Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “SHAPE”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11Linked to original sources

A quantitative study of the role of F-actin in producing neutrophil shape.

Neutrophils change shape from round to polar and sequentially polymerize/depolymerize actin following chemotactic peptide activation in suspension. To study the relationship between changes in F-actin content and shape we altered the kinetics/extent of actin polymerization and depolymerization with tBOC peptide, cytochalasin D (CD), and low-dose FMLP, and determined the effect of these alterations on the temporal sequence of changes in neutrophil shape. F-actin was measured by FACS analysis of NBDphallacidin-stained cells and expressed as relative fluorescent intensity (RFI) compared to control (RFI = 1.00). Shape was determined by scanning electron microscopy. FMLP causes serial polymerization/depolymerization of actin (RFI = 1.00 +/- 0.04, 1.60 +/- 0.21, 1.10 +/- 0.18, and 1.05 +/- 0.14) associated with four distinct shapes (round-smooth, round-ruffled, blebbed, and polar) noted at 0, 30, 90, 300 sec respectively. Since blebbed and polar shapes appear concurrent with depolymerization and following polymerization, we determined whether depolymerization is required for polarization of cells. The kinetics of depolymerization were: (1) accelerated by tBOC addition at 45 sec, and (2) slowed by high concentrations of FMLP (greater than 10-7M) (300 sec RFI = 1.46). Neither change altered the time course of shape change. To determine whether duration of actin polymerization defines shape, polymerization was halted by addition of tBOC at 5, 10, 20, 30 sec after FMLP to block actin polymerization and shape was monitored at 300 sec. TBOC added 5-20 sec after FMLP limited neutrophil shape change to the blebbed form, while tBOC addition 30 sec following FMLP resulted in a polar shape at 300 sec. To determine whether the extent of actin polymerization affects the shape change sequence, polymerization was limited by (1) inhibition of polymerization with CD, (2) exposure of cells to low concentrations of FMLP (less than 10-9 M), and (3) interruption of polymerization with tBOC. Actin polymerization to RFI less than 1.35-fold basal results in blebbed shape; polymerization greater than 1.35-fold basal yields polar shape. The data show: (1) the human neutrophil demonstrates intermediate shapes when activated by chemotactic peptide, (2) depolymerization of F-actin does not determine shape, and (3) blebbed shape appears when actin polymerizes for greater than 5 sec; polar shape with polymerization greater than or equal to 30 sec to RFI greater than 1.35-fold basal. The data suggest actin polymerization is required for, and extent of polymerization determines, the shape of human neutrophils.

Actins↗

Selective attention to conjunctions of color and shape of alphanumeric versus non-alphanumeric stimuli: a comparative electrophysiological study.

We compared multi-dimensional selection on the basis of the color, the global shape and the local shape of alphanumeric (letters) and non-alphanumeric (non-letters) stimuli. We investigated whether letters are selected on the basis of name codes or on the basis of highly familiar local shape codes. Participants responded to a single conjunction of color, global shape and local shape occurring in a randomized stream of other conjunctions of these attributes. Dependent variables were reaction time and measures derived from event-related brain potentials (onset latencies and peak amplitudes of the occipital selection negativity, SN). The SN results showed that, for both letters and non-letters, color and global shape were selected first and local shape was selected later. Reaction times were faster, and SN to the local shape occurred earlier for letters than for non-letters. The SN to the local shape of letters was larger than the SN to the local shape of non-letters. In contrast, the SN to the global shape of letters was smaller than the SN to the global shape of non-letters. Selection of the global shape of letters, but not of non-letters, depended on whether they occurred in the relevant color. Selection of the color of both letters and non-letters was independent of shape relevance, and selection of the local shape of both letters and non-letters was independent of color relevance. These results suggest that, (1) both letter and non-letter shapes are initially analyzed in a feature-specific manner; and (2) letters are selected for task-directed processing on the basis of highly familiar local shape codes and not on the basis of name codes.

Adult↗

Polymeric triple-shape materials.

