Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “MASKS”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12Linked to original sources

Color-luminance interaction: data produced by oblique cross masking.

Threshold-elevation (TE-) versus-mask-spatial-frequency (SF) curves and TE-versus-mask-contrast curves, produced by the oblique-masking technique, were reported for uncrossed stimuli (color-test-on-color-mask and luminance-test-on-luminance-mask) [Invest. Ophthalmol. Visual Sci. Suppl. 34, 751 (1993) and Vision. Res. 23, 873 (1983)]. The technique minimizes the artifacts that are due to spatial phase effects, spatial beats, spatial probability summation, and local cues. My goal was to measure these curves for crossed stimuli (color-test-on-luminance-mask and luminance-test-on-color-mask) by this oblique-masking technique and to compare the curves with those reported in previous studies. For this purpose threshold contrasts were measured by a yes-no procedure with randomized double staircases. Test targets were vertical spatially localized (D6) patterns, and masks were oblique sinusoidal patterns; both the test and the mask were presented simultaneously, for 2 s (Gaussian window), on a color monitor interfaced with an ATVista system and a Powell achromatizing lens. The test SF's were 0.125, 0.5, 2, 4, and 8 cycles per degree (cpd); mask SF's were 0.031-16 cpd; and mask contrasts were 6.25%-50%. Furthermore, the Red-Green channel was defined by the minimum flicker and the hue cancellation techniques. Results show mostly masking effect (TE > 1) at contrasts above threshold; sometimes, separability (TE = 1) and above-threshold facilitation (TE < 1) effects were also observed, depending on the test SF, the mask SF, the mask contrast, and the subject. In general, the magnitudes of TE's are smaller and the TE-versus-mask-SF curves are slightly narrower for the oblique-cross-masking conditions than those for the respective oblique uncross masking. In addition, the TE-versus-mask-contrast curves for the crossed conditions are mostly shallower than those for the respective uncrossed conditions. Furthermore, mostly the color-luminance asymmetry (color masks luminance more than luminance masks color) is found, in mild form, for SF's > or = 0.5 cpd. For the lower SF of 0.125 cpd, there is either a lack of asymmetry or a very mild asymmetry of the opposite kind (luminance masks color slightly more than color masks luminance) seems to prevail. In general, the oblique-masking data shows mild asymmetry and reduced facilitation; both are consistent with reduced local cues, similar to those shown by randomized phase data, thus making the data suitable for SF analysis; moreover, at high contrast, the masking data are consistent with those reported in previous studies.

Adult↗

Dynamic contrast perception assessed by pattern masking.

The perceived contrast of a pulsed grating varies markedly with the exposure duration and spatial frequency of the grating. We studied dynamic changes in perceived grating contrast with a pattern-masking paradigm. We measured masking of a brief, localized test pattern (a D6 stimulus, 30 ms in duration) by fixed-contrast cosine grating patterns of varying duration (50-500 ms). The cosine mask pattern had spatial frequency of either 1 or 6 cycles per degree (cpd) at a contrast of 0.3. The D6 test pattern was centered on a light bar of the mask and was either positive peak contrast (same-polarity test and mask) or negative peak contrast (opposite-polarity test and mask). In Experiment 1, the test and mask had simultaneous onset. With a 6-cpd mask, the same-polarity test-threshold elevation versus mask-duration function increases monotonically. For a 1-cpd mask, the same-polarity threshold-mask-duration function is nonmonotonic, with peak masking effect produced by a grating pulse of 80-100 ms. These masking effects are closely congruent with known dynamic contrast effects. With negative tests, masking-duration functions are elevated from same-polarity functions and are essentially similar in shape for 1- and 6-cpd masks. The elevated thresholds suggest inhibitory interaction between ON and OFF pathways, with a similar time course across spatial frequency. In Experiment 2, the D6 test was delayed from mask onset by 33 ms. Positive contrasts only were employed. For 1-cpd stimuli, the delay of test greatly reduced masking at all mask durations and eliminated the nonmonotonic function. This suggests that for low-spatial-frequency patterns, perceived contrast is determined by an early peak component of the neural response. But for 6-cpd stimuli, masking of the delayed test was somewhat greater at all mask durations, consistent with a gradually increasing underlying neural response to the grating. Finally, in Experiment 3, same-polarity masking effects at both spatial frequencies were replicated with negative-contrast test and mask (OFF pathway mediation). This indicates that the ON and OFF pathways have similar response dynamics.

