Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Titanium”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12Linked to original sources

Evaluation of corrosion on plasma sprayed and anodized titanium implants, both with and without bone cement.

The corrosion behavior of titanium with vacuum plasma sprayed titanium coatings and with anodized surfaces, both with and without polymeric bone cement were evaluated. Electrochemical extraction tests were carried out with subsequent analysis of the electrolyte by ICP-MS in order to verify our hypothesis of the ionic permeability of the polymer cement. The complexity of the situation resides in the existence of two interfaces: electrolyte-polymer and polymer-metal. The surface preparation (treatment of the surface) plays an important role in the corrosion resistance of titanium. The electrochemical magnitudes that were examined reveal that the plasma spray surfaces have the lowest corrosion resistance. The cement, in spite of having reduced electrical conductivity in comparison to metal, is an ionic transporter, and therefore capable of participating in the corrosion process. In the present study, we observed in fact crevice corrosion at the metal-cement interface. In the case of plasma spray surfaces, a process of diffusion of titanium particles in the electrolyte could accompany the crevice corrosion. In this study, we have shown that there is a corrosion process at the surface of the titanium through the cement which has as a consequence on the one hand the formation of titanium cations and on the other hand the growth of a passive layer on the titanium. In conclusion, we identified two principal factors that influence the corrosion process: [1] the type of surface treatment for the titanium, and [2] the ionic conductivity of the cement. There is indeed ionic transport through the cement; as evidenced by the presence of titanium in the electrolyte solution (ICP-MS analysis) and chloride at the surface of the titanium sample (EDX analysis). We show that the polymer cement is an ionic conductor and participates in the corrosion of the embedded titanium. We cannot deduce from our results, however, whether the polymer itself possesses corrosive properties. Long-term experiments will be necessary to study the degradation behavior of the polymer cement.

Coated Materials, Biocompatible↗

Incorporation of titanium mesh in orbital and midface reconstruction.

Several authors have demonstrated the safety and effectiveness of titanium in orbital reconstruction. One question posed by clinicians is what happens to large pieces of titanium in communication with the paranasal sinuses or nasal-oral-pharyngeal area. This question becomes increasingly relevant as titanium is used to reconstruct extensive defects for which the destruction of bony architecture requires the placement of mesh in proximity to these areas. The objective of this study was to examine the gross and histologic soft-tissue response to large segments of titanium mesh in the setting of orbital and midface reconstruction, particularly when exposed to the nasal-oral-pharyngeal area and paranasal sinuses. In this study, large segments of titanium mesh were used in eight patients to reconstruct orbital and midface defects, with direct communication between the mesh and nasal-oral-pharyngeal area and paranasal sinuses. Four patients had suffered self-inflicted gunshot wounds; as a result, much of their midface was missing, including the inferior and medial orbital floor, maxilla, nose, naso-orbital-ethmoid complex, and hard palate. Extensive sheets of titanium mesh were used to reconstruct their medial and inferior orbital walls, nasal bridge, and maxilla. In the fifth patient, titanium mesh was used to reconstruct the maxilla after resection of a squamous cell carcinoma of the nasolacrimal duct. In the sixth and seventh patients, mesh was used to reconstruct the nasal bridge after severely comminuted nasal fractures resulted in the loss of bone and mucosa. Finally, the eighth patient had titanium mesh used to replace cocaine-induced bone loss involving the left medial orbital floor and wall and part of the maxilla. On gross examination by either endoscopy or direct inspection, all eight patients had rapid soft-tissue incorporation of the titanium mesh. Initial examination typically revealed budding of soft tissue through mesh interstices, followed by progressive incorporation. One patient's mesh was covered in only 15 days. Two patients underwent biopsies of this newly formed soft tissue. One had biopsies performed at 3, 15, and 31 months after the original operation. Biopsy examination at 3 months revealed incorporation of the titanium with fibrous soft tissue covered by ciliated respiratory epithelium, goblet cells, and squamous epithelium with metaplasia. In addition, the dense, acute inflammation present at 3 months evolved into mild, chronic inflammation at 31 months. The second patient had a single biopsy 4 months after secondary orbital reconstruction for delayed enophthalmos. Biopsy examination revealed a fibrous soft-tissue sheath lined by squamous epithelium with metaplasia. Again, mild chronic inflammation was present within the soft tissue. This study provides evidence of titanium's compatibility with soft tissue. The mesh underwent progressive incorporation with soft tissue that was then resurfaced by indigenous cells, including respiratory epithelia and goblet cells. This phenomenon occurred despite communication with the nasal-oral-pharyngeal area and paranasal sinuses.

