Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Nylon”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11Linked to original sources

Immobilized enzyme nylon tube reactors: creatininase and creatine kinase linked to the pyruvate kinase-lactate dehydrogenase indicator system in the detection of creatinine and creatine.

A four enzyme system catalyzing a sequence of reactions was immobilized onto the inside surfaces of nylon tubes and studied as a possible method of analysis for the first substrate, creatinine in the sequence of reactions. The system was first studied in solution as a guide to optimizing conditions for preparation and use of the immobilized enzyme nylon tube reactors. The scope and limitations of this approach to routine analysis is discussed.

Amidohydrolases↗

HLA-DR typing: a comparison between nylon wool adherence and T cell rosetting in the isolation of B cells.

A comparison was made between two different methods of B cell isolation, nylon wool adherence versus SRBC rosetting in terms of the technical ease of B cell purification and the reproducibility of DR phenotyping. It was found that B cells isolated by either method from 30 randomly selected donors gave equivalent results in the determination of DR phenotypes. Due to its simplicity and reliability, nylon wool adherence may be preferred over the SRBC rosette method for the routine phenotyping of B cells.

Animals↗

Electrotransfer of proteins following polyacrylamide gel electrophoresis. Nitrocellulose versus nylon membranes.

We found that some plasma proteins such as haptoglobin (Mr 200,000) and alpha 1-acid glycoprotein (Mr 40,000) do not bind at all to nitrocellulose membranes in classical transfer conditions. In contrast, these proteins can be clearly identified when a charged nylon membrane is disposed on the anodal side of the nitrocellulose membrane. Several factors which are important in modifying the adherence between proteins and the blotting membrane have been studied. They are not directly related to the molecular weight of the protein considered but also include the presence of organic solvents in the buffer systems, the pore size of the membrane and the degree of reduction and/or glycosylation of the protein. The eventuality of decreased or absent identification of some antigens on nitrocellulose membranes stresses the importance of controls using nylon membranes.

Blood Proteins↗

Gingival response to silk, cotton, and nylon suture materials.

Silk, cotton, and nylon suture materials were implanted in the tunica propria of the gingiva in seven adult rhesus monkeys. The histologie study of twenty-four biopsy specimens indicated that there was neither an increase in the vascular permeability nor a leukocytic margination and migration into the tissues adjacent to the suture materials. However, there was a variable histiocytic reaction, with multinucleated cell formation. This reaction was quite intense with cotton, less intense with silk, and practically absent with nylon. The greater cellular response to cotton was probably due to its more active capacity for modifying the internal biologic medium of the gingvia.

Animals↗

The use of nylon pouches to prevent cellular attachment to implanted materials.

A nylon pouch system has been developed to permit the in vivo exposure of implantable materials to tissue fluids without complications arising from cellular attachment or from the bacterial attack. SEM observations have indicated that the pouches were effective in reducing the ingress of bacteria as well as reducing, and in some cases eliminating, cell infiltration through their mesh structure. Over a 7 d implantation period, the exterior surfaces of the nylon pouches were heavily infested with microorganisms but there was minimal growth of bacteria within the pouches. Non-infected pouches that were implanted for up to 25 wk showed heavy deposits of cellular matter on the external surfaces of the pouches and minimal deposits within the pouches.

Absorption↗

Hydroxyapatite-mediated transfer of DNA from diluted solutions to nitrocellulose or nylon membranes.

Transfer of DNA (from 0.1 to 10 micrograms) from diluted solutions of variable volumes (1-10 ml) and various composition (2 M NaCl; 4 M LiCl, 8 M urea; 4 M CsCl; 20% sucrose) to nitrocellulose or nylon membranes was achieved with the use of hydroxyapatite. This absorbent that binds nucleic acids effectively and independently of ionic strength and composition of solution (except for chelators and phosphate ions) easily dissolves in small volumes of acids (for example, in 10% TCA). This phenomenon provides the opportunity to deliver the acid-insoluble precipitates to membrane filters. After alkaline denaturation on the filter followed by a fixation step (baking or UV irradiation for nitrocellulose or nylon filters, respectively), DNA hybridizes effectively with nick-translated DNA probes. The method is simple, reproducible, sensitive, and useful for working with diluted DNA solutions containing interfering substances.

