Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Liquid Phase Microextraction”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12Linked to original sources

Recent developments in the analysis of brominated flame retardants and brominated natural compounds.

This article reviews recent literature on the analysis of brominated flame retardants (BFRs) and brominated natural compounds (BNCs). The main literature sources are reviews from the last five years and research articles reporting new analytical developments published between 2003 and 2006. Sample pretreatment, extraction, clean-up and fractionation, injection techniques, chromatographic separation, detection methods, quality control and method validation are discussed. Only few new techniques, such as solid-phase microextraction (SPME) or pressurized liquid extraction (PLE), have been investigated for their ability of combining the extraction and clean-up steps. With respect to the separation of BFRs, the most important developments were the use of comprehensive two-dimensional gas chromatography for polybrominated diphenyl ethers (PBDEs) and the growing tendency for liquid-chromatographic techniques for hexabromocyclododecane (HBCD) stereoisomers and of tetrabromobisphenol-A (TBBP-A). At the detection stage, mass spectrometry (MS) has been developed as well-established and reliable technology in the identification and quantification of BFRs. A growing attention has been paid to quality assurance. Interlaboratory exercises directed towards BFRs have grown in popularity and have enabled laboratories to validate analytical methods and to guarantee the quality of their results. The analytical procedures used for the identification and characterization of several classes of BNCs, such as methoxylated polybrominated diphenyl ethers (MeO-PBDEs) (also metabolites of PBDEs), halogenated methyl or dimethyl bipyrroles (DBPs), are reviewed here for the first time. These compounds were generally identified during the routine analysis of BFRs and have received little attention until recently. For each topic, an overview is presented of its current status.

Analytic Sample Preparation Methods↗

Mycoactive acetate esters from apple fruit stimulate adhesion and germination of conidia of the gray mold fungus.

Ethyl acetate, 2-methylbutyl acetate, butyl acetate (BA), and hexyl acetate were detected by solid-phase microextraction and gas-liquid chromatography inside slices of Golden Delicious apple and in water droplets on the skin of slices incubated in sealed glass jars. Conidial adhesion and germination of the gray mold fungus, Botrytis cinerea, was assessed on apple slices after exposure or no exposure to the esters in the headspaces of glass jars. Attached conidia were dislodged by sonication and remaining conidia on apple slices were counted by microscopy. Adhesion generally increased as BA increased to 7.2 microg mL(-1), but declined with greater concentrations. BA at 0-3.6 microg mL(-1) for 24 h stimulated adhesion 2-fold greater compared to that at 4 h. Adhesion stimulated by BA increased as a function of time (0-24 h), showing linear trends (r (2) = 0.99; p = 0.01) during 0-12 h. The four esters were similar in their ability to stimulate adhesion. Germination of conidia exposed to BA increased linearly (r (2) = 0.95-0.98; p = 0.01) during 4-12 h. Conidial adhesion stimulated by BA preceded conidial germination by 2 h. The four esters stimulated conidial germination to similar levels. Results indicated that acetate esters formed in apple fruit are mycoactive, influencing life-cycle events of B. cinerea important to its survival on the fruit. The similar responses of three B. cinerea isolates to four acetate esters suggests a common stimulation mechanism may operate in B. cinerea.

Acetates↗

Determination of 3-chloropropane-1,2-diol in liquid hydrolyzed vegetable proteins and soy sauce by solid-phase microextraction and gas chromatography/mass spectrometry.

Headspace solid-phase microextraction (HS-SPME) coupled with gas chromatography/mass spectrometry (GC/MS) method was developed to determine 3-chloropropane-1,2-diol (3-MCPD) in hydrolyzed vegetable protein and Chinese soy sauce. The 3-MCPD was firstly derivativized with phenylboronic acid in aqueous solution at 90 degrees C for 10 min, then extracted by HS-SPME and finally detected with GC/MS, parameters related to both the derivative reaction and the HS-SPME process were optimized. The proposed method has a linear range of 0.0194-394 microg g(-1), a detection limit of 3.87 ng g(-1) (S/N = 3), and a precision of RSD = 7.5% (n = 5). Seventeen real samples, including four HVPs and thirteen soy sauce samples, were analyzed to examine the feasibility of the proposed procedure; with a concentration of 3-MCPD and acceptable recoveries at 0.71 microg g(-1) spiked levels were obtained. Being simpler, faster and more environmentally benign than the existing methods, this method is accurate and suitable for routine analysis.