Bone Diseases↗

Antibacterial activity of zinc modified titanium oxide surface.

Titanium-based implants are successfully used for various biomedical applications. However, in some cases, e.g. in dental implants, failures due to bacterial colonization are reported. Surface modification is a commonly proposed strategy to prevent infections. In this work, titanium oxide, naturally occurring on the surface of titanium, was modified by promoting the formation of a mixed titanium and zinc oxide, on the basis of the idea that zinc oxide on titanium surface may act as the zinc oxide used in pharmaceutical formulation for its lenitive and antibacterial effects. The present work shows that it is possible to form a mixed titanium and zinc oxide on titanium surfaces, as shown by Scanning Electron Microscopy and XPS analysis. To this end titanium was preactivated by UV on crystalline titanium oxide, both in the anatase form or in the co-presence of anatase and rutile. By performing antibacterial assays, we provide evidence of a significant reduction in the viability of five streptococcal oral strains on titanium oxide surfaces modified with zinc. In conclusion, this type of chemical modification of titanium oxide surfaces with zinc might be considered a new way to reduce the risk of bacterial colonization, increasing the lifetime of dental system applications.

Anti-Bacterial Agents↗

Hydroxyapatite and carbon coatings for fixation of unloaded titanium implants.

The aim of this study was to investigate the interaction between bone and pure titanium, titanium coated with hydroxyapatite (HA), and titanium coated with carbon in a rat femur model. In 25 rats, the medullary cavity of both femurs was entered by an awl from the trochanteric area. With steel burrs it was successively reamed to a diameter of 2.0 mm. Nails with a diameter of 2.0 mm and with a length of 34 mm were inserted in a random manner; either a pure titanium nail, a titanium nail entirely plasma-sprayed with a 75-100-microm layer of HA or a titanium nail coated with 2-10-microm carbon. The surface roughness of the pure titanium was characterized by Ra 2.6 microm and Rt 22 microm. Ra of HA was 7.5 microm and Rt 52 microm, and of carbon Ra was 0.4 microm and Rt 4.0 microm. Twelve rats were randomized to a follow up of 8 weeks, and the remaining 13 rats were followed for 16 weeks. At sacrifice both femora were dissected free from soft tissues and then immersed in fixative. A specimen slice of about 5 mm thickness was prepared from the subtrochanteric region with a water-cooled band-saw. Sample preparation for un-decalcified tissue followed the internal guidelines at the laboratories of Biomaterials/Handicap Research. At 8 weeks the median bone bonding contact of the implants was 43% (range 0-74) in the titanium group, 39% (0-75) in the HA group, and 3% (0-59) in the carbon group. At 16 weeks the corresponding figures were 58% (0-78) in the titanium group, 51% (15-75) in the HA group, and 8% (0-79) in the carbon group. In conclusion, we found great variability in bone bonding contact. In general, carbon-coated nails had reduced bone bonding contact both at 8 and at 16 weeks as compared to pure titanium or titanium coated with hydroxyapatite.

Analysis of Variance↗

Interaction of chlorhexidine with smooth and rough types of titanium surfaces.

