Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Cardiac Volume”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12Linked to original sources

Relationship of cardiac chamber volume to baroreflex activity in normal humans.

The objectives of this study were to examine the effect of incremental lower body negative pressure (LBNP) on cardiac chamber volume and assess the relationship between cardiac chamber volume and baroreflex activation of the neurohormonal axis. Accordingly, echocardiographic determination of cardiac chamber volume and neurohormonal responses were studied in 14 normal subjects during incremental LBNP. LBNP -10 mm Hg decreased left atrial diameter and left ventricular systolic volume index, but did not alter heart rate, systolic or pulse pressure, or stroke volume. During LBNP -10 mm Hg, plasma norepinephrine levels increased, suggesting activation of the sympathetic nervous system. LBNP -40 mm Hg caused a significant decrease in left atrial diameter and left ventricular systolic, diastolic, and stroke volume indices. During LBNP -40 mm Hg, heart rate increased, and systolic and pulse pressure fell. With this more negative level of LBNP, norepinephrine, angiotensin II, aldosterone, and arginine vasopressin concentrations and PRA all increased. The findings that left atrial diameter decreased and plasma norepinephrine concentration increased during LBNP -10 mm Hg suggest that the sympathetic nervous system is sensitive to changes in atrial receptor activity. At higher levels of LBNP (-40 mm Hg), activation of the renin-angiotensin system and release of vasopressin were associated with a fall in left ventricular diastolic volume as well as a decrease in the pressure input to the arterial baroreceptors. Under this condition, the differential contribution of the cardiopulmonary and arterial baroreceptors to the regulation of the renin-angiotensin system and vasopressin release cannot be distinguished.

Adult↗

Regulation of fibrillar collagen gene expression and protein accumulation in volume-overloaded cardiac hypertrophy.

BACKGROUND: Interstitial collagen accumulation has been extensively demonstrated to be increased at both mRNA and protein levels in pressure-overloaded cardiac hypertrophy. However, few data are available regarding the effects of volume overload on myocardial collagens. METHODS AND RESULTS: To determine whether the alterations of collagens may occur in volume-overloaded cardiac hypertrophy, we measured collagen types I and III mRNA levels and protein accumulation in left ventricular (LV) myocardium of rats at 3, 7, and 28 days after the creation of an aortocaval (AC) shunt. Eccentric LV hypertrophy was produced in rats with AC shunting. Northern blot analysis on RNA extracted from LV tissue indicated that the steady state mRNA levels for both type I and III collagen were persistently upregulated in AC shunt rats compared with sham-operated operated control rats. In contrast, the biochemical collagen protein concentration and morphometric collagen volume fraction were comparable between sham-operated control and AC shunt rats at any study time point. Furthermore, the immunohistochemical staining of types I and III collagen and Sirius red staining on myocardial tissue sections revealed no significant alterations in the distribution or density of fibrillar collagens in AC shunt rats. Tissue collagenase activity was not different between control and AC shunt rats after 28 days. CONCLUSIONS: Cardiac volume overload increases LV collagen mRNA as does pressure overload. However, in contrast to pressure-overloaded hypertrophy, the upregulation of collagen transcriptional activity does not result in subsequent myocardial fibrosis in volume-overloaded hypertrophy due to AC shunting. Therefore, the upregulation of collagen gene expression and protein accumulation might be different in pressure-overloaded and volume overloaded hypertrophy.

Animals↗

Perioperative circulating blood volume and cardiac function in valve disease.

