybrid renal tubule, or a liver assist bioreactor device, because of their enhanced permeability, hemocompatibility, and cytocompatibility.

Animals↗

Preparation of gamma-PGA/chitosan composite tissue engineering matrices.

Gamma-poly(glutamic acid) (gamma-PGA), a hydrophilic and biodegradable polymer, was chosen to modify chitosan matrices to produce a gamma-PGA/chitosan composite biomaterial. Three types of both dense and porous composite matrices containing different amounts of gamma-PGA were fabricated. Chitosan and gamma-PGA matrices were also prepared as controls. Fluorescence staining indicated that chitosan and gamma-PGA were evenly distributed in the composite matrices. SEM micrographs showed that an interconnected porous structure with a pore size of 30-100 microm was present in all porous matrices except the gamma-PGA ones. By increasing the percentage of gamma-PGA from 0% to 20%, the swelling ratio of the matrices was enhanced from 1.6 to 3.2. Similarly, the contact angle of the matrices decreased from 113 degrees to 94 degrees . These data suggested that the surface hydrophilicity, water absorption rate, and swelling ratio were improved by adding gamma-PGA to the matrices. Additionally, the mechanical strength of the porous gamma-PGA/chitosan matrices was about 25-50%, higher than that of the unmodified chitosan matrices. The composite matrices were also examined and found to be an appropriate environment for cell attachment and proliferation. The cell density on the 20% gamma-PGA-modified matrices was almost triple that on the unmodified chitosan matrices on day 5. In summary, the gamma-PGA/chitosan composite matrices, due to their better hydrophilic, cytocompatible, and mechanical properties, are very promising biomaterials for tissue engineering applications.

Absorbable Implants↗

Transitory oxidative stress in L929 fibroblasts cultured on poly(epsilon-caprolactone) films.

Poly(epsilon-caprolactone) (PCL) is considered as a potential substrate for wide medical applications. In previous studies we carried out the in vitro biocompatibility assessment of PCL films using L929 mouse fibroblasts, obtaining good cell behaviour but a transitory stimulation of mitochondrial activity and cell retraction. Reactive oxygen species (ROS), mainly formed in mitochondria, can impair the function of several cellular components and produce cell oxidative stress by changing the normal red-ox status of the major cell antioxidants as glutathione. The aim of this study was to measure intracellular ROS production and glutathione content of L929 fibroblasts cultured on PCL films. Cell size, internal complexity, cell cycle and lactate dehydrogenase release were also evaluated. The films were treated with NaOH before culture to improve the cell-polymer interaction. PCL induces a transitory but significant oxidative stress in L929 fibroblasts. The treatment of PCL films with NaOH reduces this effect. PCL also induces transitory changes on cell size and complexity. Nevertheless, after 7 days in culture, cells reach control levels for all the studied parameters. Neither cell cycle nor membrane integrity appears affected by this oxidative stress respect to control cells at any culture time. These results underline the cytocompatibility of PCL films and, therefore, its potential utility as a suitable scaffold in tissue engineering.

Animals↗

Improvement of surface bioactivity on titanium by water and hydrogen plasma immersion ion implantation.

We have investigated the surface bioactivity of titanium after water and hydrogen plasma immersion ion implantation. Plasma immersion ion implantation (PIII) excels in the surface treatment of components possessing a complicated shape such as medical implants. In addition, water and hydrogen PIII has been extensively studied as a method to fabricate silicon-on-insulator (SOI) substrates in the semiconductor industry and so it is relatively straightforward to transfer the technology to the biomedical field. In our investigation, water and hydrogen were plasma-implanted into titanium sequentially. Our objective is that water PIII introduces near-surface damages that trap hydrogen implanted in the subsequent step to improve the surface bioactivity while the desirable bulk properties of the materials are not compromised. Ti-OH functional groups can be detected on the (H(2)O+H(2))-implanted titanium surface by X-ray photoelectron spectroscopy (XPS) and Fourier transform infrared (FTIR) spectroscopy. After incubation in simulated body fluids (SBF) for cytocompatibililty evaluation in vitro, bone-like hydroxyapatite was found to precipitate on the (H(2)O+H(2)) implanted samples while no apatite was found on titanium samples plasma implanted with water or hydrogen alone. Human osteoblast cells were cultured on the (H(2)O+H(2))-implanted titanium surface and they exhibited good adhesion and growth. Our results suggest a practical means to improve the surface bioactivity and cytocompatibility of medical implants made of titanium.

Biocompatible Materials↗

Interactions between endothelial cells and a poly(carbonate-silsesquioxane-bridge-urea)urethane.