Shape-memory polymers represent a promising class of materials that can move from one shape to another in response to a stimulus such as heat. Thus far, these systems are dual-shape materials. Here, we report a triple-shape polymer able to change from a first shape (A) to a second shape (B) and from there to a third shape (C). Shapes B and C are recalled by subsequent temperature increases. Whereas shapes A and B are fixed by physical cross-links, shape C is defined by covalent cross-links established during network formation. The triple-shape effect is a general concept that requires the application of a two-step programming process to suitable polymers and can be realized for various polymer networks whose molecular structure allows formation of at least two separated domains providing pronounced physical cross-links. These domains can act as the switches, which are used in the two-step programming process for temporarily fixing shapes A and B. It is demonstrated that different combinations of shapes A and B for a polymer network in a given shape C can be obtained by adjusting specific parameters of the programming process. Dual-shape materials have already found various applications. However, as later discussed and illustrated by two examples, the ability to induce two shape changes that are not limited to be unidirectional rather than one could potentially offer unique opportunities, such as in medical devices or fasteners.

Journal Article↗

Analysis of ventricular shape by echocardiography in normal fetuses, newborns, and infants.

Qualitative and quantitative changes in left ventricular shapes were analyzed in 14 normal fetuses, 29 normal newborns, and 12 normal infants. Qualitative observations demonstrated that most fetuses and newborns with dominant right ventricles had flattened or even indented interventricular septae, which changed left ventricular shape into an ellipse. In contrast, left ventricular shapes in infants were round, similar to shapes described in older children and adults. When changes in shape or septal distortions were gross, interobserver agreement was 100%; when changes were less altered from a circular shape, interobserver agreement was 78%. To avoid subjective misinterpretations, quantitative analyses were performed, including M mode echocardiographic comparisons of right ventricular/left ventricular dimensions and left ventricular cavity anterior-posterior/lateral diameters, as well as Fourier analysis of digitized tracings of the entire left ventricular shape. The right ventricular/left ventricular ratio, determined by M mode echocardiography, showed significant differences between fetuses (1.07 +/- 0.07) and newborns (0.62 +/- 0.12) (p less than .001). Infants had a significantly lower right ventricular/left ventricular ratio (0.45 +/- 0.01) when compared with newborns (p less than .01). Ratios of left ventricular anterior-posterior/lateral diastolic diameters were significantly lower (p less than .001) in newborns (0.66 +/- 0.08) when compared with those of infants (0.82 +/- 0.10). All diameters tended to increase (toward roundness) with systole and with aging. Fourier analysis allowed evaluation of the entire left ventricle, including that portion of the septum that qualitatively appeared most indented and could not be analyzed by either of the above techniques. Shape factor derived from idealized shapes ranging from a circle to an indented ellipse allowed comparison with digitized left ventricular tracings. This technique allowed accurate quantitation of the observed changes in shape. Fetuses had the highest diastolic shape factor (7.47 +/- 0.92), whereas infants' shape factors were lowest (2.12 +/- 0.41). A tendency toward roundness and loss of distortion occurred with aging. Systolic shape factor was lower with aging in each group studied. The Fourier technique used in this study allows evaluation of an arbitrarily large number of components of a shape, and thus a complete description of that shape is permitted. Comparisons of right ventricular/left ventricular diastolic dimensions and left ventricular anterior-posterior/lateral comparisons are subsets of this technique, which allow evaluation of only two points (circular component-first harmonic) or four points (elliptical component-second harmonic) of an overall shape.(ABSTRACT TRUNCATED AT 400 WORDS)

Echocardiography↗

A theory of shape constancy based on perspective invariants.