Circulating blood volume is important in managing fluid balance and cardiac function after surgery under cardiopulmonary bypass. Appropriate management differs among the valve disorders, but perioperative blood volume has not yet been considered. From February 2001 to March 2003, perioperative blood volume, fluid balance, cardiac index, and left ventricular stroke work index were measured in 31 patients: 10 with aortic stenosis, 9 with aortic regurgitation, 3 with mitral stenosis, and 9 with mitral regurgitation. All immediate postoperative blood volume measurements were less than preoperative values, and gradually returned to baseline. At all time points, blood volume in patients with aortic or mitral regurgitation was high, whereas it was low in those with stenosis, especially mitral stenosis. Fluid balance was positive in all patients. Postoperatively, there was a positive correlation between cardiac index and blood volume in all groups. The left ventricular stroke work index in the mitral regurgitation group was significantly higher than other groups, the aortic stenosis group was slightly lower, the mitral stenosis and mitral regurgitation groups were higher than the baseline, and the aortic regurgitation group was essentially unchanged. Thus, it is necessary to consider blood volume perioperatively in different valvular diseases to manage water balance.

Aged↗

Effects of heart rate augmentation on left ventricular volumes and cardiac output of the transplanted human heart.

The response of the donor left ventricle to atrial pacing was measured in 11 patients 12 to 64 days after cardiac transplantation. At operation seven miniature tantalum coils were placed into the midwall of the donor left ventricle so as to outline the ventricle in a 30 degrees right anterior oblique projection. Computer aided fluoroscopic analysis of marker dynamics allowed calculation of end-diastolic and end-systolic volumes, stroke volume, cardiac output, and ventricular filling characteristics. Recipients were studied in a resting, unsedated state during a period of clinical stability that did not immediately follow or precede an episode of graft rejection. Augmentation of heart rate by an average of 40 beats per minute above sinus rate produced significant reductions in end-diastolic volume (-19%), end-systolic volume (-8%), stroke volume (-31%), and the duration of systole (-19%), and diastole (-40%). Cardiac output was invariant with rate. In all patients, end-diastolic volume reduction at augmented rates was brought about by abbreviated diastolic filling as initiation of contraction occurred at an earlier point on a common, incremental filling curve. Previous studies have shown that the normal inverse relationship between heart rate and stroke volume is not available to the transplanted heart in the immediate postoperative period. The present study shows that this intrinsic mechanism becomes available to the denervated heart in the subsequent recovery period after surgery.

Cardiac Output↗

Reproducibility of cardiac stroke volume estimated by Doppler echocardiography.

Doppler echocardiography was used to measure cardiac stroke volume in 10 patients with coronary artery disease who were treated with cardioactive drugs. Stroke volume estimates were determined at the aortic orifice by multiplying area by systolic velocity integral measured both from the suprasternal and the apical approach. Recordings were done independently by 2 experienced observers on the same day and repeated once after 1 to 21 days. Analysis of variance showed that no systematic differences were introduced by the 2 observers and Doppler approaches or by measuring on different days. The coefficient of variation between any pair of measurements in each patient was 9%. This variability is probably a result of the method or spontaneous fluctuations of the stroke volume and not of the varying recording conditions. The ultrasonic method detects day-to-day changes of cardiac stroke volume larger than 20% with a probability greater than 0.95.

Adult↗

Effect of rate-adapting atrioventricular delay on stroke volume and cardiac output during atrial synchronous pacing.

The need to adjust atrioventricular delay relative to pacing rate in atrial synchronous pacemakers was assessed in eight subjects treated for complete heart block (mean age 61 +/- 3.4 years). First, an inverse relationship between heart rate and PR interval was confirmed in two groups of healthy subjects and one group of patients recovering from myocardial infarction. Due to the limitations of the available pacemakers this relationship could not be precisely reproduced. Subjects with pacemakers performed an initial exercise test on a bicycle ergometer to determine heart rate response; this information was used in part 2 to program atrioventricular delay relative to heart rate. During a second exercise test, a rate-adapting atrioventricular delay was compared to a constant atrioventricular delay of 200 ms at matched heart rates. Cardiac output was measured noninvasively by impedance cardiography. The results of part 1 showed an abnormal pattern in the response of stroke volume to exercise in seven subjects. Part 2 results demonstrated no significant difference (P greater than 0.05) between a rate-adapting atrioventricular delay and a constant delay of 200 ms for heart rate, stroke volume, cardiac output, blood pressure or Borg scale. A trend towards increased stroke volume with a rate-adapting atrioventricular delay was observed. Stroke volume was 13% larger with a rate-adapting atrioventricular delay of 125 ms at a heart rate of 125 beats/min. These results suggest that subjects with atrial synchronous pacemakers have a variable stroke volume response to exercise. It appears that in these subjects the ability to increase heart rate is the key factor for raising cardiac output during exercise.