Contrast Sensitivity↗

Backward-masking: the effect of the duration of the second stimulus on recognition of the first stimulus.

OBJECTIVE: We recorded event-related magnetic fields following a target stimulus followed by a masking stimulus to investigate the visual backward masking effect using a helmet-type magnetoencephalography system in humans. METHODS: In the target stimulus with masking stimulus conditions, duration of the target stimulus was constant at 16 ms, and duration of the masking stimulus was altered (16, 48 and 144 ms). The target stimulus was masked by the 144-ms masking stimulus, but not by the 16-ms masking stimulus, and was obscured by the 48-ms masking stimulus. For control conditions (Single-condition), event-related magnetic fields were recorded following the sole presentation of the masking stimulus for 32, 64 or 160 ms. RESULTS: One major response was obtained at 180 ms after the onset of the stimulation in each condition. The equivalent current dipole of one major response was estimated to lie in the occipital lobe, but there was a relatively large inter-individual difference. There was no significant difference in latency between the target stimulus with masking stimulus conditions and Single-conditions. In the target stimulus with masking stimulus conditions with the 48- and 144-ms masking stimulus, the root mean square value did not differ from that in the respective Single-condition, while the root mean square value for the target stimulus with masking stimulus conditions with the 16-ms masking stimulus was significantly smaller than that in the Single-condition with the 32-ms masking stimulus, but not different from that in the Single-condition with the 16-ms masking stimulus. CONCLUSIONS: The peak latency of one major response depended on the onset of the first stimulus for both the target stimulus with masking stimulus conditions and Single-condition, but the root mean square value depended on the duration of the masking stimulus. We concluded that the temporal information for the target stimulus was preserved during the masking effect, while the figural information was interrupted by the masking stimulus. Our results suggested that temporal factors for the stimulus were processed differently from those responsible for the object's recognition during backward masking.

Brain↗

Comparison of plastic and Orfit masks for patient head fixation during radiotherapy: precision and costs.

PURPOSE: Two widely used immobilization systems for head fixation during radiotherapy treatment for ear-nose-throat (ENT) tumors are evaluated. METHODS AND MATERIALS: Masks made of poly vinyl-chloride (plastic) are compared to thermoplastic masks (Orfit) with respect to the accuracy of the treatment setup and the costs. For both types of material, a cut-out (windows corresponding to treatment fields) and a full mask (not cut out) are considered. Forty-three patients treated for ENT tumors were randomized into four groups, to be fixed by one of the following modalities: cut-out plastic mask (12 patients), full plastic mask (11 patients), cut-out Orfit mask (10 patients), and full Orfit mask (10 patients). RESULTS: Reproducibility of the treatment setup was assessed by calculating the deviations from the mean value for each individual patient and was demonstrated to be identical for all subgroups: no differences were demonstrated between the plastic (s = 2.1 mm) and the Orfit (s = 2.1 mm) group nor between the cut-out (s = 2.0 mm) and not cut-out (s = 2.1 mm) group. The transfer chain from similar to treatment unit was checked by comparing portal images to their respective simulation image, and no differences between the four subgroups (s = +/- 3.5 mm) could be detected. A methodology was described to compare the costs of both types of masks, and illustrated with the data for a department. It was found that Orfit masks are a cheaper alternative than plastic masks; they require much less investment expenses and the workload and material cost of the first mask for each patient is also lower. Cut-out masks are more expensive than full masks, because of the higher workload and the additional material required for second and third masks that are required in case of field modifications. CONCLUSIONS: No substantial difference in patient setup accuracy between both types of masks was detected, and cutting out the masks had no impact on the fixing capabilities. A first Orfit mask will typically be a cheaper alternative than a plastic mask for most departments (lower fixed and variable costs). The higher material cost of the subsequent Orfit masks, compared to the plastic masks, offset the lower investment expenses.