We have recently developed a polymer which contains silsesquioxane in the form of nano-bridges poly(carbonate-silsesquioxane-bridge-urea)urethane (PCBSU) for cardiovascular device applications. The polymer has been characterised and the durability has been confirmed with long-term in vivo tests. The aim of this study was to test the cytocompatibility of the new polymer and to investigate any potential cytotoxic effects. To assess the effect of direct contact with PCBSU sections of polymer material were cut and placed into a 24-well plate. Six discs were seeded with 2 x 10(5) human umbilical vein cells (HUVEC). As a positive control, six wells were seeded with the same number of HUVEC. In a further experiment to assess indirect contact with PCBSU a sample of the polymer was powdered using a Micro-Dismembrator. Cell culture medium was exposed to powdered polymer (1-100 mg/ml) for a period of 7 days. HUVEC seeded as above were then exposed to the treated cell culture medium for 24 and 96 h. Finally, cell proliferation was studied over 16 days by seeding 2 x 10(5) HUVEC on films of PCBSU cast in glass Petri dishes. Cell viability and growth were assessed using Alamar blue, lactate dehydrogenase and Pico green assays and morphology was studied by Toluidine blue staining and scanning electron microscopy. Viable cells were demonstrated to be present after 16 days seeded on PCBSU. Exposing cells to PCBSU-treated cell culture medium resulted in no apparent damage to the cells at concentrations of 1 or 10 mg/ml, and only a slight reduction at 100 mg/ml after 96 h exposure. This study demonstrates that PCBSU can support the growth of endothelial cells for a prolonged period and does not demonstrate any significant toxic effects to cells. Thus it has the potential to be used both as a medical device and as scaffolding in tissue engineering applications.

Apoptosis↗

Covalent conjugation of polyethyleneimine on biodegradable microparticles for delivery of plasmid DNA vaccines.

Microparticle-based delivery of nucleic acids has gained particular attention in recent years in view of improving the potency of DNA vaccination. Such improvement has been reported by encapsulation of pDNA within biodegradable microparticles or through surface adsorption on cationic microparticles. However, the intrinsic intracellular barriers for gene delivery to antigen presenting cells (APCs) have not been adequately addressed in the rational design of delivery systems for DNA vaccines. Here we report synthesis and characterization of biodegradable microparticles that (a) can passively target phagocytic APCs, (b) have intrinsic buffering ability that might allow for enhanced phagosomal escape, (c) are not cytotoxic and (d) have improved APC transfection efficiency. Branched polyethyleneimine (b-PEI) was covalently conjugated using carbodiimide chemistry to the surface of poly(lactide-coglycolide) (PLGA) microparticles to create cationic microparticles capable of simultaneously delivering both DNA vaccines as well as other immunomodulatory agents (cytokines or nucleic acids) within a single injectable delivery vehicle. Our results indicate that covalent conjugation of b-PEI allows efficient surface loading of nucleic acids, introduces intrinsic buffering properties to PLGA particles and enhances transfection of phagocytic cells without affecting the cytocompatibility of PLGA carriers.

Absorbable Implants↗

A silanized hydroxypropyl methylcellulose hydrogel for the three-dimensional culture of chondrocytes.

Articular cartilage has limited intrinsic repair capacity. In order to promote cartilage repair, the amplification and transfer of autologous chondrocytes using three-dimensional scaffolds have been proposed. We have developed an injectable and self-setting hydrogel consisting of hydroxypropyl methylcellulose grafted with silanol groups (Si-HPMC). The aim of the present work is to assess both the in vitro cytocompatibility of this hydrogel and its ability to maintain a chondrocyte-specific phenotype. Primary chondrocytes isolated from rabbit articular cartilage (RAC) and two human chondrocytic cell lines (SW1353 and C28/I2) were cultured into the hydrogel. Methyl tetrazolium salt (MTS) assay and cell counting indicated that Si-HPMC hydrogel did not affect respectively chondrocyte viability and proliferation. Fluorescent microscopic observations of RAC and C28/I2 chondrocytes double-labeled with cell tracker green and ethidium homodimer-1 revealed that chondrocytes proliferated within Si-HPMC. Phenotypic analysis (RT-PCR and Alcian blue staining) indicates that chondrocytes, when three-dimensionnally cultured within Si-HPMC, expressed transcripts encoding type II collagen and aggrecan and produced sulfated glycosaminoglycans. These results show that Si-HPMC allows the growth of differentiated chondrocytes. Si-HPMC therefore appears as a potential scaffold for three-dimensional amplification and transfer of chondrocytes in cartilage tissue engineering.

Animals↗

Surface engineering of stainless steel materials by covalent collagen immobilization to improve implant biocompatibility.

It was shown recently that the deposition of thin films of tantalum and tantalum oxide enhanced the long-term biocompatibility of stainless steel biomaterials due to an increase in their corrosion resistance. In this study, we used this tantalum oxide coating as a basis for covalent immobilization of a collagen layer, which should result in a further improvement of implant tissue integration. Because of the high degradation rate of natural collagen in vivo, covalent immobilization as well as carbodiimide induced cross-linking of the protein was performed. It was found that the combination of the silane-coupling agent aminopropyl triethoxysilane and the linker molecule N,N'-disulphosuccinimidyl suberate was a very effective system for collagen immobilizing. Mechanical and enzymatic stability testing revealed a higher stability of covalent bound collagen layers compared to physically adsorbed collagen layers. The biological response induced by the surface modifications was evaluated by in vitro cell culture with human mesenchymal stem cells as well as by in vivo subcutaneous implantation into nude mice. The presence of collagen clearly improved the cytocompatibility of the stainless steel implants which, nevertheless, significantly depended on the cross-linking degree of the collagen layer.