Boronic Acids↗

Simple and rapid analysis of endocrine disruptors in liquid medicines and intravenous injection solutions by automated in-tube solid-phase microextraction/high performance liquid chromatography.

A simple and rapid method was developed for analyzing contamination of endocrine disruptors in liquid medicines and intravenous injection solutions. Endocrine disrupting compounds such as bisphenol A (BPA), alkylphenols and phthalates were quantitated by on-line in-tube solid-phase microextraction coupled with high performance liquid chromatography (in-tube SPME/HPLC) with UV detection. The liquid medicines and intravenous injection solutions could be used directly without any pretreatment, and the BPA, alkylphenols and phthalates in these solutions were automatically analyzed. The limits of quantification for these compounds were 1-10 ng/ml. Recoveries of these compounds spiked to the intravenous injection solutions was over 80%, except for some phthalates. Di-n-butyl phthalate (DBP) was detected at a concentration of 7-60 ng/ml in most intravenous injection solutions in plastic containers, but it was not detected in solutions in glass bottles. Diethyl phthalate, di-n-propyl phthalate, DBP and di-2-ethylhexyl phthalate (DEHP) were also detected in syrup, lotion and eye drops in plastic containers. On the other hand, BPA and alkylphenols were not detected at all in these solutions. DEHP contamination from an administration set increased when total vitamin formulation was added to the infusion solution. DEHP was easily leached from polyvinyl chloride tubing by polysorbate 80. The in-tube SPME/HPLC method is simple, rapid and automatic, and it provides a useful tool for the screening and determination of endocrine disruptor contamination in liquid medicines and intravenous injection solutions.

Autoanalysis↗

Use of solid-phase microextraction for measuring oil-water partition coefficients and correlation with high-performance liquid chromatographic methods for lipophilicity.

For flavour compounds, lipophilicity is often estimated by the partition coefficient between oil and water (log Koil-water), which is highly relevant to food. A modification of the shake-flask method is reported here where compounds are quantified in the two phases using solid-phase microextraction (SPME). SPME's highly sensitivity to non-polar compounds facilitates quantification in the water phase. Twelve flavour compounds representing a broad range of lipophilicities and functional groups were analysed by two methods. Their log Koil-water was determined using SPME quantitation and their log k(w) using a reversed-phase HPLC methodology. The isocratic capacity factor at 60% methanol and predicted log P value also showed high correlation factors with other methods. The octadecyl silylated surface of the HPLC column provides a matrix that interacts with lipophilic compounds where the retention time is the indication of lipophilicity. Both methods gave reproducible results (median 3% and 4% RSD) and similar but not identical values for lipophilicity. The relationship between the two methods is log k(w) =0.85 log Koil-water +0.48 with a correlation coefficient of 0.94. The new SPME detection method, with the ability to quantify limonene and 2-pentylfuran at 1 ppm in the water phase, is preferred for flavour compound analysis due to the applicability of oil-water partitioning in food.

Buffers↗

Evaluation of solid-phase microextraction as an alternative to the official method for the analysis of organic micro-pollutants in drinking water.

