Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Size”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12Linked to original sources

Required minimum granule size in UASB reactor and characteristics variation with size.

The objective of this study was to define minimum size of bioparticles that could be classified as granules, to offer all advantages of granular sludge. Based on the theory of sedimentation, the minimum diameter bioparticles, which should be considered as granules was found out for specific gravity of sludge ranging between 1.01 and 1.05. For example, for specific gravity of 1.035 the minimum diameter of granules required for better sludge retention was 0.34 mm. The diameter based on this theory was evaluated by carrying out settling column analysis of a granular sludge obtained from lab-scale UASB reactor and verified with microscopic observation. To find out the effect of granules size on the nature of biodegradability, specific methanogenic activity (SMA) was carried out. It was observed that SMA increased with size of bioparticles tested in the range of 0.27-3.03 mm. The change in VSS/SS ratio and specific gravity was observed with size of granules. Consideration of variation in specific gravity with size of granules increased the degree of validation of sedimentation theory for the calculation of granules diameter.

Biodegradation, Environmental↗

The effect of droplet size and powder particle size on the mechanisms of nucleation and growth in fluid bed melt agglomeration.

This study was performed in order to evaluate the effects of binder droplet size and powder particle size on agglomerate formation and growth in fluid bed spray agglomeration using a meltable binder. Three different lactose grades, 100, 125 or 350 mesh, were agglomerated using polyethylene glycol (PEG) 3000 at two different concentrations, 11.5 or 22% (volume/mass), and three spray droplet sizes, 30, 60 or 90 microm were applied. The ratio of droplet size/particle size was found to determine whether the mechanism of nucleation was distribution or immersion. Distribution was promoted by a low ratio, whereas immersion was promoted by a high ratio. Distribution as nucleation mechanism led to a more open agglomerate structure and immersion to a denser structure. When the nucleation phase was terminated, coalescence between rewetted nuclei or agglomerates was the growth mechanism with both preceding mechanisms of nucleation. A larger particle size of the lactose led to larger agglomerates. The difference in the effect on growth between the 30 and 60 microm droplets was generally low. The 90 microm droplets at 22% binder concentration offered a potential for uncontrollable growth giving rise to markedly larger agglomerates and a lower reproducibility than 30 and 60 microm droplets.

Particle Size↗

Visual search for size-defined target objects is modulated by the Ebbinghaus apparent-size illusion: facilitatory and inhibitory effects of the context objects.

Five experiments were carried out to investigate under which conditions the apparent size of objects is computed and exploited optimally in visual search for size-defined targets. Observers searched for a target test circle that was retinally larger than the distractor test circles, with both types of circles surrounded by context circles modulating the apparent size of the test circles (Ebbinghaus illusion). RTs were the faster the better test circles could be differentiated from the context circles, ie with smaller numbers of context circles, larger distances, and higher lightness (or colour) contrast between test and context circles. Apparent-size modulation had a strong influence on search RTs, resulting in faster RTs with smaller, and slower RTs with larger, context circles. A model assuming overall facilitatory effects of the apparent-size modulation and interference effects arising from decreasing test-context circle discriminability can explain the present results.

Adult↗

A chemometrics method for separation of size dependent and size independent attributes of microspheres for medical ultrasound imaging.

The size dependent and size independent contributions to the mechanical properties of poly(ethyleneglycol) microspheres with encapsulated air, made for medical ultrasound imaging, have been studied. A relation between the size of microspheres in a reference group and their acoustic attenuation efficacy was derived by partial least square regression. The developed model was used to estimate acoustic attenuation as a function of the measured size distribution for various preparations made during formulation and process studies. The ratio between the measured attenuation and model estimated attenuation was then used to evaluate variations in the mechanical properties of the polymer shell and the contribution of such variations to the acoustical properties of the substance. The statistical parameter was compared with results for the mechanical compressibility derived from a theoretical approach and the results from the two methods mutually confirmed each other. The statistical procedure outlined has been found applicable for studies of other particulate products with size dependent in vitro or in vivo properties.