Adsorption↗

Electrospinning of collagen nanofibers: effects on the behavior of normal human keratinocytes and early-stage wound healing.

Electrospinning of type I collagen in 1,1,1,3,3,3-hexafluoro-2-propanol (HFIP) to fabricate a biomimetic nanofibrous extracellular matrix for tissue engineering was investigated. The average diameter of collagen nanofibers electrospun from 8% collagen solution in HFIP was 460 nm (range of 100-1200 nm). The as-spun collagen nanofibrous matrix was chemically cross-linked by glutaraldehyde vapor with a saturated aqueous solution and then treated with aqueous 0.1m glycine to block unreacted aldehyde groups. With vapor phase cross-linking for 12h, porosity of the collagen matrix decreased from 89% to 71%. The collagen nanofibrous matrix showed good tensile strength, even in aqueous solution. Effects on cytocompatibility, cell behavior, cell and collagen nanofiber interactions, and open wound healing in rats were examined. Relatively low cell adhesion was observed on uncoated collagen nanofibers, whereas collagen nanofibrous matrices treated with type I collagen or laminin were functionally active in responses in normal human keratinocytes. Collagen nanofibrous matrices were very effective as wound-healing accelerators in early-stage wound healing. Our results indicate that cross-linked collagen nanofibers coated with ECM proteins, particularly type I collagen, may be a good candidate for biomedical applications, such as wound dressing and scaffolds for tissue engineering.

Adult↗

High functional hollow fiber membrane modified with phospholipid polymers for a liver assist bioreactor.

For practical application of a liver assist system with a tissue-conjugated hollow fiber membrane (HFM) bioreactor used in an extracorporeal therapy, it would require a highly sophisticated HFM which has both hemocompatibility on one side and cytocompatibility on the other side. In this study, we present a cellulose acetate (CA) HFM modified with 2-methacryloyloxyethyl phosphorylcholine (MPC) copolymers (PMB30 (MPC-co-n-butyl methacrylate) and PMA30 (MPC-co-methacrylic acid) for preparing a novel liver assist HFM bioreactor. A CA/PMB-PMA30 HFM modified asymmetrically on the inner and outer surface with the PMB30 and PMA30 was prepared successfully. Analysis with an X-ray photoelectron spectroscope showed that the intensity of the phosphorus atom attributed to the MPC units on the outer surface of the modified HFM was stronger than that of the inner surface. The PMA30 was immobilized on the outer surface of the CA/PMB30 blend HFM by a chemical condensation reaction. The CA/PMB-PMA30 HFM showed good water and solute permeability in comparison with the CA HFM. The morphologies of the adherent hepatocytes were round in shape in comparison with the cells that adhered on CA HFM. Furthermore, hepatocytes cultured on the inner surface of the CA/PMB-PMA30 HFM showed higher functional expression in terms of urea synthesis and albumin synthesis than that of the CA HFM.

Animals↗

Electrospinning of chitin nanofibers: degradation behavior and cellular response to normal human keratinocytes and fibroblasts.

An electrospinning method was used to fabricate chitin nanofibrous matrices for biodegradability and cell behavior tests. The morphology of as-spun chitin nanofibers (Chi-N) and commercial chitin microfibers (Beschitin W; Chi-M) was investigated by scanning electron microscopy. From the image analysis, the average diameters of Chi-N and Chi-M were 163 nm and 8.77 microm, respectively. During in vitro degradation for 15 days, the degradation rate of Chi-N was faster than that of Chi-M, likely due to higher surface area of Chi-N. Chi-N that was grafted into rat subcutaneous tissue had almost degraded within 28 days, and no inflammation could be seen on the nanofiber surfaces or in the surrounding tissues (except in the early stage wound). To assay and compare the cytocompatibility and cell behavior with Chi-N and Chi-M, cell attachment and spreading of normal human keratinocytes and fibroblasts seeded on chitin matrices and the interaction between cells and chitin fibers were studied. Relatively high cell attachment and spreading of all the cells tested were observed on Chi-N in comparison to Chi-M, and Chi-N treated with type I collagen significantly promoted the cellular response. Our results indicate that the Chi-N, alone or with extracellular matrix proteins (particularly type I collagen), could be potential candidates for the cell attachment and spreading of normal human keratinocytes and fibroblasts. This property of Chi-N might be particularly useful for wound healing and regeneration of oral mucosa and skin.

Absorbable Implants↗