Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Capillary Action”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12Linked to original sources

Analytical applications of liquid phase chemiluminescence reactions--a review.

This paper reviews the literature on analytical applications of quantitative liquid phase chemiluminescence (CL) from 1991 to mid-1995. Other relevant reviews in this general area are also cited to provide an historical perspective. The focus is on the two major analytical techniques used in conjunction with flow-through CL detection, namely flow injection (FI) and liquid chromatography (LC). Entries have been tabulated under these two headings and are categorized in terms of the analyte, CL reaction, sample matrix and limits of detection.

Capillary Action↗

Sulfated cyclodextrins for the chiral separations of catecholamines and related compounds in the reversed electrophoretic polarity mode.

The utility of negatively charged sulfated cyclodextrins (SCD) as chiral additives (CA) in capillary electrophoresis (CE) was studied in the chiral resolution of several compounds of pharmaceutical interest, including catecholamines such as norepinephrine, epinephrine, DOPA and their precursors, phenylalanine, and tyrosine. Experiments were conducted using 10 mM sodium phosphate monobasic solution and 2% SCD adjusted to pH 3.2 with phosphoric acid. Chiral recognition mechanisms were explored using structurally related analytes including basic, acidic, and neutral compounds as well as 3,5-dinitrobenzoyl phenylglycine, phenylalanine, and homophenylalanine. The advantage of the reversed electrophoretic polarity mode for the enantioresolution of these compounds is also discussed.

Binding Sites↗

Comparison of direct infusion and on-line liquid chromatography/electrospray ionization mass spectrometry for the analysis of nucleic acids.

The applicability of ion-pair reversed-phase high-performance liquid chromatography/electrospray ionization mass spectrometry (IP-RP-HPLC/ESI-MS) and direct infusion/ESI-MS to the characterization of nucleic acid mixtures was evaluated by the analysis of the reaction products obtained from solid-phase synthesis of a 39-mer oligonucleotide. IP-RP-HPLC/ESI-MS was performed using 200 microm i.d. capillary columns packed with octadecylated, micropellicular poly(styrene-divinylbenzene) particles and applying gradients of acetonitrile in 50 mM triethylammonium bicarbonate (TEAB). Three different solvent systems were utilized for direct infusion/ESI-MS with removal of metal cations by on-line cation exchange: (1) 10 mM triethylamine (TEA) in 50% aqueous acetonitrile, (2) 2.2 mM TEA, 400 mM hexafluoro-2-propanol (HFIP) in 20% aqueous methanol and (3) 50 mM TEAB in 10% aqueous acetonitrile. Owing to its separation capability, the highest selectivity and specificity were achieved with IP-RP-HPLC/ESI-MS, which, apart form the 39-mer target sequence, allowed the identification of two isobutyryl-protected target sequences and a 10-mer and 20-mer failure sequence. Direct infusion/ESI-MS with TEA-acetonitrile or TEA-HFIP-methanol as solvent revealed signals for the 39-mer in the m/z range 700-1600. The presence of derivatives containing one, two, three and four isobutyryl groups indicated that the hydrolysis of the protecting groups after solid-phase synthesis was not complete. Failure sequences could not be identified by direct infusion/ESI-MS under conditions favoring multiple charging of the analytes owing to the high chemical background and coincidental overlapping of m/z signals. However, efficient charge state reduction upon addition of carbonic acid to the electrosprayed solvent shifted the signals of the 39-mer and derivatives to m/z values >2400 and allowed the detection of seven different failure sequences, ranging from the 8-mer to the 23-mer, in the mixture.

Base Sequence↗

Study of an enzyme membrane reactor with immobilized fumarase for production of L-malic acid.

The conversion of fumaric acid into L-malic acid by fumarase immobilized in a membrane reactor was analyzed experimentally. The enzyme was entrapped in asymmetric capillary membranes made of polysulfone. The performance of the reactor was evaluated in terms of conversion degree, reaction rate, and stability. The influence of operating conditions, such as amount of immobilized enzyme, substrate concentration, residence time, and axial flow rate, were investigated. The kinetic parameters K(m), V(max), and k(+2) were also measured. The stability of the immobilized enzyme was very good, showing no activity decay during more than 2 weeks of continuous operation.

Animals↗

Enantioseparations by capillary electrochromatography.

The review summarizes recent developments in enantioseparations by capillary electrochromatography (CEC). Selected fundamental aspects of CEC are discussed in order to stress those features which may allow the success of this technique in the competitive field of enantioseparations. In addition, the comparative characteristics of the different modes of chiral CEC and the stationary phases are presented. The effects of the characteristics of the stationary and liquid phases and operational conditions on the separation results are discussed. Finally, some future trends are briefly addressed.

Buffers↗

Strategy for selection of methods for separation of bioparticles from particle mixtures.