Adult↗

Effects of rest and exercise on cardiac blood volume determinations.

AIM: The purpose of this study was to investigate the changes in blood activity during rest, exercise and recovery, and to assess its influence on left ventricular (LV) volume determination using the count-based method requiring blood sampling. METHODS: Forty-four patients underwent rest-stress radionuclide ventriculography; Tc-99m-human serum albumin was used in 13 patients (Group I), red blood cells was labeled using Tc-99m in 17 patients (Group II) in vivo, and in 14 patients (Group Ill) by modified in vivo/in vitro method. LV volumes were determined by a count-based method using corrected count rate in blood samples obtained during rest, peak exercise and after recovery. RESULTS: In group I at stress, the blood activity decreased by 12.6 +/- 5.4%, p < 0.05, as compared to the rest level, and increased by 25.1 +/- 6.4%, p <0.001, and 12.8 +/- 4.5%, p < 0.05, above the resting level in group II and III, respectively. This had profound effects on LV volume determinations if only one rest blood aliquot was used: during exercise, the LV volumes significantly decreased by 22.1 +/- 9.6%, p < 0.05, in group I, whereas in groups II and III it was significantly overestimated by 32.1 +/- 10.3%, p < 0.001, and 10.7 +/- 6.4%, p < 0.05, respectively. The changes in blood activity between stress and recovery were not significantly different for any of the groups. CONCLUSION: The use of only a single blood sample as volume aliquot at rest in rest-stress studies leads to erroneous estimation of cardiac volumes due to significant changes in blood radioactivity during exercise and recovery.

Adult↗

Measurements of cardiac stroke volume in various body positions in pregnancy and during Caesarean section: a comparison between thermodilution and impedance cardiography.

A total of 220 simultaneous pairs of measurements of cardiac stroke volume were made in twelve women before and during Caesarean section in order to compare impedance cardiography with the thermodilution method. A significantly higher coefficient of correlation was found before (r = 0.77) than during anaesthesia (r = 0.55). Further, there was a significant difference in the slope of the regression lines: before anaesthesia the slope was 1.07 and during anaesthesia with thiopentone, nitrous oxide, oxygen and suxamethonium it was 0.45. Significant changes in the intercept on the Y-axis were found before (-13.9 ml) and during anaesthesia (33.4 ml). When the uterus was displaced upwards and to the left from the 15 degrees tilt position the stroke volume and the cardiac output were increased when measured by both methods to nearly the same values as in the left lateral position. It is concluded that the impedance method is reliable for measuring cardiac stroke volume in late pregnancy under physiological conditions in the conscious patient, but that it cannot replace the thermodilution method in pharmacological studies.

Adult↗

[Simulation study of electrode configurations for cardiac stroke volume calculation by 3-dimensional finite element method].

This is a research in Kubicek electrode configurations for cardiac stroke volume calculation from the angle of Kubicek model simulation by 3-dimensional finite element method. In the process of computer simulation, we have studied, respectively, the effect of the width, thickness, and material property (specific resistance) of potential electrode band on cardiac stroke volume calculation in order to guide the choice of electrode configurations in the clinic. The simulation results showed that in Kubicek electrode configurations, its all properties of the potential electrode band affected the impedance results for cardiac stroke volume calculation, one main factor of which is the choice of the material property. Therefore, we have to attend to the choice of Kubicek electrode configurations while calculating SV by Kubicek method in order to improve the accuracy of SV calculation.