Shape constancy refers to the phenomenon in which the percept of the shape of a given object remains constant despite changes in the shape of the object's retinal image. The phenomenon of shape constancy is considered from historical, theoretical and empirical perspectives in this paper. First, four prior theories are discussed; specifically, (1) Helmholtzian theory, which assumes that shape constancy is achieved by taking an object's orientation into account, (2) Gestalt theory, which assumes that shape constancy involves a relationship between the perceived shape and perceived orientation of an object, (3) Gibsonian theory, which assumes that shape constancy is based on projective invariants and (4) multiple view theory, which assumes that shape constancy is achieved by memorizing a large set of different views of the object. It is shown, by an analysis of the prior literature, that none of these theories can actually explain the phenomenon of shape constancy. A new theory, which is based on new perspective invariants of a flat shape, is then proposed. The new Perspective Invariants Theory can account for all prior shape constancy experiments. New experiments, testing predictions of the Perspective Invariants Theory are then described. These experiments showed that: (1) a novel shape can be matched with its single perspective image in the absence of depth cues, (2) perceptual processing of shape is impaired when the range of possible values of tilt is wide, (3) perceptual processing of shape is not affected by the width of the range of possible values of slant. These results support predictions of Perspective Invariants Theory.

Algorithms↗

Quantification of shape variation of prostate and seminal vesicles during external beam radiotherapy.

PURPOSE: The prostate is known to translate and rotate under influence of rectal filling changes and many studies have addressed the magnitude of these motions. However, prostate shape variations also have been reported. For image-guided radiotherapy, it is essential to know the relative magnitude of translations, rotations, and shape variation so that the most appropriate correction strategy can be chosen. However, no quantitative analysis of shape variation has been performed. It is, therefore, the purpose of this article to develop a method to determine shape variation of complex organs and apply it to determine shape variation during external beam radiotherapy of a GTV (gross tumor volume) consisting of prostate and seminal vesicles. METHODS AND MATERIALS: For this study, the data of 19 patients with prostate cancer were used. Each patient received a planning computed tomography (CT) scan and 8-12 (11 on average) repeat CT scans that were made during the course of conformal radiotherapy. One observer delineated the GTV in all scans, and volume variations were measured. After matching the GTVs for each patient for translation and rotation, a coverage probability matrix was constructed and the 50% isosurface was taken to determine the average GTV surface. Perpendicular distances between the average GTV and the individual GTVs were calculated for each point of the average GTV, and their variation was expressed in terms of local standard deviation (SD). The local SDs of the shape variation of all 19 patients were mapped onto a reference case by matching and morphing of the individual average GTVs. Repeated delineation of the GTV was done for 6 patients to determine intraobserver variation. Finally, the measured shape variation was corrected for intraobserver variation to estimate the "real" shape variation. RESULTS: No significant variations in GTV volume were observed. The measured shape variation (including delineation variation) was largest at the tip of the vesicles (SD = 2.0 mm), smallest at the left and right side of the prostate (SD = 1.0 mm), and average elsewhere (SD = 1.5 mm). At the left, right, and cranial sides of the prostate, the intraobserver variation was of the same order of magnitude as the measured shape variation; elsewhere it was smaller. However, the accuracy of the estimated SD for intraobserver variation was about half of the accuracy of the estimated SD for the measured shape variation, giving an overall uncertainty of maximum 0.6 mm SD in the estimate of the "real" shape variation. The "real" shape variation was small at the left, right, and cranial side of the prostate (SD <0.5 mm) and between 0.5 mm and 1.6 mm elsewhere. CONCLUSIONS: We developed a method to quantify shape variation of organs with a complex shape and applied it to a GTV consisting of prostate and seminal vesicles. Deformation of prostate and seminal vesicles during the course of radiotherapy is small (relative to organ motion). Therefore, it is a valid approximation in image-guided radiotherapy of prostate cancer, in first order, to correct only for setup errors and organ motion. Prostate and seminal vesicles deformation can be considered as a second-order effect.

Humans↗

Thromboxane A2-mediated shape change: independent of Gq-phospholipase C--Ca2+ pathway in rabbit platelets.