BACKGROUND: Chlorhexidine (CHX) digluconate exerts plaque inhibitory efficacy in the natural dentition environment due to a superior degree of persistence at the tooth surface. The purpose of the present study was to assess the interaction of CHX with titanium surfaces to estimate its antiplaque potential in the peri-implant environment. METHODS: Saliva-coated machined smooth (S) and sand-blasted acid-etched rough (R) titanium disks were soaked in either 0.1% or 0.2% CHX solution. After 24 hours, CHX amounts that were adsorbed, washed out, and desorbed from the titanium surfaces were determined spectrophotometrically at 230 nm. The antibacterial activity of CHX-treated titanium disks was assessed by measuring bacterial inhibition zones on Streptococcus mutans lawns. RESULTS: Titanium disks adsorbed 3% to 8% of the available CHX, which was significantly higher with 0.2% CHX (P<0.001) than with 0.1% CHX and two-fold higher on the R titanium disks compared to S titanium surface (P<0.001). After rinsing with water, 2.2% of the adsorbed CHX was washed out. Over 24 hours, S- and R-type disks released 1.1% and 0.6% of the adsorbed agent, respectively. Larger bacterial inhibition zones were obtained with 0.2% CHX and in R disks compared to S disks. CONCLUSIONS: CHX displayed persistence at the titanium surface. The adsorption level and bacterial growth inhibition were affected by CHX concentration and titanium surface characteristics, with higher levels of adsorption and antibacterial activity with 0.2% CHX and rough titanium surface. The slow CHX release rate suggests persistence of this agent at the titanium-pellicle surface, which can provide a long-term antiplaque effect.

Adsorption↗

Inflammatory infiltrate, microvessel density, nitric oxide synthase expression, vascular endothelial growth factor expression, and proliferative activity in peri-implant soft tissues around titanium and zirconium oxide healing caps.

BACKGROUND: The aim of the present study in humans was to conduct a comparative immunohistochemical evaluation of vascular endothelial growth factor (VEGF) and nitric oxide synthase (NOS) expression, inflammatory infiltrate, proliferative activity expression, and microvessel density (MVD) in peri-implant soft tissues of titanium and zirconium oxide healing caps. METHODS: Five patients, three men and two women (aged 30 to 66 years; mean: 49 years), participated in this study. All patients received dental implants that were 3.8 mm in diameter and 11 mm in length. All implants were left to heal in a non-submerged (single-stage) mode. Healing caps (3.8 mm in diameter and 3.0 mm in height) were inserted in all implants. Half of the implants were supplied with standard, prefabricated caps of commercially pure titanium, whereas the other half were provided with test zirconium oxide caps. After a 6-month healing period, a gingival biopsy was performed with a circular scalpel (5.5 mm in diameter) around the healing caps of both groups, without unscrewing or removing the healing caps. The dimensions of the gingival biopsies were 1.7 mm (5.5-3.8 mm) in thickness and 3 mm in height. RESULTS: Statistically significant differences were found in the microvessel density between titanium and zirconium oxide healing caps and group II (P < or = 0.0001). Statistically significant differences were likewise found in the low and high intensities of NOS1, NOS3, and VEGF (P < or = 0.0001). In conclusion, the high intensity of NOS1, NOS3, and VEGF were mostly expressed in the titanium group, whereas the low intensity of NOS1, NOS3, and VEGF were mostly expressed in the zirconium oxide group. CONCLUSIONS: In our specimens, the inflammatory infiltrate was mostly present in the titanium specimens. Their extension was much larger than that of the zirconium oxide specimens. Higher values of MVD were observed in the titanium specimens (29.1 versus 15.8). In addition, a higher expression of VEGF intensity was observed in the peri-implant tissues of titanium healing caps, whereas predominantly lower expressions of VEGF intensity were noted around the zirconium oxide healing caps. The Ki-67 expression was higher in the titanium specimens. All these data revealed that the tissues around titanium healing caps underwent a higher rate of inflammation-associated processes, most probably correlated to the higher inflammation processes observed in these tissues. A higher intensity expression of NOS1 and NOS3 was recorded in the tissues around titanium, whereas, on the contrary, a lower intensity of expression was found in the tissues around zirconium oxide specimens. These latter data indicate that the higher expression of these two mediators could be correlated to the higher amount of bacteria present around the titanium samples.

Adult↗

[The influences of crystallized compositions in the porcelain on bonding strength of titanium to porcelain].