The objective this study was to compare the official EU liquid-liquid extraction (LLE) method with solid-phase microextraction (SPME) for the analysis of compounds migrating from cross-linked polyethylene into water. A medium polarity polydimethylsiloxane/divinylbenzene (PDMS/DVB) 65 microm fibre proved most efficient for the SPME extraction of nine test compounds and the optimum extraction conditions were an immersion time of 30 min with heating to 60 degrees C. The repeatability of the SPME method was variable: RSD values ranged from approximately 4-18% depending on the individual compound, though correlation coefficients were greater than 0.999 in the concentration range 0.5-1000 microg/l. It would also seem that there is some competition amongst different compounds for sites on the fibre and this is a potential drawback of SPME when applied to unknown samples. However, when applied to water samples in contact with polyethylene, SPME proved to be immensely more sensitive and to have a greater extraction range than LLE. These factors coupled with the rapidity and ease of use of SPME mean that it could be developed for use as an alternative to the existing official method or as an alert system in the routine analysis of materials used to transport domestic water.

Chemical Fractionation↗

An evaluation of solid phase microextraction for aliphatic amines using derivatization with 9-fluorenylmethyl chloroformate and liquid chromatography.

The reliability of SPME combined with a chemical reaction for the analysis of short-chain aliphatic amines by liquid chromatography has been investigated. Different options to couple SPME and derivatization have been tested and compared: (i) derivatization of the analytes in solution followed by the extraction of the derivatives, (ii) extraction of the analytes and subsequent derivatization by immersing the SPME fibre onto a solution of the reagent, and (iii) extraction/derivatization of the analytes using fibres previously coated with the reagent. Methylamine (MA), dimethylamine (DMA) and trimethylamine (TMA) have been selected as a model of primary, secondary and tertiary amines, respectively. The analytes have been derivatized with the fluorogenic reagent 9-fluorenylmethyl chloroformate (FMOC), and the fibre coating was Carbowax-templated resin (CW-TR). The employment of fibres coated with FMOC to extract and derivatize the analytes was the best option, as compared with the other approaches tested the sensitivity was considerably improved. On the basis of these studies, a new procedure for the determination of MA, DMA and TMA in water is presented. To demonstrate the utility of the proposed conditions data on linearity, accuracy, repeatability and sensitivity are given. Results of the determination of the amines in tap, river and waste water are also presented.

Amines↗

Measurement of gas-liquid partition coefficient and headspace concentration profiles of perfume materials by solid-phase microextraction and capillary gas chromatography-mass spectrometry

An empirical model describing the relationship between the partition coefficients (K) of perfume materials in the solid-phase microextraction (SPME) fiber stationary phase and the Linearly Temperature Programmed Retention Index (LTPRI) is obtained. This is established using a mixture of eleven selected fragrance materials spiked in mineral oil at different concentration levels to simulate liquid laundry detergent matrices. Headspace concentrations of the materials are measured using both static headspace and SPME-gas chromatography analysis. The empirical model is tested by measuring the K values for fourteen perfume materials experimentally. Three of the calculated K values are within 2-19% of the measured K value, and the other eleven calculated K values are within 22-59%. This range of deviation is understandable because a diverse mixture was used to cover most chemical functionalities in order to make the model generally applicable. Better prediction accuracy is expected when a model is established using a specific category of compounds, such as hydrocarbons or aromatics. The use of this method to estimate distribution constants of fragrance materials in liquid matrices is demonstrated. The headspace SPME using the established relationship between the gas-liquid partition coefficient and the LTPRI is applied to measure the headspace concentration of fragrances. It is demonstrated that this approach can be used to monitor the headspace perfume profiles over consumer laundry and cleaning products. This method can provide high sample throughput, reproducibility, simplicity, and accuracy for many applications for screening major fragrance materials over consumer products. The approach demonstrated here can be used to translate headspace SPME results into true static headspace concentration profiles. This translation is critical for obtaining the gas-phase composition by correcting for the inherent differential partitioning of analytes into the fiber stationary phase.

Journal Article↗

In-tube solid-phase microextraction with poly(methacrylic acid-ethylene glycol dimethacrylate) monolithic capillary for direct high-performance liquid chromatographic determination of ketamine in urine samples.