Electrodes↗

Utility and limitations of biplane transesophageal echocardiographic automated border detection for estimation of left ventricular stroke volume and cardiac output.

Recent echocardiographic ABD algorithms can estimate LV volume on-line from a single long-axis plane. The objective of this study was to assess the capability and limitations of transesophageal ABD to estimate stroke volume and cardiac output in patients before and after coronary artery bypass surgery by correlating these data with simultaneous thermodilution measurements. ABD data were acquired on-line from the transverse-plane four-chamber view and the longitudinal-plane two-chamber view and calculated by automated area-length and Simpson's rule formulas for volume. Thirty-three studies were attempted in 18 patients. Technically adequate ABD data were available in all patients from at least one view. Twenty-two (67%) of 33 studies from the four-chamber view and 27 (82%) of 33 studies from the two-chamber view were technically adequate. Cardiac output by all ABD methods was significantly correlated with thermodilution values (r range 0.72 to 0.89; SEE range 0.48 to 0.55 L/min). The two-chamber view underestimated cardiac output slightly, by an average of 0.4 L/min, whereas the four-chamber view consistently underestimated cardiac output by an average of 1.9 L/min. The area-length and Simpson's rule algorithms produced similar results. Biplane transesophageal ABD is an alternative method for estimating cardiac output; the two-chamber view in particular has potential for on-line volume determination.

Adult↗

Impact of intra-aortic balloon counterpulsation with different balloon volumes on cardiac performance in humans.

Intra-aortic balloon (IAB) counterpulsation can augment the cardiac output. However, the effect of different IAB volumes on cardiac performance has not been adequately evaluated in humans. Eighty-two patients (52 males [63%]; mean age, 65 +/- 12 years; mean body surface area [BSA], 1.8 +/- 0.2 m(2)) had IAB counterpulsation for cardiogenic shock, refractory angina, and preoperatively for high-risk cardiac surgery. Cardiac hemodynamics were prospectively studied during IAB with inflation volumes of 32 vs. 40 cc. Hemodynamic data collected included aortic pressure, pulmonary artery pressure, systemic and mixed venous oxygen saturations, and cardiac output (by Fick). Transthoracic echocardiography (TTE) was used to obtain both velocity time integrals (VTIs) and the area of the left ventricular outflow tract (LVOT). Left ventricular stroke volume was then calculated as LVOT area x VTI. Cardiac output (CO) determined by the Fick method and VTI did not differ significantly (P = NS) between the two inflation volumes (y = 0.002 + 0.97x). In a subgroup of 33 patients with BSA <or= 1.8 m(2), the CO (by VTI) was slightly lower with IAB inflation volume of 32 vs. 40 cc (P = 0.05). Overall, smaller IAB inflation volumes do not affect the hemodynamic improvement seen during IAB counterpulsation. However, in patients with smaller BSA, larger inflation volumes may further augment CO.

Aged↗

[Simulation study of Kubicek formula for cardiac stroke volume calculation by 3-dimensional finite element method].

This paper deals with the clinical application value of Kubicek formula for cardiac stroke volume calculation from the angle of Kubicek model simulation by 3-dimensional finite element method. In the process of computer simulation, we have made a comparison between the result of model simulation, the specific value of Kubicek formula for cardiac stroke volume calculation, and the theoretical value of the prescribed model. The simulation results showed that an approximately linear relationship exists between the impedance change and the blood volume change of the aorta in the model, which has proved that Kubicek formula for cardiac stroke volume calculation has great clinical application value. On the other hand, the new method has opened up a path for studying the basic theory of impedance cardiography.

Algorithms↗

Temporal stability of ambulatory stroke volume and cardiac output measured by impedance cardiography.