OBJECTIVE: Sufficient porcelain-titanium bond is a vital factor determining the clinical performance of titanium-porcelain restorations. The purpose of this study was to investigate the effects of self-preparation La-porcelain composition on the porcelain-titanium bonding strength and to compare with the Vita Titankeramik. METHODS: The present study examines 5 different recipes of porcelain by weight%: SiO2, 12%-17%; LaO2, 7%-10%; Al2O3, 9%-14%; B2O3, 23%-31%; CaO, 6%-8%; K2O, 2%-3%; SrO, 2%-4%; Na2O, 1%-3%; SnO2, 8%-10%; ZrO2, 3%-5%; TiO2, 6%-8%. Specimens were tested in push type shear with a universal testing machine. Scanning electron microscopy (SEM) and electron probe microanalyzer (EPMA) were employed to reveal the microstructures and diffusion of elements in the interfacial regions between the porcelain coating and titanium to the bond strength when fired at 800 degrees C. RESULTS: The ratios of crystallized compositions had significant influences on the porcelain-titanium bond strength (P < 0.05). La-porcelain had the highest shear bond strength (37.76 MPa). The shear bond strength of the Vita Titankeramik to titanium was 20.18 MPa. The results of SEM revealed integrity of porcelain-titanium joints in La-porcelain and a greater amount of porosity in the interface of Vita Titankeramik to titanium. EPMA analysis demonstrated the aggregation of Si and Sn in the interfacial regions and their diffusion into the titanium. CONCLUSION: Chemical compositions of porcelain and ratios of crystallized compositions play the important role in the titanium porcelain bond. La-porcelain had the highest shear bond strength and good porcelain-titanium joints. La-porcelain is a new-style low fusing porcelain/titanium system.

Crystallization↗

Effect of titanium surface roughness on human osteoblast proliferation and gene expression in vitro.

PURPOSE: Cell proliferation and extracellular matrix formation are primary events in bone formation. At the dental implant-tissue interface, implant surface roughness modulates osteoblast functions. The aim of the present in vitro study was to investigate the effect of varying surface roughness of titanium implant material on cell proliferation and mRNA expression of specific markers of osteoblast phenotype. MATERIALS AND METHODS: Primary cultures of osteoblasts derived from human mandibular bone were cultured on titanium surfaces. Three titanium surfaces were studied: machined titanium, microsandblasted titanium, and macro-sandblasted titanium (average surface roughnesses of 0.5 and 3 microm, respectively). Cell morphology was estimated by scanning electron microscope analysis and cell proliferation by measuring the amount of 3H-thymidine incorporation into DNA. mRNA expression of osteonectin, osteopontin, bone sialoprotein (BSP), and Runx2, which are markers of osteoblastic phenotype, were determined by reverse transcriptase polymerase chain reaction (RT-PCR) analysis. RESULTS: Human osteoblasts cultured on machined titanium spread more and were flatter than cells cultured on rough titanium. All blasted surfaces showed significantly higher DNA synthesis than the machined surfaces. Osteonectin mRNA expression was similar on all surfaces. Other mRNA transcripts were increased in osteoblasts cultured on rough titanium surfaces, particularly the macrosandblasted surface. CONCLUSIONS: An average surface roughness of 3 microm (macro-sandblasted titanium) is more suitable than an average surface roughness of 0.5 microm (micro-sandblasted titanium) in favoring osteoblast differentiation in vitro.

Analysis of Variance↗

A novel volumetric method for quantitation of titanium dioxide in cosmetics.