1. Thromboxane A2 (TXA2) receptor-mediated signal transduction was investigated in washed rabbit platelets to clarify the mechanisms of induction of shape change and aggregation. 2. The TXA2 agonist, U46619 (1 nM to 10 microM) caused shape change and aggregation in a concentration-dependent manner. A forty-times higher concentration of U46619 was needed for aggregation (EC50 of 0.58 microM) than shape change (EC50 of 0.013 microM). The aggregation occurred only when external 1 mM Ca2+ was present, but the shape change could occur in the absence of Ca2+. 3. SQ29548 at 30 nM and GR32191B at 0.3 microM (TXA2 receptor antagonists) competitively inhibited U46619-induced shape change and aggregation with similar potency, showing that both aggregation and shape change induced by U46619 were TXA2 receptor-mediated events. However, ONO NT-126 at 1 nM, another TXA2 receptor antagonist, inhibited U46619-induced aggregation much more potently than the shape change, suggesting the possible existence of TXA2 receptor subtypes. 4. ONO NT-126 (2 nM to 3 microM) by itself caused a shape change without aggregation in a concentration-dependent manner, independent of external Ca2+. Therefore, ONO NT-126 is a partial agonist at the TXA2 receptor in rabbit platelets. 5. U46619 (10 nM to 10 microM) increased internal Ca2+ concentration ([Ca2+]i) and activated phosphoinositide (PI) hydrolysis in a concentration-dependent manner with a similar concentration-dependency. 6. U46619 (3 nM to 10 microM) also activated GTPase concentration-dependently in the membranes derived from platelets. U46619-induced activation of GTPase was partly inhibited by treatment of membranes with QL, an antibody against Gq/11. 7. The EC50 values of U46619 in Ca2+ mobilization (0.15 microM), PI hydrolysis (0.20 microM) and increase in GTPase activity (0.12 microM) were similar, but different from the EC50 value in shape change (0.013 microM), suggesting that activation of TXA2 receptors might cause shape change via an unknown mechanism. 8. U46619-induced shape change was unaffected by W-7 (30 microM), a calmodulin antagonist or ML-7 (30 microM), a myosin light-chain kinase inhibitor, indicating that an increase in [Ca2+]i might not be involved in the shape change. In fact, U46619 (10 nM) could cause shape change without affecting [Ca2+]i level, determined by simultaneous recordings. 9. [3H]-SQ29548 and [3H]-U46619 bound to platelets at a single site with a Kd value of 14.88 nM and Bmax of 106.1 fmol/10(8) platelets and a Kd value of 129.8 nM and Bmax of 170.4 fmol/10(8) platelets, respectively. The inhibitory constant Ki value for U46619 as an inhibitor of 3H-ligand binding was similar to the EC50 value of U46619 in GTPase activity, phosphoinositide hydrolysis and Ca2+ mobilization, but significantly different (P < 0.001 by Student's t test) from the effect on shape change. 10. Neither U46619 nor ONO NT-126 affected the adenosine 3',5'-cyclic monophosphate (cyclic AMP) level in the presence or absence of external Ca2+ and/or isobutyl methylxanthine. 11. The results indicate that TXA2 receptor stimulation causes phospholipase C activation and increase in [Ca2+]i via a G protein of the Gq/11 family leading to aggregation in the presence of external Ca2+, and that shape change induced by TXA2 receptor stimulation might occur without involvement of the Gq-phospholipase C-Ca2+ pathway.

15-Hydroxy-11 alpha,9 alpha-(epoxymethano)prosta-5↗

Selectivity of macaque inferior temporal neurons for partially occluded shapes.

Humans are able to recognize shapes even when they are partially occluded by another pattern. We determined whether inferior temporal (IT) units of awake rhesus monkey remain selective for shapes that are partially occluded by other patterns. In order to link the shape selectivity to shape discrimination, we established that the monkey, like humans, can discriminate partially occluded shapes. We found that IT units are selective for shapes partially occluded by static or moving patterns. The responsiveness, however, decreased with the degree of occlusion. The shape-selective responses to the occluded shapes required longer stimulus durations compared to nonoccluded shapes, matching the better shape discrimination performance at short durations in the no-occlusion compared to the occlusion conditions. Occluder visibility had no effect for shape outlines, indicating that (amodal) shape completion, which is absent when the occluder is invisible, is not necessary for shape selectivity. These data indicate that IT neurons can, indeed, contribute to the invariance of shape perception for changes in retinal input caused by partial occlusion of the shape.

