Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “biosensing”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11Linked to original sources

Calcified nanostructured silicon wafer surfaces for biosensing: effects of surface modification on bioactivity.

The growth of known biologically-relevant mineral phases on semiconducting surfaces is one strategy to explicitly induce bioactivity in such materials, either for sensing or drug delivery applications. In this work, we describe the use of a spark ablation process to fabricate deliberate patterns of Ca(10)(PO4)6(OH)2 on crystalline Si (calcified nanoporous silicon). These patterns have been principally characterized by scanning electron microscopy in conjunction with elemental characterization by energy dispersive x-ray analysis. This is followed by a detailed comparison of the effects of fibroblast adhesion and proliferation onto calcified nanoporous Si, calcified nanoporous Si derivatized with alendronate, as well as control samples of an identical surface area containing porous SiO2. Fibroblast adhesion and proliferation assays demonstrate that a higher density of cells grow on the Ca3(PO4)2/porous Si/SiO2 structures relative to the alendronate-modified surfaces and porous Si/SiO2 samples.

Biosensing Techniques↗

High levels of dioxin-like potential in cigarette smoke evidenced by in vitro and in vivo biosensing.

Cigarette smoke contains low levels of agonists for the aryl hydrocarbon receptor (AhR; also called the dioxin receptor). However, little is understood about the whole potential of cigarette smoke for activating AhR. In this report, we evaluated the total "dioxin-like" activity of cigarette smoke using in vitro and in vivo reporter systems. Cigarette smoke extract (CSE) was prepared from seven cigarette brands (1-20 mg tar content) and subjected to in vitro bioassay based on the xenobiotic-responsive element (XRE) as the sensor and secreted alkaline phosphatase (SEAP) as the reporter. Exposure of reporter cells to CSE triggered activation of XRE in a dose-dependent manner, which was suppressed by functional inhibition of AhR. Direct, brief exposure of the cells to cigarette smoke similarly induced activation of XRE. Using 2,3,7,8-tetrachlorodibenzo-p-dioxin (2,3,7,8-TCDD) as the standard, the XRE-activating potential (XAP) of individual smoke was evaluated quantitatively. Positive correlation was observed between the tar content and XAP values. The XAP values estimated were extremely high with a range from 18.5 to 51.2 ng 2,3,7,8-TCDD equivalent per cigarette. To further estimate XAP of cigarette smoke in vivo, we generated transgenic reporter mice that secrete SEAP under the control of XRE. After exposure of the mice to smoke, serum levels of SEAP were significantly elevated within 12 hours, peaked at 24 hours, and declined thereafter. These results evidenced for the first time that cigarette smoke has unexpectedly high dioxin-like potential that triggers the AhR-XRE pathway in vitro and in vivo.

Alkaline Phosphatase↗

Short- and intermediate-term clinical outcomes from direct myocardial laser revascularization guided by biosense left ventricular electromechanical mapping.

BACKGROUND: Direct myocardial revascularization (DMR) has been examined as an alternative treatment for patients with chronic refractory myocardial ischemic syndromes who are not candidates for conventional coronary revascularization. Methods and Results-We used left ventricular electromagnetic guidance in 77 patients with chronic refractory angina (56 men, mean age 61+/-11 years, ejection fraction 0.48+/-0.11) to perform percutaneous DMR with an Ho:YAG laser at 2 J/pulse. Procedural success (laser channels placed in prespecified target zones) was achieved in 76 of 77 patients with an average of 26+/-10 channels (range 11 to 50 channels). The rate of major in-hospital cardiac adverse events was 2.6%, with no deaths or emergency operations, 1 patient with postprocedural pericardiocentesis, and 1 patient with minor embolic stroke. The rate of out-of-hospital adverse cardiac events (up to 6 months) was 2.6%, with 1 patient with myocardial infarction and 1 patient with stroke. Exercise duration after DMR increased from 387+/-179 to 454+/-166 seconds at 1 month and to 479+/-161 seconds at 6 months (P=0.0001). The time to onset of angina increased from 293+/-167 to 377+/-176 seconds at 1 month and to 414+/-169 seconds at 6 months (P=0.0001). Importantly, the time to ST-segment depression (>/=1 mm) also increased from 327+/-178 to 400+/-172 seconds at 1 month and to 436+/-175 seconds at 6 months (P=0.001). Angina (Canadian Cardiovascular Society classification) improved from 3.3+/-0.5 to 2.0+/-1.2 at 6 months (P<0.001). Nuclear perfusion imaging studies with a dual-isotope technique, however, showed no significant improvements at 1 or 6 months. CONCLUSIONS: Percutaneous DMR guided by left ventricular mapping is feasible and safe and reveals improved angina and prolonged exercise duration for up to a 6-month follow-up.

Adult↗

Nanosystems for biosensing: multianalyte immunoassay on a protein chip.