UNLABELLED: Recently, devices have become available that allow non-invasive measurement of stroke volume and cardiac output through ambulatory thorax impedance recording. If such recordings have adequate temporal stability, they offer great potential to further our understanding of how repeated or chronic cardiovascular activation in response to naturalistic events may contribute to cardiovascular disease. In this study, 24 h ambulatory impedance-derived systolic time intervals, stroke volume and cardiac output were measured in 65 healthy subjects across an average time span of 3 years and 4 months. Stability was computed separately for sleep and daytime recordings. To avoid confounding by differences in posture and physical activity across measurement days, temporal stability was computed using sitting activities only. During the day intraclass correlations were moderate for stroke volume (.29-.46) and cardiac output (.33-.46) and good for systolic time intervals (.55-.81). When test-retest comparison was limited to two comparable days (two work days or two leisure days), correlations for both SV (.42-.46) and CO (.43-.50) improved. CONCLUSION: Moderate long-term temporal stability is found for individual differences in ambulatory stroke volume and cardiac output measured by impedance cardiography.

Adult↗

Effect of reduced training volume on cardiac function, VO2 max, and running performance.

This study examined the physiological effects of reducing training mileage in a veteran long distance runner while increasing exercise intensity. Variables measured included stroke volume, cardiac output, maximum oxygen uptake, ventilation threshold and performance time in a 10,000 m run. For 8 weeks, training mileage was reduced from 75.8 miles per week to 42.5 miles per week including interval training twice weekly. Following the specialized training, performance time was 10 seconds faster although VO2max and heart contractility had decreased. It was concluded that distance running performance can be maintained while considerably reducing training mileage and increasing exercise intensity twice a week.

Adult↗

Comparison of impedance cardiography with thermodilution and direct Fick methods for noninvasive measurement of stroke volume and cardiac output during incremental exercise in patients with ischemic cardiomyopathy.

In the last decade, an inexpensive and simple noninvasive method (i.e., transthoracic electrical bioimpedance cardiography, has been tested in healthy subjects and patients with various heart disease for measuring stroke volume and cardiac output at rest and/or during exercise. However, the results are still controversial, especially when measurements are obtained during exercise and data on reproducibility during exercise are lacking. Twenty-five consecutive patients (20 men and 5 women, mean age 48 +/- 9 years) in sinus rhythm with documented coronary artery disease and a previous myocardial infarct were studied. Patients were divided into 2 groups. Group A had ischemic cardiomyopathy, characterized by left ventricular (LV) enlargement and LV ejection fraction depression (35 +/- 8%). Group B had normal LV dimensions and ejection fraction (62 +/- 9%). After a familiarization study, all patients underwent an exercise test with gas exchange analysis and hemodynamic measurements. Stroke volume and cardiac output were simultaneously obtained at rest and at the end of each work rate stage with 3 methods: impedance, thermodilution, and direct Fick. Group A reached a lower peak oxygen uptake (56%), peak work load (60%), and peak systolic blood pressure (69%) than group B. Cardiac output and stroke volume were significantly greater at submaximal and peak exercise in group B than in group A (p < 0.0001). There were no significant differences in stroke volume and cardiac output in the 3 techniques at any matched work rate. There was no significant difference between measurements obtained by 2 experienced observers or between those obtained on 2 exercise tests performed on 2 different days. These results demonstrate that impedance cardiography is a noninvasive, simple, accurate, and reproducible method of measurement of cardiac output and stroke volume over a wide range of workloads.

Cardiac Catheterization↗

Cardiac stroke volume: effects of athletic training.

A high capacity oxygen transport system requires a large cardiac stroke volume. This may be achieved by an increase in the systolic emptying of the heart as might occur with training programs of one to three months. Any major increase in stroke volume must be achieved by an increase in the diastolic heart volume. Only the athlete with an extraordinary degree of endurance fitness develops this change and it likely requires at least a few years of training. Some of this training may have to take place during puberty and rapid growth years. To some extent the capacity to increase stroke volume may be genetically determined. We have no information on the best way to train the heart to have a high stroke volume. The inadequate data available suggest that moderately intense interval work with supine recovery periods results in the largest possible stroke volume, but it is not known whether this is of any practical value for training athletes.

Adolescent↗