Animals↗

Colony hybridizations using nylon membranes and RNA probes--an improved method for screening bacterial clones containing bluetongue virus genome.

Bluetongue virus (BTV) total genomic and isolated individual segment dsRNAs end-labeled with 32P were successfully used as probes in colony hybridization to detect clones of BTV genomic material. The RNA probes were highly specific for cloned BTV genomic material. DNA probes, however, gave false positive results. DNA from bacterial clones was fixed to nylon and nitrocellulose membranes. The hybridized nylon membranes could be stripped of probe and reprobed at least 6 times without loss of signal strength.

Animals↗

Evaluation of biofilm formation on nylon sutures removed from clinically noninfected eyes after cataract surgery.

PURPOSE: To determine the presence of bacterial biofilm on nylon sutures removed from clinically noninfected eyes after cataract surgery. SETTING: The Eye Institute, Tan Tock Seng Hospital, Singapore, Singapore. METHODS: Sutures were removed from 10 eyes after cataract surgery at different time periods. Immediately after removal, the sutures were fixed and dehydrated. All sutures were viewed by scanning electron microscopy, and 6 were also viewed by transmission electron microscopy (TEM). RESULTS: There was no evidence of bacterial biofilm formation on the nylon sutures. Significant cellular debris was seen, mainly at the knots. Clusters of coccoid-shaped structures were visible; however, examination by TEM showed they were not bacteria. CONCLUSION: There was no evidence of biofilm formation on sutures removed after cataract surgery from clinically noninfected eyes.

Aged↗

Combinatorial screening employing nylon loops and micro-X-ray powder diffraction.

A combinatorial screening method is described that employs nylon loops and micro-X-ray powder diffraction. The nylon loops are used to position the sample in a three-circle X-ray diffractometer in such a way as to allow for Gandolfi-like scans. These scans maximize mechanical tumbling of the sample, which in turn results in higher quality data. The diffractometer utilizes a pinhole source and two-dimensional area detection for rapid data collection. The method can be readily automated by employing single-crystal screening procedures. The combinatorial analysis of the three known polymorphs of D-mannitol is discussed and a simple procedure to produce all three polymorphs from the same starting solutions is presented.

Combinatorial Chemistry Techniques↗

Effectiveness of suturing training with 10-0 nylon under fixed and maximum magnification (x 20) using desk type microscope.

BACKGROUND: Microvascular anastomosis using 10-0 nylon needs a higher level of technical dexterity compared with routine neurosurgical maneuvers. Although this technique remains an important part of treating complex intracranial aneurysms or cerebrovascular disease, the surgeon's clinical experience in using this technique is not so common. METHODS: To improve dexterity and maneuverability in the limited clinical case volume, we developed an easily accessible training system, using commercially available desk type microscope and simply suturing neighboring fibers of the gauze with 10-0 nylon under fixed and highest (x 20) magnification. RESULT: This training system is somewhat of a drawback compared to the simulation of a real clinical setting. However, because of the extremely easy availability and accessibility of the dark type microscope repeated training and the accumulation of more than 10000 stitches, on average, was accomplished. This resulted in a steep learning curve of the technique. CONCLUSION: For residency and post-residency year young neurosurgeons, who need to brush up their skills due to lower surgical case volume compared with what senior neurosurgeons have experienced this easily available training would contribute to establishing daily and long-lasting microsurgical practice.

Humans↗

Comparison of single rubber-nylon balloon and double polyethylene balloon valvuloplasty in 94 patients with rheumatic mitral stenosis.