Acoustics↗

Reducing liposome size with ultrasound: bimodal size distributions.

Sonication is a simple method for reducing the size of liposomes. We report the size distributions of liposomes as a function of sonication time using three different techniques. Liposomes, mildly sonicated for just 30 sec, had bimodal distributions when surface-weighted with modes at about 140 and 750 nm. With extended sonication, the size distribution remains bimodal but the average diameter of each population decreases and the smaller population becomes more numerous. Independent measurements of liposome size using Dynamic Light Scattering (DLS), transmission electron microscopy (TEM), and the nystatin/ergosterol fusion assay all gave consistent results. The bimodal distribution (even when number-weighted) differs from the Weibull distribution commonly observed for liposomes sonicated at high powers over long periods of time and suggests that a different mechanism may be involved in mild sonication. The observations are consistent with the following mechanism for decreasing liposome size. During ultrasonic irradiation, cavitation, caused by oscillating microbubbles, produces shear fields. Large liposomes that enter these fields form long tube-like appendages that can pinch-off into smaller liposomes. This proposed mechanism is consistent with colloidal theory and the observed behavior of liposomes in shear fields.

Light↗

Size analysis of a pressurized metered dose inhaler-delivered suspension formulation by the API Aerosizer time-of-flight aerodynamic particle size analyzer.

Aerosizer time-of-flight (TOF) aerodynamic particle size analyzers (TSI-Amherst, Amherst, MA) are widely used for the rapid assessment of aerosols from a wide variety of drug delivery devices, including pressurized metered dose inhalers (pMDIs). This technique offers significant advantages in terms of rapid measurement times in comparison with the more time-consuming compendial methods such as the cascade impactor or multistage liquid impinger. Particle size analysis takes place by determining the TOF of individual particles following acceleration to supersonic velocity. No drug assay is performed; thus, the resulting size distribution also includes particles that do not contain any medication such as the excipients and surfactant that are present in most pMDI-based formulations. Illustrative data are presented for one particular formulation (Pulmicort: 200 micrograms of budesonide per dose; Astra Draco; Lund, Sweden) and demonstrate that bias from this source can significantly shift the reported particle distribution to finer sizes compared with impactor-based analysis in which direct assay for drug has taken place. In this case, the mass median aerodynamic diameter (MMAD) determined by an Aerosizer-LD was close to 2.4 microns, but was found to be approximately 4 microns using the cascade impactor-based procedure. Such a shift results in an overestimation of the fine particle fraction of the emitted dose, which may lead to misleading conclusions about the therapeutic benefit of a particular drug delivery system when making use of this formulation. TOF aerosol measurement techniques appear to be vulnerable to this type of bias for any suspension formulation in which the drug content is not homogeneously distributed within all particle sizes.

Bronchodilator Agents↗

Effects of surface charge, micro-bubble size and particle size on removal efficiency of electro-flotation.

Flotation is a water treatment alternative to sedimentation, and uses small bubbles to remove low-density particles from potable water and wastewater. The effect of zeta potential, bubble size and particle size on removal efficiency of the electro-flotation process was investigated because previous model-simulations indicated that these attributes are critical for high collision efficiency between micro-bubbles and particles. Solutions containing Al3+ as the metal ion were subjected to various conditions. The zeta potentials of bubbles and particles were similar under identical conditions, and their charges were influenced by metal ion concentration and pH. Maximum removal efficiency was 98 and 12% in the presence and absence of flocculation, respectively. Removal efficiency was higher when particle size was similar to bubble size. These results agree with modelling simulations and indicate that collision efficiency is greater when the zeta potential of one is negative and that of the other is positive and when their sizes are similar.

Aluminum Chloride↗

The Ebbinghaus illusion modulates visual search for size-defined targets: evidence for preattentive processing of apparent object size.