The desired product of bioprocesses is often produced in particulate form, either as an inclusion body (IB) or as a crystal. Particle harvesting is then a crucial and attractive form of product recovery. Because the liquid phase often contains other bioparticles, such as cell debris, whole cells, particulate biocatalysts or particulate by-products, the recovery of product particles is a complex process. In most cases, the particulate product is purified using selective solubilization or extraction. However, if selective particle recovery is possible, the already high purity of the particles makes this downstream process more favorable. This work gives an overview of typical bioparticle mixtures that are encountered in industrial biotechnology and the various driving forces that may be used for particle-particle separation, such as the centrifugal force, the magnetic force, the electric force, and forces related to interfaces. By coupling these driving forces to the resisting forces, the limitations of using these driving forces with respect to particle size are calculated. It shows that centrifugation is not a general solution for particle-particle separation in biotechnology because the particle sizes of product and contaminating particles are often very small, thus, causing their settling velocities to be too low for efficient separation by centrifugation. Examples of such separation problems are the recovery of IBs or virus-like particles (VLPs) from (microbial) cell debris. In these cases, separation processes that use electrical forces or fluid-fluid interfaces show to have a large potential for particle-particle separation. These methods are not yet commonly applied for large-scale particle-particle separation in biotechnology and more research is required on the separation techniques and on particle characterization to facilitate successful application of these methods in industry.

Biological Products↗

Ultra scale-down studies of the effect of flow and impact conditions during E. coli cell processing.

The ability to recover cells from a fermentation broth in an intact form can be an important criterion for determining the overall performance of a recovery and purification sequence. Disruption of the cells can lead to undesired contamination of an extracellular product with intracellular components and vice versa loss of intracellular products may occur. In particular, the value of directed location of a product in the periplasmic space of say Escherichia coli (E. coli) would be diminished by such premature non-selective cell disruption. Several options exist for cell recovery/removal; namely centrifugation, in batch or continuous configuration, filtration or membrane operations, and in selected cases expanded beds. The choice of operation is dependant on many variables including the impact on the overall process sequence. In all cases, the cells are exposed to shear stresses of varying levels and times and additionally such environments exist in ancillary operations such as pumping, pipe flow, and control valves. In this study, a small-scale device has been designed to expose cells to controlled levels of shear, time and impact in a way that seeks to mimic those effects that may occur during full-scale processes. The extent of cell breakage was found to be proportional to shear stress. An additional level of breakage occurred due to the jet impacting on the collecting surface. Here it was possible to correlate the additional breakage with the impact velocity, which is a function of the distance that the jet travels before meeting the collection surface and the initial jet velocity.

Bioreactors↗

Hyperaemic response in the skin microcirculation of patients with chronic venous insufficiency.

The capacity of the microcirculation in the liposclerotic skin of patients with chronic venous insufficiency to vasodilate in response to pilocarpine electrophoresis was assessed using laser Doppler fluxmetry. Pilocarpine induces vasodilation by direct action on capillaries; other methods of vasodilatation, such as heating of the skin, act by a number of pathways including a neurogenic one. Thirty patients with lipodermatosclerosis and chronic venous insufficiency and 20 control subjects were studied. There was no difference in peak vasodilatation following pilocarpine electrophoresis in the two groups. The median (interquartile range) peak flux in patients was 665 (382-1025) units and in controls 765 (452-975) units (95 per cent confidence interval of difference--270 to 150 units, P = 0.5). This suggests that the capillaries in the liposclerotic skin of patients with chronic venous insufficiency have a normal capacity to vasodilate.

Aged↗

Detection of abnormal haemoglobin by capillary electrophoresis and structural identification.

Haemoglobin obtained from a male adult Ghanian with retinopathy, which was probably caused by haemoglobinopathy was analysed by capillary electrophoresis (CE) for clinical diagnosis. Two major peaks, which were in the ratio of nearly one, were detected. The elution times of these peaks (HbXI and HbXII) were faster than that of normal haemoglobin (HbA). The existence of two different abnormal types of haemoglobin was clear in the patient blood. The following sequence analysis revealed that the first peak (HbXI) was HbC and the second (HbXII) was HbS on the electropherogram, and that the patient was a heterozygote of HbS and HbC (HbSC disease). One of the diagnostic processes in a haemoglobin disease was shown by the combined use of CE, HPLC and a protein sequencer.

Adult↗

UV-transparent, replaceable agarose gels for molecular-sieve (capillary) electrophoresis of proteins and nucleic acids.

Gels of methoxylated agarose (gelling point 25.6 degrees C) and other low-melting agarose derivatives compare favorably with cross-linked polyacrylamide gels for capillary and slab molecular-sieve electrophoresis of proteins and DNA. These agarose gels can be pressed out of the capillary following a run and replaced by an agarose solution with a temperature of 35-40 degrees C. Gelation occurs upon lowering temperature and the same capillary can thus be reused for another analysis with a fresh gel. The methoxylated, non UV-absorbing agarose gels are, accordingly, replaceable, which makes them very attractive for series analyses with modern, automated capillary electrophoresis apparatus. The high resolution of these agarose gels is demonstrated with a separation of an albumin sample into monomers, dimers, trimers, tetramers, pentamers, hexamers, heptamers, and of DNA fragments.