To compare the single rubber-nylon balloon and double polyethylene balloon techniques, 94 patients with rheumatic mitral stenosis underwent percutaneous transseptal balloon mitral valvuloplasty between November 1985 and September 1988. The single balloon technique was used in 73 patients and the double balloon technique was used in 21. The two groups were similar in age, weight, severity of the lesion, and cardiac functional status. The mean mitral valve diastolic gradient decreased from 17.9 +/- 6.5 to 2.9 +/- 3.1 mm Hg (p less than 0.001), 18.5 +/- 6.7 to 5.8 +/- 3.1 mm Hg (p less than 0.001), and 18.1 +/- 5.9 to 3.2 +/- 3.7 mm Hg (p less than 0.001) in the single balloon group, double balloon group, and the entire series, respectively. The final mitral diastolic gradient in the single balloon group was lower than in the double balloon group (p less than 0.05). Complications in the single balloon group were lower than in the double balloon group. Additional advantages of single over double balloon technique were easier maneuverability and higher success rate. The initial and long-term follow-up results confirmed the earlier impressions that percutaneous transseptal balloon mitral valvuloplasty is an effective and safe nonsurgical method of treatment for rheumatic mitral stenosis, and the single rubber-nylon balloon technique is at least as effective as, if not superior to, the double polyethylene balloon technique.

Adolescent↗

Nylon brush improves collection of cervical cytologic specimens.

A prospective, randomized study was performed to compare the efficacy of a combined endocervical and ectocervical nylon brush with the cotton-tipped swab and wooden spatula for obtaining cervical cytologic specimens. Strict objective criteria were used to determine the adequacy of Papanicolaou smears on the basis of the number of cells present. The two methods were equally effective in collecting ectocervical smears. However, 96% of endocervical smears obtained with the nylon brush contained greater than 50 cells, compared with 58% of swab and spatula smears. Only 1.4% of brush samples contained no endocervical cells, versus 19% of swab and spatula smears. The presence of endocervical cells confirms adequate sampling of the transitional zone. Use of the cytologic Papanicolaou brush may result in fewer false negative and inadequate Papanicolaou smears.

Adolescent↗

Supercritical fluid extraction of nylon 6,6 oligomers and their characterization via liquid chromatography coupled with mass spectrometry.

This research extends previous studies regarding the application of supercritical fluid extraction (SFE) for the analysis of oligomers from nylon 6,6 fibers. The effects of CO2 pressure, extraction temperature, CO2-modifier percentage, static extraction time and dynamic extraction time on the SFE efficiency of nylon 6,6 oligomers were examined. Results from the SFE methods for oligomer extractions were compared to results from conventional solvent extraction. The extracted oligomers were identified by high-performance liquid chromatography (HPLC) with coupled on-line atmospheric pressure chemical ionization mass spectrometry and HPLC fractionation coupled with off-line liquid secondary ion mass spectrometry.

Chromatography, High Pressure Liquid↗

Applications of nylon membrane arrays to gene expression analysis.

Gene expression analyses by hybridization of probes derived from mRNA to cDNA targets arrayed on a nylon membranes have been performed with increasing frequency and success over the last decade. While the initial costs of generating arrays are moderately high, they are now available commercially as complete packages which include the membranes and associated image analysis software for acquisition and processing of the data. Arrays can be used to generate information concerning the expression of mRNA from cells treated with various agents or from different tissues, e.g. comparing diseased with normal controls. To date, many groups, including immunologists, have used this technology to examine gene expression within their area of biological interest. The main characteristic of these systems is the large amount of data generated, since the expression of many thousands of genes are measured in parallel. The main practical issues are sensitivity of detection, reproducibility, comparability with other systems (e.g. Northern blots) and processing of data. Some of the significant applications of nylon array technology to date are reviewed in this chapter, and with these issues in mind, we include a discussion of our own experiences in this area.

Arthritis, Rheumatoid↗

Nylon fibers as supporting media in anaerobic hybrid reactors: it's effects on system's performance and microbial distribution.