Costs and Cost Analysis↗

Technical validation of a face mask adapted for dry powder inhalation in the equine species.

Development of dry powder inhalation (DPI) for horses requires the use of an adapted face mask. In experiment I, 4 masks (A, B, C and D) were tested and factors influencing the delivery of the dry powder were determined. Mask A was one which is commercially available for metered-dose inhalation. Mask B had the same shape as Mask A but an airtight rubber seal was added for the connection between the mask and horse's head. Mask C was a prototype adapted for DPI with connection for the DPI device between the nostrils, airtight expiratory valves in front of each nostril and airtight rubber seal to attach the mask on the horse's head. Mask D was the same as Mask C but the airtight expiratory valve was situated in front of one nostril and the connection for the DPI device was placed in front of the other nostril. Inhalet emptying and peak inspiratory pressure were measured on 5 healthy horses with each face mask. Both Masks A and B gave a low rate of inhalet emptying. Inspiratory pressures created in Masks C and D were negative enough to ensure inhalet emptying rates of mean +/- s.d. 98.28 +/- 1.79% and 100% respectively. In experiment 2, the face masks giving the greatest inhalet emptying were used to test the therapeutic efficacy of ipratropium bromide DPI. This was tested on 6 horses suffering from acute exacerbation of chronic obstructive pulmonary disease (COPD). At a dose of 200 micrograms/100 kg bwt, ipratropium administered with Mask D improved significantly pulmonary function measurements compared to baseline values and placebo inhalation. With Mask C, a double dose of ipratropium (400 micrograms/100 kg bwt) was necessary to improve these parameters compared to baseline values. This indicated the importance of locating the DPI device in front of one nostril. It was concluded that inhalet emptying is correlated to inspiratory pressures measured in the face masks. Secondly, these pressures are in turn dependent on the air-tightness of the mask, i.e. air-tightness of the expiratory valve and close connection between the horse's head and the mask. Thirdly, position of the DPI device in front of a nostril allows bronchodilation at a dose half that required when the device is placed between the nostrils. Finally DPI using Mask D (EquiPoudre) is a rapid, effective and well tolerated inhalation treatment for COPD horses.

Administration, Inhalation↗

The efficacy of a custom-fabricated nasal mask on gas exchange during nasal intermittent positive pressure ventilation.

Commercially available nasal masks have a large mask volume and give rise to considerable air leaks around the mask during nasal intermittent positive pressure ventilation (NIPPV) which may reduce alveolar ventilation (VA per breath). The effects of a custom-fabricated nasal mask (F-mask) versus a commercially available mask (C-mask) on arterial blood gas measurements, dead space including both physiological and apparatus dead space (VD), air leak and VA per breath were compared in patients with restrictive thoracic disease during short-term NIPPV sessions while using a volume cycled ventilator with equivalent settings for both masks. The mask volume of the C-mask was significantly larger than that of the F-mask (p<0.003). The arterial carbon dioxide tension (Pa,CO2) during NIPPV with either the F-mask (5.56+/-1.35 kPa) (mean+/-SD) or the C-mask (6.87+/-0.96 kPa) was significantly lower than during spontaneous breathing (7.75+/-0.81 kPa; p<0.003), but the Pa,CO2 decreased more during NIPPV with the F-mask than with the C-mask (p<0.003). The VD was significantly smaller (p<0.03), the air leak was significantly less (p<0.03), and the VA per breath was significantly larger (p<0.03) during NIPPV with the F-mask than with the C-mask. In conclusion, nasal intermittent positive pressure ventilation with the F-mask was more effective than nasal intermittent positive pressure ventilation with the commercially available mask due to its smaller dead space and less air leak. Further studies are needed to extend these results to all the commercially available-masks.