Animals↗

Shape signatures: a new approach to computer-aided ligand- and receptor-based drug design.

A unifying principle of rational drug design is the use of either shape similarity or complementarity to identify compounds expected to be active against a given target. Shape similarity is the underlying foundation of ligand-based methods, which seek compounds with structure similar to known actives, while shape complementarity is the basis of most receptor-based design, where the goal is to identify compounds complementary in shape to a given receptor. These approaches can be extended to include molecular descriptors in addition to shape, such as lipophilicity or electrostatic potential. Here we introduce a new technique, which we call shape signatures, for describing the shape of ligand molecules and of receptor sites. The method uses a technique akin to ray-tracing to explore the volume enclosed by a ligand molecule, or the volume exterior to the active site of a protein. Probability distributions are derived from the ray-trace, and can be based solely on the geometry of the reflecting ray, or may include joint dependence on properties, such as the molecular electrostatic potential, computed over the surface. Our shape signatures are just these probability distributions, stored as histograms. They converge rapidly with the length of the ray-trace, are independent of molecular orientation, and can be compared quickly using simple metrics. Shape signatures can be used to test for both shape similarity between compounds and for shape complementarity between compounds and receptors and thus can be applied to problems in both ligand- and receptor-based molecular design. We present results for comparisons between small molecules of biological interest and the NCI Database using shape signatures under two different metrics. Our results show that the method can reliably extract compounds of shape (and polarity) similar to the query molecules. We also present initial results for a receptor-based strategy using shape signatures, with application to the design of new inhibitors predicted to be active against HIV protease.

Binding Sites↗

Alignment of trans-tibial prostheses based on roll-over shape principles.

The authors examined the roll-over shape alignment hypothesis, which states that prosthetic feet are aligned by matching their roll-over shapes with an "ideal" shape. The "ideal" shape was considered to be the roll-over shape of the able-bodied foot-ankle system. An alignment algorithm and computational alignment system were developed to set trans-tibial alignments based on this hypothesis. Three prosthetic feet with considerably different roll-over shapes were either aligned using the alignment system or not aligned (i.e. used previous foot's alignment), and then were aligned by a team of prosthetists. No significant differences were found between roll-over shapes aligned by the computational alignment system and those based on standard clinical techniques (p = 0.944). Significant differences were found between the "no alignment" shapes and the prosthetist alignment shapes (p = 0.006), and between the "no alignment" shapes and the computational alignment system shapes (p = 0.024). The results of the experiment support the hypothesis that the goal of alignment is to match the prosthetic foot's roll-over shape, as closely as possible, with an "ideal" shape. The hypothesis is also supported by its ability to explain the results of previous studies. Using an "ideal" roll-over shape or surface as a goal for prosthetic alignment could lead to a priori alignment, eliminating the need for alignment hardware in some cases. Being able to build the alignment into a prosthesis without special hardware could be beneficial in low-income countries and in the fabrication of lightweight prostheses for the elderly.

Adult↗

The biomechanical effect and clinical application of a Ni-Ti shape memory expansion clamp.