Five search experiments investigated whether the apparent size of objects is, like their retinal size, coded in preattentive vision. Observers searched for a target circle that was either larger or smaller than distractor circles, with both types of test circles surrounded by context circles modulating apparent size (i.e., the Ebbinghaus illusion). The size ratio between the test and the context circles was manipulated in such a way that the test circles were surrounded by, for example, smaller context circles (making the larger target appear even larger) or by larger context circles (making the smaller distractors appear even smaller). Under optimal conditions, the detection reaction times were independent of the number of test circles in the display, and the Ebbinghaus illusion facilitated the detection of the target even in comparison with control conditions without any context circles. This finding is consistent with preattentive, spatially parallel processing of apparent size.

Adult↗

Laparoscopic splenectomy in patients with normal-sized spleens versus splenomegaly: does size matter?

Laparoscopic resection has become the standard means for removal of normal-sized spleens in many medical centers. The application of minimally invasive techniques in the setting of splenomegaly is less well defined and was previously considered a contraindication to the laparoscopic approach. The purpose of this prospective study of consecutive patients was to compare the outcomes of patients undergoing laparoscopic splenectomy for normal-sized spleens (150 g or less) versus those with clear evidence of splenomegaly (500 g or greater). One hundred forty-two patients met the inclusion criteria. The most common diagnosis in the normal-sized spleen group was idiopathic thrombocytopenia purpura (67 of 82, 82%). Malignant hematologic diseases (lymphoma and leukemia) were the most common diagnoses in the splenomegaly group (35 of 60, 58%). Mean operative times (127 vs 172 minutes) and estimated blood loss (123 vs 173 cm3) were lower for those patients with normal-sized spleens (P < 0.05). There were no statistical differences in conversion rates, lengths of stay, or complications between the two groups. We conclude that laparoscopic splenectomy is safe and effective in the setting of splenomegaly despite modest but statistically longer operative times and increased operative blood loss when compared with laparoscopic splenectomy for normal-sized spleens.

Adolescent↗

The impact of training, food type, gender, and container size on the estimation of food portion sizes.

Students in a large introductory nutrition course were divided into two groups, one that received training on estimating food quantities and one that received no instruction. Training consisted of 10-minute sessions in which 76 subjects (in groups of 10) passed around and viewed food models labeled with their portion sizes while one of the investigators verbally indicated the quantities. Immediately following instruction, the trained subjects individually estimated portion sizes of one of four displays of six foods: two solids (meat loaf and fish), two liquids (milk and soup), and two amorphous items (spaghetti and apple sauce). The second group of subjects, who had received no training, also estimated the same portion sizes of the same foods in the same displays. The four displays were set up in separate rooms, with the same foods and portion sizes in each, but different container size combinations were used (smaller vs. larger containers). Both training and type of food had a significant effect; training improved estimations, and, in general, solids were better estimated than liquids, which were better estimated than amorphous items. Although results were mixed, women tended to estimate more accurately than men. There was some tendency for estimates to be more accurate when made for foods in small containers. The authors conclude that a training session enhances the accuracy of individuals estimating food quantity and that accuracy of estimates differs for different food types.

Analysis of Variance↗

Scaling of growth and life history traits relative to body size, brain size, and metabolic rate in lorises and galagos (Lorisidae, primates).

A broad range of variation in body size, brain size, and metabolic rate occurs within the primate family Lorisidae, thus providing an opportunity to examine the relationship of these three parameters to variation in growth and life history traits. Data on adult body weight, gestation length, lactation length, age at first estrus, litter size, and growth parameters were collected from a captive colony of four lorisid species, Loris tardigradus, Nycticebus coucang, Galago crassicaudatus, and G. senegalensis. The data presented here constitute the most complete life history information available for these poorly understood prosimian species. Correlation and allometric analyses were performed to determine the relationships between variables. Among the lorisids studied, adult body weight, adult cranial capacity, and relative cranial capacity did not predict variation in life history traits. Adult basal metabolic rate predicted most of the variability in gestation length, lactation length, and growth parameters. Lorisines differ from similarly sized galagines in having lower basal metabolic rates, slower growth rates, slower developmental rates, and smaller litter sizes, resulting in reduced reproductive potential. This may be a consequence of lorisine adaptation to a diet of toxic insects. Metabolic rate and diet may be among the most important parameters to examine in any study of life history evolution.