Nowadays there are many sun-protection cosmetics incorporating organic or inorganic UV filters as active ingredients. Chemically stable inorganic sunscreen agents, usually metal oxides, are widely employed in high-SPF (sun protection factor) products. Titanium dioxide is one of the most frequently used inorganic UV filters. It has been used as a pigment for a long period of cosmetic history. With the development of micronization techniques, it has become possible to incorporate titanium dioxide in sunscreen formulations without the previous whitening effect, and hence its use in cosmetics has become an important research topic. However, there are very few works related to quantitation of titanium dioxide in sunscreen products. In this research, we analyzed the amounts of titanium dioxide in sunscreen cosmetics by adapting redox titration, reduction of Ti(IV) to Ti(III), and reoxidation to Ti(IV). After calcification of other organic ingredients of cosmetics, titanium dioxide is dissolved by hot sulfuric acid. The dissolved Ti(IV) is reduced to Ti(III) by adding metallic aluminum. The reduced Ti(III) is titrated against a standard oxidizing agent, Fe(III) (ammonium iron(III) sulfate), with potassium thiocyanate as an indicator. In order to test the accuracy and applicability of the proposed method, we analyzed the amounts of titanium dioxide in four types of sunscreen cosmetics, namely cream, make-up base, foundation, and powder, after adding known amounts of titanium dioxide (1 approximately 25 w/w%). The percentages of titanium dioxide recovered in the four types of formulations were in the range between 96% and 105%. We also analyzed seven commercial cosmetic products labeled with titanium dioxide as an ingredient and compared the results with those obtained from ICP-AES (inductively coupled plasma-atomic emission spectrometry), one of the most powerful atomic analysis techniques. The results showed that the titrated amounts were well in accord with the analyzed amounts of titanium dioxide by ICP-AES. Although instrument-based analytical methods, namely ICP-MS (inductively coupled plasma-mass spectrometry) and ICP-AES, are best for the analysis of titanium, it is difficult for small cosmetic companies to install such instruments because of their high cost. It was found that the volumetric method presented here gives quantitatively accurate and reliable results with routine lab-ware and chemicals.

Cosmetics↗

Porcelain adherence to dental cast CP titanium: effects of surface modifications.

OBJECTIVES: A reaction layer forms on cast titanium surfaces due to the reaction of the molten titanium with the investment material. Such a layer prevents strong adhesion between titanium and porcelain. This study characterized the effects of surface modifications on cast titanium surfaces and titanium-ceramic adhesion. METHODS: ASTM grade II CP titanium was cast into an MgO-based mold. Castings were devested by sandblasting with alumina particles, and subjected to surface modification by immersion in one of the following solutions: (1) 35% HNO3-5% HF at room temperature for 1min; (2) 50% NaOH-10% CuSO4 x 5H2O at 105 degreesC for 10min; (3) the NaOH-CuSO4 solution followed by the HNO3-HF solution; (4) 50% NaOH-10% NaSO4 at 105 degreesC for 10 min; (5) the NaOH-NaSO4 solution followed by the HNO3-HF solution; and (6) 50% NaOH solution at 105 degreesC for 10min. Surfaces only sandblasted with alumina were used as controls. Specimen surfaces were characterized by XRD and SEM/EDS, and hardness-depth profiles were determined. All specimens were sandblasted with 110 microm alumina particles before porcelain firing. An ultra-low-fusing porcelain (Vita Titankeramik) was fused on the titanium surfaces. The titanium-ceramic adhesion was characterized by a biaxial flexure test, and area fraction of adherent porcelain (AFAP) was determined by X-ray spectroscopy. RESULTS: EDS analyses revealed a substantial amount (13-17 wt%) of Al on the control, and specimens modified with Methods 2, 4, and 6. XRD revealed residual stress in the titanium surfaces and corundum on the control, and Methods 2, 4, and 6 specimens. A new Ti(Cu, Al)2 phase was identified on the titanium surfaces modified by immersion in 50% NaOH-10% CuSO4 x 5H2O aqueous solution. Reduced residual stress was observed on Method 1, 3, and 5 specimens. No corundum peaks were detected on these specimens. Compared to the control, significantly lower (P < 0.05) hardness values were found for Methods 1-3 and Method 5 specimens at 20 microm below the surfaces and for Method 1-5 specimens at 50 microm below the surfaces. Significantly higher (P < 0.05) AFAP values were found for surfaces modified with Methods 2-6 compared to the control and Method 1, and no significant differences were found among Methods 1-6, and between control and Method 1. SIGNIFICANCE: Based on the results from the present study, porcelain adherence to cast CP titanium can be improved by the caustic baths used in the study.

Dental Casting Investment↗

Enhanced mineralized tissue adhesion to titanium over polystyrene assessed by the nano-scratch test.