This chapter describes the construction of addressable two-dimensional (2D) microarrays via the random fluidic self-assembly of metallic particles and the use of these arrays as platforms for constructing protein chips for bioassays. These arrays will be useful as platforms for constructing protein chips for bioassays in a broad range of applications. The basic units in the assembly are microfabricated particles, which carry a straightforward visible code, and the corresponding array template patterned on a glass substrate. On one face, the particles consist of a hydrophobic and magnetic Ni-polytetrafluoroethylene (Ni-PTFE) composite layer; the other face has a gold layer that was modified for biomolecular attachment. We use photoresist patterning to create an array template with spatially discrete microwells into which an Ni-PTFE hydrophobic composite layer and a hydrophobic photoadhesive coating are electrodeposited. After biomaterial attachment and binding processes in bulk, the particles are randomly self-assembled onto the lubricated bonding sites on the chip substrate. This self-assembly process is driven by a combination of magnetic, hydrophobic, and capillary interactions. The encoding symbol carried by each particle is used to identify the target attached to the particle surface. This model system demonstrates the utility of the protein chip array for conducting simultaneous multianalyte immunoassays of human immunoglobulins (IgA, IgG, and IgM).

Animals↗

Construction and evaluation of nagR-nagAa::lux fusion strains in biosensing for salicylic acid derivatives.

The NagR protein is a response regulatory protein found in the bacterium Ralstonia sp. U2 that is involved in sensing for salicylic acid and the subsequent induction of the operon just upstream of its gene. The genes encoded for in this operon are involved in the degradation of salicylic acid. Escherichia coli strain RFM443 carrying a fusion of the Photorhabdus luminescens luxCDABE operon with the nagR gene and upstream region of the nagAa gene was constructed and characterized with respect to its optimum temperature, its response time and kinetics, and its ability to detect numerous benzoic acid derivatives. Although capable of detecting 0.5 mM salicylic acid at any temperature between 28 and 40 degrees C, this E. coli strain, labeled DNT5, showed its greatest relative activity at 30 degrees C, i.e., the temperature at which the largest induction was seen. Furthermore, experiments done with numerous benzoic acid derivatives found the NagR protein to be responsive to only a few of the compounds tested, including salicylic acid and 3-methyl salicylic acid, and acetyl salicylic acid was the strongest inducer. The lower limits of detection for these compounds with E. coli strain DNT5 were also established, with the native inducer, salicylic acid, giving the most sensitive response and detectable down to a concentration of about 2 microM. A second lux fusion plasmid was also constructed and transformed into an NahR background, Pseudomonas putida KCTC1768. Within this strain, NAGK-1768, the supplemental activity of the NahR protein on the nagAa promoter, was shown to extend both the range of chemicals detected and the sensitivity.

Benzene↗

Demonstration of a new biosensing concept for immunodiagnostic applications based on change in surface conductance of antibodies after biomolecular interactions.

We report an important observation that the surface conductivity of antibody layer immobilized on polylysine-coated glass substrate decreases upon the formation of complex with their specific antigens. This change in conductivity has been observed for both monoclonal and polyclonal antibodies. The conductance of monoclonal mouse IgG immobilized on polylysine-coated glass substrate changed from 1.02x10(-8) ohm(-1) to 1.41x10(-11) ohm(-1) at 10 V when complex is formed due to the specific biomolecular interactions with rabbit anti-mouse IgG F(ab')(2). Similar behavior was observed when the same set up was tested in two clinical assays: (1) anti-Leishmania antigen polyclonal antibodies taken from Kala Azar positive patient serum interacting with Leishmania promastigote antigen, and (2) anti-p21 polyclonal antibodies interacting with p21 antigen. The proposed concept can represent a new immunodiagnostic technique and may have wide ranging applications in biosensors and nanobiotechnology too.

Animals↗

Biosensing paraoxon in simulated environmental samples by immobilized organophosphorus hydrolase in functionalized mesoporous silica.

There is a critical need for highly sensitive, cost-effective sensors to conduct ecological analyses for environmental and homeland security-related applications. Enzyme biosensors, which are currently gaining acceptance for environmental monitoring applications, need improvements to deliver faster measurements with stabilized sensing elements, e.g., enzymes. We report here on a method which significantly overcomes this difficulty, and demonstrate its application in a biosensor for aquatic environmental applications. A fast-responding and stable biosensor was developed via immobilization of organophosphorus hydrolase (OPH) in functionalized mesoporous silica (FMS) with pore sizes in tens of nanometers. The OPH-FMS composite was held on glassy carbon electrode by a dried Nafion gel and FMS protected OPH from Nafion-resulted activity loss. The resulting enzyme biosensor, when integrated with an electrochemical instrument, responded rapidly to low paraoxon concentration and achieved steady-state current in less than 10 s, with a detection limit of 4.0x10(-7) M paraoxon. The biosensor was tested for detection of paraoxon in simulated environmental samples, under wide-ranging physicochemical conditions. Results clearly indicate high recovery efficiencies in aqueous solutions (96 to 101%) at different pH, total organic carbon, total dissolved solids, and total suspended solids, and demonstrate the ability of the biosensor unit to continuously monitor paraoxon in aqueous conditions similar to those found in river and lake systems.