Animals↗

Femoral component sizing in total knee arthroplasty: size matched resection versus flexion space balancing.

Generally, 2 different methods are used to select femoral size. These can be termed "size-matched resection" and "flexion-space balancing." The purpose of this paper is to compare these 2 methods during 50 sequential total knee arthroplasty surgeries. The flexion-space-balancing method led to a smaller size selection than the size-matched-resection method in 28 (56%) knees. In the remaining 22 knees, the measurement methods led to the selection of the same size femoral component. The difference in measurement methods was significant (P<.05). The preoperative varus knees were more sensitive to the differences in measurement methods than the valgus knees (P<.05). A flexion space that is too small may adversely affect the clinical outcome of knee arthroplasty.

Arthroplasty, Replacement, Knee↗

Genome size is negatively correlated with effective population size in ray-finned fish.

A recent theory suggesting that genome size and complexity can increase as a passive consequence of small effective population size has generated much controversy. In this article, we demonstrate that freshwater fish species, which have smaller effective population sizes than marine fish species, have larger genomes. We show that genome size is negatively correlated with genetic variability, independent of phylogeny, body size and generation time. Genome duplication is also observed predominantly in freshwater fish. These results suggest that the raw materials of complexity originate under conditions of reduced selection efficiency.

Animals↗

Monolithic silica columns with various skeleton sizes and through-pore sizes for capillary liquid chromatography.

Reduction of through-pore size and skeleton size of a monolithic silica column was attempted to provide high separation efficiency in a short time. Monolithic silica columns were prepared to have various sizes of skeletons (approximately 1-2 microm) and through-pores (approximately 2-8 microm) in a fused-silica capillary (50-200 microm I.D.). The columns were evaluated in HPLC after derivatization to C18 phase. It was possible to prepare monolithic silica structures in capillaries of up to 200 microm I.D. from a mixture of tetramethoxysilane and methyltrimethoxysilane. As expected, a monolithic silica column with smaller domain size showed higher column efficiency and higher pressure drop. High external porosity (> 80%) and large through-pores resulted in high permeability (K = 8 x 10(-14) -1.3 x 10(-12) m2) that was 2-30 times higher than that of a column packed with 5-mirom silica particles. The monolithic silica columns prepared in capillaries produced a plate height of about 8-12 microm with an 80% aqueous acetonitrile mobile phase at a linear velocity of 1 mm/s. Separation impedance, E, was found to be as low as 100 under optimum conditions, a value about an order of magnitude lower than reported for conventional columns packed with 5-microm particles. Although a column with smaller domain size generally resulted in higher separation impedance and the lower total performance, the monolithic silica columns showed performance beyond the limit of conventional particle-packed columns under pressure-driven conditions.

Chromatography, Liquid↗

Size-related and size-unrelated functional heterogeneity among pancreatic islets.

Functional heterogeneity of pancreatic islets was systematically analyzed for the first time using freshly isolated single rat pancreatic islets. First, 60 islets were sequentially exposed to 3, 9.4, 15.6, and 24.1 mM glucose for 30 min each in incubation experiments: 36 (60%) responded in a concentration-dependent and 19 (32%) in an all-or-none manner, and 5 (8%) islets did not respond to high glucose. As a group, the larger the islet, the higher the beta cell glucose sensitivity. However, glucose-stimulated elevation of [Ca2+]i in the beta cell. insulin/glucagon ratio in the islet, and expression of glucose transporter 2, glucokinase, and pancreatic duodenal homeobox factor-1 in the beta cell were not significantly related to islet size. Second, 50 islets were stimulated with 16.7 mM glucose in perifusion. A biphasic insulin release was found in 39 (78%), and no or little first phase response in 11 (22%) islets, irrespective of the islet size. Nevertheless, when the response was plotted as a group, it was clearly biphasic. Islet size, insulin content and the amount of insulin release were positively correlated with each other. In conclusion, there are size-related and size-unrelated functional diversity among pancreatic islets. The reason for such heterogeneity remained to be determined.