The critical load determined by the scratch test is regarded to be a representative measure of coating adhesion in the field of engineering. This study aimed to evaluate the method for its usefulness for assessing the mineralized tissue-titanium interface strength. Osteoblastic cells derived from rat bone marrow were cultured on polystyrene, titanium-coated polystyrene, and titanium disks with either a machined or dual-acid etched surface. Nano-scratch testing was performed on mineralized tissue specimens at culture day 28. The scratch path was monitored by light microscopy until complete delamination of mineralized tissue from the substrate occurred, and the required force was recorded as the critical load. Energy-dispersive spectroscopic analysis was used to verify the delamination. The mean critical load values (+/- standard deviations) were as follows: polystyrene 31 mN (+/-1), titanium-coated polystyrene 67 mN (+/-4), machined titanium 76 mN (+/-4), DAE titanium 107 mN (+/-3), with statistical differences (P < 0.05; ANOVA). No elemental calcium and phosphorous were observed in the delaminated areas. The nano-scratch test applied to cultured mineralized tissue differentiated the critical load from various culture conditions: polystyrene vs. titanium; titanium with different surface topographies. Culturing mineralized tissue on titanium, especially on roughened surfaces, increased the tissue critical load. The nano-scratch test may be useful to evaluate mineralized tissue adhesion properties in titanium cultures.

Animals↗

Microstructures of beta-titanium orthodontic wires joined by infrared brazing.

The microstructures and interdiffusion in brazed beta-titanium orthodontic wires were investigated by scanning electron microscopy and electron probe microanalysis, respectively. Beta-titanium wire (Ti-11Mo-6Zr-4Sn) with cross-section dimensions of 0.032 in. x 0.032 in., titanium-based braze alloy (Ti-30Ni-20Cu), and silver-based braze alloy (Ag-22Cu-17Zn-5Sn) were selected for the study. Brazing was performed using infrared radiation (RS-1) under an argon atmosphere. Specimens were etched with two solutions (2.5% HF + 2.5% HNO(3) + 95% H(2)O; 25% HN(4)OH + 30% H(2)O(2) + 45%H(2)O). It was found that the silver-based braze alloy has a eutectic structure. In the diffusion layer between the beta-titanium wire and this silver-based braze alloy, Cu and Ti were enriched on the wire side, and Sn and Ti were enriched on the braze alloy side. The titanium-based braze alloy has a dendritic structure. Beta-titanium wire specimens brazed with the titanium-based braze alloy had a thicker intermediate area compared to the silver alloy; Ti in the diffusion layer had an irregular concentration gradient, and the braze alloy side had higher Ti concentration. The original microstructure of the beta-titanium wire was not altered with the use of either braze alloy. Infrared brazing of beta-titanium orthodontic wire is acceptable for clinical use, since the wire microstructure did not deteriorate with either the titanium-based or silver-based braze alloy. The differing microstructures of the joint regions for the two braze alloys suggest that the joint strengths may also differ.

Dental Soldering↗

Effects of airborne-particle abrasion, sodium hydroxide anodization, and electrical discharge machining on porcelain adherence to cast commercially pure titanium.

The aim of this study was to determine the effect of airborne-particle abrasion (APA), sodium hydroxide anodization (SHA), and electrical discharge machining (EDM) on cast titanium surfaces and titanium-porcelain adhesion. Ninety titanium specimens were cast with pure titanium and the alpha-case layer was removed. Specimens were randomly divided into three groups. Ten specimens from each group were subjected to APA. SHA was applied to the second subgroups, and the remaining specimens were subjected to the EDM. For the control group, 10 specimens were cast using NiCr alloy and subjected to only APA. Surfaces were examined by using scanning electron microscope and a surface profilometer. Three titanium porcelains were fused on the titanium surfaces, whereas NiCr specimens were covered with conventional porcelain. Titanium-porcelain adhesion was characterized by a 3-point bending test. Statistical analysis showed that the porcelain-metal bond strength of the control group was higher than that of the titanium-porcelain system (p < 0.05). There were no significant differences between the bond strengths of titanium groups (p 0.05), except the bond strengths of Noritake Super Porcelain TI-22 groups on which APA and SHA were applied (p < 0.05). SHA and EDM as surface treatment did not improve titanium-porcelain adhesion when compared to APA.