Autoanalysis↗

Separation and identification of proteins obtained from Agkistrodon acutus snake venom by capillary zone electrophoresis and laser desorption/ionization mass monitoring.

Fractions of seven protein principles with fibrinolytic or thrombin-like activities obtained from Agkistrodon acutus snake venom purified by two steps of normal pressure chromatography were separated further by capillary zone electrophoresis (CZE). Mass determination for these fractions were achieved by performing laser desorption/ionization mass monitoring (LDIM). The comparative study between CZE and LDIM on the separation of these fractions was made.

Agkistrodon↗

High-resolution separation of PCR product and gene diagnosis by capillary gel electrophoresis.

High-resolution separation of a PCR product from a mixture of DNA restriction fragments was achieved using capillary gel electrophoresis. The capillary gel electrophoretic separation gives an excellent resolution of two fragments of the 500-bp PCR product and the 506-bp DNA fragment, which differs by only 6 bp, and the complete separation of a broader chain length range of DNA afragments up to 12 kbp within 20 min. The plate number of gel-filled capillary was achieved to be 2 million plates per meter. Capillary gel electrophoresis is applied to the gene diagnosis for heart disease through apolipoprotein E genotyping. The advantages and limitations of capillary gel electrophoresis in the application to PCR analysis and DNA diagnosis are discussed.

Apolipoproteins E↗

Near-IR dyes in three-color volumetric capillary cytometry: cell analysis with 633- and 785-nm laser excitation.

Several fluorescent dyes that absorb in the near-infrared are described. The photostability and aggregation properties of the dyes were examined. Two of the dyes, BHMP and BHDMAP, emit at 805 nm and were useful dyes for protein labeling. A dual-laser, three-color scanning instrument was constructed. CD3+CD4+ and CD3+CD8+ populations were enumerated in undiluted, whole blood based on the fluorescence of Cy5, Cy5.5 and BHMP.

Antigens, CD↗

Fast and high resolution analysis of human serum transferrin by high performance isoelectric focusing in capillaries.

Human serum transferrin is a mixture of isoforms (isoproteins) having different amounts of carbohydrates. Each isoform may exist in iron-free and iron-complexed molecular form. The genetic variations in different populations increase the number of combinations of the different forms of transferrin. To resolve the many components in transferrin preparations, the new high performance capillary technique was employed for isoelectric focusing. Iron-free transferrin and transferrin samples of known iron content were examined. The above method gives an exceptionally rapid analysis (within 15-25 min) of small amounts of samples (less than 1 microgram protein) and as good as or better resolution than other isoelectric focusing techniques previously used for transferrin analysis. By monitoring the focused protein zones at both 280 and 460 nm the molecular forms of transferrin (iron-free, monoferric and differic complexes) can easily be identified. Both steps of isoelectric focusing in capillaries (i.e., prefocusing and mobilization) can be used for analysis. We observed that chelating agents (e.g., carrier ampholytes, nitrilotriacetate) may release iron from microsyringes having metal pistons causing the formation of iron-transferrin complexes.

Capillary Action↗

Selective influencing of the migration time of SO4(2-) by forming neutral species with Pb2+ in capillary zone electrophoresis.

Organic and inorganic anions are analyzed using capillary zone electrophoresis with indirect fluorescence detection. As electrolyte 2,5-dihydroxybenzoic acid is used. By adding Pb2+ to the electrolyte the migration time of SO4(2-) can be selectively influenced and the separation of Cl- and SO4(2-) considerably improved. The fluorescence intensity of 2,5-dihydroxybenzoic acid increases in the presence of Pb2+ up to a concentration of 6*10(-4) mol/L Pb2+. Limits of detection in the lower mumol/L range were obtained.

Anions↗

DNA digest analysis with capillary electrophoresis.

DNA digest analysis with polymer-filled capillaries in capillary electrophoresis is described. The samples analyzed consisted of commercially available standards including a 100 base pair ladder with repeating units up to 2000 base pairs. Three DNA digests covered the most common small fragment ranges: up to 600 base pairs, up to 1500 base pairs and from 100 to 2500 base pairs. All samples were separated by traditional slab gel electrophoresis at various agarose concentrations and by automated capillary electrophoresis. The capillary electrophoretic separations were achieved with noncross-linked polyacrylamide from 6% monomer solutions. The acrylamide was polymerized inside the capillary, which was coated with a methacryloxysilane to insure binding of the polyacrylamide to the capillary wall. With 6% columns, excellent separations were observed up to 600 base pairs with base line resolution for fragments differing in less than 10 base pairs. Resolution power for fragments between 600 and 2200 decreased to about 300 base pairs. Compared to slab gels, capillary electrophoresis achieved better resolution in the low fragment range, whereas with the reported column composition, slab gels were superior above 600 base pairs. Fast access to the analysis of a specific sample, automation, and a larger dynamic range for sample load are further benefits of a DNA digest analysis by capillary electrophoresis.

Autoanalysis↗