Syringe pumped high speed flow cytometry of oceanic phytoplankton.

BACKGROUND: Nanophytoplankton (2-20 microm) are less numerous than picophytoplankton (<2 microm) in the oceans but their biomass and production are comparable and sometimes higher. The accuracy of cytometry-based enumeration of phytoplankton ultimately depends on cell abundance and sample flow rate. Commercial flow cytometers in which sheath and core streams are driven by air pressure cannot produce sufficiently high, stable sample flow rate. The present study demonstrates the applicability of a syringe pump for flow cytometric enumeration of oceanic nanophytoplankton on two meridional transects across the Atlantic Ocean. METHODS: Commercially available syringe pumps were used to deliver live phytoplankton samples into a flow cell of standard flow cytometers (FACSort, FACSCalibur, BD) with increased flow rate of > 1.0 ml min(-) (1) compared to the normal air pressure sample delivery of < 0.1 ml min(-) (1). An auxiliary application of syringe pump flow cytometry for calibrating 0.5 microm bead concentration standards is also discussed. RESULTS: The results demonstrated that flow cytometry of samples injected at rates above 0.1 ml min(-) (1) is achievable and worthwhile. Counts of phytoplankton in air and syringe pumped samples agreed closely. Syringe pumping of samples offered a broader range of flow rates up to 0.8-1.0 ml min(-) (1) without detrimental effect on flow cytometric enumeration of cells. The increased number of coincidences at high flow rates led to an approximate 10% decrease of Cyanobacteria counts when the acquisition rate approached 1,000 particles s(-) (1), but seemed to have a lesser effect on counting rarer phytoplankton. The syringe pump flow cytometry allowed enumeration of phytoplankton groups at concentrations of 5-100 cells ml(-) (1), cell concentrations equivalent to those of Cyanobacteria in the twilight deep ocean. CONCLUSION: The proposed syringe pump modification of a FACS instrument represents a significant improvement for accurate enumeration of the less abundant phytoplankton and so gives better estimations of phytoplankton distribution and standing stocks.

Atlantic Ocean↗

Loss of resistance technique for locating the epidural space: evaluation of glass and plastic syringes.

Location of the epidural space in epidural anaesthesia usually involves the measurement of loss of resistance using glass or plastic syringes. In the present study two varieties of glass syringe and one plastic type were evaluated to determine the resistive forces associated with plunger movement. The mean static (fs) and dynamic (fd) forces for polished glass syringes having a ground plunger only were fs = 0.47 X 10(-3) +/- 0.22 X 10(-3) N and fd = 0.37 X 10(-3) +/- 0.19 X 10(-3) N and for polished glass syringes having a ground barrel and plunger were fs = 0.43 X 10(-3) +/- 0.16 X 10(-3) N and fd = 0.38 X 10(-3) +/- 0.15 X 10(-3) N. Each of these values was significantly lower (P less than 0.5) than those for plastic syringes fs = 2.22 X 10(-3) +/- 0.48 X 10(-3) N and fd = 1.46 X 10(-3) +/- 0.37 X 10(-3) N. It is concluded that glass syringes are favoured over plastic for locating the epidural space because frictional forces developed with glass syringes were significantly lower than with plastic.

Anesthesia, Epidural↗

Are peristaltic pumps as reliable as syringe pumps for metabolic research? Assessment of accuracy, precision, and metabolic kinetics.

Syringe pumps are traditionally used to infuse tracers in metabolic research because they are perceived to be more accurate and precise than peristaltic pumps. This study evaluated the accuracy (actual v programmed infusion rate) and precision (reproducibility of infusion) of a peristaltic pump (Gemini PC 2; IMED, San Diego, CA) and a syringe pump (Model 22; Harvard Apparatus, Natick, MA) for metabolic research. In one protocol, saline delivery was measured in vitro in 5 trials at 4 flow rates: 3, 30, 150, and 300 mL/h. In the second protocol, basal glycerol rate of appearance (Ra) was determined in vivo in 5 women on 2 consecutive days. On day 1, [2-(13C)]glycerol was infused with 1 pump and [1,1,2,3,3-(2H5)]glycerol with the other. On day 2, the opposite pattern was used. The accuracy of the 2 pumps was the same (error approximately 2%). In addition, both the syringe and the peristaltic pumps were very precise, with coefficients of variation (CV) <1% at all flow rates. Glycerol Ra values were the same when tracer was infused with either a syringe or peristaltic pump on day 1 and day 2: 4.1 +/- 1.7 (syringe pump) and 4.2 +/- 1.9 (peristaltic pump) micromol. kg fat mass (FM)(-1). min(-1) on day 1; 4.2 +/- 1.2 (syringe pump) and 4.2 +/- 1.3 (peristaltic pump) micromol. kg FM(-1). min(-1) on day 2. These data demonstrate that both syringe and peristaltic pumps are very accurate and precise across a large range of flow rates. Moreover, the assessment of in vivo substrate kinetics in human subjects is the same when either pump is used to infuse isotope tracers.