STUDY DESIGN: The study involves three phases: a clinical study of 30 patients, a biomechanical study to assess the expansion force of a recovering-shape memory expansion clamp, and a biomechanical study using cadaveric specimens to assess the pullout strength of the shape memory expansion clamp as a function of the shape of the clamp. OBJECTIVE: To evaluate the biomechanical effect and clinical application of the shape memory expansion clamp. SUMMARY OF BACKGROUND DATA: The major complication of anterior cervical decompression and fusion was graft dislodgement and pseudarthrosis. Improvement of the shape of bone graft and fusion technique could not eliminate the problem completely. The authors designed the shape memory expansion clamp by using the characteristic of Ni-Ti shape memory alloy and first applied it in an anterior cervical operation. METHODS: The expansion force of recovering of the shape memory expansion clamp was measured in a biomechanical study. Eight fresh human cadaver cervical spine specimens were used to assess the pullout strength of the shape memory expansion clamp as a function of the shape of the clamp. The shape memory expansion clamp had been used to fix rotated circular grafts in 30 cases with cervical spine injuries or cervical spondylosis after anterior decompression. RESULTS: The expansion force of the shape memory expansion clamp in recovery was 4.65-27.96 N, and the pullout strength was 8.82-20.58 N. Bone fusion was achieved in all 30 cases. Dislocation of bone graft, loosening of clamp, or kyphotic deformity had not occurred. CONCLUSION: The expansion force and the pullout strength of the partially recovered shape memory expansion clamp were determined biomechanically. The clinical study demonstrated that the shape memory expansion clamp is safe and effective.

Adult↗

Pose-oblivious shape signature.

A 3D shape signature is a compact representation for some essence of a shape. Shape signatures are commonly utilized as a fast indexing mechanism for shape retrieval. Effective shape signatures capture some global geometric properties which are scale, translation, and rotation invariant. In this paper, we introduce an effective shape signature which is also pose-oblivious. This means that the signature is also insensitive to transformations which change the pose of a 3D shape such as skeletal articulations. Although some topology-based matching methods can be considered pose-oblivious as well, our new signature retains the simplicity and speed of signature indexing. Moreover, contrary to topology-based methods, the new signature is also insensitive to the topology change of the shape, allowing us to match similar shapes with different genus. Our shape signature is a 2D histogram which is a combination of the distribution of two scalar functions defined on the boundary surface of the 3D shape. The first is a definition of a novel function called the local-diameter function. This function measures the diameter of the 3D shape in the neighborhood of each vertex. The histogram of this function is an informative measure of the shape which is insensitive to pose changes. The second is the centricity function that measures the average geodesic distance from one vertex to all other vertices on the mesh. We evaluate and compare a number of methods for measuring the similarity between two signatures, and demonstrate the effectiveness of our pose-oblivious shape signature within a 3D search engine application for different databases containing hundreds of models.

Algorithms↗

Morphometric relationships between tooth and face shapes.

The shape of a patient's face is commonly used as a reference to select the shape of the maxillary central incisors in edentulous patients. The validity of this relationship has not been proved. The objective of this clinical study was to determine whether a relationship exists between maxillary central incisors and face shapes. Casts were made of the maxillas of 50 men and 50 women. A standardized digital photographic procedure was used to record frontal views of each subject's face and of the maxillary central incisors of the dental casts. The shapes of the maxillary central incisors were compared with the face forms. Shape matches were evaluated according to their Hausdorff distance (HDD). The function h(A,B) is called the directed HDD from shape A to shape B (this function is not a true distance). It reflects the distance of the point of shape A that is farthest from any point of shape B and vice versa. The similarity of both shapes is given as a non-negative number. The value 0.0 indicates that the figures are identical (after scaling and shifting). Higher values indicate that shapes differ more substantially. Significant differences on the 5% level were calculated using the non-parametric Mann-Whitney U and Kruskal-Wallis tests. The face shape from the chin margin to the eyebrow line (superior edges of the eyebrows) produced a better match than the one from the chin to the hairline (P < 0.0001). On average, the maxillary central incisors displayed a variability (0.084 +/- 0.028) that was higher by a factor of 1.9 than the face shapes (chin margin to the eyebrow line, 0.045 +/- 0.015). In the interindividual comparison, the shapes of the maxillary central incisors of women displayed a significantly smaller HDD than the ones of the men (P < 0.0001).

Adolescent↗

Discrimination of closed shapes by two species of bee, Apis mellifera and Megachile rotundata.