Blood Gas Analysis↗

Mask mechanics and leak dynamics during noninvasive pressure support ventilation: a bench study.

OBJECTIVE: To study the mask mechanics and air leak dynamics during noninvasive pressure support ventilation. SETTING: Laboratory of a university hospital. DESIGN: A facial mask was connected to a mannequin head that was part of a mechanical respiratory system model. The mask fit pressure (P(mask-fit)) measured inside the mask's pneumatic cushion was adjusted to 25 cmH(2)O using elastic straps. Pressure support (PS) was set to ensure a maximal tidal volume distal to the mask (VT(distal)) but avoiding failure to cycle to exhalation. MEASUREMENTS: Airway pressure (P(aw)), P(mask-fit), mask occlusion pressure (P(mask-occl)=P(mask-fit)-P(aw)), VT proximal (VT(prox)), distal to the mask (VT(distal)), air leak volume ( Leak=VT(prox)-VT(distal)), and inspiratory air leak flow rate (difference between inspiratory flow proximal and distal to the mask) were recorded. RESULTS: PS 15 cmH(2)O was the highest level that could be used without failure to cycle to exhalation (VT(distal) of 585+/-4 ml, leak of 32+/-1 ml or 5.2+/-0.2% of VT(prox), and a minimum P(mask-occl) of 1.7+/-0.1 cmH(2)O). During PS 16 cmH(2)O the P(mask-occl) dropped to 1.1+/-0.1 cmH(2)O, and at this point all flow delivered by the ventilator leaked around the mask, preventing the inspiratory flow delivered by the ventilator from reaching the expiratory trigger threshold. CONCLUSION: P(mask-fit) and P(mask-occl) can be easily measured in pneumatic cushioned masks and the data obtained may be useful to guide mask fit and inspiratory pressure set during noninvasive positive pressure ventilation.

Equipment Failure Analysis↗

Visual processing in schizophrenia: Structural equation modeling of visual masking performance.

Schizophrenic patients consistently demonstrate performance deficits on visual masking procedures. In visual masking, the subject's ability to process a target stimulus is reduced by another stimulus (mask) presented either before (forward masking) or after (backward masking) the target. Masking procedures employed in schizophrenia research have used several experimental paradigms. Most early studies have used high-energy masks (i.e., the mask is stronger than the target) and spatially overlapping target and mask. More recently, studies have begun to employ relatively weak (i.e., low-energy) masks, as well as masks that surround, but do not spatially overlap, the target. Data for forward and backward masking components of four masking conditions (target location and identification with a high-energy mask, target identification with a low-energy mask, and target identification with equal energy paracontrast/metacontrast) were collected from 75 patients with schizophrenia. Based on theoretical distinctions among masking procedures, we compared four models of visual masking using structural equation modeling. Although high zero-order correlations were found among the masking parameters, a four-factor model, in which factors were separated on the type of response (target location and identification), the shape of the function (monotonic and non-monotonic), and the overlap of the stimuli (overlapping and non-overlapping), provided the best fit for the data. These findings suggest that the four masking procedures used in this study may tap unique aspects of visual processing and are not redundant. The results also support theories of the different mechanisms underlying performance on these measures.

Adult↗

Force-dependent static dead space of face masks used with holding chambers.