Adult↗

Injection pain and postinjection pain of the anterior middle superior alveolar injection administered with the Wand or conventional syringe.

OBJECTIVE: The purpose of this prospective, randomized, blinded study was to compare the pain of injection and post-injection pain of the AMSA injection using the computer-assisted Wand Plus injection system versus a conventional syringe. STUDY DESIGN: Using a crossover design, 40 subjects randomly received 2 blinded AMSA injections using the Wand Plus system and a conventional syringe, at 2 separate appointments. The AMSA injection site was centered halfway between the midpalatine raphe and gingival margin of the first and second premolars. The pain of needle insertion, anesthetic solution deposition pain, and postinjection pain were recorded on a Heft-Parker VAS for the 2 AMSA injections. RESULTS: For needle insertion, 38% of the subjects had moderate/severe pain with the Wand Plus((R)) and 34% moderate/severe pain with the conventional syringe, with no significant difference between techniques. There was a significant difference for solution deposition pain, with the conventional syringe causing more moderate/severe pain (42% conventional vs. 25% for the Wand Plus. Regarding postinjection pain, after numbness wore off there was no significant difference between the Wand Plus injection technique (0% moderate pain) and the conventional syringe technique (8% moderate pain). Postinjection, approximately 8% to 10% of the subjects experienced slight palatal swelling and 2% experienced temporary numbness. These problems resolved quickly and were considered minor. CONCLUSIONS: The AMSA injection, using the Wand Plus, resulted in similar pain ratings for needle insertion as the conventional syringe but statistically lower pain ratings upon anesthetic solution deposition. However, the AMSA, using either the Wand Plus or a conventional syringe, has the potential to be a painful injection. We found the incidence of postinjection pain and sequelae was low with both techniques.

Adult↗

Safety and immunogenicity of an Haemophilus influenzae type b-tetanus toxoid conjugate (PRP-T) and diphtheria-tetanus-pertussis (DTP) combination vaccine administered in a dual-chamber syringe to infants in Belgium and Chile.

To document any unexpected differences in the immune response between study populations and to evaluate immunogenicity and safety of a simplified presentation (dual-chamber syringe) of an Haemophilus influenzae type b-tetanus toxoid conjugate (PRP-T) and diphtheria-tetanus-pertussis (DTP) combination vaccine, a multicentre, randomized, comparative study was conducted in Belgium and Chile. A total of 537 healthy infants, 270 in Chile and 267 in Belgium, received PRP-T and DTP vaccines combined in a dual-chamber syringe (D-Ch group, DTP/PRP-T, reconstituted by pressing the plunger of the syringe immediately before injection, n = 239) or combined in a single-chamber syringe (C-In group, DTP@PRP-T, reconstituted immediately before injection, n = 61) or in separate injections (S-In group, DTP + PRP-T, simultaneously injected at separate sites, n = 237) at 3, 4, and 5 months of age. Serum samples were collected before vaccination and at 6 months of age. In the D-Ch group, the incidence of adverse events was comparable to administration of DTP vaccine alone. Higher rates of local and systemic reactions were observed in the Chilean population, possibly due to differences in surveillance practice. The immune response to each vaccine component compared well to that of the separate administration of PRP-T and DTP vaccines, except for higher post-immunization anti-PRP geometric mean titre (GMT) values after separate injections (25.6 micrograms mL-1) than after combined injection with the dual-chamber syringe (17.6 micrograms mL-1) (p = 0.001). An unexpected 'syringe' effect was seen: a greater post-immunization anti-PRP GMT was observed in the D-Ch group (17.6 micrograms mL-1) than in the C-In group (7.7 micrograms mL-1) (p = 0.0001). Whereas pre-immunization GMTs of some antibodies were significantly lower in Chilean than in Belgian infants, the post-immunization GMTs of Chilean infants were two to three times greater for all of the antibodies studied (p < 0.005). Differences in reactogenicity and in the immune response between the study populations or the different vaccine presentations were striking, but are probably of no clinical relevance. The convenient dual-chamber syringe presentation of DTP and PRP-T vaccines is safe and highly immunogenic.