In the present study, the performance of two bee species, the honeybee Apis mellifera and the leaf-cutter bee Megachile rotundata, in discriminating among various closed (convex) shapes was examined systematically for the first time. Bees were trained to each of five different shapes, a disc, a square, a diamond and two different triangles, all of the same area, using fresh bees in each experiment. In subsequent tests, the trained bees were given a choice between the learned shape and each of the other four shapes. Two sets of experiments were conducted with both species. In the first, solid black shapes were presented against a white background, thus providing a high luminance contrast. In the second, the shapes carried a random black-and-white pattern and were presented 5 cm in front of a similar pattern, thus producing motion contrast, rather than luminance contrast, against the background. The results obtained with the solid shapes reveal that both bee species accomplish the discrimination, although the performance of the honeybee is significantly better than that of the leaf-cutter bee. Furthermore, the effectiveness of the various shapes differs between the two species. However, in neither species is the discrimination performance correlated with the amount of overlap of the black areas contained in the various pairs of shapes, suggesting that, in our experiments, shape discrimination is not based on a template-matching process. We propose that it is based on the use of local parameters situated at the outline of the shape, such as the position of angles or acute points and, in particular, the position and orientation of edges. This conclusion is supported by the finding that bees of both species accomplish the discrimination even with the patterned shapes. These shapes are visible only because of the discontinuity of the speed of image motion perceived at the edge between the shape and the background.

Animals↗

The impact of bladder shape on the ultrasonographic measurement of bladder volume in children.

BACKGROUND: US is used for non-invasive assessment of bladder shape and for calculation of bladder volume. OBJECTIVE: To evaluate the impact of bladder shape on the accuracy of US estimation of bladder volume in children and to calculate formulas for US estimation of volume for different bladder shapes. MATERIALS AND METHODS: US was performed in 146 children (94 girls, 52 boys, age range 9 months to 17 years, median 7.9 years) referred for urodynamic investigation. Three bladder diameters were measured, and bladder shapes were categorized as round, ellipsoid, cuboid, triangular and undefined. Urine was collected, and total bladder volume calculated. Correction coefficients (k) were calculated for the whole sample and for each bladder shape using linear regression analysis. RESULTS: Round bladder shape was present in 23%, 25% showed a cuboid shape, 21% an ellipsoid shape, 25% a triangular shape, and 6% had an undefined shape. Correction (regression) coefficient (k) for the whole sample was 0.66 (SE = 0.011); for round bladder 0.561 (SE = 0.013), cuboid bladder 0.923 (SE = 0.012), ellipsoid bladder 0.802 (SE = 0.006), triangular bladder 0.623 (SE = 0.007), and for undefined shape 0.749 (SE = 0.048). Mean percentage errors when using different correction coefficients were significantly lower than errors when using k = 0.5 applied to our data. CONCLUSIONS: Bladder shape has considerable impact on the accuracy of US estimation of bladder volume in children. Correction coefficients should be used for volume measurements of different bladder shapes.

Adolescent↗

Radiation therapy alone or combined with surgery in the treatment of barrel-shaped carcinoma of the uterine cervix (stages IB, IIA, IIB).