BACKGROUND: Pressurized metered-dose inhalers with valved holding chambers and masks are commonly used for aerosol delivery in children. Drug delivery can decrease when the dead-space volume (DSV) of the valved holding chamber is increased, but there are no published data evaluating force-dependent DSV among different masks. METHODS: Seven masks were studied. Masks were sealed at the valved holding chamber end and filled with water to measure mask volume. To measure mask DSV we used a mannequin of 2-year-old-size face and we applied the mask with forces of 1.5, 3.5, and 7 pounds. Mask seal was determined by direct observation. Intra-brand analysis was done via analysis of variance. RESULTS: At 3.5 pounds of force, the DSV ranged from 29 mL to 100 mL, with 3 masks having DSV of < 50 mL. The remaining masks all had DSV > 60 mL. At 3.5 pounds of force, DSV percent of mask volume ranged from 33.7% (Aerochamber, p < 0.01 compared with other masks) to 100% (Pocket Chamber). DSV decreased with increasing force with most of the masks, and the slope of this line was inversely proportional to mask flexibility. Mask fit was 100% at 1.5 pounds of force only with the Aerochamber and Optichamber. Mask fit was poorest with the Vortex, Pocket Chamber, and BreatheRite masks. CONCLUSION: Rigid masks with large DSV might not be not suitable for use in children, especially if discomfort from the stiff mask makes its use less acceptable to the child.

Administration, Inhalation↗

Modified N95 mask delivers high inspired oxygen concentrations while effectively filtering aerosolized microparticles.

STUDY OBJECTIVE: In a pandemic, hypoxic patients will require an effective oxygen (O2) delivery mask that protects them from inhaling aerosolized particles produced by others, as well as protecting the health care provider from exposure from the patient. We modified an existing N95 mask to optimize O2 supplementation while maintaining respiratory isolation. METHODS: An N95 mask was modified to deliver O2 by inserting a plastic manifold consisting of a 1-way inspiratory valve, an O2 inlet and a gas reservoir. In a prospective repeated-measures study, we studied 10 healthy volunteers in each of 3 phases, investigating (1) the fractional inspiratory concentrations of O2 (F(I)O2) delivered by the N95 O2 mask, the Hi-Ox80 O2 mask, and the nonrebreathing mask during resting ventilation and hyperventilation, each at 3 O2 flow rates; (2) the ability of the N95 mask, the N95 O2 mask, and the nonrebreathing mask to filter microparticles from ambient air; and (3) to contain microparticles generated inside the mask. RESULTS: The F(I)O2s (median [range]) delivered by the Hi-Ox80 O2 mask, the N95 O2 mask, and the nonrebreathing mask during resting ventilation, at 8 L/minute O2 flow, were 0.90 (0.79 to 0.96), 0.68 (0.60 to 0.85), and 0.59 (0.52 to 0.68), respectively. During hyperventilation, the FiO2s of all 3 masks were clinically equivalent. The N95 O2 mask, but not the nonrebreathing mask, provided the same efficiency of filtration of internal and external particles as the original N95, regardless of O2 flow into the mask. CONCLUSION: An N95 mask can be modified to administer a clinically equivalent FiO2 to a nonrebreathing mask while maintaining its filtration and isolation capabilities.

Aerosols↗

Forward and backward visual masking in schizophrenia: influence of age.

BACKGROUND: Visual masking tasks assess the earliest stages of visual processing. This study was conducted to address: (1) whether schizophrenia patients show masking deficits after controlling for sensory input factors; (2) whether patients have relatively intact forward masking (when the mask precedes the target) compared with backward masking (when the mask follows the target); and (3) whether the masking deficits in schizophrenia reflect an accelerated age-related decline in performance. METHOD: A staircase method was used to ensure that the unmasked target identification was equivalent across subjects to eliminate any confounding due to differences in discrimination of simple perceptual inputs. Three computerized visual masking tasks were administered to 120 schizophrenia patients (ages 18-56) and 55 normal comparison subjects (ages 19-54) under both forward and backward masking conditions. The tasks included: (1) locating a target; (2) identifying a target with a high-energy mask; and (3) identifying a target with a low-energy mask. RESULTS: Patients showed deficits across all three masking tasks. Interactions of group by forward versus backward masking were not significant, suggesting that deficits in forward and backward masking were comparable. All three conditions showed an age-related decline in performance and rates of decline were comparable between patients and controls. Two of the masking conditions showed increased rates of decline in backward, compared to forward, masking. CONCLUSIONS: We found age-related decline in performance that was comparable for the two groups. In addition, we failed to find evidence of a relative sparing of forward masking in schizophrenia. These results suggest that: (1) early visual processing deficits in schizophrenia are not due to a simple perceptual input problem; (2) sustained channels are involved in the masking deficit (in addition to transient channels); and (3) for the age range in this study, these deficits in schizophrenia are not age-related.