Antibodies, Bacterial↗

Syringe type and drug injector risk for HIV infection: a case study in Texas.

Studies of accidental needlestick exposure to blood containing human immunodeficiency virus (HIV) have shown that the volume of blood in an exposure is a strong predictor of subsequent infection. Illicit drug injectors, a group at elevated risk for HIV transmission, use syringes manufactured in two styles, one of which (the integral cannula type) retains substantially less blood after intravenous use than the other (the detachable needle type). In this report, we examine some of the factors associated with use of syringes with detachable needles among drug injectors in San Antonio, Texas using data from epidemiological surveys, ethnographic studies, and historical observations. We compare personal history of syringe type use with HIV serostatus in a sample of 501 active drug injectors interviewed and screened for HIV in 1997-1998. Ninety-nine percent of these respondents reported that they currently used only integral cannula syringes, but 13% had used a syringe with a detachable needle within the past 2 years, and 37% had used one in their lifetime. Only 9% had ever used one > or = 20 times in a year. Hispanic (Mexican American) respondents were significantly less likely than other ethnic groups to have ever used a detachable needle syringe. HIV seroprevalence was < 1% among heterosexual injectors who had never used a detachable needle syringe compared to 4% among those who had used one (p<0.05).

Adolescent↗

Aseptic efficacy of prefilled syringes in a polluted environment.

INTRODUCTION: To evaluate the aseptic efficacy of prefilled syringes compared with ampules when used in a polluted environment similar to that at a disaster site. METHODS: The researchers tested epinephrine, 0.1%, atropine sulfate, 0.05%, and lidocaine hydrochloride solutions, 2% (Group A) as well as lidocaine hydrochloride, 10%, sodium bicarbonate, 8.4%, and glucose solutions, 50% (Group B), that frequently are used for intravenous injection and intravenous infusion respectively in Disaster Medicine. Each of these solutions in 10 prefilled syringes (PFSs) and 10 ampules was placed in a box of contaminated soil along with needles and empty syringes for ampules. In the box, each was taken out of its package, all syringes were connected with a needle, and empty syringes were filled with a solution. After this procedure, all syringes were taken out of the box to check their contents for bacterial contamination. RESULTS: No bacterium was observed in any of the 10 PFS samples of Group A and B solutions. In contrast, out of 10 ampule samples, six of the 10 samples containing epinephrine, nine of the 10 containing atropine sulfate, all 10 samples containing lidocaine hydrochloride, 2%, and all of the ampule samples containing Group B solutions tested positive for bacteria. A statistically significant difference was observed between the PFS and ampule samples in all six solutions. CONCLUSION: Results indicate that, in environments with airborne contaminants, the use of prefilled syringes may be useful for preventing bacterial contamination of the medicine inside.

Air Microbiology↗

Modified syringe design prevents plunger-related contamination--results of contamination and flow-rate tests.

The usual mechanism for syringe contamination is spread of micro-organisms along the inside of the barrel. Two or more full strokes of the plunger will inevitably transport a contaminant from the inside wall into the sterile compartment. We modified syringes by replacing the plunger with a modified version that has an additional central O-ring seal. Conventional and modified syringes were tested for their susceptibility to contamination using standard microbiological and radioisotope methods, and the flow-rate stability of the modified syringe design was assessed in a model with commercially available infusion pumps. Although conventional syringes consistently became contaminated with the second full excursion of the plunger, no contamination was observed in modified syringes, even after 100 aspiration/injection cycles. With respect to flow-rate stability, the new syringe design complies with DIN (German Institute for Standardization) standards.

Cross Infection↗

Evaluation of a filter-syringe set for preparation of packed cell aliquots for neonatal transfusion.