Ketamine was used for anaesthesia originally but has emerged as an abused drug in recent years. The prevalence of ketamine abuse demands a direct and rapid determination method. It is known that in-tube solid phase microextraction (in-tube SPME) can perform extraction with a capillary linked directly to a HPLC system, providing an automated and accurate extraction procedure. In this paper, an in-tube SPME coupled to HPLC method was developed for the determination of ketamine in urine samples with a poly(methacrylic acid-ethylene glycol dimethacrylate) monolithic capillary column as the extraction phase, which is expected to provide higher extraction efficiency than open tubular capillaries. After optimizing the extraction conditions, ketamine was extracted directly from urine samples in a wide dynamic linear range of 50-10,000 ng mL(-1), with the detection limit obtained as 6.4 ng mL(-1). The intra-day and inter-day precision for the method was 1.6% and 1.7%, respectively. The urine samples from suspect addicts have been successfully analyzed within 20 min. The re-usability of the monolithic column was also confirmed as no decrease of the extraction efficiency was shown after urine extraction.

Chromatography, High Pressure Liquid↗

A review of modern sample-preparation techniques for the extraction and analysis of medicinal plants.

Sample preparation is the crucial first step in the analysis of herbs. In recent years there has been increasing interest worldwide in the use of alternative/herbal medicine for the prevention and treatment of various illnesses. Currently, however, quality-related problems (lack of consistency, safety, and efficacy) seem to be overshadowing the potential genuine health benefits of various herbal products. Thus, the development of "modern" sample-preparation techniques with significant advantages over conventional methods for the extraction and analysis of medicinal plants is likely to play an important role in the overall effort of ensuring and providing high-quality herbal products to consumers worldwide. In this article, recent developments and applications of modern sample-preparation techniques for the extraction, clean-up, and concentration of analytes from medicinal plants or herbal materials are reviewed. These modern techniques include solid-phase microextraction, supercritical-fluid extraction, pressurized-liquid extraction, microwave-assisted extraction, solid-phase extraction, and surfactant-mediated extraction.

Plant Extracts↗

The detection and analysis of ignitable liquid residues extracted from human skin using SPME/GC.

A simple, fast, inexpensive, and sensitive technique for the detection and identification of flammable or combustible liquid residues on the skin of arson suspects is presented. The use of solid phase microextraction (SPME) for the analysis of ignitable liquid residues has been demonstrated and it is shown in this work that this technique is effective in extracting these liquid residues at extremely low quantities. Microliter quantities of controlled spikes of gasoline, diesel fuel, and charcoal lighter fluid were deposited on the hands of a volunteer and extracted after several time intervals. The SPME technique can recover very small amounts of liquid deposits on skin up to 3.5 h after exposure, depending on the class of the ignitable liquid residue used.

Chromatography, Gas↗

Developments in multiple headspace extraction.

This paper reviews new developments in multiple headspace extraction (MHE), especially its combination with two miniaturized extraction techniques, solid-phase microextraction (SPME) and single-drop microextraction (SDME). The combination of the techniques broadens the applicability of SPME and SDME to quantitative determination of analytes in complex liquid and solid matrixes. These new methods offer several advantages over traditional liquid-solid, liquid-liquid and headspace extraction techniques. The potential applications include extraction of volatiles and semivolatiles from environmental and physiological samples and from different polymer products such as medical and biomedical materials, food packaging and building materials. The theoretical principals of the techniques are also briefly reviewed.

Chromatography, Gas↗

Headspace single-drop microextraction with in-drop derivatization for aldehyde analysis.

A new technique, headspace single-drop microextraction (HS-SDME) with in-drop derivatization, was developed. Its feasibility was demonstrated by analysis of the model compounds, aldehydes in water. A hanging microliter drop of solvent containing the derivatization agent of O-2,3,4,5,6-(pentaflurobenzyl)hydroxylamine hydrochloride (PFBHA) was shown to be an excellent extraction, concentration, and derivatization medium for headspace analysis of aldehydes by GC-MS. Using the microdrop solvent with PFBHA, acetaldehyde, propanal, butanal, hexanal, and heptanal in water were headspace extracted and simultaneously derivatized. The formed oximes in the microdrop were analyzed by GC-MS. HS-SDME and in-drop derivatization parameters (extraction solvent, extraction temperature, extraction time, stirring rate microdrop volume, and the headspace volume) and the method validations (linearity, precision, detection limit, and recovery) were studied. Compared to liquid-liquid extraction and solid-phase microextraction, HS-SDME with in-drop derivatization is a simple, rapid, convenient, and inexpensive sample technique.