Adolescent↗

Linearized response growth inferred from growth-of-masking slopes in ears with cochlear hearing loss.

Growth of masking for OFF-frequency conditions (probe frequency above the masker spectrum) and ON-frequency conditions (probe within the masker spectrum) was investigated using simultaneous masking in three subjects with normal hearing and nine subjects with high-frequency sensorineural hearing loss. Growth-of-masking functions (probe thresholds as a function of masker intensity) for OFF-frequency conditions were obtained for probe tones placed at six frequencies above a 200-Hz-wide masker with an upper edge at 520 Hz. Growth-of-masking functions for ON-frequency conditions were obtained for probe tones placed within the 200-Hz-wide masker and for probe tones placed within 400-Hz-wide maskers with upper edges at 1040, 1300, 1627, and 2040 Hz (probe tones placed 20 Hz below the upper edge frequency). Growth-of-masking functions were fit with a power function of masker intensity added to an internal noise with intensity equal to the absolute threshold for the probe, and were well described by two free parameters and a threshold constant: the growth-of-masking slope (beta), a masking sensitivity constant (kappa) that indicated the minimum effective masker level at which masking began, and the intensity of the probe at absolute threshold (IT). For OFF-frequency masking conditions, growth-of-masking slopes (beta) decreased by a factor of 0.8 for every 10 dB of hearing loss. Comparisons with data from previous studies of upward spread of masking, and assumptions about underlying physiological mechanisms, led to the conclusion that more gradual than normal growth-of-masking slopes reflect larger (steeper) growth-of-response slopes at the probe frequency in regions of hearing loss. Derived response-growth exponents increased by a factor of 1.2 for every 10 dB of hearing loss (HL), from an exponent around 0.25 at 0 dB HL to an exponent around 1.0 at 75 dB HL (linear response growth). Masking sensitivity constants (kappa), the minimum effective masker levels, indicated that masking began at slightly higher masker levels in subjects with sensorineural hearing loss than in subjects with normal hearing. It was concluded that higher masked thresholds in regions of hearing loss were due primarily to a loss of active gain at the probe frequency and were not due to an excessive response at the probe frequency to the lower-frequency masker. For ON-frequency masking conditions, growth-of-masking slopes were not different from normal in hearing-impaired subjects. ON-frequency masking began when the effective power within an auditory filter at the probe frequency reached elevated absolute threshold at the probe frequency. Critical ratios were normal except for one subject with the most hearing loss.

Adult↗

Neonatal resuscitation 2: an evaluation of manual ventilation devices and face masks.

BACKGROUND: The key to successful neonatal resuscitation is effective ventilation. Little evidence exists to guide clinicians in their choice of manual ventilation device or face mask. The expiratory tidal volume measured at the mask (V(TE(mask))) is a good estimate of the tidal volume delivered during simulated neonatal resuscitation. AIM: To compare the efficacy of (a) the Laerdal infant resuscitator and the Neopuff infant resuscitator, used with (b) round and anatomically shaped masks in a model of neonatal resuscitation. METHODS: Thirty four participants gave positive pressure ventilation to a mannequin at specified pressures with each of the four device-mask combinations. Flow, inspiratory tidal volume at the face mask (V(TI(mask))), V(TE(mask)), and airway pressure were recorded. Leakage from the mask was calculated from V(TI(mask)) and V(TE(mask)). RESULTS: A total of 10,780 inflations were recorded and analysed. Peak inspiratory pressure targets were achieved equally with the Laerdal and Neopuff resuscitators. Positive end expiratory pressure was delivered with the Neopuff but not the Laerdal device. Despite similar peak pressures, V(TE(mask)) varied widely. Mask leakage was large for each combination of device and mask. There were no differences between the masks. CONCLUSION: During face mask ventilation of a neonatal resuscitation mannequin, there are large leaks around the face mask. Airway pressure is a poor proxy for volume delivered during positive pressure ventilation through a mask.