A closed-system filter-syringe set designed for preparation of prefiltered aliquots of packed red cells for neonatal transfusion was evaluated. In three experiments, filter-syringe sets were sterile-connected, and aliquots were prepared at six intervals during 35-day storage of CPDA-1 packed cells. Hemoglobin (HGB), supernatant potassium (K+), and free hemoglobin (fHGB) in the aliquot and primary storage container were compared. There was no tubing weld failure, filter-occlusion, or bacterial contamination of the units. Hemoglobin remained stable over 35 days of storage, with comparable values in the primary collection container and syringe aliquot. Supernatant potassium in the units increased to an average of 89.5 mEq/L at 35 days, and levels in the aliquots closely matched those in the primary containers at each storage interval (maximum average 91.8 mEq/L). Free hemoglobin also progressively and comparably increased in both the primary containers and syringe aliquots. The gentle negative pressure and turbulence during use of the filter-syringe set apparently causes little hemolysis. The set simplifies preparation of aliquots for neonatal small volume and syringe-pump transfusion at costs comparable to alternative preparation methods. When sterile-connected, the filter-syringe set facilitates "assigned unit" inventory management for neonatal transfusion, which has been shown to be highly effective in limiting donor exposures.

Erythrocyte Transfusion↗

Accuracy of technicians versus pharmacists in checking syringes prepared for a dialysis program.

The accuracy of pharmacy technicians versus pharmacists in checking drug doses prepared in syringes for a dialysis program was studied. Three pharmacy technicians from the pharmacy of a regional kidney disease program in Minnesota participated in the study after completing a training program and after common preparation errors had been identified by pharmacists. From November 1995 to April 1996, the technicians used labels printed from a database of pharmacist-verified orders to prepare and label i.v. syringes. Four medications were used-epoetin alfa, calcitriol, heparin prepared from beef lung, and heparin prepared from porcine intestinal mucosa. Each syringe was checked by one of nine pharmacists for accuracy of dose and medication, and all errors were recorded. The technicians checked syringes prepared by other technicians and also recorded errors. Accuracy rates (percentages of syringes correctly evaluated) for pharmacists and technicians were compared. A total of 10,608 syringes were checked. Accuracy rates for pharmacists and pharmacy technicians were 99.86% and 99.83%, respectively. Accuracy rates in checking syringes did not differ significantly between pharmacists and technicians in this study setting.

Chi-Square Distribution↗

Stability of reconstituted indomethacin sodium trihydrate in original vials and polypropylene syringes.

The stability of reconstituted indomethacin sodium trihydrate 0.5 mg/mL in sterile water for injection for 14 days at either 2-6 degrees C or room temperature (21-25 degrees C) in the drug's original vial and in polypropylene syringes was studied. Twenty 1-mg vials of indomethacin sodium trihydrate were reconstituted with 2 mL of Sterile Water for Injection, USP. Solution from 10 vials was drawn into 20 1-mL disposable polypropylene syringes. Five vials and 10 syringes were stored at 21-25 degrees C, and the other 5 vials and 10 syringes were stored at 2-6 degrees C. Samples were taken on days 0, 1, 2, 4, 5, 7, 9, 12, and 14 and analyzed by liquid chromatography. Physical inspections and pH determinations were made as well. Throughout the study period, all solutions stored at 2-6 degrees C retained more than 95% of the initial indomethacin concentration. At room temperature, solutions stored in syringes retained more than 95% of the initial indomethacin concentration. Solutions stored in glass vials contained only 89.7% of the initial concentration on day 14. Solutions stored at room temperature in either syringes or vials had greater amounts of degradation products than solutions stored at 2-6 degrees C. Reconstituted indomethacin sodium trihydrate 0.5 mg/mL was stable for 14 days when stored in polypropylene syringes at 2-6 or 21-25 degrees C and in its original glass vials at 2-6 degrees C. When stored in the glass vials at 21-25 degrees C, the reconstituted drug was stable for 12 days.

Anti-Inflammatory Agents, Non-Steroidal↗

Changes in HIV risk behaviour in clients of syringe-exchange schemes in England and Scotland.