The performances of three anaerobic hybrid reactors with various nylon fiber densities per packed bed volume (33, 22, and 11 kg/m(3) in R1, R2, and R3, respectively) as supporting media were evaluated through their ability to remove organic compounds in cassava starch wastewater. In addition, the distributions of non-methanogenic and methanogenic population in the reactors were investigated. During a 6-month operation, the organic loading rate was increased in stepwise from 0.5 to 4.0 kg COD/m3/day and the hydraulic retention time (HRT) shortened to 5.4 days. The COD removal efficiency was more favorable in R1 (87%) and R2 (84%) than in R3 (70%). The total biomass in the reactors with greater nylon fiber densities was also higher and increased from 20.4 to 67.3 g VSS and to 57.5 g VSS in R1 and R2, respectively. When the HRT was further shortened to 3 days, however, the efficiency of both reactors demonstrated a declining trend and reached 74% in R1 and 61% in R2. The distribution of microbial populations involved in the reactors was determined using the Most Probable Number technique. The result showed the lowest number of methanogens in R3 which correlated well to its relatively low efficiency. The number of non-methanogens in all reactors was, nonetheless, comparable. By shortening the HRT to 3 days, the methanogenic population in R2 diminished in both attached and suspended biomass whereas a slight reduction was detected only in the attached biomass of R1.

Bacteria, Anaerobic↗

Nylon in the anterior chamber.

The extensive use of nylons as iris fixation sutures and intraocular lens loops has resulted in complication rates of between 0.5 and 19%, depending on the series and postoperative time of examination. The primary reason for failure is chemical degradation of the nylon, particularly in the area posterior to the iris. The major clinical consequence of broken fixation sutures is corneal epithelial edema which is usually reversible if the touching suture is removed.

Chemical Phenomena↗

In vitro cytotoxicity and teratogenicity of norethisterone and levonorgestrel released from hollow nylon monofilaments.

Direct delivery of progestogens to the uterus may be of use in the treatment of dysfunctional uterine bleeding and the sequelae of the menopause as it has the potential to overcome the problems of systemic administration. This study characterised the release of norethisterone and levonorgestrel into an aqueous medium from hollow nylon fibres with dimensions suitable for easy insertion through the post-menopausal cervix. Cell culture techniques were used to assess potential cytotoxic and teratogenic effects. The results demonstrated that the hollow fibres released norethisterone and levonorgestrel at mean rates of 0.5 and 0.6 micrograms/day over 14 days, respectively. There were indications, however, that both steroids were toxic to endometrial cells at concentrations of approximately 5 micrograms/ml, and both drugs showed signs of potential teratogenicity at 10 micrograms/ml. Delivery of the same doses of norethisterone using the hollow fibres reduced the effects on the endometrial and fetal cells. Delivery of levonorgestrel from the hollow fibres had no effect on the endometrial cell toxicity but potentiated the effects on the fetal cells. These results suggest that the hollow nylon fibres may be of use for the delivery of norethisterone to the uterus but that they are inappropriate for the delivery of levonorgestrel.

Abnormalities, Drug-Induced↗

The effects of bovine serum albumin and the chemotactic peptide formyl-methionyl-leucyl-phenylalanine on the adherence of guinea pig polymorphonuclear leukocytes to nylon fiber columns.

Glycogen-induced guinea pig polymorphonuclear leukocytes were passed over nylon fiber columns and adherent and nonadherent fractions were quantitated by determination of hexosaminidase activity after lysis with Triton. Bovine serum albumin reduced the number of adherent cells at 37 degrees C as well as 4 degrees C, after fixation of the cells with glutaraldehyde, and in the absence and presence of EDTA. The chemotactic peptide N-formyl-methionyl-leucyl-phenylalanine increased the adherent cell fraction at 37 degrees C, but failed to do so at 4 degrees C, after glutaraldehyde fixation and in the presence of 10 mmol/EDTA. Since metabolic inhibitors had no effect on the rate of adherence it is suggested that increased cell deformability is responsible for chemotactic factor-induced increased cell attachment to nylon fibers.

Animals↗