Aryldialkylphosphatase↗

[Photopolymers as an immobilized matrix in biosensing].

Biosensors are perspective devices for analysis of substances in chemistry, biological chemistry, medicine, biotechnology and also for environment status monitoring. Their advantages are compact size, short time of analysis, display high response and simplicity in usage. The working characteristics of biosensors often depend on efficacy of a biological stuff immobilization on the surface of transducer. In this context there is a need for development of immobilization methods capable to provide for execution of the following demands: 1) compatibility of this process with technology of building transducer; 2) simplicity in fulfillment, cheapness and expressness at manufacture of biomembranes; 3) ability to provide the maximal safety of a biological stuff activity and its high adhesion to a surface of transducer; 4) reproducibility at serial application and capacity of standardizing. Usage of photocrosslinked and photopolymerized compound at the immobilization of a biological stuff allows to provide execution of the listed above demands. The present review is devoted to features of application of the given class of compound at building of biosensors.

Biosensing Techniques↗

Non-mediated glucose biosensing using nanostructured TiO2.

Insufficient insulin production in diabetics can be controlled by discontinuous measurement and insulin therapy. Ideally, an artificial pancreas system would be a closed loop system measuring glucose levels, and administering insulin as required, to minimise patient contribution. This paper presents an investigation into the use of titanium dioxide as an electrochemical transducer for the detection of hydrogen peroxide. Hydrogen peroxide is the product of glucose oxidation by the enzyme glucose oxidase in the presence of oxygen. The results show that peroxide can be quantitatively detected by electrochemical reduction on titanium dioxide electrodes without interference due to dissolved oxygen. When tested for the indirect amperometric measurement of glucose (with free glucose oxidase) it was found that the electrodes responded linearly over the range of glucose concentration found in human blood. With further development, these electrodes may be suitable for implantable glucose sensors.

Biosensing Techniques↗

Evaluation of the acute and chronic safety of the biosense injection catheter system in porcine hearts.

Direct myocardial injection of therapeutic agents has been explored as a new method for myocardial revascularization. The integration of a 3D electromechanical mapping catheter with a retractable injection needle should allow for intramyocardial injection to identified sites, obviating the need for open heart surgery. This study assessed the procedural safety and performance characteristics of a novel guided catheter-based transendocardial injection system. The electromagnetic guidance system was coupled with a retrievable 27G needle for left ventricular endocardial injection. Using this system, we injected, transendocardially, methylene-blue (MB) dye tracer at a volume of 0.1 or 0.2 ml per injection in eight normal pigs. Animals were sacrificed acutely, at 1, 3, and 7 days (two animal in each time). Three animals served as controls. The injections were followed by coronary angiography and echocardiogram to assess possible ventricular or coronary perforation and wall motion abnormalities. CK-MB levels were measured up to 24 hr following the procedure. The animals were sacrificed at the assigned time for gross and histopathology evaluation. A total of 101 injections were made in all regions of the heart except the apex and the mitral valve. No animal died as a result of the mapping or injection procedures. Vital signs did not change relative to baseline after the mapping and injection procedures. CK-MB values did not increase over time and there was no evidence of sustained arrhythmia or hemodynamic compromise. There was no evidence of left ventricular or coronary perforation, global or regional wall motion abnormalities, or hemopericardium. On histologic evaluation, the estimated volume of tissue staining was greater than the volume of the injected MB dye due to dispersion of the injectate in the interstitial and intracellular fluid compartments. It is concluded that using this magnetic guidance catheter-based navigational system, it is feasible and safe to perform the transendocardial injection procedure. Thus, if it is determined that direct intramyocardial injection of drugs is a valid therapeutic strategy, this approach offers a clear advantage over surgically based transepicardial injection procedures. Cathet. Cardiovasc. Intervent. 48:447-453, 1999.

Animals↗

Aptasensors--the future of biosensing?

Aptamers are artificial nucleic acid ligands that can be generated against amino acids, drugs, proteins and other molecules. They are isolated from combinatorial libraries of synthetic nucleic acid by an iterative process of adsorption, recovery and reamplification. Aptamers, first reported in 1990, are attracting interest in the areas of therapeutics and diagnostics and offer themselves as ideal candidates for use as biocomponents in biosensors (aptasensors), possessing many advantages over state of the art affinity sensors. The properties of aptamers, their applicability to biosensor technology, current research and future prospects are addressed in this short review.

Antibodies↗