The impact of syringe-exchange schemes on the behaviour of injecting drug users was investigated through self-reported behaviour change. Fifteen syringe-exchange schemes in England and Scotland participated in a government-sponsored pilot programme from April 1987. Clients were provided with sterile injecting equipment and condoms, and with knowledge of HIV risks. One hundred and forty-two injecting drug users who first attended between April 1987 and March 1988 participated in a prospective interview-based survey with questions at two points in time. Measurements were self-reported attitudinal, knowledge and behavioural changes relevant to HIV infection and transmission. Many clients maintained or adopted low-risk behaviours: 79% sustained or adopted low or lower levels of syringe sharing. Trends identified include decreases in syringe-sharing, from 34 to 27%; using others' syringes (risk of infection) from 25 to 19%; passing on syringes (risk of transmission) from 30 to 25%. Many clients reported changes in sexual behaviour; those with sexual partners decreased from 77 to 69% and those with two or more sexual partners from 26 to 21%. However, non-use of condoms increased from 62 to 79%. Comparison groups of non-attenders showed higher levels of risk behaviour (59-62% sharing syringes, 86-88% with sexual partners). Overall, changes in HIV risk behaviour show small but encouraging trends and support arguments that injectors can be helped to change their behaviour, which could be of cumulative importance in reducing the spread of HIV.

Acquired Immunodeficiency Syndrome↗

Use of an illegal syringe exchange and injection-related risk behaviors among street-recruited injection drug users in Oakland, California, 1992 to 1995.

OBJECTIVE: To determine factors associated with syringe and injection supply sharing among injection drug users (IDUs) in a community with an illegal underground syringe exchange program (SEP). METHODS: From 1992 to 1995, semiannual cross-sectional samples of IDUs were recruited in Oakland, California. To account for multiple observations from the same individual, we used general estimating equations with logit transformations to determine factors associated with sharing syringes and other injection supplies. RESULTS: 1304 IDUs were interviewed; 684 (53%) returned for more than one interview. 2830 interviews were available for analysis. SEP use increased and syringe and supply sharing declined from 1992 to 1995 among study participants. In multivariate analysis, SEP users were less likely to share syringes than non-SEP users (adjusted odds ratio [AOR] = 0.57; 95% confidence interval [CI] = 0.46-0.72). SEP use was not significantly associated with the sharing of injection supplies (AOR = 0.85; 95% CI = 0.68-1.07). Syringe sharing and injection supply sharing were significantly less likely to occur among African American and HIV-positive IDUs. CONCLUSIONS: These data suggest that illegal SEPs can be effective HIV prevention programs. Lower rates of syringe-based risk behaviors among African American and HIV-positive IDUs are encouraging.

California↗

Preparation of 99mTc-Nanocoll for use in sentinel node localization: Validation of a protocol for supplying in unit-dose syringes.

OBJECTIVES: To determine if 99mTc-Nanocoll is affected by storage in a syringe, passage through an R-Lock or mixing with Patent Blue V dye. METHODS: A Nanocoll kit was reconstituted at 280 MBq/5 ml. Samples of 0.5 ml were drawn into 3 ml Plastipak syringes. After 1 h and 6 h, adsorption of 99mTc on a syringe was measured and the following tests of quality were performed on samples from the kit and a syringe: 99mTc-pertechnetate impurity by thin-layer chromatography, the percentage of 99mTc on particles >100 nm by Nuclepore filtration and particle size by photon correlation spectroscopy. These tests were also applied to samples that had been passed through an R-Lock or mixed with Patent Blue V. Each experiment was performed five times. RESULTS: In all samples, adsorption of 99mTc on syringes was <1%, 99mTc-pertechnetate impurity was <2%, >95% of 99mTc was labelled to particles <100 nm in diameter, the mean particle diameter was 6.6 nm and the particles had a diameter of <12 nm. All tests showed no significant difference (P > 0.05, n = 5) between 99mTc-Nanocoll from the original kit and a syringe at either 1 h or 6 h. Similar results were obtained with samples that had been passed through an R-Lock or mixed with Patent Blue V. CONCLUSIONS: A capped 3 ml Plastipak syringe is a suitable container in which to supply 99mTc-Nanocoll. Neither passage through an R-Lock nor mixing with Patent Blue V affects the quality of 99mTc-Nanocoll.

Drug Packaging↗

Disposable syringes for insulin injection.

Results of a questionnaire on use of glass syringes among diabetic patients showed considerable variation in methods of keeping the syringes and in the duration of their useful life. Thirty patients took part in an investigation in which each patient used the same disposable syringe in place of the glass syringe for up to two months. No clinical or bacteriological evidence of infection was found. Used in this way, disposable syringes were less expensive than glass syringes. They are lighter than glass syringes, less susceptible to damage, and more easily carried on journeys.