Animals↗

The size of sebaceous glands in relation to the size of hair follicles on the heads of some small mammals (Insectivora, Chiroptera, Rodentia).

Many large sebaceous glands have been described, and functions such as scent production suggested, but gland size has seldom been studied in relation to the surface area of their hair follicles. However, investigating this relationship is essential for establishing whether glands produce more sebum than would be required for lubricating associated hair alone. Here, the relationship between sebaceous gland size and the surface area of the associated hair follicles has been studied. Glands on the heads of 20 species from three orders were compared with those associated with fur hairs. In all species, the fur hairs had small hair follicles with small sebaceous glands, as had the mystacial and submandibular hairs of Rodentia. Medium-sized glands and hairs were found in the mystacial and submandibular region in Insectivora, and in the circumoral region in Chiroptera and Rodentia. Large glands and hairs were found on a pad in the corner of the mouth in Rodentia. Although the size of glands was not directly proportional to hair size, some gross trends were noted. Vibrissae had either no or very small sebaceous glands. It is likely that sebum has to be provided from elsewhere to lubricate their surfaces. The glands on the snout of Insectivora and Chiroptera are clearly enlarged and could probably produce more sebum than would be required for grooming vibrissae alone. In Rodentia, vibrissae were surrounded by small hair and glands, and the nearest glands large enough to provide sebum were the glands on the pad in the mouth corner.

Animals↗

Size-dependent properties of nanocrystalline silicalite synthesized with systematically varied crystal sizes.

Silicalite-1 powders with crystal sizes ranging from 20 to 1000 nm were synthesized by systematically varying synthesis gel composition, pressure, temperature, and time duration. These samples were characterized by powder X-ray diffraction, scanning electron microscopy, nitrogen adsorption isotherms, solid-state nuclear magnetic resonance, and toluene adsorption. The effect of crystal size on the physical properties of crystals is observed, including a large increase of both total and external surface area when crystal size decreases. The relationship between particle size and external surface area was modeled by assuming a cubic crystal geometry. The nanosized silicalite samples with crystal sizes less than 100 nm have a higher adsorption capacity for toluene, showing promising potential for its application in volatile organic compound removal.

Journal Article↗

The use of gel chromatography for the determination of sizes and relative molecular masses of proteins. Interpretation of calibration curves in terms of gel-pore-size distribution.

The separation of proteins by gel-exclusion chromatography has been explained in terms of partitioning of the macromolecules within the gel by a distribution of pores of various radii. The assumption that the distribution of pore sizes is Gaussian has led to the prediction of a linear relationship between the molecular Stokes radius (RS) of the protein and the function erf-1 (1-KD), where KD is the partition coefficient [Ackers (1967) J. Biol. Chem. 242, 3237-3238]. Since careful calibrations of classical (agarose and dextran) gels and h.p.l.c. gels have shown that such a linear relationship is not verified experimentally over a wide range of native protein sizes, we have reinvestigated the model of Ackers (above reference). We show that Ackers' (above reference) derivation is not valid except for a particular Gaussian distribution of pore sizes centred at the origin. Relaxation of this restriction to allow for other types of Gaussian distributions cannot account for the non-linear calibration curves that we have obtained. Instead we show that the pore-size distribution can be calculated from the experimentally determined function KD = f(RS) and that this distribution is bimodal (non-Gaussian). One distribution is centred below 2 nm, whereas the mean value of the second one is around 6-8 nm. The minimum in this bimodal distribution corresponds, for some gels, to a region of poor resolution, which needs to be appreciated for the proper use of gel chromatography in the determination of molecular size.

Chromatography, Gel↗