This retrospective analysis reports the results of therapy in 128 patients with carcinoma of the uterine cervix classified as barrel-shaped or expanded cervix (over 5 cm in diameter). Seventy-five percent of the patients were treated with irradiation alone and 25% with combinations of irradiation and surgery. The results of therapy are compared with those observed in 714 patients with non-barrel-shaped carcinoma of the uterine cervix treated with similar techniques during the same period of time. The distribution of histological type of tumor was similar in both groups (90% epidermoid carcinoma, 8% adenocarcinoma, and 2% adenosquamous carcinoma). Approximately 15% of the patients in both groups with Stage IB and 25% with Stage IIA and IIB had positive endometrial curettings (stromal invasion or replacement by tumor only). Thus, the aggressive behavior observed in the barrel-shaped tumors is not a result of endometrial involvement, but to the large volume of tumor present. The actuarial 5-year tumor free survival in Stage IB barrel-shaped cervix was 76% compared to 92% in the non-barrel-shaped lesions. In Stage IIA the 5-year NED survival for patients with barrel-shaped cervix was 60 compared to 80% for the patients with non-barrel-shaped cervix. In Stage IIB the survival rates were 58 and 70%, respectively. A noteworthy finding in this analysis is the high incidence of distant metastases in the patients with barrel-shaped cervix (32% in Stage IB, 40% in Stage IIA, and 32% in Stage IIB) in comparison with patients with non-barrel-shaped tumors (10% in Stage IB, 16% in Stage IIA, and 25% in Stage IIB). The incidence of pelvic failures was comparable in both groups. Higher doses of irradiation resulted in better tumor control, which was comparable to that observed with a combination of irradiation and surgery (conservative hysterectomy). The 5-year survival rate in Stage IB was similar in both the barrel-shaped and non-barrel-shaped tumors treated with irradiation alone or combination irradiation and surgery. In Stage IIA the non-barrel-shaped lesions had the same survival with either treatment technique. In the barrel-shape group, eight patients treated with irradiation alone or survival of 70%, compared to 45% in 24 patients treated with irradiation alone. However, these differences are not statistically significant (p = .50). In eight patients treated with definitive irradiation and a lymphadenectomy and four patients irradiated after an exploratory laparotomy, two major and three minor (grade 2) complications were noted.(ABSTRACT TRUNCATED AT 400 WORDS)

Carcinoma↗

Hair cells of different shapes and their placement along the frog crista ampullaris.

The list of distinguishing morphological features of hair cells includes: Type I and Type II afferent innervation, and length, shapes and arrangements of stereo- and kinocilia. We now add to this list the shapes of the hair cells themselves and their placement within the mechanosensory organ, in this case the semicircular canal. Although hair cells of the crista ampullaris of the frog are only of Type II they may now be further classified into three sub-groups according to shape: club-, cigar- and pear-shaped. The cigar- and club-shaped hair cells are each about 40% while the pear-shaped cells are about 20% of the total numbers of hair cells in the crista. The differently-shaped hair cells also distribute differently along the crista. The cigar- and club-shaped are more-or-less uniformly distributed with somewhat higher concentrations at the ends of the crista than in the center. The pear-shaped hair cells, on the other hand, are mostly concentrated toward the center of the crista. This distribution of the pear-shaped hair cells, and their shape is reminiscent of the distribution of calyceal endings (Type I hair cell) in the cristae of amniotes [Goldberg et al., Hear. Res. 49, 89-102 (1990) in Chinchilla; Fernandez et al., Soc. Neurosci. Abstr. 17, 312 (1991) in Monkey]. There are some quantitative differences between hair cells of the same shape but from different portions of the crista. For instance, pear-shaped hair cells of the center are generally of greater cross-sectional area than those of the ends.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

Surface geometry influences the shape of illusory contours.

Geometric and neural models of illusory-contour (IC) synthesis currently use only local contour geometry to derive the shape of ICs. Work on the visual representation of shape, by contrast, points to the importance of both contour and surface geometry. We investigated the influence of surface-based geometric factors on IC shape. The local geometry of inducing-contour pairs was equated in stereoscopic IC displays, and the shape of the enclosed surface was varied by manipulating sign of curvature, cross-axial shape width, and medial-axis geometry. IC shapes were measured using a parametric shape-adjustment task (Experiment 1) and a dot-adjustment task (Experiment 2). Both methods revealed large influences of surface geometry. ICs enclosing locally concave regions were perceived to be systematically more angular than those enclosing locally convex regions. Importantly, the influence of sign of curvature was modulated significantly by shape width and medial-axis geometry: IC shape difference between convex and concave inducers was greater for narrow shapes than wider ones, and greater for shapes with straight axis and symmetric contours (diamond versus bowtie), than those with curved axis and parallel contours (bent tubes). Even at the level of illusory "contours," there is a contribution of region-based geometry which is sensitive to nonlocal shape properties involving medial geometry and part decomposition. Models of IC synthesis must incorporate the role of nonlocal region-based geometric factors in a way that parallels their role in organizing visual shape representation more generally.

Depth Perception↗