Air Pressure↗

Backward masking in schizophrenia and mania. I. Specifying a mechanism.

BACKGROUND: Backward masking is a neuropsychological procedure that involves the earliest phases of visual processing. Compared with normal controls, the performance of schizophrenic patients is more disrupted by a visual mask. Masking procedures used previously with schizophrenic patients have combined two separate masking mechanisms (interruption and integration), which prevent interpretation of the nature of the abnormality. The current study systematically limited the masking mechanism to interruption to specify the underlying mechanisms. Manic patients were included to examine diagnostic specificity. METHODS: Sixty-three schizophrenic inpatients, 31 manic inpatients, and 48 normal controls received three versions of the backward masking procedure. One version used a high-energy mask that combines both integration and interruption mechanisms. Another procedure used a low-energy mask that works mainly through interruption. A final condition altered the features of the mask so that masking was almost entirely through interruption. RESULTS: Schizophrenic patients showed performance deficits across masking conditions, even in procedures that were largely limited to masking by interruption. The masking performance of the patients did not appear to fit a simple generalized deficit. Manic patients performed significantly worse than normal controls and comparably with the schizophrenic patients. CONCLUSIONS: Schizophrenic patients have abnormalities at least with interruptive mechanisms. The results suggest that deficits on masking procedures are not entirely specific to schizophrenia because comparable masking deficits were found in manic inpatients with chronic disease. The current study addresses the neuropsychological mechanisms of the masking deficit. The next step will be to investigate the contributions of two distinct neuroanatomical visual pathways to the masking abnormality in schizophrenia.

Adult↗

Crowding is unlike ordinary masking: distinguishing feature integration from detection.

A letter in the peripheral visual field is much harder to identify in the presence of nearby letters. This is "crowding." Both crowding and ordinary masking are special cases of "masking," which, in general, refers to any effect of a "mask" pattern on the discriminability of a signal. Here we characterize crowding, and propose a diagnostic test to distinguish it from ordinary masking. In ordinary masking, the signal disappears. In crowding, it remains visible, but is ambiguous, jumbled with its neighbors. Masks are usually effective only if they overlap the signal, but the crowding effect extends over a large region. The width of that region is proportional to signal eccentricity from the fovea and independent of signal size, mask size, mask contrast, signal and mask font, and number of masks. At 4 deg eccentricity, the threshold contrast for identification of a 0.32 deg signal letter is elevated (up to six-fold) by mask letters anywhere in a 2.3 deg region, 7 times wider than the signal. In ordinary masking, threshold contrast rises as a power function of mask contrast, with a shallow log-log slope of 0.5 to 1, whereas, in crowding, threshold is a sigmoidal function of mask contrast, with a steep log-log slope of 2 at close spacing. Most remarkably, although the threshold elevation decreases exponentially with spacing, the threshold and saturation contrasts of crowding are independent of spacing. Finally, ordinary masking is similar for detection and identification, but crowding occurs only for identification, not detection. More precisely, crowding occurs only in tasks that cannot be done based on a single detection by coarsely coded feature detectors. These results (and observers' introspections) suggest that ordinary masking blocks feature detection, so the signal disappears, while crowding (like "illusory conjunction") is excessive feature integration - detected features are integrated over an inappropriately large area because there are no smaller integration fields - so the integrated signal is ambiguous, jumbled with the mask. In illusory conjunction, observers see an object that is not there made up of features that are. A survey of the illusory conjunction literature finds that most of the illusory conjunction results are consistent with the spatial crowding described here, which depends on spatial proximity, independent of time pressure. The rest seem to arise through a distinct phenomenon that one might call "temporal crowding," which depends on time pressure ("overloading attention"), independent of spatial proximity.

Contrast Sensitivity↗