Journal Article↗

Determination of oak lactones in barrel-aged wines and in oak extracts by stable isotope dilution analysis.

The cis- and trans-isomers of 5-butyl-4-methyl-4,5-dihydro-2(3H)-furanone, the so-called oak lactones, are derived from oakwood, and the cis-isomer is an important contributor to wine flavour. Their deuterium-labelled forms, [2H4]cis-oak lactone and [2H4]trans-oak lactone, were synthesised from the unlabelled analogues, and were utilised in a new method employing gas chromatography-mass spectrometry to determine the concentration of these compounds in wine or extracts of oak shavings in a single analysis. The method can employ either liquid-liquid extraction or solid-phase microextraction, and is both rapid and accurate. There was some artefactual generation of cis-oak lactone during the analysis of model wine extracts of unheated oak shavings when diethyl ether extraction and injector block temperatures at or above 225 degrees C were employed.

Gas Chromatography-Mass Spectrometry↗

SPME-LC with UV detection to study delorazepam-serum albumin interactions.

Solid phase microextraction coupled to high performance liquid chromatography with UV detection (SPME/LC-UV) has been employed to study the binding of delorazepam to human serum albumin (HSA) and bovine serum albumin (BSA). The procedure could also be potentially extended to the measurement of partition coefficients between a wide variety of semi- or non-volatile compounds and matrices. The method is solvent free, simple, fast, and drawbacks of the conventional analytical techniques are avoided. Moreover, the matrix did not interfere with the measurement by binding to the fibre and the amount extracted by the fibre was negligibly small; thus it did not disturb the delorazepam-protein binding.

Anti-Anxiety Agents↗

Negligible depletion solid-phase microextraction with radiolabeled analytes to study free concentrations and protein binding: an example with [3H]estradiol.

A new method is presented that enables sensitive measurement of free concentrations of radiolabeled ligands. Additionally, protein binding of radiochemicals in complex matrixes can be determined with this new technique that combines negligible depletion solid-phase microextraction (nd-SPME) with liquid scintillation counting (LSC) as detection. [3H]Estradiol was taken as an example compound. Possible matrix effects of protein on fiber uptake kinetics were studied. No matrix effect was found, either by fouling of the fiber, or by changed uptake kinetics. The validity of the method was shown in the determination of the affinity constant (Ka) of estradiol for human serum albumin (HSA). The Ka was estimated at 8.9 x 10(4) M(-1), which corresponds well with literature values. This study shows that nd-SPME is suitable to study the free concentration and protein binding of [3H]estradiol. The method described in this paper combines the advantages of nd-SPME with the advantages of radiolabeled analytes, creating a timesaving, simple, and sensitive analytical tool that will be particularly useful in complex matrixes containing many potential interferences for chromatographic methods.

Estradiol↗

Fast temperature-programmed gas chromatography-mass spectrometry for food analysis.

Fast temperature-programmed gas chromatography (FTGC) is evaluated. A modified capillary column allowing temperature-program rates as high as 20 degrees C/s is operated with mass spectrometric detection (MSD). FTGC methods are developed for the analysis of off-flavors in water, derivatized sugars, and fatty acid methyl esters. Liquid injection and solid-phase microextraction are evaluated. Although the resolution can be somewhat lower than analysis with a traditional column, time savings are significant. Analysis times range from 2 to 4.5 min compared with 20 to 60 min for conventional methods. MSD allows for the analysis of some coeluting peaks, which allows for quantitation even when peaks coelute.

Food Analysis↗