Chromium Alloys↗

Effects of hydrothermal treatment with CaCl(2) solution on surface property and cell response of titanium implants.

In order to obtain early and good osteointegration after implantation of a titanium implant in the human body, the surface modified treatments using NaOH or H(2)O(2) etc. were reported. In this study, titanium was hydrothermally treated with CaCl(2) solutions at 200 degrees C for 24hr (CaCl(2)-HT). Scanning electron microscope (SEM) observation clearly showed apatite deposition on the surface of CaCl(2) HT treated titanium faster than other chemical treated titanium immersion in simulated body fluid. X-ray photoelectron spectroscopy (XPS) analysis demonstrated that Ti--O--Ca bonding was formed on titanium surface by hydrothermal treatment with CaCl(2) solution. And it was revealed that thickness of TiO(2), which was known to play important roles for the formation of bone-like apatite, became approximately three times thicker than as-polished titanium. The amount of initial attached MC3T3-E1 cells on as-polished and NaOH, H(2)O(2) and this CaCl(2) HT treated titanium were almost the same values. After 5 days incubation, the growth rate of MC3T3-E1 cells on CaCl(2)-HT treated titanium was significantly higher than that on other chemical treated titanium. The hydrothermal treatment with 10-20 mmol/L CaCl(2) solution at 200 degrees C was an effective method for the fabrication of titanium implant with good bioactivity and osteoconductivity.

3T3 Cells↗

A comparison of the hardness of different types of titanium and conventional metal ceramics.

This study compared the surface hardness of machine milled titanium and cast titanium, and the surface hardness profile of a gold-palladium alloy, a nickel chromium alloy, milled and cast titanium. For each group, 15 discoid specimens, 10 mm in diameter and 5 mm thick, were fabricated by either casting or milling. Five specimens of each group underwent one of three treatments: (1) no heat treatment, (2) a standard heat treatment, or (3) an extended heat treatment. Knoop hardness values were determined. Results indicated that the Knoop hardness of cast titanium was less than that of the cast titanium standard treatment group, which was less than the Knoop hardness of the cast titanium extended treatment group. Knoop hardness of milled titanium was less than that of the milled titanium standard treatment and milled titanium extended treatment groups. For the surface hardness profile, cast titanium showed a decreasing surface hardness as the distance from the surface of the specimen increased. No such trend was identified for the other groups tested.

Chromium Alloys↗

Corrosion of titanium and amalgam couples: effect of fluoride, area size, surface preparation and fabrication procedures.

OBJECTIVES: The aim of this investigation was to study the effect of surface treatments and electrode area size on the corrosion of cast and machined titanium in contact with conventional and high-copper amalgams in saline solutions with and without added fluoride ions. METHODS: The potentials and the charges transferred between amalgam and titanium couples were registered using standard electrochemical methods. RESULTS: Conventional amalgam corroded more than high-copper amalgams in contact with titanium in saline solutions. Adding fluoride to the solution made the titanium potential more active and enhanced the corrosion of titanium in combination with high-copper amalgams. The amalgam corrosion increased with a five-fold enlargement of the titanium area. The increase was significant for one titanium-amalgam combination. Surface preparations affected the electrochemical behavior, and surface alterations were occasionally observed on wet-ground titanium specimens. No significant differences were found in comparisons of cast and lathe-cut titanium. SIGNIFICANCE: Surface preparations and fluoride affect the electrochemical activity of titanium.

Copper↗

Polysaccharide-protein surface modification of titanium via a layer-by-layer technique: characterization and cell behaviour aspects.