Costs and Cost Analysis↗

[Factors associated with sharing syringes among street-recruited injecting drug users].

BACKGROUND AND OBJECTIVE: To estimate the prevalence of risk behaviors related to drug use and to identify factors associated with of accepting and passing on used syringes among intravenous drug users (IDU) recruited in Barcelona city and other surrounding areas in 2004. SUBJECTS AND METHOD: A cross-sectional study of IDU recruited from the streets by ex-IDU interviewers. A standardized and anonymous questionnaire which explored behaviors in the previous 6 months was used. Saliva samples were collected to determine human immunodeficiency virus (HIV) prevalence. Logistic regression models were used to identify determinants of accepting and passing on used syringes. RESULTS: Of the 300 participants, 17.7% and 13.3% accepted and passed on used syringes, respectively. 74.8% practiced front-backloading (to prepare the drug solution in a syringe and then divide it up into other syringes) and 77.9% shared other equipment. The prevalence of HIV was 57.7%. The predictors of accepting used syringes were using more than 4 drugs (odds ratio [OR] = 5.6), having a positive hepatitis C virus status (OR = 7.3), practising front/backloading (OR = 12.6) and having an IDU steady partner (OR = 2.9); and with passing on used syringes were practicing front/backloading (OR = 4.9), having an IDU steady partner (OR = 5.8), and having sexual risk behaviors with casual partners (OR = 4.0). Starting to inject drugs older than 15 years of age was a protective factor (OR = 0.2). CONCLUSIONS: The prevalence of risk behaviors related to drug use remains high, especially indirect sharing, just as the prevalence of HIV and hepatitis C virus. Prevention programs should be targeted to IDU, especially to young IDU, polydrug users and those who have an IDU steady partner.

Adult↗

Consequences of syringe size sensor malfunction in a modern infusion pump.

Prompted by an actual case of potentially life-threatening infusion pump malfunction, we investigated the effects of wire breakage(s) within the syringe size sensor circuit in a Graseby 3400 infusion pump. The circuit wires within the sensor were systematically broken. The syringe sizes recognised by the sabotaged circuit and the actual sizes of syringes inserted into the pump were compared. Thirty-eight per cent of the possible wire breakages resulted in a smaller syringe size being recognized, causing the infusion rate to be too fast, and 38% of the possiblewire breakage resulted in a larger syringe size being recognized, causing the infusion rate to be too slow. The volume delivered for each different size of Terumo syringe as a function of distance travelled by the plunger was measured. The errors ranged from 0.4 to 2.6 times that of the expected rate. Only 1.3% of the possible wire breakage(s) were recognised as errors by the pump. The infusion rates were not affected in 22.5% of the cases. Wire breakage within the syringe size sensor in infusion pumps is yet another potential source of infusion error, with important safety implications.

Equipment Failure↗

Drugs and syringe drivers: a survey of adult specialist palliative care practice in the United Kingdom and Eire.

Subcutaneous delivery of drugs using a syringe driver is common practice within specialist palliative care units. There is, however, little documented information regarding clinical practice. A survey performed in 1992 reported that at least 28 drugs were used in combination with others in a single syringe driver. The aim of the present study was to reassess practice in this field and to enquire more specifically about newer drugs. Postal questionnaires were sent to all adult specialist palliative care in-patient units in the UK and Eire (n = 208). One hundred and sixty-five units (79%) responded. The most common syringe driver in use was the Graseby 26 (61% of responding units). Most units delivered the contents of the syringe over 24 h, and water was usually used as the diluent in 90% of cases. The maximum number of drugs that respondents were prepared to mix in a single syringe was usually three (51%) or four (35%). In the UK, all units used diamorphine in doses from 2.5 mg/24 h upwards. All respondents also used haloperidol, in doses from 0.5 to 60 mg/24 h. A total of 28 different drugs were used in syringe drivers. The most common combinations were diamorphine and midazolam (37%), diamorphine and levomepromazine (35%), diamorphine and haloperidol (33%), and diamorphine and cyclizine (31%). In conclusion, there is much in common with regard to the way in which drugs are delivered in syringe drivers. However, a wide variety of drugs and drug combinations are still in use.

Adult↗