To improve the surface biocompatibility of titanium films, a layer-by-layer (LBL) self-assembly technique, based on the polyelectrolyte-mediated electrostatic adsorption of chitosan (Chi) and gelatin (Gel), was used leading to the formation of multilayers on the titanium thin film surfaces. The film growth was initialized by deposition of one layer of positively charged poly(ethylene imine) (PEI). Then the thin film was formed by the alternate deposition of negatively charged Gel and positively charged Chi utilizing electrostatic interactions. The LBL film growth was monitored by several techniques. The chemical composition, surface topography as well as wettability were investigated by using X-ray photoelectron spectroscopy (XPS), atomic force microscopy (AFM), confocal laser scanning microscopy (CLSM) and water contact angle measurement, respectively. Quantitative XPS analysis showed the alternative change of C/N ratio after four sequential cycles coating of Ti/PEI/Gel/Chi/Gel, which indicated the discrete layer structure of coatings. Uncoated titanium (control sample) displayed a smooth surface morphology (root mean square (RMS) roughness was around 2.5 nm). A full coverage of coating with Gel/Chi layers was achieved on the titanium surface only after the deposition layers of PEI/(Gel/Chi)2. The PEI/Gel/(Chi/Gel)3 layer displayed a rough surface morphology with a tree-like structure (RMS roughness is around 82 nm). These results showed that titanium films could be modified with Chi/Gel which may affect the biocompatibility of the modified titanium films. To confirm this hypothesis, cell proliferation and cell viability of osteoblasts on LBL-modified titanium films as well as control samples were investigated in vitro. The proliferation of osteoblasts on modified titanium films was found to be greater than that on control (p<0.05) after 1 and 7 days culture, respectively. Cell viability measurement showed that the Chi/Gel-modified films have higher cell viability (p<0.05) than the control. These data suggest that Chi/Gel were successfully employed to surface engineer titanium via LBL technique, and enhanced its cell biocompatibility. The approach presented here may be exploited for fabrication of titanium-based implant surfaces.

Adsorption↗

[High incidence of total hip arthroplasty aseptic loosening with ion-coated titanium femoral heads].

PURPOSE OF THE STUDY: The purpose of this study was to determine the frequency of aseptic loosening among a series of total hip arthroplasties evaluated at 84 months and to search for the cause. Two types of acetabular cups had been implanted. It was hypothesized that the ion coating of the titanium head could be involved in the deterioration of titanium/polyethylene implants. MATERIAL AND METHODS: Two non-cemented acetabular cups differing only by the presence or not of a hypoxyapatite coating were studied. Different types of femoral heads (stainless steal, chromium-cobalt, alumina, zincrona, nitrurated titanium, ion-coated titanium) and femoral stems (with or without cement) were implanted. Sixty-two ion-coated titanium heads were implanted and 47 patients with 52 heads were reviewed. Clinical outcome was assessed with the Postel-Merle-d'Aubigné score and the Livermoore method was used for radiological assessment of the bone-implant interface and polyethylene wear. The physico-chemical properties of one titanium head explanted after aseptic loosening were also studied. RESULTS: At 84 months follow-up, the mean clinical score was 15.8/18 points. Mean polyethylene wear was 0.18 mm/year. There were 13 revisions for aseptic loosening: two bipolar, nine acetabular and two femoral. Mean wear for the explanted implants was 0.34 mm/year. Metallosis was observed in eight cases. Arthroplasties with the same types of femoral stem and acetabular implants but with other types of heads (stainless steal, chromium-cobalt, alumina, zincrona, nitrurated titanium) led to only one case of aseptic loosening among 118 implantations. Electron microscopy demonstrated the presence of scratch lines, disappearance of the nitrogen ion layer, decreased hardness, and increased roughness of the titanium head. DISCUSSION: The poor friction properties of titanium are well known. To improve performance, ion coating has been proposed. This technique consists in projecting nitrogen ions onto the surface of the head to form a surface coating measuring about one micron. The high incidence of aseptic loosening, polyethylene wear, metallosis, and modifications of the head surface (disappearance of the nitrogen ion layer, scratch marks, etc.) suggest ion-coated titanium heads could be the cause of these aseptic loosenings. CONCLUSION: Ion-coating has not provided good protection of the titanium head. Patients with this type of head should be followed carefully in order to detect aseptic loosening or metallosis early.

Adult↗